24 VDC - Lumino Lighting · VECA-CA025-R1 250mm Inter connector lead M&F Standard 2 Pin...
Transcript of 24 VDC - Lumino Lighting · VECA-CA025-R1 250mm Inter connector lead M&F Standard 2 Pin...
For further help regarding installation visit lumino.lighting
OPTIONAL ACCESSORIES
VECA-CA025-R1 250mm Inter connector lead M&F Standard 2 PinVECA-CA100-R1 1000mm Inter connector lead M&F Standard 2 Pin
ESSENTIAL ACCESSORIES
IMV10S-R1801
31
23 x per metre
24 VDC
Max screwGauge No.4 4
CLICK
a. c.b.
• Damage will be caused by incorrect input voltage or short circuit• Ensure access and sufficient free moving air space around products and drivers• Products and power supply gear must not be live wired• Protect products from dust & paint during installation and use• Shielded pair of cables will be required for dimming control signal if applicable• Plan for loads, driver locations, dimming and suitable cable prior to installing• For technical assistance contact your local Lumino distributor.• Use only with class 2 power unit to UL 1310 standard• Use only with maximum output 24VDC voltage Class 2 power unit
!
TURN OFF POWER!COUPER LE COURANT!STROM ABSHALTEN!CORTE CORRIENTE!
CHECK THE WALL!VËRIFIER LE MUR!DIE WAND ÜBERPRÜFEN!COMPRUEBE LA PARED!
Check!
V10SVECTOR INSTALLATION MANUAL
V10S-MA620-R1 V10S Rotation Mount PC White (x20)V10S-MA600-R1 V10S Rotation Mount PC White (x100)V10S-MA900-R1 V10S Rotation Mount PC White (x500)
For further help regarding installation visit lumino.lighting
Straights / Corners / Curves Concealed Coving
50mm
min.
120m
mm
in.
40°
175
140 80
475
40°
175
140
20°
70 30°
70
Solidedge / Shelving
V10SVECTOR INSTALLATION MANUAL
V10SVECTOR WIRING GUIDE
For further help regarding installation visit lumino.lighting
24VDCDRIVER
See guide forcable length
VectorVectorVector
<6W/m up to 12m<12W/m up to 6m
Standard wiring arrangementMAX CABLE LENGTH GUIDE 24VDC power supply*
0.3mm²22AWG
0.8mm²18AWG
1.3mm²16AWG
2.0mm²14AWG
VectorLength
VectorCurrent
VectorPower
32m16m10m8m6m5m4m3m3m2m2m1m
50m50m50m50m42m36m31m27m23m20m18m16m
50m50m50m50m50m50m45m41m37m33m30m28m
50m50m50m50m50m50m50m50m50m50m47m44m
1m / 3.3’2m / 6.6’3m / 9.8’4m / 13.1’5m / 16.4’6m / 19.7‘7m / 23’ 8m / 26.2‘9m / 29.5’10m / 32.8’11m / 36’12m / 39.3’
6W/m 1.7W/ft6W/m 1.7W/ft6W/m 1.7W/ft6W/m 1.7W/ft6W/m 1.7W/ft6W/m 1.7W/ft6W/m 1.7W/ft6W/m 1.7W/ft6W/m 1.7W/ft6W/m 1.7W/ft6W/m 1.7W/ft6W/m 1.7W/ft
0.250.500.751.001.251.501.752.002.252.502.753.00
16m8m5m3m2m1m
50m50m36m27m20m16m
50m50m50m41m33m28m
50m50m50m50m50m44m
1m / 3.3’2m / 6.6’3m / 9.8’4m / 13.1’5m / 16.4’6m / 19.7’
12W/m 3.7W/ft12W/m 3.7W/ft12W/m 3.7W/ft12W/m 3.7W/ft12W/m 3.7W/ft12W/m 3.7W/ft
0.501.001.502.002.503.00
*Cable lengths are based on average resistance for typical copper cables. Cable characteristics may vary acording to manufacturer, temperature, copper purity, connections etc.
• Installation must be carried out by qualified electrician.
• Electrical work to be conducted in accordance with local regulations.
• Power must be disconected prior to installation work.
• Ensure free-moving air space around leds and drivers.
• Protect the leds from dust and paint during installation and use.
• Plan for loads, driver locations, cables sizes etc prior to installation.
• Shielded control pair required for dimming signal wires.
• Incorrect voltage, reverse polarity or short circuit will cause damage.
Installers must ensure voltage drop does not exceed 5%.
Driver protection circuitry must not be relied upon to protect secondary 24VDC electrical circuits from damage caused by overcurrent or short circuit. DC fuses or DC electronic circuit breakers are recommended to provide additional protection.
Installers must ensure EMI emissions do not exceed local regulated limits.
Shielded cables and ferrite coils can be used where applicable. Vector interconnector cables are 22AWG.
Reduce max. cable lengths by 10% if dimming.
EMI Emission24 VDC
Use 24VDC drivers with overload and short-circuit protection. Rate drivers for at least 10% above load.
USA & Canada:Use only with Class 2 power unit to UL1310 standard. Use only with maximum output 24VDC voltage Class 2 power unit.
Constant voltage LED drivers can have high inrush current at power-on. Driver inrush current can be many times the normal operating current. Use a suitable MCB. Type C MCBs are normally suitable but if inrush current is a persistant problem an inrush suppressor may be required.
V10SMAX LED LENGTH GUIDE (EXCLUDING CABLE)
lumino.lighting/support
6W/m1.8W/ft
12W/m3.7W/ft
9m / 29’16m / 52’24m / 78’
4.5m / 15’8m / 26‘12m / 39’
P24-060-DALP24-100-DALP24-150-DAL
TRIAC DIMMING
0-10V DIMMING
DALI DIMMING
6W/m1.8W/ft
12W/m3.7W/ft
16m / 52’32m / 105’
8m / 26‘16m / 52’
P24-100-PHP24-200-PH
6W/m1.8W/ft
12W/m3.7W/ft
9m / 29’16m / 52’19m / 62’32m / 105’
4.5m / 15‘8m / 24’9.5m / 31’16m / 52’
P24-60-D10P24-100-D10P24-120-D10P24-200-D10
continue up to max. cable and load limits24VDCDRIVER
Max Total LED Length (see table)
VectorVectorVector VectorVectorVector
120VAC / 230VACTRIAC leading-edgephase cuttingdimmed supply
0-10v dimming signal input
continue up to max. cable and load limits24VDCDRIVER
Max Total LED length (see table)
VectorVectorVector VectorVectorVector
DALI dimming signal input
continue up to max. cable and load limits24VDCDRIVER
Max Total LED length (see table)
VectorVectorVector VectorVectorVector
Total LED LengthTriac Driver
Total LED Length0-10V Driver
Total LED LengthDALI Driver
*See guide forcable length
*See guide forcable length
*Cable length from Driver to LED, see Max Cable Length Guide.’
*See guide forcable length
<6W/m up to 12m<12W/m up to 6m
<6W/m up to 12m<12W/m up to 6m
<6W/m up to 12m<12W/m up to 6m
<6W/m up to 12m<12W/m up to 6m
<6W/m up to 12m<12W/m up to 6m
<6W/m up to 12m<12W/m up to 6m