    Electrical Test Equipment from Beha-Amprobe

    Beha-Amprobe two of the most famous brands

    in the US and Germany have now incorporated

    Robin Installation testers within the range

    available to customers in the UK and Ireland.

    Beha-Amprobe offers wide range of cost-

    effective, innovative test equipment specically

    designed to make the electrician’s job faster

    and easier. This includes the Robin range of

    single, dual and multifunction 17th Edition

    Installation Testers specically designed for

    testing xed installations in the UK and Ireland.

    Beha-Amprobe products are sold and supported

    by a wide range of dealers and are backed up

    by a professional support service. The vast

    array of Beha-Amprobe products, plus the

    incorporation of the Robin electrical range,means the UK electrician has a one stop shop for

    quality, value-priced products which include 17th

    Edition Installation Testers, Voltage Detectors,

    Multimeters, Clamp Meters, Thermometers

    and Two Pole Testers - one of the largest ranges

    available to the electrical contractor and engineer.

    Single & Dual FunctionInstallation Testers . . . . . . . . . . . . . . . 3

    Portable Appliance Testers . . . . . . . . 7

    Electrical Testers . . . . . . . . . . . . . . . . 9

    Clamp-on Meters . . . . . . . . . . . . . . . 12

    Digital Multimeters . . . . . . . . . . . . . . 15

    Temperature Measurement . . . . . . . 18

    Other Test Equipment . . . . . . . . . . . 21

  • 8/19/2019 21128 Robin Shortform Catalogue 2014 v7

    3/28

  • 8/19/2019 21128 Robin Shortform Catalogue 2014 v7

    4/28

    n Three levels of trip currents (x1/2, x1, x5) for complete

    range of testing applications

    - Fast Trip Function (KMP7020) 

    - Ramp Test (KMP7021)

    n 3-LED proper connection indicator

    n Phase switch selection 0° and 180° for

    positive and negative semi-cycle testing

    n Designed to allow testing to BS7671

    IEE 17th Edition regulations

    n Large display

    n Safety CAT III 300V

    n Non Trip Loop test

    n Fast testing

    n Instant reading

    n 20, 200 & 2000Ω Loop measurement ranges

    n PSC measurement up to 20kA

    n Displays mains voltage before test

    n Instant correct wiring status check 

    n Designed to allow testing to BS7671

    IEE 17th Edition regulations

    n

     Backlight displayn Low Battery Indication

    n CAT III 300V

    KMP7020/KMP7021Digital RCD Tester

    KMP7030Loop Impedance Tester

    Robin-Amprobe RCD testers are simple to use devices

    designed to check for correct operation of RCD devices.

    They feature three levels of trip currents with either Fast Trip

    or Ramp Test for complete range of testing applications.

    A residual-current device (RCD) disconnects a circuit whenever

    the electric current is not balanced between the energised

    and the neutral conductors. The imbalance indicates that

    there is a leakage current outside of the system sometimes

    caused by the person accidentally touching the energised part

    of the circuit, and sometimes by lack of sufficient insulation

    (excessive moisture or worn out, poor quality insulationmaterials). RCDs are designed to disconnect quickly to mitigate

    the harm caused by such shocks and to avoid current leaks

    which may lead to fire and other dangerous situations.

    Loop testing is a quick, convenient, and highly specific method

    of evaluating an electrical circuit for its ability to engage

    protective devices (circuit breakers, fuses, RCD’s). A “loop” is

    defined by including unsuspected elements, where current has

    found parallel paths to ground. A ground loop determines the

    effectiveness of protective devices, therefore it is crucial to be

    able to measure it, in order to detect and correct problems.

    KMP7020

    KMP7021

    4

  • 8/19/2019 21128 Robin Shortform Catalogue 2014 v7

    5/28

       S   i  n  g   l  e -   F

      u  n  c  t   i  o  n

       I  n  s  t  a   l

       l  a  t   i  o  n   T

      e  s  t  e  r  s

    KMP7010Ground Resistance Tester

    Robin-Amprobe Ground Resistance Testers are designed

    to measure resistance of the grounding systems to verify

    that the system has low enough resistance to provide

    protection for people, equipment and structures.

    A properly functioning grounding system is a critical safety

    feature of an electrical system. It is used to mitigate the risk

    when exposed metal parts come in contact with dangerous

    voltages in the event an installation fails. The building

    structures are protected by grounding systems to divert

    energy of lightning strikes straight to ground. Connections to

    ground limit the build-up of static electricity when handling

    flammable products or when repairing electronic devices.

    n Measures Earth ground resistance -

    3 point (fall of potential) or 2 point testsn Voltage measurement prevents false measurementsn Test leads, auxiliary electrodes are

    included for a complete instrumentn Built-in memory to store 20 measurementsn Designed to allow testing to BS7671 IEE 17th

    Edition regulationsn Safety CAT III 600V

    KMP7036Insulation-Continuity Tester

    n

     Tests insulation of wires, cables,transformers and electrical motors

    n Selectable test voltages 250V, 500V and 1000Vn Test button hold to perform the

    Dielectric Absorption Ratio Testn Continuity test @ 200mA short-circuitn Designed to allow testing to BS7671

    IEE 17th Edition regulationsn Built in voltmeter and red light warning

    for live circuit indicationn Automatic discharge of test object after

    completion of measurementn Test lead resistance zero facilityn Safety CAT III 600V

    The Robin-Amprobe Insulation-Continuity Tester is designed

    to diagnose and prevent the breakdown of the insulation in

    various parts of the electrical system such as wires, transformers

    and motors. The KMP7036 features three testing voltages

    covering wide range of commercial and residential applications.

    The quality of insulation is critical to assure proper,

    uninterrupted and safe functioning of electrical circuits.

    17A

    Kits - Single Function Installation Testers

    KMP7036 Insulation Tester

    KMP7036 Insulation TesterCarry case includedwith both kits

    KMP7030 Earth Loop Impedance Tester

    KMP7030 Earth Loop Impedance Tester

    KMP7020 RCD Tester

    KMP7021 RCD Tester

    +   +

    17B

    +   + 5

  • 8/19/2019 21128 Robin Shortform Catalogue 2014 v7

    6/28

    KMP7100Dual Function Loop /

    RCD Tester

    Robin-Amprobe KMP7100 is a dual function installation

    tester combining both Earth Loop Impedance tester and

    RCD tester in one compact easy to use package. Ideal for

    use with the Robin Amprobe 7036 Insulation tester.

    n Loop Functions

      - Non Trip Loop test

      - Fast testing  - 20, 200 & 2000Ω Loop measurement ranges

      - PSC measurement up to 20kA

      - Displays mains voltage before test

      - Instant correct wiring status check 

    n RCD Functions

      - Three levels of trip currents (X1/2, X1, X5)for complete range of testing applications

      - Phase switch selection 0° and 180° for

    positive and negative semi-cycle testing

      - Test pulse sensitive (DC) RCDs

      - Auto RCD test

      - Selectable 25V/50V fault voltage for RCD test

    n Designed to allow testing to BS7671

    IEE 17th Edition regulations

    n Displays mains voltage before test

    n “Test lock” for automatic start testwhen connected to circuit

    n Dual measurement result display - primary display for

     RCD/Loop measurement, secondary

    display for circuit voltage

    n Built-in Volt meter

    n Safety CAT III 300V

    KTS1625Digital Multifunction Tester

    (Insulation / Continuity / Loop / RCD / Voltage

    Safety and performance are two most critical requirements

    for every electrical system. The quality of insulation, properly

    working grounding system and active protection are to

    assure safety of people, electrical systems and buildings

    against electrocution, fire, and other equipment damage.

    Robin-Amprobe KTS1625 tester verifies the safety of electrical

    installations in domestic, commercial and industrial applications. It

    can ensure that fixed wiring is safe and correctly installed to meetthe requirements of BS7671 IEE 17th edition wiring regulations.

    n Continuity Functions

      - Continuity resistance @ 200mA

    n Insulation Function

      - Selectable test voltages 250V, 500V & 1000V

    n Line / Loop Impedance Functions

      - Prospective earth fault current

      - Prospective short-circuit current

      - Non Trip Loop test

    - Fast testing

    n RCD Functions

      - Three levels of trip currents (X½, X1, X5)

    for complete range of testing applications

      - Phase switch selection 0° and 180° for

    positive and negative semi-cycle testing

      - RCD ramp test

      - Tests time delayed RCDs (S-type)

      - Test pulse sensitive (DC) RCDs

      - Auto RCD test

    n Designed to allow testing to BS7671

    IEE 17th Edition regulations

    n

     Voltage and frequency measurementsn Instant correct wiring status check 

    n Dual measurement result display

    n Large, backlit display

    n Low battery indication

    n Safety CAT III 300V

    Accessories for Robin-Amprobe testersERT2 Earth resistance kit

    SL17B Standard test lead set e/leads, probes,

    alligator clips and mains lead

    TP1625 Test probe with remote test button for KTS1625

    SL7030 Standard test lead set for KMP7030

    KP1700 Single function tester kit carry bag

    SL17E Fused test lead set w/probes, al ligator clips

    6

  • 8/19/2019 21128 Robin Shortform Catalogue 2014 v7

    7/28

    Portable Appliance Testers

    Robin-Amprobe Portable Appliance Test –

    Built Tough to Test the Safety and Integrity

    of Electrical Appliances

    7

  • 8/19/2019 21128 Robin Shortform Catalogue 2014 v7

    8/28

    GT-400-UKPortable Appliance Tester

    The new Robin-Amprobe GT-400-UK Portable

    Appliance Tester, is a light- weight, portable appliance

    tester that tests the integrity of electr ical devices.

    Developed for the commercial electrician or facilities

    maintenance persons to carry out a wide variety of

    safety measurements of electrical appliances, the

    GT-400-UK is extremely easy to use. Measuringearth ground and insulation resistance, as well as

    current, the GT-400-UK will ensure safety,

    functionality and compliance of regulatory standards.

    n Intuitive and simple to use with no training required

    n Easily portable for on the go testing

    n Fast answers - Instantly measures safety and

    integrity of electrical appliances

    n Measures earth bond resistance

    n Insulation resistance measurements up to 500V

    n Substitute Leakage Current measurements

    n Protective Conductor Current measurements

    n Rugged with high quality construction for years of service

    n Tests appliances for safety in accordance

    with the IET Code of Practice, EN 61010 Safety Standards

    8

  • 8/19/2019 21128 Robin Shortform Catalogue 2014 v7

    9/28

    The range of Beha-Amprobe Electrical Testers

    include Non-contact & Two Pole Testers.

    Electrical Testers

    9

  • 8/19/2019 21128 Robin Shortform Catalogue 2014 v7

    10/28

    VP-720-EVoltage Tester LCD with Phase Rotation

    Additional Features

    n Vibration function

    n Test of 30mA RCD by both push buttons,

    avoids unintended tripping of RCD

    n Torch function via white LED

    n Quick single-hand test on 19 mm

    contact distance sockets

    n Built and certified according to latest voltage tester

    standard EN-61243-3:2010, DIN VDE 0682-401:2011

    n Voltage test via LCD-Display and

    LED-Bargraph (12-690V AC/DC)

    n Single pole test for phase polarity

    n Continuity test

    n Two pole phase indication,

    no third hand required

    n Switchable Load of 140 W

    with two push buttons,

    tripping of 30 mA RCD

    n Automatic AC/DC voltage

    indication, indication of polarity

    n IP 64, splash-proof anddust-tight protection

    n Probe tip protection for reducing

    the danger of injuries (attached

    to lead - permanently available)0

    VP-700-EVoltage Tester with

    Rotary Field Indicator

    nVoltage test (12-690V AC/DC)

    nTwo pole phase rotation

    indication, no third hand required

    nIndication of polarity

    nSwitchable Load of 140 W

    with two push buttons,

    tripping of 30 mA RCD

    nIP 64, splash-proof anddust-tight protection

    nProbe tip protection for reducing

    the danger of injuries (attached

    to lead - permanently available)

    Additional Features

    nNo unawared tripping of RCD

    nNo battery required

    nQuick single-hand on 19 mm contact distance outlets,

    without removing test probe from instrumentnBuilt and certified according latest voltage tester

    standard EN-61243-3:2010, DIN VDE 0682-401:2011

    VP-710-EVoltage Tester with

    Phase Rotation

    Additional Features

    n Quick single-hand on 19 mm contact distance outlets,

    without removing test probe from instrument

    n Torch function via white LED

    n Built and certified according latest voltage testerstandard EN-61243-3:2010, DIN VDE 0682-401:2011

    nVoltage test (12-690V AC/DC)

    nTwo pole phase rotation indication,

    no third hand required

    nSingle pole test for phase polarity

    nContinuity test

    nSwitchable Load of 140 W with two

    push buttons, tripping of 30 mA RCD

    nAutomation AC/DC voltage

    indication, indication of polarity

    nIP 64, splash-proof and

    dust-tight protection

    nProbe tip protection for reducing

    the danger of injuries (attached

    to lead - permanently available)

  • 8/19/2019 21128 Robin Shortform Catalogue 2014 v7

    11/28

       V  o

       l  t  a  g  e   T

      e  s  t  e  r  s

    11

    VP-440 RTNon-contact Voltage

    Tester

    n Non-contact, optical

    detection of AC voltages

    n 50-1000V AC

    n Fast, accurate detection of

    cable breaks in open-ended

    cables, e.g. cable drums

    n Compact, handy design

    that fits in any pocket

    n Wide range of applications

    in trade and industry

    2050-DVOLTfix plus – non-contactvoltage tester

    VP-450-ENon-contact VoltageTester

    Non-contact, optical and acoustic

    detection of AC voltages. Fast, exact

    location of line breaks in cables lying

    open e.g. cable drums. Reliable, automatic

    self-test at start-up of the equipment

    by visual standby display. Compact,

    handy design, which fits in any pocket.

    n CAT III 600 V

    n Optical and acoustic detection

    n Integrated flashlight

    n Compact, handy design

    n Optical standby display.

    n Non-contact, optical and acoustic

    detection of AC voltages

    n 50-600V AC

    n Fast, accurate detection of

    cable breaks in openended

    cables, e.g. cable drums

    n Reliable, automatic self-

    test of activated device with

    optical readiness indicator

    n Compact, handy design

    that fits in any pocket

    n Wide range of applications

    in trade and industry

    Additional Features

    n On/off switch

    nFast and accurate locating of

    fuses and assignment to circuits

    nLocating and tracing

    of cables in walls

    nSet consisting of transmitter and

    receiver in robust carrying case

    nTransmitter signal displayed

    optically and acoustically

    by the receiver

    nTransmitter with integrated

    BS1363 UK plug enabling easy

    connection to mains socket

    nSimple switching between fuse

    and cable finder function

    nContinuous sensitivity

    adjustment of receiver

    ECB50A-ECircuit Breaker Finder

  • 8/19/2019 21128 Robin Shortform Catalogue 2014 v7

    12/28

    Beha-Amprobe are renowned around

    the world for innovative Clamp Meters.

    The selection includes the Swivel Clamp

    Meter and the high performance

    Navigator Clamp.

    Clamp-on Meters

    2

  • 8/19/2019 21128 Robin Shortform Catalogue 2014 v7

    13/28

    ACDC-400Clamp Multimeter 400A

    ACD-20SWSwivel Clamp Meter 400A

    n Current, voltage and

    resistance measurementn Continuity test with beeper

    n Measurement of inrush

    current (30 ms)

    n Automatic and manual

    range selection

    n Integrated measurement

    memory (data hold)

    n  Jaw opening: 50 mm

    n Auto power-off 

    Additional Features

    n Large, clear display

    ACDC-100Clamp Multimeter 1000A

    n Current, voltage and

    resistance measurement

    n Continuity test with beeper

    n Automatic and manual

    range selection

    n Integrated measurement

    memory (data hold, MIN/MAX)

    n Relative measurement

    n Additional bar graph display

    n  Jaw opening: 30 mm

    n Auto power-off 

    Additional Features

    n AC/DC clamps are also suitable

    for automotive applications,

    emergency power supplies

    and solar technology

    n Backlight

    ACD-14 PLUSCurrent clamp with dual

    display up to 600 A (AC)

    nCurrent, voltage and

    resistance measurement

    nContinuity test with beeper

    nCapacitance and frequency

    measurement

    nTemperature measurement

    nMeasurement of inrush current

    nAutomatic range selection

    nIntegrated measurement memory

    (data hold and MAX hold)

    n Jaw opening: 26 mm

    nAuto power-off 

    Additional Features

    nDual display

    nA measurement range for direct

    measurement of ionisation

    currents in heating systems

    nMeasures current, voltage

    and resistance

    nAudible continuity test

    nDiode test

    nAuto and manual ranging

    nMeasured data storage

    (Data Hold)

    nAccomodates conductors

    up to 30 mm in diameter

    nAuto-Power-Off 

    Additional Features

    n180 degree rotating head

    for the perfect display

    nAdvanced VoltTect non-

    contact voltage detection

       C   l  a  m  p -  o

      n   M

      e  t  e  r  s

    13

  • 8/19/2019 21128 Robin Shortform Catalogue 2014 v7

    14/28

    4

    LH41Current Clamp Meter AC/DC

    n Current measurement

    from 1 mA AC and DC

    n Manual range selection

    n  Jaw opening: 19 mm

    n Automatic zero-point (DC

    measurement range)

    n Integrated 5 s measurement

    memory (data hold)

    n Auto power-off 

    Additional Features

    n Minimum resolution: 1 mA

    n Shielded against external

    interference

    n Leakage current measurement

    n Voltage and resistance

    measurement

    n Continuity test with beeper

    n Manual range selection

    n Integrated measurement

    memory (data hold)

    n MIN/MAX and relative

    value measurement

    n Additional bar graph display

    n  Jaw opening: 30 mm

    n Auto power-off 

    Additional Features

    n Minimum resolution: 0.01 mA

    n Range of applications:

    measurement of leakageor fault currents, current

    consumption of devices in

    (customer) service sector

    without breaking the circuit

    AC50ALeakage Clamp Meter

    ACD-50NAV600A AC Navigator Clamp

    n Current, voltage andresistance measurement

    n Measurement of activepower (W)

    n Measurement of thepower factor cos ф

    n Acoustic continuity testn Capacity and frequency

    measurementn Harmonics measurement for

    current and voltage values(up to the 25th harmonic)

    nTHD measurement

    nMeasurement of theinrush currentnDisplay of the rotary

    field directionnAutomatic measuring

    range selectionnTRMS measurement (ACD-

    52NAV, ACD-53NAV,ACD-54NAV only)

    n Integrated measurement

    memory (Data Hold,MIN/MAX)n Additional bargraph displayn Peak value measurementn Low Pass frequency filtern Large clear display with

    background lightn Clamp opening 37 mmn Auto-Power-Off 

    Additional FeaturesnReal effective value measurement AC+DC (TRMS)nContactless voltage detectionnMeasurement point illumination by means of white LED

    ACDC-54NAV1000A AC/DC TRMSNavigator Clamp

    n Current, voltage andresistance measurement

    n Acoustic continuity testn Capacity and frequency measurementn Temperature measurementn Measurement of effective power (W)n

    Measurement of thepower factor cos фn Harmonic measurement for

    current and voltage values(up to the 25th harmonic)

    n Measurement of the inrush currentn Display of the rotary field directionn Automatic measuring range selectionn Integrated measurement memory

    (Data Hold, MIN/MAX)n Additional bargraph displayn Peak value measurementn Low Pass frequency filtern Large clear display with

    background lightn Clamp opening 42 mm

    n Auto-Power-Off 

    Additional FeaturesnReal effective value measurement AC+DC (TRMS)nContactless voltage detectionnMeasurement point illumination by means of white LED

  • 8/19/2019 21128 Robin Shortform Catalogue 2014 v7

    15/28

    15

    Beha-Amprobe offer a wide range of Digital

    Multimeters for the UK electrician at

    affordable prices.

    Digital Multimeters

  • 8/19/2019 21128 Robin Shortform Catalogue 2014 v7

    16/28

    6

    AM-520-EURDMM

    n750V AC/DC

    n 10A AC/DC

    n Capacitance and frequency

    measurement

    n Temperature measurementn Automatic and manual

    range selection

    n Auto power off 

    n Non-contact voltage detection

    n Built-in flashlight

    Contents

    n Model AM-520 EUR

    n Test leads

    n 1 x Temperature probe

    n Carrying case

    n 1 x 9V (6F22) battery (installed)

    n Users manual

    n Hang strap

    AM-530-EURDMM TRMS

    nAC 750V/DC 1000V

    n10A AC/DC

    nTRMS measurement

    nCapacitance and frequency

    measurement

    nTemperature measurement

    nAutomatic and manual

    range selection

    nAuto power off 

    nNon-contact voltage detection

    nBuilt-in flashlight

    Contents

    nModel AM-530 EUR

    nTest leads

    n1 x Temperature probe

    nCarrying case

    n1 x 9V (6F22) battery (installed)

    nUsers manual

    nHang strap

    AM-500-EURCompact Size DMM

    nAutoranging feature

    automatically sets up

      voltage, current, and

    resistance ranges for you

    nVoltage up to 600V AC/DC

    nResistance

    nAudible continuity

    nDiode test

    nData hold

    nAuto power off 

    nLow battery warning

    nSafety rated: CAT III 600V

    Contents

    n Model AM-500 EUR

    n Test leads

    n AAA x 2

    n Users manual

    AM-510-EURDMM

    n 600V AC/DC

    n10A AC/DC

    n Capacitance and frequency

    measurement

    n Temperature measurement

    n Automatic and manual

    range selection

    n Auto power off 

    n Battery test (1,5V and 9V)

    n Non-contact voltage detection

    n Built-in flashlight

    Contents

    n Model AM-510 EUR

    n Test leads

    n 1 x 9V (6F22) battery (installed)

    n Users manual

  • 8/19/2019 21128 Robin Shortform Catalogue 2014 v7

    17/28

  • 8/19/2019 21128 Robin Shortform Catalogue 2014 v7

    18/28

    The Beha-Amprobe series of infrared and

    contact thermometers are a complete

    line of high performance diagnostic tools

    designed for HVAC/R, electrical, industrial

    maintenance applications.

    Temperature Measurement

    18

  • 8/19/2019 21128 Robin Shortform Catalogue 2014 v7

    19/28

       T  e  m  p  e  r  a  t  u  r  e

       M  e  a  s  u  r  e  m  e  n  t

    19

    IR-710-EURInfrared Thermometer (10:1)

    nExtremely accurate and reliable

    nPrecise measurement with

    distance to spot ratio 10:1

    nWide temperatures

    ranges available up to

      -0°F to 716°F

    (-18°C to 380°C )

    nRapid response time

    nLaser pointer for accurate targeting

    n8 seconds auto display

    hold for easy read-out

    nAdjustable emissivity for

    measuring a variety of materials

    nDual LCD display with backlight

    nSelectable ˚F and ˚C

    IR-720-EURInfrared Thermometer (20:1)

    nExtremely accurate and reliable

    nPrecise measurement with

    distance to spotratio 20:1

    nWide temperatures

    ranges available up to

      -26°F to 1922°F

    (-32°C to 1050°C )

    nRapid response time

    nLaser pointer for accurate targeting

    n8 seconds auto display

    hold for easy read-out

    nAdjustable emissivity for

    measuring a variety of materials

    nDual LCD display with backlight

    nSelectable ˚F and ˚C

    IR-750-EURInfrared Thermometer (50:1)

    nExtremely accurate and reliable

    nPrecise measurement with

    distance to spot ratio 50:1

    nWide temperatures

    ranges available up to

      -58°F to 2822°F

    (-50°C to 1550°C )

    nRapid response time

    nLaser pointer for accurate targeting

    n8 seconds auto display

    hold for easy read-out

    nAdjustable emissivity for

    measuring a variety of materials

    nDual LCD display with backlight

    nSelectable ˚F and ˚C

    nStores up to 99 data points

    nThermocouple inputnUSB interface

    IR-730-EURInfrared Thermometer (30:1)

    nExtremely accurate and reliable

    nPrecise measurement with

    distance to spot ratio 30:1

    nWide temperatures

    ranges available up to

      -26°F to 2282°F

    (-32°C to 1250°C )

    nRapid response time

    nLaser pointer for accurate targeting

    n8 seconds auto display

    hold for easy read-out

    nAdjustable emissivity for

    measuring a variety of materials

    nDual LCD display with backlight

    nSelectable ˚F and ˚C

  • 8/19/2019 21128 Robin Shortform Catalogue 2014 v7

    20/28

    20

    TMD-50Thermometer

    TMD-50, Type K

    n Dual (Temperature

    measurement with connection

    for two sensors)n -60 to 1350 °C, -58 to 2498 °F

    n Measurement of the

    temperature difference

    n Connection for two

    temperature sensors type K

    n Switchable for measurement

    in °C or °F

    n Integrated measurement

    memory (Data Hold)

    n MIN/MAX and relative

    value measurement

    n Measurement of the

    average temperature

    nBacklit display

    n Auto-Power-Off 

    Additional Features

    n Best precision 0.1%

    n T1-T2 (temperature

    difference)

    n Shock and impact-

    resistant by standard

    protective cover

    IR608AInfrared Thermometer

    Laser Pointer

    n Non-contact temperature

    measurement

    n Switchable between °C

    and °F measurement

    n Integrated measurement

    memory (data hold)

    n Backlight

    n Distance to spot size ratio: 8:1

    n Auto power-off 

    Additional Features

    n Laser-based targeting

    n Handy and compact

    “pistol grip” design

    IR-450-EURPocket Infrared Thermometer

    nIR pocket thermometer with

    8:1 distance to spot ratio

    nSelectable °F / °C

    nHolds temperature

    reading for 10 seconds

    nBright laser pointer

    nBuilt-in LED flashlight to

    illuminate dark areas

    TH-3Relative Humidity

    Temperature Meter

    n Dual display

    nRelative function monitors

      humidity and temperature

      changes

    nExtended probe stem to easily

      access air ducts

    nMin/Max readings 

    Data Hold

    nCapacitive sensor with

      protective cover

    nAuto Power off 

    nSoft Carrying Case

    nOne-year warranty

  • 8/19/2019 21128 Robin Shortform Catalogue 2014 v7

    21/28

    Need something a little different? Always

    check the Beha-Amprobe range. This section

    has a selection of other Beha-Amprobe

    test equipment for electrical and HVAC

    applications.

    Other Test Equipment

    21

  • 8/19/2019 21128 Robin Shortform Catalogue 2014 v7

    22/28

    22

    TMA10Anemometer ThermometerAnemometer with remote vane

    n Measure CFM by inputting

    the vent dimensions

    n Obtain air flow average by

    taking up to eight data points

    n Vane has three foot cord for

    measurement flexibilityn Deluxe carrying case

    n Measure air velocity or air flow

    n RS232 interface output

    with optional software

    and cable, TM-SWA

    n Continuous moving average

    for up to 2 hours

    LM-100Light Meter Manual Ranging

    n Light measurement

    n 0-200,000 lux

    n Manual range selection

    n Silicon sensor

    n Integrated measurement

    memory (data hold, MAX)

    LAN-1Lan Cable Tester

    nTest pin configuration for:

      10/100 base -T cable

      10 base-2 cable

      RJ45 modular cables

      AT&T 258A cable

      EIA/TIA 568A/568B cables

      Token Ring Cable

    nVerify the cable wiring for

    continuity, opens, shorts or

    incorrect wiring

    nTest installed cable on wallplate or the patch panels by

    using the Remote

    Termination module

    nPerform Loopback Test

    or Remote Test

    nBuzzer sound warning for

    error condition in cable

    nTwo sets of LED lights for

    Source and Test indication

    LM-120Light Meter withAuto Ranging

    nMeasure in Lux or Footcandles,

    front panel switchable

    nMeasuring Range to 200,000

    Lux or 20,000 Foot candlesnSilicon photodiode

    sensor and filter

    nData Hold to freeze reading

    on the digital display

    nMIN / MAX ability to show

    high and low readings

    nAutoranging plus Manual Range

    nZero function to null

    display before a reading

    nAuto Power Off to

    PRM4

    Phase Sequence and MotorRotation Tester

    n Identifies 3-phase sequence

    and open phase check 

    n Motor shaft rotation indication

    protected by CAT III circuitry

    n CAT III 600V rated for

    both testing segments

    n Meets current EN61010 safety

    requirements, CSA, EN61557-7

    n Supplied with three CAT IIIrated color coded large

    alligator clips and test leads

    n Zippered carrying case

    for portability

  • 8/19/2019 21128 Robin Shortform Catalogue 2014 v7

    23/28

       O

      t   h  e  r  s

    23

    SM-10Sound Meter

    nMeasurement of sound leveln30-130 dB

    nMeasurement according to

    frequency evaluation filters A

    and C, with direct display in dB

    nIntegrated measurement

    memory (data hold, MAX)

    nSwitchable between fast

    and slow response times

    nBacklight

    TACH20Combo Tachometer

    nMeasures rotational

    and surface speed

    nBuilt-in memory

    nDigital Display

    nAuto power off function

    nEasy to select units

    and mode functions

    nContact and non-

    contact measurement

    nSelect rpm using infrared

    beam or adapter: m/min, m/sec,  ft/min, ft/sec, in/min, m, ft, and in.

    nIncludes 6 Adapters, Carrying

    Case, Reflective Tapes,

      Batteries and User Manual

    PQ55ACompact Power Analyser

    n Comprehensive real time

    monitoring, recording and

      analysis of three phase

    power systems

    n True-rms voltage and

    current measurementn Power Factor and

    phase angle results

    n Power Analysis (apparent,

    active and reactive power)

    TX900Microwave Leakage

    Detector

    n Measures for wave leakage

    and tests oven power

    n 8 dipole sensors – allows

    detection of plane wave signals

      of any polarization

    n Temperature compensation

     – accurate reading regardless

      of ambient temperature changesn Compact, ergonomic design

    n Low battery indication

    n Analog Bar Graph

    n Auto-zero

    LT-10-EURLamp Tester

    nDetermine if fluorescent light

    bulbs are operational prior

    to installation or removal

    nVerify voltage presence without

    the need for another tool with

    built-in VolTect™ non-contact

    voltage detection

    nIncrease productivity

    by minimising trips up

    and down a ladder

    nAll tests performed with easy,

    single button operation

    nUltra-compact design

    for portability

    nIndustry leading 120cm

    (48”) removable, fully

    retractable antenna

    nInsulated antenna sleeve

    for safe testing

  • 8/19/2019 21128 Robin Shortform Catalogue 2014 v7

    24/28

    24

    Specifications (At 23°C ± 5°C, 45% to 75% RH)

    Insulation Resistance @250V/500/1000V (TestCurrent ≥ 1mA)

    0.00MΩ ~ 250MΩ@ 250V0.00MΩ ~ 500MΩ@ 500V0.00MΩ~1000MΩ@ 1000V

    (Buzzer threshold: 2MΩ)

    ±(5% rdg + 5 LSD)

    Continuity @ IN ≥ 200mA,Uo=5Vdc (Nominal)

    0.00Ω ~ 199Ω(Buzzer threshold: 20Ω)

    ±(2% rdg + 5 LSD)

    AC Voltage Measurement 0Vac ~ 400Vac ±(5% rdg + 2 LSD)@ 45 to 65Hz

    Operating Voltage(Loop and RCD)

    230Vac, 45Hz ~ 65 Hz +10% to -15%

    Line Impedance (L – N) @ 25A 0.01Ω ~ 1.99Ω / 2.0Ω ~19.9Ω / 20Ω ~ 2000Ω

    ±(5% rdg + 5 LSD)

    Loop Impedance

    (L – PE) @ 25A

    0.01Ω ~ 1.99Ω / 2.0Ω ~

    19.9Ω / 20Ω ~ 2000Ω

    ±(5% rdg + 5 LSD)

    Loop impedance withouttripping @ 15mA

    0.01Ω ~ 1.99Ω / 2.0Ω ~19.9Ω / 20Ω ~ 2000Ω

    ± (5% rdg + 12 LSD+ Noise Margin

    (0.01 - 1.99Ω))

    Prospective Short CircuitCurrent (PSC) @ 25A

    Prospective Earth Fault

    Current (PSC) @ 25A

    0.00A ~ 1.99A / 2.0A~ 19.9A / 20A ~ 199A

    / 200A ~ 1.99kA

    / 2.0kA ~ 26kA

    PSC accuracy derivedfrom measured loop

    impedance specification

    and measuredvoltage specification

    RCD Test Current 10/30/100/300/500mA 0% to 10% @1∆n and 5∆n≤-10% to 0% @ ½∆n

    RCD Trip Times @ X½ 0 ~ 2000ms(10/30/100/300/500mA)

    ±(1% rdg + 2 ms)

    RCD Trip Times @ X1 0 ~ 500ms (selective)(10 / 30 / 100 /300 / 500mA)

    ±(1% rdg + 2 ms)

    RCD Trip Times @ X1 0 ~ 300ms (10 / 30/ 100 / 300mA)

    ±(1% rdg + 2 ms)

    RCD Trip Times @ X5 0 ~ 40ms (10 /

    30 / 100mA)±(1% rdg + 2 ms)

    RCD Auto Test X½ / X1 / X5 (10

    / 30 / 100mA)Trip time: ±(1% rdg +

    2 ms) Trip current: 0%to 10% @ 1∆n and 5∆n-10% to 0% @ ½∆n

    RCD RAMP Test X½ / X1 / X5 (10 / 30/ 100 / 300 / 500mA)

    50% ~ 110% Defaultnominal residual

    currents (I∆n).Increasing by10%, total 7

    steps of residual current

    Fault Voltage Detection(N – PE conductor)

    50Vac or more

    Operating Temperature 0°C to +40°C, ≤ 85% RH, no condensation

    Storage Temperature -20°C to +60°C, ≤ 90% RH, nocondensation (without batteries)

    Power Supply 1.5V Alkaline Battery (AA Battery) × 8 pcs

    Dimensions (L x W x H) 189 x 168 x 85 mm (7.43 x 6.65 x 3.35 in)

    Product Weight Approx. 1.3 kg (2.87 lb) with batteries installed

    Regulat ion Compliance Designed to a llow test ing to BS7671IEE 17th Edition regulations

    BS EN 61010-1 CAT III 300VBS EN 61557-1 / -2 / -3 / -4 / -6 / -10

    BS EN 61326-1 (EMC)

    Included Accessories 3-Wires mains test cord set , test lead (red,black green), test probe (red, black, green),alligator clips (red, black, green), Test probewith Remote Test Button, users manual,strap and carrying case

    KTS1625

    Specifications (At 23°C ± 5°C, 45% to 75% RH)

    Operating Voltage 230Vac, 45Hz ~ 65 Hz +10% to -15%

    Earth Loop Impedance 20Ω 0.01Ω ~ 19.99Ω@ Nominal Test

    Current 25A

    ±(3% rdg + 4 LSD)

    Earth Loop Impedance 200Ω 20.0Ω ~ 199.9Ω@ Nominal Test

    Current 2.3A

    ±(3% rdg + 4 LSD)

    Earth Loop Impedance 2000Ω 200Ω ~ 1999Ω@ Nominal Test

    Current 15mA

    ±(3% rdg + 4 LSD)

    Non tripping Loop test 20Ω 0.01Ω ~ 19.99Ω ±(3% rdg + 6 LSD)

    Non tripping Loop test 200Ω 20.0Ω ~ 199.9Ω ±(3% rdg + 7 LSD)

    Prospective Short Circuit

    Current (PSC)200A / 2000A / 20kA

    0.0 ~ 199.9 /

    1999 / 19.9kA

    PSC accuracy derived

    from measured loop

    impedance specificationand measured

    voltage specificationRCD Test Current 10/30/100/300/500mA 0% to 10% @

    1∆n and 5∆n≤-10% to 0% @ ½∆n

    RCD Trip Times @ X½ 0 ~ 2000ms(10/30/100/300/500mA)

    ±(1% rdg + 2 ms)

    RCD Trip Times @ X1 0 ~ 1000ms (selective)(10/30/100/300/500mA)

    ±(1% rdg + 2 ms)

    RCD Trip Times @ X1 0 ~ 1000ms

    (10/30/100/300mA)±(1% rdg + 2 ms)

    RCD Trip Times @ X5 0 ~ 40ms

    (10/30/100mA)±(1% rdg + 2 ms)

    RCD Auto Test X½ / X1 / X5 (10/ 30 / 100mA)

    Trip time: ±(1%rdg + 2 ms)Trip current: 0% to10% @ 1∆n and 5∆n

    -10% to 0% @ ½∆nRCD RAMP Test X½ / X1 / X5 (10 / 30

    / 100 / 300 / 500mA)50% ~ 110% Defaultnominal residual

    currents (I∆n).Increasing by 10%,total 7 steps of

    residual current

    Fault Voltage Detection(N – PE conductor)

    Selectable 25V or 50Vac

    Voltage Measurement 0Vac ~ 600Vac ± (2% rdg + 3 LSD)@ 45Hz ~ 65 Hz

    Operating Temperature 0°C to +40°C, ≤ 85% RH, no condensation

    Storage Temperature -20°C to +60°C, ≤ 90% RH, nocondensation (without batteries)

    Power Supply 1.5V Alkaline Battery (AA Battery) × 8 pcs

    Dimensions (L x W x H) 189 x 168 x 85 mm (7.43 x 6.65 x 3.35 in)

    Product Weight Approx. 450g (0.99 lb)

    Regulation Compliance Designed to a llow test ing to BS7671IEE 17th Edition regulations

    BS EN 61010-1 CAT III 300V

    BS EN 61557-1 / -3 / -6 / -10BS EN 61326-1 (EMC)

    Included Accessories 3-wires mains test cord with UK plug , test leads(red, black green), test probes (red, black,green), alligator clips (red, black, green),users manual, strap and carrying case

    KMP7100

    Multi-Function Installation Testers

    Technical Specification

  • 8/19/2019 21128 Robin Shortform Catalogue 2014 v7

    25/28

       T  e  c

       h  n

       i  c  a   l

        S  p  e  c   i   f

       i  c  a  t

       i  o  n

    25

    Specifications (At 23°C ± 5°C, 45% to 75% RH)

    Earth Resistance Measurement 0.00Ω ~ 40.00Ω0.0Ω ~ 400.0Ω0Ω ~ 4000Ω

    ± (2% rdg + 20 LSD)± (2% rdg + 3 LSD)± (2% rdg + 3 LSD)

    Voltage Measurement 0Vac ~ 400Vac ± (1% rdg + 6 LSD)@ 50 / 60 Hz

    Operating Temperature +5°C to +40°C, ≤80% RH, no condensation

    Storage Temperature -20°C to +60°C, ≤90% RH, nocondensation (without batteries)

    Power Supply 1.5V Alkaline Battery (AA Battery) × 6 pcs

    Dimensions (L x W x H) 160 x 101 x 71 mm (6.3 x 3.98 x 2.79 in)

    Product Weight Approx. 500g (1.1 lb) with batteries installed

    Regulation Compl iance Designed to al low testing to BS7671

    IEE 17th Edition regulationsBS EN 61010-1 CAT III 400V

    BS EN 61557-1, BS EN 61557-5

    BS EN 61326-1 (EMC)

    Included Accessories Three Test Leads (Green, Yellow and Red),Auxiliary ground rods, Two test leads withalligator clips, Batteries ( 6 x AA), UsersManual, Strap and Carrying case

    Specifications (At 23°C ± 5°C, 45% to 75% RH)

    Insulation Resistance @

    250V/500/1000V (TestCurrent ≥1mA)

    0.00MΩ ~ 4.99MΩ5.0MΩ ~ 49.9MΩ50MΩ ~ 999MΩ1.00GΩ ~ 1.99GΩ(Buzzer threshold: 4MΩ)

    ± (3% rdg + 5 LSD) for0.00MΩ ~ 99.9MΩ± (5% rdg + 5 LSD) for 100MΩ ~ 1.99GΩ

    Continuity @ IN ≥200mA,Uo=5Vdc (Nominal)

    0.00MΩ ~ 9.99 MΩ10.0MΩ ~ 99.9 MΩ

    ± (2% rdg + 5 LSD)

    AC Voltage Measurement 30Vac ~ 750Vac ± (2% rdg + 3 LSD)@ 50 / 60Hz

    Operating Temperature 0°C to +35°C, ≤75% RH, no condensation

    Storage Temperature -20°C to +60°C, ≤80% RH, nocondensation (without batteries)

    Power Supply 1.5V Alkaline Battery (AA Battery) × 6 pcs

    Dimensions (L x W x H) 160 x 101 x 71 mm (6.3 x 3.98 x 2.79 in)

    Product Weight Approx. 450g (0.99 lb) with batteries installed

    Regulat ion Compliance Designed to a llow test ing to BS7671IEE 17th Edition regulations

    BS EN 61010-1 CAT III 600V

    BS EN 61557-1 / -2 / -4 / -10BS EN 61326-1 (EMC)

    Included Accessories Test Leads (red, black), probes (red, black),alligator clips (red, black), Battery, InstructionManual, Carrying case, Strap

    KMP7010 KMP7036

    Specifications (At 23°C ± 5°C, 45% to 75% RH)

    Operating Voltage 230Vac, 45Hz ~ 65 Hz +10% to -15%

    Loop Impedance 20

    / 200 / 2000Ω0 ~ 19.99 / 199.9

    / 1999 Ω±(3% rdg + 4 LSD)

    AC Test Current 25A Nominal at 20Ω

    AC Test Period 10ms at 20Ω

    No Trip Loop Impedance20 / 200Ω

    0 ~ 19.99 / 199.9 Ω (L – N impedance > 20 Ω)

    ± (3% rdg + 6 LSD)

    PSC Measurement 200A/ 2000A / 20kA

    0.0 ~ 199.9 /1999 / 19.9kA

    PSC accuracy derivedfrom measured loop

    impedance specification

    and measuredvoltage specification

    Voltage Measurement 100Vac ~ 300Vac ± (2% rdg + 4 LSD)@ 50/60Hz

    Operating Temperature 0°C to +40°C, ≤ 85% RH, no condensation

    Storage Temperature -20°C to +60°C, ≤ 90% RH, nocondensation (without batteries)

    Power Supply 1.5V Alkaline Battery (AA Battery) × 8 pcs

    Dimensions (L x W x H) 189 x 168 x 85 mm (7.43 x 6.65 x 3.35 in)

    Product Weight Approx. 450g (0.99 lb)

    Regulat ion Compliance Designed to a llow test ing to BS7671

    IEE 17th Edition regulationsBS EN 61010-1 CAT III 300V

    BS EN 61557-1, BS EN 61557-3BS EN 61326-1 (EMC)

    Included Accessories Mains Test cord with Earth Probe,

    Batteries (8 x AA), User’s Manual,Strap and Carrying Case

    Specifications (At 23°C ± 5°C, 45% to 75% RH)

    Operating Voltage 230Vac, 50 Hz +10% to -15%

    Trip current @ X½ 10/20/30/100/300/500mA

    (trip time 0 to 2000ms)Trip current tolerance:

    -10% to +10%Trip Time: ± (2%

    rdg + 2 LSD)

    Trip current @ X1 10/20/30/100/300mA(trip time 0 to 1000ms)500mA (trip time0 to 300ms)

    Trip current tolerance:0% to +10%

    Trip Time: ± (2%rdg + 2 LSD)

    Trip current @ X5 10/20/30mA (trip

    time 0 to 40ms)Trip current tolerance:

    0% to +10%Trip Time: ± (2%

    rdg + 2 LSD)

    Fast Trip Current (KMP7020) 250mA (trip time0 to 40ms)

    Trip current tolerance:0% to +10%

    Trip Time: ± (2%

    rdg + 2 LSD)Ramp Test (KMP7021) 10/20/30/100/300/500mA -10% to +10%

    Ramp increase by 10%Default nominal residual currents

    from 20% to 110%

    Maximum measuring time 300ms x 10 times

    Operating Temperature 0°C to +40°C, ≤80% RH, no condensation

    Storage Temperature -20°C to +60°C, ≤90% RH, no condensation

    Power Supply AC mains 230V +10% -15%, 50 Hz

    Dimensions (L x W x H) 160 x 101 x 71 mm (6.3 x 3.98 x 2.79 in)

    Product Weight Approx. 450g (0.99 lb)

    Regulation Compl iance Designed to al low testing to BS7671

    IEE 17th Edition regulations

    BS EN 61010-1 CAT III 300VBS EN 61557-1, BS EN 61557-6

    BS EN 61326-1 (EMC)

    Inc luded Accessories 3-Wires Mains Test Cord, Test Lead Set,Users Manual, Strap and Carrying case

    KMP7020/KMP7021 KMP7030

    Single-Function Installation Testers

  • 8/19/2019 21128 Robin Shortform Catalogue 2014 v7

    26/28

    Technical Specification

    26

    Clamp-on Meters

    Clamp Multimeter Comparison GuideACD-14 Plus ACDC-400 ACD-20SW ACDC-100 ACD-50NAV

    Display

    LCD, 33/4-digit,

    4000 digits

    LCD, 3¾ Digit,

    3999 Count

    LCD, 3¾ Digit,

    3999 Count

    LCD, 3¾ Digit,

    4000 Count

    LCD, 3¾ Digit,

    4000 Count

       M  e  a  s  u  r  e  m  e  n  t

       R  a  n  g  e  s

    Current AC 0.01 - 600 A 0.01 A - 400 A 0.01 - 400 A 0.1 A - 800 A 0.01 - 600 A

    Tolerance ±(1.9% rdg. + 8 digits) ±(1.5% rdg. +3 Digits) ±(2% rdg +6 Digits) ±(1.5% rdg. +5 Digits) ±(1.5 % rdg. +5 Digits)

    Frequency Range 50/60 Hz 50/60 Hz 50-60 Hz 50 Hz - 400 Hz

    Current DC - 0.01 A - 400 A - 0.1 A - 1000 A -

    Tolerance - ±(1.5% rdg. +3 Digits) - ±(1.5% rdg. +4 Digits) -

    Voltage AC 0.001 - 600 V 0.1 mV - 600 V 1.0 mV-600,0 V 0.1 mV - 600 V 0.01 - 1000 V

    Tolerance ±(1.5% rdg. + 5 digits) ±(1% rdg. +3 Digits) ± (1.2% rdg +5 Digits) ±(1% rdg. +4 Digits) ±(1 % rdg. +5 Digits)

    Frequency Range 50 - 400 Hz 50 - 500 Hz 50 - 500 Hz 50 - 500 Hz 50 Hz - 500 Hz

    Voltage DC 0.1 - 600 V 0.1 mV - 600 V 0.1 mV - 600 V 0.1 mV - 600 V 0.01 - 1000 V

    Tolerance ±(0.5% rdg. + 3 digits) ±(0.8% rdg. +2 Digits) ±(0.5% rdg +2 Digits) ±(0.5% rdg. +3 Digits) ±(0.7 % rdg. +2 Digits)

    Continuity R < 120 Ω R < 40 Ω R < 25 Ω R < 120 Ω R < 30 Ω

    Frequency 0.001 Hz - 100 kHz - - - 20,00 - 9,999 kHz

    Resistance 0.1 - 40.00 MΩ 0.1 Ω - 40 MΩ 0.1 Ω - 40 MΩ 0.1 Ω - 40.00 MΩ 0.1–99.99 kΩ

    Tolerance ±(0.8% rdg. + 6 digits) ±(1% rdg. +3 Digits) ±(1.0% rdg +4 Digits) ±(0.8% rdg. +6 Digits) -

    Capacity 0.1 nF - 3000 µF - - - -

    Active Power - - - - 0 - 600.0 kW

    Cos Phi - - - - -1.00–0.00 – +1.00

    Harmonics - - - - display up to the 25th

       F  e  a  t  u  r  e  s

     Jaw Opening Ø 26 mm Ø 30 mm Ø 30 mm Ø 50 mm Ø 37 mm

    Pollution Degree 2 2 2 2 2

    Overvoltage Category CAT III/600 V CAT III/600 V CAT lll/600 V CAT III/600 VCAT IV 600V,CAT III 1000V

    Safety EN 61010/IEC 61010DIN VDE 0411,

    EN 61010, IEC 61010DIN VDE 0411,

    EN 61010/IEC 61010DIN VDE 0411,

    EN 61010, IEC 61010DIN VDE 0411,

    EN 61010, IEC 61010

    Power Supply2 x 3 V battery,IEC CR2032

    2 x Battery 1.5 V,IEC LR03

    2 x Batterie 1.5 V,IEC LR03

    2 x Battery 1.5 V,IEC LR03

    1 x Battery 9 V,IEC 6F22

    Dimensions 190 x 63 x 32 mm 205 x 64 x 39 mm 240 × 70 × 41 mm 227 x 78 x 40 mm 260 x 80 x 40 mm

    Weight approx. 200 g approx. 280 g approx. 220 g approx. 290 g approx. 480 g

    Clamp Multimeter Comparison GuideACDC-54NAV LH41 AC50A

    DisplayLCD, 3¾ Digit,

    4000 Count

    LCD, 3¾ Digit,

    4000 Count

    LCD, 3¾ Digit ,

    3999 Count

       M  e  a  s  u  r  e  m  e  n  t

       R  a  n  g  e  s

    Current AC 0.01-1000 A 0.001 - 40 A 0.01 mA - 60 A

    Tolerance ±(1.5 % rdg. +5 Digits) ±(1.3 % rdg. +5 Digits) ±(1.5% rdg. +5 Digits)

    Frequency Range 50 Hz - 400 Hz 40 - 400 Hz 40 Hz - 1 kHz

    Current DC - 0,001 - 40 A -

    Tolerance - ±(1.3 % rdg. +5 Digits) -

    Voltage AC 0,01 - 1000 V - 0,1 - 400 V

    Tolerance ±(1 % rdg. +5 Digits) - ±(2% rdg. + 4 Digits)

    Frequency Range 50 - 500 Hz - 40 Hz - 1 kHz

    Voltage DC 0.01 - 1000 V - -

    Tolerance ±(0.7% rdg. +2 Digits) - -

    Continuity R < 30 Ω - R < 40 Ω

    Frequency 20.00 - 9.999 kHz - -

    Resistance 0.1–99.99 kΩ - 0.1 - 400 Ω

    Tolerance ±(1% rdg. +5 Digits) - ±(1% rdg. +2 Digits)

    Capacity - - -

    Active Power 0 - 999.9 kW - -

    Cos Phi -1.00–0.00 – +1.00 - -

    Harmonics display up to the 25th - -

    Temperature -50 °C-1000 °C - -

    Input Impedance - - 10 MΩ

       F  e  a  t  u  r  e  s

     Jaw Opening Ø 37 mm Ø 19 mm Ø 30 mm

    Pollution Degree 2 2 2

    Overvoltage Category

    CAT IV 600V,

    CAT III 1000V CAT III/600 V CAT III/600 V

    SafetyDIN VDE 0411,

    EN 61010/IEC 61010

    DIN VDE 0411,

    EN 61010, IEC 61010

    DIN VDE 0411

    EN 61010, IEC 61010

    Power Supply1 x battery 9 V,

    IEC 6F22

    1 x Battery 9 V, IEC 6LR61

    2 x Battery 1.5 V,IEC LR6

    Dimensions 260 x 80 x 40 mm 184 x 71 x 31 mm 210 x 62 x 36 mm

    Weight approx. 480 g approx. 235 g approx. 200g

  • 8/19/2019 21128 Robin Shortform Catalogue 2014 v7

    27/28

       T  e  c

       h  n

       i  c  a   l

        S  p  e  c   i   f

       i  c  a  t

       i  o  n

    27

    Portable Appliance Testers

    Specifications GT-400-UK  Protective conductor resistance   0.10 ... 2.00 Ω ± (5% + 10 digits)  Insulation resistance 0.100 ... 9.999 MΩ, 10.00 ... 20.00 MΩ ± (5% + 2 Digits)  Substitute leakage current 0.100 ... 9.999 mA, 10.00 ... 20.00 mA ± (5% + 2 Digits)

      Supplied with  Test leads, alligator clip, test probe, IEC lead, carrying

    case, 6 AA batteries, users manual

     Protective Conductor Resistance  Measuring range   0.10 ... 2.00 Ω  Display range   0.05 ... 2.00 Ω  Resolution   0.01 Ω  Tolerance   ± (5% + 10 digits)  Measuring current / voltage Min. ± 200 mA DC / > 4 V

    Insulation Resistance  Measuring range   0.1 ... 20 MΩ  Display range   0.1 ... 20 MΩ  Resolution 0.1 ... 9.999 MΩ 0.001 MΩ / 10.00 ... 20.00 MΩ 0.01 MΩ  Tolerance   ± (5% + 2 digits)  Measuring current / voltage Min . 500 V DC / >1 mA

    Substitute Leakage Current  Measuring range 0.1 ... 20 mA  Display range 0.1 ... 20 mA  Resolution 0.1 ... 9.999 mA 0.001 mA / 10.0 ... 20.00 mA 0.01 mA  Tolerance   ± (5% + 2 digits)  Measuring current / voltage   Approximately 32 V AC

    General Specifications

      Power supply  6 x 1.5 V Batteries (IEC LR6 (AA)  6 x 1.2 V NiMH rechargeable batteries

      Degree of pollution 2  Overvoltage category CAT II 300 V

    Protection degree IP40  Protection class II  Electrical safety EN61010-1/VDE0411  EMC emission EN61000-6-3  EMC interference resistance EN61326-1  Dimensions (L x W x H)  Approximately 265 x 110 x 50 mm  Weight Approximately 700 g 

    GT-400-UK

    Digital Multimeters

    Series Selection Guide AM-500-EUR AM-510-EUR AM-520-EUR AM-530-EUR AM-540-EUR AM-550-EUR

    MULTIMETER TYPE Autoranging Com / Res HVAC Electrical Adv. HVAC Industrial

       F  u  n  c  t   i  o  n  s

    Safety Rating Safety CAT III 600V CAT III 600V CAT III 600VCAT II 1000 CAT III 600VCAT II 1000 CAT IV 600CAT III 1000 CAT IV 600CAT III 1000

    Measure voltage in noisy environments True-rms n n

    Electrical panels, AC outlets AC Voltage (V) 600 600 750 750 1000 1000

    DC systems, auto/marine batteries DC Voltage (V) 600 600 1000 1000 1000 1000

    AC Current - electrical panels, appliances AC Current (A) 10 10 10 10 10 10

    DC Current - electronics, DC motors DC Current (A) 10 10 10 10 10 10

    Specified resistance and continuity Resistance (MOhms) 20 40 40 40 60 60

    Flame sensors Microamps n n n n n n

    Diodes in AC to DC converters Diode Test n n n n n n

    Fuses, li ghtbulbs, wire connect ions Continui ty n n n n n n

    Household batteries Battery test n n

    Motor startup or run capacitors Capacitance n n n n n

    Frequency verification Frequency n n n n n

    Non-contact voltage test Non-contact voltage n n n n n

    Electrical load-time on vs time off Duty cyc le n n n

    Temp of air vents, fuses, transformers Temperature inputs 1 1 2 2

       F  e  a  t  u  r  e  s

    Automatically selects measurement range Autoranging n n n n n n

    Manually select measurement range Manual ranging n n n n n

    Voltage on variable frequency drives Low pass fi lter n n

    Detect stray voltages Low Z n

    Dimly lit areas Built-in flashlight n n n n n

       D   i  s  p

       l  a  y

    Meter resolution LCD Counts 2,000 4,000 4,000 4,000 6,000 6,000

    Dimly lit areas Backlight n n n n n

    Monitoring fast changing signals Bar graph n n n n

    Two relative measurements on one screen Dual display n n

       E  v  e  n  t  s

    Data memory Data hold n n n n n n

    Difference between two measurements Relative reading n n n n n

    Max/min peak measurement Max/min hold n n n n

    Specialised signal measurements Peak hold (crest) n n

    Subject to change

  • 8/19/2019 21128 Robin Shortform Catalogue 2014 v7

    28/28

    Robin-Amprobe ® Test Tools UK

    52 Hurricane Way, Norwich, Norfolk, NR6 6JB, United KingdomWeb: www.robin-amprobe.co.uk / www.beha-amprobe.com