Complete System Setup4
System Setup information: http://support.netapp.com/NOW/public/system_setup/
Controller and conguration examples; Universal SAS and ACP Cabling Guide: https://library.netapp.com/ecm/ecm_download_le/ECMM1280392
OnCommand System Manager documentation set: http://support.netapp.com/documentation/productlibrary/index.html?productID=61372
Data ONTAP 8 library: http://support.netapp.com/documentation/productlibrary/index.html?productID=30092
Licenses: http://support.netapp.com/eservice/agree.do?moduleName=PROTOCOL
HELPFUL LINKSVisit the NetApp web site for more information.
Net
Ap
p
sup
po
rt s
ite
Complete conguration5
Create an account. Register your system. Get your license keys.
Register at support.netapp.com1
Provision more storage. Congure other protocols, data protection, and AutoSupport. Set up Service Processor and Remote Support Agent.
Download OnCommand System Manager From http://support.netapp.com/NOW/cgi-bin/software/
3
Download and run Cong AdvisorFrom http://support.netapp.com/NOW/download/tools/cong_advisor/
2
41 2 3 5
51 2 3 4
All four power supplies MUST be powered on.
CAUTION
31
42
CAUTION
31
42
CAUTION
31
42
CAUTION
31
42
Disconnect allsupply power forcomplete isolation.
Disconnect allsupply power forcomplete isolation.
Disconnectallsupplypowerforcompleteisolation.
Disconnectallsupplypowerforcompleteisolation.
CAUTION
31
42
Disconnect allsupply power forcomplete isolation.
CAUTION
31
42
Disconnectallsupplypowerforcompleteisolation.
CAUTION
31
42
Disconnectallsupplypowerforcompleteisolation.
CAUTION
31
42
Disconnect allsupply power forcomplete isolation.
CAUTION
31
42
Disconnect allsupply power forcomplete isolation.
e0a
e0b
LNK LNK LNK LNK
e0a
e0b
LNK LNK LNK LNK
2 4 6 8
1 3 5 7
10 12 14 16
9 11 13 15
12
11
14
13
16
15
6
5
8
7
10
9
2
1
4
31000/100/10MLNK /
1000/100/10MLNK /
MANAGEMENT SUBNET
WINDOWS CLIENT
Subnet
FAS2554 SYSTEM
e0a
e0b
LNK LNK LNK LNK
e0a
e0b
LNK LNK LNK LNK
Power on all external storage ONLY 3
Install System Setup* software on the Windows client
4
Cable Windows client to the same network as your controllers2
Complete conguration worksheet Available in the box or at http://support.netapp.com/NOW/public/system_setup/
1
*If you cannot use System Setup, see the Data ONTAP Software Setup Guide
the system.
When directed, power on your system (or repower).
Wait for discover to complete. Up to 8 minutes.
Enter the values from the conguration worksheet into System Setup.*
Start System Setup software5
Installation and Setup InstructionsFAS2554 Systems
Microsoft Windows clientRuns the software to congure
your storage system
ScrewdriverAdditional network cables
For connecting your storage to your network switch and Microsoft Windows client
Rack space - 4U
Download:
You provide:
System Setup Software: http://support.netapp.com/NOW/public/system_setup/ OnCommand System Manager: http://support.netapp.com/NOW/cgi-bin/software/
Prepare for installation1 4 51 2 3
Power cablesConguration
worksheet Serial cable not needed for this conguration
Starter network, storage, and 10 GbE cables
In the box:
http://support.netapp.com/NOW/public/system_setup/http://support.netapp.com/NOW/cgi-bin/software/
-
Single controller model Double controller model
Double controller modelSingle controller model
Single controller model
Cabling FAS2554 systemswith NO external storage
Cabling FAS2554systems WITH external storageDS424x disk shelves
Cabling FAS2554 systems WITH external storageDS2246 disk shelves
STOP HERE. If you have NO external storage, skip to .
No additional cabling required for a single controller.
Cable storage (Choose option A, B, or C below) 3
A
B
C
For additional congurations, see HELPFUL LINKS.
Ethernet cables
2
1
3
4
Daisy chain SAS ports
Connect rst SAS ports
Connect last SAS ports
Connect ACP ports on controllers to the disk shelves
Storage cables
1 2 3
Ethernet cables
2
1
3
4
Daisy chain SAS ports
Connect rst SAS ports
Connect last SAS ports
Connect ACP ports on controllers to the disk shelves
Storage cables
1 2 3
Connect SAS ports
Ethernet cables
Connect ACP ports
2
Storage cables
4 51 2 3
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
All four power cords MUST be used for all units.
Install hardware2
Rack the system. Rail kit: follow instructions in the rail kit. OR System cabinet: install in the system cabinet.
Place the bezel over the front of the system.
Install system1
2
DO NOT power on system at this point.
3 Connect four power cords
Power cords
LIFTING HAZARDCAUTION
110 lbs (49.9 kg)
To reduce the weight of the disk shelf, remove the power supplies and controllers before lifting.
Use retaining clips
Use retaining clips
Cable controller for 7-Mode Data ONTAP (option A), switched clustered Data ONTAP (option B) or for switchless clustered Data ONTAP (option C)
See your network administrator for help connecting to your switch.
e0a
e0b
LNK LNK LNK LNK
e0a
e0b
LNK LNK LNK LNK
If you are converting from a switchless to a switched conguration, see the appropriate migration manual in the Cluster Management and Interconnect Switches library on the NetApp Support Site.
4 51 2 3
Shelf ID display
Attention LEDPower LED
Bezel
FRONT VIEWOF SYSTEM
BACK VIEWOF SYSTEM
PCM Attention LED
SAS ports (2) e0c-e0f 10 GbE Ethernet ports or 0c-0f Fibre Channel ports(SFP dependent)
One or two controller modulesPower supply
LEDs
Console port (Setting: 9600 N-8-1)
Remote/Node Management port(wrench icon)
ACP port(locked wrench icon)
Gigabit Ethernet ports (2)
NVMEM LED
Attach cable management arms.
Connect port e0c to the data switch.NOTE: Port e0c is required; other ports are available if needed.
Connect the wrench port to the management or subnet switch.
For option B onlyConnect port e0e | 0e and port e0f | 0f to the cluster switch.
For option C onlyConnect port e0e | 0e to port e0e | 0e and e0f | 0f to e0f | 0f.
Strap the cables to the cablemanagement arms.
5
1
2
Network cables3
B4 10 GbE cables
10 GbE cables
C4 10 GbE cables
Switchless clustered Data ONTAP
C
N
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
N
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
1
52
TO MANAGEMENTNETWORK SWITCH
TO DATA NETWORK SWITCH
34
Switched clustered Data ONTAP
B
N
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
N
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
1
52
TO MANAGEMENTNETWORK SWITCH
TO CLUSTER SWITCH
TO DATA NETWORKSWITCH
34
7-ModeAN
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
N
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
1
52
TO MANAGEMENTSUBNET
TO DATA NETWORK SWITCH
3
-
Single controller model Double controller model
Double controller modelSingle controller model
Single controller model
Cabling FAS2554 systemswith NO external storage
Cabling FAS2554systems WITH external storageDS424x disk shelves
Cabling FAS2554 systems WITH external storageDS2246 disk shelves
STOP HERE. If you have NO external storage, skip to .
No additional cabling required for a single controller.
Cable storage (Choose option A, B, or C below) 3
A
B
C
For additional congurations, see HELPFUL LINKS.
Ethernet cables
2
1
3
4
Daisy chain SAS ports
Connect rst SAS ports
Connect last SAS ports
Connect ACP ports on controllers to the disk shelves
Storage cables
1 2 3
Ethernet cables
2
1
3
4
Daisy chain SAS ports
Connect rst SAS ports
Connect last SAS ports
Connect ACP ports on controllers to the disk shelves
Storage cables
1 2 3
Connect SAS ports
Ethernet cables
Connect ACP ports
2
Storage cables
4 51 2 3
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
IOM6
All four power cords MUST be used for all units.
Install hardware2
Rack the system. Rail kit: follow instructions in the rail kit. OR System cabinet: install in the system cabinet.
Place the bezel over the front of the system.
Install system1
2
DO NOT power on system at this point.
3 Connect four power cords
Power cords
LIFTING HAZARDCAUTION
110 lbs (49.9 kg)
To reduce the weight of the disk shelf, remove the power supplies and controllers before lifting.
Use retaining clips
Use retaining clips
Cable controller for 7-Mode Data ONTAP (option A), switched clustered Data ONTAP (option B) or for switchless clustered Data ONTAP (option C)
See your network administrator for help connecting to your switch.
e0a
e0b
LNK LNK LNK LNK
e0a
e0b
LNK LNK LNK LNK
If you are converting from a switchless to a switched conguration, see the appropriate migration manual in the Cluster Management and Interconnect Switches library on the NetApp Support Site.
4 51 2 3
Shelf ID display
Attention LEDPower LED
Bezel
FRONT VIEWOF SYSTEM
BACK VIEWOF SYSTEM
PCM Attention LED
SAS ports (2) e0c-e0f 10 GbE Ethernet ports or 0c-0f Fibre Channel ports(SFP dependent)
One or two controller modulesPower supply
LEDs
Console port (Setting: 9600 N-8-1)
Remote/Node Management port(wrench icon)
ACP port(locked wrench icon)
Gigabit Ethernet ports (2)
NVMEM LED
Attach cable management arms.
Connect port e0c to the data switch.NOTE: Port e0c is required; other ports are available if needed.
Connect the wrench port to the management or subnet switch.
For option B onlyConnect port e0e | 0e and port e0f | 0f to the cluster switch.
For option C onlyConnect port e0e | 0e to port e0e | 0e and e0f | 0f to e0f | 0f.
Strap the cables to the cablemanagement arms.
5
1
2
Network cables3
B4 10 GbE cables
10 GbE cables
C4 10 GbE cables
Switchless clustered Data ONTAP
C
N
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
N
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
1
52
TO MANAGEMENTNETWORK SWITCH
TO DATA NETWORK SWITCH
34
Switched clustered Data ONTAP
B
N
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
N
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
1
52
TO MANAGEMENTNETWORK SWITCH
TO CLUSTER SWITCH
TO DATA NETWORKSWITCH
34
7-ModeAN
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
N
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
1
52
TO MANAGEMENTSUBNET
TO DATA NETWORK SWITCH
3
-
Complete System Setup4
System Setup information: http://support.netapp.com/NOW/public/system_setup/
Controller and conguration examples; Universal SAS and ACP Cabling Guide: https://library.netapp.com/ecm/ecm_download_le/ECMM1280392
OnCommand System Manager documentation set: http://support.netapp.com/documentation/productlibrary/index.html?productID=61372
Data ONTAP 8 library: http://support.netapp.com/documentation/productlibrary/index.html?productID=30092
Licenses: http://support.netapp.com/eservice/agree.do?moduleName=PROTOCOL
HELPFUL LINKSVisit the NetApp web site for more information.
Net
Ap
p
sup
po
rt s
ite
Complete conguration5
Create an account. Register your system. Get your license keys.
Register at support.netapp.com1
Provision more storage. Congure other protocols, data protection, and AutoSupport. Set up Service Processor and Remote Support Agent.
Download OnCommand System Manager From http://support.netapp.com/NOW/cgi-bin/software/
3
Download and run Cong AdvisorFrom http://support.netapp.com/NOW/download/tools/cong_advisor/
2
41 2 3 5
51 2 3 4
All four power supplies MUST be powered on.
CAUTION
31
42
CAUTION
31
42
CAUTION
31
42
CAUTION
31
42
Disconnect allsupply power forcomplete isolation.
Disconnect allsupply power forcomplete isolation.
Disconnectallsupplypowerforcompleteisolation.
Disconnectallsupplypowerforcompleteisolation.
CAUTION
31
42
Disconnect allsupply power forcomplete isolation.
CAUTION
31
42
Disconnectallsupplypowerforcompleteisolation.
CAUTION
31
42
Disconnectallsupplypowerforcompleteisolation.
CAUTION
31
42
Disconnect allsupply power forcomplete isolation.
CAUTION
31
42
Disconnect allsupply power forcomplete isolation.
e0a
e0b
LNK LNK LNK LNK
e0a
e0b
LNK LNK LNK LNK
2 4 6 8
1 3 5 7
10 12 14 16
9 11 13 15
12
11
14
13
16
15
6
5
8
7
10
9
2
1
4
31000/100/10MLNK /
1000/100/10MLNK /
MANAGEMENT SUBNET
WINDOWS CLIENT
Subnet
FAS2554 SYSTEM
e0a
e0b
LNK LNK LNK LNK
e0a
e0b
LNK LNK LNK LNK
Power on all external storage ONLY 3
Install System Setup* software on the Windows client
4
Cable Windows client to the same network as your controllers2
Complete conguration worksheet Available in the box or at http://support.netapp.com/NOW/public/system_setup/
1
*If you cannot use System Setup, see the Data ONTAP Software Setup Guide
the system.
When directed, power on your system (or repower).
Wait for discover to complete. Up to 8 minutes.
Enter the values from the conguration worksheet into System Setup.*
Start System Setup software5
Installation and Setup InstructionsFAS2554 Systems
Microsoft Windows clientRuns the software to congure
your storage system
ScrewdriverAdditional network cables
For connecting your storage to your network switch and Microsoft Windows client
Rack space - 4U
Download:
You provide:
System Setup Software: http://support.netapp.com/NOW/public/system_setup/ OnCommand System Manager: http://support.netapp.com/NOW/cgi-bin/software/
Prepare for installation1 4 51 2 3
Power cablesConguration
worksheet Serial cable not needed for this conguration
Starter network, storage, and 10 GbE cables
In the box:
http://support.netapp.com/NOW/cgi-bin/software/http://support.netapp.com/NOW/public/system_setup/https:/library.netapp.com/ecm/ecm_download_file/ECMM1280392http://support.netapp.com/documentation/productlibrary/index.html?productID=61372http://support.netapp.com/documentation/productlibrary/index.html?productID=30092http://support.netapp.com/eservice/agree.do?moduleName=PROTOCOLhttp://support.netapp.com/NOW/download/tools/config_advisor/http://support.netapp.com/NOW/public/system_setup/