EXECUTIVE BRIEFING CENTER 1 Executive Briefing Center 2.1 These guidelines are the general design standards for all Dell global projects. Please see the standard below for regional specific details that may vary from location to location. PLANNING AND REQUIREMENTS General Requirements Configuration will vary based on building or suite location, size and needs. Awards displays are not included in these environments as they do not align with the spirit of the Dell brand Security – suites within larger buildings to be secured separately during non-business hours. Each EBC will have the following areas: • Lobby/reception • Lounge/gathering space • Dining/food service area • Meeting and briefing rooms • Phone room • Support spaces • Restrooms Planning Specifics 1. Lobby/Reception: a. Reception desk per Lobby/Reception standards b. Task seating for reception staff to comply with all workstation seating requirements. c. Wall behind desk finished with wood (walnut) slat detail with Dell Technologies logo and “Executive Briefing Center”. See elevation in Drawings section. i. When spaces are combined, text should read “Executive Briefing & Solution Center” d. Electronic display/digital signage to comply with technology standards - Dell to provide Overview Customer facing spaces should be bright, friendly and branded appropriately. These Executive spaces should have an open gathering space and include required briefing, presentation and support spaces. Dell products will be showcased, and the digital experience should utilize Dell technologies throughout. The overall design is to be modern and clean. The EBC and Customer Solutions Center could be combined into one space to create an Executive Briefing and Solutions Center, depending on location. DESIGN STANDARDS | WORKPLACE ENVIRONMENTS Santa Clara, CA

Transcript of 2.1 Executive Briefing Centerdellbuildingstandards.com/Dell_GlobalStandards_EBC.pdf · DESIGN...

Page 1: 2.1 Executive Briefing Centerdellbuildingstandards.com/Dell_GlobalStandards_EBC.pdf · DESIGN STANDARDS WORPLACE ENIRONMENTS EECUTIVE BRIEFING CENTER 2 e. Purpose statement only to

DESIGN STANDARDS | WORKPLACE ENVIRONMENTS EXECUTIVE BRIEFING CENTER 1

Executive Briefing Center2.1

These guidelines are the general design standards for all Dell global projects. Please see the standard below for regional specific details that may vary from location to location.

PLANNING AND REQUIREMENTSGeneral Requirements• Configuration will vary based on building or suite location, size and needs.• Awards displays are not included in these environments as they do not align with the spirit of the Dell brand• Security – suites within larger buildings to be secured separately during non-business hours.• Each EBC will have the following areas: • Lobby/reception • Lounge/gathering space • Dining/food service area • Meeting and briefing rooms • Phone room • Support spaces • Restrooms

Planning Specifics 1. Lobby/Reception: a. Reception desk per Lobby/Reception standards b. Task seating for reception staff to comply with all workstation seating requirements. c. Wall behind desk finished with wood (walnut) slat detail with Dell Technologies logo and “Executive Briefing Center”. See elevation in Drawings section. i. When spaces are combined, text should read “Executive Briefing & Solution Center” d. Electronic display/digital signage to comply with technology standards - Dell to provide

Overview

Customer facing spaces should be bright,

friendly and branded appropriately. These

Executive spaces should have an open

gathering space and include required

briefing, presentation and support spaces.

Dell products will be showcased, and

the digital experience should utilize Dell

technologies throughout. The overall

design is to be modern and clean. The

EBC and Customer Solutions Center could

be combined into one space to create an

Executive Briefing and Solutions Center,

depending on location.

DESIGN STANDARDS | WORKPLACE ENVIRONMENTS

Santa Clara, CA

Page 2: 2.1 Executive Briefing Centerdellbuildingstandards.com/Dell_GlobalStandards_EBC.pdf · DESIGN STANDARDS WORPLACE ENIRONMENTS EECUTIVE BRIEFING CENTER 2 e. Purpose statement only to

DESIGN STANDARDS | WORKPLACE ENVIRONMENTS EXECUTIVE BRIEFING CENTER 2

e. Purpose statement only to be used if the EBC lobby/ reception is also a Dell building lobby/reception or if the EBC is not included within a Dell building. Refer to Lobby/ Reception standards. f. Guest seating g. Optional biophilic elements, such as a green/plant wall feature2. Lounge: a. Variety of lounge seating groups, depending on space needs and configuration b. Media wall to comply with technology standards - Dell to provide c. View of lab (only if combined with CSC) d. Artwork e. Optional biophilic elements, such as a green/plant wall feature 3. Dining/food service area: a. To be coordinated with EBC Catering contact b. Option for appropriate food service seating, if space allows. • bar height tables and chairs • built in counter with stools, depending on space allowance c. Include counter space, or standing height table space, to be used for self-service dining arrangements d. Artwork4. Meeting rooms: a. Multiple rooms in variety of sizes, to be coordinated with EBC contact b. Walnut wood tables with power and technology. See furniture section for table details. c. High back, executive style conference chairs d. Additional seating at room perimeter e. Millwork/Joinery f. Monitors and AV per EBC IT standards

g. Glass marker boards, wall mounted h. Artwork5. Phone room: a. As needed for guest use b. Artwork6. Support spaces as needed, to be coordinated with EBC contact a. Luggage and coat storage b. General storage c. Food preparation area d. Catering kitchen e. Staff work room with workstations as needed f. IT room7. Restrooms: a. Within suite if space and budget allow b. Follow restroom standards for new construction.

GENERAL INFORMATIONSpace Design• All furniture and finish selections to be reviewed and approved by Global Space Planning. Selections to be coordinated with the PMO budget and schedule.• Walls: • White painted walls (general) • Accent brick tile in white/grey, distressed finish to be used strategically throughout the space • example: floor to ceiling within lounge • example: backsplash within dining/food service areas & above counters

Lounge Round Rock, TX

Page 3: 2.1 Executive Briefing Centerdellbuildingstandards.com/Dell_GlobalStandards_EBC.pdf · DESIGN STANDARDS WORPLACE ENIRONMENTS EECUTIVE BRIEFING CENTER 2 e. Purpose statement only to

DESIGN STANDARDS | WORKPLACE ENVIRONMENTS EXECUTIVE BRIEFING CENTER 3

• Floors: • Textured, walnut wood look, commercial grade, vinyl plank flooring. Not to be installed at an angle or herringbone pattern. • Carpet tile in medium gray tones with texture and subtle pattern • Use integrated, thin profile, metal flooring transitions between flooring materials• Wall Base: • Base to be white and blend with the walls, architectural 6” or 150mm base• Ceilings: • Appropriate mix of large-scale acoustical ceiling tiles and soffits to create opportunities for lighting and architectural features • Ceiling changes can help to delineate seating and other functional areas within the open spaces• Glazing: • Floor to ceiling glass to be used at meeting room fronts. • Film to be applied at each room with either a 4’-0” or 1200mm opaque band or a 6’-0” or 1800 mm gradient film. • Sidelights: Provide minimum 18”-36” (500mm-900mm) wide, full height glazed section adjacent to door, if full glazing is not achievable for enclosed areas. • 9’ (3000mm) maximum height, glass wall with wood door, 3’ (900mm) frosted film on glass, if area is enclosed. Glass wall(s) can be traditional construction or an architectural wall system. • Window film to be provided on sidelights to match film on full glazing.• Doors: • Solid core, walnut wood door • Typically, 3’-0” x 8’-0” or 900mm x 2400mm doors; coordinate with local codes and requirements. • Hardware to be passage lever, 1-1/2 pair hinges, silencers, and floor mounted doorstop or building standard• Lighting, Power and Mechanical- refer to Building Standards • Decorative Lighting – larger scale, decorative chandeliers/ pendants over lounge seating areas. No decorative lighting at reception desk. See Reception and Lobby section. • Direct/Indirect pendant fixture with dual switching, typical.• Other: • Window coverings: If Meeting rooms are placed along exterior walls, provide electrically operated room darkening shades. Manual shades are acceptable if budget does not allow for electric. • Artwork: Preference is for original, commissioned, local art. All art must be coordinated and approved through the Dell Brand team.

• Optional biophilic elements such as green wall may be considered for these spaces• Millwork/Joinery • Walnut finish laminate or wood doors/drawers • White quartz solid surface counter material • Locking cabinets • Lower cabinets only • Integrated refrigerator within millwork, locations to be coordinated with EBC contact • Provide built in trash and recycle bins • Provide appropriate grommets for coffee machines and other equipment (specified by the business)• Equipment: • Lounge • Coffee and beverage equipment, typically provided by the Business Unit • Built in, under counter refrigerator, with front face to match millwork/joinery. Specific model to be coordinated per location • Sink, optional depending on overall design • Dining/food service area • Sink, optional depending on overall design • Coffee and beverage equipment, typically provided by the Business Unit • Built in, under counter refrigerator, with front face to match millwork/joinery, specific model to be coordinated per location • Bain-marie or food warmer, size and quantities to be coordinated with EBC food contact • Meeting rooms • Built in, under counter refrigerator, with front face to match millwork/joinery, specific model to be coordinated per location. • Other • Food preparation or catering kitchen spaces to be coordinated on a per site basis with the EBC food contact• Furniture: • Concept – Modern industrial with mid-century modern influences and walnut wood accents with timeless or classic fabrics that have a variety of luxurious textures. Textures are preferred over patterns. Acceptable patterns and materials include leather, wool, pinstripes, etc. • Colors - should be within the Brand standards color families with preference towards deep/rich shades of blue, green, and greys. Black is not acceptable. • Bright colors to be used at a minimum as accents within accessories.• Areas: • Lobby/Reception • Reception Desk: • Walnut wood laminate and white quartz solid surface materials

Page 4: 2.1 Executive Briefing Centerdellbuildingstandards.com/Dell_GlobalStandards_EBC.pdf · DESIGN STANDARDS WORPLACE ENIRONMENTS EECUTIVE BRIEFING CENTER 2 e. Purpose statement only to

DESIGN STANDARDS | WORKPLACE ENVIRONMENTS EXECUTIVE BRIEFING CENTER 4

• Designed per Reception and Lobby standards • Size and Storage needs to be determined per site • Guest seating should be lounge style postures with no more than two seating types (wing chairs, sofas, guest chairs, benches, etc.) within a lobby/reception area. • Seating arrangements should include coffee and occasional tables, if space allows. • Task seating for reception staff to follow all ergonomic, safety and sustainability requirements for workstation task seating. • Chair(s) to be light or medium grey finish. • Lounge/gathering space • Furniture should have a variety of postures (lounge, tables with seating, bar height tables with stools, etc.) and a variety of types (wing chairs, sofas, guest chairs, benches, etc.). • Seating arrangements should feature this variety and include coffee and occasional tables. • Dining/food service area • Dining style furniture to include bar or standing height tables and stools with standard tables and chairs. • Tables can be walnut or white laminate with brushed, metal base. • Stools or chairs to be walnut with easily maintained upholstery. • Meeting and briefing rooms • Built-in benches finish to be walnut and fabric in neutral/warm grey tone. See elevation in Drawings section for reference. Bench may also be a furniture piece. • Tables – walnut veneer tables with perimeter power and data under or at table apron, not at table top, accessible for customers. • Coordinate quantity of power and data connections with EBC contact. • Mobile tables – used in spaces to be reconfigured and where flexibility is needed. • Finishes to match standard meeting room tables. Include modesty panels in wood or brushed metal to match table base. • Each table is required to have one power outlet and one USB connection per seat. • Power and data access should be located at the table top and should retract when not in use. • Tables to have integrated cable management. • Chairs – thin profile, high back, executive style, conference chairs in medium gray leather (or leather look) fabric. • Arms and base to be brushed metal or matte grey metal.

• Black is not acceptable. • Phone room • Lounge chair • Small side table • Support spaces • Workstation(s) - Workstations, office and/or staff areas to be determined per site. Refer to Workstation standards.

Ergonomics, Safety and Sustainability• Refer to the EHS and Sustainability design criteria for ergonomic design of furniture.• Safety: Refer to the EHS and Sustainability design criteria, including but not limited to: walking surfaces, electrical service, cord management to prevent tripping hazards. • Provide adequate space to account for safe movement and delivery of paper. • Provide adequate space for both secure document collection and recycle paper collection.• Sustainability: Refer to the EHS and Sustainability design criteria, including but not limited to materials, installation, and energy efficient lighting. • Provide for adequate waste segregation and signage for recycled paper collection.

Technology• Security – coordinated through Dell IT and physical security for specific requirements per location• Media Wall(s) – to be used throughout space, typically within lounge environments, determined by business unit• Digital displays – per EBC/CSC standards• Digital room signage – per EBC/CSC standards

Signage• Dell Signage• Digital Signage• Wayfinding• Room Identifier

Specialties and Equipment

Design References• Building Standards• Brand Guidelines: Refer to https://brand.delltechnologies.com/dell-facilities/ for Dell Brand Guidelines.• EHS and Sustainability Design Criteria: Refer to EHS documentation• IT Standards

Page 5: 2.1 Executive Briefing Centerdellbuildingstandards.com/Dell_GlobalStandards_EBC.pdf · DESIGN STANDARDS WORPLACE ENIRONMENTS EECUTIVE BRIEFING CENTER 2 e. Purpose statement only to

DESIGN STANDARDS | WORKPLACE ENVIRONMENTS EXECUTIVE BRIEFING CENTER 5

DIAGRAMS | DRAWINGSExecutive Briefing Center

BRIEFINGROOM 8

STORAGE

STOR

STAIR VESTIBULE A

PROJECTION ROOM

PROJECTION ROOM

BRIEFING ROOM 4

CORR

AMPHITHEATER

BRIEFING ROOM 1

EBC LOUNGE

AV CLOSET

BRIEFING ROOM 3

PHONE RM

COPY

PHONE RM

CORRIDOR

RECEPTION

SHOWER

WO

ME

N’S

R

ES

TR

OO

M

ME

N’S

R

ES

TR

OO

M

JAN

ITO

R

CLO

SE

T

WOMEN’S RESTROOM

ME

N’S

R

ES

TR

OO

M

OFFICE

BRIEFING ROOM 2ELEC

BRIEFING ROOM 15

AV

CLO

SE

T

STOR CLST

PHONE RM

PHONE RM

PHONE RM

COAT CLST BRIEFING ROOM 14

TV STUDIO

STOR CLST

LUGGAGE STORAGE

TE

LEP

RE

SE

NC

E

RO

OM

STAIR VESTIBULE BELECTRICAL

STORAGE

SPRINKLER / GAS

FREIGHT ELEVATOR

ELECTRICAL

LOADING DOCK

PROJECTION ROOM

STORAGE

BRIEFING ROOM 9

EBC LOUNGE

BRIEFING ROOM 10

V CLOSET

BRIEFINGROOM 6

BRIEFINGROOM 7

CORRIDOR

BRIEFINGROOM 11

BRIEFINGROOM 12

TELEPHONE ROOM

PROJECTION ROOM

STORAGE

ELEV PUMP RM

ELEVATOR

Executive Briefing Center Floor Plan Hopkinton, MA

Page 6: 2.1 Executive Briefing Centerdellbuildingstandards.com/Dell_GlobalStandards_EBC.pdf · DESIGN STANDARDS WORPLACE ENIRONMENTS EECUTIVE BRIEFING CENTER 2 e. Purpose statement only to

DESIGN STANDARDS | WORKPLACE ENVIRONMENTS EXECUTIVE BRIEFING CENTER 6

DIAGRAMS | DRAWINGSExecutive Briefing Center

Executive Briefing & Solution Center Santa Clara, CA

BRIEFING ROOM

BRIEFING ROOM

CATERING

BRIEFING ROOM

OEM/IOT ROOMVIRTUAL REALITY/PRODUCT DISPLAY

STORAGE

RACK/DEMO LAB RACK/DEMO LAB

RESTROOM

RESTROOM

EBC LOUNGE

BRIEFING ROOM BRIEFING ROOM

CATERING

SERVERY

EBC LOUNGE

BRIEFING ROOM

STORAGE

BRIEFING ROOM

PRODUCT DISPLAY

COMBINED EBC AND CSC

RECEPTION

Page 7: 2.1 Executive Briefing Centerdellbuildingstandards.com/Dell_GlobalStandards_EBC.pdf · DESIGN STANDARDS WORPLACE ENIRONMENTS EECUTIVE BRIEFING CENTER 2 e. Purpose statement only to

DESIGN STANDARDS | WORKPLACE ENVIRONMENTS EXECUTIVE BRIEFING CENTER 7

36x3

636

x42

36x4

236

x42

36x4

236

x36

36x3

636

x36

30x1

830

x18

30x1

836

x18

36x1

836

x18

36x1

836

x18

36x6

0

36x6

0

36x6

0

24x6

024

x60

24x6

024

x60

24x6

024

x60

36x6

0

36x6

0

36x6

0

DIAGRAMS | DRAWINGSExecutive Briefing Center

Executive Briefing Center Floor Plan Round Rock, TX

AV EQUIP.ROOM

ELE

CT

RIC

AL

ST

OR

AG

E

IT EQUIP. ROOMMEETING ROOM MEETING ROOM MEETING ROOM

EBCSTAFF

LUGGAGEMEETING

ROOMEBC LOUNGE

ME

ET

ING

RO

OM

ME

ET

ING

RO

OM

EBC LOUNGE

RESTROOM

RESTROOM

COMBINED EBC AND CSC RECEPTIONTRAINING

ROOM

MEETINGROOM

SE

RV

ER

Y

KITCHEN

Page 8: 2.1 Executive Briefing Centerdellbuildingstandards.com/Dell_GlobalStandards_EBC.pdf · DESIGN STANDARDS WORPLACE ENIRONMENTS EECUTIVE BRIEFING CENTER 2 e. Purpose statement only to

DESIGN STANDARDS | WORKPLACE ENVIRONMENTS EXECUTIVE BRIEFING CENTER 8

DIAGRAMS | DRAWINGSExecutive Briefing Center

Typical Media Wall Elevation Slat Wall Elevation

MEDIA WALL- RECESSED WITHIN SURROUNDING WALL.COMPLY WITH TECHNOLOGY STANDARDS

SOLID WOOD SURROUND-WALNUT FINISH

ACCENT BRICK TILE IN WHITE/GRAY, DISTRESSED FINISH INSTALLED FLOOR TO CEILING SURROUNDING MEDIA WALL

WOOD SLAT WALL BEHIND RECEPTION DECK. FLOOR TO CEILING HEIGHT WHERE APPLICABLE- WALNUT FINISH

EXECUTIVE BRIEFING CENTER

Page 9: 2.1 Executive Briefing Centerdellbuildingstandards.com/Dell_GlobalStandards_EBC.pdf · DESIGN STANDARDS WORPLACE ENIRONMENTS EECUTIVE BRIEFING CENTER 2 e. Purpose statement only to

DESIGN STANDARDS | WORKPLACE ENVIRONMENTS EXECUTIVE BRIEFING CENTER 9

DIAGRAMS | DRAWINGSExecutive Briefing Center

Built In Bench ElevationTypical Millwork Elevation

BENCH CUSHION AND BACK AT APPROPRIATE BENCH HEIGHT WITH FABRIC IN NEUTRAL/WARM GRAY TONE. BENCH MAY ALSO BE A FURNITURE PIECE.

SOLID WOOD SURROUND-WALNUT FINISH

WOOD SLAT WALL- WALNUT FINISH

PAINTED WALLS, BOTH SIDES

SINK, OPTIONAL DEPENDING ON OVERALL DESIGN AND LOCATION OF MILLWORK

BUILT IN, UNDER COUNTER REFRIGERATOR WITH FRONT FACE TO MATCH MILLWORK/JOINERY

KNEE SPACE PER LOCAL CODES

INCLUDE BUILT IN TRASH AND RECYCLE BINS

MILLWORK/JOINERY:WALNUT FINISH LAMINATE OR WOOD DOORS AND DRAWERSLOWER CABINETS ONLYLOCKING CABINETS

COFFEE AND BEVERAGE EQUIPMENT TYPICALLY PROVIDED BY THE BUSINESS UNIT. COORDINATE LOCATIONS, WATER AND POWER ACCORDINGLY. PROVIDE GROMMETS IN THE COUNTERTOP AS NECESSARY TO ACCOMMODATE EQUIPMENT.

ACCENT BRICK TILE IN WHITE/GRAY, DISTRESSED FINISH INSTALLED TOP OF COUNTER TO CEILING ABOVE MILLWORK/JOINERY

WHITE QUARTZ SOLID SURFACE COUNTER MATERIAL

Page 10: 2.1 Executive Briefing Centerdellbuildingstandards.com/Dell_GlobalStandards_EBC.pdf · DESIGN STANDARDS WORPLACE ENIRONMENTS EECUTIVE BRIEFING CENTER 2 e. Purpose statement only to

DESIGN STANDARDS | WORKPLACE ENVIRONMENTS EXECUTIVE BRIEFING CENTER 10

PHOTOS

Lobby / Reception Area Round Rock, TX

Lounge Santa Clara, CA

Page 11: 2.1 Executive Briefing Centerdellbuildingstandards.com/Dell_GlobalStandards_EBC.pdf · DESIGN STANDARDS WORPLACE ENIRONMENTS EECUTIVE BRIEFING CENTER 2 e. Purpose statement only to

DESIGN STANDARDS | WORKPLACE ENVIRONMENTS EXECUTIVE BRIEFING CENTER 11

PHOTOS

Lounge Round Rock, TX

Lounge - Media Wall Round Rock, TX

Page 12: 2.1 Executive Briefing Centerdellbuildingstandards.com/Dell_GlobalStandards_EBC.pdf · DESIGN STANDARDS WORPLACE ENIRONMENTS EECUTIVE BRIEFING CENTER 2 e. Purpose statement only to

DESIGN STANDARDS | WORKPLACE ENVIRONMENTS EXECUTIVE BRIEFING CENTER 12

PHOTOS

Meeting / Briefing Room Santa Clara, CA

Meeting / Briefing Room Round Rock, TX

Page 13: 2.1 Executive Briefing Centerdellbuildingstandards.com/Dell_GlobalStandards_EBC.pdf · DESIGN STANDARDS WORPLACE ENIRONMENTS EECUTIVE BRIEFING CENTER 2 e. Purpose statement only to

DESIGN STANDARDS | WORKPLACE ENVIRONMENTS EXECUTIVE BRIEFING CENTER 13

PHOTOS

Meeting / Briefing Room Round Rock, TX