2019 CPS Energy Service Standards Site Ready · Clear the service location of all water and drain...
Transcript of 2019 CPS Energy Service Standards Site Ready · Clear the service location of all water and drain...
![Page 1: 2019 CPS Energy Service Standards Site Ready · Clear the service location of all water and drain lines, and underground facilities; including septic systems, culverts, irrigation](https://reader036.fdocuments.net/reader036/viewer/2022071512/6132f2cedfd10f4dd73ac64c/html5/thumbnails/1.jpg)
2019 CPS Energy Service Standards
Site Ready
Underground Service – Site Ready Process ................................................................................................... 2
Underground Service – Site Ready Diagrams ................................................................................................ 3
Overhead Service – Site Ready Process ......................................................................................................... 6
Overhead Service – Site Ready Diagrams ...................................................................................................... 7
![Page 2: 2019 CPS Energy Service Standards Site Ready · Clear the service location of all water and drain lines, and underground facilities; including septic systems, culverts, irrigation](https://reader036.fdocuments.net/reader036/viewer/2022071512/6132f2cedfd10f4dd73ac64c/html5/thumbnails/2.jpg)
Underground Service – Site Ready Process
Follow the steps to prepare your site for inspection:
◻ Install all equipment in compliance with the diagrams below.
◻ If you are digging your own trench, ensure it complies with Trench Design diagram below.
◻ Ensure the grade along the underground service route is within 6 inches of final grade.
◻ Securely mount electric meter loop and meter can on the structure’s wall.
◻ Stub gas structure pipe out 26 inches above final grade.
◻ If you are installing gas service, ensure your home interior lines and appliances are ready for either your city’s
Gas Inspection or CPS Energy’s Gas Rough-in Inspection, depending on your location.
In addition to infrastructure preparation, ensure that you:
◻ Clear the service location of all water and drain lines, and underground facilities; including septic systems,
culverts, irrigation systems, underground wiring, and other impediments.
◻ Clear all obstructions and/or debris from cable, gas, transformer, secondary enclosure, and meter location route.
◻ Sign and return any required easements to CPS Energy.
![Page 3: 2019 CPS Energy Service Standards Site Ready · Clear the service location of all water and drain lines, and underground facilities; including septic systems, culverts, irrigation](https://reader036.fdocuments.net/reader036/viewer/2022071512/6132f2cedfd10f4dd73ac64c/html5/thumbnails/3.jpg)
Underground Service – Site Ready Diagrams
![Page 4: 2019 CPS Energy Service Standards Site Ready · Clear the service location of all water and drain lines, and underground facilities; including septic systems, culverts, irrigation](https://reader036.fdocuments.net/reader036/viewer/2022071512/6132f2cedfd10f4dd73ac64c/html5/thumbnails/4.jpg)
![Page 5: 2019 CPS Energy Service Standards Site Ready · Clear the service location of all water and drain lines, and underground facilities; including septic systems, culverts, irrigation](https://reader036.fdocuments.net/reader036/viewer/2022071512/6132f2cedfd10f4dd73ac64c/html5/thumbnails/5.jpg)
![Page 6: 2019 CPS Energy Service Standards Site Ready · Clear the service location of all water and drain lines, and underground facilities; including septic systems, culverts, irrigation](https://reader036.fdocuments.net/reader036/viewer/2022071512/6132f2cedfd10f4dd73ac64c/html5/thumbnails/6.jpg)
Overhead Service – Site Ready Process
Follow the below steps to prepare your site for inspection:
◻ Install all equipment in compliance with the diagrams below or with the design approved by your CPS
Representative.
◻ Ensure the grade along the underground service route is within 6 inches of final grade.
◻ Securely mount electric meter loop and meter can on the structure’s wall.
◻ Stub gas structure pipe out 26 inches above final grade.
◻ If you are installing gas service, ensure your home interior lines and appliances are ready for either your city’s
Gas Inspection or CPS Energy’s Gas Rough-in Inspection, depending on your location.
In addition to infrastructure preparation, ensure that you:
◻ Clear the service location of all water and drain lines, and underground facilities; including septic systems,
culverts, irrigation systems, underground wiring, and other impediments.
◻ Clear all obstructions and/or debris from cable, gas, transformer, secondary enclosure, and meter location route.
◻ Sign and return any required easements to CPS Energy.
![Page 7: 2019 CPS Energy Service Standards Site Ready · Clear the service location of all water and drain lines, and underground facilities; including septic systems, culverts, irrigation](https://reader036.fdocuments.net/reader036/viewer/2022071512/6132f2cedfd10f4dd73ac64c/html5/thumbnails/7.jpg)
Overhead Service – Site Ready Diagrams
![Page 8: 2019 CPS Energy Service Standards Site Ready · Clear the service location of all water and drain lines, and underground facilities; including septic systems, culverts, irrigation](https://reader036.fdocuments.net/reader036/viewer/2022071512/6132f2cedfd10f4dd73ac64c/html5/thumbnails/8.jpg)
![Page 9: 2019 CPS Energy Service Standards Site Ready · Clear the service location of all water and drain lines, and underground facilities; including septic systems, culverts, irrigation](https://reader036.fdocuments.net/reader036/viewer/2022071512/6132f2cedfd10f4dd73ac64c/html5/thumbnails/9.jpg)
![Page 10: 2019 CPS Energy Service Standards Site Ready · Clear the service location of all water and drain lines, and underground facilities; including septic systems, culverts, irrigation](https://reader036.fdocuments.net/reader036/viewer/2022071512/6132f2cedfd10f4dd73ac64c/html5/thumbnails/10.jpg)