Page 1: 2017 OBC STRUCTURAL OVERVIEW · 2017. 11. 16. · • Section 1609 Wind Loads • ASCE 7-10 is now based upon ultimate design wind speed values, similar to seismic loading. • Ohio

2017 OBC STRUCTURAL OVERVIEW

Shayne O Manning, P.E., S.E., LEED AP

Page 2: 2017 OBC STRUCTURAL OVERVIEW · 2017. 11. 16. · • Section 1609 Wind Loads • ASCE 7-10 is now based upon ultimate design wind speed values, similar to seismic loading. • Ohio

Presentation Synopsis • The process by which the Ohio Board of Building Standards reviews

the changes proposed by IBC code updates, both the major issues on a three-year cycle plus the interim amendments, for the creation the Ohio Building Code.

• The 2017 OBC major changes, primarily in Chapter 16 and Chapter

34, are reviewed from not only the IBC 2015 changes that are incorporated into OBC and the Ohio amendments to IBC.

Page 3: 2017 OBC STRUCTURAL OVERVIEW · 2017. 11. 16. · • Section 1609 Wind Loads • ASCE 7-10 is now based upon ultimate design wind speed values, similar to seismic loading. • Ohio

Open Parking Garages

• 406.5.2.1 Openings Below Grade • Ventilation requirements for below grade garage levels.

Presenter
Presentation Notes
Page 4: 2017 OBC STRUCTURAL OVERVIEW · 2017. 11. 16. · • Section 1609 Wind Loads • ASCE 7-10 is now based upon ultimate design wind speed values, similar to seismic loading. • Ohio

Storm Shelters • 423.3 & 423.4 Critical Emergency Operations & Group E

Occupancies • ICC 500, ICC/NSSA Standard for the Design and Construction of Storm Shelters

• Ohio falls within the ICC 250 mph tornado alley and, with the 2015 IBC, requires civil defense and most schools to have a storm shelter.

• Vult = 250 mph

Page 5: 2017 OBC STRUCTURAL OVERVIEW · 2017. 11. 16. · • Section 1609 Wind Loads • ASCE 7-10 is now based upon ultimate design wind speed values, similar to seismic loading. • Ohio

Lintel Bottom Flange Fire Protection

• 704.11 Bottom Flange Protection

• Lintels, angles, plates spanning not more than 6’-4” when part of primary structural frame.

• No limit when not part of primary structural frame.

Page 6: 2017 OBC STRUCTURAL OVERVIEW · 2017. 11. 16. · • Section 1609 Wind Loads • ASCE 7-10 is now based upon ultimate design wind speed values, similar to seismic loading. • Ohio

Exterior Wall Stability Bracing related to Fire Protection • 705.6 Structural Stability • Interior construction rating for bracing exterior rated walls.

Page 7: 2017 OBC STRUCTURAL OVERVIEW · 2017. 11. 16. · • Section 1609 Wind Loads • ASCE 7-10 is now based upon ultimate design wind speed values, similar to seismic loading. • Ohio

Single and Double Fire Walls • 706.2 Structural Stability • NFPA 221Standards for High Challenge Fire Walls, Fire Walls, and

Fire Barrier Walls. • Tied and Cantilevered Options addressed

Presenter
Presentation Notes
Page 8: 2017 OBC STRUCTURAL OVERVIEW · 2017. 11. 16. · • Section 1609 Wind Loads • ASCE 7-10 is now based upon ultimate design wind speed values, similar to seismic loading. • Ohio

Permanent Ladders • 1011.16 Ladders • Permanent ladders are

permitted for access in some situations.

• OMC Section 306.5 (Mechanical Code) for equipment access requirements.

Page 9: 2017 OBC STRUCTURAL OVERVIEW · 2017. 11. 16. · • Section 1609 Wind Loads • ASCE 7-10 is now based upon ultimate design wind speed values, similar to seismic loading. • Ohio

Construction Documents

• Section 1603 Construction Documents • Additional structural design loading required to be shown on the

drawings, including drifting snow loads and photovoltaic panel dead loads.

Page 10: 2017 OBC STRUCTURAL OVERVIEW · 2017. 11. 16. · • Section 1609 Wind Loads • ASCE 7-10 is now based upon ultimate design wind speed values, similar to seismic loading. • Ohio

Serviceability

• Table 1604.3 Deflection Limits • Clarifications for loading vs. allowable deflection for exterior walls

and interior partitions.

Page 11: 2017 OBC STRUCTURAL OVERVIEW · 2017. 11. 16. · • Section 1609 Wind Loads • ASCE 7-10 is now based upon ultimate design wind speed values, similar to seismic loading. • Ohio

Risk Category • 1604.5 Risk Category & Table 1604.5 Risk Category of Buildings and Other Structures • Occupancy Category is now Risk Category • OBC Table 1604.5, not ASCE 7-10 for Risk Categories

Page 12: 2017 OBC STRUCTURAL OVERVIEW · 2017. 11. 16. · • Section 1609 Wind Loads • ASCE 7-10 is now based upon ultimate design wind speed values, similar to seismic loading. • Ohio

Structural Wall Anchorage

• 1604.8.2 Structural Walls • Structural Walls anchorage as opposed to Walls • Anchor masonry walls into a “reinforced grouted structural element

of the wall”

Presenter
Presentation Notes
 
Page 13: 2017 OBC STRUCTURAL OVERVIEW · 2017. 11. 16. · • Section 1609 Wind Loads • ASCE 7-10 is now based upon ultimate design wind speed values, similar to seismic loading. • Ohio

Load Combinations

• Section 1605 Load Combinations • Wind Force Load combinations ultimate not ASD • Lateral pressures from fluids and earth.

Page 14: 2017 OBC STRUCTURAL OVERVIEW · 2017. 11. 16. · • Section 1609 Wind Loads • ASCE 7-10 is now based upon ultimate design wind speed values, similar to seismic loading. • Ohio

Live Loads

• Table 1607.1 Live Loads, Minimum Uniform and Concentrated • Stage and platform live loads revised • Helipad live loading added (see 1607.6 also) • Occupiable roofs clarified.

Page 15: 2017 OBC STRUCTURAL OVERVIEW · 2017. 11. 16. · • Section 1609 Wind Loads • ASCE 7-10 is now based upon ultimate design wind speed values, similar to seismic loading. • Ohio

Partition Loads • 1607.5 Partition Loads • Minimum 15 psf partition allowance is required unless specified live

load is 80 psf or greater. • Note seismic mass calculation effect

Presenter
Presentation Notes
Page 16: 2017 OBC STRUCTURAL OVERVIEW · 2017. 11. 16. · • Section 1609 Wind Loads • ASCE 7-10 is now based upon ultimate design wind speed values, similar to seismic loading. • Ohio

10,000# or Heavier Vehicle & Forklift Loading • 1607.7 Heavy Vehicle Loads • ODOT/AASHTO design or actual vehicle operational weight if larger • Impact and fatigue design criteria • Post Loading Capacity

Page 17: 2017 OBC STRUCTURAL OVERVIEW · 2017. 11. 16. · • Section 1609 Wind Loads • ASCE 7-10 is now based upon ultimate design wind speed values, similar to seismic loading. • Ohio

Façade Access Equipment

• 1607.9.3 & 1605.9.4 Elements Supporting Hoists and Lifeline Anchorages for Façade Access Equipment

• Specifies live loading for hoist supports and lifeline anchorages.

Page 18: 2017 OBC STRUCTURAL OVERVIEW · 2017. 11. 16. · • Section 1609 Wind Loads • ASCE 7-10 is now based upon ultimate design wind speed values, similar to seismic loading. • Ohio

Live Load Reduction

• 1607.10.2 Alternative Uniform Live Load Reduction • 1607.10.1 LL Reduction can be incorrectly interpreted

Page 19: 2017 OBC STRUCTURAL OVERVIEW · 2017. 11. 16. · • Section 1609 Wind Loads • ASCE 7-10 is now based upon ultimate design wind speed values, similar to seismic loading. • Ohio

Vegetative Roofs • 1607.12.3 Vegetative Roof Loads • Calculation of vegetative roof dead load is the saturated weight per

ASTM E 2397. • Also see Table 1607.1 for vegetative roof live loads.

Page 20: 2017 OBC STRUCTURAL OVERVIEW · 2017. 11. 16. · • Section 1609 Wind Loads • ASCE 7-10 is now based upon ultimate design wind speed values, similar to seismic loading. • Ohio

Photovoltaic Panel Systems • 1607.12.5 Photovoltaic Panel Systems & 1613.6 Ballasted Photovoltaic Panel Systems • Specific design requirements for PV panel installations.

Page 21: 2017 OBC STRUCTURAL OVERVIEW · 2017. 11. 16. · • Section 1609 Wind Loads • ASCE 7-10 is now based upon ultimate design wind speed values, similar to seismic loading. • Ohio

Wind Loading

• Section 1609 Wind Loads • ASCE 7-10 is now based upon ultimate design wind speed values,

similar to seismic loading. • Ohio Risk Category I, Vult = 105 mph • Ohio Risk Category II, Vult = 115 mph • Ohio Risk Category III & IV, Vult = 120 mph

Page 22: 2017 OBC STRUCTURAL OVERVIEW · 2017. 11. 16. · • Section 1609 Wind Loads • ASCE 7-10 is now based upon ultimate design wind speed values, similar to seismic loading. • Ohio

1920 Akron Building Code including State Building Code

Page 23: 2017 OBC STRUCTURAL OVERVIEW · 2017. 11. 16. · • Section 1609 Wind Loads • ASCE 7-10 is now based upon ultimate design wind speed values, similar to seismic loading. • Ohio

Rain Design Loading for Roofs

• Section 1611 Rain Loads 1105.2 & 1106.2 & 1106.3 of the Plumbing Code 1503.4 Roof Drainage • New requirements requires close coordination between the structural

engineer, architect, plumbing designer, and the construction details.

Page 24: 2017 OBC STRUCTURAL OVERVIEW · 2017. 11. 16. · • Section 1609 Wind Loads • ASCE 7-10 is now based upon ultimate design wind speed values, similar to seismic loading. • Ohio
Page 25: 2017 OBC STRUCTURAL OVERVIEW · 2017. 11. 16. · • Section 1609 Wind Loads • ASCE 7-10 is now based upon ultimate design wind speed values, similar to seismic loading. • Ohio

Amendments to ASCE 7 • 1613.5.1 Transfer of

Anchorage Forces into Diaphragm

• Permitted amendment to ASCE 7 to clarify diaphragm aspect ratio limitation to wood, structural panel, or untopped steel decks.

Page 26: 2017 OBC STRUCTURAL OVERVIEW · 2017. 11. 16. · • Section 1609 Wind Loads • ASCE 7-10 is now based upon ultimate design wind speed values, similar to seismic loading. • Ohio

Ice Loading • Section 1614 Atmospheric Ice Loads • New section for design loads for ice build up on sensitive structures. • See ASCE 7

Page 27: 2017 OBC STRUCTURAL OVERVIEW · 2017. 11. 16. · • Section 1609 Wind Loads • ASCE 7-10 is now based upon ultimate design wind speed values, similar to seismic loading. • Ohio

Chapter 17 Special Inspection and Tests • There have been numerous changes to requirements in this Chapter

which needs to be reviewed for each project.

Page 28: 2017 OBC STRUCTURAL OVERVIEW · 2017. 11. 16. · • Section 1609 Wind Loads • ASCE 7-10 is now based upon ultimate design wind speed values, similar to seismic loading. • Ohio

1920 Akron Building Code Including State Building Code

Page 29: 2017 OBC STRUCTURAL OVERVIEW · 2017. 11. 16. · • Section 1609 Wind Loads • ASCE 7-10 is now based upon ultimate design wind speed values, similar to seismic loading. • Ohio

Window and Door ASD Wind Pressures • 1709.5 Exterior Window and Door Assemblies • Specify wind design pressures on basis of allowable stress design.

Page 30: 2017 OBC STRUCTURAL OVERVIEW · 2017. 11. 16. · • Section 1609 Wind Loads • ASCE 7-10 is now based upon ultimate design wind speed values, similar to seismic loading. • Ohio

Foundation Stability due to Excavation Undermining

• 1803.5.7 & 1804.1 Excavation near Foundations • Clarifies that a registered design professional will assess the

shoring, underpinning, etc. required for excavation that could destabilize foundations.

Page 31: 2017 OBC STRUCTURAL OVERVIEW · 2017. 11. 16. · • Section 1609 Wind Loads • ASCE 7-10 is now based upon ultimate design wind speed values, similar to seismic loading. • Ohio
Page 32: 2017 OBC STRUCTURAL OVERVIEW · 2017. 11. 16. · • Section 1609 Wind Loads • ASCE 7-10 is now based upon ultimate design wind speed values, similar to seismic loading. • Ohio

OBC Chapters Referencing Materials

• Chapter 19 Concrete • Chapter 20 Aluminum • Chapter 21 Masonry • Chapter 22 Steel • Many of the OBC/IBC requirements have been removed since they

have been picked up in the respective ACI, AA, and AISC code/specifications.

Page 33: 2017 OBC STRUCTURAL OVERVIEW · 2017. 11. 16. · • Section 1609 Wind Loads • ASCE 7-10 is now based upon ultimate design wind speed values, similar to seismic loading. • Ohio

Chapter 19 - Concrete

• ACI 318-14 is now the referenced concrete design code • New ACI Chapters on Earthquake Resistant Structures and Design

and Durability Requirements. • ACI requirements for information which shall be shown in

construction documents.

Page 34: 2017 OBC STRUCTURAL OVERVIEW · 2017. 11. 16. · • Section 1609 Wind Loads • ASCE 7-10 is now based upon ultimate design wind speed values, similar to seismic loading. • Ohio

Concrete Anchor Design

• 1901.3 Anchoring to Concrete • OBC specifies that anchorage of CIP and post-installed anchors

shall be per ACI 318-14.

Page 35: 2017 OBC STRUCTURAL OVERVIEW · 2017. 11. 16. · • Section 1609 Wind Loads • ASCE 7-10 is now based upon ultimate design wind speed values, similar to seismic loading. • Ohio

CLT • 2303.1.4 Structural Glued Cross-Laminated Timber • CLT referenced to provisions in ANSI/APA PRG 320-2011.

Page 36: 2017 OBC STRUCTURAL OVERVIEW · 2017. 11. 16. · • Section 1609 Wind Loads • ASCE 7-10 is now based upon ultimate design wind speed values, similar to seismic loading. • Ohio

Wood Frame Construction Manual • Section 2309 WFCM • AWC WFCM - alternate design methodology of Risk Category I and

II structures

Page 37: 2017 OBC STRUCTURAL OVERVIEW · 2017. 11. 16. · • Section 1609 Wind Loads • ASCE 7-10 is now based upon ultimate design wind speed values, similar to seismic loading. • Ohio

Chapter 34 - Existing Buildings

• The OBC 2017 includes Chapter 34 • IBC has been gradually steering the existing building code

provisions to IEBC as a separate code for over 15 years and with 2015, Chapter 34 has been eliminated from IBC.

• OBC Chapter 34 updated with changes from 2015 IBC provisions from IEBC and ASCE 41 to reduce the seismic penalty for existing buildings in Ohio.

Page 38: 2017 OBC STRUCTURAL OVERVIEW · 2017. 11. 16. · • Section 1609 Wind Loads • ASCE 7-10 is now based upon ultimate design wind speed values, similar to seismic loading. • Ohio

Seismic Design Analysis

• 3401.5 Compliance with Seismic Forces • In general if a seismic evaluation is required according to Chapter

34 it shall be evaluated either using Chapter 16 or ASCE 41. • The ASCE 41 evaluation can be by using reduced seismic forces

from BSE-1-1E Earthquake Hazard Level. • Table 3401.5.2 ASCE 41 Seismic Performance Levels vs. Risk

Category

Page 39: 2017 OBC STRUCTURAL OVERVIEW · 2017. 11. 16. · • Section 1609 Wind Loads • ASCE 7-10 is now based upon ultimate design wind speed values, similar to seismic loading. • Ohio

Seismic Design for the Repair of Structures

• 3401.5.3 Compliance with Reduced Seismic Forces • When a seismic evaluation is required by 3405 Repairs, it is permitted

to use 75% of the specified seismic forces from Chapter 16.

Page 40: 2017 OBC STRUCTURAL OVERVIEW · 2017. 11. 16. · • Section 1609 Wind Loads • ASCE 7-10 is now based upon ultimate design wind speed values, similar to seismic loading. • Ohio

Additions to Existing Buildings • Section 3403 Additions • If Building Additions add loading to existing construction from dead

load, live load, snow load, wind, and/or seismic loads; provisions are stated for evaluation of these members.

• The intent is for an evaluation of the cumulative effects of additions and alterations since the original construction.

Page 41: 2017 OBC STRUCTURAL OVERVIEW · 2017. 11. 16. · • Section 1609 Wind Loads • ASCE 7-10 is now based upon ultimate design wind speed values, similar to seismic loading. • Ohio

Alterations of Existing Buildings

• Section 3404 Alterations • Similarly to 3403, the evaluation is required for existing construction

subjected to additional loading, as compared to original construction.

Page 42: 2017 OBC STRUCTURAL OVERVIEW · 2017. 11. 16. · • Section 1609 Wind Loads • ASCE 7-10 is now based upon ultimate design wind speed values, similar to seismic loading. • Ohio

Repairs to Existing Buildings

• Section 3405 Repairs • Criteria for evaluation and strengthening repair of structures due to

forces from dead load, live load, snow load, wind load, and/or earthquake load is dependent on what caused the need for a repair.

• Drifting snow load failure of a member - Repair the member to meet current Chapter 16 drifting snow requirements as a minimum.

Page 43: 2017 OBC STRUCTURAL OVERVIEW · 2017. 11. 16. · • Section 1609 Wind Loads • ASCE 7-10 is now based upon ultimate design wind speed values, similar to seismic loading. • Ohio

Change of Occupancy

• Section 3408 Change of Occupancy • Changes in occupancy potentially change the Risk Category and

therefore may require an evaluation and potential strengthening of the structure.

• There are exceptions in 3408.4 for upgrades required due to snow, wind, and seismic forces to minimize requirements for these upgrades.

Page 44: 2017 OBC STRUCTURAL OVERVIEW · 2017. 11. 16. · • Section 1609 Wind Loads • ASCE 7-10 is now based upon ultimate design wind speed values, similar to seismic loading. • Ohio

The 2017 Ohio Building Code is a living document

The Ohio Board of Building Standards welcomes your input.