What is a boiler?

Boilers use fuel to heat water or steam and circulate the hot water through pipes. Thehot water produced is then used to heat a building and/or produce hot water for personal or industrial use. For example a boiler used as a heating system in a home would have radiators in a house or part of a building. The boiler heats the water for use and also circulates that hot water through the pipes and the radiator, heating the rooms. A boiler uses circulated hot water whereas a furnace, found in many homes today, uses forced air and circulates it through vents.

Types of boilers include steam turbine, package boilers, steam generators, cleansteam packages, hot water heaters, hot oil heaters, boilers and vaporizers. A packageboiler is a boiler that is ordered with all necessary parts included, assembled and ready to use. Very little installation is required. Steam boilers are used to produce steam for industrial usage such as cleaning. Boilers vary in size and shape. A boiler used for a residence is going to be small enough to fit in the corner of a room, where are industrial boilers can be large enough to fill up an entire room. Depending on the amount of heat it needs to generate and what exactly it will be used for.

Refurbishing a boiler

If you now have a boiler and are considering replacing it you have a few options. Boilers have a general life of 30-40 years. If there are parts on your boiler that are not working you may consider getting it refurbished, buying a used boiler that has been refurbished already, or getting new parts. When a boiler is replaced it's often sent out to be remanufactured. The boiler is disassembled, cleaned, refurbished and then sent back out to operation or put on the market. The parts of the boiler are inspected and cleaned. If a part is no longer working and it is irreparable, it will be discarded, only parts that are safe and in working order are refurbished. It is commonfor brand new parts to be used with refurbished parts or systems. A boiler that has been refurbished can come out of the shop looking like new and work just as well as anew one, and for a much lower cost.

Other benefits

If the decision has been made to purchase a brand new boiler, consider sending your used boiler to get refurbished so that someone else can use it. Boilers can almost always be refurbished and recycled, if not for the whole boiler can usually be disassembled for parts. There may be a non-profit organization or church in your areathat is in need of a boiler but cannot afford to purchase a new one. Having a used boiler available to purchase or given as a donation, would be a huge help to any organization. The benefits of used boilers extend beyond that. Buying used boilers benefits the environment by helping to keep used appliances and materials out of landfills and it creates jobs at recycling and remanufacturing plants.

Page 3: BOILERdocshare02.docshare.tips/files/25397/253975236.pdf · 2017-01-24 · boiler at 120% with boiler steam stop valves closed (refer to Figure 3). These valves are discussed in detail

INTRODUCTION

The D-type boiler has been installed in U.S. Navy ships since 1950. Whether 600 psi or 1200 psi, D-type boiler construction is basically the same with a few exceptions, such as number of fuel oil burners and overall size and volume.

REFERENCES

(a) Boilers NSTM Chapter 221 (b) Fireman NAVEDTRA 10520 Series (c) Boiler Technician 3&2 NAVEDTRA 10535B (d) Principles of Naval Engineering 10788 H (e) Boiler Operation and Maintenance Manual NAVSEA 0951-LP-022-6010

INFORMATION

A. Main propulsion boilers provide steam to the main propulsion turbines and auxiliary services in order to supply all shipboard steam systems in accordance with demand. (refer to Figure 1). It is designated as a D-type boiler because of the relative positions of the drums and side header which form the letter D. All D-type boilers are designated as uncontrolled superheat boilers because all the steam generated by the boiler must pass through the superheater. Superheater outlet temperature is a result of the combustion gas flow in proportion to the total amount of steam flow through all ranges (0 - 120%). The design characteristics ensure that the temperature will stabilize at set point. The degree of superheat is calculated by subtracting steam drum temperature from the actual reading on the superheater outlet temperature gage. In this lesson we will examine the components of the boiler and then we will bring everything together by describinghow water and steam is generated and circulated through the boiler. The flow path of combustion gases through the boiler will also be discussed.

D TYPE BOILER

Page 4: BOILERdocshare02.docshare.tips/files/25397/253975236.pdf · 2017-01-24 · boiler at 120% with boiler steam stop valves closed (refer to Figure 3). These valves are discussed in detail

B. The economizer is a multi-pass heat exchanger located above the main generating bankat the base of the exhaust stack, so that combustion gas will give up a lot of its remaining heat to the incoming feedwater before passing out the stack (Refer to Figure 2) The incoming feedwater absorbs about 100°-200°F sensible heat from the exhaust gases. Finsare installed on the economizer tubes to increase the heating surface area further, helping to increase efficiency.

ECONOMIZER

Page 5: BOILERdocshare02.docshare.tips/files/25397/253975236.pdf · 2017-01-24 · boiler at 120% with boiler steam stop valves closed (refer to Figure 3). These valves are discussed in detail

C. The steam drum is located at the top of the boiler to provide an upper reservoir for the water covering the generating tube bank. Water is distributed from the steam drum to the lower drums and headers by pipes called downcomers. Generated steam is also collected and is separated from the water in the steam drum. Boilers are also equipped with safety valves to relieve excessive pressure. The valves are located on the steam drum and superheater outlet. They are designed to relieve sufficient pressure to safely steam the boiler at 120% with boiler steam stop valves closed (refer to Figure 3). These valves are discussed in detail in lesson 62B-206. D. Air vents or air cocks are installed on top of the steam drum to expel air from inside the steam drum during cold boiler light-off or when filling the boiler. The air vents or air cocks are shut when the boiler starts generating steam.

SAFETY VALVE CONFIGURATION

Page 6: BOILERdocshare02.docshare.tips/files/25397/253975236.pdf · 2017-01-24 · boiler at 120% with boiler steam stop valves closed (refer to Figure 3). These valves are discussed in detail

E. The internal fittings in the steam drum help distribute the water evenly throughout the drum, separate the generated steam from the water and remove moisture from the steam before it leaves the boiler (refer to Figure 4). 1. Lower baffle plates or apron plates Separate the incoming feedwater and generated steam and direct the steam to the separators. 2. Primary separators (cyclone separators) Separate most of the water from the steam bygiving it a cyclone or rotary motion so that the water particles are expelled from the steamby the centrifugal forces. These separators are vertically mounted in the steam drum so that the steam rises out the top and the water falls back into the steam drum. 3. Secondary separators (chevron dryers) Remove additional moisture from the steam by changing the direction of steam flow several times. The steam passes on but the moisture cannot make the direction change with the steam. These separators are mountedabove the primary separators and direct steam to the dry box which collects the steam at the top of the steam drum, directing it to the steam outlet piping to the superheater. 4. Feedwater leaves the economizer and enters the boiler through the internal feed pipe and becomes "boiler water." Perforations along the side of the feed pipe allow water to be distributed evenly throughout the steam drum (refer to Figure 4)

STEAM DRUM INTERNALS

Page 7: BOILERdocshare02.docshare.tips/files/25397/253975236.pdf · 2017-01-24 · boiler at 120% with boiler steam stop valves closed (refer to Figure 3). These valves are discussed in detail

5. Since suspended solids may accumulate on the surface of the water in the steam drum, there must be means of removing them. The surface blow pipe is used to remove these light suspended solids from the surface of the water and to reduce the total dissolved solid content of the boiler water. Suspended solids usually consist of oil, salt contaminants, or excessive treatment chemicals which can cause foaming on the water surface. Dissolved solids usually consist of salt contaminants and treatment chemicals that are in solution. F. The D-type boiler uses the principle of accelerated natural circulation to circulate waterthrough the boiler. To enable this principle to work, relatively cool water will naturally circulate through large diameter pipes to distribution points low in the boiler. The downcomers are these large diameter pipes connecting the steam drum with the water drum and lower headers to ensure proper circulation by delivering water from the steam drum to the water drum and lower headers. The downcomers are located between the inner and outer air casing to protect them from the direct radiant heat of the furnace. G. The water drum is located at the bottom of the boiler below the main generating bank and acts as a lower reservoir of water for distribution to the main generating bank. Also, this large drum serves as a collection point for solids (sludge) that precipitate to the bottom that are removed by bottom blowdown. H. The sidewall header is located along the furnace sidewall connecting sidewall tubes from the furnace floor to the steam drum. It distributes water to the sidewall tubes and provides another blowdown point for sludge removal. The sidewall tubes are two inch tubes which protect the boiler sidewall refractory from the direct heat of combustion and generate a small amount of steam. I. The lower rearwall header is located along the furnace rearwall from the furnace floor to the steam drum or upper header to provide a lower junction for rearwall tubes. It

Page 8: BOILERdocshare02.docshare.tips/files/25397/253975236.pdf · 2017-01-24 · boiler at 120% with boiler steam stop valves closed (refer to Figure 3). These valves are discussed in detail

distributes water to the rearwall tubes and provides yet another blowdown point for removal of sludge. The rearwall tubes are two inch tubes which protect the boiler rearwall refractory from the heat of combustion and generate some steam. NOTE: By using wall tubes, more of the heat in the furnace is absorbed by water and less refractory material is required, thereby increasing boiler efficiency and reducing the boiler weight. J. The upper rearwall header is often called the "floating header" because of its free-standing design. It is located along the rearwall of the furnace roof to provide an upper junction for the rearwall tubes. It collects the steam generated in the rearwall tubes and direct it to the steam drum through riser tubes. K. Riser tubes are large tubes located above the furnace roof to provide a connection between the upper rearwall header and the steam drum. L. Superheater screenwall tubes help protect the superheater from direct radiant heat of the furnace. The screen tubes consist of two to three staggered rows of two inch tubes which are usually connected from the steam drum to the water drum. Some boilers have a screenwall header installed parallel to the superheater along the furnace floor as a lower connection and a blowdown point for sludge. M. The steam passes through the superheater picking up sensible heat (about 300-400° F) which increases the energy of the steam, allowing it to perform more work. The superheater is composed of superheater headers which distribute steam to the superheater tubes or elements and direct it from the inlet to outlet piping. These headers and elementscan be either vertically or horizontally mounted. (Refer to Figure 5).

Page 9: BOILERdocshare02.docshare.tips/files/25397/253975236.pdf · 2017-01-24 · boiler at 120% with boiler steam stop valves closed (refer to Figure 3). These valves are discussed in detail

N. The bulk of the steam generated by the boiler is formed in the main generating bank because it has the largest heating surface. This is a large group of one inch tubes which run from the water drum to the steam drum and are located behind the superheater. O. Since these boilers are uncontrolled superheat and the plant is designed to use lower temperature steam in many applications to help reduce construction and maintenance costs, the steam needed for these services must pass through a desuperheater. The desuperheater is a multi-pass tube bundle which is located in the water drum in most boilers. There are several boilers which have the desuperheater in the steam drum. As the superheated steam passes through the tube bundle, it gives up heat to the boiler water in the water drum. P. The boiler is protected from the high temperatures of combustion by the refractory. Refractory lines the inside surface of the inner casing enclosing all of the furnace area andextending to the outer row of generating tubes. There are several different types of refractory which work together to protect the boiler. 1. Firebrick is a heavy casted refractory used as the outer layer of refractory and is exposed to the direct flames of combustion. It has poor insulating qualities, but it will withstand direct flame contact. 2. Insulating brick is a lightweight casted refractory used between the insulating block and firebrick. It has good insulating properties, but it will not withstand direct contact with flame.

Page 10: BOILERdocshare02.docshare.tips/files/25397/253975236.pdf · 2017-01-24 · boiler at 120% with boiler steam stop valves closed (refer to Figure 3). These valves are discussed in detail

3. Insulating block is a pressed fiber material used next to the inner casing. It has the highest insulating properties of the various refractory, but it will not withstand direct contact with flame. 4. Burner tiles are preformed refractory used to form burner cones around where the burner assembly protrudes into the furnace. Burner tiles are a specially shaped, heavy casted refractory used next to the insulating brick around the burner openings. They havepoor insulating qualities, but they will withstand direct flame contact.

5. High temperature castable refractory is used to fill in gaps in refractory or where shaping is needed to cover irregular shaped items. It is used to patch refractory or to smooth uneven areas between brickwork. It is packaged dry and must be mixed with water prior to use, very much like cement or plaster. 6. Baffle tiles are a specially shaped refractory made of silicon carbide for use in some boilers to form baffles on superheater screen tubes. These baffles direct the flow of combustion gases across the superheater to help maintain the temperature within design parameters. 7. When the refractory is installed and stacked, it must be held in place. Anchor bolts are used for preformed refractory. The anchor bolts are connected to the inner casing to support and retain the refractories in position. 8. Since the boiler expands and contracts with heating and cooling, expansion joints are built into the refractory to allow for the thermal expansion and contraction. Q. Since the boiler expands and contracts as it heats up and cools down, sliding feet are installed to allow the boiler to move easily. The feet are located below the boiler, usually under the front end of the sidewall header and water drum. There is a greased phosphor bronze friction plate on which these feet will move. The planned maintenance system (PMS) requires lubricating the sliding feet every month. Some newer ships have permalube sliding feet which never require lubrication. Failure of the sliding feet to move can cause cracks in the air casing and can cause header handhole plug leaks. Movement indicators are installed on the sliding feet which have to be checked prior to light off, during warm up, and after the boiler are on line to ensure positive movement of the sliding feet. Each time sliding feet are checked the results should be logged in the fireroom operating log. (Refer to figure 6)

SLIDING FEET CONFIGURATION

Page 11: BOILERdocshare02.docshare.tips/files/25397/253975236.pdf · 2017-01-24 · boiler at 120% with boiler steam stop valves closed (refer to Figure 3). These valves are discussed in detail

Figure 6 R. The boiler is enclosed by casings which provide an airtight boundary from the boiler furnace up through to the stack area. The inner casing encloses the boiler fireside area to the base of stack to provide an airtight lining between the combustion air space and furnace to contain the products of combustion within the boiler and support the refractory materials. The outer casing encloses the entire boiler from the bilge to the stack to provide double encasement so the boiler air pressure is not affected by the fireroom atmosphere. The combustion air flows through this space between the inner and outer casing and is directed to the air registers. The stack is located above the boiler economizer and extends to above the superstructure to carry boiler combustion products safely away from the ship. The inner stack or smoke pipe provides a path for combustion gases to the atmosphere, the outer stack supports the inner stack and provides a space to receive incoming combustion air to the boiler and protects personnel from the hot inner stack surfaces. S. The fireroom watch team must be able to monitor the exhaust gases to help maintain a clear smoke free stack. Smoke indicators and periscopes are installed to allow monitoringof the stack gases leaving the boiler. The smoke indicator is an electro-mechanical deviceand the periscope is an optical device. All ships have periscopes and many have electro-mechanical smoke indicators or stack gas analyzers. These devices are located above the economizer at the base of the stack so that combustion gases leaving the boiler must pass through its line of sight or the sensing element. From monitoring the stack gases, the combustion process can be adjusted for maximum efficiency or a casualty situation can be detected (Refer to Figure 7)

TYPICAL PERISCOPE CONFIGURATION

Page 12: BOILERdocshare02.docshare.tips/files/25397/253975236.pdf · 2017-01-24 · boiler at 120% with boiler steam stop valves closed (refer to Figure 3). These valves are discussed in detail

T. Maintaining proper boiler water level is one of the most critical aspects of boiler operation. To be able to monitor this critical parameter water level indicators are installed. There are two types, a direct reading gage glass mounted on the steam drum and a remote water level indicator. The gage glass gives a direct measurement of the steam drum water level. The remote water level indicator gives an inferential indication of the steam drum water level. 1. The direct reading gage glass may be isolated or removed for maintenance if necessary but, at least two remote water level indicators must be installed and working. (Refer to Figure 8).

REMOTE WATER LEVEL INDICATOR

Page 13: BOILERdocshare02.docshare.tips/files/25397/253975236.pdf · 2017-01-24 · boiler at 120% with boiler steam stop valves closed (refer to Figure 3). These valves are discussed in detail

Figure 8 2. There are usually two remote water level indicators in the fireroom for each boiler. They are located on the lower level and the BTOW/console station. There is also a remote indicator located at the throttle station for the engine served by that boiler. 3. There are high and low water alarms installed in the remote water level indicators. They are set to alarm when the steam drum water level reaches 7 inches above normal or 6 below normal inches on most steam ships. U. Because air casing fires sometimes occur in the boiler, a steam smothering system is installed between the inner and outer casings. This piping comes from the 150 psi desuperheated steam system and is perforated to allow the steam to fill the casing and smother the fire. The piping is located at the lower portion of the casing under the furnace floor and/or brickpan. Steam can be admitted to the furnance by filling the air casing and then opening the air registers. (Refer to figure 9).

STEAM SMOTHERING CONFIGURATION

Page 14: BOILERdocshare02.docshare.tips/files/25397/253975236.pdf · 2017-01-24 · boiler at 120% with boiler steam stop valves closed (refer to Figure 3). These valves are discussed in detail

Figure 9

V. Once the steam flowing through the superheater is what keeps it from overheating, there must be a means of providing a flow prior to any steam pressure forcing a flow. This means is called the superheater protection steam system. The inlet is connected to the steam drum steam outlet piping and outlet is connected to the desuperheater outlet piping. This arrangement provides steam flow through the superheater during light-off and securing. It is also the entry point for the steam used to provide a steam blanket lay-up. The steam bled off the boiler to provide the flow is routed to the auxiliary exhaust system. When the boiler is being secured, this system needs to be aligned to prevent over-pressurization of the boiler because it is still generating steam. This system is commonly called the superheater bleeder. (Refer to figure 10)

SUPERHEATER PROTECTION SYSTEM

Page 15: BOILERdocshare02.docshare.tips/files/25397/253975236.pdf · 2017-01-24 · boiler at 120% with boiler steam stop valves closed (refer to Figure 3). These valves are discussed in detail

Figure 10 W. Fuel oil burners are located on the boiler front and extend into the furnace to provide ameans of firing the boiler. Depending on boiler design two to six burners are installed in the boiler. (Refer to Figure 11).

BURNER ASSEMBLY

Page 16: BOILERdocshare02.docshare.tips/files/25397/253975236.pdf · 2017-01-24 · boiler at 120% with boiler steam stop valves closed (refer to Figure 3). These valves are discussed in detail

Figure 11 1. The burners deliver fuel and air to the boiler furnace in the proper mixture to obtain optimum combustion. The two main components of an oil burner are the atomizer assembly and the air register assembly. The atomizer divides the fuel oil into very fine particles, the air register admits combustion air to the furnace and promotes mixing of the air and the fuel oil spray. 2. The types of atomizers used on ships are straight mechanical, steam, and vented plunger, as described below. 3. In straight mechanical atomization, all the oil pumped to the atomizer is sprayed into the furnace. The firing rate of this type of burner is controlled by varying the supply fuel oil pressure and changing sprayer plate sizes. 4. In steam atomization, steam is used to help atomize the oil into minute particles and to project a cone shaped spray of atomized oil into the furnace. 5. The vented plunger type atomizer is designed to permit a wide range of operation using the straight mechanical pressure atomization principle without the need to change sprayer plate sizes or use steam atomization. It is found in 1200 psi boilers. X. Because the combustion gases leave ash or soot deposits on the tube surfaces which inhibit efficient heat transfer, the soot must be removed. Soot blowers use steam to blow soot off of the tube surfaces. In addition to acting as an insulator, this soot forms sulfuric acid when it becomes wet and eventually corrodes the tube metal. 1. Boilers have varying numbers of soot blowers but, there are two basic types, rotary and stationary. They use unreduced desuperheated steam as the motive force which is reduced in the element by an orifice to 300 psi for rotating units and approximately 150 psi for stationary units. Using relatively hot steam at a reduced pressure minimizes moisture in the steam which can lead to erosion or acid corrosion.

Page 17: BOILERdocshare02.docshare.tips/files/25397/253975236.pdf · 2017-01-24 · boiler at 120% with boiler steam stop valves closed (refer to Figure 3). These valves are discussed in detail

2. The rotary type of soot blower has multi-nozzle elements. The soot blower head steam valve is actuated by a cam when the element is rotated. The element can be turned by a crank, chain, or an air or electric motor. Steam is admitted from the head into an element which incorporates uniformly spaced nozzles/holes to evenly distribute steam along the area covered. (Refer to figure 12) ROTARY SOOT BLOWER

Figure 12

3. The stationary type of soot blower usually has one or two rows of nozzles directed to the area immediately near the drums of the boiler. Steam is admitted for a short duration by a manually or power actuated stop valve. 4. The soot blower element must be kept cool and clean during operation. To

Page 18: BOILERdocshare02.docshare.tips/files/25397/253975236.pdf · 2017-01-24 · boiler at 120% with boiler steam stop valves closed (refer to Figure 3). These valves are discussed in detail

accomplish this, a small amount of air is piped into the element through a small air line. This air is called scavenging air and comes from the combustion air that pressurizes the boiler air casing. This allows a small amount of air to enter the soot blower element to keep it cool and clean. There is a check valve installed in this line to prevent steam from entering the air casing during soot blower operation. 5. The operation of soot blowers is called "blowing tubes." Tubes are blown on the following minimum occasions: a. After leaving port b. Before entering port c. After making heavy smoke d. Once each week when steaming NOTE: EOSS requires tubes to be blown prior to securing a boiler, if possible. Y. Since the boiler water chemistry control systems, Chelant or Coordinated Phosphate, both settle sludge to help maintain water purity, there must exist a means to remove this sludge. The bottom blowdown system is used to remove sludge from the water drum and the lower headers. The surface blowdown system is used to remove suspended particles in the water and provide a means of changing out the water in the boiler to lower the conductivity and dissolved substances. Both systems share a common piping arrangement with an overboard guarding valve and overboard discharge valve. (Refer to figure 13)

SURFACE/BOTTOM BLOWDOWN PIPING

Figure 13

1. Surface blowdowns are conducted on a steaming boiler as needed to maintain boiler water within the proper chemical control limits. The Chelant system also uses an occasional scum blow to maintain limits. 2. A boiler is bottom blown only when it is secured. Never bottom blow a steaming

Page 19: BOILERdocshare02.docshare.tips/files/25397/253975236.pdf · 2017-01-24 · boiler at 120% with boiler steam stop valves closed (refer to Figure 3). These valves are discussed in detail

boiler since this could cause a loss of natural circulation and boiler damage. Boilers shall be secured and bottom blown every 360 steaming hours if the Chelant treatment system isinstalled or every 168 if the Coordinated Phosphate (COPHOS) system is in use. There are many conditions that require a boiler to be bottom blown. For a complete listing referto NSTM 221 or 220 volume II. B. Knowing the water/steam flow through the boiler is critical to understanding the interrelationships of the boiler components. A summary follows: 1. The flow begins when feedwater enters the economizer inlet header and flows through the economizer tubes to the outlet header picking up approximately 100-200° F of sensible heat to about 350°F. 2. Feedwater leaving the economizer enters the steam drum via the internal feed pipe. The feed pipe distributes the water evenly along the length of the steam drum. 3. Boiler water then flows over the baffle plates to the ends of the drum where the cooler more dense water flows down through the downcomers to the water drum and lower headers. 4. Water in the water drum and lower headers is distributed to the various generating tubes to replace the water being generated into steam. 5. As water rises through the tubes, it is exposed to the combustion gases through the tube walls increasing the water temp which decrease it's density, allowing it to continue the flow upward. 6. Continuing upward, a portion of the water changes to steam and enters the steam drum under the baffle plates. The water-steam mixture is guided to the primary separators which separate the excess water from the steam by centrifugal motion. Separated water falls back to the steam drum above the baffle plates. 7. Steam exits the primary separator and enters the secondary separators where the rapidchanges in direction of flow causes it to give up more moisture. Moisture removed drainsback to the steam drum above the baffle plates. 8. All accumulated steam is directed to the dry box. The quality of saturated steam leaving the steam drum is designed to be 99.75% moisture free. 9. Steam flows through the saturated steam line to the superheater inlet header. It makes four passes through the superheater increasing steam temperature 300-400° F to approximately 850° F and then exits through the outlet header. 10. Superheated steam leaves the outlet header and a portion is routed to the desuperheater inlet based upon system demand. All remaining steam goes through the main steam stop to the main steam system to provide superheated steam to the main engine turbines, ship's service turbine generators (SSTG), and on some ships, the main feed pumps (MFP). 11. The steam that passes through the desuperheater which is submerged in the water drum, gives up superheat to the surrounding water. Steam leaving the desuperheater passes through the auxiliary steam stop to provide steam to all auxiliary system demands.

Page 20: BOILERdocshare02.docshare.tips/files/25397/253975236.pdf · 2017-01-24 · boiler at 120% with boiler steam stop valves closed (refer to Figure 3). These valves are discussed in detail

12. A summary of the combustion gas flow follows: a. Combustion gases flow from the furnace through the screenwall tubes, superheater tubes, main generating bank, and economizer. The hot combustion gases then pass through the inner stack and finally exit the stack to the atmosphere. (Refer to figure 1)

Boiler Operations:

INTRODUCTION

Proper boiler operation is essential to allow the ship to operate effectively and efficiently. This can be accomplished by operating the boilers within parameters. The parameters and sensing points vary by boiler design.

REFERENCES

Page 21: BOILERdocshare02.docshare.tips/files/25397/253975236.pdf · 2017-01-24 · boiler at 120% with boiler steam stop valves closed (refer to Figure 3). These valves are discussed in detail

(a) Boilers NSTM Chapter 221 (b) Fireman NAVEDTRA 10520 series (c) Boiler Technician 3&2 NAVEDTRA 10535 series (d) Principles of Naval Engineering 10788 series (e) Boiler Operation and Maintenance Manual NAVSEA 0951-LP-022-6010 (f) Boilerwater/Feedwater Test and Treatment NSTM Chapter 220 V2

INFORMATION

With the boiler design in mind, certain objectives should include protection of the boiler's pressure parts against corrosion, overheating, and thermal stress. Proper operation reduces the chance of damage and ensures the production of steam at the desired temperature, pressure, and purity.

Normal steady-state operating parameters of a D-type boiler and their sensing points:

Steam drum pressure Setpoint psig ± 5 psig

Steam drum water level Normal ± 1"

Superheater outlet temperature (600 psig) 800-850°F

Economizer inlet 240-250°F

Economizer outlet 340-450°F

At a steady rate of steaming the boiler steam drum pressure should remain steady at set point ±5 psig. If steam pressure becomes excessive, safety valves will lift to reduce the pressure to a safe limit. If steam pressure is allowed to drop lower than 85% of operating pressure, natural circulation will be disrupted and possibly cause overheating of the boilertubes. When pressure has dropped this low, the forced-draft blowers (FDB) cannot supply enough combustion air to return the boiler to its set point. High or low pressures are usually caused by faulty automatic boiler controls (ABC) or improper acceleration or deceleration of the main engine throttle valve.

Steam drum water level is critical during boiler operation. Watchstanders monitor the boiler gage glass and remote water level indicators. The remote water level indicator alsoactivates an audible alarm when boiler water level is at +7" or -6" to warn watchstanders of the condition. The boiler shall be secured when these alarms sound. The water level should remain at normal level in the gage glass at a steady steaming state, with a tolerance of ±1". High water in the boiler is when the water level is out of sight (high) in the boiler gage glass. This is the most damaging condition to both personnel and equipment, as the water may carry over with the steam into the superheater and main steam piping. This can damage the superheater and turbines. Water can cause corrosion or chemical build-up on turbine blades and could cause destruction of the turbine and injury to personnel. Low boiler water level is when the water level is out of sight (low) inthe boiler gage glass. Without water in the boiler tubes, the tubes will quickly and ultimately rupture. Water level problems can be caused by faulty ABCs, a malfunctioningfeedwater control valve, main feed booster pump, or main feed pump.

Due to the nature of a ship's operations, the steam demand on a boiler changes frequently. These frequent demand changes affect the boiler water level. When steam demand is

Page 22: BOILERdocshare02.docshare.tips/files/25397/253975236.pdf · 2017-01-24 · boiler at 120% with boiler steam stop valves closed (refer to Figure 3). These valves are discussed in detail

increased, the water level temporarily increases. This increase is normally allowed to increase up to a +4" to +6", depending on the boiler design. The increase in demand will also decrease steam pressure. Steam pressure is allowed to deviate a maximum of 8% from the set-point pressure. The increase in steam flow through the superheater momentarily lowers the outlet temperature 10-20°F. As the boiler supplies more steam to the system, the main feed pump increases in speed to maintain feed pressure to the boiler at 150 psig above steam drum pressure. To accommodate the increase in demand, the fueloil pressure and combustion air flow also increase proportionally. All these actions happen simultaneously through the use of the ABC system.

When steam demand is decreased, the water level in the boiler shrinks, the water level temporarily drops. The water level is normally allowed to decrease to a -3" to -4", depending on the boiler design. The decrease in demand also increase steam pressure. Steam pressure is allowed to deviate a maximum of 3% from set point pressure. The decrease in steam flow through the superheater momentarily increases the outlet temperature 10-20° F. As the boiler is supplying less steam to the system, the main feed pump slows to accommodate the decreased feed water requirements of the boiler. To accommodate the decrease in demand, the fuel oil pressure and combustion air flow will also decrease proportionally. All these actions happen simultaneously through the use of the ABC system.

During normal operation, the economizer inlet temperature should be maintained between240-250°F. A low deaerating feed tank (DFT) outlet temperature will cause the economizer inlet temperature to be low. This causes the boiler to increase the firing rate to make up for the lower temperature. The steam flow from the boiler through the superheater remains the same. An increased firing rate and an unchanged steam flow cause the superheater temperature to increase proportionally. The opposite happens whenthe DFT outlet temperature is high. This causes the boiler to decrease the firing rate without a change in steam flow. This causes the superheater temperature to decrease proportionally.

Superheater outlet temperature normally should not exceed maximum except during transients. If the temperature were to remain excessive, the superheater will overheat and could suffer a ruptured boiler tube. Causes of a high superheater outlet temperature are:

Faulty temperature indicators High levels of excess air Improperly installed furnace gas baffles Incorrect fuel oil burner settings and alignment Improper automatic combustion control adjustments Damaged fuel oil burner sprayer plates Leaking fuel oil atomizers Incorrect burner sequence and mixed sprayer plates Leaky desuperheater Low feedwater temperature Dirty economizer firesides Low boiler steam pressure Gas side or fireside restrictions Low steam flow

Page 23: BOILERdocshare02.docshare.tips/files/25397/253975236.pdf · 2017-01-24 · boiler at 120% with boiler steam stop valves closed (refer to Figure 3). These valves are discussed in detail

A low superheater temperature will cause the boiler to operate at an increased rate to compensate for the lower temperatures, thereby increasing fuel consumption and reducingefficiency. Causes of a low superheater outlet temperature are as follows:

Drum pressure too high Feedwater temperature too high Wrong burner combination Levels of excess air too low or much too high Excess moisture carry-over Superheater tubes fouled either on the steam side or firesides Improper gas baffles and improper bypass areas

The boiler is the "holding tank" for all impurities in the boiler water. These impurities enter the boiler from the feed system or result from the chemical treatment of the boiler water. Since the boiler may be thought of as an efficient evaporator, almost every impurity that enters, will remain in the boiler unless means are provided to rid the boiler of it. These impurities either form scum, which floats on the surface of the water in the steam drum, or sludge, which settles in the lower headers and water drum. To remove these impurities we use the blowdown system. The system is aligned in accordance with Engineering Operational Sequencing System (EOSS) from the hull or skin of the ship to the boiler. The securing is in the reverse order, from the boiler to the skin of the ship.

Surface blowdown provides the normal control of boiler water conductivity, chemical overtreatment, and nondetergent lubricating oil. Surface blowdown shall be conducted ona steaming boiler as necessary in accordance with NSTM 220 V2 as discussed in lesson 62B-203. The following procedures produce a 10% surface blow.

The EOOW must obtain permission to blowdown the boiler from the OOD (u/w) or CDO(inport). Align the blowdown system by first opening the overboard discharge valve and then the overboard guarding valve. By manual or remote manual control raise the boiler water level to three inches above the surface blow take-off pipe in the steam drum. This amount is standard; however, boiler design varies somewhat in the location of the surface blow take-off pipe. Maintain the water level for 4-5 minutes, then open the surface blow valve and monitor boiler water level. Close the surface blow valve quickly when water level has dropped three inches, then repeat these steps a second time, for a total of two blowdowns. After completing the surface blow, return water level to the normal operating level. Close the overboard guarding and overboard valves. Open the drain to the bilge carefully and allow the system to drain off residual water. Flow should stop to indicate the tight seating of the surface blow valve. Some systems have overboard guarding and overboard valves that require a second tightening of these valves after 15 minutes to ensure a tight seal.

A bottom blowdown removes sludge from the lower circuits of the boiler. The boiler mustbe secured and allowed to stand for a minimum of one hour prior to conducting a bottom blow. A successful bottom blow results in a reduction of the water level in the steam drum. Steam drum water level must be maintained in sight in the boiler gage glass. If deaerated feedwater is not available, discontinue the blowdown and record which valves were not blown in the boiler water chemistry log. Procedures for bottom blowdown are asfollows:

The EOOW will obtain permission to conduct blowdown from the OOD or CDO. Raise the steam drum water level to +6 inches using the main feed system from an on-line

Page 24: BOILERdocshare02.docshare.tips/files/25397/253975236.pdf · 2017-01-24 · boiler at 120% with boiler steam stop valves closed (refer to Figure 3). These valves are discussed in detail

boiler, or using residual steam from the boiler being blown to operate the main feed pump. Align the blowdown system in the same manner as for a surface blow, opening theoverboard and overboard guarding valves. Starting with the water drum valve quickly and fully open the valve until steam drum water level has dropped two inches, then quickly close the valve. Repeat this procedure at each header valve, but allow the water level to drop only 1 to 1½ inches of water, then quickly close the header valve. After the blowdown is complete, secure the system in the same way as for a surface blowdown and check the drain for proper sealing of the bottom blow valves. Bottom blowing a steamingboiler can disrupt natural circulation and cause overheating and ruptured tubes and shall not be done. The 100 psig requirement on the secured boiler ensures there is sufficient pressure to overcome seawater pressure on the hull to perform a proper blowdown.

Soot blowing boiler tubes is necessary to remove the accumulation of fireside deposits from the tubes. Soot is an insulator and must be removed to ensure efficient operation and proper heat transfer. Procedures for soot blowing are as follows:

Permission must be obtained from the Officer Of the Deck (OOD) before starting to blowsoot from the boiler. The OOD puts the ship on the best possible course so that soot from the stacks will clear the topside decks and equipment. While conducting soot blowing on a boiler that is supplying steam to the main engine, consideration must be taken that speedand maneuverability will be limited during this operation. Soot blowing shall begin whenthe boiler is at a firing rate of 50 percent or greater. This is so that the action of blowing steam into the firesides will not affect the stability of the flame on the burners. The burnerman should monitor flame stability carefully during soot blower operation. Align the soot blowing system in accordance to EOSS and ensure that the system is free of any condensate before commencing. As a precaution station a watchstander at the soot blow steam root valve for the entire evolution in case of system failure. Raise boiler air casing pressure two to three inches so that dislodged soot will be carried clear of the boiler and out the stack. To ensure maximum efficiency of the soot blowing operation, blow the economizer first. This will clear the economizer area of any soot that has collected since the last blowing operation. After this follow the sequence of blowing all the soot blowers,from the generating bank and upward in accordance with EOSS. The economizer soot blowers shall be blown again at the end of the operation. All soot blowers should be labeled in accordance with the manufacturer's technical manual for proper identification. The capacity of any boiler is limited by three factors that have to do both with the design of the boiler and with its operation. These limitations are called "end points" and there descriptions are as follows:

End point for combustion: The process of burning fuel oil in a boiler furnace involves forcing the oil into the furnace through atomizers which breaks up the oil into fog-like spray, and forcing air into the furnace in such a way that it mixes thoroughly with the oil spray. The amount of fuel oil that can be burned is limited primarily by the actual capacity of the equipment that supplies the fuel (including the capacity of the sprayer plates) by the amount of air that can be forced into the furnace, and by the ability of the burner apparatus to mix this air with the fuel. The volume and shape of the furnace are also limiting factors. The end point for combustion for a boiler is reached when the capacity of the sprayer plates is reached, at the designed oil pressure for the system, or when the maximum amount of air that can be forced into the furnace is insufficient for complete combustion of the fuel. If the end point for combustion is actually reached because of insufficient air, the smoke in the uptakes will be black because it will contain particles of unburned fuel. This condition, however, is rare since the end point of combustion is artificially limited by sprayer plate capacity when fuel oil is supplied to the

Page 25: BOILERdocshare02.docshare.tips/files/25397/253975236.pdf · 2017-01-24 · boiler at 120% with boiler steam stop valves closed (refer to Figure 3). These valves are discussed in detail

burner manifold at designed operating pressure. This artificial limitation upon combustion in the boiler furnace is the factor that would cause the end point of combustion to occur before either of the other two end points.

End point for moisture carry over: The rate of steam generation should never be increased to the point at which an excessive amount of moisture is carried over in the steam. In general, naval specifications limit the allowable moisture content of steam leaving the saturated steam outlet to ¼ to 1 percent. Excessive carryover can be extremely damaging to piping, valves, and turbines, as well as to the superheater of the boiler. It is not only the moisture itself that is damaging but also the insoluble matter that may be carried in the moisture. This insoluble matter can form scale on superheater tubes, turbine blades, piping and fittings; in some cases, it may be sufficient to cause damage to rotating parts. Because modern naval boilers are designed for high evaporation rates, steam separators and various baffle arrangements are used in the steam drum to separate moisture from the steam.

End point for water circulation: In natural circulation boilers, circulation is dependent upon the difference between the density of the ascending mixture of hot water and steam and the density of the descending body of relatively cool water. As the firing rate is increased, the amount of heat transferred to the tubes increases with a corresponding increase in the upward flow of the steam/water mix. The number of tubes devoted to the downward flow of water remains constant; therefore, a point would eventually be reachedwhen the downward flow would be insufficient to supply the upward flow of steam/water mix, and the tubes could overheat and rupture. This condition would determine the end point for water circulation. The use of downcomers ensures that the end point for water circulation will not be reached merely because the firing rate is increased.

BASIC STEAM CYCLE/BOILERS

Information Sheet Number 60B-102

INTRODUCTION

Steam is the working substance used for the propulsion of many surface ships, including nuclear and conventionally powered steam ships. Central to understanding the operation of steam propulsion is the basic steam cycle, a process in which we generate steam in a boiler, expand the steam through a turbine to extract work, condense the steam into water, and finally feed the water back to the boiler. This is accomplished by a series of heat transfers and work exchanges throughout system..

We will introduce the basics of naval propulsion and auxiliary boilers, review the basic steam cycle, and examine the major components of this cycle in detail, focusing on required temperatures and pressures and where heat and work are added and removed.

REFERENCES

Page 26: BOILERdocshare02.docshare.tips/files/25397/253975236.pdf · 2017-01-24 · boiler at 120% with boiler steam stop valves closed (refer to Figure 3). These valves are discussed in detail

(a) Elements of Applied Thermodynamics, Robert M. Johnson, et al.

(b) Principles of Naval Engineering NAVPERS 10788 series

INFORMATION

A. Boilers- boilers are used on almost all naval vessels, either to provide steam for propulsion turbines or to provide steam used in hotel services such as space heaters, hot water heaters, sculleries, laundry, etc. There are many different boilers used in the Navy. They can be classified in several ways.

1. Boilers can be classified according to the location of combustion and water sections.

a. Water-tube boilers are boilers in which the water is contained in generating tubes and hot combustion gases flow around the tubes to heat them. Propulsion boilers are of this type.

b. Fire-tube boilers channel combustion gases through tubes which are surrounded by water. Some auxiliary boilers are of this type.

Boilers can also be classified by the way they circulate water through the boiler. Natural circulation boilers use convection to circulate water in the boiler (figure 1). Relatively cool water enters the steam drum from the economizer and, because of its higher density, circulates down through large diameter downcomers to the water drum and lower headers. From there, thewater rises in generating tubes and begins to boil into steam. No pump is required for this process. The difference in fluid densities moves the working fluid.

c. Natural circulation may either be free or accelerated depending upon the steepness of the angle of inclination of the generating tubes and the location of the tubes carrying the cooler water downward. Accelerated natural circulation boilers have very steeply inclined generating tubes.

d. Forced circulation is a boiler configuration in which a pump is used to circulate water through the boiler. Forced circulation is primarily used for auxiliary boilers and land-based power plants where there are few variations in demand.

Page 27: BOILERdocshare02.docshare.tips/files/25397/253975236.pdf · 2017-01-24 · boiler at 120% with boiler steam stop valves closed (refer to Figure 3). These valves are discussed in detail

Figure 1: Principle of Natural Circulation

2. Boilers are most commonly classified according to intended service.Propulsion boilers are boilers which provide steam for propulsionturbines, and propel the ship through the water by way of reduction gears,shafting, and propeller. There are two basic configurations for propulsionboilers used today on naval vessels, the 1200 psig D-type and the 600 psigD-type. The 1200 psig and 600 psig refer to the approximate pressures atwhich the boilers operate. D-type simply means that the parts of the boilerpressure vessel together form a shape similar to the letter "D."

a. On most ships the propulsion boilers also provide steam atreduced pressure for hotel services mentioned above. On shipswhich are not propelled by steam, gas turbine and diesel ships, forexample, some type of boiler is still used to provide hotel servicesteam. There are two such boiler types:

1. Auxiliary boilers are usually smaller, lower pressureversions of propulsion boilers, in which fossil fuels areburned to heat the boiler tubes. The LSD-41 and AOE-6class ships are examples of ships which use auxiliaryboilers. These boilers consist essentially of a steam drumand a water drum which are connected by a bank ofgenerating tubes. These boilers are not equipped withsuperheaters, desuperheaters or economizers. Most ofthese boilers are not equipped with downcomers. Naturalcirculation takes place between the water drum and thesteam drum via the generating tubes and the screen tubes.The rear most generating tubes act as downcomers tosupply water to the remaining generating tubes and water

Page 28: BOILERdocshare02.docshare.tips/files/25397/253975236.pdf · 2017-01-24 · boiler at 120% with boiler steam stop valves closed (refer to Figure 3). These valves are discussed in detail

drum. Operation of these boilers varies widely, specificoperating manuals from the manufacturer must be used.(Figure 2)

Figure 2: Auxiliary Boiler

2. Waste heat boilers use heat that would otherwise bewasted by exhausting into the atmosphere to heat waterand make steam. For example, DD 963, DDG 993, andCG 47 class ships use exhausted combustion gases fromgas turbine generators to provide a heat source for wasteheat boilers. Steam for ship's services is generated byforced recirculation water tube type boilers. Recirculationof the boiler water is provided by a high head recirculatingpump which delivers a minimum of 500 percent excesswater under maximum evaporation demand. The boilertubes are finned and arranged in a coiled bundleconfiguration. Exhaust gas enters the bottom of the boilerand is discharged out the side of the casing. (Figure 3)

Page 29: BOILERdocshare02.docshare.tips/files/25397/253975236.pdf · 2017-01-24 · boiler at 120% with boiler steam stop valves closed (refer to Figure 3). These valves are discussed in detail

Figure 3: Waste Heat Boiler

3. There are limits to how much steam a boiler can produce. If excessivedemand for steam is placed on a boiler, the amount of fuel or air whichcan be supplied to the boiler may be physically limited. This is the endpoint of combustion and it will result in improper combustion in the boilerfurnace. Beyond this point, increased steam demand can actually causeliquid water to leave the boiler along with steam. This is the end point ofmoisture carryover and it is destructive to steam pipes, turbines, and otherequipment. Eventually, excessive steam demand can even cause adisruption of the natural circulation process discussed previously. This isthe end point of natural circulation.

B. The basic steam cycle is a four phased closed, heated cycle. This means that thefluid in the system is reused and heat must be added to the cycle. The heat isadded in the boiler firebox or furnace where the chemical energy of fuel isconverted to the thermal energy of combustion gases and water is boiled togenerate steam. This steam is expanded in the turbines, converting the thermalenergy of the steam into mechanical energy of the engines and other turbinedriven machinery such as turbine generators and main feed pumps. This steam isexhausted to a condenser which cools the steam and turns it to a fluid which canbe pumped through the system again. This condensed steam, or condensate, isdeaerated and pre-heated to remove oxygen and stored till needed. When needed,the water, now called feedwater, is raised to the proper pressure so that it can befed into the cycle again. The basic steam cycle is shown in Figure 4. Understand

Page 30: BOILERdocshare02.docshare.tips/files/25397/253975236.pdf · 2017-01-24 · boiler at 120% with boiler steam stop valves closed (refer to Figure 3). These valves are discussed in detail

that the pressures and temperatures in the following text and in Figure 4 arerepresentative of normal parameters in a generic 600 psig steam cycle. Actualparameters vary from specific ship designs and steam plant operating conditionsor configurations. Use the given parameters in a comparative manner to gain anunderstanding of system design and operation.

1. Generation Phase. To generate steam, it is necessary to heat water to itsboiling point by adding a sufficient amount of heat to change the boilingwater into steam. The heat required to change boiling water into steam, atany given temperature of the boiling water, is called the latent heat ofvaporization. When steam condenses back to water and an equal amountof heat is given off, it is called the latent heat of condensation. Theamount of heat required to convert boiling water to steam or the amountof heat given off when steam is condensed back to water at its boilingtemperature varies with the pressure under which the process takes place.

a. Feedwater enters the boiler steam drum through a perforatedinternal feed pipe. The feed pipe ensures the incoming feed water(now called boiler water once inside the boiler) is evenlydistributed throughout the length of the steam drum. The boilerwater then travels down the downcomers between the air casingsto the water drum. As the water travels up the generating tubes,the water is heated to its boiling point by the radiant heat from theboiler's furnace. The steam/water mixture reenters the steam drumat 490F. The water that did not turn to steam repeats the process.The steam is directed to moisture separators in the steam drum toremove any entrained water. The saturated steam is then piped outof the steam drum to the superheater.

b. In order to drive a turbine more efficiently and economically, weneed to raise the steam's energy level. We accomplish this bysuperheating the saturated steam in the superheater. Thesuperheater is usually a four pass heat exchanger closer to theflames of combustion than the generating tubes. As the steamtravels through the superheater, its temperature is raised to 800-850F. Steam exiting the superheater is at 600 psig and referred toas "superheated", or more commonly, "main" steam.

c. Some of the superheated steam will not be used for main steamapplications and is directed to a heat exchanger called thedesuperheater. Depending upon boiler design, the desuperheateris located either in the water drum or steam drum. A portion of the800-850F superheated steam travels through the desuperheaterand gives up some (not all) of its superheat to the water in thesteam or water drum. Steam exits the desuperheater atapproximately 650F. Although this steam is referred to as"auxiliary" or "600 pound desuperheated" steam, it is stillsuperheated. This steam will be used in smaller, auxiliary turbines(hence the name auxiliary steam), or reduced in pressure for otheruses such as 150 psig steam for air ejectors and steam atomization.

2. Expansion Phase. The expansion phase of the basic steam cycle is wheresteam is expanded in turbines to convert the thermal energy of steam tothe mechanical energy of rotation in the turbines. In the main engineturbines, the mechanical energy is used to drive the ship's propulsion shaftand propeller. In the ship's service turbine generators (SSTGs), thismechanical energy of rotation is further converted to electrical energy in

Page 31: BOILERdocshare02.docshare.tips/files/25397/253975236.pdf · 2017-01-24 · boiler at 120% with boiler steam stop valves closed (refer to Figure 3). These valves are discussed in detail

the generator. The main steam system is the piping system which leads thesteam from the boiler to the turbines which use main steam. These arealways the main engines and SSTGs and sometimes the main feed pumps(MFPs).

a. After leaving the superheater, the majority of the main steam ispiped to the main engine's high and low pressure turbines (HP andLP turbines). The remaining main steam is used in Ship's ServiceTurbine Generators (SSTG) and in some designs by the MainFeed Pumps (MFP). In the turbines, the thermal energy (increasedby superheating) is converted to mechanical energy which rotatesthe turbines. As the steam "expands" through the turbines (i.e. itsthermal energy is converted to mechanical energy), the steam'spressure and temperature are greatly reduced.

b. After the steam passes through the low pressure turbine (LPturbine) it enters the main condenser. Steam passing through anSSTG enters the auxiliary condenser. Depending upon the amountof steam passing through the HP and LP turbines (a function ofengine speed), the steam exits the LP turbine at about 100F. Inthe condenser (a heat exchanger), sea water passes through tubesand the steam is directed across the tubes. As the steam comes incontact with the cool tubes, the steam gives up heat (latent heat ofcondensation) to the sea water and condenses into water calledcondensate.

3. Condensation Phase.a. When steam changes phase from vapor to water in the main and

auxiliary condensers, that water is called condensate. The mainand auxiliary condensers operate under a vacuum in order to lowerthe steam's condensation temperature. The greater the temperaturedifference between the heat source (boiler) and heat sink(condenser), the greater the system's efficiency. Simply put, thegreater the vacuum in the condenser, the more efficient thesystem. As the steam condenses and leaves or exhausts from thelow pressure turbine, it becomes part of the condensate system.The condensate system is that part of the steam cycle in which thesteam condenses to water and is pumped from the main condensertoward the boiler. Before it can be used in the boiler, it must beconverted to feedwater which occurs in the feed phase. The threebasic components of the condensate system, in sequence, are themain condenser (including the hotwell), the main condensatepumps (usually two) and the main air ejector condenser.

b. The main condenser is a cross flow shell and tube type heatexchanger which receives the steam from the low pressure turbineand condenses it into water. The main condensate pump is acentrifugal pump which takes suction from the main condenserhotwell and delivers the condensate into the deaerating feed tank(DFT). The flow rate of this pump is controlled by the designfeature submergence control. This means that the water level inthe hotwell controls the pump flow rate and discharge pressure byvirtue of the location of the pump in relation to the hotwell and thepiping size.

c. Condenser vacuum is measured in inches of mercury where0"HgVac is atmospheric pressure (no vacuum) and 30"HgVac is a

Page 32: BOILERdocshare02.docshare.tips/files/25397/253975236.pdf · 2017-01-24 · boiler at 120% with boiler steam stop valves closed (refer to Figure 3). These valves are discussed in detail

perfect vacuum (Hg is the chemical abbreviation for mercury andVac = vacuum). A condenser's vacuum is derived from steamcondensing. When a large volume of steam is rapidly condensedinto a small volume of water, the space formally occupied by thesteam is now empty or a vacuum. Unfortunately, mixed with thesteam is some air and other non-condensable gases which remainafter the steam condenses into water. These gases must beremoved from the condenser to preserve the vacuum. For this task,air ejectors take a suction on the condenser to remove the air andnon-condensable gases. The main air ejector takes a suction onthe main condenser and there is an auxiliary air ejector for eachSSTG. In either condenser, a vacuum of 28-29"HgVac (0.5-1.0psia) is the norm. The outlet temperature of the main and auxiliaryair ejector condensers is maintained at 140-165F by athermostatic recirculation valve (TRV) located at the air ejectorcondensate discharge. During low bells (ship speeds), littlecondensate is produced and the flow rate of condensate passingthrough the air ejector condensers is low. The condensatetemperature at the outlet increases because it stays inside thecondenser longer absorbing more heat. When above 140F, theTRV opens, sending some condensate back to the condenserthereby effectively increasing the condensate's flow rate throughthe air ejector condenser which reduces the condensate dischargetemperature. At higher bells, the condensate flow rate increases(more steam condensed = more condensate), and the TRVrecirculates little or no condensate. Although steam condenses inthe main condenser around 100F, condensate temperature in thehot well may vary between 100-130F due to mixing with the hotcondensate recirculated by the air ejector TRV.

d. The condensate collects in a low point in the condenser called thehotwell. From here, the condensate flows to one or both maincondensate pumps (MCP) from the main condenser and eachauxiliary condenser's auxiliary condensate pump. These pumpsdischarge the condensate at 20-25 psig to provide enough pressurehead to flow through the condensate system and overcome the 15psig shell pressure in the deaerating feed tank (DFT).

e. After leaving the main and auxiliary condensate pumps, thecondensate enters the DFT .The DFT divides the condensate andfeed phases. Its three basic functions are to deaerate thecondensate by freeing it of entrained oxygen and air, preheatcondensate and store feedwater to accommodate changes insystem demand. As the condensate enters the DFT, it is sprayedinto the upper dome of the tank by spring-loaded spray nozzles.The condensate is heated to preheat the water before it enters theboiler, and to deaerate the water. The DFT is maintained at 15 psigwhich raises water's saturation point to approximately 250F. Heatmakes it easier for the oxygen and gases in the condensate tocome out of solution. This concept is called "inverse solubility"which means that the hotter a fluid becomes, the easier it is fordissolved gases to come out of solution. Here, the condensate mistis heated by auxiliary exhaust (exhaust steam from turbines whichdo not have condensers) and high pressure drains (steam). The air

Page 33: BOILERdocshare02.docshare.tips/files/25397/253975236.pdf · 2017-01-24 · boiler at 120% with boiler steam stop valves closed (refer to Figure 3). These valves are discussed in detail

rises where it is evacuated from the upper portion of the DFT andoxygen-free condensate falls to the bottom of the DFT.

4. Feed Phase. The condensate that is collected in the storage section of theDFT is now called feedwater and becomes a supply for the steam cycle. Italso provides a positive suction head for the main feed booster pumps(MFBPs) or the main feed pumps (MFPs), as applicable.

a. The feedwater in the bottom portion of the DFT is piped to themain feed booster pumps (MFBP). These pumps take a suction onthe DFT and raise the feedwater's static (or gravity) head pressurefrom 15-25 psig to 35-50 psig to ensure a positive suction head forthe main feed pump (MFP). Since the MFP is a centrifugal pump,it needs a positive suction head to ensure adequate flow to cool thepump. The MFBPs provide this positive suction head for the MFPpreventing cavitation and flashing in the MFP suction. Some shipsdo not have MFBPs because the DFT is physically located asignificant distance above the MFPs. Due to this height difference,there is sufficient static head pressure to ensure a positive suctionhead for the MFPs.

b. The MFPs operate at variable speeds to maintain a constant feedsystem pressure to the boiler. The MFP discharges feedwater intothe main feed piping system at 150-200 psi greater than the boileroperating pressure. For example, the discharge pressure of theMFP, discharging to a boiler operating at 600-650 psig, willnormally be 750-850 psig. This discharge pressure is maintainedthroughout the main feed piping system, however, the volume ofwater discharged to the boiler is controlled by the feedwatercontrol valve which opens or closes as needed to maintain properwater level in the boiler. The MFPs are protected fromoverheating at very low steaming rates by recirculating somedischarge back to the DFT or the pump suction.

c. After the feedwater leaves the MFP, it passes through a heatexchanger located in the boiler exhaust stack called theeconomizer. The economizer is located in the flow of hot exhaustgases exiting the boiler and uses the hot gases to transferadditional heat to the feedwater before it enters the steam drum.By using the otherwise wasted heat in the exhaust gases, less fuelis required (economy) to raise the water's temperature to theboiling point. Feedwater enters the economizer from the feedsystem at approximately 246-249F and at 750-800 psig.Depending upon the boiler's firing rate, the economizer transfersapproximately 100-200F from the exhaust gases to the feedwaterso that the feedwater enters the boiler around 350-450F. Becausethe water was preheated throughout the condensation phase, theboiler need only provide enough energy to raise the water'stemperature about 40-140F to form steam.

d. Although the basic steam cycle is a closed cycle, it is an imperfectsystem and there are various feedwater losses which must bereplaced. Every attempt is made to recover the working fluidthrough such means as collecting the condensed steam in pipingsystems (called "drains") into a central location and pumping itback to the system. This central location is known as thefreshwater drain collecting tank (FWDCT). Even despite all

Page 34: BOILERdocshare02.docshare.tips/files/25397/253975236.pdf · 2017-01-24 · boiler at 120% with boiler steam stop valves closed (refer to Figure 3). These valves are discussed in detail

efforts to recover the working fluid, losses exist through leaks, etc.There also are unrecoverable losses designed into ships such assteam atomization of fuel oil burners and surface and bottomblows from boilers. These losses are made up for by adding morefeedwater to the cycle through the condensers. This make-up feed(MUF) is simply feed quality water which is stored in tanks andintroduced into the cycle as needed. The DFT water leveldetermines the amount of MUF needed by the system.

5. Steam plant configurations vary greatly in complexity, from destroyertenders with two boilers and one main engine to aircraft carriers with fourmain machinery rooms, eight boilers, and four main engines.

a. In ships with multiple propulsion plants, like aircraft carriers andamphibious ships, steam can be produced by one boiler andaligned to one main engine and SSTG(s) in one space, andanother boiler in another space can feed a different main engineand SSTG(s) in that space. This is called split plant operation. Forships with more than one propulsion plant, this is the normalalignment. It means that a boiler casualty only affects half of theship's mobility and auxiliary equipment.

b. In these ships with multiple plants, the boilers in one space can bealigned to provide steam to all operating equipment in both plants.This is called cross connected operation. It allows the use of oneboiler to steam two plants, but likewise means that a casualty toone boiler can affect all operating equipment.

Page 35: BOILERdocshare02.docshare.tips/files/25397/253975236.pdf · 2017-01-24 · boiler at 120% with boiler steam stop valves closed (refer to Figure 3). These valves are discussed in detail

Figure 4: Basic Steam Cycle

Page 36: BOILERdocshare02.docshare.tips/files/25397/253975236.pdf · 2017-01-24 · boiler at 120% with boiler steam stop valves closed (refer to Figure 3). These valves are discussed in detail

Cochran donkey boiler

The boiler has a dome-shaped furnace top that forms the bottom of the boiler itself. It has a neck on the front through which the boiler is fired and there is another on the rear part of the top that leads to a higher located combustion chamber. The combustion chambers backside is covered with brickwork and from its front-side ahorizontal bank of flue-tubes leads to the smoke box on the front side of the boiler.

The Cochran donkey boiler, or auxiliary boiler, was used in harbor when the main boilers were not needed for the propulsion of the ship and consequently the steam demand was low.

Cochran Marine Thermax boiler

A modern version

Page 37: BOILERdocshare02.docshare.tips/files/25397/253975236.pdf · 2017-01-24 · boiler at 120% with boiler steam stop valves closed (refer to Figure 3). These valves are discussed in detail
Page 38: BOILERdocshare02.docshare.tips/files/25397/253975236.pdf · 2017-01-24 · boiler at 120% with boiler steam stop valves closed (refer to Figure 3). These valves are discussed in detail

Firing boiler burner

Steam drum containing tube ends

Interior of water tube boiler drum

D-type water tube boilers fit in very well in the engine room space

Steam Boiler

Steam boilers are used either as main machinery for propulsion, as in Steam Ships, or as auxiliary machinery in Motor Ships.

Because of this difference, the size and pressures of the steam boilers in Steam Ships will be very much larger than that in Motor Ships. The dryness of the steam produced will also be different.

Basically, the boiler is a huge pressurized kettle, using fire to heat water to a boil and extracting the steam. The steam is used to channel heat energy from the fire to power machines,or to heat remotely located areas.

All the steamships use water tube boilers because of the higher pressures, but many motorships use fire tube boilers for lower pressures.

An exception is the boilers installed in oil tankers. These are often water tube boilers because of the higher demand for steam on these ships.

Care must be taken to condition the water in the boiler to prevent scaling, and corrosion, which can weaken the pressure vessel. With the use of heavy oil for fuel, it is also very important to ensure that the surfaces exposed to the fire are free of soot deposits and sulfur corrosion.

The burners usually require the most maintenance, as this is the place where the heat from the fire can carbonize the oil to form deposits.

The steam boiler is part of a closed loop steam system, whereby, after the energy of the steam is used up and it becomes water again, the latter is collected and returned back to the boiler for heating up again to steam.

Any leakages in the system will have to be replenished with fresh water.

Water tube boiler with two drums

Page 39: BOILERdocshare02.docshare.tips/files/25397/253975236.pdf · 2017-01-24 · boiler at 120% with boiler steam stop valves closed (refer to Figure 3). These valves are discussed in detail
Page 40: BOILERdocshare02.docshare.tips/files/25397/253975236.pdf · 2017-01-24 · boiler at 120% with boiler steam stop valves closed (refer to Figure 3). These valves are discussed in detail

A. Smoke uptakeB. Economizer

A heat exchanger that transfers heat from Boiler Flue Gases to Boiler Feedwater. C. SteamOutlet

Saturated steam from the SteamDrum to the Superheater D. Cyclone

A device inside the drum that is used to prevent water and solids from passing over with the steamoutlet.

E. Stay tubefor superheater

F. Staysfor superheater tubes

G. Superheated steam outletH. Superheater

A bank of tubes, in the exhaust gas duct after the boiler, used to heat the steam above the saturation temperature.

I. Superheater HeadersDistribution and collecting boxes for the superheater tubes.

J. WaterDrumK. BurnerL. Waterwall Header

Distribution box for waterwall and downcomers. M. FotingN. Waterwall

Tubes welded together to form a wall. O. Waterwall Header

Distribution box for waterwall and downcomers. P. Back side waterwallQ. Boiler hoodR. Waterwall Header

Collecting box for waterwall and risers. S. Riser

The water-steam emulsion rises in these tubes toward the steamdrum. T. Downcomer

A tube through which water flows downward. These tubes are normally not heated, and the boiler water flows through them to supply the generating tubes.

U. SteamDrumSeparates the steam from the water.

V. Economizer HeaderDistribution box for the economizer tubes.

Page 41: BOILERdocshare02.docshare.tips/files/25397/253975236.pdf · 2017-01-24 · boiler at 120% with boiler steam stop valves closed (refer to Figure 3). These valves are discussed in detail

Belleville water tube steam boiler

The feedwater was fed into the to the feed water collector, at the lower end of the tubes, by means of an automatic feedwater controller. The heating surface in the boiler consists of a set of continuous tubes running to-and-fro over the furnace. The steam generated in the tubes passes upwards into the steam collector, carrying muchwater with it, but the water is separated by baffle plates in the steam collector drum. The carried over water returns to the water collector through vertical pipes, down-comers, at the ends of the steam collector. The water level height during full steam operation was about the middle of the water tube bank.The boiler's steam outlet was always provided with a pressure reducing valve that dried the steamsince all remaining water evaporated at the lower pressure.Belleville boilers worked quite well at pressures between 12 and 16 bar, but false water level readings was a huge problem.Later boilers always had an economizer on the top.

Eckrohr Steam Boilers

Page 42: BOILERdocshare02.docshare.tips/files/25397/253975236.pdf · 2017-01-24 · boiler at 120% with boiler steam stop valves closed (refer to Figure 3). These valves are discussed in detail

Eckrohr-Boiler (Corner Tube Boiler) is a boiler for all kinds of fuel. Originally it got its name because it has downcomers in the four corners. It is a natural water circulation single drum boiler and it needs no circulation pump.Downcomers, headers and waterwalls are welded together to a gas-tight tube cage.The Eck-rohr-Boiler is self-supporting and needs no supporting structure. It stands on its own downcomers.

Due to the cage structure with downcomers, headers and overhead pipes the Eckrohr-Boiler is earthquake

safe (more than 550 boilers installed in Japan, many of them for municipal waste).

Page 43: BOILERdocshare02.docshare.tips/files/25397/253975236.pdf · 2017-01-24 · boiler at 120% with boiler steam stop valves closed (refer to Figure 3). These valves are discussed in detail

The new Eckrohr marinesteam boiler

design

This ERK boiler is designed to install on a tanker, which is used as utilities providing station for an offshore platform.

Eckrohr-Boilers are available asauxiliary boilers operating on oil or waste heat from the dieselengine. The weight of Eckrohr marine boilers is significantly low. The support structure on the ship is simple.The Eckrohr-Boiler configuration is particularly suited to marine duty as the water circulation is tolerant of high roll angles and will maintain safe water circulation at high inclination angles. Morethan 600 Eckrohr marine steam

boilers have been built.

Page 44: BOILERdocshare02.docshare.tips/files/25397/253975236.pdf · 2017-01-24 · boiler at 120% with boiler steam stop valves closed (refer to Figure 3). These valves are discussed in detail

Eckrohr Boilers water and steam flowdiagram

1. unheated return tubes 2. header 3. mixture tubes 4. riser tubes (evaporator) 5. overflow tubes 6. unheated steam drum 7. unheated downcomers

The water-steam mixture flows upwards through the riser tubes (4). In the upper mixture tube (3) steam is already separated from water and a part of the water flows through unheated return tubes (1) to the header

(2). The separated steam flows through the overflow tube (5) to the steam space of the drum (6). The remaining mixture runs through mixture tube (3) into the drum. The final separation of water and steam takes place in the drum, the water flows through the downcomers (7) to the headers (2).

Exhaust gas boiler with extended heating surface

Page 45: BOILERdocshare02.docshare.tips/files/25397/253975236.pdf · 2017-01-24 · boiler at 120% with boiler steam stop valves closed (refer to Figure 3). These valves are discussed in detail

Waste heat recovery in motor shipsA diesel engine loses approximately 30% of the energy to the exhaust gases. A turbocharger recover some of it, but there is still heat losses that can be recovered by means of an Exhaust Gas Boiler, EGB. Utilization of the energy in the exhaust gas is restricted due to risk of low temperature corrosion on the gas side of the tubes. The sulphuric acid dew point temperature is assumed to be at 130-140°C. A temperature difference of 40°C must be considered in orderto obtain a certain margin when the gas temperature decreases due to low load on the main engine. This means that an EGB shall notbe designed to reduce the gas temperature at the EGB outlet below 170-180°C at Continuous Service Rating. Besides, at gas temperatures below 170-180°C, the vaporized unburned oil particles in the gas condense to an adhesive mixture of soot and oil resulting introublesome deposits on the tubes and on the heating surface of the EGB.

The reasonable optimal steam production of an EGB where no economizer is incorporated is consequently reached at a steam pressure of 3-4bar (saturated temperature 143-151°C). In practice it is found that the pinch temperature shall be kept at minimum 25°C as a lower temperature difference will substantially increase the heating surface and the price of the EGB.An EGB is normally built to regenerate the heat from comparatively large flue gas quantities at a not very high temperature and with a limited pressure loss. To fulfill these demands, the boilerought to be provided with tubes with extended surface on the gas-side. This can be achieved by means of pinned tubes, as in this example, or finned tubes.

Scotch hybrid boilers

Prud'Hon Capus and Howden-Johnson tried to improve the poor water circulation in the common Scotch fire-tube boilers by adding water tubes in a dry-back combustion chamber.It was claimed that this modification made them 10 per cent more efficient than conventional Scotch fire-tube marine boilers. Both types of boilers failed to make an impact despite of these advantages, the disadvantages of the hybrid arrangement being greater than the advantages.

Prud'Hon Capus marine steam boiler

Page 46: BOILERdocshare02.docshare.tips/files/25397/253975236.pdf · 2017-01-24 · boiler at 120% with boiler steam stop valves closed (refer to Figure 3). These valves are discussed in detail

Thirty-two "Prud'Hon Capus" boilers were fitted onboard the cruise liner "Ile de France" in 1927.The operation pressure was 16 bar

The red coil, to the right of the convection water-tubes, is the superheater.

A Prud'Hon Capus marine steam boiler with the common dry-back combustion chamber open for service.Two fire-tubes and some of the convection water-tubes are visible on this picture.

Page 47: BOILERdocshare02.docshare.tips/files/25397/253975236.pdf · 2017-01-24 · boiler at 120% with boiler steam stop valves closed (refer to Figure 3). These valves are discussed in detail

Howden-Johnson marine steamboiler

Three Howden-Johnson marine boilers were installed onboar T.S. Crispin in 1935.The operation pressure was 15 bar and the steamwas superheated to 307°C

The red coil, between the convection water-tubes and the smoke tubes, is the superheater.

The Howden-Johnson marine steam boiler without the common dry-back combustion chamber mounted.Part of the superheater is visible above the convection water-tubes