2014 Heatcraft Australia HVAC Equipment Price Guide

19
HVAC Equipment

description

2014 Heatcraft Australia HVAC Equipment Price Guide

Transcript of 2014 Heatcraft Australia HVAC Equipment Price Guide

HV

AC

Eq

uip

men

t

104 For friendly service and advice visit your local Heatcraft branch or call 13 23 50

S2: HV

AC

Eq

uip

men

t

HI-WALL SPLITS AND WINDOW UNITS

LENNOX HI-WALL DC INVERTER SPLIT SYSTEM

Part

Number

Cooling

Capacity

(kW)

Heating

Capacity

(kW)

Efficiency Star Rating*

Sound Level

dB (A) Refrig.

Type

L/G Pipe

Size

(inches)

Max.

Pipe

Length

(m)

Max.

Pipe

Elev.

(m)

List Price

Cooling Heating Indoor Outdoor

LNINV26102.60

(0.35 - 3.0)

2.80

(0.75 - 3.5)2.50 2.50

40 / 37 /

35 / 3250 R410A 1/4 x 3/8 15 10 $1,405.80

LNINV35103.50

(0.95 - 4.0)

3.85

(0.88 - 4.33)2.50 2.50

42 / 39 /

36 / 3352 R410A 1/4 x 3/8 20 10 $1,764.71

LNINV52105.20

(0.65 - 6.00)

5.85

(0.9 - 7.00)1.50 1.50

46 / 44 /

40 / 3556 R410A 1/4 x 1/2 20 10 $2,267.39

LNINV63106.30

(0.70 - 7.00)

6.30

(0.95 - 8.00)1.50 1.50

51 / 45 /

42 / 3956 R410A 1/4 x 5/8 25 10 $2,951.72

LNINV70107.00

(1.40 - 8.70)

7.50

(1.05 - 10.00)1.50 1.50

51 / 47 /

43 / 4059 R410A 1/4 x 5/8 25 10 $3,465.11

LNINV80108.00

(1.40 - 8.70)

8.40

(1.05 - 10.00)1.50 1.50

51 / 48 /

43 / 4059 R410A 1/4 x 5/8 30 10 $3,729.98

* When tested in accordance with AS/NZS 3823.2:2013

LENNOX HI-WALL FIXED SPEED SPLIT SYSTEM

Part

Number

Cooling

Capacity

(kW)

Heating

Capacity

(kW)

Efficiency Star Rating*

Sound Level

dB (A) Refrig.

Type

L/G Pipe

Size

(inches)

Max.

Pipe

Length

(m)

Max.

Pipe

Elev.

(m)

List Price

Cooling Heating Indoor Outdoor

LNFS2610 2.7 2.8 3.00 3.00 38 / 32 / 27 54 R410A 1/4 x 3/8 20 8 $1,191.81

LNFS3510 3.5 3.5 3.00 3.00 43 / 36 / 30 54 R410A 1/4 x 1/2 20 8 $1,507.74

LNFS5110 5.3 5.5 2.00 2.00 48 / 43 / 38 60 R410A 1/4 x 1/2 25 10 $1,955.38

LNFS6510 6.5 7.1 2.00 2.00 48 / 43 / 37 60 R410A 3/8 x 5/8 25 10 $2,697.42

LNFS7510 7.6 7.8 2.00 2.00 49 / 45 / 42 60 R410A 3/8 x 5/8 25 10 $3,206.24

* When tested in accordance with AS/NZS 3823.2:2013

LENNOX WINDOW UNIT AIR CONDITIONERS

Part Number

Cooling

Capacity

(kW)

Heating

Capacity

(kW)

Efficiency Star Rating* Noise Level

dB (A)

Refrig. Type

Dimensions

(mm) List PriceCooling Heating

Indoor

LNWR21X 2.2 1.9 2.0 2.0 49 / 47 / 45 R410A 560 x 375 x 668 $1,050.62

LNWR39X 3.9 3.6 2.0 2.0 53 / 51 / 49 R410A 660 x 428 x 700 $1,573.26

LNWR53X 5.3 5.0 2.0 2.0 55 / 53 / 51 R410A 660 x 428 x 700 $1,718.85

LNWR59X 6.0 5.5 2.0 1.5 56 / 54 / 52 R410A 660 x 428 x 700 $1,864.27

* When tested in accordance with AS/NZS 3823.2:2013

Air Conditioners

105

Sec 2: HVAC Equipment

S2: H

VA

C

Eq

uip

men

t

LENNOX RESIDENTIAL SPLIT DUCTED - COOLING ONLY (TOP/VERTICAL DISCHARGE)

Outdoor Part Number

Indoor Part Number

Electrical Phase

Nominal Cooling Capacity

Nominal Heating Capacity

TX Valve Kit to suit

Nominal Air Flow

L/G Pipe Size

(inches) List Price

TSA048S4-1 BCM048 Single 13.0 13.0 Not Required 755 3/8 x 7/8 $3,759.91

TSA060S4-1 BCM060 Single 16.0 16.0 Not Required 945 3/8 x 7/8 $4,439.05

TSA060S4-3 BCM060 Three 16.0 16.0 Not Required 945 3/8 x 7/8 $4,439.05

LENNOX RESIDENTIAL SPLIT DUCTED UNITS - REVERSED CYCLE (TOP/VERTICAL DISCHARGE OUTDOOR UNIT)

Outdoor Part Number

Indoor Part Number

Electrical Phase

Nominal Cooling Capacity

Nominal Heating Capacity

TX Valve Kit to suit

Nominal Air Flow

L/G Pipe Size (in.)

List Price

TPA048S4-1 BCM048 Single 13.0 13.0 Not Required 755 3/8 x 7/8 $4,612.49

TPA060S4-3 BCM060 Three 16.0 16.0 Not Required 945 3/8 x 7/8 $5,535.06

LENNOX DC INVERTER DUCTED SPLIT SYSTEM (SIDE DISCHARGE O/D UNIT)

Part

Number

Cooling

Capacity

(kW)

Heating

Capacity

(kW)

Efficiency

Star Rating* Indoor

Air Flow

(l/s)

Sound Level

dB (A)

Elect. Volt / Hertz / Phase

V / Hz / Ø

L/G Pipe Size

(inch.)

Spigot Sizes (S/R)

mm List PriceCooling Heating Indoor Outdoor

LED735V5 7.35

(3.40 – 8.66)

8.50

(4.40 -

10.2)

3.3 3.7400 / 330

/ 275

42 / 38

/ 3359

240 / 50

/ 1 3/8 x 5/8

1054*185 / $5,326.46

LCD735V5 1061*226

LED104V5 10.40

(5.3 - 12.0)

11.20

(5.7 -

14.0)

3.2 3.5900 / 760

/ 635

49 / 45

/ 4262

240 / 50

/ 1 3/8 x 5/8

1000*253 $6,158.15

LCD104V5 1145*334

LED135V5 13.50

(6.88 - 15.5)

16.00

(8.15 -

19.5)

3.2 3.51000 /

635 / 550

49 / 45

/ 4262

240 / 50

/ 1 3/8 x 3/4

1000*253 $7,779.41

LCD135V5 1145*334

LED168V5 16.80

(8.50 - 19.0)

17.70

(9.0 -

22.0)

3.2 3.4915 / 830

/ 720

49 / 46

/ 4263

240 / 50

/ 1 3/8 x 3/4

1188*385 $8,498.76

LCD168V5 1188*385

* When tested in accordance with AS/NZS 3823.2:2013

Part Number

Cooling

Capacity

(kW)

Heating

Capacity

(kW)

Indoor

Air

Flow

(l/s)

Sound Level

dB (A)Elect.

Volt / Hertz / Phase

V / Hz / Ø

L/G Pipe Size

(inch.)

Max. Total Pipe Length (m) List PriceIndoor Outdoor

LNMLT26 2.6 2.8 166 41/38/30/24 N/A 240 / 50 / 1 1/4 x 3/8 N/A $462.21

LNMLT35 3.5 3.8 188 42/39/31/25 N/A 240 / 50 / 1 1/4 x 3/8 N/A $530.37

LNMLT53 5.3 5.8 222 45/40/37/32 N/A 240 / 50 / 1 1/4 x 1/2 N/A $662.43

LNMLT80

8.0

(2.2 to

10.0)

9.3

(2.8 to

11.0)

N/A N/A 59/56/53 240 / 50 / 1 N/A 70 $3,097.02

LNMLT116

11.6

(2.2 to

14.5)

13.0

(2.47 to

15.34)

N/A N/A 54/51/48 240 / 50 / 1 N/A 80 $5,171.64

* When tested in accordance with AS/NZS 3823.2:2013

LENNOX DC INVERTER MULTI HEAD SPLIT SYSTEM

106 For friendly service and advice visit your local Heatcraft branch or call 13 23 50

S2: HV

AC

Eq

uip

men

t

OPTIONAL ACCESSORIES – (MUST BE ORDERED SEPARATELY)

Part Number Description List Price

700960 Wall Flashing Kit (EXTERNAL ONLY) – 150 mm suits G61E $116.32

51W11 Flush Mount Flue Termination - Suits G61 (2" & 3") $82.34

69M29 Concentric Flue Terminal Kit (2") - Suits G61-070 & 090 $368.54

60L46 Concentric Flue Terminal Kit (3") - Suits G61-110 & 135 $320.48

44W48 LPG Conversion Kit (Field Installation Kit) $189.74

50XCE 50mm x 4 Metre Length Grey Class 12 PVC Pipe $69.41

80XCE 80mm x 4 Metre Length Grey Class 12 PVC Pipe $146.68

2103050 50mm 90° Equal PVC Elbow $10.56

2103080 80mm 90° Equal PVC Elbow $19.21

2117050 50mm 45° Equal PVC Elbow $10.56

2117080 80mm 45° Equal PVC Elbow $25.93

2108050 50mm Equal PVC Socket $7.70

2108080 80mm Equal PVC Socket $18.25

2109080050 80mm to 50mm Reducing PVC Socket $13.44

THERMOSTATS (MUST BE ORDERED SEPARATELY) – REFER TO PAGE 118-119

TRANSITIONS (MUST BE ORDERED SEPARATELY) – REFER TO PAGES 117-118

HIGH EFFICIENCY SERIES

LENNOX INTERNAL HIGH EFFICIENCY MULTI-POSITION GAS FURNACES – G61MP SERIES

Part Number Description Star RatingHeating kW

List Price HIGH heat LOW heat

20W90 G61MPVT-36B-070 5.3 17.9 12.6 $3,091.27

20W91 G61MPVT-60C-090 5.3 23.7 16.7 $3,655.97

20W92 G61MPVT-60C-110 5.3 29.0 21.1 $4,217.86

20W93 G61MPVT-60D-135† 5.3 35.7 25.5 $4,724.60

LENNOX EXTERNAL HIGH EFFICIENCY GAS FURNACES – G61E SERIES

Part Number Description Star RatingHeating kW

List Price HIGH heat LOW heat

20W90E G61EVT-36B-070 5.3 17.9 12.6 $5,185.65

20W91E G61EVT-60C-090 5.3 23.7 16.7 $5,405.76

20W92E G61EVT-60C-110 5.3 29.0 21.1 $5,593.51

20W93E G61EVT-60D-135 5.3 35.7 25.5 $5,813.63

†The G61MPVT-60D-135 can only be installed in horizontal right or down-flow configurations.

LENNOX EXTERNAL HIGH EFFICIENCY GAS FURNACES – G61E SERIES WITH COOLING COIL FITTED

Part Number Description Star Rating Coil TypeTX Valve & Drier

List Price

20W90EC G61EVT-36B-070 with COIL 5.3 76L42 37L51 $6,346.02

20W91EC G61EVT-60C-090 with COIL 5.3 76L46 91M02 $7,026.85

20W92EC G61EVT-60C-110 with COIL 5.3 76L46 91M02 $7,214.58

20W93EC G61EVT-60D-135 with COIL 5.3 76L46 91M02 $7,434.72

Gas Furnaces

For Horizontal applications, to protect against water damage in the event

of a malfunction or blockage in the condensate drain, a safety drain tray

must be installed under the unit.WARNING! !

107

Sec 2: HVAC Equipment

S2: H

VA

C

Eq

uip

men

t

INTERNAL MULTI–POSITION GAS FURNACES - LENNOX MERIT SERIES ML180 SINGLE STAGE

Part Number Description Star Rating Heating kW List Price

Internal ML180 Single Stage

ML180UH070AP36A Internal Furnace 3.8 15.5 $2,213.07

ML180UH090AP48B Internal Furnace 3.7 20.6 $2,372.82

ML180UH110AP36C Internal Furnace 3.8 25.8 $3,173.70

ML180UH110AP60C Internal Furnace* 3.8 25.8 $3,173.70

ML180UH135AP60D Internal Furnace 3.9 31.0 $3,368.60

*Additional Air flow

EXTERNAL GAS FURNACES - LENNOX MERIT SERIES ML180 SINGLE STAGE

Part Number Description Star Rating Coil Type List Price

ML18009048B-E External Furnace 3.8 20.6 $5,156.18

ML18011060C-E External Furnace 3.8 25.8 $5,443.55

ML18013560D-E External Furnace 3.9 31.0 $5,597.02

EXTERNAL GAS FURNACES - LENNOX MERIT SERIES ML180 SINGLE STAGE WITH COOLING COIL FITTED

Part Number Description Star Rating Coil Type TX Valve List Price

ML18009048B-EC External Furnace with coil 3.8 76L42 37L51 $6,096.57

ML18011060C-EC External Furnace with coil 3.8 76L46 91M02 $6,288.15

ML18013560D-EC External Furnace with coil 3.9 76L46 91M02 $6,628.05

THERMOSTATS (MUST BE ORDERED SEPARATELY) – REFER TO PAGE 118-119

TRANSITIONS (MUST BE ORDERED SEPARATELY) – REFER TO PAGES 117-118

OPTIONAL ACCESSORIES – (MUST BE ORDERED SEPARATELY)

Part Number Description List Price

700960 Wall Flashing Kit (External Only) -150 mm suits ML180E/EC $116.32

51W11 Flush Mount Flue Termination - Suits ML180 (2" & 3") $82.34

97W04 LPG Conversion Kit for ML180 Series, (Field Installation) For High Altitude Only 1525 - 1981 m $166.00

96W94 LPG Conversion Kit for ML180 Series (Field Installation) Up to 1524m $166.00

700955 Flue Cowl-Horizontal to suit ML180 Series $175.83

XP0040-33 Flue Assembly for ML180E $410.89

STANDARD EFFICIENCY SERIES

108 For friendly service and advice visit your local Heatcraft branch or call 13 23 50

S2: HV

AC

Eq

uip

men

t

ADD-ON COOLING CONDENSERS & COILS (TO ORDER SEPARATELY)

LENNOX TSA SERIES CONDENSERS – AIR CONDITIONING ONLY

Part Number Condensing Unit Model Number (Cooling Only) Nom kW* Phase L/G Pipe Size (inches) List Price

TSA030S4-1 Condensing Unit - Top Discharge 8.0 1 3/8 x 3/4 $2,938.71

TSA036S4-1 Condensing Unit - Top Discharge 10.0 1 3/8 x 7/8 $3,318.61

TSA048S4-1 Condensing Unit - Top Discharge 12.0 1 3/8 x 7/8 $3,759.91

TSA060S4-1 Condensing Unit - Top Discharge 15.0 1 3/8 x 7/8 $4,439.05

TSA036S4-3 Condensing Unit - Top Discharge 10.0 3 3/8 x 7/8 $3,318.61

TSA048S4-3 Condensing Unit - Top Discharge 13.0 3 3/8 x 7/8 $3,759.91

TSA060S4-3 Condensing Unit - Top Discharge 17.0 3 3/8 x 7/8 $4,439.05

TSA072S4-3 Condensing Unit - Top Discharge 21.0 3 5/8 x 1-1/8 $5,959.20

Add-On Cooling

LENNOX CH23 SERIES COILS – AIR CONDITIONING ONLY

Part Number Model Number CAPACITY (kW*) List Price

Horizontal Slab Coils for Internal Heaters

63J70 CH23-41 10.0 $1,231.45

63J71 CH23-51 12.0 $1,284.42

63J72 CH23-65 16.0 $1,390.37

63K00 CH23-68 18.0 $1,664.88

Requires field installed Chatleff style Expansion Valve – see over page

LENNOX CR33 DOWNFLOW SERIES COILS - AIR CONDITIONING ONLY

Part Number Model Number CAPACITY (kW*) List Price

Downflow Cased Coils for Internal Heaters

92M33 CR33-30/36A-F 10.0 $1,500.69

92M36 CR33-48B-F 12.0 $1,806.82

92M38 CR33-50/60C-F 16.0 $2,028.74

92M39 CR33-60D-F 18.0 $2,145.74

Requires field installed Chatleff style Expansion Valve – see over page

LENNOX CH33 SERIES CASED COILS - AIR CONDITIONING ONLY

Part Number Model Number CAPACITY (kW*) List Price

Horizontal 'A' Framed Cased Coils for Internal Heaters

76L04 CH33-36A-2F 10.0 $1,051.10

76L07 CH33-36B-2F 10.0 $1,096.02

76L09 CH33-44/48B-2F 12.0 $1,237.72

76L11 CH33-48C-2F 13.0 $1,345.14

76L12 CH33-50/60C-2F 16.0 $1,606.56

76L14 CH33-62D-2F 18.0 $1,712.54

Requires field installed Chatleff style Expansion Valve – see over page

LENNOX LCS SERIES CONDENSERS - AIR CONDITIONING ONLY

Part Number Nom kW Capacity (kW*) Phase L/G Pipe Size (inches) List Price

LCS-18C-1X-3 Condensing Unit - Side Discharge 16.60 1 3/8 x 5/8 $5,206.03

LCS-17C-3X-2 Condensing Unit - Side Discharge 17.90 3 3/8 x 5/8 $5,206.03

109

Sec 2: HVAC Equipment

S2: H

VA

C

Eq

uip

men

t

EXPANSION VALVE KITS – CHATLEFF STYLE

Part Number CAPACITY (kW*) List Price

TSA024 to 036 units matched with C33, CR33 and CH23 coils

37L51 Up to 10kW $143.14

TSA048 to 060 units matched with C33, CR33 and CH23 coils

91M02 10 - 18kW $141.43

*Nominal kW Actual condensing unit capacity depends on coil combination. Refer to www.energyrating.gov.au for specific ratings for capacity and efficiency.

LENNOX C33 SERIES UPFLOW UNCASED COILS – AIR CONDITIONING ONLY

Part Number Model Number CAPACITY (kW*) List Price

Upflow Uncased Coils for External Heaters

76L38 C33-30B 8.0 $814.09

76L39 C33-36B 10.0 $850.30

76L42 C33-48B 13.0 $1,033.25

76L46 C33-50/60C 16.0 $1,299.08

SELECTOR CHART FOR G61 SERIES

SELECTOR CHART – FOR LENNOX G61MP & G61E SERIES

Use the selector charts below to choose the required add-on cooling

system for your Lennox or alternative brand furnace.

Look for the furnace model on the left hand column and match up

the most suitable capacity, power supply and coil type from the

options listed.

A full system is made up of a condenser, indoor coil and TX valve.

If transitions are required please refer to the Transitions section on

pages 117.

Furnace Model Number

Cooling

Cap.

Condensing Unit

Cooling Coil Coil Type

TX Valve

& Drier

Single Phase

Unit Three Phase Unit

For Multi Positional Furnaces in Horizontal Mode

G61 MPVT-36B-070

8 TSA030S4-1 N/A 76L07 CASED HORIZONTAL 37L51

10 TSA036S4-1 TSA036S4-3 76L07 CASED HORIZONTAL 37L51

12 TSA048S4-1 TSA048S4-3 76L09 CASED HORIZONTAL 91M02

G61MPVT-60C-090 / 110

12 TSA048S4-1 TSA048S4-3 76L11 CASED HORIZONTAL 91M02

15 / 17TSA060S4-1 N/A 76L12 CASED HORIZONTAL 91M02

LCS-18C-1X-3 N/A 76L12 CASED HORIZONTAL 91M02

17N/A TSA060S4-3 76L12 CASED HORIZONTAL 91M02

N/A LCS-17C-3X-2 76L12 CASED HORIZONTAL 91M02

G61MPVT-60D-135

15 / 17TSA060S4-1 N/A 76L14 CASED HORIZONTAL 91M02

LCS-18C-1X-3 N/A 76L14 CASED HORIZONTAL 91M02

17 N/A TSA060S4-3 76L14 CASED HORIZONTAL 91M02

N/A LCS-17C-3X-2 76L14 CASED HORIZONTAL 91M02

NOTE: All TSA Outdoor units are Vertical discharge and LCS Outdoor units are Side discharge.

LENNOX C33 SERIES UPFLOW CASED COILS – AIR CONDITIONING ONLY

Part Number Model Number CAPACITY (kW*) List Price

Upflow Cased Coils for Internal Heaters

76L25 C33-48B-2F-1 12.0 $965.71

76L28 C33-48C-2F 13.0 $902.78

54M80 C33-50/60C-2F-1 16.0 $1,178.66

54M81 C33-62D-2F-1 18.0 $1,178.66

110 For friendly service and advice visit your local Heatcraft branch or call 13 23 50

S2: HV

AC

Eq

uip

men

t

Furnace Model Number

Cooling

Cap.

Condensing Unit

Cooling Coil Coil Type

TX Valve

& DrierSingle Phase Unit

Three Phase

Unit

For External Furnaces

G61EVT-36B-0708 TSA030S4-1 N/A 76L39 INSIDE HEATER 37L51

10 TSA036S4-1 TSA036S4-3 76L39 INSIDE HEATER 37L51

G61E-60C-090 / 110

12 TSA048S4-1 TSA048S4-3 76L46 INSIDE HEATER 91M02

15/17TSA060S4-1 N/A 76L46 INSIDE HEATER 91M02

LCS-18C-1X-3 N/A 76L46 INSIDE HEATER 91M02

17N/A LCS-17C-3X-2 76L46 INSIDE HEATER 91M02

N/A TSA060S4-3 76L46 INSIDE HEATER 91M02

G61E-60D-135

15/17TSA060S4-1 N/A 76L46 INSIDE HEATER 91M02

LCS-18C-1X-3 N/A 76L46 INSIDE HEATER 91M02

17N/A TSA060S4-3 76L46 INSIDE HEATER 91M02

N/A LCS-17C-3x-2 76L46 INSIDE HEATER 91M02

Note: Capacities listed are ARI Gross ratings for Net Capacity ratings refer to the MEPS Ratings at www.energyrating.gov.au. * List prices include Condensing Unit, Cooling Coil and TX Valve. Gas Furnace & Transitions are additional. Note: All TSA Outdoor units are Vertical discharge and LCS Outdoor units are Side discharge.

SELECTOR CHART FOR G61 SERIES (CON'D)

SELECTOR CHART – FOR LENNOX G61MP & G61E SERIES

Furnace Model Number

Cooling

Cap.

Condensing Unit

Cooling Coil Coil Type

TX Valve

& Drier

Single Phase

Unit Three Phase Unit

For Multi Positional Furnaces In Upflow Mode

G61MPVT-36B-070

8 TSA030S4-1 N/A 76L25 CASED UPFLOW 37L51

10 TSA036S4-1 TSA036S4-3 76L25 CASED UPFLOW 37L51

12 TSA048S4-1 TSA048S4-3 76L25 CASED UPFLOW 91M02

G61MPVT-60C-090 / 110

12 TSA048S4-1 TSA048S4-3 76L28 CASED UPFLOW 91M02

15/17TSA060S4-1 N/A 54M80 CASED UPFLOW 91M02

LCS-18C-1X-3 N/A 54M80 CASED UPFLOW 91M02

17N/A TSA060S4-3 54M80 CASED UPFLOW 91M02

N/A LCS-17C-3X-2 54M80 CASED UPFLOW 91M02

For Multi Positional Furnaces In Downflow Mode

G61MPVT-36B-070

8 TSA030S4-1 N/A 92M36 CASED DOWNFLOW 37L51

10 TSA036S4-1 TSA036S4-3 92M36 CASED DOWNFLOW 37L51

12 TSA048S4-1 TSA048S4-3 92M36 CASED DOWNFLOW 91M02

G61MPVT-60C-090 / 110

12 TSA048S4-1 TSA048S4-3 92M38 CASED DOWNFLOW 91M02

15/17TSA060S4-1 N/A 92M38 CASED DOWNFLOW 91M02

LCS-18C-1X-3 N/A 92M38 CASED DOWNFLOW 91M02

17N/A TSA060S4-3 92M38 CASED DOWNFLOW 91M02

N/A LCS-17C-3X-2 92M38 CASED DOWNFLOW 91M02

G61MPVT-60D-135 15/17

TSA060S4-1 N/A 92M39 CASED DOWNFLOW 91M02

N/A LCS-17C-3X-2 92M39 CASED DOWNFLOW 91M02

N/A TSA060S4-3 92M39 CASED DOWNFLOW 91M02

Note: Cased coil bolts directly onto heater as indicated.

NOTE: All TSA Outdoor units are Vertical discharge and LCS Outdoor units are Side discharge.

111

Sec 2: HVAC Equipment

S2: H

VA

C

Eq

uip

men

t

SELECTOR CHART FOR LENNOX MERIT SERIES ML180 HEATERS

SELECTOR CHART - FOR LENNOX MERIT SERIES FURNACES

Furnace Model

Number

Cooling

Cap.

Condensing Unit

Cooling

Coil Coil Type

TX

Valve

Single Phase

Unit

Three Phase

Unit

For Multi Positional Internal Furnaces in Horizontal Mode

ML180UH070AP36A8 TSA030S4-1 N/A 76L04 HORIZONTAL CASED 'A' FRAME 37L51

10 TSA036S4-1 TSA036S4-3 76L04 HORIZONTAL CASED 'A' FRAME 37L51

ML180UH090AP48B8 TSA030S4-1 N/A 76L09 HORIZONTAL CASED 'A' FRAME 37L51

10 TSA036S4-1 TSA036S4-3 76L09 HORIZONTAL CASED 'A' FRAME 37L51

ML180UH090AP48B10 TSA036S4-1 TSA036S4-3 76L09 HORIZONTAL CASED 'A' FRAME 37L51

12 TSA048S4-1 TSA048S4-3 76L09 HORIZONTAL CASED 'A' FRAME 91M02

ML180UH110AP60C &

ML180UH135AP60D

12 TSA048S4-1 TSA048S4-3 76L14 HORIZONTAL CASED 'A' FRAME 91M02

15 / 17TSA060S4-1 N/A 76L14 HORIZONTAL CASED 'A' FRAME 91M02

LCS-18C-1X-3 N/A 76L14 HORIZONTAL CASED 'A' FRAME 91M02

17N/A TSA060S4-3 76L14 HORIZONTAL CASED 'A' FRAME 91M02

N/A LCS-17C-3X-2 76L14 HORIZONTAL CASED 'A' FRAME 91M02

ML180UH135AP60D 21 N/A TSA072S4-3 76L14 HORIZONTAL CASED 'A' FRAME 91M02

NOTE: All TSA Outdoor units are Vertical discharge and LCS Outdoor units are Side discharge.

Furnace Model

Number

Cooling

Cap.

Condensing Unit

Cooling

Coil Coil Type

TX

Valve

Single Phase

Unit

Th ree Phase

Unit

For Multi Positional Internal Furnaces in Upflow Mode

ML180UH090AP48B8 TSA030S4-1 N/A 76L25 CASED UPFLOW 37L51

10 TSA036S4-1 TSA036S4-3 76L25 CASED UPFLOW 37L51

ML180UH090AP48B10 TSA036S4-1 TSA036S4-3 76L25 CASED UPFLOW 37L51

12 TSA048S4-1 TSA048S4-3 76L25 CASED UPFLOW 91M02

ML180UH110AP60C &

ML180UH135AP60D

12 TSA048S4-1 TSA048S4-3 54M80 CASED UPFLOW 91M02

15 / 17TSA060S4-1 N/A 54M81 CASED UPFLOW 91M02

LCS-18C-1X-3 N/A 54M81 CASED UPFLOW 91M02

17N/A TSA060S4-3 54M81 CASED UPFLOW 91M02

N/A LCS-17C-3X-2 54M81 CASED UPFLOW 91M02

ML180UH135AP60D 21 N/A TSA072S4-3 54M81 CASED UPFLOW 91M02

NOTE: All TSA Outdoor units are Vertical discharge and LCS Outdoor units are Side discharge.

Furnace Model

Number

Cooling

Cap.

Condensing Unit

Cooling

Coil Coil Type

TX

Valve

Single Phase

Unit

Th ree Phase

Unit

For Multi Positional Internal Furnaces in Downflow Mode

ML180UH090AP48B10 TSA036S4-1 TSA036S4-3 92M36 CASED DOWNFLOW 37L51

12 TSA048S4-1 TSA048S4-3 92M36 CASED DOWNFLOW 91M02

ML180UH110AP60C &

ML180UH135AP60D

15 / 17TSA060S4-1 N/A 92M38 CASED DOWNFLOW 91M02

LCS-18C-1X-3 N/A 92M38 CASED DOWNFLOW 91M02

17N/A TSA060S4-3 92M38 CASED DOWNFLOW 91M02

N/A LCS-17C-3X-2 92M38 CASED DOWNFLOW 91M02

Note: Capacities listed are ARI Gross ratings (26.7/19.4 air on & 35°C ambient) obtained from Lennox Industries. For Net Capacity ratings, refer Lennox Technical Bulletin or MEPS Ratings at www.energyrating.gov.au.

NOTE: All TSA Outdoor units are Vertical discharge and LCS Outdoor units are Side discharge.

112 For friendly service and advice visit your local Heatcraft branch or call 13 23 50

S2: HV

AC

Eq

uip

men

t

Part Number

Nominal Air Qty

Cooling

Capacity

(kW)

Condensing Unit

Cooling

Coil Exp. Valve

Litres per

Second

Static

Pressure

(Pa) Single Phase Unit Three Phase Unit

For Brivis Heaters Classic Series – Horizontal Mode

MX21E 700 50 10 TSA036S4-1 TSA036S4-3 76L07 37L51

MX21EXA 740 50 12 TSA048S4-1 TSA048S4-3 76L09 91M02

MX21I 785 50 12 TSA048S4-1 TSA048S4-3 76L09 91M02

MX21IXA 830 50 12 TSA048S4-1 TSA048S4-3 76L09 91M02

BH28E (350mm) 710 125 12 TSA048S4-1 TSA048S4-3 76L09 91M02

BH28E (400mm) 760 125 12 TSA048S4-1 TSA048S4-3 76L09 91M02

MX30E 960 125 15 / 17TSA060S4-1 N/A 76L12 91M02

LCS-18C-1X-3 N/A 76L12 91M02

MX30I 1080 125

15 / 17TSA060S4-1 N/A 76L12 91M02

N/A LCS-17C-3X-2 76L12 91M02

17N/A TSA060S4-3 76L12 91M02

N/A LCS-17C-3X-2 76L12 91M02

MX30IXA

1140 125 15 / 17TSA060S4-1 N/A 76L12 91M02

LCS-18C-1X-3 N/A 76L12 91M02

1140 125 17N/A TSA060S4-3 76L12 91M02

N/A LCS-17C-3X-2 76L12 91M02

MX35I

1160 125 15 / 17TSA060S4-1 N/A 76L12 91M02

LCS-18C-1X-3 N/A 76L12 91M02

1160 125 17N/A TSA060S4-3 76L12 91M02

N/A LCS-17C-3X-2 76L12 91M02

NOTE: All TSA Outdoor units are Vertical discharge and LCS Outdoor units are Side discharge.

SELECTOR CHART - FOR ALTERNATE BRAND GAS FURNACES

Use the selector charts below to choose the required add-on cooling system for your Alternative brand furnace. Look for the furnace model on

the left hand column and match up the most suitable capacity, power supply and coil type from the options listed. A full system is made up of a

condenser, indoor coil and TX valve.

Furnace Model

Number

Cooling

Cap.

Condensing Unit

Cooling

Coil Coil Type

TX

Valve

Single Phase

Unit

Th ree Phase

Unit

FOR EXTERNAL FURNACES

ML18009048B-EC10 TSA036S4-1 TSA036S4-3 76L42 INSIDE HEATER 37L51

12 TSA048S4-1 TSA048S4-3 76L42 INSIDE HEATER 91M02

ML18011060C-EC &

ML18013560D-EC

12TSA048S4-1 TSA048S4-3 76L46 INSIDE HEATER 91M02

TSA060S4-1 N/A 76L46 INSIDE HEATER 91M02

15 / 17LCS-18C-1X-3 N/A 76L46 INSIDE HEATER 91M02

N/A TSA060S4-3 76L46 INSIDE HEATER 91M02

17 N/A LCS-17C-3X-2 76L46 INSIDE HEATER 91M02

NOTE: All TSA Outdoor units are Vertical discharge and LCS Outdoor units are Side discharge.

113

Sec 2: HVAC Equipment

S2: H

VA

C

Eq

uip

men

tFor Brivis Heaters MPS Series – Horizontal Mode

HX15I 695 50 10 TSA036S4-1 TSA036S4-3 76L07 37L51

HX23E 715 50 12 TSA048S4-1 TSA048S4-3 76L09 91M02

HX23I 765 50 12 TSA048S4-1 TSA048S4-3 76L09 91M02

HX23EXA 755 50 12 TSA048S4-1 TSA048S4-3 76L09 91M02

HX23IXA 795 50 12 TSA048S4-1 TSA048S4-3 76L09 91M02

HX30E 850 125

15 / 17TSA060S4-1 N/A 76L12 91M02

LCS-18C-1X-3 N/A 76L12 91M02

17N/A TSA060S4-3 76L12 91M02

N/A LCS-17C-3X-2 76L12 91M02

HX30EXA 985 125

15/ 17TSA060S4-1 N/A 76L12 91M02

LCS-18C-1X-3 N/A 76L12 91M02

17N/A TSA060S4-3 76L12 91M02

N/A LCS-17C-3X-2 76L12 91M02

HX30I 1065 125

15 / 17TSA060S4-1 N/A 76L12 91M02

LCS-18C-1X-3 N/A 76L12 91M02

17N/A TSA060S4-3 76L12 91M02

N/A LCS-17C-3X-2 76L12 91M02

HX30IXA 1095 125

15 / 17TSA060S4-1 N/A 76L12 91M02

LCS-18C-1X-3 N/A 76L12 91M02

17N/A TSA060S4-3 76L12 91M02

N/A LCS-17C-3X-2 76L12 91M02

For Braemar Heaters TH Series - Horizontal Mode

THM623 640 50 10 TSA036S4-1 TSA036S4-3 76L07 37L51

THM6X23 695 100 12 TSA048S4-1 TSA048S4-3 76L09 91M02

THM632 960 50

15 / 17TSA060S4-1 N/A 76L12 91M02

LCS-18C-1X-3 N/A 76L12 91M02

17N/A TSA060S4-3 76L12 91M02

N/A LCS-17C-3X-2 76L12 91M02

THM6X32 1505 100

15 / 17TSA060S4-1 N/A 76L12 91M02

LCS-18C-1X-3 N/A 76L12 91M02

17N/A TSA060S4-3 76L12 91M02

N/A LCS-17C-3X-2 76L12 91M02

TH516 470 50 8 TSA030S4-1 N/A 76L07 37L51

TH520 630 50 10 TSA036S4-1 TSA036S4-3 76L07 37L51

TH523 640 50 10 TSA036S4-1 TSA036S4-3 76L07 37L51

TH5X23 740 50 12 TSA048S4-1 TSA048S4-3 76L09 91M02

TH5X23 755 100 12 TSA048S4-1 TSA048S4-3 76L09 91M02

SELECTOR CHART - FOR ALTERNATE BRAND GAS FURNACES (CONT'D)

Part Number

Nominal Air Qty

Cooling

Capacity

(kW)

Condensing Unit

Cooling

Coil Exp. Valve

Litres per

Second

Static

Pressure

(Pa) Single Phase Unit Three Phase Unit

114 For friendly service and advice visit your local Heatcraft branch or call 13 23 50

S2: HV

AC

Eq

uip

men

t

TH532 935 50

15 / 17TSA060S4-1 N/A 76L12 91M02

LCS-18C-1X-3 N/A 76L12 91M02

17N/A TSA060S4-3 76L12 91M02

N/A LCS-17C-3X-2 76L12 91M02

TH5X32 1070 100

15 / 17TSA060S4-1 N/A 76L12 91M02

LCS-18C-1X-3 N/A 76L12 91M02

17N/A TSA060S4-3 76L12 91M02

N/A LCS-17C-3X-2 76L12 91M02

TH415 / TH315 470/475 50 8 TSA030S4-1 N/A 76L07 37L51

TH420 / TH320 630 50 10 TSA036S4-1 TSA036S4-3 76L07 37L51

TH3X20 / TH4X20 /

THM5X20695 100 12 TSA048S4-1 TSA048S4-3 76L09 91M02

TH425 / TH325 755 50 12 TSA048S4-1 TSA048S4-3 76L09 91M02

TH4X25 / TH3X25 810 100 12 TSA048S4-1 TSA048S4-3 76L09 91M02

TH330 / TH430 /

THM530960 50

15 / 17TSA060S4-1 N/A 76L12 91M02

LCS-18C-1X-3 N/A 76L12 91M02

17N/A TSA060S4-3 76L12 91M02

N/A LCS-17C-3X-2 76L12 91M02

TH4X30 / TH3X30 1050 100

15 / 17TSA060S4-1 N/A 76L12 91M02

LCS-18C-1X-3 N/A 76L12 91M02

17N/A TSA060S4-3 76L12 91M02

N/A LCS-17C-3X-2 76L12 91M02

TH435 1050 50

15 / 17TSA060S4-1 N/A 76L12 91M02

LCS-18C-1X-3 N/A 76L12 91M02

17N/A TSA060S4-3 76L12 91M02

N/A LCS-17C-3X-2 76L12 91M02

NOTE: All TSA Outdoor units are Vertical discharge and LCS Outdoor units are Side discharge.

For Bonaire M Series Heaters

MB4-14 / MB515 480 100 8 TSA030S4-1 N/A 76L07 37L51

MB3-14 / MB3-20 /

MB4-20 / MB521 540 100 8 TSA030S4-1 N/A 76L07 37L51

MB3-30 / MB4-20 XA /

MB4-30 / MB521 XA /

MB530

830 100 12 TSA048S4-1 TSA048S4-3 76L09 91M02

MB3-30XA / MB4-30

XA / MB530 XA1050 100

15 / 17TSA060S4-1 N/A 76L12 91M02

LCS-18C-1X-3 N/A 76L12 91M02

17N/A TSA060S4-3 76L12 91M02

N/A LCS-17C-3X-2 76L12 91M02

NOTE: All TSA Outdoor units are Vertical discharge and LCS Outdoor units are Side discharge.

NOTE: The above information is compiled from publicly available information from manufacturers, the accuracy of which is not the responsibility of Lennox Heating and Air Conditioning. No guarantee

is expressed or implied as to the compatibility or performance of Lennox add-on cooling equipment when used with other brands of furnace.

NOTE: Capacities listed are ARI Gross ratings for Net Capacity ratings refer to the MEPS Ratings at www.energyrating.gov.au. Allowance has been made for stated available static pressure. In most cases, existing ducting should be increased.

* List prices include condensing unit, cooling coil and TX valve but excludes gas furnace and transitions

Part Number

Nominal Air Qty

Cooling

Capacity

(kW)

Condensing Unit

Cooling

Coil Exp. Valve

Litres per

Second

Static

Pressure

(Pa) Single Phase Unit Three Phase Unit

For Braemar Heaters TH Series - Horizontal Mode (cont'd)

SELECTOR CHART - FOR ALTERNATE BRAND GAS FURNACES (CONT'D)

115

Sec 2: HVAC Equipment

S2: H

VA

C

Eq

uip

men

t

Type Requirements Internal Application

External

Application with

Furnace Only

Note - Furnace

Model Numbers

ending in E

Internal Application

with Add On

External

Application

with Add On

Note - Furnace

Model Numbers

ending in EC

Furnace

TransitionsSupplied with

starting collars

Supplied with

starting collars

High Efficiency

G61MPVT- return end caps to nominated round -

G61MPVT-36B- LECB-350mm/400mm N/A LECB-350mm/400mm N/A

G61MPVT-60C- LECC-400mm/450mm N/A LECC-400mm/450mm N/A

G61MPVT-60D- LECD-400mm/450mm N/A LECD-400mm/450mm N/A

G61MPVT- supply end caps to nominated round -

G61MPVT-36B- LSATB-350mm/400mm N/A LSATB-350mm/400mm N/A

G61MPVT-60C- LSATC-400mm/450mm N/A LSATC-400mm/450mm N/A

G61MPVT-60D- LSATD-400mm/450mm N/A LSATD-400mm/450mm N/A

Standard

Efficicency

ML180UH070AP36A - Return end caps to nominated round -

ML180UH070AP36A - LECA-300mm N/A LECA-300mm N/A

ML180UH070AP36A - LECA-350mm N/A LECA-350mm N/A

ML180UH070AP36A - LECA-400mm N/A LECA-400mm N/A

ML180UH090AP48B - LECB-350mm/400mm N/A LECB-350mm/400mm N/A

ML180UH110AP36C - LECC-400mm/450mm N/A LECC-400mm/450mm N/A

ML180UH135AP60D - LECD-400mm/450mm N/A LECD-400mm/450mm N/A

ML180UH070AP36A - Supply end caps to nominated round -

ML180UH070AP36A - LSATA-300mm N/A LSATA-300mm N/A

ML180UH070AP36A - LSATA-350mm N/A LSATA-350mm N/A

ML180UH070AP36A - LSATA-400mm N/A LSATA-400mm N/A

ML180UH090AP48B - LSATB-350mm/400mm N/A LSATB-350mm/400mm N/A

ML180UH110AP36C - LSATC-400mm/450mm N/A LSATC-400mm/450mm N/A

ML180UH135AP60D - LSATD-400mm/450mm N/A LSATD-400mm/450mm N/A

Coils

Cased/Uncased Coil

Note - Cased coil for

Internal with Add-On and

Uncased coil for External

with Add-On

N/A N/A

Cased Coil

EC Furnaces are

supplied with coil

Valves & DriersTx Valve & Drier

Note - Drier supplied as

a kit with TSA Need to

be ordered separately

for LCS. Part Number

LLD053S

Tx Valve - Supplied

with TSA & LCS.

Drier to be ordered

separartely

for LCS.

Part Number

LLD053S

Condenser - TSA or LCS

Thermostats /

Controllers

Thermostats/Controllers

Programmable Y0349, X4147, 51M35 or SMT-770

Non-Programmable 51M33 (2 STAGE FOR G61) , 51M32 or t6620B1024

LEGEND: Required

NOTE: Cased and uncased coil needs to be ordered in accordance to cooling capacity requirements.

CHECK LIST FOR FURNACE AND ADD-ON COOLING SELECTION FOR MOST COMMON APPLICATIONS

Efficiency?

High Efficiency: G61

Mid Efficiency: ML180

Is the furnace to be internal or external?

ML180 & G61MPVT furnaces are internal

ML180E & G61E furnaces are for external use

Heating capacity?

High Efficiency: G61-17.9, 23.7, 29.0 & 35.7 kW

Standard Efficiency: ML180 -15.0,20.0, 25.0 & 31.0 kW

Cooling capacity?

High Efficiency: G61-36 <12.2 kW (TSA), G61-60 <17.8 kW (TSA/LCS)

Standard Efficiency: ML180<10.0 kW (TSA), ML180<13.1 kW (TSA),

ML180<17.4 kW (TSA/LCS)

116 For friendly service and advice visit your local Heatcraft branch or call 13 23 50

S2: HV

AC

Eq

uip

men

t

TRANSITIONS

LENNOX G61 & ML180 WITH CASED COIL

LENNOX HEATER WITH REMOTE ADD-ON COIL

G61 & ML180 Heater in Horizontal Orientation

Return Air –

End Cap

(LEC xx)

Supply Air – Furnace

to Nominated

Round Transition

(LSAT xx)

Coil to Nominated

Round Transitions

(LTCC xx)

LENNOX CH23 or CH33 Horizontal Add-on Coil

Note: If installing in attic or roof space, both Add-on Coil & G61 Condensing Furnace will require a drain tray

G61 & ML180 Heater in Horizontal Orientation

Return Air – End Cap

(LEC XX) Draintray

(LDTCC XX)

Draintray

(LDTCC XX)Draintray

(LDTEC XX)

Supply Air – Furnace to

Nominated Round Transition

(LSAT XX)

Lennox CH33 Horizontal Add-on Coil

Ducted Split Cooling & Heat Pump

Note: If installing in attic or roof space, both G61 & Add-on Coil will require a drain tray

117

Sec 2: HVAC Equipment

S2: H

VA

C

Eq

uip

men

t

TRANSITIONS, COIL ADAPTORS & DRAIN TRAYS FOR LENNOX COILS, FAN COILS & FURNACES

Part Number Gas Furnace To Nominated Round List Price

Return Air Caps to Furnace

LECA-350 ML180UH070AP36A 350mm $115.00

LECA-400 ML180UH070AP36A 400mm $115.00

LECB-350 ML180UH090AP48B 350mm $97.94

LECC-400 ML180UH110AP36C 400mm $97.94

LECD-400 ML180UH135AP60D 450mm $97.94

LECB-350 G61MPVT-36B-070 350mm $100.88

LECB-400 G61MPVT-36B-070 400mm $101.85

LECC-400 G61MPVT-60C-090/110 400mm $100.88

LECC-450 G61MPVT-60C-090/110 450mm $100.88

LECD-400 G61MPVT-60D-135 400mm $100.88

LECD-450 G61MPVT-60D-135 450mm $100.88

Supply Air Transition for Heaters

LSATA-350 ML180UH070AP36A 400mm $200.85

LSATA-400 ML180UH070AP36A 400mm $200.85

LSATB-350 ML180UH090AP48B 350mm $184.57

LSATC-400 ML180UH110AP36C 400mm $184.57

LSATD-400 ML180UH135AP60D 450mm $188.15

LSATB-400 G61MP-36B-070 400mm $188.15

LSATC-400 G61MP-60C-090/110 400mm $184.57

LSATC-450 G61MP-60C-090/110 450mm $184.57

LSATD-400 G61MP-60D-135 400mm $188.15

LSATD-450 G61MP-60D-135 450mm $184.57

End Plate for CH33, C33, Cased Coils

LEPB-350 CH33-36/44/48-B 350mm $61.00

LEPB-400 CH33-36/44/48-B 400mm $61.00

LEPC-350 CH33-48/50/60-C 350mm $61.00

LEPC-400 CH33-48/50/60-C 400mm $61.00

LEPD-400 CH33-62D 400mm $59.26

LEPD-450 CH33-62D 450mm $61.00

Note: For drawings of typical installations, see page 116

TRANSITIONS, COIL ADAPTORS & DRAIN TRAYS FOR LENNOX COILS, FAN COILS & HEATERS

Part Number Coil To Nominated Round List Price

Transition from horizontal coil to duct

LSATB-350 CH33-36/44B 350mm $184.57

LSATB-400 CH33-36/44B 400mm $188.15

LSATC-400 CH33-50/60C 400mm $184.57

LSATC-450 CH33-50/60C 450mm $184.57

LSATD-400 CH33-62D 400mm $188.15

LSATD-450 CH33-62D 450mm $184.57

LTCC05-350 CH23-41 350mm $140.26

LTCC07-400 CH23-51 400mm $157.37

LTCC08-400 CH23-65 400mm $157.37

LTCC08-450 CH23-65 450mm $157.37

LTCC08-500 CH23-65 500mm $174.30

LTCC09-400 CH23-68 400mm $171.06

118 For friendly service and advice visit your local Heatcraft branch or call 13 23 50

S2: HV

AC

Eq

uip

men

t

TRANSITIONS, COIL ADAPTORS & DRAIN TRAYS FOR LENNOX COILS, FAN COILS & HEATERS

Part Number Coil To Nominated Round List Price

Transition from horizontal coil to duct cont'd

LTCC09-450 CH23-68 450mm $171.06

LTCC09-500 CH23-68 500mm $166.17

Drain trays

LDTAC03 CH23-41 COOLING COIL $121.39

LDTAC04 CH23-51 COOLING COIL $142.18

LDTAC05 CH23-65 COOLING COIL $142.18

LDTAC06 CH23-68 COOLING COIL $170.63

LDTAC15-135 G61MPVT-60D-135 HEATER $227.90

LDTCC CH33 CASED COILED $126.78

Note: For drawings of typical installations, see page 116

TRANSITION FOR DC INVERTER DUCTED SPLIT SYSTEM

Part Number To Suit To Nominated Round No. of Outlets UOM List Price

LED735V5-RET LED/LCD 735V5 1061 X 226MM 1 EA $171.15

LED735V5-SUP LED/LCD 735V5 1054 X 185MM 1 EA $171.15

LED104/135V5RET LED/LCD 130V5 1145 X 334MM 1 EA $210.00

LED104/135V5SUP LED/LCD 104V5 1000 X 253MM 1 EA $210.00

LED168V5-RET LED/LCD 168V5 1188 X 385MM 1 EA $210.00

LED168V5-SUP LED/LCD 168V5 1188 X 385MM 1 EA $210.00

ACCESSORIES

HUMIDIFIER

Part Number Description List Price

Y2786 LENNOX BY-PASS HUMIDIFIER HCWB3-17 240/50/1 PHASE (transformer not included) $783.82

60J43 LENNOX 240x24 TRANSFORMER $77.17

X8304 MERV 10 EXPANDABLE FILTER KIT (CONTAINS MERV 10 FILTERS (DIMS 508 X 635 X 127MM) WITH FRAMES) $265.00

X6673 MERV 10 EXPANDABLE REPLACEMENT FILTERS TO GO WITH x8304 $88.00

ACCESSORIES – (MUST BE ORDERED SEPARATELY)

Part Number Description List Price

52P97 Current Sensing Relay $350.18

* Required for Lennox Humidifier for use with third party gas furnaces without accessory terminal connections in unit wiring box.

THERMOSTATS – (MUST BE ORDERED SEPARATELY)

Part Number Description USED WITH List Price

Y2081 Comfortsense 7000 - 24V ThermostatFURNACE/ADD ON/SPLIT DUCTED

(TPA UNITS)/ROOFTOP PACKAGE $457.95

X4147Touchscreen 5000 - Programmable 2 Heat /

2 Cool

FURNACE/ADD ON/SPLIT DUCTED

(TPA UNITS)/ROOFTOP PACKAGE $457.26

For Horizontal applications, to protect against water damage in the event

of a malfunction or blockage in the condensate drain, a safety drain tray

must be installed under the unit.WARNING! !

119

Sec 2: HVAC Equipment

S2: H

VA

C

Eq

uip

men

t

COMMERCIAL UNIT & DUCT HEATER RANGE

DUCT HEATERS

Part Number Model Number Kw Airflow L/S List Price

LF24 Series Unit Heaters

16J70A LF24-100A 21.2 745 $4,226.48

23W54A LF24-145A 32.1 860 $4,986.50

89K88A LF24-200A 42.5 860 $4,696.07

26J78A LF24-250A 53.1 1725 $5,719.82

26J80A LF24-300A 63.6 1725 $6,196.47

65K97A LF24-345A 72.6 1725 $6,514.23

86K41A LF24-400A 82.1 1725 $6,832.02

LD24 Series Duct Heaters

32K55A LD24-100A 20.6 450-1700 $3,913.41

32K56A LD24-125A 25.7 550-2100 $4,130.98

32K57A LD24-150A 30.9 700-2600 $4,226.48

32K58A LD24-200A 41.1 750-1800 $4,925.39

32K59A LD24-250A 51.3 1000-2300 $5,165.69

32K60A LD24-300A 61.8 1100-2700 $5,719.82

Optional Accessories (Must Be Ordered Separately) - Only To Be Used With LF24'S

45L88 LPG Conversion Kit for LF24 250-300 $498.94

20L06 LPG Conversion Kit for LF24 400 $302.15

51M37 Merit 3000 - Programmable 3 Heat / 2 Cool Heat Pump SPLIT DUCTED (TPA UNITS) $365.59

51M35 Merit 3000 - Programmable 2 Heat / 2 Cool Heat Cool FURNACE/ADD ON/ROOFTOP PACKAGE $231.48

51M33 Merit 3000 - Manual 2 Heat / 1 Cool Heat Pump SPLIT DUCTED (TPA UNITS) $224.15

51M32 Merit 3000 - Manual 1 Heat / 1 Cool Heat Cool FURNACE/ADD ON/ROOFTOP PACKAGE $159.74

X4148 Outdoor Sensor to suit Touchscreen Thermostat TO READ OUTDOOR AMBIENT TEMP $75.35

X2658 Outdoor Sensor to suit Comfortsense Thermostat TO READ OUTDOOR AMBIENT TEMP $63.90

DT90A1008 Digital Non Prog, 1 Heat or 1 Cool,On/Off SPLIT DUCTED (TPA UNITS) $206.30

KJR-12B WIRED CONTROLLER (NON PROGRAMMABLE) SPLIT DUCTED INVERTERS (LED/LCD) $165.02

ULTRAPLUS Universal Remote Control (Blue Packaging) FOR ALL SPLIT BRANDS INCLUDING LENNOX $69.89

ESRUniversal Energy Saving Remote With Variable

Temperature Setting (Green Packaging)

FOR ALL SPLIT BRANDS INCLUDING LENNOX

(Hotel/Motel Applications) $69.89

ACCESSORIES (CONT'D)

LENNOX COMMERCIAL UNIT & DUCT HEATER RANGE

Outdoor Part

Number Qty

Indoor Part

Number

TX Valve

Kit to suit

Nom. Cooling

Capacity (kW)

Nom. Heating

Capacity (kW)

Nominal Air Flow

(L/s) List Price

TPA090S4S 1 TAA090S4D Not Required 23.0 22.5 1415 $13,710.26

TPA120S4S 1 TAA120S4D Not Required 30.0 29.5 1890 $16,861.68

TPA090S4S 2* TAA180S4D 47W48 46.0 45.0 2830 $24,743.11

TPA120S4S 2* TAA240S4D 50W73 60.0 59.0 3775 $31,027.03

* For models TPA090S4S & TPA120S4S two outdoor units are required

Part Number Description USED WITH List Price

THERMOSTATS – (MUST BE ORDERED SEPARATELY) (CONT'D)

120 For friendly service and advice visit your local Heatcraft branch or call 13 23 50

S2: HV

AC

Eq

uip

men

t

LENNOX COMMERCIAL HEATPUMP CONDENSING UNITS

Part number Description Dimensions mm (L x W x H) List Price

TPA090S4S 23kW Condenser 1051 x 1470 x 1238 $8,450.84

TPA120S4S 30kW Condenser 1051 x 1470 x 1238 $10,909.05

LENNOX COMMERCIAL HEATPUMP FANCOIL UNITS

Part number Description Dimensions mm (L x W x H) List Price

TAA090S4D 23kW Air Handler 1391 x 1302 x 749 $5,259.42

TAA120S4D 30kW Air Handler 1391 x 1708 x 749 $5,952.63

TAA180S4D 46kW Air Handler 1391 x 2445 x 749 $7,326.85

TAA240S4D 58kW Air Handler 1391 x 2445 x 749 $8,652.41

50W73 Check valve kit for TAA240 $556.52

Lennox Rooftop Packaged UnitsEvery Lennox rooftop product is engineered for durability and is

backed with a long-lasting warranty. High-quality components

include a heavy-gauge galvanized steel cabinet with a two-layer

paint finish and scroll compressors. In-built safety switches and

diagnostics protect the system’s critical components against

catastrophic failure, protecting businesses against high replacement

costs and down time.

Durable construction with full perimeter base rail

Fork Slots in base rail for ease of transportation

Easy access with large service panels

Industry leading efficiencies

Multi-stage cooling and heating control

2 Year Limited Warranty on Parts

LENNOX REVERSE CYCLE ROOFTOP UNITS

Part Number

Cooling

Capacity*

(kW)

Heating

Capacity*

(kW)

Nominal

Airflow (L/s)

Efficiency Rating

EER/COP

Dimensions

L x W x H (mm) List Price

KHA036S4B 9.3 9.6 566 3.67 / 4.18 2165 x 1192 x 987 P.O.A.

KHA048S4B 12.4 12.6 755 3.49 / 4.17 2165 x 1192 x 987 P.O.A.

KHA060S4B 15.5 16.0 944 3.41 / 4.05 2165 x 1192 x 1191 P.O.A.

KHA072S4B 17.0 15.8 1040 3.59 / 3.80 2165 x 1192 x 1191 P.O.A.

KHA092S4B 21.6 20.4 1416 3.77 / 4.19 2521 x 1473 x 1270 P.O.A.

KHA120S4B 28.6 27.3 1888 3.41 / 3.93 2521 x 1473 x 1270 P.O.A.

KHA150S4B 32.5 31.8 2124 3.26 / 3.58 2521 x 1473 x 1270 P.O.A.

KHA180S4B 43.2 39.9 2832 3.35 / 3.78 3289 x 2315 x 1378 P.O.A.

KHA240S4B 54.3 49.7 3540 3.25 / 3.84 3289 x 2315 x 1378 P.O.A.

* When tested in accordance with AS/NZS 3823.2

13 23 50heatcraft.com.au

See our full range of high-performance Schneider Electric HVAC field devices,

exclusive to Heatcraft.

When it comes to reliable and efficient performance, Lennox Rooftop Units have

always been a stand-out for light commercial applications. Now we’ve built more

flexibility into the line by offering you a complete range of Lennox Rooftop units -

an excellent choice for virtually any application.

For more information, contact your Heatcraft Account Manager.

FlexyTM Landmark®Energence®

BalticTM