Transcript of 2010-03-11 Presentation Hotel Lighting
![Page 1: 2010-03-11 Presentation Hotel Lighting](https://reader030.fdocuments.net/reader030/viewer/2022021215/577d33cf1a28ab3a6b8bcf22/html5/thumbnails/1.jpg)
8/8/2019 2010-03-11 Presentation Hotel Lighting
http://slidepdf.com/reader/full/2010-03-11-presentation-hotel-lighting 1/12
HOTEL LIGHTING
![Page 2: 2010-03-11 Presentation Hotel Lighting](https://reader030.fdocuments.net/reader030/viewer/2022021215/577d33cf1a28ab3a6b8bcf22/html5/thumbnails/2.jpg)
8/8/2019 2010-03-11 Presentation Hotel Lighting
http://slidepdf.com/reader/full/2010-03-11-presentation-hotel-lighting 2/12
![Page 3: 2010-03-11 Presentation Hotel Lighting](https://reader030.fdocuments.net/reader030/viewer/2022021215/577d33cf1a28ab3a6b8bcf22/html5/thumbnails/3.jpg)
8/8/2019 2010-03-11 Presentation Hotel Lighting
http://slidepdf.com/reader/full/2010-03-11-presentation-hotel-lighting 3/12
Conception of an alternative lighting
for energy optimization
![Page 4: 2010-03-11 Presentation Hotel Lighting](https://reader030.fdocuments.net/reader030/viewer/2022021215/577d33cf1a28ab3a6b8bcf22/html5/thumbnails/4.jpg)
8/8/2019 2010-03-11 Presentation Hotel Lighting
http://slidepdf.com/reader/full/2010-03-11-presentation-hotel-lighting 4/12
EXEMPLARY:
EUROPE HOTELS, STUTTGART
![Page 5: 2010-03-11 Presentation Hotel Lighting](https://reader030.fdocuments.net/reader030/viewer/2022021215/577d33cf1a28ab3a6b8bcf22/html5/thumbnails/5.jpg)
8/8/2019 2010-03-11 Presentation Hotel Lighting
http://slidepdf.com/reader/full/2010-03-11-presentation-hotel-lighting 5/12
THE EASY WAY
TO GET YOUR ENERGY-SAVING
LED.NEXT-LIGHTING
![Page 6: 2010-03-11 Presentation Hotel Lighting](https://reader030.fdocuments.net/reader030/viewer/2022021215/577d33cf1a28ab3a6b8bcf22/html5/thumbnails/6.jpg)
8/8/2019 2010-03-11 Presentation Hotel Lighting
http://slidepdf.com/reader/full/2010-03-11-presentation-hotel-lighting 6/12
SIMPLE REPLACEMENT
![Page 7: 2010-03-11 Presentation Hotel Lighting](https://reader030.fdocuments.net/reader030/viewer/2022021215/577d33cf1a28ab3a6b8bcf22/html5/thumbnails/7.jpg)
8/8/2019 2010-03-11 Presentation Hotel Lighting
http://slidepdf.com/reader/full/2010-03-11-presentation-hotel-lighting 7/12
11:15
Start of replacement of the halogen lighting system
14:45
End of replacement. Complete corridor lighting now
in Nimbus Modul Q 36 Hotel LED
![Page 8: 2010-03-11 Presentation Hotel Lighting](https://reader030.fdocuments.net/reader030/viewer/2022021215/577d33cf1a28ab3a6b8bcf22/html5/thumbnails/8.jpg)
8/8/2019 2010-03-11 Presentation Hotel Lighting
http://slidepdf.com/reader/full/2010-03-11-presentation-hotel-lighting 8/12THE PRODUCT
122
1 2 2
1 0
1 0 3
8
FOR DIRECT MOUNTING
FOR CAVITY MOUNTING
MODUL Q 36 HOTEL LED
-8 W POWER SUPPLY, 24V DC
-LUMINOUS FLUX APPROX. 470 lm
-COLOUR TEMPERATURE 3000K
-LIGHT DISTRIBUTION 95% DOWNWARDS
-DEGREE OF PROTECTION IP20
![Page 9: 2010-03-11 Presentation Hotel Lighting](https://reader030.fdocuments.net/reader030/viewer/2022021215/577d33cf1a28ab3a6b8bcf22/html5/thumbnails/9.jpg)
8/8/2019 2010-03-11 Presentation Hotel Lighting
http://slidepdf.com/reader/full/2010-03-11-presentation-hotel-lighting 9/12
Comparison of one year of operation and maintenance costs
CALCULATION
area 1 Residential lobby
number of luminaires
power supply
combustion period/ day
combustion period/ year
running time
project cost / luminaire
total investment cost
Nimbus Modul Q 36 Hotel LED 8 W halogen downlight 50 W
200
8
24
365
1
280,00
56.000,00
luminaire
200
50
24
365
1
65,00
13.000,00
parts
watt
hours
days
year
AU$
AU$
parts
watt
hours
days
year
AU$
AU$
cost of operation
maintenance cost
cost of operation and maintenance
economisation
amortisation
3.083,52 AU$
0 AU$
3.083,52 AU$ -
= 26.188,48
In a period of one year the Nimbus LED.next lighting savescompared to a conventional lighting 26.188,48 AU$ at operation costs.
The lighting system with 200 Modul Q 36 Hotel LED amorts itself compared
to the conventional lighting system in 1,6 years.
expenses during one year
19.272,00 AU$
10.000,00 AU$
29.272,00 AU$
AU$
The present evaluation was calculated on basis of the following parameters:
energy rate 22 ct / kwh
maintenance and labour cost ( approx. 9 min / lamp change a 50 AU$/h) + lamps cost 5 $ / pc
![Page 10: 2010-03-11 Presentation Hotel Lighting](https://reader030.fdocuments.net/reader030/viewer/2022021215/577d33cf1a28ab3a6b8bcf22/html5/thumbnails/10.jpg)
8/8/2019 2010-03-11 Presentation Hotel Lighting
http://slidepdf.com/reader/full/2010-03-11-presentation-hotel-lighting 10/12
![Page 11: 2010-03-11 Presentation Hotel Lighting](https://reader030.fdocuments.net/reader030/viewer/2022021215/577d33cf1a28ab3a6b8bcf22/html5/thumbnails/11.jpg)
8/8/2019 2010-03-11 Presentation Hotel Lighting
http://slidepdf.com/reader/full/2010-03-11-presentation-hotel-lighting 11/12
![Page 12: 2010-03-11 Presentation Hotel Lighting](https://reader030.fdocuments.net/reader030/viewer/2022021215/577d33cf1a28ab3a6b8bcf22/html5/thumbnails/12.jpg)
8/8/2019 2010-03-11 Presentation Hotel Lighting
http://slidepdf.com/reader/full/2010-03-11-presentation-hotel-lighting 12/12