2009. 2 OfficeServ 7070 Introduction.. 1/? ■ Compatibility with b’ds of OfficeServ 7100 ■...

9
2009. 2 OfficeServ 7070 Introduction.

Transcript of 2009. 2 OfficeServ 7070 Introduction.. 1/? ■ Compatibility with b’ds of OfficeServ 7100 ■...

Page 1: 2009. 2 OfficeServ 7070 Introduction.. 1/? ■ Compatibility with b’ds of OfficeServ 7100 ■ SPNet connectivity with OfficeServ 7030/7100/7200/7400 ■ No.

2009. 22009. 2

OfficeServ 7070 Introduction.

Page 2: 2009. 2 OfficeServ 7070 Introduction.. 1/? ■ Compatibility with b’ds of OfficeServ 7100 ■ SPNet connectivity with OfficeServ 7030/7100/7200/7400 ■ No.

2/?

■ Compatibility with b’ds of OfficeServ 7100

■ SPNet connectivity with OfficeServ 7030/7100/7200/7400

■ No cabinet expansion

■ Identical S/W and Terminals to 7000 series

■ IP Phone, WiFi phone and SIP Trunk Connectivity

■ IP Enabled platform

- TDM config. : Max. 58 ports (Trunk + Station)

Max. 30 E1 PRI channel + 44 ports (TDM terminals)

- IP config. : Max. 60 ports (8 SIP Trunk + 52 Station)

- Basic embedded config.

: 4Trunk + 4DLI + 8SLI, (BMP + B8S)

4ch AA, 4ch VMS, 8MGI, 1LAN for programming and connection to IP switch

- Common resources

: 2 MOH(1 internal, 1 external), 1 external paging

■ Main Target

- Small & medium Biz. 12 to 50 extensions

- Replacing OfficeServ 100

Overview

Page 3: 2009. 2 OfficeServ 7070 Introduction.. 1/? ■ Compatibility with b’ds of OfficeServ 7100 ■ SPNet connectivity with OfficeServ 7030/7100/7200/7400 ■ No.

3/?

■ Mother boards

- BMP

: Main Processor, 4 DLI embedded, enabling 2 D B’ds to place on BMP

- B8S

: 8 SLI + 4 ATrunk embedded, enabling 3 D B’ds to place on B8S, connected to BMP

- E8S

: 8 SLI embedded, enabling 3 D B’ds to place on E8S, connected to B8S

■ Daughter boards

- Trunk b’d : 4TRK, PRI (E1 PRI, R2 not supported)

- Station b’d : 4SLI, 4SL2(New), 4DLI

Location 4DLM 4SLM 4SL2 4TRM PRM

BMP

LOC1 ● ● ●   ●

LOC2 ● ● ●    

LOC3          

B8S

LOC1 ● ● ● ●  

LOC2 ● ● ● ●  

LOC3 ● ● ● ●  

E8S

LOC1 ● ● ● ●  

LOC2 ● ● ● ●  

LOC3 ● ● ● ●  

[ Location table of

feature boards ]

Page 4: 2009. 2 OfficeServ 7070 Introduction.. 1/? ■ Compatibility with b’ds of OfficeServ 7100 ■ SPNet connectivity with OfficeServ 7030/7100/7200/7400 ■ No.

4/?

Embedded Voice mail, AA and VoIPEmbedded Voice mail, AA and VoIP

- 4 VMS (Max. Recording 8 hours), 4 AA

- VoIP : Max. 8 channel (independent VMS & AA channel)

- License Key

SIP Trunk and StationSIP Trunk and Station

- Need a commercial IP switch for IP station

CIDCID

Wall Mountable Enhanced DesignWall Mountable Enhanced Design

All RJ-45 connectorsAll RJ-45 connectors

- 4ports per 1 RJ-45 connector- 4ports per 1 RJ-45 connector

- Connection table label- Connection table label

Cable DuctCable Duct

- Enable separation from main cabinet- Enable separation from main cabinet

Page 5: 2009. 2 OfficeServ 7070 Introduction.. 1/? ■ Compatibility with b’ds of OfficeServ 7100 ■ SPNet connectivity with OfficeServ 7030/7100/7200/7400 ■ No.

5/?

Category Each Total

Trunk

Analog 2858

PRI (E1 PRI) 30

SIP 816

SPNet port 8

Station

SLT 48

52

Digital phone 36

Samsung IP phone 32

Samsung WiFi phone 32

3rd party SIP phone 32

Others

AA port (G.711) 4 4

VM port (G.711) 4 4

MGI port (G.729) 8 8

Maximum CapacityMaximum Capacity

11stst target market : Korea (Oct. 08 ) target market : Korea (Oct. 08 )

Page 6: 2009. 2 OfficeServ 7070 Introduction.. 1/? ■ Compatibility with b’ds of OfficeServ 7100 ■ SPNet connectivity with OfficeServ 7030/7100/7200/7400 ■ No.

6/?

Cabinet Internal Configuration

Design

PSUBMP B8S & E8S

(LED)

RJ-45 Jack

Reserved

D B'd

D B'd D B'd

D B'd

D B'd

● ●

Switch

Power Jack

all-Option D B'd E8S B'd

B8S B'dBMP B'd

[ Top view ]

[ Front view ]

Page 7: 2009. 2 OfficeServ 7070 Introduction.. 1/? ■ Compatibility with b’ds of OfficeServ 7100 ■ SPNet connectivity with OfficeServ 7030/7100/7200/7400 ■ No.

7/?

Cabinet Images

Design

Page 8: 2009. 2 OfficeServ 7070 Introduction.. 1/? ■ Compatibility with b’ds of OfficeServ 7100 ■ SPNet connectivity with OfficeServ 7030/7100/7200/7400 ■ No.

8/?

Cabinet Images

Design

Page 9: 2009. 2 OfficeServ 7070 Introduction.. 1/? ■ Compatibility with b’ds of OfficeServ 7100 ■ SPNet connectivity with OfficeServ 7030/7100/7200/7400 ■ No.

9/?

Cabinet Images

Design