2 Connecting PLC to Profi Cassy

8
1 T9.4.1.2 LD Project sheets Technique Connecting the Profi Cassy to the Profibus 1. Open a project in the Step 7 Software 2. double click on “Hardware” 3. Install the File LD066f.gsd from the Profi Cassy CD

description

casy lab

Transcript of 2 Connecting PLC to Profi Cassy

Page 1: 2 Connecting PLC to Profi Cassy

1

T9.4.1.2

LD

Project sheets

Technique

Connecting the Profi Cassy to the Profibus

1. Open a project in the Step 7 Software 2. double click on “Hardware”

3. Install the File LD066f.gsd from the Profi Cassy CD

Page 2: 2 Connecting PLC to Profi Cassy

2

T9.4.1.2

LD

Project sheets

Technique

Connecting the Profi Cassy to the Profibus

4. Open : Options configure Network

5.The following window opens

Page 3: 2 Connecting PLC to Profi Cassy

3

T9.4.1.2

LD

Project sheets

Technique

Connecting the Profi Cassy to the Profibus

6.right mouse click on DP-Interface. After that open "objects properties"

7. Adress the network with an address different from the other addresses and press " new"

Page 4: 2 Connecting PLC to Profi Cassy

4

T9.4.1.2

LD

Project sheets

Technique

Connecting the Profi Cassy to the Profibus

8. The following window opens. Press ok

Page 5: 2 Connecting PLC to Profi Cassy

5

T9.4.1.2

LD

Project sheets

Technique

Connecting the Profi Cassy to the Profibus

9. After that you will see the Profibus be connected to the PLC

10. Right mouse click on the DP- interface and choose "Master System"

Page 6: 2 Connecting PLC to Profi Cassy

6

T9.4.1.2

LD

Project sheets

Technique

Connecting the Profi Cassy to the Profibus

11. Press ok

12. Klick on the DP-Interface of the Simatic 300 Station. Choose the Profi Cassy from the catalogue on the right side and connect it to the Profi-Bus by drag and drop. You will be asked to choose an address. Choose an address not used before and press "OK". After that your Profi-Cassy is connected to the Profi-Bus.

Page 7: 2 Connecting PLC to Profi Cassy

7

T9.4.1.2

LD

Project sheets

Technique

Connecting the Profi Cassy to the Profibus

13. After that compile and save the system

14. Go back to the window "Configuration". You can see the Profi-Cassy is connected to PLC by Profi-Bus

Page 8: 2 Connecting PLC to Profi Cassy

8

T9.4.1.2

LD

Project sheets

Technique

Connecting the Profi Cassy to the Profibus

15. Clicking on the Profi-Cassy who can see, the adresses of the input and output ports of the Profi-Cassy. By clicking on the boards you can change their addresses.