2-3+nm Solar Marine Light · 2017. 9. 7. · 2-3+nm Solar Marine Light. Latest products and...
Transcript of 2-3+nm Solar Marine Light · 2017. 9. 7. · 2-3+nm Solar Marine Light. Latest products and...
Large internal solar moduleCharges the battery during
daylight hours
6 ultra-high intensity LEDs With an operatinal life in excess of 100,000 hours LEDs result in enormous
savings in maintenance costs
Lens and base moulded from UV-stabilised
LEXAN® polycarbonateProvides excellent impact-resistance
Bird deterrent spikeAn environmentally-friendly spike
deters unwelcome bird life
LED lens and Sealite’s 360° 2PQLGLUHFWLRQDO�/('�5HÀHFWRU
(US Pat. No. 6,667,582. / AU Pat. No. 778,918)
Complex shaped lenses, coupled with Sealite’s superior lens manufacturing
capabilities give superior optical performance
Automatic night activationThe lantern will automatically begin operation at dusk, once the ambient OLJKW�WKUHVKROG�GURSV�VXI¿FLHQWO\
Internal user-replaceable battery in sealed compartment (IP68 rating)
Allows the battery to be replaced after years of service – don’t throw the light
away at the end of the battery service life
SL602-3+nm Solar Marine Light
Latest products and information available at www.sealite.com5
SL60 2-3nm+ Solar Marine Light
SL60 ModelThe Sealite SL60 is the most popular and versatile 2-3nm+ solar marine light available. Made from tough, durable polycarbonate and using the latest high-intensity LEDs, no expense has been spared in the design and development of this lantern. Installation takes just minutes, and a permanent ON/OFF switch allows for easy storage.The unit is ideal for navigation, hazard lighting, aquaculture, perimeter lighting and a range of other applications.
63(&,),&$7,216��Light CharacteristicsLight Source 6 ultra-high intensity LEDsAvailable Colours Red, Green, White, Yellow, Blue3HDN�,QWHQVLW\��FG� Red - 19.1 Green - 22.1 White - 20.2 Yellow - 16.3Visible Range (nm) 2-3++RUL]RQWDO�2XWSXW��GHJUHHV� 360Vertical Divergence (degrees) 95HÀHFWRU�7\SH 2PQLGLUHFWLRQDO������/('�5HÀHFWRU��86�3DW��1R�������������$8�3DW��1R����������Available Flash Characteristics 8S�WR�����,$/$�UHFRPPHQGHG��XVHU�DGMXVWDEOH�,QWHQVLW\�$GMXVWPHQWV Adjustable in 25% incrementsLED Life Expectancy (hours) >100,000
Electrical CharacteristicsCurrent Draw (mA) Refer to Sealite Power CalculatorCircuit Protection ,QWHJUDWHGNominal Voltage (v) 3.6Autonomy (days) >20 (14 hour darkness, 12.5% duty cycle)Temperature Range ����WR����&
Solar CharacteristicsSolar Module Type Multicrystalline2XWSXW��ZDWWV� 1.46RODU�0RGXOH�(I¿FLHQF\���� 14Charging Regulation Microprocessor controlled
Power SupplyBattery Type High grade NiMH - Environment friendlyBattery Capacity (Ah) 4Nominal Voltage (v) 3.6Battery Service Life Average 5 years
Physical CharacteristicsBody Material LEXAN® Polycarbonate - UV-stabilisedLens Material LEXAN® Polycarbonate - UV-stabilisedLens Diameter (mm/inches) 150 / 57/8
Lens Design ([WHUQDO�2SWLFV�ZLWK�LQWHULRU�ÀXWH�GHVLJQMounting 4 x 4.5mm mounting holesHeight (mm/inches) 205 / 81/8
Width (mm/inches) 177 / 7Mass (kg/lbs) 0.9 / 21/8 (SL60-LB 1 / 21/4. SL60/8Ah 1 / 21/4. SL60-LB/8Ah 1.1 / 21/2. SL60-LB/16Ah 1.5 / 31/3)Product Life Expectancy Up to 12 years
&HUWL¿FDWLRQVCE EN61000-6-3:1997. EN61000-6-1:1997Quality Assurance ,62���������Waterproof ,3��
Intellectual PropertyPatents US Pat. No. 6,667,582. AU Pat. No. 778,918Trademarks 6($/,7(��LV�D�UHJLVWHUHG�WUDGHPDUN�RI�6HDOLWH�3W\�/WG
Warranty * Full 3 years
Options Available ���$K�EDWWHU\��6/����$K�RU�6/���/%��$K��������$K�EDWWHU\��6/���/%���$K������PP�2'�EDVH��6/���/%��� ���������PP�SROH�PRXQW�DGDSWHU�SODWH
��6SHFL¿FDWLRQV�VXEMHFW�WR�FKDQJH�RU�YDULDWLRQ�ZLWKRXW�QRWLFH�������� �6XEMHFW�WR�VWDQGDUG�WHUPV�DQG�FRQGLWLRQV��������¨�,QWHQVLW\�VHWWLQJ�VXEMHFW�WR�VRODU�DYDLODELOLW\
Latest products and information available at www.sealite.com6
SL60 2-3nm+ Solar Marine Light
Charging the BatteryNew lanterns should be left in the sun for 1-2 days to ensure battery is charged before placing in service. Please note, lantern will re-charge even when toggle switch is turned to ‘OFF’ position.
Preferred Installation LocationFor best lantern performance, ensure solar modules are not covered and are in clear view of the sun with no shadows.
Lantern Operation/DQWHUQ�LV�DFWLYDWHG�E\�21�2))�6ZLWFK��,QWHQVLW\�DQG�ÀDVK�VHWWLQJV�QHHG�WR�EH�VHW�SULRU�WR�DFWLYDWLRQ����� 5HPRYH�WKH�PDUNHG�ÀDVK�DGMXVWPHQW�EXQJ�IURP�WKH�EDVH�RI�WKH�ODQWHUQ�DQG�VHW�LQWHUQDO�WRJJOH�
VZLWFK�WR�µ21¶���� 7KH�SRZHU�DQG�UDQJH�VHWWLQJV�RI�WKH�ODQWHUQ�DUH�DGMXVWHG�E\�VHWWLQJ�WKH�',3�VZLWFKHV�LQVLGH�WKH�
lantern. Your lantern is normally set to maximum range (see ‘Selecting an Intensity/Power Setting’ section of this manual).
��� 6HW�URWDU\�VZLWFKHV�WR�WKH�UHTXLUHG�ÀDVK�FRGH��VHH�‘Selecting a Flash Code’ section of this manual).
��� 5HSODFH�ÀDVK�DGMXVWPHQW�EXQJ��5. A sealed vent on the base allows air transfer without moisture intake, and should not be disturbed.6. To test place dark cover (towel or jacket) on top of light to activate sensor, light will come on.��� (QVXUH�WKDW�WKH�XQLW�LV�EROWHG�WR�DQ�HYHQ��ÀDW�VXUIDFH��
456 7
8 9 ABCD
EF0123
456 7
8 9 ABCD
EF0123
A
B
1
2
ON
ONRotary Switch B
Rotary Switch A
,QWHQVLW\�6HWWLQJ
FLASH
ADJUST
MENT
SEALED
VENT
21���2))�Switch
UserReplaceable
Battery
LanternBase
Installation
Latest products and information available at www.sealite.com7
SL60 2-3nm+ Solar Marine Light
3XOVH�VHWWLQJV�RQ�6HDOLWH�ODQWHUQV�RSHUDWH�YLD�',3�VZLWFKHV��ORFDWHG�QHDU�WKH�URWDU\�VZLWFKHV�RQ�WKH�ÀDVKHU�XQLW��7KH�SXOVH�VHWWLQJV�PD\�EH�XVHG�WR�UHGXFH�WKH�SRZHU�FRQVXPSWLRQ�DQG�LQWHQVLW\�RI�WKH�lantern. Setting the lantern to 25% pulse will reduce the power consumption to 25% of the normal 100% setting and the range by 50%. This setting may be used to adjust the current draw of the light to local sunlight conditions. The following diagrams indicate pulse settings:-
Power Consumption Calculator
If the number of Full Sunlight hours is greater than 3-3.5 hours, please consider reducing the intensity (Power) or reducing the Duty Cycle.
$OO�ODQWHUQV�KDYH���URWDU\�VZLWFKHV�PDUNHG�$�DQG�%�RQ�WKH�ÀDVKHU�XQLW��7XUQLQJ�WKH�VPDOO�DUURZV�WR�WKH�appropriate number or letter will set the code (see ‘Flash Codes’ section, of this manual). The unit may WDNH�XS�WR�RQH�PLQXWH�WR�DFWLYDWH�D�QHZ�ÀDVK�FRGH��$�FRPSUHKHQVLYH�OLVW�RI�DYDLODEOH�ÀDVK�FRGHV�LV�listed on pages in the ‘Flash Codes’ section of this manual.Example:
100%
1 2
ON
75%
1 2
ON
50%
1 2
ON
25%
1 2
ONIntensity Setting
PowermA / hour
100% 85mA75% 64mA50% 43mA25% 22mA
456 7
8 9 ABCD
EF0123
456 7
8 9 ABCD
EF0123 A
BSWITCH FLASH CODE ON OFFA BA 0 FL 3 S 0.3 2.7
Night Hours(use 13.7 if unknown)
PowermA/hour
Duty Cycle(e.g. 20% = 0.2)
Total power used per night
(mA)
X X =Total power
used per night(mA)
Solar Panel Charge
Number of Full Sunlight hours required to recharge battery
/ 176 =
Selecting an Intensity/Power Setting
Selecting a Flash Code - Rotary Switches A & B
Latest products and information available at www.sealite.com8
SL60 2-3nm+ Solar Marine Light
Flash Codes7KH��2N6/���PD\�EH�VHW�WR�DQ\�RI�����,$/$�UHFRPPHQGHG�ÀDVK�VHWWLQJV�ZKLFK�DUH�XVHU�DGMXVWDEOH�onsite without the need for external devices.
�FRGH�UHIHUHQFH�LV�OLVWHG�E\�QXPEHU�RI�ÀDVKHV
For the latest version of this document visit www.sealite.com, or email [email protected]
Symbols)/� )ODVK�IROORZHG�E\�QXPEHU�(J��)/���6��RQH�ÀDVK�HYHU\�VHFRQGF Fixed4� 4XLFN�ÀDVK94� 9HU\�TXLFN�ÀDVK2&� 2FFXOWLQJ��JUHDWHU�SHULRG�RQ�WKDQ�RII�,62� ,VRSKDVH��HTXDO�SHULRG�RQ�DQG�RII/)/�� /RQJ�ÀDVK�ORQJ02� 0RUVH�FRGH�����FRQWDLQV�OHWWHU
)RU�H[DPSOH��94�������/)/����6�PHDQV���YHU\�TXLFN�ÀDVKHV�IROORZHG�E\�D�ORQJ�ÀDVK��GXULQJ�D� 10-second interval.The amount of power your lantern draws through the night depends on the duty cycle, i.e. the amount of time on as a proportion to the timing cycle. For example, 0.5 seconds on and 4.5 seconds off equals a 10% duty cycle. ,W�LV�EHVW�WR�RSHUDWH�DW�WKH�ORZHVW�GXW\�F\FOH�DSSURSULDWH�WR�WKH�DFWXDO�QHHGV�RI�WKH�DSSOLFDWLRQ��
Recommended Rhythm for Flashing Light - IALA Regions A and B
MARK DESCRIPTION RHYTHMPort Hand & Starboard Marks: Any, other than Composite Group Flashing (2+1)
Preferred Channel Starboard: Composite Group Flashing (2+1)
Preferred Channel Port: Composite Group Flashing (2+1)
North Cardinal Mark: Very quick or quick
East Cardinal Mark: Very quick (3) every 5 seconds or quick (3) every 10 seconds
South Cardinal Mark: 9HU\�TXLFN�������ORQJ�ÀDVK�HYHU\����VHFRQGV�RU�TXLFN�������ORQJ�ÀDVK�HYHU\����VHFRQGV
West Cardinal Mark: Very quick (9) every 10 seconds or quick (9) every 15 seconds
Isolated Danger Mark: *URXS�ÀDVKLQJ����
Safe Water Mark: ,VRSKDVH��RFFXOWLQJ��RQH�ORQJ�ÀDVK�HYHU\����VHFRQGV�RU�0RUVH�&RGH�³$´
Special Marks: $Q\��RWKHU�WKDQ�WKRVH�GHVFULEHG�IRU�&DUGLQDO��,VRODWHG�'DQJHU�RU�6DIH�:DWHU�0DUNV
Latest products and information available at www.sealite.com9
SWITCH FLASH CODE ON OFFA B0 0 F (Steady light)D 3 VQ 0.5 S 0.2 0.3E 3 VQ 0.6 S 0.2 0.4F 3 VQ 0.6 S 0.3 0.37 3 Q 1 S 0.2 0.88 3 Q 1 S 0.3 0.79 3 Q 1 S 0.4 0.6A 3 Q 1 S 0.5 0.58 4 Q 1 S 0.8 0.2B 3 Q 1.2 S 0.3 0.99 4 Q 1.2 S 0.5 0.7C 3 Q 1.2 S 0.6 0.6F 4 FL 1.5 S 0.2 1.31 0 FL 1.5 S 0.3 1.20 5 FL 1.5 S 0.4 1.10 4 FL 1.5 S 0.5 1.02 0 FL 2 S 0.2 1.83 0 FL 2 S 0.3 1.74 0 FL 2 S 0.4 1.65 0 FL 2 S 0.5 1.56 0 FL 2 S 0.7 1.37 0 FL 2 S 0.8 1.21 2 ,62���6 1.0 1.08 0 FL 2.5 S 0.3 2.29 0 FL 2.5 S 0.5 2.0D 6 FL 2.5 S 1.0 1.51 5 FL 3 S 0.2 2.8A 0 FL 3 S 0.3 2.72 5 FL 3 S 0.4 2.6B 0 FL 3 S 0.5 2.53 5 FL 3 S 0.6 2.4C 0 FL 3 S 0.7 2.3D 0 FL 3 S 1.0 2.02 2 ,62���6 1.5 1.55 4 2&���6 2.0 1.0E 2 2&���6 2.5 0.54 6 2&�����6 2.5 1.04 5 FL 4 S 0.2 3.85 5 FL 4 S 0.3 3.7E 0 FL 4 S 0.4 3.6F 0 FL 4 S 0.5 3.56 5 FL 4 S 0.6 3.40 1 FL 4 S 0.8 3.21 1 FL 4 S 1.0 3.02 1 FL 4 S 1.5 2.53 2 ,62���6 2.0 2.03 6 2&���6 2.5 1.5F 2 2&���6 3.0 1.03 1 FL 4.3 S 1.3 3.08 5 FL 5 S 0.2 4.84 1 FL 5 S 0.3 4.75 1 FL 5 S 0.5 4.59 5 FL 5 S 0.9 4.16 1 FL 5 S 1.0 4.0
SWITCH FLASH CODE ON OFFA B7 1 FL 5 S 1.5 3.54 2 ,62���6 2.5 2.58 2 LFL 5 S 2.0 3.00 3 2&���6 3.0 2.01 3 2&���6 4.0 1.02 3 2&���6 4.5 0.5C 6 FL 6 S 0.2 5.8B 5 FL 6 S 0.3 5.7C 5 FL 6 S 0.4 5.68 1 FL 6 S 0.5 5.59 1 FL 6 S 0.6 5.4A 1 FL 6 S 1.0 5.07 5 FL 6 S 1.2 4.8B 1 FL 6 S 1.5 4.55 2 ,62���6 3.0 3.09 2 LFL 6 S 2.0 4.06 4 2&���6 4.0 2.03 3 2&���6 4.5 1.54 3 2&���6 5.0 1.0A 4 FL 7 S 1.0 6.09 6 FL 7 S 2.0 5.05 6 2&���6 4.5 2.5D 5 FL 7.5 S 0.5 7.0C 1 FL 7.5 S 0.8 6.7E 5 FL 8 S 0.5 7.5B 4 FL 8 S 1.0 7.06 2 ,62���6 4.0 4.0A 2 LFL 8 S 2.0 6.06 6 2&���6 5.0 3.0B 2 LFL 8 S 3.0 5.0F 5 FL 9 S 0.9 8.1C 4 FL 9 S 1.0 8.07 6 2&���6 6.0 3.00 6 FL 10 S 0.2 9.81 6 FL 10 S 0.3 9.7D 1 FL 10 S 0.5 9.52 6 FL 10 S 0.8 9.2E 1 FL 10 S 1.0 9.01 4 FL 10 S 1.5 8.5C 2 LFL 10 S 2.0 8.0D 2 LFL 10 S 3.0 7.07 2 ,62����6 5.0 5.02 4 LFL 10 S 4.0 6.08 6 2&����6 6.0 4.05 3 2&����6 7.0 3.06 3 2&����6 7.5 2.5F 1 FL 12 S 1.2 10.8D 4 FL 12 S 2.5 9.53 4 LFL 12 S 2.0 10.00 2 FL 15 S 1.0 14.04 4 LFL 15 S 4.0 11.07 4 2&����6 10 5.0A 6 LFL 20 S 2.0 18.0E 4 FL 26 S 1.0 25.0
Latest products and information available at www.sealite.com10
SL60 2-3nm+ Solar Marine Light
SWITCH FLASH CODE ON OFF ON OFFA B0 A FL (2) 4 S 0.5 1.0 0.5 2.0E B VQ (2) 4 S 0.2 1.0 0.2 2.61 A FL (2) 4.5 S 0.3 1.0 0.3 2.92 A FL (2) 4.5 S 0.4 1.0 0.4 2.73 A FL (2) 4.5 S 0.5 1.0 0.5 2.5F 9 FL (2) 5 S 0.2 0.8 0.2 3.82 C FL (2) 5 S 0.2 1.2 0.2 3.44 A FL (2) 5 S 0.4 0.6 0.4 3.60 7 FL (2) 5 S 0.5 1.0 0.5 3.01 7 FL (2) 5 S 1.0 1.0 1.0 2.09 B Q (2) 5 S 0.3 0.7 0.3 3.72 9 Q (2) 5 S 0.5 0.5 0.5 3.55 A FL (2) 5.5 S 0.4 1.4 0.4 3.37 8 FL (2) 6 S 0.3 0.6 1.0 4.1A A FL (2) 6 S 0.3 0.9 0.3 4.56 A FL (2) 6 S 0.3 1.0 0.3 4.47 A FL (2) 6 S 0.4 1.0 0.4 4.29 9 FL (2) 6 S 0.5 1.0 0.5 4.02 8 FL (2) 6 S 0.8 1.2 0.8 3.23 7 FL (2) 6 S 1.0 1.0 1.0 3.03 9 Q (2) 6 S 0.3 0.7 0.3 4.7A 9 FL (2) 7 S 1.0 1.0 1.0 4.07 B FL (2) 8 S 0.4 0.6 2.0 5.08 A FL (2) 8 S 0.4 1.0 0.4 6.24 7 FL (2) 8 S 0.5 1.0 0.5 6.08 8 FL (2) 8 S 0.8 1.2 2.4 3.65 7 FL (2) 8 S 1.0 1.0 1.0 5.04 C 2&�������6 3.0 2.0 1.0 2.05 C 2&�������6 5.0 1.0 1.0 1.0F B VQ (2) 8 S 0.2 1.0 0.2 6.69 A FL (2) 10 S 0.4 1.6 0.4 7.66 7 FL (2) 10 S 0.5 1.0 0.5 8.07 7 FL (2) 10 S 0.5 1.5 0.5 7.56 9 FL (2) 10 S 0.5 2.0 0.5 7.08 7 FL (2) 10 S 0.8 1.2 0.8 7.2B 9 FL (2) 10 S 1.0 1.0 1.0 7.09 7 FL (2) 10 S 1.0 1.5 1.0 6.54 9 Q (2) 10 S 0.6 0.4 0.6 8.4B A FL (2) 12 S 0.4 1.0 0.4 10.2C 9 FL (2) 12 S 0.5 1.0 0.5 10.0D 9 FL (2) 12 S 1.5 2.0 1.5 7.0A 8 FL (2) 15 S 0.5 1.5 2.0 11.0A 7 FL (2) 15 S 1.0 2.0 1.0 11.08 B Q (2) 15 S 0.2 0.8 0.2 13.8C A FL (2) 20 S 1.0 3.0 1.0 15.0D A FL (2) 25 S 1.0 1.0 1.0 22.0
SWITCH FLASH CODE ON OFF ON OFF ON OFFA B7 9 Q (3) 5 S 0.5 0.5 0.5 0.5 0.5 2.55 9 VQ (3) 5 S 0.2 0.3 0.2 0.3 0.2 3.80 C VQ (3) 5 S 0.3 0.2 0.3 0.2 0.3 3.7E 9 VQ (3) 5 S 0.3 0.3 0.3 0.3 0.3 3.53 C FL (3) 6 S 0.5 1.0 0.5 1.0 0.5 2.52 B FL (2+1) 6 S 0.3 0.4 0.3 1.2 0.3 3.5
Latest products and information available at www.sealite.com11
SL60 2-3nm+ Solar Marine Light
SWITCH FLASH CODE ON OFF ON OFF ON OFFA BA B Q (3) 6 S 0.3 0.7 0.3 0.7 0.3 3.7F A FL (3) 8 S 0.5 1.0 0.5 1.0 0.5 4.50 B FL (3) 9 S 0.3 1.0 0.3 1.0 0.3 6.1B 7 FL (3) 9 S 0.8 1.2 0.8 1.2 0.8 4.2B 8 FL (3) 10 S 0.3 0.7 0.3 0.7 0.9 7.1C 8 FL (3) 10 S 0.4 0.6 0.4 0.6 1.2 6.8C B FL (3) 10 S 0.5 0.5 0.5 0.5 0.5 7.5C 7 FL (3) 10 S 0.5 1.5 0.5 1.5 0.5 5.5D B FL (3) 10 S 0.6 0.6 0.6 0.6 0.6 7.0D 7 FL (3) 10 S 1.0 1.0 1.0 1.0 1.0 5.03 8 FL (2+1) 10 S 0.5 0.7 0.5 2.1 0.5 5.78 9 2&��������6 5.0 1.0 1.0 1.0 1.0 1.0B B Q (3) 10 S 0.3 0.7 0.3 0.7 0.3 7.7D 8 FL (2 + 1) 10 S 0.5 0.5 0.5 0.5 1.5 6.51 B FL (3) 12 S 0.5 1.5 0.5 1.5 0.5 7.5E A FL (3) 12 S 0.5 2.0 0.5 2.0 0.5 6.5E 7 FL (3) 12 S 0.8 1.2 0.8 1.2 0.8 7.2B 6 FL (3) 12 S 1.0 1.0 1.0 3.0 1.0 5.04 8 FL (2+1) 12 S 0.8 1.2 0.8 2.4 0.8 6.05 8 FL (2+1) 12 S 1.0 1.0 1.0 4.0 1.0 4.01 8 FL (2+1) 13.5 S 1.0 1.0 1.0 4.0 1.0 5.5F 7 FL (3) 15 S 0.3 1.7 0.3 1.7 0.3 10.79 D FL (3) 15 S 0.4 1.0 0.4 1.0 0.4 11.80 8 FL (3) 15 S 0.5 1.5 0.5 1.5 0.5 10.5F 8 FL (2+1) 15 S 0.6 0.3 0.6 0.3 1.4 11.80 9 FL (2+1) 15 S 0.7 0.5 0.7 0.5 1.9 10.71 9 FL (2+1) 15 S 0.7 0.7 0.7 0.7 2.1 10.16 8 FL (2+1) 15 S 1.0 2.0 1.0 5.0 1.0 5.01 C VQ (3) 15 S 0.1 0.5 0.1 0.5 0.1 13.74 B FL (3) 20 S 0.5 3.0 0.5 3.0 0.5 12.53 B FL (3) 20 S 0.5 1.5 0.5 1.5 0.5 15.55 B FL (3) 20 S 0.8 1.2 0.8 1.2 0.8 15.26 B FL (3) 20 S 1.0 1.0 1.0 1.0 1.0 15.0
SWITCH FLASH CODE ON OFF ON OFF ON OFF ON OFFA BB F VQ (4) 4 S 0.3 0.3 0.3 0.3 0.3 0.3 0.3 2.3B D Q (4) 6 S 0.3 0.7 0.3 0.7 0.3 0.7 0.3 2.78 D Q (4) 6 S 0.4 0.6 0.4 0.6 0.4 0.6 0.4 2.61 D FL (4) 10 S 0.5 1.0 0.5 1.0 0.5 1.0 0.5 5.02 D FL (4) 10 S 0.8 1.2 0.8 1.2 0.8 1.2 0.8 3.2F E Q (4) 10 S 0.3 0.7 0.3 0.7 0.3 0.7 0.3 6.7B E FL (4) 12 S 0.3 1.7 0.3 1.7 0.3 1.7 0.3 5.74 F FL (4) 12 S 0.5 0.5 0.5 0.5 0.5 0.5 0.5 8.5C E FL (4) 12 S 0.5 1.5 0.5 1.5 0.5 1.5 0.5 5.53 D FL (4) 12 S 0.8 1.2 0.8 1.2 0.8 1.2 0.8 5.2A D Q (4) 12 S 0.3 0.7 0.3 0.7 0.3 0.7 0.3 8.74 D FL (4) 15 S 0.5 1.5 0.5 1.5 0.5 1.5 0.5 8.58 E FL (4) 15 S 1.0 1.0 1.0 1.0 1.0 1.0 1.0 8.07 D FL (4) 15 S 1.5 0.5 0.5 0.5 0.5 0.5 0.5 10.5D E FL (4) 16 S 0.5 1.5 0.5 1.5 0.5 1.5 0.5 9.5C D FL (4) 20 S 0.3 3.0 0.3 3.0 0.3 3.0 0.3 9.85 D FL (4) 20 S 0.5 1.5 0.5 1.5 0.5 1.5 0.5 13.50 D FL (4) 20 S 0.5 1.5 0.5 1.5 0.5 4.5 0.5 10.53 F FL (4) 20 S 1.5 1.5 1.5 1.5 1.5 1.5 1.5 9.50 F Q (4) 20 S 0.5 0.5 0.5 0.5 0.5 0.5 0.5 16.5E E Q (4) 28 S 0.5 0.5 0.5 0.5 0.5 0.5 0.5 24.56 F FL (4) 30 S 0.5 0.5 0.5 0.5 0.5 0.5 0.5 26.5
Latest products and information available at www.sealite.com12
SL60 2-3nm+ Solar Marine Light
SWITCH FLASH CODE ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFFA B4 E VQ (9) 10 S 0.2 0.3 0.2 0.3 0.2 0.3 0.2 0.3 0.2 0.3 0.2 0.3 0.2 0.3 0.2 0.3 0.2 5.85 E VQ (9) 10 S 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 4.91 F Q (9) 15 S 0.2 0.8 0.2 0.8 0.2 0.8 0.2 0.8 0.2 0.8 0.2 0.8 0.2 0.8 0.2 0.8 0.2 6.80 E Q (9) 15 S 0.3 0.7 0.3 0.7 0.3 0.7 0.3 0.7 0.3 0.7 0.3 0.7 0.3 0.7 0.3 0.7 0.3 6.71 E Q (9) 15 S 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 4.8
SWITCH FLASH CODE ON OFF ON OFF ON OFF ON OFFA B0256(�&2'(�������,1',&$7(6�/(77(57 8 02��$����6 0.3 0.6 1.0 4.17 B 02��$����6 0.4 0.6 2.0 5.08 8 02��$����6 0.8 1.2 2.4 3.6B 8 02��8�����6 0.3 0.7 0.3 0.7 0.9 7.1C 8 02��8�����6 0.4 0.6 0.4 0.6 1.2 6.8D 8 02��8�����6 0.5 0.5 0.5 0.5 1.5 6.59 8 02��$�����6 0.5 0.5 1.5 7.58 9 02��'�����6 5.0 1.0 1.0 1.0 1.0 1.0A 8 02��$�����6 0.5 1.5 2.0 11.0F 8 02��8�����6 0.6 0.3 0.6 0.3 1.4 11.80 9 02��8�����6 0.7 0.5 0.7 0.5 1.9 10.71 9 02��8�����6 0.7 0.7 0.7 0.7 2.1 10.17 D 02��%�����6 1.5 0.5 0.5 0.5 0.5 0.5 0.5 10.5
SWITCH FLASH CODE ON OFF ON OFF ON OFF ON OFF ON OFFA BD D Q (5) 7 S 0.3 0.7 0.3 0.7 0.3 0.7 0.3 0.7 0.3 2.7E D Q (5) 10 S 0.3 0.7 0.3 0.7 0.3 0.7 0.3 0.7 0.3 5.7E 8 FL (5) 12 S 0.5 1.5 0.5 1.5 0.5 1.5 0.5 1.5 0.5 3.55 F FL (5) 20 S 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 15.59 F FL (5) 20 S 0.8 1.2 0.8 1.2 0.8 1.2 0.8 1.2 0.8 11.29 E FL (5) 20 S 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 11.0
SWITCH FLASH CODE ON OFF ON OFF ON OFF ON OFF ON OFF ON OFFA BF D Q (6) 10 S 0.3 0.7 0.3 0.7 0.3 0.7 0.3 0.7 0.3 0.7 0.3 4.7A F FL (6) 15 S 0.3 0.7 0.3 0.7 0.3 0.7 0.3 0.7 0.3 0.7 0.3 9.77 F FL (6) 15 S 0.5 1.0 0.5 1.0 0.5 1.0 0.5 1.0 0.5 1.0 0.5 7.0A E FL (6) + LFL 15 S 0.5 1.0 0.5 1.0 0.5 1.0 0.5 1.0 0.5 1.0 0.5 7.0
SWITCH FLASH CODE ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFFA B6 E VQ (6) + LFL 10 S 0.2 0.3 0.2 0.3 0.2 0.3 0.2 0.3 0.2 0.3 0.2 0.3 2.0 5.07 E VQ (6) + LFL 10 S 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 2.0 4.42 F Q (6) + LFL 15 S 0.2 0.8 0.2 0.8 0.2 0.8 0.2 0.8 0.2 0.8 0.2 0.8 2.0 7.02 E Q (6) + LFL 15 S 0.3 0.7 0.3 0.7 0.3 0.7 0.3 0.7 0.3 0.7 0.3 0.7 2.0 7.03 E Q (6) + LFL 15 S 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 2.0 5.88 F VQ (6) + LFL 15 S 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 2.0 9.4
Latest products and information available at www.sealite.com13
SL60 2-3nm+ Solar Marine Light
Maintenance and ServicingDesigned to be maintenance free, the 2NSL60 requires minimal attention, though the following maintenance and servicing information is provided to help ensure the life of your Sealite product. 1. Cleaning Solar Panels - occasional cleaning of the solar panels may be required. Using a cloth and
warm soapy water, wipe off any foreign matter before rinsing the panels with fresh water. 2. Battery Check - inspection of batteries should be performed every three years (minimum) to ensure
that the charger, battery and ancillary electronics are functioning correctly. Using a voltage meter, check that the battery voltage is at least 3.6 volts under 100MA load, and ensure all terminals are clear of foreign matter.
Replacing the battery- Don’t throw the unit out!! The 2NSL60 lanterns are the only compact marine lantern with a double sealed battery compartment. This provides the user with the ability to change the battery after years of operation.��� 5HPRYH�WKH�PDUNHG�ÀDVK�DGMXVWPHQW�EXQJ�IURP�WKH�EDVH�RI�WKH�ODQWHUQ�DQG�VHW�LQWHUQDO�WRJJOH�
VZLWFK�WR�µ2))¶�2. Unscrew small screws to remove battery plate. 3. Remove battery from 2NSL60 case and unscrew positive and negative leads. 4. Discard old battery in a safe manner. 5. Reattach positive and negative leads to new battery and then place back into case. ��� 5HDWWDFK�EDWWHU\�SODWH�DQG�VZLWFK�ODQWHUQ�µ21¶�YLD�LQWHUQDO�VZLWFK��&ORVH�WKH�EXQJ�7. To test place dark cover (towel or jacket) on top of light to activate sensor, light will come on.Care must be taken to observe the polarity of the battery before the leads are re-connected, and HQVXUH�WKH�UHSODFHPHQW�EDWWHU\�LV�FRUUHFWO\�¿WWHG��$OZD\V�GLVFDUG�ROG�EDWWHULHV�LQ�D�VDIH�PDQQHU��
Long Term Storage Instructions,I�WKH�6/���LV�WR�EH�SODFHG�LQ�VWRUDJH�IRU�DQ�H[WHQGHG�SHULRG��EHLQJ�PRUH�WKDQ���PRQWKV��SOHDVH�IROORZ�the below steps.1. The 3.6V NiMH Battery must be stored in a fully charged condition.��� 5HPRYH�WKH�)ODVK�$GMXVWPHQW�SOXJ�DQG�WXUQ�WKH�21�2))�VZLWFK�WR�WKH�2))�SRVLWLRQ�3. Remove the battery cover and disconnect the Positive (+) Terminal.4. Fold the Terminal away from the Negative Battery Terminal. 5. Replace the Battery Cover6. Replace the Flash Adjustment Plug.$OO�EDWWHULHV�ZLOO�GLVFKDUJH�RYHU�WLPH�DQG�WKH�UDWH�RI�GLVFKDUJH�LV�GHSHQGHQW�RQ�WHPSHUDWXUH��,I�WKH�OLJKW�LV�being stored in temperatures greater than 40°C the battery will discharge faster.Please check battery every 3-6 months and recharge if necessary.
Recharging the Battery1. Remove the Battery Cover and connect the Positive Terminal.��� 5HPRYH�WKH�)ODVK�$GMXVWPHQW�3OXJ�DQG�WXUQ�WKH�21�2))�VZLWFK�WR�WKH�21�SRVLWLRQ�3. Reconnect the battery and place unit in the sun for 2-4 days2UReconnect battery and place in front of a halogen lamp for 2-3 days. (Do not place the halogen light too close to the solar panel or the panel may be overheated)
Check the battery voltage regularly to make sure the unit is charging correctly.$IWHU�WKH�EDWWHU\�KDV�EHHQ�UHFKDUJHG��VZLWFK�WKH�OLJKW�2))�
Latest products and information available at www.sealite.com14
SL60 2-3nm+ Solar Marine Light
Trouble Shooting
Problem RemedyLantern will not activate. �� (QVXUH�LQWHUQDO�WRJJOH�VZLWFK�LV�VHW�WR�WKH�µ21�SRVLWLRQ�
�� (QVXUH�ODQWHUQ�LV�LQ�GDUNQHVV��� :DLW�DW�OHDVW����VHFRQGV�IRU�WKH�SURJUDP�WR�LQLWLDOLVH�LQ�GDUNQHVV��� (QVXUH�VZLWFK�VHWWLQJ�LV�RQ�D�YDOLG�FRGH��6HH�Flash Codes section of this
manual).�� (QVXUH�EDWWHU\�WHUPLQDOV�DUH�SURSHUO\�FRQQHFWHG��� (QVXUH�EDWWHU\�YROWDJH�LV�DERYH����YROWV�
Timing codes will not change. �� 7XUQ�URWDU\�VZLWFKHV�VHYHUDO�WLPHV�WR�HQVXUH�FRQWDFWV�DUH�FOHDU�
Lantern will not operate for the entire night.
�� ([SRVH�ODQWHUQ�WR�GLUHFW�VXQOLJKW�DQG�PRQLWRU�RSHUDWLRQ�IRU�VHYHUDO�GD\V��Sealite products typically require 1.5 hours of direct sunlight per day to retain full autonomy. From a discharged state, the lantern may require several days of operational conditions to ‘cycle’ up to full autonomy.
�� 5HGXFLQJ�WKH�OLJKW�RXWSXW�LQWHQVLW\�RU�GXW\�F\FOH��ÀDVK�FRGH��ZLOO�UHGXFH�current draw on the battery.
�� (QVXUH�VRODU�PRGXOH�LV�FOHDQ�DQG�QRW�FRYHUHG�E\�VKDGLQJ�GXULQJ�WKH�GD\�
Lantern is constantly on during the day.
�� (QVXUH�WKH�ÀDVK�FRGH�LV�QRW�VHW�WR�)�)��7KLV�ÀDVK�FRGH�LV�IRU�WHVWLQJ�purposes only and will be steady on for 24 hours a day.
Latest products and information available at www.sealite.com15
SL60 2-3nm+ Solar Marine Light
2N6/���2SWLRQDO�&RQ¿JXUDWLRQV200mm OD Base (2NSL60-LB)$YDLODEOH�ZLWK�ODUJHU����PP�2'�EDVH�SDWWHUQ�IRU�LPPHGLDWH�LQVWDOODWLRQ�RQ�H[LVWLQJ�VWUXFWXUHV�
8Ah Battery (2NSL60/8Ah) or 16Ah Battery (2NSL60-LB/16Ah)Avaialble with 8Ah battery for low sunlight regions, or high duty cycles.