1F87-361Programmable Electronic Digital Thermostat
INSTALLATION ANDOPERATION INSTRUCTIONS
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE.
DESCRIPTION• Temperatureoverrideuntilnextprogramperiod• Manualprogramoverride(HOLDtemperature)• TemporaryHOLD• °F/°Cconvertibility• Temperaturerange45°to90°F• RC,RH,C,W,Y,G,OandBterminals• OptionalCterminal(DualPoweroption)• BandOterminalsforsinglestageheatpumps(noauxiliary
heat)ordamperoperation• Programstorageincaseofpowerloss• 2“AA”Energizer®alkalinebatteriesincluded
Operator: Save these instructions for future use!
Your new White-Rodgers 7-Day DigitalThermostat uses thetechnologyofasolid-statemicrocomputer toprovideprecisetime/temperaturecontrol.Thisthermostatoffersyoutheflexibilitytodesignheatingandcoolingprogramsthatfityourneeds.
Features:• Separateprogramforeachdayoftheweekwithfourseparate
time/temperatureperiodsperday• Simultaneousheatandcoolprogramstorage• Preprogrammedtemperaturecontrol• Backlitdisplay• LCDcontinuouslydisplayssetpoint,andalternatelydisplays
timeandroomtemperature
PRECAUTIONSThisthermostatisintendedforusewithalowvoltagesystem;donotusethisthermostatwithalinevoltagesystem.Ifindoubtaboutwhetheryourwiringismillivolt,line,orlowvoltage,haveitinspectedbyaqualifiedheatingandairconditioningcontractororelectrician.
Donotexceedthespecificationratings.
Allwiringmustconformto localandnationalelectricalcodesandordinances.
Thiscontrolisaprecisioninstrument,andshouldbehandledcarefully.Roughhandlingordistortingcomponentscouldcausethecontroltomalfunction.
▲! CAUTIONTo prevent electrical shock and/or equipment damage, disconnect electric power to system at main fuse or circuit breaker box until installation is complete.
▲! WARNINGDo not use on circuits exceeding specified voltage. Higher voltage will damage control and could cause shock or fire hazard.
Do not short out terminals on gas valve or primary control to test. Short or incorrect wiring will damage thermostat and could cause personal injury and/or property damage.
Thermostat installation and all components of the system shall conform to Class II circuits per the NEC code.
SPECIFICATIONSELECTRICAL DATA
Electrical Rating: 8to30VAC50/60Hz.orD.C. 0.05to1.0Amps(Loadperterminal) 1.5 Amps Maximum Total Load(Allterminalscombined)
THERMAL DATA
Setpoint Temperature Range: 45°Fto90°F(7°Cto32°C)Operating Ambient Temperature Range: 32°Fto105°FOperating Humidity Range: 0to90%RH(non-condensing)Shipping Temperature Range: -4°Fto149°F
APPLICATIONS
Forusewith:• Standardheat/coolorheatonlysystems• Electricheatsystems• Gasoroilfiredsystems• Gassystemswithintermittentignitiondevices(I.I.D.) and/orventdampers• Hydronic(hotwaterorsteam)systems• Single-stageheatpumpsystems(noauxiliaryheat)• Millivoltsystems
DO NOT USE WITH:• Multi-stagesystems• Systemsexceeding30VACand1.5amps• 3-wirezonedhydronicheatingsystems
PART NO. 37-6763BReplaces37-6763A
1006www.white-rodgers.com
2
Mountingholes
Mountingholes
Electric/Gasswitch
Screw anchors
INSTALLATION
REMOVE OLD THERMOSTAT1. Shutoffelectricityatthemainfuseboxuntilinstallationis
complete.Ensurethatelectricalpowerisdisconnected.2. Removethefrontcoveroftheoldthermostat.With wires
still attached, removewallplate from thewall. If theoldthermostathasawallmountingplate,removethethermostatandthewallmountingplateasanassembly.
3. Identify each wire attached to the old thermostat using the labels enclosed with the new thermostat.
4. Disconnectthewiresfromoldthermostatoneatatime.DO NOT LET WIRES FALL BACK INTO THE WALL.
5. Installnewthermostatusingthefollowingprocedures.
ATTENTION!Thisproductdoesnotcontainmercury.However,thisproductmayreplaceaunitwhichcontainsmercury.
Donotopenmercurycells.Ifacellbecomesdamaged,donottouchanyspilledmercury.Wearingnonabsorbentgloves,takeupthespilledmercurywithsandorotherabsorbentmaterialandplaceintoacontainerwhichcanbesealed.Ifacellbecomesdamaged,theunitshouldbediscarded.
Mercurymustnotbediscardedinhouseholdtrash.Whentheunitthisproductisreplacingistobediscarded,placeinasuit-ablecontainer.Refertowww.white-rodgers.comforlocationtosendproductcontainingmercury.
ELECTRIC HEAT OR SINGLE-STAGE HEAT PUMP SYSTEMS
Thisthermostatisconfiguredfromthefactorytooperateaheat/cool,fossilfuel(gas,oil,etc.),forcedairsystem.ItisconfiguredcorrectlyforanysystemthatDOESNOTrequirethethermostattoenergizethefanonacallforheat.Ifyoursystemisanelectricheatorheat-pumpsystemthatREQUIRESthethermostattoturnonthefanonacallforheat,locatetheELECTRIC/GAS switch onthebackof the thermostat (seefig.1)andswitchit to the ELECTRIC position. This will allow the thermostattoenergize thefan immediatelyonacall forheat. Ifyouareunsureiftheheating/coolingsystemrequiresthethermostattocontrolthefan,contactaqualifiedheatingandairconditioningserviceperson.
ATTACH THERMOSTAT BASE TO WALL1. Removethepackingmaterialfromthethermostat.Gently
pullthecoverstraightoffthebase.Forcingorpryingonthethermostatwillcausedamagetotheunit.Ifnecessary,movetheelectricheatswitch(seeELECTRIC HEAT SYSTEMS, above).
2. Connectwiresbeneathterminalscrewsonbaseusingap-propriatewiringschematic(seefigs.2through7).
3. Placebaseoverholeinwallandmarkmountingholeloca-tionsonwallusingbaseasatemplate.
4. Movebaseoutoftheway.Drillmountingholes.5. Fastenbaselooselytowall,asshowninfig.1,usingtwo
mounting screws. Place a level against bottom of base,adjustuntil level,andthentightenscrews.(Levelingisforappearanceonlyandwillnotaffectthermostatoperation.)Ifyouareusingexistingmountingholes,orifholesdrilledaretoolargeanddonotallowyoutotightenbasesnugly,useplasticscrewanchorstosecuresubbase.
6. Pushexcesswireintowallandplugholewithafire-resistantmaterial(suchasfiberglassinsulation)topreventdraftsfromaffectingthermostatoperation.
BATTERY LOCATION2“AA”alkalinebatteriesareincludedinthethermostatatthefactorywithabatterytagtopreventpowerdrainage.You must remove the battery tag to engage the batteries.
If“BATT”or“CHANGE ” isdisplayed,thebatteriesarelowandshouldbereplacedwithfresh“AA”Energizer®alkalinebatteries.Toreplacebatteries,installthebatteriesalongthetopofthebase(seeFig.1).Thebatteriesmustbeinstalledwiththepositive(+)endtotheleft.
HYDRONIC (HOT WATER OR STEAM) HEATING SYSTEMS
Thisthermostatissettooperateproperlywithaforced-airheat-ingsystem.Ifyouhaveahydronicheatingsystem(asystemthatheatswithhotwaterorsteam),youmustsetthethermostattooperateproperlywithyoursystem.Changethesecondop-tion in theconfigurationmenu toSL(seeCONFIGURATIONMENU,page4).
CHECK THERMOSTAT OPERATIONIf at any time during testing your system does not operateproperly,contactaqualifiedserviceperson.
Turnonpowertothesystem.
Fan OperationIfyoursystemdoes nothaveaGterminalconnection,skiptoHeating System.
1. MoveFANswitchtoON position.Theblowershouldbegintooperate.
2. Move FAN switch to AUTO position. The blower shouldstopimmediately.
Figure 1. Thermostat Base
3
RHY
24 VAC 120 VAC
Hot
Neutral
TRANSFORMER
THERMOSTAT
SYSTEMG W
Figure 3. Typical wiring diagram forcool only, 3-wire, single transformer systems
CoolingSystem
FanRelay
RCOBC‡
JUMPERWIRE
Figure 2. Typical wiring diagram forheat only, 3-wire, single transformer systems
RHY
24 VAC 120 VAC
Hot
Neutral
THERMOSTAT
SYSTEMG W
TRANSFORMER
HeatingSystem
FanRelay
RC
JUMPERWIRE
OC‡ B
For 2-wire Heat only, attach to RH and W
NOTE
RHY
24 VAC 120 VAC
Hot
Neutral
THERMOSTAT
SYSTEMG W
Figure 5. Typical wiring diagram forheat/cool, 5-wire, two-transformer systems
HEATINGTRANSFORMER
HeatingSystem
FanRelay
CoolingSystem
RC
24 VAC 120 VAC
Hot
Neutral
COOLING TRANSFORMER
OBC‡
RHY
24 VAC 120 VAC
Hot
Neutral
THERMOSTAT
SYSTEMG W
Figure 7. Typical wiring diagram for heat pumpwith reversing valve energized in HEAT
TRANSFORMER
ReversingValve*
RCOBC‡
JUMPERWIRE
CompressorContactor
JUMPERWIRE
* Reversing valve is energized when the system switch is in the HEAT position
FanRelay
‡ The24VoltneutralconnectiontoterminalConthethermostatisnotrequiredifthebatteriesarereplacedonceayearwithfresh“AA”Energizer®alkalinebatteries.
Heating System1. MoveSYSTEMswitchtoHEATposition.Iftheheatingsystem
hasastandingpilot,besuretolightit.
2. Press toadjustthermostatsettingaboveroomtempera-ture.Theheatingsystemshouldbegintooperate.
3. Press toadjustthermostatsettingbelowroomtempera-ture.Theheatingsystemshouldstopoperating.
To prevent compressor and/or property damage, if the outdoor temperature is below 50°F, DO NOT operate the cooling system.
1. MoveSYSTEMswitchtoCOOLposition.
2. Press toadjustthermostatsettingbelowroomtempera-ture.Theblowershouldcomeonimmediatelyonhighspeed,followedbycoldaircirculation
3. Press toadjustthermostatsettingaboveroomtempera-ture.Thecoolingsystemshouldstopoperating.
Cooling System
▲! CAUTION
INSTALLATION
RHY
24 VAC 120 VAC
Hot
Neutral
THERMOSTAT
SYSTEMG W
Figure 4. Typical wiring diagram forheat/cool, 4-wire, single transformer systems
TRANSFORMER
HeatingSystem
FanRelay
CoolingSystem
RC
JUMPERWIRE
OC‡ B
RED jumper wire (provided with thermostat) must be connected between thermostat RH and RC terminals for proper thermostat operation with this system.
NOTE
RHY
24 VAC 120 VAC
Hot
Neutral
THERMOSTAT
SYSTEMG W
Figure 6. Typical wiring diagram for heat pumpwith reversing valve energized in COOL
TRANSFORMER
ReversingValve*
RCOBC‡
JUMPERWIRE
CompressorContactor
JUMPERWIRE
* Reversing valve is energized when the system switch is in the COOL position
FanRelay
4
Before you begin programming your thermostat, you shouldbefamiliarwithitsfeaturesandwiththedisplayandtheloca-tionandoperationofthethermostatbuttons.Yourthermostatconsistsoftwoparts:thethermostat coverandthebase.Toremovethecover,pullitstraightoutfromthebase.Toreplacethecover,lineupthecoverwiththebaseandpressuntilthecoversnapsontothebase.
The Thermostat Buttons and Switches1 Raisestemperaturesetting.
2 Lowerstemperaturesetting.
3 TIMEbutton.
4 PRGM(program)button.
5 RUN(runprogram)button.
6 HOLDtemperaturebutton.
7 FANswitch(ON,AUTO).
8 SYSTEMswitch(COOL,OFF,HEAT).
The Display9 Indicatesdayoftheweek.
10 Flame icon ( ) is displayed when the SYSTEM switchisintheHEATposition.Snowflake icon( )isdisplayed(non-flashing)whentheSYSTEMswitchisintheCOOLposition.Snowflakeisdisplayed(flashing)ifthethermostatisinlockoutmodetopreventthecompressorfromcyclingtooquickly.
11 Displays “BATT” or “CHANGE ” when the 2 “AA”batteriesarelowandshouldbereplaced.Only“BATT” or“CHANGE ”and“LO”intheminutesfieldaredisplayedwhenbatteriesarelowwithnosystempower.
12 Alternatelydisplayscurrenttimeandtemperature.Displays“LO”intheminutesfieldwhenbatteriesarelow.
13 Theword“HOLD”isdisplayedwhenthethermostatisintheHOLDmode.“HOLD”isdisplayedflashingwhenthethermostatisinatemporaryHOLDMode.
14 Displays currently programmed set temperature (this isblankwhenSYSTEMswitchisintheOFFposition).
15 Displays “FLTR” when the system has run for the pro-grammedfiltertimeperiodasaremindertochangeorcleanyourairfilter.
CONFIGURATION MENUTheconfigurationmenuallowsyou tosetcertain thermostatoperatingcharacteristics toyoursystemorpersonal require-ments.
PressRUNtomakesurethethermostatisintherunprogrammode,thenpressPRGMandRUNatthesametimetoentertheconfigurationmenu.Thedisplaywillshowthefirstitemintheconfigurationmenu.
The configuration menu table summarizes the configurationoptions.Anexplanationofeachoptionfollows.
OPERATION
PressHOLDtochangetothenextmenuitemorpressTIMEtogobackwardstothepreviousiteminthemenu.Toexitthemenuandreturntotheprogramoperation,pressRUN.Ifnokeysarepressedwithinfifteenminutes,thethermostatwillreverttonormaloperation.
1) Select Temporary Hold Time -Thethermostatcanholdanytemperatureyousetittofortheamountoftimeyouselectonthisoption.Yourchoicesare0:00to8:00hoursin15minuteincrements.0:00disablesthefunction
Example:
1. Youhaveselected3:00hoursfortheTemporaryHoldtimeperiod.
2. WiththethermostatsettoHeatorCool,pressHOLDfor approximately five secondsuntilHOLDtime(3:00indicating3hours)appearsasasettingreminder.
3. Afterreleasingthebutton,“HOLD”onthedisplaywillblink.
4. Use or tosetthetemperaturetoyourprefer-ence. The thermostat will maintain this temperaturesettingfor3hourswith“HOLD”blinkingtoremindyouitisinTemporaryHold.After3hoursthethermostatwillgobacktotheprogramtemperatureand“HOLD”willnolongerblinkordisplay.
2) Select FA or SL (Fast or Slow) Heating Cycle Rate-TheFAsettingisfrequentlyusedforgas,oilorelectricheat.TheSLsettingproducesalongerheatingcyclewhichisnormallyfor hot water or steam (hydronic) systems. Both settingsproduceveryaccuratetemperaturecontrolandcanbesettoyourpersonalpreference.FAcyclesthesystemjustunder1°FandtheSLsettingcyclesatapproximately1.5°F.
3) Select backlit display - The display backlight improvesdisplaycontrastinlowlightingconditions.SelectingbacklightONwillkeepthelightonforashortperiodoftimeafteranykeyispressed.SelectingOFFwillkeepthelightoff.
CHANGE
5
4) Select Energy Management Recovery OFF or ON –EnergyManagementRecovery(EMR)causesthethermostattostartheatingorcoolingearlytomakethebuildingtem-peraturereachtheprogramsetpointatthetimeyouspecify.Heatingwillstart5minutesearlyforevery1°oftemperaturerequired to reach setpoint. Cooling allows more time perdegreebecauseittakeslongertoreachtemperature.
Example:YouselectEMRandhaveyourheatingprogrammedto65°atnightand70°at7AM.Ifthebuildingtemperatureis65°thedifferencebetween65°and70°is5°.Allowing5minutesperdegreethethermostatsetpointwillchangeto70°at6:35AM.
5) Select filter replacement run time -Thethermostatwilldisplay“FLTR” afterasettimeofoperation.Thisisaremindertochangeorcleanyourairfilter.Thistimecanbesetfrom0to1950hoursin50hourincrements.A selection of 000 will cancel this feature.When“FLTR” isdisplayed,youcanclearitbypressingHOLDandRUNatthesametime.Thisresetsthetimerandstartscountingthehoursuntilthenextfilterchange.Changingthetimeinthemenualsoresetsthetimer.
6) Select Compressor Lockout LOC OFF or ON-SelectingLOCONwillcausethethermostattowait5minutesbeforeturningonthecompressoriftheheatingandcoolingsystemlosespower.Itwillalsowait5minutesminimumbetweencoolingcycles.Thisisintendedtohelpprotectthecompres-sorfromshortcycling.Somenewercompressorsalreadyhavea timedelaybuilt inanddonot require this feature.Yourcompressormanufacturercantellyouifthefeatureisalreadypresentintheirsystem.Whenthecompressortimedelayoccursitwillflashthe(snowflakeicon)foraboutfiveminutesthenturnonthecompressor.
7) Select Temperature Display Adjustment 4 LO to 4 HI-Al-lowsyoutoadjusttheroomtemperaturedisplay4°higherorlower.Yourthermostatwasaccuratelycalibratedatthefactorybutyouhavetheoptiontochangethedisplaytemperaturetomatchyourpreviousthermostat.
8) Select F° or C° Readout-ChangesthedisplayreadouttoCentigradeorFahrenheitasrequired.
OPERATING FEATURESNowthatyouarefamiliarwiththethermostatbuttonsanddisplay,readthefollowinginformationtolearnaboutthemanyfeaturesofthethermostat.
• SIMULTANEOUS HEATING/COOLING PROGRAM STOR-AGE — When programming, you can enter both yourheatingandcoolingprogramsatthesametime.Thereisnoneedtoreprogramthethermostatatthebeginningofeachseason.
• TEMPERATURE OVERRIDE—Press or untilthedisplayshowsthetemperatureyouwant.Thethermostatwilloverridecurrentprogrammingandkeeptheroomtem-peratureattheselectedtemperatureuntilthenextprogramperiodbegins.Thenthethermostatwillautomaticallyreverttotheprogram.
• HOLD TEMPERATURE—Thethermostatcanholdanytemperaturewithinitsrangeforanindefiniteperiodwithoutrevertingtotheprogrammedtemperature.MomentarilypressHOLDbutton.“HOLD”willbedisplayed.Thenchoosethedesiredtemperaturebypressing or .ThethermostatwillholdtheroomtemperatureattheselectedsettinguntilyoupressRUNbuttontostartprogramoperationagain.
• CONFIGURATION MENU — Allows you to customizecertainthermostatoptions.
PROGRAMMING YOUR THERMOSTATThissectionwill helpyouplanyour thermostat’sprogram tomeetyourneeds.Formaximumcomfortandefficiency,keepthefollowingguidelinesinmindwhenplanningyourprogram.
• When heating (cooling) your building, program the temperaturestobecooler(warmer)whenthebuildingis vacantorduringperiodsoflowactivity.
• During early morning hours, the need for cooling is usuallyminimal.
1
Step Press Button(s) Displayed (Factory Default) Press or to select: COMMENTS
HOLD(0:00)
0 to 8 hrs (in 15 minute increments)
2(FA)
SL
Select temporary Hold time
4
5
E(ON)
OFF
6
7
LOC(OFF)
ON
0 HI(0)
4 LO to4 HI
(F) C
Returns to normal operation
8
9
Select Energy Management Recovery OFF or ON
Select compressor lockout OFF or ON
Select temperature display adjustment higher or lower
Select temperature display to F or C
RUN
PRGMand RUN
HOLD*
HOLD*
3 d-L(ON)
OFF Select display backlight OFF or ONHOLD*
HOLD*
Filter(000)
0 to 1950 hours(in 50 hour increments)
Select filter replacement run timeHOLD*
HOLD*
HOLD*
Select FA or SL (Fast or Slow) heating cycle rate
Configuration Menu
* Press HOLD to advance to next item or TIME to move backwards to previous item
OPERATION
6
Enter Heating Program1. MovetheSYSTEMswitchtoHEAT.2. Press PRGM once. “MO” (indicating Monday program)
willappearinthedisplay.Alsodisplayedarethecurrentlyprogrammedstarttimeforthe1st heatingperiodandthecurrentlyprogrammedtemperature(flashing).
EXAMPLE:
AM
MO
Thisdisplaywindowshows that forMonday’s1stheatingperiod,thestarttimeis6:00AM,and70°istheprogrammedtemperature (this example reflects factory preprogram-ming).
3. Press or tochangethedisplayedtemperaturetoyourselectedtemperatureforMonday’s1stheatingprogramperiod.
4. PressTIMEonce(theprogrammedtimewillflash).Press
or untilyourselectedstarttimeforMonday’s1stheatingprogramperiodappears.Thetimewillchangein15minuteincrements.When your selected time is displayed, pressTIMEagaintoreturntothechangetemperaturemode.
5. PressPRGMonce.Thecurrentlyprogrammedstart timeandsetpoint temperature for theMonday’s 2nd heatingprogramperiodwillappear.
6. Repeatsteps3and4toselectthestarttimeandheatingtemperatureforMonday’s2ndheatingprogramperiod.
7. Repeatsteps3through5forthe3rdand4thheatingprogramperiods.Mondayheatingprogramsarenowcomplete.
Planning Your ProgramLookat the factory preprogrammed timesand temperaturesshown in the sample schedule. If this program will suit yourneeds,simplypresstheRUNbuttontobeginrunningthefac-torypresetprogram.
Ifyouwanttochangethepreprogrammedtimesandtempera-tures,followthesesteps.
Determine the time periods and temperatures for your dailyprograms.Youmustprogramfourperiodsforboththeweekdayandweekendprogram.However,youmayusethesameheat-ing and cooling temperatures for consecutive time periods.Youcanchoosestart times,heatingtemperatures,andcool-ing temperatures independently for each day programs (forexample,youmayselect5:00AMand70°astheMonday1st period heatingstarttimeandtemperature,andalsochoose7:00AMand76°astheMonday1st period coolingstarttimeandtemperature).
Usethefollowingtabletoplanyourprogramtimeperiodsandthetemperaturesyouwantduringeachperiod.Fillinthecompletetabletohavearecordofyourprograms.
Entering Your ProgramFollowthesestepstoentertheheatingandcoolingprogramsyouhaveselected.
Set Current Time and Day1. PressTIME button once.The display will show the hour
only.
EXAMPLE:PM
PERIOD 1
Time Temp Time Temp
Heating/Cooling Schedule Plan
Mon
Tues
Wed
Thur
Fri
Sat
Sun
HEAT COOL
PERIOD 2
Time Temp Time TempHEAT COOL
PERIOD 3
Time Temp Time TempHEAT COOL
PERIOD 4
Time Temp Time TempHEAT COOL
1ST
2ND
3RD
4TH
1ST
2ND
3RD
4TH
SAMPLEHeating/Cooling Schedule Plan (Factory Program)
6:00AM
8:00AM
5:00PM
10:00PM
6:00AM
8:00AM
5:00PM
10:00PM
70F
62F
70F
62F
78F
85F
78F
82F
ALL DAYS OF THE WEEK
StartTime TemperaturePeriod
CO
OL
HE
AT
2. Pressandholdeither or untilyoureachthecorrecthourandAM/PMdesignation(AMbeginsatmidnight;PMbeginsatnoon).
3. PressTIMEonce.Thedisplaywindowwillshowtheminutesonly.
EXAMPLE:
4. Pressandholdeither or untilyoureachthecorrectminutes.
5. Press TIME once. The display will show the day of theweek.
6. Press or until you reach the current day of theweek.
7. PressRUNonce.Thedisplaywillshowthecorrecttimeandroomtemperaturealternately.
OPERATION
7
NOTEIfyouareprogrammingyourthermostatforthefirsttimeandyouwantprogrammingforalldaysoftheweektobethesameasMonday’sprogram,pressRUNorHOLDatthispoint,andproceedtoEnter Cooling Program.(ThissimplifiedCOPYDAYfeatureonlyworksthefirsttimeyouprogramyourthermostat.Ifyouwanttocopyoneday’sprogrammingtoaspecificdayprogramming,refertoCOPY DAY FUNCTIONinOPERATING FEATURES.Ifyouarechangingyourthermostat’sprogramming,youmustprogrameachdayseparately.)
8. PressHOLDonce.“TU”(indicatingTuesdayprogram)willap-pearinthedisplay,alongwiththestarttimeforthe1stheatingperiodandthecurrentlyprogrammedtemperature.
9. Repeatsteps3 through7 tocompleteTuesday’sheatingprogramming.
10.Continueenteringeachday’sprogramminguntilallheatingperiodstimeandtemperatureshavebeenentered.
11.Whenyouhavecompletedenteringyourheatingprogram,pressRUN.
Enter Cooling Program
If the outside temperature is below 50°F, disconnect power to the cooling system before programming. Energizing the air conditioner compressor during cold weather may cause personal injury or property damage.
▲! CAUTION
Reset OperationIfavoltagespikeorstaticdischargeblanksoutthedisplayorcauseserraticthermostatoperationyoucanresetthethermo-
statbypressing , andTIMEat thesame time.Thisalsoresetsthefactorydefaultstotheconfigurationmenuand
TROUBLESHOOTINGprogram.Ifthethermostathaspower,hasbeenresetandstilldoesnotfunctioncorrectlycontactyourheating/coolingservicepersonorplaceofpurchase.
BatteriesForoptimumperformance,werecommendreplacingbatteriesonceayearwithfresh“AA”Energizer®alkalinebatteries.
1. MoveSYSTEMswitchtoCOOLposition.2. Follow the procedure for entering your cooling program,
usingyourselectedcoolingtimesandtemperatures.
CHECK YOUR PROGRAMMINGFollowthesestepstocheckyourthermostatprogrammingonefinaltimebeforebeginningthermostatoperation.
1. MoveSYSTEMswitchtoHEATposition.2. PressPRGMtoviewthe1stMondayheatingperiodtimeand
temperature.EachtimeyoupressPRGM,thenextheatingperiodtimeandtemperaturewillbedisplayedinsequenceforMonday.PressHOLDtodisplayTuesday’s1stheatingperiod, and press PRGM to view each of the remainingTuesday’sheatingperiod timeand temperatures.Tovieweachday’sheatingprogram,pressHOLDtochangedayandthempressPRGMtolookateachprogrammingperiodfortheday.(Youmaychangeanytimeortemperatureduringthisprocedure.)
3. PressRUN.4. MoveSYSTEMswitchtoCOOLposition.5. Repeatstep2tocheckcoolingprogram.6. MoveSYSTEMswitchtoHEATorCOOLandpressRUNto
beginprogramoperation.YOUR THERMOSTAT IS NOW COMPLETELY PROGRAMMED AND READY TO PROVIDE MAXIMUM COMFORT AND EFFICIENCY!
OPERATION
Symptom Possible Cause Corrective ActionNo Heat/No Cool/No Fan(common problems)
Blownfuseortrippedcircuitbreaker.1.FurnacepowerswitchtoOFF.2.Furnaceblowercompartmentdoororpanel3.looseornotproperlyinstalled.
Replacefuseorresetbreaker.TurnswitchtoON.Replacedoorpanelinproperpositiontoengagesafetyinterlockordoorswitch.
No Heat Pilotlightnotlit.1.SYSTEMSwitchnotsetto2. HEAT.
Looseconnectiontothermostatorsystem.3.
FurnaceLock-OutCondition.Heatmayalso4.beintermittent.
HeatingSystemrequiresserviceor5.thermostatrequiresreplacement.
Re-lightpilot.SetSYSTEMSwitchtoHeat andraisesetpointaboveroomtemperature.Verifythermostatandsystemwiresaresecurelyat-tached.Manyfurnaceshavesafetydevicesthatshutthesys-temdownwhenalock-outconditionoccurs.Iftheheatworksintermittentlycontactthefurnacemanufacturerorlocalservicepersonforassistance.Diagnostic:SetSYSTEMSwitchtoHEATandraisethesetpointaboveroomtemperature.Within afewsecondsthethermostatshouldmakeasoftclicksound.Thissoundusuallyindicatesthethermostatisoperatingproperly.Ifthethermostatdoesnotclick,trytheresetoperationlistedabove.Ifthethermostatdoesnotclickafterbeingresetcontactyourheatingandcoolingservicepersonorplaceofpurchaseforareplacement.Ifthethermostatclicks,contactthefurnacemanufactureroraservicepersontoverifytheheatingsystemisoperatingcorrectly.
TROUBLESHOOTING
Symptom Possible Cause Corrective ActionNo Cool SYSTEMSwitchnotsetto1. COOL below
Looseconnectiontothermostatorsystem.2.CoolingSystemrequiresserviceor3.thermostatrequiresreplacement.
SetSYSTEMSwitchtoCOOLandlowersetpointroomtemperature.Verifythermostatandsystemwiresaresecurelyattached.SameprocedureasdiagnosticforNoHeatconditionexceptsetthethermostattoCOOLandlowerthesetpointbelowtheroomtemperature.TheremaybeuptoafiveminutedelaybeforethethermostatclicksinCoolingifthecompressorlock-outoptionisselectedintheconfigurationmenu(Item6).
Heat, Cool or Fan Runs Constantly. FANSwitchsettoFanON.1.Possibleshortinwiring.2.Possibleshortinthermostat.3.PossibleshortinHeat/Cool/Fansystem.4.
Checkeachwireconnectiontoverifytheyarenotshortedortouchingtogether.Nobarewireshouldstickoutfromunderterminalscrews.Tryresettingthethermostat.IftheconditionpersiststhemanufacturerofyoursystemorservicepersoncaninstructyouonhowtotesttheHeat/Coolsystemforcorrectoperation.Ifthesystemoperatescorrectly,replacethethermostat.
Furnace Cycles Too Fast or Too Slow (narrow or wide temperature swing)
Thelocationofthethermostatand/or1.thesizeoftheHeatingSystemmaybeinfluencingthecyclerate.
Item2intheConfigurationMenuistheadjustmentthatcontrolsthecyclerate.IfanacceptablecyclerateisnotachievedusingtheFA(Fast)orSL(Slow)adjustmentcontactalocalservicepersonforadditionalsuggestions.
Cooling Cycles Too Fast or Too Slow (narrow or wide temperature swing)
Thelocationofthethermostatand/or1.thesizeoftheCoolingSystemmaybeinfluencingthecyclerate.
Thecyclerateforcoolingisfixedandcannotbeadjusted.Contactalocalservicepersonforsuggestions.
Thermostat Setting and Thermometer Disagree
Thermostatthermometersettingrequires1.adjustment.
Thethermometercanbeadjusted+/-4degreesaslistedinitem7oftheConfigurationMenu.Nootheradjustmentispossible.
Clock Loses or Gains Time Lossofpowertothermostatandlow1.batteries.
Thethermostatwillmaintainitsprograminmemoryevenwithnopower/nobatteriesbuttheclocktimewillbeincorrectwhenpowerisrestored.SeeNoHeat/NoCool/NoFan(commonproblems)aboveforitemstocheckinthesystem.
Heat or Cool Starts Early EMRactivated1. SeeConfigurationMenu(Item4).
Thermostat Does Not Follow Program AMorPMsetincorrectlyinprogram.1.AMorPMsetincorrectlyontheclock.2.Voltagespikeorstaticdischarge.3.
CheckcurrentclockandprogramsettingsincludingtheAMorPMdesignationsforeachtimeperiod.IfavoltagespikeorstaticdischargeoccursusetheResetOperationlistedabove.
Blank Display and/or Keypad Not Responding
Lossofpoweranddeadbatteries.1.VoltageSpikeorStaticDischarge.2.
Replacebatteriesandcheckheat/coolsystemforproperoperation.IfavoltagespikeorstaticdischargeoccursusetheResetOperationlistedabove.