19334-E-0-100kWlowspeedDataSheet

download 19334-E-0-100kWlowspeedDataSheet

of 4

Transcript of 19334-E-0-100kWlowspeedDataSheet

  • 8/4/2019 19334-E-0-100kWlowspeedDataSheet

    1/4

    Liquid Cooled Gas Generators100 kW 60Hz

    www.sea.siemens.com/generators

    Data Sheet

    Standard EquipmentJ All input connections in one single areaJ High coolant temperature shutdownJ Low oil pressure shutdownJ Low coolant level automatic shutdownJ Low fuel pressureJ Overspeed automatic shutdownJ Adjustable cranking timerJ Adjustable exercise timer

    J Oil drain extensionJ Cool ow radiator

    J Closed coolant recovery systemJ UV/Ozone resistant hosesJ Watertight state of the art electrical connectorsJ Mainline circuit breakerJ Oil drain extension to frame railJ Radiator drain extensionJ Battery charge alternatorJ 10 Amp static battery chargerJ Battery and battery cablesJ Battery rackJ Fan and belt guardsJ Isochronous governorJ Coolant heater

    FeaturesJ Innovative design and fully prototype testedJ UL2200 ListedJ Solid state frequency compensated digital voltage

    regulatorJ Dynamic and static battery chargerJ Sound attenuated acoustically designed enclosureJ Quiet test for low noise level exerciseJ Acoustically designed engine cooling systemJ High ow low noise factory engineered exhaust

    systemJ State of the art digital control system with H-100

    microprocessor control panelJ Built-in kW, kVAR and power factor metersJ Watertight electrical connectorsJ Rodent proof constructionJ High efciency, low distortion Generac designed

    alternatorJ Vibration isolated from mounting baseJ Matching Siemens transfer switches engineered and

    tested to work as a systemJ Electrostatically applied powder paint

    6.8L EngineNaturally AspiratedGaseous FueledGear Drive

  • 8/4/2019 19334-E-0-100kWlowspeedDataSheet

    2/4

    Generator Specifications

    Type Synchronous

    Rotor Insulation Class H

    Stator Insulation Class H

    Total Harmonic Distortion

  • 8/4/2019 19334-E-0-100kWlowspeedDataSheet

    3/4

    kW Rating 100

    Engine Size 2.4 Liter Inline 4

    Generator Output Voltage/kW - 60Hz120/240V, 1-phase, 1.0 pf120/208V, 3-phase, 0.8 pf120/208V, 3-phase, 0.8 pf277/480V, 3-phase, 0.8 pf

    600V, 3-phase, 0.8 pf

    kW Amp CB Size100 417 500100 300 350100 347 400100 150 175100 120 150

    Generator Locked Rotor KVAAvailable @ Voltage Dip of 35%

    Single phase or 208 3-phase480V 3-phase

    200240

    Engine Fuel Consumption (Natural Gas) (Propane)

    Exercise cycle25% of rated load50% of rated load

    75% of rated load100% of rated load

    Natural Gas Propane(ft3/hr) (gal/hr) (cu ft/hr)

    130 1.42 52.3371 4.06 149.4713 7.81 287.4

    994 10.88 400.41260 13.80 507.8

    Engine CoolingAir flow (inlet air including alternator and combusiton air) ft3/min.System coolant capacity US gal.Heat rejection to coolant BTU/hr.Max. operating air temp. on radiator C (F)Max. ambient temperature C (F)

    5,5004.5

    342,00060 (150)50 (140)

    Combustion Air RequirementsFlow at rated power 60 Hz cfm

    262

    Sound Emissions in DBAExercising at 7 metersNormal operation at 7 meters

    6172

    ExhaustExhaust flow at rated output 60 Hz cfmExhaust temp. at muffler outlet F

    888960

    Engine ParametersRated sychronous RPM 60 HzHP at rated kW 60 Hz

    2300168

    Power Adjustment For Ambient ConditionsTemperature Deration

    3% for every 10 C above - C1.65% for every 10 F above - F

    Altitude Deration1% for every 100 m above - m

    3% for every 1000 ft. above - ft.

    2577

    183600

    Operating Data100kW Liquid Cooled

    RATING: All three phases units are rated at 0.8 power factor. All single phase units are rated at 1.0 power factor. STANDBY RATING: Standby ratings apply

    to installations served by a reliable utility source. The standyb rating is applicable to varying loads for the duration of a power outage. There is no overload

    capability for this rating. Ratings are in accordance with ISO-3046-1. Design and specifications are subject to change without notice.

  • 8/4/2019 19334-E-0-100kWlowspeedDataSheet

    4/4

    Transfer Switch

    H100 Control Panel Utility In

    Gen

    LoadOut

    GeneratorConnectionBox

    15 Amp 120Volt BattChargerCircuit

    2 Wire Shielded CableW/Ground To TransferSW. GRDD @ GENSETOnly.

    Stub-Up AreaSee Detail f or DimensionsReference Installation Dwg.0G1408 - Enclosed Set0G1541 - Open Set

    Ground Level

    To Generator Control Panel

    2 Wire ShieldedCable W/GroundTo Generator

    ToAlternator

    CIRCUIT BREAKER SIZEKW VOLTS CB AMPS LUG SIZE100 240 1 500 3-2/0 to 400 mcm

    100 240 3 350 2-3/0 to 500 mcm100 208 3 400 (1) 600 MCM or (2) 1/0)100 480 3 175 #6 to 300 mcm100 600 3 150 #6 to 350 mcm

    Interconnections100kW Liquid Cooled

    Installation Layout100kW Liquid Cooled

    . .

    -

    .--

    Note:Door accessfrom both sides

    Door

    Siemens Energy & Automation, Inc.

    3333 Old Milton Parkway

    Alpharetta, GA 30005

    1-800-964-4114

    [email protected]

    2008 Siemens Energy & Automation, In

    All Rights Reserved. Siemens is a register

    trademark of Siemens AG. Product names

    mentioned may be trademarks or registe

    trademarks of their respective companies

    Specifications are subject to change with

    notice.

    RPFL-QT100-0908 (New) 0908POD

    www.sea.siemens.com/generato