160 Meter Shunt Fed Tower Omega Match - aricuneo.it TECNICA/antenne-varie/160MeterShuntFed.pdf ·...
Transcript of 160 Meter Shunt Fed Tower Omega Match - aricuneo.it TECNICA/antenne-varie/160MeterShuntFed.pdf ·...
![Page 1: 160 Meter Shunt Fed Tower Omega Match - aricuneo.it TECNICA/antenne-varie/160MeterShuntFed.pdf · 160 M Shunt Fed Tower Remote Control 24V DC for cap motors. W8RA 160 M Shunt Fed](https://reader030.fdocuments.net/reader030/viewer/2022040908/5e808f07dc938956377d3099/html5/thumbnails/1.jpg)
160 Meters
130 foot free standing tower
shunt fed with Omega Match
W8RA
160 M Shunt Fed Tower
Bruce Whitney
W8RA April 2010
![Page 2: 160 Meter Shunt Fed Tower Omega Match - aricuneo.it TECNICA/antenne-varie/160MeterShuntFed.pdf · 160 M Shunt Fed Tower Remote Control 24V DC for cap motors. W8RA 160 M Shunt Fed](https://reader030.fdocuments.net/reader030/viewer/2022040908/5e808f07dc938956377d3099/html5/thumbnails/2.jpg)
Tower:– 100 ft ‘utility’ lattice transmission tower
un-guyed (12,000 pounds mild steel)– Mast 30 ft street lighting pole 8 5/8” diam.– Antenna – SteppIR/MonstIR at 130 feet
Feeder– Cage feeder – 12 ½” diam., 8 wire cage
bolted to tower at 82 feet, spaced @ 31”
Match– Omega Match (shunt-series)– Remote control - motor operated tuning
Radials– 64, ¼ wave radials pushed down in slits
cut in sod
W8RA
160 M Shunt Fed Tower
![Page 3: 160 Meter Shunt Fed Tower Omega Match - aricuneo.it TECNICA/antenne-varie/160MeterShuntFed.pdf · 160 M Shunt Fed Tower Remote Control 24V DC for cap motors. W8RA 160 M Shunt Fed](https://reader030.fdocuments.net/reader030/viewer/2022040908/5e808f07dc938956377d3099/html5/thumbnails/3.jpg)
W8RA
160 M Shunt Fed Tower
Construction and Tuning:
Tap Height and spacingadjustable
![Page 4: 160 Meter Shunt Fed Tower Omega Match - aricuneo.it TECNICA/antenne-varie/160MeterShuntFed.pdf · 160 M Shunt Fed Tower Remote Control 24V DC for cap motors. W8RA 160 M Shunt Fed](https://reader030.fdocuments.net/reader030/viewer/2022040908/5e808f07dc938956377d3099/html5/thumbnails/4.jpg)
W8RA
160 M Shunt Fed Tower
Remote Control24V DC for capmotors
![Page 5: 160 Meter Shunt Fed Tower Omega Match - aricuneo.it TECNICA/antenne-varie/160MeterShuntFed.pdf · 160 M Shunt Fed Tower Remote Control 24V DC for cap motors. W8RA 160 M Shunt Fed](https://reader030.fdocuments.net/reader030/viewer/2022040908/5e808f07dc938956377d3099/html5/thumbnails/5.jpg)
W8RA
160 M Shunt Fed Tower
Omega Match
Motor operated forboth local and remotetuning
Connected as shunt-series rather thanseries-shunt
![Page 6: 160 Meter Shunt Fed Tower Omega Match - aricuneo.it TECNICA/antenne-varie/160MeterShuntFed.pdf · 160 M Shunt Fed Tower Remote Control 24V DC for cap motors. W8RA 160 M Shunt Fed](https://reader030.fdocuments.net/reader030/viewer/2022040908/5e808f07dc938956377d3099/html5/thumbnails/6.jpg)
W8RA
160 M Shunt Fed Tower
Omega Match
Connected to 8wire cage
Single pointgrounding to tower
Picture takenbefore radials
Tower grounded to8, ten foot ¾” diam.rods, exothermicwelded to 4 gaugestranded copper
![Page 7: 160 Meter Shunt Fed Tower Omega Match - aricuneo.it TECNICA/antenne-varie/160MeterShuntFed.pdf · 160 M Shunt Fed Tower Remote Control 24V DC for cap motors. W8RA 160 M Shunt Fed](https://reader030.fdocuments.net/reader030/viewer/2022040908/5e808f07dc938956377d3099/html5/thumbnails/7.jpg)
W8RA
160 M Shunt Fed Tower
![Page 8: 160 Meter Shunt Fed Tower Omega Match - aricuneo.it TECNICA/antenne-varie/160MeterShuntFed.pdf · 160 M Shunt Fed Tower Remote Control 24V DC for cap motors. W8RA 160 M Shunt Fed](https://reader030.fdocuments.net/reader030/viewer/2022040908/5e808f07dc938956377d3099/html5/thumbnails/8.jpg)
W8RA
160 M Shunt Fed Tower
![Page 9: 160 Meter Shunt Fed Tower Omega Match - aricuneo.it TECNICA/antenne-varie/160MeterShuntFed.pdf · 160 M Shunt Fed Tower Remote Control 24V DC for cap motors. W8RA 160 M Shunt Fed](https://reader030.fdocuments.net/reader030/viewer/2022040908/5e808f07dc938956377d3099/html5/thumbnails/9.jpg)
W8RA
160 M Shunt Fed Tower
50 Ohm Coax toShack
C Shunt
C Series
8 Wire Cage82 ft tall, 12 ½” diam.31” spacing center to tower
Tower 100 ft tall2’x2’ base, 1’x1’ @ top
Mast 30 ft tall8 5/8” diam base, 4” @ top
SteppIR MonstIR 36 ft boom3 full size 40M elements (retracted) Equivalent Circuit
Measured at bottom of cage feeder (AIM 4170)
1.80 MHz: R=40.1 X=261.81.85 MHz: R=40.7 X=285.2
Network Design SoftwareL Net matching calculations:
1.80 MHz: Cshunt=884.2pF Cseries=365.4pF
1.85 MHz: Cshunt=806.1pF Cseries=323.7pF
Caps measured after tuning for min SWR:
Cshunt=654pF Cseries=338pF
R
X Cseries
Cshunt
50 Ώ
![Page 10: 160 Meter Shunt Fed Tower Omega Match - aricuneo.it TECNICA/antenne-varie/160MeterShuntFed.pdf · 160 M Shunt Fed Tower Remote Control 24V DC for cap motors. W8RA 160 M Shunt Fed](https://reader030.fdocuments.net/reader030/viewer/2022040908/5e808f07dc938956377d3099/html5/thumbnails/10.jpg)
W8RA
160 M Shunt Fed Tower
Bandwidth (approx.)2:1 SWR:100KHZ1.5:1 SWR: 50 KHZ
![Page 11: 160 Meter Shunt Fed Tower Omega Match - aricuneo.it TECNICA/antenne-varie/160MeterShuntFed.pdf · 160 M Shunt Fed Tower Remote Control 24V DC for cap motors. W8RA 160 M Shunt Fed](https://reader030.fdocuments.net/reader030/viewer/2022040908/5e808f07dc938956377d3099/html5/thumbnails/11.jpg)
W8RA
160 M Shunt Fed Tower
Bandwidth (approx.)2:1 SWR:100KHZ1.5:1 SWR: 50 KHZ