5
203 202 WEB www.fitzlight.co.uk email [email protected] TEL 01208 79524 FAX 01208 72832 Photometric data is available on-line for DiaLux and ReLux FORNAX ZONE 1 CORROSION RESISTANT FLUORESCENT LUMINAIRES For hazardous area lighting A general purpose Zone 1 ATEX Category 2 flameproof luminaire - EEx d, interior or exterior surface or suspended fluorescent luminaire for Zone 1 applications. Product Specification • Certified ingress protection to IP66 • Anodised marine grade aluminium • Lightweight slimline compact construction • 2 pack aqua epoxy paint finish on pre- treated and primed surface. • Polycarbonate cover • Tested to meet ATEX requirements (compulsory since 2003) • Integral control gear • 2 X M8 tapped mounting holes - vertical and horizontal - at each end • 2 X M20 - ISO (1 plugged) cable entries each end - other thread forms available • 3 wire and earth terminals - cable size 4mm 2 max with looping Applications: • Category 2 Zone 1 nominated hazardous areas Ambient temperature guidance High frequency -20˚C - +55˚C Integral emergency 0˚C - +55˚C Order Codes Excluding Lamps - HF as standard Order Code Watt A L FP118/HF/X 1 x 18 632 752 FP136/HF/X 1 x 36 1242 1362 FP158/HF/X 1 x 58 1542 1662 FP170/HF/X 1 x 17 1806 1926 FP218/HF/X 2 x 18 632 752 FP236/HF/X 2 x 36 1242 1362 FP258/HF/X 2 x 58 1542 1662 FP270/HF/X 2 x 70 1806 1926 Note this product is not always held in stock - please allow up to 6 weeks to guarantee delivery. A 158 140 L Gear options /M3: Maintained Emergency Lamp Options T8: 26mm Fluorescent Tubes Designed and manufactured to comply with standards: EN60079, EN61241, IEC 60079 and IEC61241. IP66 Installation Exposed T 6 Plasterboard 6 Metal Pan 6 Surface 4 Suspended 6 Separate Battery Chamber

Transcript of 158 L 140 - Fitzgerald Lighting · For hazardous area lighting A general purpose Zone 1 ATEX...

203202WEB www.fitzlight.co.uk email [email protected] 01208 79524 FAX 01208 72832 Photometric data is available on-line for DiaLux and ReLux

F O R N A XZONE 1 CORROSION RESISTANT FLUORESCENT LUMINAIRES

For hazardous area lighting

A general purpose Zone 1 ATEX

Category 2 flameproof luminaire -

EEx d, interior or exterior surface or

suspended fluorescent luminaire for

Zone 1 applications.

Product Specification

• Certified ingress protection to IP66

• Anodised marine grade aluminium

• Lightweight slimline compact construction

• 2 pack aqua epoxy paint finish on pre-treated and primed surface.

• Polycarbonate cover

• Tested to meet ATEX requirements (compulsory since 2003)

• Integral control gear

• 2 X M8 tapped mounting holes - vertical and horizontal - at each end

• 2 X M20 - ISO (1 plugged) cable entries each end - other thread forms available

• 3 wire and earth terminals - cable size 4mm2 max with looping

Applications:

• Category 2 Zone 1 nominated hazardous areas

Ambient temperature guidance

High frequency -20˚C - +55˚CIntegral emergency 0˚C - +55˚C

Order Codes Excluding Lamps - HF as standard Order Code Watt A L

FP118/HF/X 1 x 18 632 752

FP136/HF/X 1 x 36 1242 1362

FP158/HF/X 1 x 58 1542 1662

FP170/HF/X 1 x 17 1806 1926

FP218/HF/X 2 x 18 632 752

FP236/HF/X 2 x 36 1242 1362

FP258/HF/X 2 x 58 1542 1662

FP270/HF/X 2 x 70 1806 1926

Note this product is not always held in stock - please allow up to 6 weeks to guarantee delivery.

A

158

140L

Gear options /M3: Maintained Emergency

Lamp Options

T8: 26mm Fluorescent Tubes

Designed and manufactured to comply with standards: EN60079, EN61241, IEC 60079 and IEC61241.

IP66

InstallationExposed T 6Plasterboard 6Metal Pan 6Surface 4Suspended 6

Separate Battery Chamber

205204WEB www.fitzlight.co.uk email [email protected] 01208 79524 FAX 01208 72832 Photometric data is available on-line for DiaLux and ReLux

AV I O RZONE 1 CORROSION RESISTANT FLUORESCENT LUMINAIRES

For hazardous area lighting

Order Codes Excluding Lamps T8 Tube

Order Code Watt L A Kg

AVI218/HF/X 2 x 18 765 450 6.8

AVI236/HF/X 2 x 36 1375 1060 10.4

AVI258/HF/X 2 x 58 1675 1260 12.0

Note this product is not always held in stock - please allow up to 6 weeks to guarantee delivery.

Product Specification

• Certified ingress protection to IP65

• ATEX certified

• High efficiency class leading photometric performance

• High frequency control gear

• Rugged construction with flexible mounting centres

• Single point locking arrangement for the diffuser guarantees a perfect seal and easy maintenance

• Fire retardant UV stabilised impact resistant polycarbonate body and diffuser

• Quality control gear and sub components for maximum service life

• Modern tooling ensures precision mouldings for a perfect construction every time

Lamp Options

T8: 26mm Fluorescent Tubes

192

A - Max fixing centres

L

142

Applications:

• Category 2 Zone 1 nominated hazardous areas

Ambient temperature guidance

High frequency -20˚C - +55˚CIntegral emergency 0˚C - +55˚C

High efficiency Category 2 (Zone 1) highly durable and

versatile fluorescent luminaires which offer resistance to

impact and the adverse effects of moisture,

dirt and dust.

Certification code: EEx ed IIC 2G 3D

T4 (Tamb -20 to +55 degrees centigrade).

T5 (Tamb -20 to +25 degrees centigrade).

Certificate number: SIRA 00 ATEX 3071.

Emergency options /M3: 3hr Maintained Emergency

Avior Part Code Formula:

Product Number Lamp / Gear / Lamp / Emergency Family of Lamps Watts Option Type Option

AVI 2 18 HF X M3

InstallationExposed T 6Plasterboard 6Metal Pan 6Surface 4Suspended 6

Designed and manufactured to comply with standards: EN60079, EN61241, IEC 60079 and IEC 61241.

Adjustable mounting position

IP20 IP20

IP20 IP20

IP20

IP20

207206WEB www.fitzlight.co.uk email [email protected] 01208 79524 FAX 01208 72832 Photometric data is available on-line for DiaLux and ReLux

M I N TA K A ZONE 2 CORROSION RESISTANT FLUORESCENT LUMINAIRES

For hazardous area lighting

Optional Accessories (Add suffix to order code)

/MIN-HANGERC1: Stainless steel mounting clips for single body

/MIN-HANGERC2: Stainless steel mounting clips for twin body

Order Codes Excluding Lamps T8 Tube

Order Code Watt L A Clips Kg

MIN136/HF/X 1 x 36 1312 800 8 3.0

MIN158/HF/X 1 x 58 1612 1100 10 4.0

MIN218/HF/X 2 x 18 702 500 4 4.5

MIN236/HF/X 2 x 36 1312 800 8 4.5

MIN258/HF/X 2 x 58 1612 1100 10 5.0

Product Specification

• Certified ingress protection to IP65

• Suitable for gas and dust areas

• Unrestricted breathing enclosure, no need for annual gasket inspection or pressure testing

• Stainless steel diffuser retention clips

• Fire retardant UV stabilised impact resistant injection moulded polycarbonate diffuser

• Glass fibre re-enforced polyester body for maximum durability

• Diffuser retention clips can be locked for improved vandal resistance

• Quality high frequency control gear and sub components for maximum service life

• Modern tooling ensures precision mouldings for a perfect fit every time

• Poured neoprene closed cell anti-ageing gasket for a perfect seal

Lamp Options

T8: 26mm Fluorescent Tubes

108

L

A

102 172

Designed and manufactured to comply with EN 50021 and are CE certified.

Applications:

• Category 3 Zone 2 nominated hazardous areas

Ambient temperature guidance

High frequency -40˚C - +55˚CIntegral emergency 0˚C - +25˚C

High efficiency Category 3 (Zone 2 and 22) highly durable

and versatile luminaires which offer resistance to impact

and the adverse effects of moisture, dirt and dust.

Certification code: EEx n c II 3 GD T4

(Tamb -40 to +55 degrees centigrade).

Certificate number: Epsilon EX02ATEX1167.

Emergency options /M3: 3hr Maintained Emergency

Mintaka Part Code Formula:

Product Number Lamp / Gear / Lamp / Emergency Family of Lamps Watts Option Type Option

MIN 2 58 HF X M3

InstallationExposed T 6Plasterboard 6Metal Pan 6Surface 4Suspended 4

IP20 IP20

IP20 IP20

IP20

IP20

209208WEB www.fitzlight.co.uk email [email protected] 01208 79524 FAX 01208 72832 Photometric data is available on-line for DiaLux and ReLux

I Z A RZONE 2 BULKHEAD LUMINAIRES

For hazardous area lighting

A Zone 2 bulkhead for areas with

restricted access or low mounting

heights.

The Izar has a hinged lens

opening for ease on maintenance

allowing for rapid lamp and

control gear access.

Product Specification

• Certified ingress protection to IP65

• Even light distribution

• Zone 2 cast aluminium bulkhead

• Aluminium alloy body finished with grey stoved enamel

• Prismatic glass enclosure

• Control gear has integral magnetic ballast, ignitor and capacitor

• Installation/Mounting - 4 fixing holes 6mm

• Cables entries 2 x M20 with one entry fitted with removable plug

• Terminals: 2 wire plus earth - max conductor 4mm2

Applications:

• Catagory 3, Zone 2 nominated hazardous areas

Order Codes Excluding Lamps Order Code Watt Kg Lamp

IZR70SON/X 1 x 70 6.0 SON

Certification code EExnCII3GDT3, certification standard EN60079-0, 15. Lamp Options

SON: Elliptical Diffuse High Pressure Sodium with Integral Ignitor

PL-L: Compact Fluorescent

Ambient temperature guidance

-20˚C - +30˚C

312

190

90170

162

IP20 IP20

IP20 IP20

IP20

IP20

211210WEB www.fitzlight.co.uk email [email protected] 01208 79524 FAX 01208 72832 Photometric data is available on-line for DiaLux and ReLux

C E T U SZONE 1 BULKHEAD LUMINAIRES

For hazardous area lighting

An Atex certified Catagory 2, Zone 1 fitting

suitable for hazardous environments.

Product Specification

• Certified ingress protection to IP66

• Control gear (when fitted) has integral magnetic ballast, ignitor and capacitor

• 2 pack epoxy paint on primed - surface standard colour aqua

• Corrosion resistant marine grade aluminium body and bezel - toughened glass dome

• Terminals accessed via terminal cover retained by cap screws - lamp and gear accessed via removable glass dome

• Back mounted fixing strap

• Cables entries 2 x M20 with one entry fitted with removable plug

• Terminals: 4 (4mm) wire plus earth with looping facility (cable crimping required at installation when looping

Applications:

• Catagory 2, Zone 1 nominated hazardous areas

Order Codes Excluding Lamps (excluding GLS version) Order Code Watt Kg Lamp

CET50SON/X 1 x 55 14.0 SON

CET70SON/X 1 x 70 14.0 SON

CET50MBF/X 1 x 50 14.0 MBF

CET80MBF/X 1 x 80 14.0 MBF

CET125MBF/X 1 x 125 14.0 MBF

Certification code ExdeII2GDIICT3-T6, certification standard EN60079, EN61241 and IEC61241.

Optional Features (Add suffix to order code)

/WG: Wire guard

/PB: Pivot bracket for directional control

/PM: Pendant mount

/IR: Internal reflector

/ER: External reflector

Lamp Options

SON: Elliptical Diffuse High Pressure Sodium with Integral Ignitor

MBF: Elliptical Diffuse Mercury

Ambient temperature guidance

-20˚C - +40˚C

IP66

334

194298

OPTIONAL PIVOT BRACKET

287