203202WEB www.fitzlight.co.uk email [email protected] 01208 79524 FAX 01208 72832 Photometric data is available on-line for DiaLux and ReLux
F O R N A XZONE 1 CORROSION RESISTANT FLUORESCENT LUMINAIRES
For hazardous area lighting
A general purpose Zone 1 ATEX
Category 2 flameproof luminaire -
EEx d, interior or exterior surface or
suspended fluorescent luminaire for
Zone 1 applications.
Product Specification
• Certified ingress protection to IP66
• Anodised marine grade aluminium
• Lightweight slimline compact construction
• 2 pack aqua epoxy paint finish on pre-treated and primed surface.
• Polycarbonate cover
• Tested to meet ATEX requirements (compulsory since 2003)
• Integral control gear
• 2 X M8 tapped mounting holes - vertical and horizontal - at each end
• 2 X M20 - ISO (1 plugged) cable entries each end - other thread forms available
• 3 wire and earth terminals - cable size 4mm2 max with looping
Applications:
• Category 2 Zone 1 nominated hazardous areas
Ambient temperature guidance
High frequency -20˚C - +55˚CIntegral emergency 0˚C - +55˚C
Order Codes Excluding Lamps - HF as standard Order Code Watt A L
FP118/HF/X 1 x 18 632 752
FP136/HF/X 1 x 36 1242 1362
FP158/HF/X 1 x 58 1542 1662
FP170/HF/X 1 x 17 1806 1926
FP218/HF/X 2 x 18 632 752
FP236/HF/X 2 x 36 1242 1362
FP258/HF/X 2 x 58 1542 1662
FP270/HF/X 2 x 70 1806 1926
Note this product is not always held in stock - please allow up to 6 weeks to guarantee delivery.
A
158
140L
Gear options /M3: Maintained Emergency
Lamp Options
T8: 26mm Fluorescent Tubes
Designed and manufactured to comply with standards: EN60079, EN61241, IEC 60079 and IEC61241.
IP66
InstallationExposed T 6Plasterboard 6Metal Pan 6Surface 4Suspended 6
Separate Battery Chamber
205204WEB www.fitzlight.co.uk email [email protected] 01208 79524 FAX 01208 72832 Photometric data is available on-line for DiaLux and ReLux
AV I O RZONE 1 CORROSION RESISTANT FLUORESCENT LUMINAIRES
For hazardous area lighting
Order Codes Excluding Lamps T8 Tube
Order Code Watt L A Kg
AVI218/HF/X 2 x 18 765 450 6.8
AVI236/HF/X 2 x 36 1375 1060 10.4
AVI258/HF/X 2 x 58 1675 1260 12.0
Note this product is not always held in stock - please allow up to 6 weeks to guarantee delivery.
Product Specification
• Certified ingress protection to IP65
• ATEX certified
• High efficiency class leading photometric performance
• High frequency control gear
• Rugged construction with flexible mounting centres
• Single point locking arrangement for the diffuser guarantees a perfect seal and easy maintenance
• Fire retardant UV stabilised impact resistant polycarbonate body and diffuser
• Quality control gear and sub components for maximum service life
• Modern tooling ensures precision mouldings for a perfect construction every time
Lamp Options
T8: 26mm Fluorescent Tubes
192
A - Max fixing centres
L
142
Applications:
• Category 2 Zone 1 nominated hazardous areas
Ambient temperature guidance
High frequency -20˚C - +55˚CIntegral emergency 0˚C - +55˚C
High efficiency Category 2 (Zone 1) highly durable and
versatile fluorescent luminaires which offer resistance to
impact and the adverse effects of moisture,
dirt and dust.
Certification code: EEx ed IIC 2G 3D
T4 (Tamb -20 to +55 degrees centigrade).
T5 (Tamb -20 to +25 degrees centigrade).
Certificate number: SIRA 00 ATEX 3071.
Emergency options /M3: 3hr Maintained Emergency
Avior Part Code Formula:
Product Number Lamp / Gear / Lamp / Emergency Family of Lamps Watts Option Type Option
AVI 2 18 HF X M3
InstallationExposed T 6Plasterboard 6Metal Pan 6Surface 4Suspended 6
Designed and manufactured to comply with standards: EN60079, EN61241, IEC 60079 and IEC 61241.
Adjustable mounting position
IP20 IP20
IP20 IP20
IP20
IP20
207206WEB www.fitzlight.co.uk email [email protected] 01208 79524 FAX 01208 72832 Photometric data is available on-line for DiaLux and ReLux
M I N TA K A ZONE 2 CORROSION RESISTANT FLUORESCENT LUMINAIRES
For hazardous area lighting
Optional Accessories (Add suffix to order code)
/MIN-HANGERC1: Stainless steel mounting clips for single body
/MIN-HANGERC2: Stainless steel mounting clips for twin body
Order Codes Excluding Lamps T8 Tube
Order Code Watt L A Clips Kg
MIN136/HF/X 1 x 36 1312 800 8 3.0
MIN158/HF/X 1 x 58 1612 1100 10 4.0
MIN218/HF/X 2 x 18 702 500 4 4.5
MIN236/HF/X 2 x 36 1312 800 8 4.5
MIN258/HF/X 2 x 58 1612 1100 10 5.0
Product Specification
• Certified ingress protection to IP65
• Suitable for gas and dust areas
• Unrestricted breathing enclosure, no need for annual gasket inspection or pressure testing
• Stainless steel diffuser retention clips
• Fire retardant UV stabilised impact resistant injection moulded polycarbonate diffuser
• Glass fibre re-enforced polyester body for maximum durability
• Diffuser retention clips can be locked for improved vandal resistance
• Quality high frequency control gear and sub components for maximum service life
• Modern tooling ensures precision mouldings for a perfect fit every time
• Poured neoprene closed cell anti-ageing gasket for a perfect seal
Lamp Options
T8: 26mm Fluorescent Tubes
108
L
A
102 172
Designed and manufactured to comply with EN 50021 and are CE certified.
Applications:
• Category 3 Zone 2 nominated hazardous areas
Ambient temperature guidance
High frequency -40˚C - +55˚CIntegral emergency 0˚C - +25˚C
High efficiency Category 3 (Zone 2 and 22) highly durable
and versatile luminaires which offer resistance to impact
and the adverse effects of moisture, dirt and dust.
Certification code: EEx n c II 3 GD T4
(Tamb -40 to +55 degrees centigrade).
Certificate number: Epsilon EX02ATEX1167.
Emergency options /M3: 3hr Maintained Emergency
Mintaka Part Code Formula:
Product Number Lamp / Gear / Lamp / Emergency Family of Lamps Watts Option Type Option
MIN 2 58 HF X M3
InstallationExposed T 6Plasterboard 6Metal Pan 6Surface 4Suspended 4
IP20 IP20
IP20 IP20
IP20
IP20
209208WEB www.fitzlight.co.uk email [email protected] 01208 79524 FAX 01208 72832 Photometric data is available on-line for DiaLux and ReLux
I Z A RZONE 2 BULKHEAD LUMINAIRES
For hazardous area lighting
A Zone 2 bulkhead for areas with
restricted access or low mounting
heights.
The Izar has a hinged lens
opening for ease on maintenance
allowing for rapid lamp and
control gear access.
Product Specification
• Certified ingress protection to IP65
• Even light distribution
• Zone 2 cast aluminium bulkhead
• Aluminium alloy body finished with grey stoved enamel
• Prismatic glass enclosure
• Control gear has integral magnetic ballast, ignitor and capacitor
• Installation/Mounting - 4 fixing holes 6mm
• Cables entries 2 x M20 with one entry fitted with removable plug
• Terminals: 2 wire plus earth - max conductor 4mm2
Applications:
• Catagory 3, Zone 2 nominated hazardous areas
Order Codes Excluding Lamps Order Code Watt Kg Lamp
IZR70SON/X 1 x 70 6.0 SON
Certification code EExnCII3GDT3, certification standard EN60079-0, 15. Lamp Options
SON: Elliptical Diffuse High Pressure Sodium with Integral Ignitor
PL-L: Compact Fluorescent
Ambient temperature guidance
-20˚C - +30˚C
312
190
90170
162
IP20 IP20
IP20 IP20
IP20
IP20
211210WEB www.fitzlight.co.uk email [email protected] 01208 79524 FAX 01208 72832 Photometric data is available on-line for DiaLux and ReLux
C E T U SZONE 1 BULKHEAD LUMINAIRES
For hazardous area lighting
An Atex certified Catagory 2, Zone 1 fitting
suitable for hazardous environments.
Product Specification
• Certified ingress protection to IP66
• Control gear (when fitted) has integral magnetic ballast, ignitor and capacitor
• 2 pack epoxy paint on primed - surface standard colour aqua
• Corrosion resistant marine grade aluminium body and bezel - toughened glass dome
• Terminals accessed via terminal cover retained by cap screws - lamp and gear accessed via removable glass dome
• Back mounted fixing strap
• Cables entries 2 x M20 with one entry fitted with removable plug
• Terminals: 4 (4mm) wire plus earth with looping facility (cable crimping required at installation when looping
Applications:
• Catagory 2, Zone 1 nominated hazardous areas
Order Codes Excluding Lamps (excluding GLS version) Order Code Watt Kg Lamp
CET50SON/X 1 x 55 14.0 SON
CET70SON/X 1 x 70 14.0 SON
CET50MBF/X 1 x 50 14.0 MBF
CET80MBF/X 1 x 80 14.0 MBF
CET125MBF/X 1 x 125 14.0 MBF
Certification code ExdeII2GDIICT3-T6, certification standard EN60079, EN61241 and IEC61241.
Optional Features (Add suffix to order code)
/WG: Wire guard
/PB: Pivot bracket for directional control
/PM: Pendant mount
/IR: Internal reflector
/ER: External reflector
Lamp Options
SON: Elliptical Diffuse High Pressure Sodium with Integral Ignitor
MBF: Elliptical Diffuse Mercury
Ambient temperature guidance
-20˚C - +40˚C
IP66
334
194298
OPTIONAL PIVOT BRACKET
287