15 MAE Flameproof Alternator 500W · 2019. 6. 29. · Page 5 of 7 Members: M. Lo Giudice; G. Lo...
Transcript of 15 MAE Flameproof Alternator 500W · 2019. 6. 29. · Page 5 of 7 Members: M. Lo Giudice; G. Lo...
-
Page 1 of 7 Members: M. Lo Giudice; G. Lo Giudice;
MAE MANUFACTURERS cc MANUFACTURERS OF THE MAE FLAMEPROOF ALTERNATOR AND ELECTRICAL FLAMEPROOF EQUIPMENT
REG NO: CK 95/47371/23 VAT NO: 447 011 0034
Tel: +27 (11) 421 5551 Fax: +27 (11) 421 5618
E-mail: [email protected] / [email protected]
MOD.15 MAE Flameproof Alternator 500W Part No: MAEF001215/HA
12 or 24 Volts. Flameproof & Dustproof. Single, Double or Triple Pulley. 500 Watts. Internal short circuit device. Indicator Charge Pilot Light.
Product Features
-
Page 2 of 7 Members: M. Lo Giudice; G. Lo Giudice;
MAE MANUFACTURERS cc MANUFACTURERS OF THE MAE FLAMEPROOF ALTERNATOR AND ELECTRICAL FLAMEPROOF EQUIPMENT
REG NO: CK 95/47371/23 VAT NO: 447 011 0034
Tel: +27 (11) 421 5551 Fax: +27 (11) 421 5618
E-mail: [email protected] / [email protected]
Output Max 500W Input Voltage 12V or 24V Certificate M-SGS/98214 Weight 23kg Overall Length 259mm Overall Diameter 164mm
Applications
Technical Specifications
-
Page 3 of 7 Members: M. Lo Giudice; G. Lo Giudice;
MAE MANUFACTURERS cc MANUFACTURERS OF THE MAE FLAMEPROOF ALTERNATOR AND ELECTRICAL FLAMEPROOF EQUIPMENT
REG NO: CK 95/47371/23 VAT NO: 447 011 0034
Tel: +27 (11) 421 5551 Fax: +27 (11) 421 5618
E-mail: [email protected] / [email protected]
2x 6305 bearings are situated after the pulley. This allows for greater fan-belt torque without the danger of damage to the alternator interior parts. A 3rd 6201 bearing is used on the opposite side of the shaft for rotor stability. “See Figure 1”
In the case where there is an electrical short in the wiring system, an electronic circuit has been incorporated into the
regulator system which detects and automatically cuts off the field input when the amp draw is greater than the amp
capacity of the alternators output.
NOTE: When a short circuit occurs in the electrical system, the alternator will automatically shut down. Once the
short has been repaired, the alternator will automatically start operating. The short circuit in the wiring system can be
indefinite without causing any damage to the alternator.
Main Features
1. Front Bearings
2. Internal Short Circuit Device
-
Page 4 of 7 Members: M. Lo Giudice; G. Lo Giudice;
MAE MANUFACTURERS cc MANUFACTURERS OF THE MAE FLAMEPROOF ALTERNATOR AND ELECTRICAL FLAMEPROOF EQUIPMENT
REG NO: CK 95/47371/23 VAT NO: 447 011 0034
Tel: +27 (11) 421 5551 Fax: +27 (11) 421 5618
E-mail: [email protected] / [email protected]
An LED is situated in the back cover which acts as a volt meter. In the case where it is assumed that the alternator has
stopped charging, remove the back cover and disconnect the wires. The LED will glow in one of the following colours:
RED – Below 11V; the alternator is faulty and must be replaced.
YELLOW – Below 12V; the alternator is faulty and must be replaced.
GREEN – Above 12V; the alternator is OK therefore the fault must be elsewhere.
The above instructions are located on a tag inserted in the back plate. “See Figure 2”
No internal relays for self-exciting. Self-excitation is achieved electronically and magnetically. This has an indefinite shelf
life.
An hour meter is located inside the back plate of the alternator. This may only be read by an authorised repairer and is
generally used to determine any warranty disputes.
3. Incorporated Volt Meter
4. Self-Exciting
5. Internal Hour Meter
-
Page 5 of 7 Members: M. Lo Giudice; G. Lo Giudice;
MAE MANUFACTURERS cc MANUFACTURERS OF THE MAE FLAMEPROOF ALTERNATOR AND ELECTRICAL FLAMEPROOF EQUIPMENT
REG NO: CK 95/47371/23 VAT NO: 447 011 0034
Tel: +27 (11) 421 5551 Fax: +27 (11) 421 5618
E-mail: [email protected] / [email protected]
An innovated mounting has been designed to alleviate difficulty in replacing an existing alternator with the MAE
Alternator. With this bracket, the hardship of aligning the fan-belt has been removed. 3 types of brackets are available:
Fan- belt driven. “See Figure 5”
Hydraulic driven. “See Figure 6”
Fan-belt bas mount. “See Figure 7”
6. Mounting
-
Page 6 of 7 Members: M. Lo Giudice; G. Lo Giudice;
MAE MANUFACTURERS cc MANUFACTURERS OF THE MAE FLAMEPROOF ALTERNATOR AND ELECTRICAL FLAMEPROOF EQUIPMENT
REG NO: CK 95/47371/23 VAT NO: 447 011 0034
Tel: +27 (11) 421 5551 Fax: +27 (11) 421 5618
E-mail: [email protected] / [email protected]
This alternator has a variety of pulley combinations depending on the engine requirements. “See Figure 7”
Pulleys Dimensions
7. Pulleys
-
Page 7 of 7 Members: M. Lo Giudice; G. Lo Giudice;
MAE MANUFACTURERS cc MANUFACTURERS OF THE MAE FLAMEPROOF ALTERNATOR AND ELECTRICAL FLAMEPROOF EQUIPMENT
REG NO: CK 95/47371/23 VAT NO: 447 011 0034
Tel: +27 (11) 421 5551 Fax: +27 (11) 421 5618
E-mail: [email protected] / [email protected]
There is a choice of 2 cable entry covers:
Back Entry. “See Figure 8”
Side Entry. “See Figure 9”
This is a brushless alternator (less working parts). There is no need to open the enclosure to install the wire cables. It is
compact, making it easier for installation. There is no need for field servicing.
The alternator is approved by worldwide approvals:
EXPLOLABS (South Africa)
8. Cable Entry
Summary
Disclaimer The information in this specification is derived from the latest model available at the time of issue 1.0. While every
precaution has been taken to ensure the accuracy of the content, no responsibility can be accepted for any errors or
omissions nor any misinterpretation or misapplication. MAE has adopted a continuous product improvement policy
and therefore, specifications are subject to change without prior notice © September 2009 MAE all rights reserved.
mailto:[email protected]:[email protected]