14ACX 1.5-5 TON AIR CONDITIONERS AIR ... - hvac.com · AIR CONDITIONERS 14ACX MERIT ... Fin collars...

184
AIR CONDITIONERS 14ACX MERIT ® Series R-410A Bulletin No. 210740 June 2015 Supersedes May 2015 SEER up to 16.00 1.5 to 5 Tons Cooling Capacity - 17,900 to 59,000 Btuh 14 AC x – 024 - 230 A 02 Nominal SEER Unit Type AC = Air Conditioner Refrigerant X = R-410A Nominal Cooling Capacity 018 = 1.5 tons 024 = 2 tons 030 = 2.5 tons 036 = 3 tons 041 = 3.5 tons 042 = 3.5 tons 047 = 4 tons 048 = 4 tons 059 = 5 tons 060 = 5 tons Minor Revision Level Voltage 230 = 208/230V-1phase-60hz MODEL NUMBER IDENTIFICATION PRODUCT SPECIFICATIONS Ratings Revision Level (NOTE - 018-024-030-036-042 models only) Regional Standards – (dash) = All Regions or Southwest Region (dependent on size) S = North and South Regions

Transcript of 14ACX 1.5-5 TON AIR CONDITIONERS AIR ... - hvac.com · AIR CONDITIONERS 14ACX MERIT ... Fin collars...

  • A I R C O N D I T I O N E R S

    14ACXMERIT Series

    R-410A Bulletin No. 210740

    June 2015 Supersedes May 2015

    SEER up to 16.001.5 to 5 Tons

    Cooling Capacity - 17,900 to 59,000 Btuh

    14 AC x 024 - 230 A 02

    Nominal SEER

    Unit Type AC = Air Conditioner

    Refrigerant X = R-410A

    Nominal Cooling Capacity 018 = 1.5 tons 024 = 2 tons 030 = 2.5 tons 036 = 3 tons 041 = 3.5 tons 042 = 3.5 tons 047 = 4 tons 048 = 4 tons 059 = 5 tons 060 = 5 tons

    Minor Revision Level

    Voltage 230 = 208/230V-1phase-60hz

    MODEL NUMBER IDENTIFICATION

    P R O D U C T S P E C I F I C AT I O N S

    Ratings Revision Level (NOTE - 018-024-030-036-042 models only)

    Regional Standards (dash) = All Regions or Southwest Region (dependent on size)

    S = North and South Regions

    14ACX 1.5-5 TON AIR CONDITIONERS

  • 14ACX - 1.5 to 5 Ton Air Conditioner / Page 2

    WARRANTY

    Compressor - limited warranty for five years in residential installations and five years in non-residential installations.

    All other covered components - five years in residential installations and one year in non-residential installations.

    Note - Refer to Lennox Equipment Limited Warranty certificate included with unit for specific details.

    APPROVALSAHRI Certified to AHRI Standard 210/240-2008.Sound rated in Lennox reverberant sound test room in Accordance with test conditions included in AHRI Standard 270-2008.Tested in the Lennox Research Laboratory environmental test room.Rated According to U.S. Department of Energy (DOE) test procedures.Region specific models meet the minimum efficiency requirements for U.S DOE Federal Regional Standards in that area.Units and components within bonded for grounding to meet safety standards for servicing required by UL, NEC and CEC.Units are ETL certified for the U.S. and Canada.ISO 9001 Registered Manufacturing Quality System.

    APPLICATIONSSEER up to 16.00.1.5 through 5 ton.Single-phase power supply.Sound levels as low as 76 dB.Vertical air discharge allows concealment behind shrubs at grade level or out of sight on a roof.Matching add-on furnace indoor coils or air handlers provide a wide range of cooling capacities and applications. See AHRI System Matches.See Indoor Coils and Air Handlers sections for data.Units shipped completely factory assembled, piped and wired. Each unit test operated at the factory ensuring proper operation.Installer must set air conditioner, connect refrigerant lines and make electrical connections to complete job.For expanded ratings, see www.lennoxdavenet.com.

    REFRIGERATION SYSTEM

    R-410A RefrigerantNon-chlorine, ozone friendly, R-410A.Unit pre-charged with refrigerant.See Specification table.

    Outdoor Coil FanDirect drive fan moves large air volumes uniformly through entire condenser coil for high refrigerant cooling capacity.Vertical air discharge minimizes operating sounds and eliminates damage to lawn and shrubs.Fan motor has sleeve bearings (-018 through -048 and -060 models), ball bearings (-059 model) and is inherently protected.Motor totally enclosed for maximum protection from weather, dust and corrosion.Rain shield on motor provides additional protection from moisture.Louvered steel top fan guard furnished as standard.Fan service access accomplished by removal of top panel.

    High Pressure SwitchShuts off unit if abnormal operating conditions cause the discharge pressure to rise above setting.Protects compressor from excessive condensing pressure.Manual reset.Copper Tube/Enhanced Fin CoilLennox designed and fabricated coil.Ripple-edged aluminum fins.Copper tube construction.Lanced fins provide maximum exposure of fin surface to air stream resulting in excellent heat transfer.Fin collars grip tubing for maximum contact area.Flared shoulder tubing connections/silver soldering construction.Coil is factory tested under high pressure to ensure leakproof construction.Steel louvered panels provide complete coil protection.Panels can be completely removed for servicing.

    A

    B

    C

    B

    C

    D

    E

    F

    FEATURES

    CONTENTSAHRI System Matches - All Regions ......................... 11AHRI System Matches - North / South Region .......... 46AHRI System Matches - Southwest Region ............ 117Dimensions - Unit ........................................................ 8Electrical Data.............................................................. 6Features....................................................................... 2Fire Wiring ................................................................... 5Installation Clearances ................................................ 5Model Number Identification ........................................ 1Optional Accessories ................................................... 6Sound Data .................................................................. 9Specifications............................................................... 6

    http://www.lennoxdavenet.com

  • 14ACX - 1.5 to 5 Ton Air Conditioner / Page 3

    REFRIGERATION SYSTEM

    R-410A RefrigerantNon-chlorine, ozone friendly, R-410A.Unit pre-charged with refrigerant.See Specification table.

    Outdoor Coil FanDirect drive fan moves large air volumes uniformly through entire condenser coil for high refrigerant cooling capacity.Vertical air discharge minimizes operating sounds and eliminates damage to lawn and shrubs.Fan motor has sleeve bearings (-018 through -048 and -060 models), ball bearings (-059 model) and is inherently protected.Motor totally enclosed for maximum protection from weather, dust and corrosion.Rain shield on motor provides additional protection from moisture.Louvered steel top fan guard furnished as standard.Fan service access accomplished by removal of top panel.

    High Pressure SwitchShuts off unit if abnormal operating conditions cause the discharge pressure to rise above setting.Protects compressor from excessive condensing pressure.Manual reset.Copper Tube/Enhanced Fin CoilLennox designed and fabricated coil.Ripple-edged aluminum fins.Copper tube construction.Lanced fins provide maximum exposure of fin surface to air stream resulting in excellent heat transfer.Fin collars grip tubing for maximum contact area.Flared shoulder tubing connections/silver soldering construction.Coil is factory tested under high pressure to ensure leakproof construction.Steel louvered panels provide complete coil protection.Panels can be completely removed for servicing.

    A

    B

    C

    Refrigerant Flow ControlUnits applicable to expansion valve systems or RFC systems when matched with specific indoor coils.

    RFCIV:Accurately meters refrigerant in system.Refrigerant control is accomplished by exact sizing of refrigerant metering orifice.The principle involves matching indoor coil with proper bore size of orifice in metering device.Equalizes pressure shortly after compressor stops, unit starts unloaded, eliminating need for additional controls.Furnished with air conditioner.

    High Capacity Liquid Line DrierFurnished with unit for field installation.Approved for use with R-410A systems.Traps any moisture or dirt that could contaminate the refrigerant system.

    Optional Accessories

    Expansion Valve KitsMust be ordered extra and field installed on certain indoor units. See Refrigerant Metering Devices table.Chatleff-style fittings.

    FreezestatInstalls on or near the vapor line of the indoor coil or on the suction line.Senses suction line temperature and cycles the compressor off when suction line temperature falls below its setpoint.Opens at 29F and closes at 58F.

    Loss of Charge Switch KitHelps protect the compressor from damage due low refrigerant charge conditions.SPST, normally-closed switch, automatic reset switch mounted on liquid line.

    Refrigerant Line KitsRefrigerant lines (suction & liquid) are shipped refrigeration clean. Lines are cleaned, dried, pressurized and sealed at factory.Suction line fully insulated.Lines are stubbed at both ends.Not available for -059-060 models. Must be field fabricated.

    ORING

    RFCIV METERING SYSTEMRFCIV

    ORIFICE

    ORIFICE BODY(On Coil)

    SEALNUT SWEAT

    CONNECTION

    LIQUIDLINE

    LIQUIDLINE SCREEN

    FEATURES

  • 14ACX - 1.5 to 5 Ton Air Conditioner / Page 4

    COMPRESSORScroll CompressorCompressor features high efficiency with uniform suction flow, constant discharge flow, high volumetric efficiency and quiet operation.Compressor consists of two involute spiral scrolls matched together to generate a series of crescent shaped gas pockets between them.During compression, one scroll remains stationary while the other scroll orbits around it.Gas is drawn into the outer pocket, the pocket is sealed as the scroll rotates.As the spiral movement continues, gas pockets are pushed to the center of the scrolls. Volume between the pockets is simultaneously reduced.When the pocket reaches the center, gas is now at high pressure and is forced out of a port located in the center of the fixed scrolls.During compression, several pockets are compressed simultaneously resulting in a smooth continuous compression cycle.Continuous flank contact, maintained by centrifugal force, minimizes gas leakage and maximizes efficiency.Scroll compressor is tolerant to the effects of slugging and contaminants. If this occurs, scrolls separate, allowing liquid or contaminants to to be worked toward the center and discharged.Low gas pulses during compression reduces operational sound levels.Compressor motor is internally protected from excessive current and temperature.Compressor is installed in the unit on resilient rubber mounts for vibration free operation.

    Compressor Crankcase Heater (-041, -047, -048, -059 & -060 Models)Protects against refrigerant migration that can occur during low ambient operation.

    Optional Accessories

    Compressor Crankcase Heater (Optional for 018-024-030-036-042)Protects against refrigerant migration that can occur during low ambient operation.

    Compressor Sound CoverA reinforced vinyl compressor cover containing a 1-1/2 inch thick batt of fiberglass insulation.All open edges are sealed with a one-inch wide hook and loop fastening tape.

    D

    CONTROLS

    Optional Accessories

    Compressor Hard Start KitSingle-phase units are equipped with a PSC compressor motor. This type of motor normally doesnt need a potential relay and start capacitor.In conditions such as low voltage, this kit may be required to increase the compressor starting torque.

    Compressor Low Ambient Cut-Off SwitchNon-adjustable switch (low ambient cut-out) prevents compressor operation when outdoor temperature is below 35F.

    Compressor Time-Off ControlKit prevents compressor short-cycling and allows time for suction and discharge pressure to equalize.Permits compressor start-up in an unloaded condition.Automatic reset with 5 minute delay between compressor shut-off and start-up.

    Indoor Blower Off Delay RelayDelays the indoor blower-off time during the cooling cycle.See AHRI System Matches for usage.

    Low Ambient KitAir conditioners operate satisfactorily in the cooling mode down to 45F outdoor air temperature without any additional controls.Kit can be added in the field enabling unit to operate properly down to 30F in the cooling mode.Crankcase heater and freezestat should be installed on compressors equipped with a Low Ambient Kit.A compressor lock-out thermostat should be added to terminate compressor operation below recommended operation conditions.

    ThermostatThermostat not furnished with unit. See Thermostat bulletins in Controls Section and Lennox Price Book.

    FEATURES

  • 14ACX - 1.5 to 5 Ton Air Conditioner / Page 5

    CABINETHeavy gauge steel cabinet with five station metal wash process.Louvered heavy gauge steel panels surround unit on all four sides to prevent damage to the coil.Powder paint finish provides superior rust and corrosion protection.Control box is conveniently located with all controls factory wired.Corner patch plate allows access to compressor components.Drainage holes are provided in base section for moisture removal.

    PermaGuard Unit BaseDurable zinc-coated base section resists rust and corrosion.

    Refrigerant Line Connections, Electrical Inlets, Service ValvesSweat connection suction and liquid lines are located on corner of unit cabinet.Fully serviceable brass service valves prevent corrosion and provide access to refrigerant system. Suction valve can be fully shut off, while liquid valve may be front seated to manage refrigerant charge while servicing system.Refrigerant line connections and field wiring inlets are located in one central area of cabinet for easy access. See dimension drawing.

    E

    F

    B

    DISCONNECTSWITCH

    (By Others)

    LENNOXAIR

    CONDITIONER

    LENNOXHEATING UNIT

    ORAIR HANDLER

    UNIT

    DISCONNECTSWITCH

    (By Others)THERMOSTAT

    (Optional)

    C

    DA

    SeeNOTES

    See NOTES

    See NOTES

    SeeNOTES

    CONTROLBOX

    A - Two Wire PowerB - Two Wire Power (See Electrical Data)C - Two Wire Low Voltage (18 ga. minimum)D - Four Wire Low Voltage (Electro-Mechanical) 18 ga. minimum.

    Five Wire Low Voltage (Electronic) 18 ga. minimum

    NOTE - Field Wiring Not FurnishedAll wiring must conform to NEC or CEC and local electrical codes.

    NOTES:Service clearance of 30 in. (762 mm) must be maintained on

    one of the sides adjacent to the control box.Clearance to one of the other three sides must be

    36 in. (914 mm)Clearance to one of the remaining two sides may be

    12 in. (305 mm) and the final side may be 6 in. (152 mm).A clearance of 24 in. must be maintained between two units.48 in. (1219 mm) clearance required on top of unit.

    Optional Accessories

    Mounting BaseProvides permanent foundation for outdoor units.High density polyethylene structural material is lightweight, sturdy, sound absorbing and will withstand the rigors of the sun, heat, cold, moisture, oil and refrigerant. Will not mildew or rot.Can be shipped singly or in packages of 6 to a carton.

    Unit Stand-Off KitBlack high density polyethylene feet are available to raise unit off of mounting surface away from damaging moisture.Four feet are furnished per order number.

    FEATURES

    FIRE WIRING INSTALLATION CLEARANCES - IN. (MM)

  • 14ACX - 1.5 to 5 Ton Air Conditioner / Page 6

    SPECIFICATIONSGeneral Data

    Model No. All Regions - - - - - - - - - - - - 14ACX-041North / South Regions 14ACXS018 14ACXS024 14ACXS030 14ACXS036 - - -

    Southwest Region 14ACX-018 14ACX-024 14ACX-030 14ACX-036 - - -Nominal Tonnage 1.5 2 2.5 3 3.5

    Connections (sweat)

    Liquid line o.d. - in. 3/8 3/8 3/8 3/8 3/8 Suction line o.d. - in. 3/4 3/4 3/4 7/8 7/8

    1 Refrigerant (R-410A) furnished 4 lbs. 13 oz. 5 lbs. 6 oz. 6 lbs. 11 oz. 6 lbs. 11 oz. 10 lbs. 1 oz.Outdoor Coil

    Net face area sq. ft.

    Outer coil 13.22 16 21 21 21Inner coil - - - - - - - - - - - - 20.25

    Tube diameter - in. 5/16 5/16 5/16 5/16 5/16Number of rows 1 1 1 1 2

    Fins per inch 26 26 26 26 22Outdoor Fan

    Diameter - in. 18 22 22 22 22Number of blades 3 3 3 3 4

    Motor hp 1/10 1/6 1/6 1/6 1/4 Cfm 2290 3160 3160 3160 3600

    Rpm 1075 825 825 825 825Watts 160 215 215 215 310

    Shipping Data - lbs. 1 package 138 158 171 177 209ELECTRICAL DATA

    Line voltage data - 60 hz - 1ph 208/230V 208/230V 208/230V 208/230V 208/230V2 Maximum overcurrent protection (amps) 20 25 25 30 35

    3 Minimum circuit ampacity 12.4 15.0 17.1 18.6 22.6Compressor Rated load amps 9.4 11.2 12.9 14.1 16.7

    Locked rotor amps 56.6 60.8 64 77 79Power factor 0.96 0.97 0.98 0.98 0.97

    Condenser Fan Motor

    Full load amps 0.7 1.0 1.0 1.0 1.7Locked rotor amps 1.3 1.9 1.9 1.9 3.2

    OPTIONAL ACCESSORIES - ORDER SEPARATELYCompressor Crankcase Heater 93M04

    Factory Compressor Hard Start Kit 10J42

    88M91 Compressor Low Ambient Cut-Off Switch 45F08 Compressor Sound Cover 69J03 Compressor Time-Off Control 47J27 Freezestat 3/8 in. tubing 93G35

    5/8 in. tubing 50A93 Indoor Blower Off Delay Relay 58M81 Loss of Charge Switch Kit 84M23 4 Low Ambient Kit (Fan Cycling) 34M72 Mounting Base 69J06

    69J07 Refrigerant Line Sets

    L15-41-20, L15-41-30, L15-41-40, L15-41-50

    L15-65-30, L15-65-40, L15-65-50

    Unit Stand-Off Kit 94J45 NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage.1 Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the Installation Instructions for information about line set length and

    additional refrigerant charge required.2 HACR type circuit breaker or fuse.3 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.4 Crankcase Heater and Freezestat are recommended with Low Ambient Kit.

  • 14ACX - 1.5 to 5 Ton Air Conditioner / Page 7

    SPECIFICATIONSGeneral Data

    Model No. All Regions - - - 14ACX-047 14ACX-048 14ACX-059 14ACX-060North / South Regions 14ACXS042 - - - - - - - - - - - -

    Southwest Region 14ACX-042 - - - - - - - - - - - -Nominal Tonnage 3.5 4 4 5 5

    Connections (sweat)

    Liquid line o.d. - in. 3/8 3/8 3/8 3/8 3/8Suction line o.d. - in. 7/8 7/8 7/8 1-1/8 1-1/8

    1 Refrigerant (R-410A) furnished 8 lbs. 10 oz. 11 lbs. 3 oz. 10 lbs. 8 oz. 11 lbs. 2 oz. 12 lbs. 0 oz.Outdoor Coil

    Net face area sq. ft.

    Outer coil 18.67 22 21 24.94 22Inner coil 17.96 21.33 20.25 24.14 21.33

    Tube diameter - in. 5/16 5/16 5/16 5/16 5/16Number of rows 2 2 2 2 2

    Fins per inch 22 22 22 22 22Outdoor Fan

    Diameter - in. 22 26 22 26 26Number of blades 4 4 4 4 4

    Motor hp 1/4 1/3 1/4 1/3 1/3Cfm 3500 4400 3600 4400 4400

    Rpm 825 825 825 825 825Watts 310 310 310 310 310

    Shipping Data - lbs. 1 package 208 250 228 266 253ELECTRICAL DATA

    Line voltage data - 60 hz - 1ph 208/230V 208/230V 208/230V 208/230V 208/230V2 Maximum overcurrent protection (amps) 40 45 45 50 60

    3 Minimum circuit ampacity 24.1 26.7 26.7 34.1 34.8Compressor Rated load amps 17.9 19.9 20 25 26.4

    Locked rotor amps 112 109 99 134 134Power factor 0.94 0.97 0.99 0.98 0.98

    Condenser Fan Motor

    Full load amps 1.7 1.8 1.7 2.8 1.8Locked rotor amps 3.2 2.9 3.2 - - - 2.9

    OPTIONAL ACCESSORIES - ORDER SEPARATELYCompressor Crankcase Heater 93M04

    Factory Compressor Hard Start Kit 88M91 Compressor Low Ambient Cut-Off Switch 45F08 Compressor Sound Cover 69J03 Compressor Time-Off Control 47J27 Freezestat 3/8 in. tubing 93G35

    5/8 in. tubing 50A93 Indoor Blower Off Delay Relay 58M81 Loss of Charge Switch Kit 84M23 4 Low Ambient Kit (Fan Cycling) 34M72

    68M04 Mounting Base 69J07 Refrigerant Line Sets

    L15-65-30, L15-65-40, L15-65-50

    Field Fabricate Unit Stand-Off Kit 94J45 NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage.1 Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the Installation Instructions for information about line set length and

    additional refrigerant charge required.2 HACR type circuit breaker or fuse.3 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.4 Crankcase Heater and Freezestat are recommended with Low Ambient Kit.

  • 14ACX - 1.5 to 5 Ton Air Conditioner / Page 8

    SUCTION AND

    C

    SIDE VIEW

    DISCHARGE AIR

    SIDE VIEW

    A

    B

    A

    LIQUID LINECONNECTION

    OUTDOORCOIL FAN

    COMPRESSOR

    OPTIONAL UNITSTANDOFF KIT (4)(FIELD INSTALLED)

    4-3/8

    INLET

    AIR

    INLET

    AIR

    TOP VIEW

    INLET AIR

    INLET AIR

    SUCTION LINECONNECTION

    LIQUID LINECONNECTION 6-3/8

    (162)

    TOP VIEW BASE SECTION

    COMPRESSOR

    COIL DRAIN OUTLETS(Around perimeter of base)

    OPTIONAL UNITSTAND-OFF KIT (4)

    (Field Installed)

    (111)

    4-3/84-3/8

    4-3/8 4-3/8

    6-3/8(162)

    (111) (111)

    (111) (111)

    4-3/8(111)

    2 (51)

    3/4 (19)

    2-3/4 (70)

    ELECTRICALINLETS

    ModelA B C

    inches mm inches mm inches mm018 24-1/4 616 29-1/4 743 28-1/2 724024 28-1/4 718 29-1/4 743 28-1/2 724030 28-1/4 718 37-1/4 946 36-1/2 927036 28-1/4 718 37-1/4 946 36-1/2 927041 28-1/4 718 37-1/4 946 36-1/2 927042 28-1/4 718 33-1/4 845 32-1/2 826047 32-1/4 817 33-1/4 845 32-1/2 826048 28-1/4 718 37-1/4 946 36-1/2 927059 32-1/4 817 37-1/4 946 36-1/2 927060 32-1/4 817 33-1/4 845 32-1/2 826

    DIMENSIONS - UNIT - INCHES (MM)

  • 14ACX - 1.5 to 5 Ton Air Conditioner / Page 9

    SOUND DATA

    1 Unit Model

    Octave Band Linear Sound Power Levels dB, re 10-12 Watts Center Frequency - HZ

    1 Sound Rating Number (dB)

    125 250 500 1000 2000 4000 8000018 69.5 70.5 71.0 71.0 69.0 63.5 57.5 76024 69.5 72.0 70.5 70.5 67.5 62.5 57.5 76030 72.5 74.0 74.0 72.0 67.5 61.5 56.5 76036 73.5 75.0 74.0 72.5 67.5 62.5 56.5 76041 76.5 74.0 73.5 73.5 70.0 62.5 58.5 78042 73.5 75.5 74.5 73.5 70.5 64.0 58.5 78047 76.5 77.5 77.5 73.5 69.0 63.5 60.5 80048 76.5 74.0 73.5 73.5 70.0 62.5 58.5 78059 79.5 76.5 76.5 72.5 68.0 63.0 60.5 78060 76.5 77.5 77.5 73.5 69.0 63.5 60.5 80NOTE - the octave sound power data does not include tonal correction.1 Tested according to AHRI Standard 270-2008 test conditions.

  • 14ACX - 1.5 to 5 Ton Air Conditioner / Page 10

    AHRI STANDARD 210/240

    Cooling or heating capacities are net values, including the effects of blower motor heat, and do not include supplementary heat. Power input is the total power input to the compressor(s) and fan(s), plus any controls and other items required as part of the system for normal operation.Units which do not have an indoor air-circulating blower furnished as part of the model, i.e., split system with indoor coil only, is established by subtracting from the total cooling capacity 1250 Btu/h per 1,000 cfm, and by adding the same amount to the heating capacity. Total power input for both heating and cooling is increased by 365 W per 1,000 cfm of indoor air circulated.

    TXV/ORIFICE USAGEUse this table for C33, C35, CH23, CH33, CH35 and CR33 Field Installed TXV/Orifice Match-Ups.Outdoor Unit Model No.

    Refrigerant Metering Orifice (RFC)

    Thermal Expansion Valve (TXV)Order No. Orifice Size

    14ACX(-)(S)018 10W94 0.052 12J1814ACX(-)(S)024 97M75 0.057 12J1814ACX(-)(S)030 97M76 0.063 12J1814ACX(-)(S)036 11W02 0.073 12J1914ACX-041 N/A N/A 12J2014ACX(-)(S)042 97M78 0.076 12J2014ACX-047 N/A N/A 12J2014ACX-048 N/A N/A 12J2014ACX-059 N/A N/A 12J2014ACX-060 N/A N/A 12J20CX34 and CX35 upflow coils and all Lennox air handlers are shipped with a factory installed TXV. In most cases, no change out of the valve is needed.If a change out is required it will be listed in the TXV SUBSTITUTIONS table. The correct TXV must be ordered separately and field installed.C33, C35, CH33 and CH35 coils - Use the orifice shipped with the outdoor unit or replace the factory installed orifice with the expansion valve listed.CR33 and CH23 coils - Use the orifice shipped with the outdoor unit or use the expansion valve listed.

    MOST POPULAR MATCHESOutdoor Unit Model No.

    Indoor Unit Model No

    14ACX(-)(S)018 CX34-2514ACX(-)(S)024 CX34-2514ACX(-)(S)030 CX34-3114ACX(-)(S)036 CX34-3814ACX-041 CX34-4914ACX(-)(S)042 CX34-4914ACX-047 CX34-62C14ACX-048 CX34-62C14ACX-059 CX34-62C14ACX-060 CX34-62C

    *TXV SUBSTITUTIONSUse this table to determine if the factory installed TXV in the indoor unit needs to be replaced.Outdoor Unit Model No. Indoor Coil

    Factory TXV

    Replacement TXV

    14ACX(-)(S)030 CX34-42 12J20 12J1814ACX(-)(S)030 CX34-43 12J20 12J1814ACX(-)(S)030 CX35-48 12J20 12J1814ACX(-)(S)036 CX34-31 12J18 12J19

    * CX34 and CX35 coils - The factory installed expansion valve must be replaced with the expansion valve listed (ordered separately). If the combination is not listed above, the factory installed TXV is used.

  • 14ACX - 1.5 to 5 Ton Air Conditioner / Page 11

    AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

    Expansion Device Capacity SEER EER

    Coil or Air Handler Furnace

    AHRI Reference

    14ACX-041-230 TXV 38,500 15.50 13.20 C33-38 EL180UH090E48B 573510714ACX-041-230 TXV 38,500 15.50 13.20 C33-38 EL180UH090XE48B 573707114ACX-041-230 TXV 37,000 14.70 12.70 C33-42 EL180UH090E48B 573513614ACX-041-230 TXV 37,000 14.70 12.70 C33-42 EL180UH090XE48B 573712214ACX-041-230 TXV 39,000 15.50 13.20 C33-43 EL180UH090E48B 573510914ACX-041-230 TXV 39,000 16.00 13.50 C33-43 EL180UH090E60C 573600814ACX-041-230 TXV 39,000 15.50 13.20 C33-43 EL180UH090XE48B 573707314ACX-041-230 TXV 39,000 16.00 13.50 C33-43 EL180UH110E60C 573783214ACX-041-230 TXV 39,000 16.00 13.50 C33-43 EL180UH110XE60C 573890314ACX-041-230 TXV 39,000 15.70 13.50 C33-43 EL195UH090XE48C 469385014ACX-041-230 TXV 39,000 15.50 13.20 C33-43 EL195UH110XE60C 469386414ACX-041-230 TXV 39,000 15.70 13.50 C33-43 EL296UH090XE48C 564728614ACX-041-230 TXV 39,000 15.50 13.20 C33-43 EL296UH110XE60C 564724914ACX-041-230 TXV 39,000 15.70 13.50 C33-43 EL296UH110XV48C 568512914ACX-041-230 TXV 37,800 14.70 12.50 C33-43 SL280UH070V36A 507731614ACX-041-230 TXV 39,000 16.00 13.00 C33-43 SL280UH090V60C 386909314ACX-041-230 TXV 39,000 16.00 13.00 C33-43 SL280UH090XV60C 423523514ACX-041-230 TXV 39,000 16.00 13.00 C33-43 SL280UH110V60C 386909414ACX-041-230 TXV 39,000 16.00 13.00 C33-43 SL280UH110XV60C 404007014ACX-041-230 TXV 38,000 15.20 13.00 C33-48 EL180UH090E48B 573511114ACX-041-230 TXV 38,500 15.50 13.20 C33-48 EL180UH090E60C 573601014ACX-041-230 TXV 38,000 15.20 13.00 C33-48 EL180UH090XE48B 573707414ACX-041-230 TXV 38,000 15.50 13.20 C33-48 EL180UH110E60C 573783414ACX-041-230 TXV 38,000 15.50 13.20 C33-48 EL180UH110XE60C 573890414ACX-041-230 TXV 37,800 15.20 13.00 C33-48 EL195UH090XE48C 469385114ACX-041-230 TXV 38,500 15.20 13.20 C33-48 EL195UH110XE60C 469386514ACX-041-230 TXV 37,800 15.20 13.00 C33-48 EL296UH090XE48C 564723614ACX-041-230 TXV 38,500 15.20 13.20 C33-48 EL296UH110XE60C 564725014ACX-041-230 TXV 38,500 15.20 13.20 C33-48 EL296UH110XV48C 568513014ACX-041-230 TXV 38,500 14.50 12.50 C33-49 386909614ACX-041-230 TXV 39,500 16.00 13.00 C33-49 EL180UH090E60C 573601214ACX-041-230 TXV 39,500 16.00 13.00 C33-49 EL180UH110E60C 573783614ACX-041-230 TXV 39,500 16.00 13.00 C33-49 EL180UH110XE60C 573891214ACX-041-230 TXV 39,500 16.00 13.50 C33-49 EL195UH090XE48C 469385214ACX-041-230 TXV 39,500 16.00 13.50 C33-49 EL195UH110XE60C 469386614ACX-041-230 TXV 39,500 16.00 13.50 C33-49 EL296UH090XE48C 564723714ACX-041-230 TXV 39,500 15.50 12.50 C33-49 EL296UH090XV48C 749282214ACX-041-230 TXV 39,500 16.00 13.50 C33-49 EL296UH110XE60C 564725114ACX-041-230 TXV 39,500 16.00 13.50 C33-49 EL296UH110XV48C 568513114ACX-041-230 TXV 38,500 15.70 13.20 C33-50/60C EL180UH090E60C 573601414ACX-041-230 TXV 38,500 15.70 13.20 C33-50/60C EL180UH110E60C 573783814ACX-041-230 TXV 38,500 15.70 13.20 C33-50/60C EL180UH110XE60C 573891514ACX-041-230 TXV 38,500 15.50 13.20 C33-50/60C EL195UH090XE48C 469385314ACX-041-230 TXV 38,500 15.50 13.00 C33-50/60C EL195UH110XE60C 469386714ACX-041-230 TXV 38,500 15.50 13.20 C33-50/60C EL296UH090XE48C 564723814ACX-041-230 TXV 38,500 15.50 13.00 C33-50/60C EL296UH110XE60C 564725214ACX-041-230 TXV 38,500 15.50 13.20 C33-50/60C EL296UH110XV48C 568513214ACX-041-230 TXV 40,000 16.00 13.00 C33-62C EL180UH090E60C 573601614ACX-041-230 TXV 40,000 16.00 13.00 C33-62C EL180UH110E60C 5737839NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95F outdoor air temperature, 80F db / 67F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

    http://www.ahridirectory.org

  • 14ACX - 1.5 to 5 Ton Air Conditioner / Page 12

    AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

    Expansion Device Capacity SEER EER

    Coil or Air Handler Furnace

    AHRI Reference

    14ACX-041-230 TXV 40,000 16.00 13.00 C33-62C EL180UH110XE60C 573891614ACX-041-230 TXV 40,000 16.00 13.50 C33-62C EL195UH090XE48C 469385414ACX-041-230 TXV 40,500 16.00 13.50 C33-62C EL195UH110XE60C 469386814ACX-041-230 TXV 40,000 16.00 13.50 C33-62C EL296UH090XE48C 564723914ACX-041-230 TXV 40,500 16.00 13.50 C33-62C EL296UH110XE60C 564725314ACX-041-230 TXV 40,000 16.00 13.00 C33-62C SLP98UH090XV48C 576728914ACX-041-230 TXV 38,500 15.50 12.50 C35-36B EL180UH090E48B 826793314ACX-041-230 TXV 38,500 15.50 12.50 C35-36B EL180UH090XE48B 826793214ACX-041-230 TXV 37,800 14.50 12.20 C35-48B 826793414ACX-041-230 TXV 38,500 15.50 12.50 C35-48B EL180UH090E48B 826794014ACX-041-230 TXV 38,500 15.50 12.50 C35-48B EL180UH090XE48B 826793814ACX-041-230 TXV 37,800 14.50 12.20 C35-48C 826793514ACX-041-230 TXV 38,500 16.00 13.00 C35-48C EL180UH090E60C 826793914ACX-041-230 TXV 38,500 16.00 13.00 C35-48C EL180UH110E60C 826794114ACX-041-230 TXV 38,500 16.00 13.00 C35-48C EL180UH110XE60C 826794214ACX-041-230 TXV 38,500 15.50 12.50 C35-48C EL195UH090XE48C 826794614ACX-041-230 TXV 38,500 15.50 12.50 C35-48C EL195UH110XE60C 826794514ACX-041-230 TXV 38,500 15.50 12.50 C35-48C EL296UH090XE48C 826794414ACX-041-230 TXV 38,500 15.50 12.50 C35-48C EL296UH110XE60C 826794314ACX-041-230 TXV 39,000 16.00 13.00 C35-48C SL280UH090V60C 826793614ACX-041-230 TXV 39,000 16.00 13.00 C35-48C SL280UH090XV60C 826794714ACX-041-230 TXV 38,500 15.50 12.50 C35-48C SL280UH110V60C 826793714ACX-041-230 TXV 38,500 15.50 12.50 C35-48C SL280UH110XV60C 826794814ACX-041-230 TXV 38,500 14.70 12.50 C35-49C 826794914ACX-041-230 TXV 39,000 16.00 13.00 C35-49C EL180UH090E60C 826795014ACX-041-230 TXV 39,000 16.00 13.00 C35-49C EL180UH110E60C 826795114ACX-041-230 TXV 39,000 16.00 13.00 C35-49C EL180UH110XE60C 826795214ACX-041-230 TXV 38,500 16.00 13.00 C35-49C EL195UH090XE48C 826795614ACX-041-230 TXV 39,000 15.50 12.50 C35-49C EL195UH110XE60C 826795514ACX-041-230 TXV 38,500 16.00 13.00 C35-49C EL296UH090XE48C 826795414ACX-041-230 TXV 39,000 15.50 12.50 C35-49C EL296UH110XE60C 826795314ACX-041-230 TXV 38,000 15.50 12.50 C35-50/60C EL180UH090E60C 826795714ACX-041-230 TXV 38,000 15.50 12.50 C35-50/60C EL180UH110E60C 826795814ACX-041-230 TXV 38,000 15.50 12.50 C35-50/60C EL180UH110XE60C 826795914ACX-041-230 TXV 38,000 15.50 12.50 C35-50/60C EL195UH090XE48C 826796314ACX-041-230 TXV 38,500 15.50 12.50 C35-50/60C EL195UH110XE60C 826796214ACX-041-230 TXV 38,000 15.50 12.50 C35-50/60C EL296UH090XE48C 826796114ACX-041-230 TXV 38,500 15.50 12.50 C35-50/60C EL296UH110XE60C 826796014ACX-041-230 TXV 40,000 16.00 13.00 C35-60C EL180UH090E60C 826796514ACX-041-230 TXV 40,000 16.00 13.00 C35-60C EL180UH110E60C 826796614ACX-041-230 TXV 40,000 16.00 13.00 C35-60C EL180UH110XE60C 826796714ACX-041-230 TXV 39,500 16.00 13.00 C35-60C EL195UH090XE48C 826797114ACX-041-230 TXV 40,000 16.00 13.00 C35-60C EL195UH110XE60C 826797014ACX-041-230 TXV 39,500 16.00 13.00 C35-60C EL296UH090XE48C 826796914ACX-041-230 TXV 40,000 16.00 13.00 C35-60C EL296UH110XE60C 826796814ACX-041-230 TXV 40,000 16.00 13.00 C35-60C SLP98UH090XV48C 826796414ACX-041-230 TXV 38,000 14.50 12.50 CBX25UH-042 573278714ACX-041-230 TXV 39,500 15.20 13.00 CBX25UH-048 573278814ACX-041-230 TXV 39,000 16.00 13.50 CBX25UHV-042 6970129NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95F outdoor air temperature, 80F db / 67F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

    http://www.ahridirectory.org

  • 14ACX - 1.5 to 5 Ton Air Conditioner / Page 13

    AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

    Expansion Device Capacity SEER EER

    Coil or Air Handler Furnace

    AHRI Reference

    14ACX-041-230 TXV 40,000 16.00 14.00 CBX25UHV-048 697013014ACX-041-230 TXV 39,000 16.00 13.00 CBX27UH-048 386909714ACX-041-230 TXV 39,500 16.00 13.00 CBX32MV-048 386909814ACX-041-230 TXV 39,000 16.00 13.00 CBX40UHV-048 386909914ACX-041-230 TXV 37,600 15.50 13.00 CH23-51 EL180UH090E60C 573659614ACX-041-230 TXV 37,400 15.20 13.00 CH23-51 EL296UH110XV48C 568514014ACX-041-230 TXV 37,200 15.50 13.00 CH23-51 SL280UH090V60C 551408014ACX-041-230 TXV 38,000 15.50 13.00 CH23-65 EL180UH090E60C 573659814ACX-041-230 TXV 37,600 15.50 13.00 CH23-65 SL280UH090V60C 551408214ACX-041-230 TXV 39,500 16.00 13.50 CH33-43 EL180UH090E48B 573509714ACX-041-230 TXV 39,000 16.00 13.50 CH33-43 EL180UH090E60C 573599114ACX-041-230 TXV 39,500 16.00 13.50 CH33-43 EL180UH090XE48B 573706114ACX-041-230 TXV 39,000 16.00 13.50 CH33-43 EL180UH110E60C 573781314ACX-041-230 TXV 39,000 16.00 13.50 CH33-43 EL180UH110XE60C 573887414ACX-041-230 TXV 39,000 15.00 12.70 CH33-43 EL296UH045XV36B 515307014ACX-041-230 TXV 39,000 15.70 13.00 CH33-43 EL296UH090XV36C 505718714ACX-041-230 TXV 39,000 15.70 13.00 CH33-43 EL296UH090XV48C 505718814ACX-041-230 TXV 39,000 15.70 13.00 CH33-43 EL296UH090XV60C 505718914ACX-041-230 TXV 38,500 16.00 13.00 CH33-43 EL296UH110XV60C 505719014ACX-041-230 TXV 39,500 15.70 13.00 CH33-43 SL280UH090V36B 425379514ACX-041-230 TXV 39,000 15.70 13.00 CH33-43 SLP98UH090XV36C 514045814ACX-041-230 TXV 39,000 15.70 13.00 CH33-43 SLP98UH090XV48C 514045914ACX-041-230 TXV 39,000 15.70 13.00 CH33-43 SLP98UH090XV60C 514046014ACX-041-230 TXV 38,500 16.00 13.00 CH33-43 SLP98UH110XV60C 514046114ACX-041-230 TXV 39,500 15.70 13.00 CH33-43B SL280UH090V48B 386910014ACX-041-230 TXV 39,500 15.70 13.00 CH33-43B SL280UH090XV48B 403852114ACX-041-230 TXV 39,000 15.70 13.00 CH33-43C EL195UH090XE48C 469385514ACX-041-230 TXV 38,500 15.70 13.00 CH33-43C EL195UH110XE60C 469403014ACX-041-230 TXV 39,000 15.70 13.00 CH33-43C EL296UH090XE48C 564724014ACX-041-230 TXV 38,500 15.70 13.00 CH33-43C EL296UH110XE60C 564728814ACX-041-230 TXV 39,000 15.70 13.50 CH33-43C EL296UH110XV48C 568513714ACX-041-230 TXV 39,500 16.00 13.00 CH33-43C SL280UH090V60C 386910414ACX-041-230 TXV 39,500 16.00 13.00 CH33-43C SL280UH090XV60C 423523614ACX-041-230 TXV 39,000 15.70 13.00 CH33-43C SL280UH110V60C 386910514ACX-041-230 TXV 39,000 15.70 13.00 CH33-43C SL280UH110XV60C 404007314ACX-041-230 TXV 38,500 15.50 13.20 CH33-44/48 EL180UH090E48B 573509814ACX-041-230 TXV 38,500 15.50 13.20 CH33-44/48 EL180UH090XE48B 573706314ACX-041-230 TXV 38,000 14.70 12.50 CH33-44/48 EL296UH045XV36B 515307114ACX-041-230 TXV 38,500 15.70 13.20 CH33-48 EL180UH090E60C 573599314ACX-041-230 TXV 38,500 15.70 13.20 CH33-48 EL180UH110E60C 573781514ACX-041-230 TXV 38,500 15.70 13.20 CH33-48 EL180UH110XE60C 573887514ACX-041-230 TXV 38,500 15.20 13.00 CH33-48 EL296UH090XV36C 505719114ACX-041-230 TXV 38,500 15.50 13.00 CH33-48 EL296UH090XV48C 505719214ACX-041-230 TXV 38,500 15.20 13.00 CH33-48 SLP98UH090XV36C 514051514ACX-041-230 TXV 38,500 15.50 13.00 CH33-48 SLP98UH090XV48C 514051614ACX-041-230 TXV 38,500 15.50 13.00 CH33-48C EL195UH090XE48C 469385614ACX-041-230 TXV 39,000 15.50 13.20 CH33-48C EL195UH110XE60C 469386914ACX-041-230 TXV 38,500 15.50 13.00 CH33-48C EL296UH090XE48C 564724114ACX-041-230 TXV 39,000 15.50 13.20 CH33-48C EL296UH110XE60C 5647254NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95F outdoor air temperature, 80F db / 67F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

    http://www.ahridirectory.org

  • 14ACX - 1.5 to 5 Ton Air Conditioner / Page 14

    AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

    Expansion Device Capacity SEER EER

    Coil or Air Handler Furnace

    AHRI Reference

    14ACX-041-230 TXV 39,000 15.50 13.20 CH33-48C EL296UH110XV48C 568513814ACX-041-230 TXV 39,500 16.00 13.50 CH33-49 EL180UH090E60C 573599514ACX-041-230 TXV 39,500 16.00 13.50 CH33-49 EL180UH110E60C 573781814ACX-041-230 TXV 39,500 16.00 13.50 CH33-49 EL180UH110XE60C 573887714ACX-041-230 TXV 39,000 15.70 13.50 CH33-49 EL195UH090XE48C 469385714ACX-041-230 TXV 39,500 15.70 13.50 CH33-49 EL195UH110XE60C 469387014ACX-041-230 TXV 39,000 15.70 13.50 CH33-49 EL296UH090XE48C 564724214ACX-041-230 TXV 39,500 15.70 13.50 CH33-49 EL296UH110XE60C 564725514ACX-041-230 TXV 39,000 14.50 12.50 CH33-50/60C 425379814ACX-041-230 TXV 39,000 15.70 13.50 CH33-50/60C EL180UH090E60C 579575014ACX-041-230 TXV 39,000 15.70 13.50 CH33-50/60C EL180UH110E60C 573782014ACX-041-230 TXV 39,000 15.70 13.50 CH33-50/60C EL180UH110XE60C 573887914ACX-041-230 TXV 39,000 15.70 13.50 CH33-50/60C EL195UH090XE48C 469385814ACX-041-230 TXV 39,500 15.70 13.50 CH33-50/60C EL195UH110XE60C 469387114ACX-041-230 TXV 39,000 15.70 13.50 CH33-50/60C EL296UH090XE48C 564724314ACX-041-230 TXV 39,500 15.70 13.50 CH33-50/60C EL296UH110XE60C 564725614ACX-041-230 TXV 39,500 15.70 13.50 CH33-50/60C EL296UH110XV48C 568513914ACX-041-230 TXV 39,000 14.50 12.50 CH35-42B 716335014ACX-041-230 TXV 39,500 16.00 13.00 CH35-42B EL180UH090E48B 716335314ACX-041-230 TXV 39,000 15.10 13.00 CH35-42B EL296UH045V36B 716335214ACX-041-230 TXV 39,500 15.50 13.00 CH35-42B SL280UH090V36B 716335414ACX-041-230 TXV 39,500 15.50 13.00 CH35-42B SL280UH090V48B 716335514ACX-041-230 TXV 39,000 15.10 13.00 CH35-42B SLP98UH070XV36B 716335614ACX-041-230 TXV 38,500 14.50 12.50 CH35-42C 716335114ACX-041-230 TXV 39,000 16.00 13.00 CH35-42C EL180UH090E60C 716336414ACX-041-230 TXV 39,000 16.00 13.00 CH35-42C EL180UH110E60C 716336514ACX-041-230 TXV 38,500 15.50 13.00 CH35-42C EL195UH090XE48C 716335714ACX-041-230 TXV 39,000 15.50 13.00 CH35-42C EL195UH110XE60C 716413814ACX-041-230 TXV 38,500 15.50 13.00 CH35-42C EL296UH090XE48C 716336114ACX-041-230 TXV 38,500 15.50 13.00 CH35-42C EL296UH090XV36C 716335814ACX-041-230 TXV 38,500 15.50 13.00 CH35-42C EL296UH090XV48C 716335914ACX-041-230 TXV 39,000 15.50 13.00 CH35-42C EL296UH090XV60C 716336014ACX-041-230 TXV 39,000 15.50 13.00 CH35-42C EL296UH110XE60C 716414014ACX-041-230 TXV 39,000 15.50 13.00 CH35-42C EL296UH110XV48C 716336214ACX-041-230 TXV 39,000 16.00 13.00 CH35-42C EL296UH110XV60C 716336314ACX-041-230 TXV 39,000 16.00 13.00 CH35-42C SL280UH090V60C 716336714ACX-041-230 TXV 39,000 15.50 13.00 CH35-42C SL280UH110V60C 716336814ACX-041-230 TXV 38,500 15.50 13.00 CH35-42C SLP98UH090XV36C 716336914ACX-041-230 TXV 38,500 15.50 13.00 CH35-42C SLP98UH090XV48C 716337014ACX-041-230 TXV 39,000 15.50 13.00 CH35-42C SLP98UH090XV60C 716337114ACX-041-230 TXV 38,500 16.00 13.00 CH35-42C SLP98UH110XV60C 716337214ACX-041-230 TXV 38,000 14.50 12.50 CH35-48B 716337314ACX-041-230 TXV 38,500 15.50 13.00 CH35-48B EL180UH090E48B 716337614ACX-041-230 TXV 38,000 14.50 12.50 CH35-48B EL296UH045V36B 716337514ACX-041-230 TXV 38,000 14.50 12.50 CH35-48C 716337414ACX-041-230 TXV 38,500 15.50 13.00 CH35-48C EL180UH090E60C 716338314ACX-041-230 TXV 38,500 15.50 13.00 CH35-48C EL180UH110E60C 716338414ACX-041-230 TXV 38,000 15.50 13.00 CH35-48C EL195UH090XE48C 716337714ACX-041-230 TXV 38,500 15.50 13.00 CH35-48C EL195UH110XE60C 7163378NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95F outdoor air temperature, 80F db / 67F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

    http://www.ahridirectory.org

  • 14ACX - 1.5 to 5 Ton Air Conditioner / Page 15

    AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

    Expansion Device Capacity SEER EER

    Coil or Air Handler Furnace

    AHRI Reference

    14ACX-041-230 TXV 38,500 15.10 13.00 CH35-48C EL296UH090XV36C 716337914ACX-041-230 TXV 38,500 15.50 13.00 CH35-48C EL296UH090XV48C 716338014ACX-041-230 TXV 38,500 15.50 13.00 CH35-48C EL296UH110XE60C 716338214ACX-041-230 TXV 38,500 15.50 13.00 CH35-48C EL296UH110XV48C 716338114ACX-041-230 TXV 38,500 15.50 13.00 CH35-48C SL280UH090V60C 716338514ACX-041-230 TXV 38,500 15.50 13.00 CH35-48C SL280UH110V60C 716338614ACX-041-230 TXV 38,500 15.10 13.00 CH35-48C SLP98UH090XV36C 716338714ACX-041-230 TXV 38,500 15.50 13.00 CH35-48C SLP98UH090XV48C 716338814ACX-041-230 TXV 38,500 15.10 13.00 CH35-48C SLP98UH090XV60C 716413914ACX-041-230 TXV 38,500 15.50 13.00 CH35-48C SLP98UH110XV60C 716338914ACX-041-230 TXV 38,500 14.50 12.50 CH35-51C 716339014ACX-041-230 TXV 39,000 16.00 13.00 CH35-51C EL180UH090E60C 716339614ACX-041-230 TXV 39,000 16.00 13.00 CH35-51C EL180UH110E60C 716339714ACX-041-230 TXV 39,000 15.50 13.00 CH35-51C EL195UH090XE48C 716339114ACX-041-230 TXV 39,000 15.50 13.00 CH35-51C EL195UH110XE60C 716339214ACX-041-230 TXV 39,000 15.50 13.00 CH35-51C EL296UH090XE48C 716339314ACX-041-230 TXV 39,000 15.50 13.00 CH35-51C EL296UH110XE60C 716339514ACX-041-230 TXV 39,500 15.50 13.00 CH35-51C EL296UH110XV48C 716339414ACX-041-230 TXV 39,000 15.50 13.00 CH35-51C SLP98UH090XV36C 716339814ACX-041-230 TXV 39,000 15.50 13.00 CH35-51C SLP98UH090XV48C 716339914ACX-041-230 TXV 39,500 15.50 13.00 CH35-51C SLP98UH090XV60C 716340014ACX-041-230 TXV 39,500 15.50 13.00 CH35-51C SLP98UH110XV60C 716340114ACX-041-230 TXV 38,500 15.70 13.50 CR33-50/60 EL180DF110E60C 573350514ACX-041-230 TXV 38,000 15.50 13.00 CR33-50/60 EL195DF090XE48C 469384914ACX-041-230 TXV 38,500 15.50 13.20 CR33-50/60 EL195DF110XE60C 469402914ACX-041-230 TXV 38,000 15.50 13.00 CR33-50/60 EL296DF090XE48C 564728514ACX-041-230 TXV 36,400 15.50 13.00 CR33-50/60 EL296DF090XV60C 553048814ACX-041-230 TXV 38,500 15.50 13.20 CR33-50/60 EL296DF110XE60C 564728714ACX-041-230 TXV 38,500 15.00 12.50 CR33-50/60 EL296DF110XV60C 717668014ACX-041-230 TXV 38,500 16.00 13.00 CR33-50/60 SL280DF090V60C 386911414ACX-041-230 TXV 39,000 16.00 13.00 CR33-50/60 SL280DF110V60C 386916614ACX-041-230 TXV 38,500 15.50 13.20 CX34-38 EL180UH090E48B 573510114ACX-041-230 TXV 38,500 15.50 13.20 CX34-38 EL180UH090XE48B 573706514ACX-041-230 TXV 38,000 14.70 12.50 CX34-38 EL296UH045XV36B 515306614ACX-041-230 TXV 37,000 14.70 12.70 CX34-42 EL180UH090E48B 573513514ACX-041-230 TXV 37,000 14.70 12.70 CX34-42 EL180UH090XE48B 573712014ACX-041-230 TXV 39,000 15.50 13.20 CX34-43 EL180UH090E48B 573510214ACX-041-230 TXV 39,000 16.00 13.50 CX34-43 EL180UH090E60C 573599814ACX-041-230 TXV 39,000 15.50 13.20 CX34-43 EL180UH090XE48B 573706714ACX-041-230 TXV 39,000 16.00 13.50 CX34-43 EL180UH110E60C 573782214ACX-041-230 TXV 39,000 16.00 13.50 CX34-43 EL180UH110XE60C 573888014ACX-041-230 TXV 39,000 15.70 13.00 CX34-43 EL195UH090XE48C 469385914ACX-041-230 TXV 38,500 15.50 13.00 CX34-43 EL195UH110XE60C 469387214ACX-041-230 TXV 38,500 14.70 12.70 CX34-43 EL296UH045XV36B 515306814ACX-041-230 TXV 39,000 15.70 13.00 CX34-43 EL296UH090XE48C 564724414ACX-041-230 TXV 38,500 15.50 13.00 CX34-43 EL296UH090XV36C 505718314ACX-041-230 TXV 39,000 15.70 13.00 CX34-43 EL296UH090XV48C 505718414ACX-041-230 TXV 39,000 15.50 13.00 CX34-43 EL296UH090XV60C 505718514ACX-041-230 TXV 38,500 15.50 13.00 CX34-43 EL296UH110XE60C 5647257NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95F outdoor air temperature, 80F db / 67F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

    http://www.ahridirectory.org

  • 14ACX - 1.5 to 5 Ton Air Conditioner / Page 16

    AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

    Expansion Device Capacity SEER EER

    Coil or Air Handler Furnace

    AHRI Reference

    14ACX-041-230 TXV 39,000 15.70 13.50 CX34-43 EL296UH110XV48C 568513314ACX-041-230 TXV 38,500 16.00 13.50 CX34-43 EL296UH110XV60C 505718614ACX-041-230 TXV 39,000 16.00 13.00 CX34-43 SL280UH090V60C 386911814ACX-041-230 TXV 39,000 16.00 13.00 CX34-43 SL280UH090XV60C 423523714ACX-041-230 TXV 39,000 16.00 13.00 CX34-43 SL280UH110V60C 386911914ACX-041-230 TXV 39,000 16.00 13.00 CX34-43 SL280UH110XV60C 404007714ACX-041-230 TXV 38,500 15.50 13.00 CX34-43 SLP98UH090XV36C 514045414ACX-041-230 TXV 39,000 15.70 13.00 CX34-43 SLP98UH090XV48C 514045514ACX-041-230 TXV 39,000 15.50 13.00 CX34-43 SLP98UH090XV60C 514045614ACX-041-230 TXV 38,500 16.00 13.50 CX34-43 SLP98UH110XV60C 514045714ACX-041-230 TXV 38,000 15.20 13.00 CX34-44/48 EL180UH090E48B 573510514ACX-041-230 TXV 38,500 15.50 13.20 CX34-44/48 EL180UH090E60C 573599914ACX-041-230 TXV 38,000 15.20 13.00 CX34-44/48 EL180UH090XE48B 573706914ACX-041-230 TXV 38,000 15.50 13.20 CX34-44/48 EL180UH110E60C 573782314ACX-041-230 TXV 38,000 15.50 13.20 CX34-44/48 EL180UH110XE60C 573889514ACX-041-230 TXV 37,800 15.20 13.00 CX34-44/48 EL195UH090XE48C 469386014ACX-041-230 TXV 38,500 15.20 13.20 CX34-44/48 EL195UH110XE60C 469387314ACX-041-230 TXV 37,800 14.50 12.50 CX34-44/48 EL296UH045XV36B 515306914ACX-041-230 TXV 37,800 15.20 13.00 CX34-44/48 EL296UH090XE48C 564724514ACX-041-230 TXV 38,500 15.20 13.20 CX34-44/48 EL296UH110XE60C 564725814ACX-041-230 TXV 38,500 15.20 13.20 CX34-44/48 EL296UH110XV48C 568513414ACX-041-230 TXV 39,000 14.50 12.50 CX34-49 386912114ACX-041-230 TXV 39,500 16.00 13.00 CX34-49 EL180UH090E60C 573600114ACX-041-230 TXV 39,500 16.00 13.00 CX34-49 EL180UH110E60C 573782514ACX-041-230 TXV 39,500 16.00 13.00 CX34-49 EL180UH110XE60C 573889614ACX-041-230 TXV 39,500 16.00 13.50 CX34-49 EL195UH090XE48C 469386114ACX-041-230 TXV 39,500 16.00 13.00 CX34-49 EL195UH110XE60C 469387414ACX-041-230 TXV 39,500 16.00 13.50 CX34-49 EL296UH090XE48C 564724614ACX-041-230 TXV 39,500 15.50 12.50 CX34-49 EL296UH090XV48C 749282314ACX-041-230 TXV 39,500 16.00 13.00 CX34-49 EL296UH110XE60C 564725914ACX-041-230 TXV 39,500 16.00 13.50 CX34-49 EL296UH110XV48C 568513514ACX-041-230 TXV 39,500 16.00 13.00 CX34-49 EL296UH110XV60C 505719314ACX-041-230 TXV 40,000 16.00 13.00 CX34-49 SL280UH090V60C 425379914ACX-041-230 TXV 39,500 16.00 13.00 CX34-49 SL280UH110V60C 425380014ACX-041-230 TXV 39,500 16.00 13.00 CX34-49 SLP98UH110XV60C 514051714ACX-041-230 TXV 38,500 15.70 13.20 CX34-50/60C EL180UH090E60C 573600414ACX-041-230 TXV 38,500 15.70 13.20 CX34-50/60C EL180UH110E60C 573782814ACX-041-230 TXV 38,500 15.70 13.20 CX34-50/60C EL180UH110XE60C 573889914ACX-041-230 TXV 38,500 15.50 13.20 CX34-50/60C EL195UH090XE48C 469386214ACX-041-230 TXV 38,500 15.50 13.00 CX34-50/60C EL195UH110XE60C 469387514ACX-041-230 TXV 38,500 15.50 13.20 CX34-50/60C EL296UH090XE48C 564724714ACX-041-230 TXV 38,500 15.50 13.00 CX34-50/60C EL296UH110XE60C 564726014ACX-041-230 TXV 38,500 15.50 13.20 CX34-50/60C EL296UH110XV48C 568513614ACX-041-230 TXV 40,000 16.00 13.00 CX34-62C EL180UH090E60C 573600614ACX-041-230 TXV 40,000 16.00 13.00 CX34-62C EL180UH110E60C 573783014ACX-041-230 TXV 40,000 16.00 13.00 CX34-62C EL180UH110XE60C 573890014ACX-041-230 TXV 40,000 16.00 13.00 CX34-62C EL195UH090XE48C 469386314ACX-041-230 TXV 40,000 16.00 13.00 CX34-62C EL195UH110XE60C 469387614ACX-041-230 TXV 40,000 16.00 13.00 CX34-62C EL296UH090XE48C 5647248NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95F outdoor air temperature, 80F db / 67F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

    http://www.ahridirectory.org

  • 14ACX - 1.5 to 5 Ton Air Conditioner / Page 17

    AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

    Expansion Device Capacity SEER EER

    Coil or Air Handler Furnace

    AHRI Reference

    14ACX-041-230 TXV 40,000 16.00 13.00 CX34-62C EL296UH090XV36C 505719414ACX-041-230 TXV 40,000 16.00 13.00 CX34-62C EL296UH090XV48C 505719514ACX-041-230 TXV 40,000 16.00 13.00 CX34-62C EL296UH090XV60C 505719614ACX-041-230 TXV 40,000 16.00 13.00 CX34-62C EL296UH110XE60C 564726114ACX-041-230 TXV 40,000 16.00 13.00 CX34-62C EL296UH110XV60C 505719714ACX-041-230 TXV 40,000 16.00 13.00 CX34-62C SL280UH090V60C 425380214ACX-041-230 TXV 40,000 16.00 13.00 CX34-62C SL280UH110V60C 425380314ACX-041-230 TXV 40,000 16.00 13.00 CX34-62C SLP98UH090XV36C 514051814ACX-041-230 TXV 40,000 16.00 13.00 CX34-62C SLP98UH090XV48C 514051914ACX-041-230 TXV 40,000 16.00 13.00 CX34-62C SLP98UH090XV60C 514052014ACX-041-230 TXV 40,000 16.00 13.00 CX34-62C SLP98UH110XV60C 514052114ACX-041-230 TXV 38,500 15.50 12.50 CX35-36B EL180UH090E48B 826797314ACX-041-230 TXV 38,500 15.50 12.50 CX35-36B EL180UH090XE48B 826797214ACX-041-230 TXV 38,000 14.50 12.20 CX35-48B 826797414ACX-041-230 TXV 38,500 15.50 12.50 CX35-48B EL180UH090E48B 826797814ACX-041-230 TXV 38,500 15.50 12.50 CX35-48B EL180UH090XE48B 826797614ACX-041-230 TXV 38,000 14.50 12.20 CX35-48C 826797514ACX-041-230 TXV 38,500 16.00 13.00 CX35-48C EL180UH090E60C 826797714ACX-041-230 TXV 38,500 15.50 12.50 CX35-48C EL180UH110E60C 826797914ACX-041-230 TXV 38,500 16.00 13.00 CX35-48C EL180UH110XE60C 826798014ACX-041-230 TXV 38,500 15.50 12.50 CX35-48C EL195UH090XE48C 826799214ACX-041-230 TXV 38,500 15.50 12.50 CX35-48C EL195UH110XE60C 826799114ACX-041-230 TXV 38,500 15.50 12.50 CX35-48C EL296UH090XE48C 826798214ACX-041-230 TXV 38,500 15.50 12.50 CX35-48C EL296UH090XV36C 826798714ACX-041-230 TXV 38,500 15.50 12.50 CX35-48C EL296UH090XV48C 826798814ACX-041-230 TXV 38,500 15.50 12.50 CX35-48C EL296UH090XV60C 826798914ACX-041-230 TXV 38,500 15.50 12.50 CX35-48C EL296UH110XE60C 826798114ACX-041-230 TXV 38,500 15.50 12.50 CX35-48C EL296UH110XV60C 826799014ACX-041-230 TXV 39,000 16.00 13.00 CX35-48C SL280UH090V60C 826799514ACX-041-230 TXV 39,000 16.00 13.00 CX35-48C SL280UH090XV60C 826799414ACX-041-230 TXV 38,500 15.50 12.50 CX35-48C SL280UH110V60C 826799614ACX-041-230 TXV 38,500 15.50 12.50 CX35-48C SL280UH110XV60C 826799314ACX-041-230 TXV 38,500 15.50 12.50 CX35-48C SLP98UH090XV36C 826798414ACX-041-230 TXV 38,500 15.50 12.50 CX35-48C SLP98UH090XV48C 826798514ACX-041-230 TXV 38,500 15.50 12.50 CX35-48C SLP98UH090XV60C 826798614ACX-041-230 TXV 38,000 16.00 13.00 CX35-48C SLP98UH110XV60C 826798314ACX-041-230 TXV 38,500 14.50 12.20 CX35-49C 826799714ACX-041-230 TXV 39,000 16.00 13.00 CX35-49C EL180UH090E60C 826799914ACX-041-230 TXV 39,000 16.00 13.00 CX35-49C EL180UH110E60C 826800014ACX-041-230 TXV 39,000 16.00 13.00 CX35-49C EL180UH110XE60C 826800114ACX-041-230 TXV 38,500 16.00 13.00 CX35-49C EL195UH090XE48C 826800614ACX-041-230 TXV 39,000 15.50 12.50 CX35-49C EL195UH110XE60C 826800714ACX-041-230 TXV 38,500 16.00 13.00 CX35-49C EL296UH090XE48C 826800214ACX-041-230 TXV 39,000 15.50 12.50 CX35-49C EL296UH090XV48C 826799814ACX-041-230 TXV 39,000 15.50 12.50 CX35-49C EL296UH110XE60C 826800314ACX-041-230 TXV 39,500 16.00 13.00 CX35-49C EL296UH110XV60C 826800514ACX-041-230 TXV 39,000 16.00 13.00 CX35-49C SL280UH090V60C 826800814ACX-041-230 TXV 39,000 16.00 13.00 CX35-49C SL280UH110V60C 826800914ACX-041-230 TXV 38,500 16.00 13.00 CX35-49C SLP98UH110XV60C 8268004NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95F outdoor air temperature, 80F db / 67F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

    http://www.ahridirectory.org

  • 14ACX - 1.5 to 5 Ton Air Conditioner / Page 18

    AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

    Expansion Device Capacity SEER EER

    Coil or Air Handler Furnace

    AHRI Reference

    14ACX-041-230 TXV 38,000 15.50 12.50 CX35-50/60C EL180UH090E60C 826801014ACX-041-230 TXV 38,000 15.50 12.50 CX35-50/60C EL180UH110E60C 826801114ACX-041-230 TXV 38,000 15.50 12.50 CX35-50/60C EL180UH110XE60C 826801214ACX-041-230 TXV 38,000 15.50 12.50 CX35-50/60C EL195UH090XE48C 826801614ACX-041-230 TXV 38,500 15.50 12.50 CX35-50/60C EL195UH110XE60C 826801514ACX-041-230 TXV 38,000 15.50 12.50 CX35-50/60C EL296UH090XE48C 826801314ACX-041-230 TXV 38,500 15.50 12.50 CX35-50/60C EL296UH110XE60C 826801414ACX-041-230 TXV 40,000 16.00 13.00 CX35-60C EL180UH090E60C 826801714ACX-041-230 TXV 40,000 16.00 13.00 CX35-60C EL180UH110E60C 826801814ACX-041-230 TXV 40,000 16.00 13.00 CX35-60C EL180UH110XE60C 826801914ACX-041-230 TXV 39,500 16.00 13.00 CX35-60C EL195UH090XE48C 826803114ACX-041-230 TXV 40,000 16.00 13.00 CX35-60C EL195UH110XE60C 826803014ACX-041-230 TXV 39,500 16.00 13.00 CX35-60C EL296UH090XE48C 826802014ACX-041-230 TXV 39,500 16.00 13.00 CX35-60C EL296UH090XV36C 826802714ACX-041-230 TXV 40,000 16.00 13.00 CX35-60C EL296UH090XV48C 826802814ACX-041-230 TXV 40,000 16.00 13.00 CX35-60C EL296UH090XV60C 826802914ACX-041-230 TXV 40,000 16.00 13.00 CX35-60C EL296UH110XE60C 826802114ACX-041-230 TXV 40,000 16.00 13.00 CX35-60C EL296UH110XV60C 826802614ACX-041-230 TXV 40,000 16.00 13.00 CX35-60C SL280UH090V60C 826803214ACX-041-230 TXV 40,000 16.00 13.00 CX35-60C SL280UH110V60C 826803314ACX-041-230 TXV 39,500 16.00 13.00 CX35-60C SLP98UH090XV36C 826802214ACX-041-230 TXV 40,000 16.00 13.00 CX35-60C SLP98UH090XV48C 826802314ACX-041-230 TXV 40,000 16.00 13.00 CX35-60C SLP98UH090XV60C 826802414ACX-041-230 TXV 40,000 16.00 13.00 CX35-60C SLP98UH110XV60C 826802514ACX-047-230 TXV 46,000 15.00 12.50 C33-43 EL180UH090E48B 573512114ACX-047-230 TXV 46,000 15.00 12.50 C33-43 EL180UH090XE48B 573708414ACX-047-230 TXV 46,000 14.50 12.00 C33-43C 742664014ACX-047-230 TXV 45,000 14.70 12.20 C33-48 EL180UH090E48B 573512314ACX-047-230 TXV 45,000 15.00 12.50 C33-48 EL180UH090E60C 573603414ACX-047-230 TXV 45,000 14.70 12.20 C33-48 EL180UH090XE48B 573708714ACX-047-230 TXV 45,500 14.50 12.00 C33-48 EL180UH110E60C 573788614ACX-047-230 TXV 45,500 14.50 12.00 C33-48 EL180UH110XE60C 573894714ACX-047-230 TXV 45,000 14.70 12.20 C33-48 EL195UH090XE48C 469391914ACX-047-230 TXV 45,000 14.70 12.20 C33-48 EL195UH110XE60C 469393114ACX-047-230 TXV 45,000 14.70 12.20 C33-48 EL296UH090XE48C 564726414ACX-047-230 TXV 45,000 14.70 12.20 C33-48 EL296UH110XE60C 564722714ACX-047-230 TXV 45,000 14.70 12.20 C33-48 SL280UH090V60C 386917014ACX-047-230 TXV 45,000 14.70 12.20 C33-48 SL280UH090XV60C 423524114ACX-047-230 TXV 45,000 14.70 12.20 C33-48 SL280UH110V60C 386917114ACX-047-230 TXV 45,000 14.70 12.20 C33-48 SL280UH110XV60C 404013914ACX-047-230 TXV 46,500 14.50 12.00 C33-49 742664114ACX-047-230 TXV 47,000 15.70 13.00 C33-49 EL180UH090E60C 573603514ACX-047-230 TXV 46,500 15.70 13.00 C33-49 EL180UH110E60C 573785514ACX-047-230 TXV 46,500 15.70 13.00 C33-49 EL180UH110XE60C 573893214ACX-047-230 TXV 47,000 15.20 12.70 C33-49 EL195UH090XE48C 469392014ACX-047-230 TXV 47,000 15.50 12.70 C33-49 EL195UH110XE60C 469393214ACX-047-230 TXV 47,000 15.20 12.70 C33-49 EL296UH090XE48C 564726514ACX-047-230 TXV 47,000 15.20 12.70 C33-49 EL296UH090XV48C 505727814ACX-047-230 TXV 47,000 15.50 12.70 C33-49 EL296UH090XV60C 5057279NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95F outdoor air temperature, 80F db / 67F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

    http://www.ahridirectory.org

  • 14ACX - 1.5 to 5 Ton Air Conditioner / Page 19

    AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

    Expansion Device Capacity SEER EER

    Coil or Air Handler Furnace

    AHRI Reference

    14ACX-047-230 TXV 47,000 15.50 12.70 C33-49 EL296UH110XE60C 564722814ACX-047-230 TXV 47,000 15.50 12.70 C33-49 EL296UH110XV60C 505728014ACX-047-230 TXV 47,000 15.70 13.00 C33-49 SL280UH090V60C 425382314ACX-047-230 TXV 47,000 15.70 13.00 C33-49 SL280UH110V60C 425382414ACX-047-230 TXV 47,000 15.20 12.70 C33-49 SLP98UH090XV48C 514051214ACX-047-230 TXV 47,000 15.50 12.70 C33-49 SLP98UH090XV60C 514051314ACX-047-230 TXV 47,000 15.50 12.70 C33-49 SLP98UH110XV60C 514051414ACX-047-230 TXV 45,500 14.25 12.00 C33-50/60C 742664214ACX-047-230 TXV 45,500 15.20 12.50 C33-50/60C EL180UH090E60C 573603814ACX-047-230 TXV 46,000 14.70 12.20 C33-50/60C EL180UH110E60C 573785714ACX-047-230 TXV 46,000 14.70 12.20 C33-50/60C EL180UH110XE60C 573893514ACX-047-230 TXV 45,500 15.00 12.50 C33-50/60C EL195UH090XE48C 469392114ACX-047-230 TXV 45,500 15.00 12.50 C33-50/60C EL195UH110XE60C 469393314ACX-047-230 TXV 45,500 15.00 12.50 C33-50/60C EL296UH090XE48C 564726614ACX-047-230 TXV 45,500 15.00 12.50 C33-50/60C EL296UH110XE60C 564722914ACX-047-230 TXV 46,500 14.50 12.00 C33-60D 742664314ACX-047-230 TXV 47,000 15.70 13.00 C33-60D EL180UH135E60D 574607414ACX-047-230 TXV 47,000 15.20 12.70 C33-60D EL195UH135XE60D 469394314ACX-047-230 TXV 47,000 15.20 12.70 C33-60D EL296UH135XE60D 564727914ACX-047-230 TXV 47,000 14.50 12.50 C33-62C 386917314ACX-047-230 TXV 47,500 16.00 13.20 C33-62C EL180UH090E60C 573604014ACX-047-230 TXV 47,500 16.00 13.20 C33-62C EL180UH110E60C 573786014ACX-047-230 TXV 47,500 16.00 13.20 C33-62C EL180UH110XE60C 573893614ACX-047-230 TXV 47,500 15.70 13.00 C33-62C EL195UH090XE48C 469392214ACX-047-230 TXV 47,500 15.70 13.00 C33-62C EL195UH110XE60C 469393414ACX-047-230 TXV 47,500 15.70 13.00 C33-62C EL296UH090XE48C 564726714ACX-047-230 TXV 47,500 15.70 13.00 C33-62C EL296UH110XE60C 564723014ACX-047-230 TXV 48,000 16.00 13.00 C33-62C SL280UH090V60C 425382814ACX-047-230 TXV 47,500 16.00 13.00 C33-62C SL280UH110V60C 425382914ACX-047-230 TXV 47,000 14.50 12.00 C33-62D 742664414ACX-047-230 TXV 47,500 15.70 13.20 C33-62D EL180UH135E60D 574607514ACX-047-230 TXV 47,000 15.50 12.70 C33-62D EL195UH135XE60D 469394414ACX-047-230 TXV 47,000 15.50 12.70 C33-62D EL296UH135XE60D 564728014ACX-047-230 TXV 46,000 15.00 12.50 C35-48B EL180UH090E48B 826739414ACX-047-230 TXV 46,000 15.00 12.50 C35-48B EL180UH090XE48B 826739314ACX-047-230 TXV 46,000 15.00 12.50 C35-49C EL180UH090E60C 826739514ACX-047-230 TXV 46,500 15.10 12.50 C35-49C EL180UH110E60C 826739614ACX-047-230 TXV 46,500 15.10 12.50 C35-49C EL180UH110XE60C 826739714ACX-047-230 TXV 46,500 15.10 12.50 C35-49C EL195UH090XE48C 826740714ACX-047-230 TXV 46,500 15.50 12.50 C35-49C EL195UH110XE60C 826740614ACX-047-230 TXV 46,500 15.10 12.50 C35-49C EL296UH090XE48C 826739914ACX-047-230 TXV 47,000 15.10 12.50 C35-49C EL296UH090XV48C 826740314ACX-047-230 TXV 47,000 15.10 12.50 C35-49C EL296UH090XV60C 826740414ACX-047-230 TXV 46,500 15.50 12.50 C35-49C EL296UH110XE60C 826739814ACX-047-230 TXV 47,000 15.10 12.50 C35-49C EL296UH110XV60C 826740514ACX-047-230 TXV 47,000 15.50 12.50 C35-49C SL280UH090V60C 826740814ACX-047-230 TXV 47,000 15.10 12.50 C35-49C SL280UH110V60C 826740914ACX-047-230 TXV 47,000 15.10 12.50 C35-49C SLP98UH090XV48C 826740114ACX-047-230 TXV 47,000 15.50 12.50 C35-49C SLP98UH090XV60C 8267402NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95F outdoor air temperature, 80F db / 67F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

    http://www.ahridirectory.org

  • 14ACX - 1.5 to 5 Ton Air Conditioner / Page 20

    AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

    Expansion Device Capacity SEER EER

    Coil or Air Handler Furnace

    AHRI Reference

    14ACX-047-230 TXV 47,000 15.10 12.50 C35-49C SLP98UH110XV60C 826740014ACX-047-230 TXV 45,500 15.10 12.50 C35-50/60C EL180UH090E60C 826741014ACX-047-230 TXV 46,000 14.50 12.20 C35-50/60C EL180UH110E60C 826741114ACX-047-230 TXV 46,000 14.70 12.20 C35-50/60C EL180UH110XE60C 826741214ACX-047-230 TXV 45,500 15.00 12.20 C35-50/60C EL195UH090XE48C 826741614ACX-047-230 TXV 45,500 15.00 12.50 C35-50/60C EL195UH110XE60C 826741514ACX-047-230 TXV 45,500 15.00 12.20 C35-50/60C EL296UH090XE48C 826741414ACX-047-230 TXV 45,500 15.00 12.50 C35-50/60C EL296UH110XE60C 826741314ACX-047-230 TXV 47,000 14.50 12.20 C35-60C 826741714ACX-047-230 TXV 47,500 16.00 13.00 C35-60C EL180UH090E60C 826742014ACX-047-230 TXV 47,500 16.00 13.00 C35-60C EL180UH110E60C 826742114ACX-047-230 TXV 47,500 16.00 13.00 C35-60C EL180UH110XE60C 826742214ACX-047-230 TXV 47,500 15.50 12.50 C35-60C EL195UH090XE48C 826742614ACX-047-230 TXV 47,500 15.50 12.50 C35-60C EL195UH110XE60C 826742514ACX-047-230 TXV 47,500 15.50 12.50 C35-60C EL296UH090XE48C 826742414ACX-047-230 TXV 47,500 15.50 12.50 C35-60C EL296UH110XE60C 826742314ACX-047-230 TXV 48,000 16.00 13.00 C35-60C SL280UH090V60C 826742714ACX-047-230 TXV 48,000 16.00 13.00 C35-60C SL280UH090XV60C 826741814ACX-047-230 TXV 47,500 16.00 13.00 C35-60C SL280UH110V60C 826742814ACX-047-230 TXV 47,500 16.00 13.00 C35-60C SL280UH110XV60C 826741914ACX-047-230 TXV 47,500 15.50 12.50 C35-60D EL180UH135E60D 826742914ACX-047-230 TXV 47,000 15.50 12.50 C35-60D EL195UH135XE60D 826743114ACX-047-230 TXV 47,000 15.50 12.50 C35-60D EL296UH135XE60D 826743014ACX-047-230 TXV 46,500 15.00 12.50 CBX25UH-048 573279014ACX-047-230 TXV 47,000 16.00 13.00 CBX25UHV-048 697013214ACX-047-230 TXV 46,500 16.00 13.00 CBX27UH-048 386917414ACX-047-230 TXV 46,000 16.00 13.00 CBX32MV-060 386917514ACX-047-230 TXV 46,000 16.00 13.00 CBX40UHV-060 386917614ACX-047-230 TXV 47,500 15.50 12.70 CH33-43 EL180UH090E48B 573511314ACX-047-230 TXV 46,000 15.20 12.70 CH33-43 EL180UH090E60C 573601714ACX-047-230 TXV 47,500 15.50 12.70 CH33-43 EL180UH090XE48B 573707714ACX-047-230 TXV 46,500 15.00 12.50 CH33-43 EL180UH110E60C 573784114ACX-047-230 TXV 46,500 15.00 12.50 CH33-43 EL180UH110XE60C 573891814ACX-047-230 TXV 47,000 15.20 12.70 CH33-43 SL280UH090V48B 401667814ACX-047-230 TXV 46,500 15.20 12.70 CH33-43 SL280UH090V60C 425383014ACX-047-230 TXV 47,000 15.20 12.70 CH33-43 SL280UH090XV48B 403853514ACX-047-230 TXV 46,000 15.20 12.50 CH33-43 SL280UH110V60C 425383114ACX-047-230 TXV 46,000 14.25 12.00 CH33-43C 742664514ACX-047-230 TXV 46,000 15.00 12.50 CH33-43C EL195UH090XE48C 469392314ACX-047-230 TXV 46,000 15.20 12.70 CH33-43C EL195UH110XE60C 469393514ACX-047-230 TXV 46,000 15.00 12.50 CH33-43C EL296UH090XE48C 564726814ACX-047-230 TXV 46,000 15.20 12.70 CH33-43C EL296UH110XE60C 564723114ACX-047-230 TXV 45,500 14.70 12.20 CH33-44/48 EL180UH090E48B 573511514ACX-047-230 TXV 45,500 14.70 12.20 CH33-44/48 EL180UH090XE48B 573707914ACX-047-230 TXV 45,000 14.50 12.00 CH33-44/48 SL280UH090V48B 401667914ACX-047-230 TXV 45,000 14.50 12.00 CH33-44/48 SL280UH090XV48B 403853614ACX-047-230 TXV 45,500 15.20 12.50 CH33-48 EL180UH090E60C 573602014ACX-047-230 TXV 46,500 14.70 12.20 CH33-48 EL180UH110E60C 573784314ACX-047-230 TXV 46,500 14.70 12.20 CH33-48 EL180UH110XE60C 5738921NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95F outdoor air temperature, 80F db / 67F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

    http://www.ahridirectory.org

  • 14ACX - 1.5 to 5 Ton Air Conditioner / Page 21

    AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

    Expansion Device Capacity SEER EER

    Coil or Air Handler Furnace

    AHRI Reference

    14ACX-047-230 TXV 46,000 14.70 12.50 CH33-48 EL296UH090XV48C 505727514ACX-047-230 TXV 46,000 14.70 12.20 CH33-48 EL296UH090XV60C 505727614ACX-047-230 TXV 46,000 14.70 12.50 CH33-48 EL296UH110XV60C 505727714ACX-047-230 TXV 46,000 15.20 12.50 CH33-48 SL280UH090V60C 386918014ACX-047-230 TXV 46,000 15.20 12.50 CH33-48 SL280UH090XV60C 423524214ACX-047-230 TXV 46,000 15.00 12.50 CH33-48 SL280UH110V60C 386918114ACX-047-230 TXV 46,000 15.00 12.50 CH33-48 SL280UH110XV60C 404014314ACX-047-230 TXV 46,000 14.70 12.50 CH33-48 SLP98UH090XV48C 514046514ACX-047-230 TXV 46,000 14.70 12.20 CH33-48 SLP98UH090XV60C 514046614ACX-047-230 TXV 46,000 14.70 12.50 CH33-48 SLP98UH110XV60C 514046714ACX-047-230 TXV 45,500 14.25 12.00 CH33-48C 742664614ACX-047-230 TXV 45,500 14.70 12.50 CH33-48C EL195UH090XE48C 469392414ACX-047-230 TXV 45,500 14.70 12.50 CH33-48C EL195UH110XE60C 469393614ACX-047-230 TXV 45,500 14.70 12.50 CH33-48C EL296UH090XE48C 564726914ACX-047-230 TXV 45,500 14.70 12.50 CH33-48C EL296UH110XE60C 564723214ACX-047-230 TXV 46,500 14.50 12.00 CH33-49 742665214ACX-047-230 TXV 46,500 15.50 12.70 CH33-49 EL180UH090E60C 573602214ACX-047-230 TXV 47,500 15.20 12.70 CH33-49 EL180UH110E60C 573784514ACX-047-230 TXV 47,500 15.20 12.70 CH33-49 EL180UH110XE60C 573892214ACX-047-230 TXV 46,500 15.20 12.70 CH33-49 EL195UH090XE48C 469392514ACX-047-230 TXV 46,500 15.20 12.70 CH33-49 EL195UH110XE60C 469393714ACX-047-230 TXV 46,500 15.20 12.70 CH33-49 EL296UH090XE48C 564727014ACX-047-230 TXV 47,000 15.20 12.70 CH33-49 EL296UH090XV48C 505728414ACX-047-230 TXV 47,000 15.20 12.70 CH33-49 EL296UH090XV60C 505728514ACX-047-230 TXV 46,500 15.20 12.70 CH33-49 EL296UH110XE60C 564723314ACX-047-230 TXV 47,000 15.20 12.70 CH33-49 EL296UH110XV60C 505728614ACX-047-230 TXV 47,000 15.20 12.70 CH33-49 SLP98UH090XV48C 514053714ACX-047-230 TXV 47,000 15.20 12.70 CH33-49 SLP98UH090XV60C 514053814ACX-047-230 TXV 47,000 15.20 12.70 CH33-49 SLP98UH110XV60C 514053914ACX-047-230 TXV 46,500 14.50 12.20 CH33-50/60C 425383514ACX-047-230 TXV 46,500 15.50 12.70 CH33-50/60C EL180UH090E60C 573602414ACX-047-230 TXV 47,000 15.00 12.50 CH33-50/60C EL180UH110E60C 573784714ACX-047-230 TXV 47,000 15.00 12.50 CH33-50/60C EL180UH110XE60C 573892514ACX-047-230 TXV 46,500 15.20 12.70 CH33-50/60C EL195UH090XE48C 469392614ACX-047-230 TXV 46,500 15.20 12.70 CH33-50/60C EL195UH110XE60C 469393814ACX-047-230 TXV 46,500 15.20 12.70 CH33-50/60C EL296UH090XE48C 564727114ACX-047-230 TXV 46,500 15.20 12.70 CH33-50/60C EL296UH110XE60C 564723414ACX-047-230 TXV 46,000 14.25 12.00 CH33-60D 742664714ACX-047-230 TXV 46,500 15.50 12.70 CH33-60D EL180UH135E60D 574607014ACX-047-230 TXV 46,500 15.00 12.50 CH33-60D EL195UH135XE60D 469394514ACX-047-230 TXV 46,500 15.00 12.50 CH33-60D EL296UH135XE60D 564728114ACX-047-230 TXV 46,500 14.50 12.00 CH33-62D 742664814ACX-047-230 TXV 47,000 15.70 13.00 CH33-62D EL180UH135E60D 574607114ACX-047-230 TXV 47,000 15.20 12.70 CH33-62D EL195UH135XE60D 469394614ACX-047-230 TXV 47,000 15.20 12.70 CH33-62D EL296UH135XE60D 564728214ACX-047-230 TXV 47,000 14.50 12.00 CH35-42B 716395714ACX-047-230 TXV 47,500 15.50 12.50 CH35-42B EL180UH090E48B 716395214ACX-047-230 TXV 47,500 15.00 12.50 CH35-42B SL280UH090XV48B 716395514ACX-047-230 TXV 46,000 14.50 12.00 CH35-42C 7163959NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95F outdoor air temperature, 80F db / 67F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

    http://www.ahridirectory.org

  • 14ACX - 1.5 to 5 Ton Air Conditioner / Page 22

    AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

    Expansion Device Capacity SEER EER

    Coil or Air Handler Furnace

    AHRI Reference

    14ACX-047-230 TXV 46,000 15.10 12.50 CH35-42C EL180UH090E60C 716397014ACX-047-230 TXV 47,000 15.00 12.50 CH35-42C EL180UH110E60C 716397214ACX-047-230 TXV 46,000 15.10 12.50 CH35-42C EL195UH090XE48C 716396114ACX-047-230 TXV 46,000 15.10 12.50 CH35-42C EL195UH110XE60C 716396314ACX-047-230 TXV 46,000 15.10 12.50 CH35-42C EL296UH090XE48C 716396514ACX-047-230 TXV 46,000 15.10 12.50 CH35-42C EL296UH110XE60C 716396814ACX-047-230 TXV 46,500 15.10 12.50 CH35-42C SL280UH090V60C 716397414ACX-047-230 TXV 46,500 15.10 12.50 CH35-42C SL280UH110V60C 716397614ACX-047-230 TXV 46,500 15.00 12.50 CH35-42C SLP98UH090XV48C 716397814ACX-047-230 TXV 46,500 15.00 12.50 CH35-42C SLP98UH090XV60C 716398114ACX-047-230 TXV 46,500 15.00 12.50 CH35-42C SLP98UH110XV60C 716398214ACX-047-230 TXV 46,000 14.50 12.00 CH35-48B 716399114ACX-047-230 TXV 46,000 15.00 12.50 CH35-48B EL180UH090E48B 716398514ACX-047-230 TXV 46,000 14.50 12.00 CH35-48B SL280UH090V48B 716398814ACX-047-230 TXV 46,000 14.50 12.00 CH35-48C 716399314ACX-047-230 TXV 46,000 15.10 12.50 CH35-48C EL180UH090E60C 716401414ACX-047-230 TXV 46,500 15.00 12.50 CH35-48C EL180UH110E60C 716401614ACX-047-230 TXV 46,000 15.00 12.50 CH35-48C EL195UH090XE48C 716399514ACX-047-230 TXV 46,000 15.10 12.50 CH35-48C EL195UH110XE60C 716399814ACX-047-230 TXV 46,000 15.00 12.50 CH35-48C EL296UH090XE48C 716400114ACX-047-230 TXV 46,000 15.00 12.50 CH35-48C EL296UH090XV48C 716400314ACX-047-230 TXV 46,000 15.00 12.00 CH35-48C EL296UH090XV60C 716400614ACX-047-230 TXV 46,000 15.10 12.50 CH35-48C EL296UH110XE60C 716400914ACX-047-230 TXV 46,000 15.00 12.50 CH35-48C EL296UH110XV60C 716401114ACX-047-230 TXV 46,500 15.10 12.50 CH35-48C SL280UH090V60C 716401914ACX-047-230 TXV 46,000 15.10 12.50 CH35-48C SL280UH110V60C 716402114ACX-047-230 TXV 46,000 15.00 12.50 CH35-48C SLP98UH090XV48C 716402514ACX-047-230 TXV 46,000 15.00 12.00 CH35-48C SLP98UH090XV60C 716402714ACX-047-230 TXV 46,000 15.00 12.50 CH35-48C SLP98UH110XV60C 716403014ACX-047-230 TXV 47,000 14.50 12.00 CH35-51C 716403314ACX-047-230 TXV 47,000 15.50 13.00 CH35-51C EL180UH090E60C 716405414ACX-047-230 TXV 47,500 15.10 12.50 CH35-51C EL180UH110E60C 716405614ACX-047-230 TXV 47,000 15.10 12.50 CH35-51C EL195UH090XE48C 716403514ACX-047-230 TXV 47,000 15.10 12.50 CH35-51C EL195UH110XE60C 716403814ACX-047-230 TXV 47,000 15.10 12.50 CH35-51C EL296UH090XE48C 716404214ACX-047-230 TXV 47,000 15.10 12.50 CH35-51C EL296UH090XV48C 716404414ACX-047-230 TXV 47,000 15.10 12.50 CH35-51C EL296UH090XV60C 716404714ACX-047-230 TXV 47,000 15.10 12.50 CH35-51C EL296UH110XE60C 716404914ACX-047-230 TXV 47,000 15.10 12.50 CH35-51C EL296UH110XV60C 716405214ACX-047-230 TXV 47,000 15.50 12.50 CH35-51C SL280UH090V60C 716405914ACX-047-230 TXV 47,000 15.10 12.50 CH35-51C SL280UH110V60C 716406214ACX-047-230 TXV 47,000 15.10 12.50 CH35-51C SLP98UH090XV48C 716406514ACX-047-230 TXV 47,000 15.10 12.50 CH35-51C SLP98UH090XV60C 716406714ACX-047-230 TXV 47,000 15.10 12.50 CH35-51C SLP98UH110XV60C 716407014ACX-047-230 TXV 47,000 14.50 12.00 CH35-60D 716407314ACX-047-230 TXV 47,500 15.50 13.00 CH35-60D EL180UH135E60D 716408014ACX-047-230 TXV 47,000 15.10 12.50 CH35-60D EL195UH135XE60D 716407514ACX-047-230 TXV 47,000 15.10 12.50 CH35-60D EL296UH135XE60D 716407814ACX-047-230 TXV 47,000 15.50 13.00 CH35-60D SL280UH135V60D 7164083NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95F outdoor air temperature, 80F db / 67F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

    http://www.ahridirectory.org

  • 14ACX - 1.5 to 5 Ton Air Conditioner / Page 23

    AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

    Expansion Device Capacity SEER EER

    Coil or Air Handler Furnace

    AHRI Reference

    14ACX-047-230 TXV 47,000 15.50 12.50 CH35-60D SLP98UH135V60D 716408614ACX-047-230 TXV 45,000 15.20 12.50 CR33-50/60 EL180DF110E60C 573350714ACX-047-230 TXV 44,500 14.70 12.20 CR33-50/60 EL195DF090XE48C 469391714ACX-047-230 TXV 44,500 15.20 12.20 CR33-50/60 EL195DF110XE60C 469391814ACX-047-230 TXV 44,500 14.70 12.20 CR33-50/60 EL296DF090XE48C 564726214ACX-047-230 TXV 44,500 15.20 12.20 CR33-50/60 EL296DF110XE60C 564726314ACX-047-230 TXV 45,500 15.70 13.00 CR33-50/60 SL280DF090V60C 386918614ACX-047-230 TXV 45,500 15.70 13.00 CR33-50/60 SL280DF110V60C 386918714ACX-047-230 TXV 46,000 15.00 12.50 CX34-43 EL180UH090E48B 573511614ACX-047-230 TXV 46,000 15.00 12.50 CX34-43 EL180UH090XE48B 573708114ACX-047-230 TXV 46,000 14.70 12.50 CX34-43 SL280UH090V48B 401667614ACX-047-230 TXV 46,000 14.70 12.50 CX34-43 SL280UH090XV48B 403853314ACX-047-230 TXV 46,000 14.25 12.00 CX34-43C 742664914ACX-047-230 TXV 45,000 14.70 12.20 CX34-44/48 EL180UH090E48B 573511814ACX-047-230 TXV 45,000 15.00 12.50 CX34-44/48 EL180UH090E60C 573602614ACX-047-230 TXV 45,000 14.70 12.20 CX34-44/48 EL180UH090XE48B 573708314ACX-047-230 TXV 45,500 14.50 12.00 CX34-44/48 EL180UH110E60C 573788414ACX-047-230 TXV 45,500 14.50 12.00 CX34-44/48 EL180UH110XE60C 573894414ACX-047-230 TXV 45,000 14.70 12.20 CX34-44/48 EL195UH090XE48C 469392714ACX-047-230 TXV 45,000 14.70 12.20 CX34-44/48 EL195UH110XE60C 469393914ACX-047-230 TXV 45,000 14.70 12.20 CX34-44/48 EL296UH090XE48C 564727214ACX-047-230 TXV 45,000 14.70 12.20 CX34-44/48 EL296UH090XV48C 505727214ACX-047-230 TXV 45,000 14.50 12.20 CX34-44/48 EL296UH090XV60C 505727314ACX-047-230 TXV 45,000 14.70 12.20 CX34-44/48 EL296UH110XE60C 564723514ACX-047-230 TXV 45,000 14.70 12.20 CX34-44/48 EL296UH110XV60C 505727414ACX-047-230 TXV 45,000 14.50 12.20 CX34-44/48 SL280UH090V48B 401667714ACX-047-230 TXV 45,000 14.70 12.20 CX34-44/48 SL280UH090V60C 386919414ACX-047-230 TXV 45,000 14.50 12.20 CX34-44/48 SL280UH090XV48B 403853414ACX-047-230 TXV 45,000 14.70 12.20 CX34-44/48 SL280UH090XV60C 423524314ACX-047-230 TXV 45,000 14.70 12.20 CX34-44/48 SL280UH110V60C 386919514ACX-047-230 TXV 45,000 14.70 12.20 CX34-44/48 SL280UH110XV60C 404014714ACX-047-230 TXV 45,000 14.70 12.20 CX34-44/48 SLP98UH090XV48C 514046214ACX-047-230 TXV 45,000 14.50 12.20 CX34-44/48 SLP98UH090XV60C 514046314ACX-047-230 TXV 45,000 14.70 12.20 CX34-44/48 SLP98UH110XV60C 514046414ACX-047-230 TXV 46,500 14.50 12.00 CX34-49 742665314ACX-047-230 TXV 47,000 15.70 13.00 CX34-49 EL180UH090E60C 573602814ACX-047-230 TXV 46,500 15.70 13.00 CX34-49 EL180UH110E60C 573785014ACX-047-230 TXV 46,500 15.70 13.00 CX34-49 EL180UH110XE60C 573892614ACX-047-230 TXV 47,000 15.20 12.70 CX34-49 EL195UH090XE48C 469392814ACX-047-230 TXV 47,000 15.50 12.70 CX34-49 EL195UH110XE60C 469394014ACX-047-230 TXV 47,000 15.20 12.70 CX34-49 EL296UH090XE48C 564727314ACX-047-230 TXV 47,000 15.20 12.70 CX34-49 EL296UH090XV48C 505728114ACX-047-230 TXV 47,000 15.50 12.70 CX34-49 EL296UH090XV60C 505728214ACX-047-230 TXV 47,000 15.50 12.70 CX34-49 EL296UH110XE60C 564727614ACX-047-230 TXV 47,000 15.50 12.70 CX34-49 EL296UH110XV60C 505728314ACX-047-230 TXV 47,000 15.70 13.00 CX34-49 SL280UH090V60C 425383614ACX-047-230 TXV 47,000 15.70 13.00 CX34-49 SL280UH110V60C 425383714ACX-047-230 TXV 47,000 15.20 12.70 CX34-49 SLP98UH090XV48C 514052414ACX-047-230 TXV 47,000 15.50 12.70 CX34-49 SLP98UH090XV60C 5140525NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95F outdoor air temperature, 80F db / 67F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

    http://www.ahridirectory.org

  • 14ACX - 1.5 to 5 Ton Air Conditioner / Page 24

    AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

    Expansion Device Capacity SEER EER

    Coil or Air Handler Furnace

    AHRI Reference

    14ACX-047-230 TXV 47,000 15.50 12.70 CX34-49 SLP98UH110XV60C 514052614ACX-047-230 TXV 45,500 14.25 12.00 CX34-50/60C 742665714ACX-047-230 TXV 45,500 15.20 12.50 CX34-50/60C EL180UH090E60C 573603014ACX-047-230 TXV 46,000 14.70 12.20 CX34-50/60C EL180UH110E60C 573785114ACX-047-230 TXV 46,000 14.70 12.20 CX34-50/60C EL180UH110XE60C 573892914ACX-047-230 TXV 45,500 15.00 12.50 CX34-50/60C EL195UH090XE48C 469392914ACX-047-230 TXV 45,500 15.00 12.50 CX34-50/60C EL195UH110XE60C 469394114ACX-047-230 TXV 45,500 15.00 12.50 CX34-50/60C EL296UH090XE48C 564727414ACX-047-230 TXV 45,500 15.00 12.50 CX34-50/60C EL296UH110XE60C 564727714ACX-047-230 TXV 46,500 14.50 12.00 CX34-60D 742665414ACX-047-230 TXV 47,000 15.70 13.00 CX34-60D EL180UH135E60D 574607214ACX-047-230 TXV 47,000 15.20 12.70 CX34-60D EL195UH135XE60D 469394714ACX-047-230 TXV 47,000 15.20 12.70 CX34-60D EL296UH135XE60D 564728314ACX-047-230 TXV 47,000 14.50 12.50 CX34-62C 386919714ACX-047-230 TXV 47,500 16.00 13.20 CX34-62C EL180UH090E60C 573603214ACX-047-230 TXV 47,500 16.00 13.20 CX34-62C EL180UH110E60C 573785414ACX-047-230 TXV 47,500 16.00 13.20 CX34-62C EL180UH110XE60C 573893114ACX-047-230 TXV 47,500 15.70 13.00 CX34-62C EL195UH090XE48C 469393014ACX-047-230 TXV 47,500 15.70 13.00 CX34-62C EL195UH110XE60C 469394214ACX-047-230 TXV 47,500 15.70 13.00 CX34-62C EL296UH090XE48C 564727514ACX-047-230 TXV 47,500 15.70 13.00 CX34-62C EL296UH110XE60C 564727814ACX-047-230 TXV 48,000 16.00 13.00 CX34-62C SL280UH090V60C 425384114ACX-047-230 TXV 47,500 16.00 13.00 CX34-62C SL280UH110V60C 425384214ACX-047-230 TXV 47,000 14.50 12.00 CX34-62D 742665514ACX-047-230 TXV 47,500 15.70 13.20 CX34-62D EL180UH135E60D 574607314ACX-047-230 TXV 47,000 15.50 12.70 CX34-62D EL195UH135XE60D 469394814ACX-047-230 TXV 47,000 15.50 12.70 CX34-62D EL296UH135XE60D 564728414ACX-047-230 TXV 46,000 15.00 12.50 CX35-48B EL180UH090E48B 826743314ACX-047-230 TXV 46,000 15.00 12.50 CX35-48B EL180UH090XE48B 826743214ACX-047-230 TXV 46,000 14.50 12.20 CX35-48B SL280UH090V48B 826743514ACX-047-230 TXV 46,000 14.50 12.20 CX35-48B SL280UH090XV48B 826743414ACX-047-230 TXV 46,500 15.10 12.50 CX35-49C EL180UH110E60C 826743614ACX-047-230 TXV 46,500 15.10 12.50 CX35-49C EL180UH110XE60C 826743714ACX-047-230 TXV 46,500 15.10 12.50 CX35-49C EL195UH090XE48C 826744714ACX-047-230 TXV 46,500 15.50 12.50 CX35-49C EL195UH110XE60C 826744614ACX-047-230 TXV 46,500 15.10 12.50 CX35-49C EL296UH090XE48C 826743814ACX-047-230 TXV 47,000 15.10 12.50 CX35-49C EL296UH090XV48C 826744314ACX-047-230 TXV 47,000 15.10 12.50 CX35-49C EL296UH090XV60C 826744414ACX-047-230 TXV 46,500 15.50 12.50 CX35-49C EL296UH110XE60C 826743914ACX-047-230 TXV 47,000 15.10 12.50 CX35-49C EL296UH110XV60C 826744514ACX-047-230 TXV 47,000 15.50 12.50 CX35-49C SL280UH090V60C 826744814ACX-047-230 TXV 47,000 15.10 12.50 CX35-49C SL280UH110V60C 826744914ACX-047-230 TXV 47,000 15.00 12.50 CX35-49C SLP98UH090XV48C 826744114ACX-047-230 TXV 47,000 15.10 12.50 CX35-49C SLP98UH090XV60C 826744214ACX-047-230 TXV 47,000 15.10 12.50 CX35-49C SLP98UH110XV60C 826744014ACX-047-230 TXV 45,500 15.10 12.50 CX35-50/60C EL180UH090E60C 826745014ACX-047-230 TXV 46,000 14.50 12.20 CX35-50/60C EL180UH110E60C 826745114ACX-047-230 TXV 46,000 14.70 12.20 CX35-50/60C EL180UH110XE60C 826745214ACX-047-230 TXV 45,500 15.00 12.20 CX35-50/60C EL195UH090XE48C 8267456NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95F outdoor air temperature, 80F db / 67F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

    http://www.ahridirectory.org

  • 14ACX - 1.5 to 5 Ton Air Conditioner / Page 25

    AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

    Expansion Device Capacity SEER EER

    Coil or Air Handler Furnace

    AHRI Reference

    14ACX-047-230 TXV 45,500 15.00 12.50 CX35-50/60C EL195UH110XE60C 826745514ACX-047-230 TXV 45,500 15.00 12.50 CX35-50/60C EL296UH090XE48C 826745314ACX-047-230 TXV 45,500 15.00 12.20 CX35-50/60C EL296UH110XE60C 826745414ACX-047-230 TXV 47,000 14.50 12.20 CX35-60C 826745714ACX-047-230 TXV 47,500 16.00 13.00 CX35-60C EL180UH090E60C 826746014ACX-047-230 TXV 47,500 16.00 13.00 CX35-60C EL180UH110E60C 826746114ACX-047-230 TXV 47,500 16.00 13.00 CX35-60C EL180UH110XE60C 826746214ACX-047-230 TXV 47,500 15.50 12.50 CX35-60C EL195UH090XE48C 826746614ACX-047-230 TXV 47,500 15.50 12.50 CX35-60C EL195UH110XE60C 826746514ACX-047-230 TXV 47,500 15.50 12.50 CX35-60C EL296UH090XE48C 826746314ACX-047-230 TXV 47,500 15.50 12.50 CX35-60C EL296UH110XE60C 826746414ACX-047-230 TXV 48,000 16.00 13.00 CX35-60C SL280UH090V60C 826746714ACX-047-230 TXV 48,000 16.00 13.00 CX35-60C SL280UH090XV60C 826745814ACX-047-230 TXV 47,500 16.00 13.00 CX35-60C SL280UH110V60C 826746814ACX-047-230 TXV 47,500 16.00 13.00 CX35-60C SL280UH110XV60C 826745914ACX-047-230 TXV 47,500 15.50 12.50 CX35-60D EL180UH135E60D 826746914ACX-047-230 TXV 47,000 15.50 12.50 CX35-60D EL195UH135XE60D 826747114ACX-047-230 TXV 47,000 15.50 12.50 CX35-60D EL296UH135XE60D 826747014ACX-048-230 TXV 48,000 14.25 12.00 C33-43B EL180UH090E48B 748634014ACX-048-230 TXV 48,000 14.25 12.00 C33-43B EL180UH090XE48B 748634114ACX-048-230 TXV 48,000 14.50 12.00 C33-43C EL180UH090E60C 748635014ACX-048-230 TXV 47,500 14.50 12.00 C33-43C EL180UH110E60C 748635114ACX-048-230 TXV 47,500 14.50 12.00 C33-43C EL180UH110XE60C 748635214ACX-048-230 TXV 48,000 14.50 12.00 C33-43C EL195UH090XE48C 748634214ACX-048-230 TXV 48,000 14.50 12.00 C33-43C EL195UH110XE60C 748634414ACX-048-230 TXV 48,000 14.50 12.00 C33-43C EL296UH090XE48C 748634314ACX-048-230 TXV 48,000 14.25 12.00 C33-43C EL296UH090XV48C 748634614ACX-048-230 TXV 48,000 14.25 12.00 C33-43C EL296UH090XV60C 748634714ACX-048-230 TXV 48,000 14.50 12.00 C33-43C EL296UH110XE60C 748634514ACX-048-230 TXV 48,000 14.50 12.00 C33-43C EL296UH110XV48C 748634814ACX-048-230 TXV 48,000 14.25 12.00 C33-43C EL296UH110XV60C 748634914ACX-048-230 TXV 48,000 14.50 12.00 C33-43C SL280UH090V60C 748635414ACX-048-230 TXV 48,000 14.50 12.00 C33-43C SL280UH090XV60C 748635314ACX-048-230 TXV 48,000 14.50 12.00 C33-43C SL280UH110V60C 748635514ACX-048-230 TXV 48,000 14.50 12.00 C33-43C SL280UH110XV60C 748635614ACX-048-230 TXV 48,000 14.25 12.00 C33-43C SLP98UH090XV48C 748635714ACX-048-230 TXV 48,000 14.25 12.00 C33-43C SLP98UH090XV60C 748635814ACX-048-230 TXV 48,000 14.25 12.00 C33-43C SLP98UH110XV60C 748635914ACX-048-230 TXV 47,000 14.00 11.70 C33-48B EL180UH090E48B 748636014ACX-048-230 TXV 47,000 14.00 11.70 C33-48B EL180UH090XE48B 748636114ACX-048-230 TXV 46,500 14.25 11.70 C33-48C EL180UH090E60C 748636814ACX-048-230 TXV 47,500 14.00 11.70 C33-48C EL180UH110E60C 748636914ACX-048-230 TXV 47,500 14.00 11.70 C33-48C EL180UH110XE60C 748637014ACX-048-230 TXV 46,500 14.00 11.70 C33-48C EL195UH090XE48C 748636214ACX-048-230 TXV 46,500 14.00 11.70 C33-48C EL195UH110XE60C 748636414ACX-048-230 TXV 46,500 14.00 11.70 C33-48C EL296UH090XE48C 748636314ACX-048-230 TXV 47,000 14.00 11.70 C33-48C EL296UH090XV48C 748636614ACX-048-230 TXV 46,500 14.00 11.70 C33-48C EL296UH110XE60C 748636514ACX-048-230 TXV 47,000 14.00 11.70 C33-48C EL296UH110XV48C 7486367NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95F outdoor air temperature, 80F db / 67F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

    http://www.ahridirectory.org

  • 14ACX - 1.5 to 5 Ton Air Conditioner / Page 26

    AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

    Expansion Device Capacity SEER EER

    Coil or Air Handler Furnace

    AHRI Reference

    14ACX-048-230 TXV 47,000 14.25 11.70 C33-48C SL280UH090V60C 748637114ACX-048-230 TXV 47,000 14.25 11.70 C33-48C SL280UH090XV60C 748637214ACX-048-230 TXV 47,000 14.00 11.70 C33-48C SL280UH110V60C 748637314ACX-048-230 TXV 47,000 14.00 11.70 C33-48C