©Tdh / Fabrice Pédrono - Afghanistan Tdh Syrian crisis response in Jordan & Lebanon.
143.3' of TDH · 6/1/2016 · 143.3' of TDH 10.3 gpm Field flow and pump calculations for drip...
Transcript of 143.3' of TDH · 6/1/2016 · 143.3' of TDH 10.3 gpm Field flow and pump calculations for drip...
SCALE AS NOTED
BY SRH
PAGE
7 OF 10
S.R.
HAR
TSEL
L, R
.E.H
.S.
P.O
. BO
X 34
2PA
CIFI
CA, C
A 94
044
srha
rtse
ll@gm
ail.c
om (
650)
888
-241
9
CORD
OBA
CEN
TER
1404
5 M
ON
TERE
Y RO
ADSA
N M
ARTI
N, C
A 95
046
APN
779
-06-
002
NO
N-R
ESID
ENTI
ALSE
PTIC
SYS
TEM
CALC
ULA
TIO
NS
SEPTIC 720.3
gpm
MINIMAL SYSTEMHEAD & GPM
PUMP SELECTED
PERFORMANCE CURVEOF SELECTED PUMP
SPECIFICATIONS OFPUMP SELECTED
ORENCO PF SERIES PF100712 240 VOLTS/1 HORSEPOWER/1 PHASE
20 15 1 2 50
PUMP SYSTEM WORKSHEETDesigner (REHS or RCE) ____srhartsell, rehs 5979_________________________________Number of bedrooms_____0______ Total square footage of living space_______na_____Septic tank size____20000 gallons_____ Installed drainfield ______________ Expansion drainfield_____na_______Elevation of treatment inlet _________Elevation of pump off (ft) - ___________Total lift (Ft Head) = ____10 (A)TIGHT LINEDiameter of tight line (inches) _ 2__Length of tight line from pump to upper drainfield (ft) __ _20______ (B)FITTINGSNo. of Fittings Pipe LengthEquivalent (ft) See chart Total PipeEquivalent (ft)___90o standard elbow X _______ =__________45o standard elbow X _______ =__________90o long radius elbow X _______ =__________other fittings X _______ =__________gate valve (fully open) X _______ =__________check valve x _______ =_______(conventional swing)TOTAL=_______ (C)Total Length of Pipe = B + C = ________ (D)CALCULATIONS:Friction Loss in Pipes and Fittings:(D/100 ft) x _______ (friction loss per chart) = _______ (E) Head in FeetRequired Pump Size:_____ (A) + _____ (E) = ______ (F) Total Pumping Head in FeetPump Size:(F) versus GPM = Pump Size (refer to pump curve)Pump Model: (Attach Pump Curve)_____GPM at ______ (G) (ft of head: from pump curve) Manufacturer/Model______________________
288298
pump specification for flow equalization tank
pump for equalization tank SPECIFICATIONS OFPUMP SELECTED FOREQUALIZATION CHAMBER
SPECIFICATIONS OFPUMP SELECTED
.5
6 612 2.5 5
150 50d valve
6181
30
5.53because valve is 1.5"
4.47
10 14.474.47
15' Goulds WE series 0511
November 30, 2015
REVISIONS1 4-15-2016COUNTY COMMENTS SRH
143.3' of TDH
10.3
gpm
Field flow and pump calculations for drip system - design spreadsheets from Geoflow
pump performance curve for drip system from Orenco systems, inc
pump specifications from Orenco systems, inc
equalization tank pump specifications from Goulds
equalization tank pump specifications from Goulds
equalization tank pump specifications from Goulds
equalization tank pump specifications from Goulds
from Orenco Systems, incfrom Orenco Systems, inc
from Orenco Systems, inc
from Orenco Systems, inc