1401 Valley View Lane
Irving, TX 75061
41-15208 Test Tool for Externally Controlled Compressors
JANUARY 2010
www.omega-usa.com
![Page 2: 1401 Valley View Lane Irving, TX 75061 41-15208 Test Tool for Externally Controlled Compressors JANUARY 2010 .](https://reader035.fdocuments.net/reader035/viewer/2022070415/56649ec85503460f94bd459f/html5/thumbnails/2.jpg)
Denso and Sanden compressors can be tested with the CLTDenso:
7SEU16
6SEU14
5SE09C
Sanden:
PXE 13
PXE 16
These models can be found in BMW, Mercedes, Toyota
and VAG cars
7SEU17
6SEU16
5SER09
![Page 3: 1401 Valley View Lane Irving, TX 75061 41-15208 Test Tool for Externally Controlled Compressors JANUARY 2010 .](https://reader035.fdocuments.net/reader035/viewer/2022070415/56649ec85503460f94bd459f/html5/thumbnails/3.jpg)
The valve is regulated by the board electronic….
…these signals are hard to measure
Piston
EMPCV
Swash plate
Reduce spring
Main shaft Rotor Pin Shoe
Mechanical torque limiter
Cam Orifice
No Clutch
![Page 4: 1401 Valley View Lane Irving, TX 75061 41-15208 Test Tool for Externally Controlled Compressors JANUARY 2010 .](https://reader035.fdocuments.net/reader035/viewer/2022070415/56649ec85503460f94bd459f/html5/thumbnails/4.jpg)
CLT1 supports two areas
Identifying the root cause
Right Diagnosis
Systematical search
Minimizing the costs
Service levelQuicker service
Better cost coverage
![Page 5: 1401 Valley View Lane Irving, TX 75061 41-15208 Test Tool for Externally Controlled Compressors JANUARY 2010 .](https://reader035.fdocuments.net/reader035/viewer/2022070415/56649ec85503460f94bd459f/html5/thumbnails/5.jpg)
The tester improves the diagnosis and thereby save money
It eliminates the wrong diagnosisYou do not need to guess
It saves time
The variable area of the compressor can be tested.
It saves money
![Page 6: 1401 Valley View Lane Irving, TX 75061 41-15208 Test Tool for Externally Controlled Compressors JANUARY 2010 .](https://reader035.fdocuments.net/reader035/viewer/2022070415/56649ec85503460f94bd459f/html5/thumbnails/6.jpg)
You can run the compressorwithout removing it!
Just jack out the compressor connector
Connect simulator on the free cable
Connect CLT to the compressor
Connect Power supply to the vehicle battery
The compressor is now ready to be run and pressure to be tested
![Page 7: 1401 Valley View Lane Irving, TX 75061 41-15208 Test Tool for Externally Controlled Compressors JANUARY 2010 .](https://reader035.fdocuments.net/reader035/viewer/2022070415/56649ec85503460f94bd459f/html5/thumbnails/7.jpg)
The simulator prevent the board electronic to generate and save fault messages
Clearing the fault memory is a time consuming activity avoided by connecting the simulator
![Page 8: 1401 Valley View Lane Irving, TX 75061 41-15208 Test Tool for Externally Controlled Compressors JANUARY 2010 .](https://reader035.fdocuments.net/reader035/viewer/2022070415/56649ec85503460f94bd459f/html5/thumbnails/8.jpg)
The CLT 1 is easy to connect
Compressor cable Power supply cable2-polig 3-polig
![Page 9: 1401 Valley View Lane Irving, TX 75061 41-15208 Test Tool for Externally Controlled Compressors JANUARY 2010 .](https://reader035.fdocuments.net/reader035/viewer/2022070415/56649ec85503460f94bd459f/html5/thumbnails/9.jpg)
Open circuit and over load are directly indicated
OC = ”Open Circuit” = ”Poor contact. Carefully knock 2-3 times on the valve
The diode still indicates – change compressor
OL = ”Over Load” =
Short cut
Change compressor directly
![Page 10: 1401 Valley View Lane Irving, TX 75061 41-15208 Test Tool for Externally Controlled Compressors JANUARY 2010 .](https://reader035.fdocuments.net/reader035/viewer/2022070415/56649ec85503460f94bd459f/html5/thumbnails/10.jpg)
Control the compressor effect with the CLT
Change the effect with the + / - buttons.
You can directly see if the compressor react or not!
Time consumption: 5 min to connect everything.
Max 10 to test!
Result within 15 minutes!!!
![Page 11: 1401 Valley View Lane Irving, TX 75061 41-15208 Test Tool for Externally Controlled Compressors JANUARY 2010 .](https://reader035.fdocuments.net/reader035/viewer/2022070415/56649ec85503460f94bd459f/html5/thumbnails/11.jpg)
CLT1 – Delivery content