SOLAR REFRIGERATION
Submitted by: Presented by:
AMIT PRAJAPATI
![Page 2: 134167289 Solar Refrigeration Ppt](https://reader035.fdocuments.net/reader035/viewer/2022081414/55cf9a96550346d033a276b3/html5/thumbnails/2.jpg)
ABOUT REFRIGERATIONTYPES OF REFRIGERATION
ABOUT SOLAR REFRIGERATION
WORKING CYCLES
- V.C.R CYCLE
- V.A.R CYCLE
- SOLID ABSORPTION CYCLE
ADVANTAGES
APPLICATIONS
![Page 3: 134167289 Solar Refrigeration Ppt](https://reader035.fdocuments.net/reader035/viewer/2022081414/55cf9a96550346d033a276b3/html5/thumbnails/3.jpg)
Refrigeration is the removal of heat from a space at a temperature lower than the surrounding temperature.
In other word Refrigeration is the science of providing and maintaining temperature below that of surrounding atmosphere.
![Page 4: 134167289 Solar Refrigeration Ppt](https://reader035.fdocuments.net/reader035/viewer/2022081414/55cf9a96550346d033a276b3/html5/thumbnails/4.jpg)
There are many types of refrigeration like….1. Ice Refrigeration2. Evaporative Refrigeration3. Air Refrigeration4. Vapour Refrigeration 5. Steam-jet Refrigeration6. Solar Refrigeration7. Liquid Gases Refrigeration
![Page 5: 134167289 Solar Refrigeration Ppt](https://reader035.fdocuments.net/reader035/viewer/2022081414/55cf9a96550346d033a276b3/html5/thumbnails/5.jpg)
In the solar refrigeration system we take a solar energy from sun and to convert solar energy into electrical energy. This Electrical energy we use in Refrigerator.
The solar energy is used for many purpose as Drying, Power Generation, Melting in Addition to Heating & Cooling.
![Page 6: 134167289 Solar Refrigeration Ppt](https://reader035.fdocuments.net/reader035/viewer/2022081414/55cf9a96550346d033a276b3/html5/thumbnails/6.jpg)
Solar energy needs no conversion & on the other hand, it helps to conserve non renewable energy sources like oil, gas, coal and Nuclear fuels.
Solar energy may be collected either as heat or as electricity.
There are different methods of cooling using solar energy are represented on following block diagram,………
![Page 7: 134167289 Solar Refrigeration Ppt](https://reader035.fdocuments.net/reader035/viewer/2022081414/55cf9a96550346d033a276b3/html5/thumbnails/7.jpg)
![Page 8: 134167289 Solar Refrigeration Ppt](https://reader035.fdocuments.net/reader035/viewer/2022081414/55cf9a96550346d033a276b3/html5/thumbnails/8.jpg)
The solar energy can be used either in VAPOUR
COMPRESSION REFRIGERATION or VAPOUR
ABSORPTION REFRIGERATION system.
![Page 9: 134167289 Solar Refrigeration Ppt](https://reader035.fdocuments.net/reader035/viewer/2022081414/55cf9a96550346d033a276b3/html5/thumbnails/9.jpg)
![Page 10: 134167289 Solar Refrigeration Ppt](https://reader035.fdocuments.net/reader035/viewer/2022081414/55cf9a96550346d033a276b3/html5/thumbnails/10.jpg)
Solar energy could be converted directly into mechanical work for operating conventional compressor of a conventional vapour compression refrigeration system.
The shaft work to the compression was provided by a steam turbine supplied with a steam which was generated by a steam generator placed at the focus of a large parabolic mirror.
The COP of the system was found to be about 30% of the values for an idle system for the temperature values considered.
![Page 11: 134167289 Solar Refrigeration Ppt](https://reader035.fdocuments.net/reader035/viewer/2022081414/55cf9a96550346d033a276b3/html5/thumbnails/11.jpg)
Rankine cycle conversion of solar energy into mechanical power is more complex than absorption cycle directly driven by solar heat. There fore, not much work has been done in developing the rankine cycle for the use of vapour compression system.
In this system cooling tower are not generally acceptable because of lack of water.
Air cooled condensers are an alternative but the ambient temperature rises to 50’c and therefore the condenser designed becomes critical.
![Page 12: 134167289 Solar Refrigeration Ppt](https://reader035.fdocuments.net/reader035/viewer/2022081414/55cf9a96550346d033a276b3/html5/thumbnails/12.jpg)
COP falls considerably as high compression ratio is essential to carry out the condensation above 50’c.
The refrigerant vapours are formed using the heat collected by solar concentrators and passed through a high speed turbines which runs a centrifugal compressor of the conventional refrigeration cycle.
A small electric motor is mounted on the same shaft to provide stand by compressor power and to serve as a alternator when the compressor is idle but the sun is shining.
![Page 13: 134167289 Solar Refrigeration Ppt](https://reader035.fdocuments.net/reader035/viewer/2022081414/55cf9a96550346d033a276b3/html5/thumbnails/13.jpg)
![Page 14: 134167289 Solar Refrigeration Ppt](https://reader035.fdocuments.net/reader035/viewer/2022081414/55cf9a96550346d033a276b3/html5/thumbnails/14.jpg)
![Page 15: 134167289 Solar Refrigeration Ppt](https://reader035.fdocuments.net/reader035/viewer/2022081414/55cf9a96550346d033a276b3/html5/thumbnails/15.jpg)
CIRCUIT 1.
This provides the hot water which is collected
from the solar collector. This water is used for
generating refrigerant vapour in the refrigerant
boiler. An auxiliary hot water boiler is provided
to compensate the heat required when solar
energy is not sufficient or not available due to
cloudy sun or during rains.
![Page 16: 134167289 Solar Refrigeration Ppt](https://reader035.fdocuments.net/reader035/viewer/2022081414/55cf9a96550346d033a276b3/html5/thumbnails/16.jpg)
CIRCUIT 2.
This circuit is used to generate mechanical power which is use to run the compressor of refrigeration circuit. This power generating circuit consist of generator, turbine, condenser and a pump.
The hot water from the collector is used to vaporise the organic fluid in the refrigerant generator. The vaporised fluid drives the turbine which drives the compressor of the refrigeration cycle. The vapour coming out at lower pressure from turbine is condensed in the condenser and pumped back to the refrigerant boiler.
![Page 17: 134167289 Solar Refrigeration Ppt](https://reader035.fdocuments.net/reader035/viewer/2022081414/55cf9a96550346d033a276b3/html5/thumbnails/17.jpg)
CIRCUIT 3.
This is conventional vapour compression refrigeration cycle which works on reversed rankine cycle. This circuit consist of compressor, condenser, expansion valve and evaporator.
An advantage of using refrigerant in the power cycle is low grad heat which can be used to generate the vapour….
But the disadvantage is thermal effinciency is very poor.
![Page 18: 134167289 Solar Refrigeration Ppt](https://reader035.fdocuments.net/reader035/viewer/2022081414/55cf9a96550346d033a276b3/html5/thumbnails/18.jpg)
Since we can convert solar energy more
efficiently to heat than the mechanical or
electrical energy the use of absorption
refrigeration system with solar energy seem to
be the best solution at present time.
![Page 19: 134167289 Solar Refrigeration Ppt](https://reader035.fdocuments.net/reader035/viewer/2022081414/55cf9a96550346d033a276b3/html5/thumbnails/19.jpg)
![Page 20: 134167289 Solar Refrigeration Ppt](https://reader035.fdocuments.net/reader035/viewer/2022081414/55cf9a96550346d033a276b3/html5/thumbnails/20.jpg)
A generator contains an ammonia water mixture
with strong concentration of refrigerant.
A generator may be consider as a heat exchanger
with heat transport liquid on one side and boiling
two phase flow on the other. In the generator,
ammonia and water vapour are boiled off from
the strong mixture in the upper part of the
generator. This vapour leaving the generator
may contain from 5 to 10% of water vapour.
![Page 21: 134167289 Solar Refrigeration Ppt](https://reader035.fdocuments.net/reader035/viewer/2022081414/55cf9a96550346d033a276b3/html5/thumbnails/21.jpg)
The vapour coming out of generator is liquefied
in the condenser and led to the refrigerant
storage. The conveying of warm condensate
from the condenser into the evaporator through
throttling valve causes a reduction in
refrigeration effect. Therefore a heat exchanger
is inserted between the storage and evaporator
to decrease the temperature of the liquid
refrigerant.there by the refrigeration effect by
recovering heat which would otherwise be lost.
![Page 22: 134167289 Solar Refrigeration Ppt](https://reader035.fdocuments.net/reader035/viewer/2022081414/55cf9a96550346d033a276b3/html5/thumbnails/22.jpg)
The refrigerant which is at low temperature , low pressure is evaporated by absorbing the heat from the air or water which is circulated in the evaporator. This cooled air or water is further used either for refrigeration or air conditioning according to requirement.
The absorber is considered as an indirect heat exchanger with cooling water flowing on one side and weak mixture flowing from the generator on the other side.
![Page 23: 134167289 Solar Refrigeration Ppt](https://reader035.fdocuments.net/reader035/viewer/2022081414/55cf9a96550346d033a276b3/html5/thumbnails/23.jpg)
A pressure reduction valve between the generator and absorber reduces the pressure from high generator pressure to a lower one in the absorber.
A liquid to liquid heat exchanger is used in the circuit in between absorber and generator which transfer energy from the weak hot liquid coming out from generator to the strong cooled liquid coming out of absorber.
![Page 24: 134167289 Solar Refrigeration Ppt](https://reader035.fdocuments.net/reader035/viewer/2022081414/55cf9a96550346d033a276b3/html5/thumbnails/24.jpg)
![Page 25: 134167289 Solar Refrigeration Ppt](https://reader035.fdocuments.net/reader035/viewer/2022081414/55cf9a96550346d033a276b3/html5/thumbnails/25.jpg)
The basic philosophy behind the development
of the cycle has been that the system should
not be dependent on energy sources other than
solar radiation and it should be simple so that
there would be virtually no need for service or
maintenance during the life time of the plant. in
addition to this, it would be also desirable if the
operation of the system is made fully
automatic.
![Page 26: 134167289 Solar Refrigeration Ppt](https://reader035.fdocuments.net/reader035/viewer/2022081414/55cf9a96550346d033a276b3/html5/thumbnails/26.jpg)
The solid absorption cycle is the answer to all the above mentioned requirement.
The pumps and blowers are also ruled out as well as no electrical control devices are required.
An intermittent absorption cycle is very well suited to the diurnal cycle of the sun.
A solid absorption cycle with NH3 as refrigerant and calcium chloride as the absorbent came out as the best solution for the requirements.
![Page 27: 134167289 Solar Refrigeration Ppt](https://reader035.fdocuments.net/reader035/viewer/2022081414/55cf9a96550346d033a276b3/html5/thumbnails/27.jpg)
The solid absorption cycle is based on the ability of metal halides to form complexes with certain gases, especially NH3. For refrigeration, chloride of calcium is well suited. It absorbs 8 moles of NH3 of which 6 can be driven off at temperature around 100*c.
For condensing temperature of 40*c the dotted lines to the right indicate equilibrium deabsorption temperature of 94*c & 106*c respectively.
![Page 28: 134167289 Solar Refrigeration Ppt](https://reader035.fdocuments.net/reader035/viewer/2022081414/55cf9a96550346d033a276b3/html5/thumbnails/28.jpg)
The heats of reaction are nearly equal for the above mentioned two steps and almost twice the latent heat of vaporization. This states that the COP of the cycle can not be more than 0.5.
Another absorbent used in chloride of strontium from which 7 moles of NH3 out of 8 can be driven off which is an advantage over calcium chloride but it is very costly compared with calcium chloride.
![Page 29: 134167289 Solar Refrigeration Ppt](https://reader035.fdocuments.net/reader035/viewer/2022081414/55cf9a96550346d033a276b3/html5/thumbnails/29.jpg)
It has no moving parts so it does not require any maintenance.
It has no problem to obtain evaporation temperature -10 to -15 oC.
The efficiency of the cycle is not very sensitive to high condensing temperature like other system.
A gravity driven evaporation/condensation loop is the only feasible solution that will lend itself easily to an automatic operation. This is only possible with this cycle.
![Page 30: 134167289 Solar Refrigeration Ppt](https://reader035.fdocuments.net/reader035/viewer/2022081414/55cf9a96550346d033a276b3/html5/thumbnails/30.jpg)
This system is well suitabled for freezing of ice in the form of block ice or in an ice bank tank.
The former can be used in crushed form for preservation of agricultural produce, meat and fish.