TCH assign failure congestion
Problem detection:
TCH assign. Congestion max. > 2 % (Critical , action needed)
TCH Load BH (Erlang / capacity ) > 90 % (forecast)
Investigation:
Check for hardware availability bycomparing:RTCH_nb (TCRRN) withRTCH_available_avg (TCAVAN)
Any TRXsdown or not
carryingtraffic?
Report to BSS support
team
Any neighborsite(s) down
not carryingtraffic?
Check through thematic map
TCH load BH on cell neighbors.
HO Inc congestion on neighbors.
All neighbors
are loaded(> 80%) + High
Inc HOcon estion
Request for upgrades,Calculate # of combiners needed and check with
RNP if there will be no coverage problem ifadditional combiner is used
Request for Densification sites
RNP
Check with RNP if
planned coverage
overlap with
neighbors is sufficient
for smooth HO flow.
Densification sites needed
Check better condition parameters for each
couple.
Check High HO Inc execution failure onneighbors, if yes follow same investigation in
call drop HO sheet.
Check through drive test (RMS) coverage for
serving loaded cell vs. neighbor free cell.
Antenna optimization needed?
Hardware check needed?
Traffic sharing
Enable FDR on serving cell
Enable Traffic HO for each couple and adjust
relevant parameters according to drive test
analysis. (or leave default values according to # of
TRX)
Enable Fast traffic HO, but monitor HO/callrate and call drop HO specially for cells with
many inter BSC adjacencies
Yes
NO
NO Yes
Yes
NO
NO
Yes
![Page 2: 131376877 ERICSSON Optimization Guide](https://reader036.fdocuments.net/reader036/viewer/2022081801/577ca6291a28abea748bc876/html5/thumbnails/2.jpg)
8/20/2019 131376877 ERICSSON Optimization Guide
http://slidepdf.com/reader/full/131376877-ericsson-optimization-guide 2/5
![Page 3: 131376877 ERICSSON Optimization Guide](https://reader036.fdocuments.net/reader036/viewer/2022081801/577ca6291a28abea748bc876/html5/thumbnails/3.jpg)
8/20/2019 131376877 ERICSSON Optimization Guide
http://slidepdf.com/reader/full/131376877-ericsson-optimization-guide 3/5
![Page 4: 131376877 ERICSSON Optimization Guide](https://reader036.fdocuments.net/reader036/viewer/2022081801/577ca6291a28abea748bc876/html5/thumbnails/4.jpg)
8/20/2019 131376877 ERICSSON Optimization Guide
http://slidepdf.com/reader/full/131376877-ericsson-optimization-guide 4/5
![Page 5: 131376877 ERICSSON Optimization Guide](https://reader036.fdocuments.net/reader036/viewer/2022081801/577ca6291a28abea748bc876/html5/thumbnails/5.jpg)
8/20/2019 131376877 ERICSSON Optimization Guide
http://slidepdf.com/reader/full/131376877-ericsson-optimization-guide 5/5
Call drop HO
Problem detection:
1. High call drop rate on the cell > 1 %.
2. % HO drops > 30% of total dropped calls on the cell.
Investigation:
High HO out
execution failurerate? >40 %
No Yes
Majority of
failure isInter BSC?
Check for BCCH/BSICduplication in celladjacencies
For neighbors in different
OMC-R , check if relation isdefined correctly (externalcells)
Check for synchronization problems
Check neighbor plan for
unnecessary (Far) neighbor
declarations.
Yes
Check forBCCH/BSIC duplicationin cell adjacencies
Check for database
inconsistency betweenOMC-R and BSC
NO
Identify critical pair ofcells, (with Out HOdrop > 5 %) usingType 26 (on demand
counter)
High% ROC?
Check DL Qual / UL Qualon target cell to locate
interference problem.
Check DL Lev /UL Lev on
target cell for coverage problem
Check DL Qual / UL Qual on both serving & target cell to locateinterference problem.
Check DL Lev /UL Lev on both
serving & target cell for coverage problem
Yes
NO
Good % of better
condition (>40%)
Yes
NO
*Check better conditions
parameters.*Check for severe
interference on serving cell
* Check for coveragecontinuity