1252-Transducer Engineering Question Paper

7
B.E. DEGREE EXAMINATION. Fourth Semester Electronics and Instrumentation Engineering EI 235/IT 237 — TRANSDUCER ENGINEERING (Common to Instrumentation and Control Engineering and Instrumentation Engineering) Time : Three hours Maximum : 100 marks Answer ALL questions. PART A — (10 ? 2 = 20 marks) 1. Why is periodical calibration of measuring instrument necessary? 2. List any two sources of systematic error in a measuring instrument. 3. What is the difference between accuracy and precision? 4. What is the 5% settling time in the step response of a first–order instrument with a time–constant of 12 sec.? 5. What is meant by self–heating error in a resistance thermometer? 6. Why is dynamic compensation network used with hot–wire anemometers? 7. Mention the problem that occurs when phase insensitive demodulator is used with LVDT. 8. Sketch the desired frequency response of a capacitor microphone. 9. Give the material and sensitivity of IC temperature sensor. 10. Mention two advantages of smart sensor. PART B — (5 ? 16 = 80 marks) 11. (i) Define standard. How are standards classified? Give the international standards used for mass, length, and time. (8)

Transcript of 1252-Transducer Engineering Question Paper

Page 1: 1252-Transducer Engineering Question Paper

B.E. DEGREE EXAMINATION.Fourth Semester

Electronics and Instrumentation EngineeringEI 235/IT 237 — TRANSDUCER ENGINEERING

(Common to Instrumentation and Control Engineering and Instrumentation Engineering)

Time : Three hours Maximum : 100 marksAnswer ALL questions.

PART A — (10 ? 2 = 20 marks)

1. Why is periodical calibration of measuring instrument necessary?2. List any two sources of systematic error in a measuring instrument.3. What is the difference between accuracy and precision?4. What is the 5% settling time in the step response of a first–order instrument with a time–constant of 12 sec.?5. What is meant by self–heating error in a resistance thermometer?6. Why is dynamic compensation network used with hot–wire anemometers?7. Mention the problem that occurs when phase insensitive demodulator is used with LVDT.8. Sketch the desired frequency response of a capacitor microphone.9. Give the material and sensitivity of IC temperature sensor.10. Mention two advantages of smart sensor.

PART B — (5 ? 16 = 80 marks)

11. (i) Define standard. How are standards classified? Give the international standards used for mass, length, and time. (8)

(ii) Ten measurements of a pressure made by an instrument at different time intervals give the following readings in kg/cm2 : (8)7.92, 8.03, 8.10, 7.95, 8.01, 7.98, 7.95, 8.07, 7.94 and 7.97.Find arithmetic mean, standard deviation, and most probable error.

12. (a) (i) Define sensitivity and resolution of a measuring instrument. (4)(ii) What are the three ways of specifying the non–linearity of an instrument? (4)(iii) A first–order thermometer with a time–constant of 5 sec is used to measure the temperature of a furnace fluctuating between 540?C and 580?C in a sinusoidal manner. The frequency of fluctuation is 0.04 Hz. Find the maximum and minimum readings of the thermometer. (8)

Or

(b) (i) Derive an expression for the output of a first–order instrument when subjected to unit impulse input. Also sketch the response. (8)(ii) The gas pressure inside a vessel starts increasing from the initial value of 100

Page 2: 1252-Transducer Engineering Question Paper

kPa at the rate of 2000 Pa/sec. The pressure is measured by a second–order instrument with a damping ratio of 0.7 and a natural frequency of 30 Hz. Sketch the input and output variation with time and find the steady–state error in instrument reading after transient in output has vanished. (8)

13. (a) (i) Give the construction details of bonded and unbonded strain gauges. Explain any two applications of bonded strain gauges. (8)(ii) A resistance potentiometer with a 20 mm travel has a resistance of 10,000 Ohms. It is connected to a 10 V d.c. source with negligible internal resistance. Calculate the actual displacement when the output of the potentiometer is 5 V. The resistance of the voltmeter is 20,000 Ohms. (8)

Or

(b) (i) Explain with a sketch the construction details and characteristics of a piezo resistive pressure transducer. (8)(ii) Describe the temperature Vs resistance characteristic of a thermistor with equation. Explain any one method of linearizing thermistor characteristic. (8)14. (a) (i) Explain with a sketch the principle of operation of a variable reluctance accelerometer. (8)(ii) Five square plates of area 16 cm2 (each) are arranged as shown in Fig. 14(a). The plate spacings are 0.2 mm (each). The arrangement is to be used as a displacement transducer by observing change in capacitance with distance x. Calculate the sensitivity of this device in . (8)

Fig. 14(a)

Or

(b) (i) Draw the input–output characteristic of LVDT. Explain the phase adjustment circuits and null–reduction technique used for LVDT. (8)(ii) Explain with a sketch the construction details, principle of operation and signal conditioning circuits of a capacitive transducer used for differential pressure measurement. (8)

15. (a) (i) Define the two sensitivity constants of piezo electric transducer. Derive the relation between the two constants. Also draw the equivalent circuit of piezoelectric transducer. (8)(ii) Explain with a sketch the working of an encoder that gives 4–bit digital output proportional to linear displacement. Mention the advantages of digital transducers. (8)

Or

(b) (i) Define magnetostrictive effect. Name two materials used in magnetostrictive transducers. Describe any one application of magnetostrictive

Page 3: 1252-Transducer Engineering Question Paper

transducer. (8)(ii) Explain with a sketch the working of a fiber–optic displacement transducer. Draw its input–output characteristic. (8)———————

Page 4: 1252-Transducer Engineering Question Paper

B.E/B.Tech. DEGREE EXAMINATION, MAY/JUNE 2007Fourth semester

Instrumentation and Control Engineering.EI 1252-TRANSDUCER ENGINEERING

(Common to Electrical and Instrumentation Engineering)(Regulation 2004)PART –A(10*2=20)

1. State the classification of standards.2. What is need for calibration?3. What is the value of damping ratio consideration for transducers meant to measure temperature?4. How is linearity of a transducer specified?5. Define gauge factor.6. State the principle of operation of hotwire anemometer.7. How to minimize null voltage in LVDT?8. Name the transducer used for angular position telemetry.9. State the principle of operation of Fiber optic sensor.10. What is charge amplifier?

PART-B-(5*16=80)

11.(a) (i) explain the classification of transducers. (8)(ii) one hundred temperature reading were taken at small intervals of time and recorded to the nearest 0.5°C. The frequency of occurrences of the reading is given below:

Temperature reading °C 98.5 99 99.5 100 100.5 101.0 101.5

Frequency 4 13 19 35 17 10 02Calculate:(1) Arithmetic mean(2) Average deviation (3) Standard deviation (4) Probable errorOr

(b) (i) write the significance of odds and uncertainty. (6)(ii) Write the causes and methods to minimize the different classes of errors. (10)

12.(a) (i) a measure system has an exponential response to step input. The time constant of the system is 3 seconds. What is the time required to reach (1) 60 percent and (2) 80 percent of final steady state reading? (8)(ii) Derive the transfer function of first order instrument. Obtain the output of the first order transducer for a given unit impulse input. (8)

Or

Page 5: 1252-Transducer Engineering Question Paper

(b) Distinguish the following static characteristics of transducers:(i) Input impedance vs. output impedance(ii) Resolution vs. accuracy(iii) Accuracy vs. precision(iv) Threshold vs. resolution (16)

13. (a) (i) derive the expression for gauge factor. (6)(ii) A strain gauge has a gauge factor of 4.if the strain gauge is attached to a metal barthat stretches from 0.28 m to 0.285m when strained, what is the percentage change in resistance? If the unstrained value of gauge is 350 ohms, what is the resistance value of gauge after the application of the strain? (6)(iii) Distinguish metal wire and semiconductor strain gauges. (4)

Or

(b) Explain the construction and working and signal conditioning circuits of resistance thermometers with temperature compensation. (16)

14. (a) explain the construction and operation of: (i) A variable reluctance transducer (8)(ii) Synchros (8)

Or

(b) Explain the construction and operation of (i) A capacitance transducer used for measurement of displacement (8)(ii) Capacitance microphone (8)

15.(a) write short notes on:(i) Piezoelectric accelerometer (8)(ii) Digital encoder (8)

Or

(b) Write short notes on:(i) Smart sensor (8)(ii)IC sensor of measurement (8)