4
ChargeGuard Series Spin-On Filters Global Filtration Technology 47

Transcript of 1250at 01 1 - gpa.ugatu.su fileParker Hannifin Corporation Hydraulic Filter Division Metamora, OH...

ChargeGuard™ SeriesSpin-On Filters

Global Filtration Technology47

Parker Hannifin CorporationHydraulic Filter DivisionMetamora, OH

Spin-On FiltersChargeGuard™ Series

1.38 (35.1)3/8″-16 UNC-2Bx .60 (15.2)MIN. FULL THREAD,4 PLACES

3/8″-16 UNC-2Bx .69 (17.5)MIN. FULLTHREAD,4 PLACES

1.38 (35.1)

1.13(28.7)

VISUALINDICATOR

TYPE BELECTRICALINDICATOR

2.40 (61.0)

4.59 (116.6)

������������

2.20 (55.9)

5.09 (129.3)

��� ����

2.55 (64.8)

1.38 (35.1)

2.75 (69.9)

4.00 (101.6)

3.7 (94)

CANISTER THREAD1-3/8″ - 12 UNF-2B

������������

.91 (23.1)MIN.ELEMENTSERVICECLEARANCE

INLET

1.34(34.0)STD.HEAD

1.88(47.8)

T12HEAD

C

L

2010

0.68

6

4

2

00 5 10 15 20 25 30 35

40 60 80 100 120

0.5

0.4

0.3

0.2

0.1

����

���������� ���

��������������

∆����

���

∆����

��

CG46

-5

CG46-CC5

CG46-CC16

CG46-CC22

2010

0.68

6

4

2

00 5 10 15 20 25 30 35

40 60 80 100 120

0.5

0.4

0.3

0.2

0.1

����

���������� ���

��������������

∆����

���

∆����

��

CG49-5

CG49-CC22CG49-CC16

CG49-CC5

2010

0.68

6

4

2

00 5 10 15 20 25 30 35

40 60 80 100 120

0.5

0.4

0.3

0.2

0.1

������������

���������� ���

��������������

∆����

���

∆����

��

S12 AND T12 PORTS

N16 AND S16 PORTS

DimensionsInches (mm)

Feature/Applications for

Spin-On Filters

DIMENSIONS CG FILTER MODELINCHES (MM) 46 49

C 6.0 (152) 9.4 (239)

L 8.5 (216) 11.9 (302)

48

� Charge pump

� Pressure line

� Return line applications

� Disposable element

� Quick and easy servicing

� BetaMaze long life elements

� Rated Working Pressure 500 PSI

� Rated Static Pressure 1000 PSI

� Flows to 35 GPM

� 5 Micron to 22 MicronAbsolute Elements

Parker Hannifin CorporationHydraulic Filter DivisionMetamora, OH

Spin-On FiltersChargeGuard™ Series

Installation andSpecification DataChargeGuard Series

Material:Head – Cast Aluminum AlloyCanister – SteelSeals – Nitrile (Standard)

Pressure Rating:Static pressure: 1000 psi (70 bar)Per NFPA/T2.6.1, 1974, category 1/90Working pressure: 500 psi (35 bar)

Canister Fatigue Strength Rating:100,000 Cycles 0-500-0 psid (0-35-0 bar)300,000 Cycles 0-400-0 psid (0-28-0 bar)1,000,000 Cycles 0-350-0 psid (0-24-0 bar)

Temperature Range:Cellulose Media -20°F to 225°F (-30°C to 107°C)BetaMaze Media -20°F to 250°F (-30°C to 120°C)

Assembly Weight:CG46 - 3.5 lbs. (1.6 kg); CG49 - 5.3 lbs. (2.4 kg)

Indicator SpecificationData ChargeGuard Series

Electrical Type-B:• DC Single Post• Voltage: 6-30 VDC Max.• Current: 200 ma Max.• Circuit: Normally open• Ground: Through filter head

Electrical Type-E:• AC/DC 3-Wire• Voltage: 120 VAC Max., 100 VDC Max.• Current: 250 ma Max.• Circuit: Normally open or Normally closed

49

Element DataMultipass Test Results To ISO 4572

(Time Weighted Averages)

B2 B5 B16 B22 B40

CC5 5 2 >75 >5000 INF INF

CC16 16 – 2 >75 800 INF

CC22 22 – – 18 >75 >5000

5 17 – 2 70 600 INF

CodeNumber

AbsoluteRating

Parker Hannifin CorporationHydraulic Filter DivisionMetamora, OH

Spin-On FiltersChargeGuard™ Series

CC16

BOX 1: SIZE

Size Diameter LengthCode Inches (mm) Inches (mm)

CG46 3.7 (94) 5.9 (152)CG49 3.7 (94) 9.4 (239)

BOX 2: ELEMENT

Cellulose Betamaze5 Micron 5 Micron 16 Micron 22 MicronNominal Absolute Absolute Absolute

BETA 5 ≥≥≥≥≥ 2 BETA 5 ≥≥≥≥≥ 75 BETA 16 ≥≥≥≥≥ 75 BETA 22 ≥≥≥≥≥ 75

5 CC5 CC16 CC22

BOX 3: PORTSymbol Description

S12 SAE12 (1-1/16″-12)

T12 SAE12 (1-1/16″-12)w/3rd Port - 50 PSIDBypass to Tank

S16 SAE16 (1-5/16″-12)

BOX 4: BYPASSSymbol Description

B Blocked

25 25 PSID

50 50 PSID

BOX 5: INDICATORSymbol Description

V Visual DifferentialPressure Indicator

B Electrical DifferentialPressure IndicatorDC Single Post

E Electrical DifferentialPressure IndicatorAC/DC 3-Wire

Omit If Not Required

NOTE: Facing the inlet port with thecanister down, the standard mountingposition for the visual differential pressureindicator is the left side.For other mounting options, consult thefactory.

50

HOW TO ORDER:Select the desired symbol (in the correct position) to construct a model code.Assembly Example:

BOX 1 BOX 2 BOX 3 BOX 4 BOX 5

CG46 CC16 S12 25 V

ReplacementElement Example:

BOX 1 BOX 2

CG46