1/20 Always Surpassing Customers Expectations KEYSET ADMIN.
-
Upload
gary-summers -
Category
Documents
-
view
233 -
download
0
description
Transcript of 1/20 Always Surpassing Customers Expectations KEYSET ADMIN.
1/20 Always Surpassing Customers Expectations
KEYSET ADMIN
2/20 Always Surpassing Customers Expectations
Layout of Keyset Entering Keyset Admin Menu Example Button Usage
Programming Menus Example
1. Contents
Pre-programmed Database Station Base Program CO Line Base Program System Base Program Station Group Program Installation
3/20 Always Surpassing Customers Expectations
2. Layout of Keyset
Speaker Hold/Save
Trans / Pgm Speed
4/20 Always Surpassing Customers Expectations
3. Entering Keyset Admin (1/2)
+ + ▷ Press
LCD Display will show
▷ Then Press
LCD Display will show
▷ Enter program number (e.g.100)
Admin 100 started
Trans/Pgm
Trans/Pgm
ADMIN PROGRAM START
BACK DELETE SAVE
To enter Admin Programming
ENTER PGM NUMBER
BACK DELETE SAVE
LOCATION PROGRAMPRESS FLEX_KEY (1-2)BACK DELETE SAVE
With default values, station 100 can enter admin program.
5/20 Always Surpassing Customers Expectations
Press
Station will go to the idle state.
ON/OFF =
3. Entering Keyset Admin (2/2)
To exit Admin Programming
STATION 100 (T)28 AUG 06 02:01 pmPICKUP CONF REDIAL
6/20 Always Surpassing Customers Expectations
4. Button Usages
Trans/Pgm
Speed
[TRANS/PGM] will move you to the start menu.
[HOLD/SAVE] will store the value.Hold/Save
Volume [Volume Up/Dn] is used to scroll the data up and down.
[SPEED] is used to delete current data.
Flexible buttons are used to select menus.
1
Soft menu is used to go back / delete / save.
[BACK] will move you back to the upper step.
Numeric data is entered from keypad.
7/20 Always Surpassing Customers Expectations
MAIN MENU PGM ITEM
100 Location Program
101 Board Assignment
103 Logical Slot Assignment
104 Numbering Plan Type
105 Flexible Number Plan – Station Number
106 Flexible Number Plan A
107 Flexible Number Plan B
108 IP Setting
PRE-PROGRAMMED DATABASE
109 Flexible Number Plan C
STATION BASE PROGRAM 110 Station ID
111 Station Attribute 1
112 Station Attribute 2
113 Station Attribute 3
114 Station Attribute 4
115 Flex Button Assignment
116 Station COS
117 CO Line Group Access
118 Internal Page Zone
119 Conference Page Zone
120 ICM Tenancy Group
121 Preset Call Forward
122 Hot/Warm Line Selection
124 SMDR Account Group
125 Copy DSS Button
126 Station IP List
130 Display Stations by COS
131 Display Stations by CO Group Access
5. Program Menu (1/4)
: Needs to be Restart
8/20 Always Surpassing Customers Expectations
5. Program Menu (2/4)MAIN MENU PGM ITEM
140 CO Service Type 141 CO Line Attribute I 142 CO Line Attribute II 143 ISDN CO Line Attribute I 144 CO Ring Assignment 145 CO Ring Assignment Display 146 CO Line Attribute III
CO LINE BASE PROGRAM
147 CO CID Attribute SLOT BASE PROGRAM 155 Slot Attribute
160 System Attribute – I 161 System Attribute – II 162 Admin Password 163 Alarm Attributes 164 Attendant Assignment 165 Auto Attendant VMIB Annc. Assignment 166 CO-to-CO COS 167 DID/DISA Destination 168 External Control Contact 169 LCD Date/Time/Language Display Mode 170 Modem 171 Music 172 PBX Access Code 173 PLA Priority Setting 174 RS-232C Port Setting 175 Print Port Selection 176 Pulse Dial Ratio 177 SMDR Attributes 178 System Date/Time Setting 179 Linked Station Pairs Table 180 System Timers – I 181 System Timers – II 182 System Timers – III
SYSTEM BASE PROGRAM
183 In Room Indication 184 Chime Bell Attribute
9/20 Always Surpassing Customers Expectations
MAIN MENU PGM ITEM
DCOB 186 DCOB System attribute
187 DCOB CO Line Attribute STATION GROUP 190 Station Group Assign
191 Station Group Attribute CLI PROGRAM 200 ISDN Attributes
201 COLP Table
TABLES 204 Local Code Table
220 LCR Attributes
221 LCR – Leading Digit Table
222 LCR – Digit Modification Table
223 LCR Table Initialization
224 Toll Exception Table
225 Canned Toll Table
226 Emergency Code Table
227 Authorization Code Table
228 Customer Call Routing
229 Executive/Secretary Table 231 Flexible DID Conversion Table 232 System Speed Zone 233 Weekly Time Table 234 Voice Mail Dialing Table 236 Mobile Extension Table
NETWORKING 320 Networking Basic Attribute
321 Networking Supplementary Attribute
322 Networking CO Line Attribute
324 Networking Numbering PlanTable VOIB 340 VOIB IP Setting
341 Gateway Attribute
5. Program Menu (3/4)
10/20 Always Surpassing Customers Expectations
MAIN MENU PGM ITEM
IP PHONE PROGRAM 380 VOIB Slot for IP Phone 381 IP Phone Number Assign 382 RSG/IP Phone Attribute 386 IP Phone Attribute 396 IP Phone RX Gain 397 IP Phone TX Gain NATION SPECIFIC 400 DTIB Rx Gain Control
401 SLIB Rx Gain Control 402 SLIB12 Rx Gain Control 403 WTIB Rx Gain Control 404 ACOB Rx Gain Control 405 ACOB8 Rx Gain Control 406 DCOB Rx Gain Control 407 VMIB Rx Gain Control 408 DTMF Receiver Rx Gain Control 409 EXT Page Rx Gain Control 410 CPTU Rx Gain Control 411 Modem Rx Gain Control 412 Short SLIB Gain Control 413 Long SLIB Gain Control 414 Far SLIB Gain Control 415 Short ACO Gain Control 416 Long ACO Gain Control 420 System Tone Frequency 421 Differential Ring Frequency 422 Distinct CO Ring Frequency 423 ACNR Tone Cadence INITIALIZATION (DB INIT) 450 Initialization PRINT DATABASE 451 Print Prot Database
5. Program Menu (4/4)
11/20 Always Surpassing Customers Expectations
- Press Flex_1 to set Nation Code To change Nation Code, DIP4 should be set to ON.
- Press Flex_2 to set Site Name Enter Site Name from Keypad.
6. Example
PRE-PROGRAMMED DATABASE
LOCATION PROGRAMPRESS FLEX_KEY (1-2)BACK DELETE SAVE
▷ Location Program ( PGM 100 )
NATION CODEPROTECTED DATABASE(DIP4)BACK DELETE SAVE
SITE NAMEHEAD OFFICEBACK DELETE SAVE
12/20 Always Surpassing Customers Expectations
ADDITIONAL BOARD ASSIGNMENT
SLOT 06 (F1:ID F2:DEVS)ID:UNKNOWN DEVS:0BACK DELETE SAVE
6. Example
2. Enter 2 digits of Slot number you want to program. (e.g. slot 06)
BKSU
EKSU
VMIU, AAFU VOIB
12
56
34
78
9 10
2. CO
3. Others
1. Extension
BOARD ASSIGNMENTENTER SLOT NUMBERBACK DELETE SAVE
1. Enter PGM 101 by pressing [Trans/Pgm] + ‘*’ + ‘#’ + ‘101’ at Admin Keyset
▷ BOARD ASSIGNMENT(PGM101) & LOGICAL SLOT ASSIGN(PGM 103)
13/20 Always Surpassing Customers Expectations
6. Example
3. Press Flex_1 and enter 2 digits Board ID code (e.g. 41 for VOIB)
STA CODE COL CODE Etc CODE
SLIB16SLIB8
HYBRID
131417
LCOB3E1IB8VOIB
334041
VMIUAAFU
6465
SLOT 06 (F1:ID F2:DEVS)ID:UNKNOWN DEVS:0BACK DELETE SAVE
4. Press Flex_2 and enter device number and press [SAVE]. (e.g. 20 for E1HB8)
SLOT 10 (F1:ID F2:DEVS)ID:DCOB DEVS:20BACK DELETE SAVE
14/20 Always Surpassing Customers Expectations
LOGICAL SLOT ASSIGNCOL STA VMIBBACK DELETE SAVE
6. Example
5. Enter PGM 103 by pressing [Trans/Pgm] + ‘*’ + ‘#’ + ‘103’ at Admin Keyset
05 07 . . . . . . . . . . . . . . . . . . . .BACK DELETE SAVE
6. Press Flex_1 for COL logical slot assignment
05 07 06 . . . . . . . . . . . . . . . . . .BACK DELETE SAVE
7. Enter new slot order including slot 06 and Press [SAVE]. (e.g. 050706)
8. Restart the system.
15/20 Always Surpassing Customers Expectations
- Enter Station range you want to select (e.g. 100110)
- Press Flex_1 to set Auto Speaker option
- Dial 1/0 and Press [Hold/Save] to save data- If you exit without save, the data is not changed.
6. Example
STATION BASED PROGRAM
STATION ATT 1ENTER STA RANGE BACK DELETE SAVE
▷ Station Attribute 1 ( PGM 111 )
100-110 STATION ATT1PRESS FLEX_KEY (01-24)BACK DELETE SAVE
100-110 AUTO SPKR(1:ON/0:OFF) : ONBACK DELETE SAVE
16/20 Always Surpassing Customers Expectations
6. Example
CO LINE BASED PROGRAM
- Enter CO line range you want to select (e.g. 0103)
- Press Flex_1 to set CO Line Group
- Enter desired CO Group number with 2 digits and press [Hold/Save] button.- If you exit without save, the data is not changed.
CO LINE ATT 1ENTER COL RANGE BACK DELETE SAVE
▷ CO Line Attribute 1 ( PGM 141 )
01- 03 CO LINE ATT1PRESS FLEX_KEY (01- 10)BACK DELETE SAVE
01- 03 CO LINE GRP(00 - 25) : 01BACK DELETE SAVE
17/20 Always Surpassing Customers Expectations
6. Example
SYSTEM BASED PROGRAM
- Press Flex_4 to set DISA Retry Count.
- Enter desired retry count number with 1 digits and press [Hold/Save] button.- If you exit without save, the data is not changed.
SYSTEM ATT 1PRESS FLEX_KEY (01 – 20) BACK DELETE SAVE
▷ System Attribute 1 ( PGM 160 )
DISA RETRY CNT(0 - 9) : 3BACK DELETE SAVE
18/20 Always Surpassing Customers Expectations
6. Example
STATION GROUP PROGRAM
- Enter Station Group number(620).
- Press FLEX_1 to select Station Group type.
- After set station group type, press FLEX_3 to assign member.
- Enter station range.- If you want to enter stations one by one, enter station number after press Flex key(1~4).- You can scroll up/dn to see whole of the members if their are more than 4.
STATION GRP ASSIGNENTER HUNT NO(620-629) BACK DELETE SAVE
▷ Station Group Assign ( PGM 190 )
STATION GRP 620F1:TYPE F2:PKUP F3:MEMBACK DELETE SAVE
STATION GRP 620NOT ASSIGNED (0-6)BACK DELETE SAVE
CIRCULAR GRP 620. . . . . . . . . . . . . . . . BACK DELETE SAVE
19/20 Always Surpassing Customers Expectations
7. Practice Exercise
-Insert boards and units-Set Nationality-Initialize system as Nation Default
How to Install
20/20 Always Surpassing Customers Expectations
7. Practice Exercise
1) Insert all boards2) Power on the system (All switches of MPB are set to ‘ON’)3) Assign Nationality (PGM 100 - BTN 1) (After Assignment, please reset manually)
4) Set the DIP4 of BMBU to ‘OFF’ to preserve the programming data against reset
5) Change the numbering plan if needed (PGM 104 ~ 107)
NATION CODE 66BACK DELETE SAVE
NUMBERING PLAN(1-8)1BACK DELETE SAVE
How to Install
When restart, initial values based on current nation code are set.