12-4 Technology Drive, East Setauket, NY 11733 (631) 689-6869 (631) 689-6866 info@foosfire.com facebook System Offline Operator name Alarm Panel TYPE ID SIZE LOCATION IN SITE RISER 1 RISER 2 SIGNATURES System Online DRY RISERS Total Number of Dry Risers RISER 3 RISER 4 RISER 5 RISER 6 RISER 7 RISER 8 RISER 9 Inspector Printed Inspector - Signature Date Completed I state the information on this form is correct at the time and place of my inspection, and all the equipment tested at this time was left in operational condition upon completion of this inspection except as noted. Except as noted, the building occupancy and hazard classifications have not changed since last inspection. After this inspection, the system has been restored to normal and all panels are clear. All deficiencies and immediate actions have been explained to me and I have been informed of all necessary actions. Authorized Representative Printed Authorized Representative Signature Date Completed DRY ANNUAL INSPECTION Customer Customer W.O.# Technician Name Date of Inspection Building Name Building Street Building City/State/Zip Building ID# RISER 10 DRY VALVE INSPECTION Valves accessible and free from physical damage? No leakage from intermediate chamber? Low Air pressure signal passed test? Gauges on dry, preaction, & deluge systems in good condition? AIR PRESSURE Yes No N/A Trim Valves in appropriate position & free from leaks? Priming Water level correct? Hydraulic nameplate, if provided, securely attached? Quick opening devices passed Test? Yes No N/A FIRE DEPARTMENT CONNECTION Total Number of FDC's Visible and accessible? Plugs or Caps in place and undamaged? Caps painted as per AHJ code? Identification signs(s) in place? Ball Drip Valve in place and operating properly? Couplings & swivels not damage and rotate smoothly? Gaskets in place in good condition? Check valve is not leaking? Interior free of obstructions (if caps are not in place)? Yes No N/A Yes No N/A WATER PRESSURE Job #

Transcript of 12-4 Technology Drive, East Setauket, NY 11733 (631) 689 ... · 12-4 Technology Drive, East...

Page 1: 12-4 Technology Drive, East Setauket, NY 11733 (631) 689 ... · 12-4 Technology Drive, East Setauket, NY 11733 (631)689-6869 (631)689-6866 info@foosfire.com facebook. System Offline

12-4 Technology Drive, East Setauket, NY 11733

(631) 689-6869 (631) 689-6866

[email protected] facebook

System Offline Operator name

Alarm Panel

TYPE ID SIZE LOCATION IN SITERISER 1

RISER 2

SIGNATURES

System Online

DRY RISERS

Total Number of Dry Risers

RISER 3

RISER 4

RISER 5

RISER 6

RISER 7

RISER 8

RISER 9

Inspector Printed Inspector - Signature Date Completed

I state the information on this form is correct at the time and place of my inspection, and all the equipment tested at this time was left in operational condition upon completion of this inspection except as noted.

Except as noted, the building occupancy and hazard classifications have not changed since last inspection. After this inspection, the system has been restored to normal and all panels are clear. All deficiencies and immediate actions have been explained to me and I have been informed of all necessary actions.

Authorized Representative Printed Authorized Representative Signature Date Completed

DRY ANNUAL INSPECTION Customer

Customer W.O.#

Technician Name

Date of Inspection

Building Name

Building Street

Building City/State/Zip

Building ID#

RISER 10

DRY VALVE INSPECTIONValves accessible and free from physical damage?

No leakage from intermediate chamber?

Low Air pressure signal passed test?

Gauges on dry, preaction, & deluge systems in good condition?

AIR PRESSURE

Yes No N/ATrim Valves in appropriate position & free from leaks?

Priming Water level correct?

Hydraulic nameplate, if provided, securely attached?

Quick opening devices passed Test?

Yes No N/A

FIRE DEPARTMENT CONNECTION

Total Number of FDC's

Visible and accessible?

Plugs or Caps in place and undamaged?

Caps painted as per AHJ code?

Identification signs(s) in place?

Ball Drip Valve in place and operating properly?

Couplings & swivels not damage and rotate smoothly?

Gaskets in place in good condition?

Check valve is not leaking?

Interior free of obstructions (if caps are not in place)?

Yes No N/A Yes No N/A

WATER PRESSURE

Job #

Page 2: 12-4 Technology Drive, East Setauket, NY 11733 (631) 689 ... · 12-4 Technology Drive, East Setauket, NY 11733 (631)689-6869 (631)689-6866 info@foosfire.com facebook. System Offline

DRY VALVE TRIP TEST

MODELLOCATIONTYPE

DRY VALVE

SIZE MAKEWATER

PRESSUREAIR

PRESSURE

TRIPPINGAIR

PRESSURETRIP TIME ALARM

ACTUATE

PSI

PSI

SPRINKLERSSpare sprinklers - proper number and type, wrench?

Free of corrosion, foreign material, or paint?

Installed in proper orientation?

Free from obstructions to spray patterns?

Free from leaks and physical damaged?

Liquid in all glass bulb sprinklers?

Yes No N/APIPE Yes No N/A

In good visual condition?

No external corrosion/loads?

Free of mechanical damage and leaks?

Properly aligned?

Visible pipe hangers and seismic braces not damaged or loose?

NYC only -- Pipes / valves painted per code?

COLD WEATHER CHECK

Interior of pipe in preaction and dry pipe systems which passes through freezers free of ice blockage?

Low temperature alarms in dry pipe, preaction and deluge valve enclosures functioning?

Low points drained in dry pipe during and after trip?

Yes No N/A

CONTROL VALVE 1

CONTROL VALVE 2

CONTROL VALVE 3

CONTROL VALVE 4

CONTROL VALVE 5

CONTROL VALVE 6

PSI

PSI

PSI

PSI

PSI

PSI

PSI

PSI

PSI

PSI

PSI

PSI

PSI

PSI

PSI

PSI

3-YEAR ONLY

WATER DELIVERY TIMEMIN SEC

MAIN DRAIN VALVE 1

MAIN DRAIN VALVE 2

MAIN DRAIN VALVE 3

MAIN DRAIN VALVE 4

MAIN DRAIN VALVE 5

MAIN DRAIN VALVE 6

MAIN DRAIN VALVE 7

MAIN DRAIN VALVE 8

MAIN DRAIN VALVE 9

MAIN DRAIN VALVE 10

MAIN DRAIN VALVES

LOCATION TYPE RISER# SIZE SIGNAGEPRESSURE (PSI)

RESIDUAL STATICINITIAL

RESULTSCOMPARABLE TO PRIOR TEST

DRAINSPROPERLY

Results comparable to previous test?

Page 3: 12-4 Technology Drive, East Setauket, NY 11733 (631) 689 ... · 12-4 Technology Drive, East Setauket, NY 11733 (631)689-6869 (631)689-6866 info@foosfire.com facebook. System Offline

INSPECTOR'S TEST VALVE 1

INSPECTOR'S TEST VALVE 2

INSPECTOR'S TEST VALVE 3

INSPECTOR'S TEST VALVE 4

INSPECTOR'S TEST VALVE 5

INSPECTOR'S TEST VALVE 6

INSPECTOR'S TEST VALVE 7

INSPECTOR'S TEST VALVE 8

INSPECTOR'S TEST VALVE 9

INSPECTOR'S TEST VALVE 10

INSPECTOR'S FLOW TEST VALVES

TYPE LOCATION INSITE RISER# SIZE EASILY

ACCESSIBLE

AUDIBLEALARM

REPORTEDTIME TOALARM

SMOOTH ORIFICE

WATERFLOWDEVICES

PASS TESTSIGNAGE

TYPE LOCATION RISER # SIZE INSPECTION

OPENLEAKAGE ACCESSIBLE SIGNSSECURED

CONTROL VALVES

CONTROL VALVE 1

CONTROL VALVE 2

CONTROL VALVE 3

CONTROL VALVE 4

CONTROL VALVE 5

CONTROL VALVE 6

CONTROL VALVE 7

CONTROL VALVE 8

CONTROL VALVE 9

CONTROL VALVE 10

CONTROL VALVE 11

CONTROL VALVE 12

CONTROL VALVE 13

CONTROL VALVE 14

CONTROL VALVE 15

CONTROL VALVE 16

CONTROL VALVE 17

CONTROL VALVE 18

CONTROL VALVE 19

CONTROL VALVE 20

edwardnimocks
Sticky Note
Unmarked set by edwardnimocks
Page 4: 12-4 Technology Drive, East Setauket, NY 11733 (631) 689 ... · 12-4 Technology Drive, East Setauket, NY 11733 (631)689-6869 (631)689-6866 info@foosfire.com facebook. System Offline

12-4 Technology Drive, East Setauket, NY 11733

(631) 689-6869 (631) 689-6866

[email protected] facebook

System Offline Operator name

Alarm Panel System Online

RISER

Total Number of Wet Risers

WET ANNUAL INSPECTION Customer

Customer W.O.#

Technician Name

Date of Inspection

SIGNATURESInspector Printed Inspector - Signature Date Completed

I state the information on this form is correct at the time and place of my inspection, and all the equipment tested at this time was left in operational condition upon completion of this inspection except as noted.

Authorized Representative Printed Authorized Representative Signature Date Completed

Except as noted, the building occupancy and hazard classifications have not changed since last inspection. After this inspection, the system has been restored to normal and all panels are clear. All deficiencies and immediate actions have been explained to me and I have been informed of all necessary actions.

Building Name

Building Street

Building City/State/Zip

Building ID#

FIRE DEPARTMENT CONNECTIONTotal Number of FDC's

Visible and accessible?

Plugs or Caps in place and undamaged?

Caps painted as per AHJ code?

Identification signs(s) in place?

Ball Drip Valve in place and operating properly?

Couplings and swivels not damage and rotate smoothly?

Gaskets in place in good condition?

Check valve is not leaking?

Interior free of obstructions (if caps are not in place)?

Yes No N/A

TYPE ID SIZE LOCATION PSI

RISER 1

RISER 2

RISER 3

RISER 4

RISER 5

RISER 6

RISER 7

RISER 8

RISER 9

RISER 10

WATER BASED SYSTEM INSPECTION

Are there landlord/access issues requiring visual only?

Gauges on wet pipe system in good condition and

showing normal water supply pressure?

Alarm devices accessible?

Retard chamber/alarm drains OK?

Alarm devices free from physical damage?

Is the Audible alarm device working properly?

Hydraulic nameplate, if provided, securely attached to

riser and legible?

Valve supervisory switches indicate movement ?

Yes No N/A

Job #

Page 5: 12-4 Technology Drive, East Setauket, NY 11733 (631) 689 ... · 12-4 Technology Drive, East Setauket, NY 11733 (631)689-6869 (631)689-6866 info@foosfire.com facebook. System Offline

PIPE

In good visual condition?

No external corrosion/loads?

Free of mechanical damage and leaks?

Properly aligned?

Visible pipe hangers and seismic braces not damaged or loose?

NYC only -- Pipes / valves painted per code?

SPRINKLERS

Spare sprinklers - proper number and type, wrench?

Free of corrosion, foreign material, or paint?

Installed in proper orientation?

Free from obstructions to spray patterns?

Free from leaks and physical damaged?

Liquid in all glass bulb sprinklers?

Yes No N/A Yes No N/A

MAIN DRAIN VALVE 1

MAIN DRAIN VALVE 2

MAIN DRAIN VALVE 3

MAIN DRAIN VALVE 4

MAIN DRAIN VALVE 5

MAIN DRAIN VALVE 6

MAIN DRAIN VALVE 7

MAIN DRAIN VALVE 8

MAIN DRAIN VALVE 9

MAIN DRAIN VALVE 10

MAIN DRAIN VALVES

LOCATION TYPE RISER# SIZE SIGNAGEPRESSURE (PSI)

RESIDUAL STATICINITIAL

RESULTSCOMPARABLE TO PRIOR TEST

DRAINSPROPERLY

INSPECTOR'S TEST VALVE 1

INSPECTOR'S TEST VALVE 2

INSPECTOR'S TEST VALVE 3

INSPECTOR'S TEST VALVE 4

INSPECTOR'S TEST VALVE 5

INSPECTOR'S TEST VALVE 6

INSPECTOR'S TEST VALVE 7

INSPECTOR'S TEST VALVE 8

INSPECTOR'S TEST VALVE 9

INSPECTOR'S TEST VALVE 10

INSPECTOR'S FLOW TEST VALVES

TYPE LOCATION INSITE RISER# SIZE EASILY

ACCESSIBLE

AUDIBLEALARM

REPORTEDTIME TOALARM

SMOOTH ORIFICE

WATERFLOWDEVICES

PASS TESTSIGNAGE

Page 6: 12-4 Technology Drive, East Setauket, NY 11733 (631) 689 ... · 12-4 Technology Drive, East Setauket, NY 11733 (631)689-6869 (631)689-6866 info@foosfire.com facebook. System Offline

TYPE LOCATION RISER # SIZE INSPECTION

OPENLEAKAGE ACCESSIBLE SIGNSSECURED

CONTROL VALVES

CONTROL VALVE 1

CONTROL VALVE 2

CONTROL VALVE 3

CONTROL VALVE 4

CONTROL VALVE 5

CONTROL VALVE 6

CONTROL VALVE 7

CONTROL VALVE 8

CONTROL VALVE 9

CONTROL VALVE 10

CONTROL VALVE 11

CONTROL VALVE 12

CONTROL VALVE 13

CONTROL VALVE 14

CONTROL VALVE 15

CONTROL VALVE 16

CONTROL VALVE 17

CONTROL VALVE 18

CONTROL VALVE 19

CONTROL VALVE 20

CONTROL VALVE 21

CONTROL VALVE 22

CONTROL VALVE 23

CONTROL VALVE 24

CONTROL VALVE 25

CONTROL VALVE 26

CONTROL VALVE 27

CONTROL VALVE 28

CONTROL VALVE 29

CONTROL VALVE 30

Page 7: 12-4 Technology Drive, East Setauket, NY 11733 (631) 689 ... · 12-4 Technology Drive, East Setauket, NY 11733 (631)689-6869 (631)689-6866 info@foosfire.com facebook. System Offline

EXERCISED # OF TURNS LUBRICATED

MAINTENANCE TEST

TAMPER SIGNAL TIME TO ALARM

ANNUAL SECTION ONLY

12-4 Technology Drive, East Setauket, NY 11733

(631) 689-6866(631) 689-6869

[email protected] facebook

ANNUAL CONTROL VALVE INSPECTION

CONTROL VALVE 1

CONTROL VALVE 2

CONTROL VALVE 3

CONTROL VALVE 4

CONTROL VALVE 5

CONTROL VALVE 6

CONTROL VALVE 7

CONTROL VALVE 8

CONTROL VALVE 9

CONTROL VALVE 10

CONTROL VALVE #

CONTROL VALVE 11

CONTROL VALVE 12

CONTROL VALVE 13

CONTROL VALVE 14

CONTROL VALVE 15

CONTROL VALVE 16

CONTROL VALVE 17

CONTROL VALVE 18

CONTROL VALVE 19

CONTROL VALVE 20

CONTROL VALVE 21

CONTROL VALVE 22

CONTROL VALVE 23

CONTROL VALVE 24

CONTROL VALVE 25

CONTROL VALVE 26

CONTROL VALVE 27

CONTROL VALVE 28

CONTROL VALVE 29

CONTROL VALVE 30

CONTROL VALVE 31

CONTROL VALVE 32

CONTROL VALVE 33

CONTROL VALVE 34

CONTROL VALVE 35