1111111.-8 NSW GOVERNMENT
Health
Certificate of Accreditation Sewage Management Facility
Septic Tanks & Collection Wells
This Certificate of Accreditation is issued by the Secretary of the NSW Ministry of Health pursuant to Clause 41(1) of the Local
Government (General) Regulation 2005.
Manufacturer: Graham's Precast Concrete Products Pty Ltd
Of: 4-8 Craig St, Kyogle, NSW, 2474
The Septic Tanks and Collection Wells as described in the following
Schedule have been accredited as sewage management facilities for use in single domestic premises in NSW.
A/Director, Environmental Health for Secretary (delegation PH335)
Issued: 18 December 2018 Certificate No: STCW013 Expires: 31 December 2020
-
The Certificate
Septic
Accreditation
vis tO 4 IF .111/0 NSW GOVERNMENT
of Accreditation
Tanks and
Hea
Collection
applies
Ith
Schedule
to the following
Wells
Model Description Size
Septic Tank Vertical axis type cylindrical pre-cast steel
fibre reinforced concrete with partition, lid,
access cover, inlet and outlet fittings.
Burial depth of the tank lid is restricted to 0
Mtn
2050
(without
partition)
2300L
3000 L
3100 L
5000 L
(with partition)
Collection Well Vertical axis type cylindrical pre-cast steel
fibre reinforced concrete.
Certification applies only to the construction
of the tank, lid and access cover. It does not
include the internal fittings or partitions.
Burial depth of the tank lid is restricted to 0
Mtn
2050 L
2300 L
3000 L
3350 L
5300 L
7000 L
-
65
GRAHAMS PRECAST--ONCREAMOD -
4-8 Craig St, Kyogle, NSW 2474
2050Lt Septic Tank Fibre Steel
Notes:
Tank: Construction of high density fibre
mesh, Concrete minimum
compressive strength of 35mpa at 28
days. Type A Cement.
Lid: F 41 reinforced, 35mpa fibre mesh
concrete. Inspection boxes. Rein
Plastics. Inverted lifting handles on
manhole.
Holes: Inlet and Outlet holes 110mm plastic
DIG HOLE = 2.00MTS WIDE
The bottom of the tank will be cast integrally with the tank
walls. It will be mortared at a later date before delivery.
TANK MARKINGS
* CAPACITY
* DATE
200mm
125mm
25mm
500mm
125mm
Tank Body
200 MM I I I 110 mm Outlet/Inlet
APPROVED
18 DEC 2018
NSW MINISTRY OF HEALTH
DOCUMENT NUMBER QPS 1 ISSUE NO: 1 DATE: 01/12/2016 PAGE NO: 33
-
25mm
* CAPACITY
*DATE 18 DEC 2018
NSW MINISTRY OF HEALTH
150MM 500MM
500 MM
2 X 280 MM
Bypass
480 MM
280 MM C
1 650 MM
40 MM Thick Concrete
1690 MM
a..s_ GRAHAMS PRECA CONCRETE PFRODUC
4-8 Craig St, Kyogle, NSW 2474
2300Lt Septic Tank Fibre Steel With Partition
Notes:
Tank: Construction of high density fibre
mesh, Concrete minimum
compressive strength of 35mpa at 28
days. Type A Cement
Lid: F 41 reinforced, 35mpa fibre mesh
concrete. Inspection boxes. Rein
500 mm Plastics. Inverted lifting handles on
manhole.
Holes: Inlet and Outlet holes 110mm plastic
fittings from Mt Barker Products.
Baffles: Mini baffle and partition baffle made
110 mm
DIG HOLE = 2.00MTS WIDE
TANK MARKIN S APPROVED 500mm
125mm 125mm
utl Water Level
1225 MM
65 MM
1700 MM
65 MM
1410 MM
1340 M
360 MM
110 MM Inlet 0 MM
Baffle Placemen
MM
380 MM
345 MM
1
Tank Body
110 mm Outlet/Inlet
1570
The bottom of the tank will be cast integrally with the tank
walls. It will be mortared at a later date before delivery.
65
1275 MM
1560 MM
200 MM
1465 MM
200mm
150MM
110 mm
-
DIG HOLE = 2.40MTS WIDE
200mm
125mm
25mm
APPROVED ii
TANK MARKINGS
* cAlDpin-4EC 2018
NSW' VIITNISTRY OF HEALTH
500mm
125mm
DOCUMENT NUMBER OPS 1 ISSUE NO: 1 PAGE NO: 35
DATE: 01/12/2016
150MM 500MM 150MM
110 mm Outlet/Inlet 200 MM
Tank Body
1835 MM
1460 MM
395 MM I —
/
110 MM Inlet 395 MM
Water Level
380 MM 500 MM
110 MM Outlet
— 330 MM
1625 MM Bypass
65MM
2 X 150MM 1120
1 65 MM 515 MM
1900 MM
45nim
2000 MM
1120 MM
4-8 Craig St, Kyogle, NSW 2474
3000Lt Septic Tank Fibre Steel With Partition
Notes:
Tank: Construction of high density fibre
mesh, Concrete minimum
compressive strength of 35mpa at 28
days. Type A Cement.
Lid: F 41 reinforced, 35mpa fibre mesh
110 mm concrete. Inspection boxes. Rein
500 mm Plastics. Inverted lifting handles on
manhole.
Holes: Inlet and Outlet holes 110mm plastic
fittings from Mt Barker Products.
Baffles: Mini baffle and partition baffle made
2000 mm
110 mm Baffle Placement
The bottom of the tank will be cast integrally with the tank walls. It will be mor-
tared at a later date before
-
DOCUMENT NUMBER QPS 1 ISSUE NO: 1
PAGE NO: 36
DATE: 01/12/2016
5000Lt Septic Tank Fibre Steel With Partition
Notes:
Tank: Construction of high density fibre
mesh, Concrete minimum
compressive strength of 35mpa at
28
days. Type A Cement.
Lid: F 41 reinforced, 35mpa fibre mesh
concrete. Inspection boxes. Rein
Plastics. Inverted lifting handles on
00mm 500mm
125mm
60 MM 5mm
150MM 500MM 150MM
75MM
1480 MM 200 MM
405 MM —
/
530 MM 110 MM net
5o mm Water Level
380 MM 500 MM
10 MM Outlet
330 MM
2X 150MM 1150
125mm
Tank Body
110 mm Outlet/Inlet
NAM 1025 MM 1700 MM Bypass
1 20 MM
2430 MM
1555 MM
70 MM
2550 MM
4-8 Craig St, Kyogle, NSW 2474
* CAPACITY
* DATE
[1.1 >
TANK MARKING 0
I X
I <
The bottom of the tank will
be cast integrally with the
tank walls. It will be mor-
tared at a later date before
MM
1
150 MM
MM
40 MM Thick Concrete
-
IP* ammkt GRAHAMS PFRECA11111% 7Pir. • CONCRETE PROD TS
ISSUE NO 1 DATE: 01/12/2016 DOCUMENT NUMBER QPS 1 PAGE NO 37
4-8 Craig St, Kyogle, NSW 2474
7000Lt Septic Tank Fibre Steel
2550 MM
TANK MARKINGS
* CAPACITY
* DATE
days. Type A Cement.
Lid: F 41 reinforced, 35mpa fibre mesh
concrete. Inspection boxes. Rein
Plastics. Inverted lifting handles on
DIG HOLE = 2 40MTS WIDE
APPROVED
18 DEC 2018
NSW MINISTRY OF HEALTH
The bottom of the tank will be cast integrally with the tank walls. It will be mor-
tared at a later date before
1650 MM 2075 MM
50 MM
75MM
INLET 350 MM
Water Level
2 DO MM 930 MM
2450 MM
70 MM
2550 MM
Notes:
Tank: Construction of high density fibre
mesh, Concrete minimum
compressive strength of 35mpa at 28
-
65
65
275 mm
65
Tank Body
200 MM I I I 110 mm Outlet/Inlet
we GRAHAMS PRECASTillik iqpip CONCRETE PRO UCTSUIV 4-8 Craig St, Kyogle, NSW 2474
2050Lt Collection Well
Notes:
Tank: Construction of high density fibre
mesh, Concrete minimum
compressive strength of 35mpa at 28
days. Type A Cement.
Lid: F 41 reinforced, 35mpa fibre mesh
concrete. Inspection boxes. Rein
Plastics. Inverted lifting handles on
manhole.
Holes: Inlet and Outlet holes 110mm plastic
fittings from Mt Barker Products.
DIG HOLE = 2.00MTS WIDE
The bottom of the tank will be cast integrally with the tank
walls. It will be mortared at a later date before delivery.
TANK MARKINGS
* CAPACITY
* DATE
200mm
M125mm
25mm
500mm
125mm
APPROVED
18 DEC 2018
NSW MINISTRY OF HEALTH
DOCUMENT NUMBER QPS 1 ISSUE NO: 1 DATE :01/12/2016 PAGE NO: 36
-
200 MM 10 mm Outlet/Inlet
65 MM
1700 MM
55MM
4-8 Craig St, Kyogle, NSW 2474
2300Lt Collection Well
Notes:
Tank: Construction of high density fibre
mesh, Concrete minimum
compressive strength of 35mpa at 28
days. Type A Cement.
Lid: F 41 reinforced, 35mpa fibre mesh
concrete. Inspection boxes. Rein
Plastics. Inverted lifting handles on
manhole.
Holes: Inlet and Outlet holes 110mm plastic
DIG HOLE = 2 00MTS WIDE
The bottom of the tank will be cast integrally with the tank
walls. It will be mortared at a later date before delivery.
TANK MARKINGS
*CAPACITY
* DATE
200mm
M125mm
25mm
500mm
125mm
65
110 MM
150MM 500MM 150MM
345 MM 110 MM Inlet
500 MM Water Level
••.•.• 380 MM
360 MM
1570
APPROVED
1340 M 1 8 DEC 2018
NSW MINISTRY OF HEALTH
r- 1560 MM 1690 MM
DOCUMENT NUMBER CPS 1 ISSUE NO: 1 DATE: 01/12/2016 PAGE NO: 39
1225 MM
1275 MM
-
TANK MARKINGS
* CAPACITY
* DATE
DIG HOLE = 2 40MTS WIDE
200mm
\\_17 125mm
25mm
500mm
125mm
DOCUMENT NUMBER OPS 1 PAGE NO: 40
ISSUE NO: 1 DATE: 01/12/2016
150MM 500MM 150MM
200 MM I I I 1 110 mm Outlet/Inlet
Tank Body
1 395 MM
110 MM Inlet
1 5o mm
380 MM
1120 MM
Water Level
500 MM
APPROVED
18 DEC 2018
NSW MINISTRY OF HEALTH
1625 MM
1460 MM f
1
I I
110 MM Outlet
65MM
' 330 MM
1120 MM
515 MM
1900 MM
45mm
2000 MM
GRAHAMS P RETE =MI
R1Y
4-8 Craig St, Kyogle, NSW 2474
3000Lt Collection Well
Notes:
Tank: Construction of high density fibre
mesh, Concrete minimum
compressive strength of 35mpa at 28
days. Type A Cement.
Lid: F 41 reinforced, 35mpa fibre mesh
concrete. Inspection boxes. Reln
Plastics. Inverted lifting handles on
manhole.
Holes: Inlet and Outlet holes 110mm plastic
fittings from Mt Barker Products.
The bottom of the tank will be cast integrally with the tank walls. It will be mor-
tared at a later date before
-
DOCUMENT NUMBER QPS 1 PAGE NO: 41
ISSUE NO: 1 DATE: 01/12/2016
150MM 500MM 150MM
395 MM 110 MM Inlet
Water Level ned
..... 380 MM
Tank Body
200 MM I I I 110 mm Outlet/Inlet
APPROVED
1 B DEC 2018
NSW MINISTRY OF HEALTH
1460 MM
110 MM Outlet
330 MM
I
500 MM
Bypass
65MM
— 2 X 150MM 1120 MIN
1 65 MM
515 MM
1900 MM
5mm
2000 MM
112 MM
4-8 Craig St, Kyogle, NSW 2474
3300Lt Collection Well
Notes:
Tank: Construction of high density fibre
mesh, Concrete minimum
compressive strength of 35mpa at 28
days. Type A Cement.
Lid: F 41 reinforced, 35mpa fibre mesh
concrete. Inspection boxes. ReIn
Plastics. Inverted lifting handles on
manhole.
Holes: Inlet and Outlet holes 110mm plastic
fittings from Mt Barker Products.
DIG HOLE = 2.40MTS WIDE
The bottom of the tank will be cast integrally with the tank walls. It will be mor-
tared at a later date before delivery.
TANK MARKINGS
* CAPACITY
* DATE
200mm
M125mm
25mm
500mm
125mm
-
DIG HOLE = 2.40MTS WIDE
1 55MTS
200mm
125mm
500mm
125mm
25mm
Tank Body
200 MM R 110 mm Outlet/Inlet
GRAHAMS PRECA CONCRETE PRO
4-8 Craig St, Kyogle, NSW 2474
5000Lt Collection Well Notes:
Tank: Construction of high density fibre
mesh, Concrete minimum
compressive strength of 35mpa at 28
days. Type A Cement.
Lid: F 41 reinforced, 35mpa fibre mesh
concrete. Inspection boxes. Reln
Plastics. Inverted lifting handles on
manhole.
Holes: Inlet and Outlet holes 110mm plastic
TANK MARKINGS
* CAPACITY
* DATE
* NAME
60 MM
150MM 500MM 150MM
I I I I
a MM Outlet
1480 MM
405 MM I
Water Level '50 klm
380 MM
30 MM
1150 MM APPROVED
18 DEC 2018
NSW MINISTRY OF HEALTH
2430 MM
70 MM
2550 MM
DOCUMENT NUMBER QPS 1 ISSUE NO :1 DATE: 01/12/2016 PAGE NO: 42
102 MM 17 MM
1220 MM
555 MM
The bottom of the tan be cast integrally with the tank walls. It will be mor-
tared at a later date before delivery.
10 MM Inlet 530 MM
500 MM
75MM
-
500mm
DOCUMENT NUMBER QPS 1 PAGE NO: 43
ISSUE NO: 1 DATE: 01/12/2016
200mm
125mm
200 MI4?5mni
Tank Body
110 mm Outlet/Inlet
APPROVED
18 DEC 2018
NSW MINISTRY OF HEALTH
I I 75MM
1480 MM
405 MM I —
380 MM
110 MM Inlet
50 MM
530 MM
VVater Levei
500 MM
110 MM Outlet
330 MM
1700 MM
150MM 500MM 150MM
1150 NW
1 20 MM 1555 MM
2430 MM
70 MM
2550 MM
60 MM
1025 MM
4-8 Craig St, Kyogle, NSW 2474
The bottom of the tank will be cast integrally with the tank walls. It will be mor-
tared at a later date before
5300Lt Collection Well Notes:
Tank: Construction of high density fibre
mesh, Concrete minimum
compressive strength of 35mpa at 28
days. Type A Cement.
Lid: F 41 reinforced, 35mpa fibre mesh
concrete. Inspection boxes. Rein
Plastics. Inverted lifting handles on
manhole.
Holes: Inlet and Outlet holes 110mm plastic
fittings from Mt Barker Products.
TANK MARKINGS
* CAPACITY
* DATE
DIG HOLE = 2.40MTS WIDE
1 55MTS DEEP
-
IP* 4-8 Craig St, Kyogle, NSW 2474
7000Lt Collection Well Notes:
Tank: Construction of high density fibre
mesh, Concrete minimum
compressive strength of 35mpa at 28
days. Type A Cement.
Lid: F 41 reinforced, 35mpa fibre mesh
concrete. Inspection boxes. Rein 2550 MM
Plastics. Inverted lifting handles on
manhole.
Holes: Inlet and Outlet holes 110mm plastic
fittings from Mt Barker Products.
The bottom of the tank will be cast integrally with the tank walls. It will be mor-
tared at a later date before
TANK MARKINGS
* CAPACITY
* DATE
DIG HOLE = 2.40MTS WIDE
50 MM
75M M
INLET 350 MM
Water Level1.
1650 MM 2075 MM
2 COMM 930 MM
2450 MM
70 MM
2550 MM
.n.o....••••••••••.1.11111.1111.0•41
APPROVED
18 DEC 2018
NSW MINISTRY OF HEALTH
DOCUMENT NUMBER QPS 1 ISSUE NO: 1 DATE; 01/12/2016
PAGE NO: 44