ZXG10 iTC Product Description
ZXG10 iTC Product Description
ZXG10 iTC Product Description
Version Date Author Approved By Remarks
V8.00 2008-02-12GSM&PCS Planning and System Dept.
Not open to the Third Party
V8.01 2010-02-05GSM&PCS Planning and System Dept.
Not open to the Third Party
ZTE Confidential Proprietary © 2010 ZTE Corporation. All rights reserved. I
© 2010 ZTE Corporation. All rights reserved.
ZTE CONFIDENTIAL: This document contains proprietary information of ZTE and is not to be disclosed or used without the prior written permission of ZTE.
Due to update and improvement of ZTE products and technologies, information in this document is subjected to change without notice.
ZXG10 iTC Product Description
TABLE OF CONTENTS
1 General Description..................................................................................................11.1 ZTE GSM BSS Family Introduction.............................................................................1
2 Highlights and Main Features..................................................................................22.1 Highlights.................................................................................................................... 22.1.1 All IP Hardware Platform.............................................................................................22.1.2 High Capacity.............................................................................................................22.1.3 Modularized Design....................................................................................................22.1.4 Flexible Access...........................................................................................................22.1.5 Universal Platform.......................................................................................................22.2 Advanced Features.....................................................................................................22.2.1 TC resource shared by multi-BSC..............................................................................22.2.2 Whole network sharing, dynamic distribution of TC resource.....................................32.2.3 1:8 Multiplexing of Ater interface at HR.......................................................................32.2.4 Flexible A.................................................................................................................... 32.2.5 Gb multiplexed in Ater interface..................................................................................32.2.6 TFO............................................................................................................................. 3
3 ZXG10 iTC System Structure....................................................................................43.1 Equipment Overview...................................................................................................43.2 Hardware Structure.....................................................................................................43.3 Software Structure......................................................................................................5
4 ZXG10 iTC Configuration..........................................................................................74.1 Typical Configuration for TC Pool in One rack............................................................74.2 Typical Configuration for TC Pool in Four racks.........................................................74.3 Typical Configuration for Far TC in One rack..............................................................84.4 Typical Configuration for Far TC in Four racks...........................................................9
5 Technical Specification...........................................................................................105.1 Mechanical Dimensions............................................................................................105.2 Weight....................................................................................................................... 105.3 Color......................................................................................................................... 105.4 Power Requirements................................................................................................115.4.1 Overview...................................................................................................................115.4.2 PWRD....................................................................................................................... 115.5 Power Consumption..................................................................................................115.6 Electromagnetic Compatibility(EMC)........................................................................125.7 Environment Requirements......................................................................................135.7.1 Working Environment................................................................................................135.7.2 Storage Environment................................................................................................135.7.3 Transportation...........................................................................................................135.7.4 Anti-Earthquake Level...............................................................................................135.7.5 Noise Level...............................................................................................................135.8 Performance Index....................................................................................................145.9 Others....................................................................................................................... 155.9.1 Redundancy..............................................................................................................155.9.2 Reliability..................................................................................................................15
6 System Interface......................................................................................................166.1 Overview...................................................................................................................166.2 A Interface................................................................................................................166.3 Ater Interface............................................................................................................17
II © 2010 ZTE Corporation. All rights reserved. ZTE Confidential Proprietary
ZXG10 iTC Product Description
7 Abbreviations..........................................................................................................18
FIGURES
Figure 1 Outlook of ZXG10 iTC...................................................................................................1Figure 2 ZXG10 iTC Hardware Structure....................................................................................4Figure 3 ZXG10 iTC Software Structure.....................................................................................5Figure 4 One rack configuration of ZXG10 iTC for TC Pool........................................................7Figure 5 Four rack configuration of ZXG10 iTC for TC Pool.......................................................8Figure 6 One rack configuration of ZXG10 iTC for Far TC..........................................................8Figure 7 Three rack configuration of ZXG10 iTC for Far TC.......................................................9Figure 8 External View of ZXG iTC...........................................................................................10Figure 9 External interfaces of ZXG10-iTC...............................................................................16
TABLES
Table 1 Power consumption of ZXG10 iTC..............................................................................11Table 2 Conducted emission suppression of the power port...................................................12Table 3 Whole-system radiated emission suppression............................................................12Table 4 Main performance index of ZXG10 iTC for TC Pool....................................................14Table 5 Abbreviation List.........................................................................................................18
ZTE Confidential Proprietary © 2010 ZTE Corporation. All rights reserved. III
ZXG10 iTC Product Description
FIGURES
Figure 1 Outlook of ZXG10 iTC...................................................................................................1Figure 2 ZXG10 iTC Hardware Structure....................................................................................4Figure 3 ZXG10 iTC Software Structure.....................................................................................5Figure 4 One rack configuration of ZXG10 iTC for TC Pool........................................................7Figure 5 Four rack configuration of ZXG10 iTC for TC Pool.......................................................8Figure 6 One rack configuration of ZXG10 iTC for Far TC..........................................................8Figure 7 Three rack configuration of ZXG10 iTC for Far TC.......................................................9Figure 8 External View of ZXG iTC...........................................................................................10Figure 9 External interfaces of ZXG10-iTC...............................................................................15
TABLES
Table 1 Power consumption of ZXG10 iTC..............................................................................11Table 2 Conducted emission suppression of the power port...................................................11Table 3 Whole-system radiated emission suppression............................................................12Table 4 Main performance index of ZXG10 iTC for TC Pool....................................................13
IV © 2010 ZTE Corporation. All rights reserved. ZTE Confidential Proprietary
ZXG10 iTC Product Description
1 General Description
1.1 ZTE GSM BSS Family Introduction
ZTE GSM BSS family inherits the idea of 3G constructions, designing in all IP hardware
structure, modularized and distributed idea.
ZXG10 iTC is designed especially for high-speed integrated network. All IP hardware
structure, high integration and intelligent design are satisfied with mixed network
management and flat network requirement.
As a powerful TC network element, ZXG10 iTC can be configured as remote TC or TC
Pool (TransCoder Pool). Aggregations of TC channels which support all coding types to
implement dynamically distributed for TC resource in pool within entire network and
realize resource sharing.
Figure 1 Outlook of ZXG10 iTC
ZTE Confidential Proprietary © 2010 ZTE Corporation. All rights reserved. 1
ZXG10 iTC Product Description
2 Highlights and Main Features
2.1 Highlights
2.1.1 All IP Hardware Platform
ZXG10 iTC uses the same all-IP hardware platform as ZXG10 iBSC. The hardware
platform based on all-IP can easily realize TFO/TrFO functions, IP Ater and IP A
interface for all-IP evolution.
2.1.2 High Capacity
ZXG10 iTC used as TC pool, fully configured with 4 racks supports 68040 traffic
channels in Max.; and used as Far TC, supports 3072TRX with 100%HR. By high
integration and capacity design, equipment dimension is obviously reduced, and power
consumption is also decreased greatly.
2.1.3 Modularized Design
ZXG10 iTC can be flexible configured for modularized design. For different requirement
of capacity, ZXG10 iTC can be configured with dual-shelf, single rack to 4 racks for
convenient capacity expansion in future.
2.1.4 Flexible Access
ZXG10 iTC supports various access standards including E1/T1, STM-1, and FE.
Transmission solution can also be replaced with Microwave, WIMAX, BWA, satellite.
2.1.5 Universal Platform
The All-IP hardware is universal for ZXWN NE, ZXG10 iBSC, ZXWN RNC (WCDMA)
and ZXTR RNC (TD-SCDMA). ZXG10 iTC can be integrated with iBSC co-rack.
2.2 Advanced Features
2.2.1 TC resource shared by multi-BSC
One iTC can support multi-iBSC (up to 16 BSCs) which shares all TC resource.
2 © 2010 ZTE Corporation. All rights reserved. ZTE Confidential Proprietary
ZXG10 iTC Product Description
2.2.2 Whole network sharing, dynamic distribution of TC resource
iTC system supports whole network sharing for TC resource in all resource shelves. iTC
system can also distribute TC resource dynamically without binding with A interface TS.
Operators can calculate TC capacity by actual traffic requirement rather than distribute
TC resource by semi-permanent connections. Dynamic distribution of TC resource can
reduce 30% resource investment.
2.2.3 1:8 Multiplexing of Ater interface at HR
Ater interface supports 1:8 multiplexing at half rate.
2.2.4 Flexible A
Flexible A supports Disaster Tolerance of MSC (up to 16 MSCs).
2.2.5 Gb multiplexed in Ater interface
Gb data dynamic multiplexed in Ater interface increases utilization ratio of Ater interface
link, saving Gb links resource and decreasing operators’ transmission construction and
lease cost.
Gb data dynamic multiplexed in Ater interface can realize convergence of packet data
and voice data to save link resources.
2.2.6 TFO
TFO ( Tandem Free Operation ) is accomplished after call setting up by in-band
negotiation of two TC to its CODEC. TFO avoids unnecessary voice CODEC
conversion between transmitter and receiver among mobile subscribers to improve the
voice quality.
ZTE Confidential Proprietary © 2010 ZTE Corporation. All rights reserved. 3
ZXG10 iTC Product Description
3 ZXG10 iTC System Structure
3.1 Equipment Overview
ZXG10 iTC is hardware platform based on the same 3G platform as ZXG10 iBSC.
According to the requirement of design, iTC can support various interfaces such as E1
(TDM or IPoverE1), STM-1, FE and is also compatible with SIGTRAN. ZXG10 iTC
System is based on IP switch..
3.2 Hardware Structure
Figure 2 ZXG10 iTC Hardware
Structure
ZXG10 iTC hardware structure consists of the following 5 units:
O&M Unit
O&M Unit controls entire system, supports processing of control protocols/signals and
implements the operation and maintenance function.
Ater Interface Access Unit: FSMU
4 © 2010 ZTE Corporation. All rights reserved. ZTE Confidential Proprietary
ZXG10 iTC Product Description
FSMU offers physical interfaces including Ater E1 、 STM-1 、 FE and their protocol
processing.
IP Switch Unit
FSMU and TC resource are connected by IP switch..
TC Resource Pool
TC Resource Pool is used to realize conversion and rate adaptation between voice code
(such as Enhanced Full rate, Full rate, Half rate, AMR andAMR HR etc.) and PCM 64K
code.
A Interface Unit: AIU
A interface currently mainly uses E1/STM-1, IP-borne signaling to realize SIGTRAN.
3.3 Software Structure
ZXG10 iTC software structure is complicated, supporting multi-BSC access and dynamic
distribution of TC resource. Software structure mainly includes BSP&DRIVERS, OSS,
BRS, PP, SCS, DBS, OMS, SS,TCC,TCSS and TCU.
Figure 3 ZXG10 iTC Software
Structure BSP&Driver: BSP sub-system offers driver for hardware, screen hardware function
and mapping of logical functions to upper software.
ZTE Confidential Proprietary © 2010 ZTE Corporation. All rights reserved. 5
ZXG10 iTC Product Description
OSS: Operation Supporting System, which works between BSP and other sub-
system. Task of OSS includes process communication, file management,
equipment driving, schedule work, etc.
BRS: Bearer Sub-system works based on OSS to offer ATM, IP, TDM bearer
services for service sub-system, signaling sub-system, O&M sub-system. The
function of BRS can be divided as link layer function, network transmission function,
dynamic router function, ATM function, flux-controlling function.
PP: Primary Peripheral sub-system. PP sub-system mainly has five functions: digital
interface management, switch network management, offering system clock,
monitoring environment and power management.
SCS: System Control sub-system, works on OSS and Database sub-system,
responsible for monitoring whole system, downloading software and upgrading
system.
DBS: Database Sub-system, which works on OSS sub-system, responsible for
management of network element and information of services, signaling, protocol.
OMS: Operation and Maintenance Sub-system, which works on DBS and OSS,
manages network elements including BTS and BSC.
SS: Signaling Sub-system, which work on OSS,DBS,BRS, deals with narrow band
No.7 signaling, WB No.7 signaling, calling signaling, IP signaling and network gate
control signaling.
TCC : TC Control, manages the control panel protocol of Ater A including TC
resource distribution, A interface circuit checking and occupying, Ater interface
circuit application and distribution, controlling accomplishment of connection
process.
TCU:TC User parts in iTC includes conversion among TCU frame data and inner
Ethernet data.
TCSS :TC Support Sub-system. TCSS supports control panel and user panel to
fulfill whole iTC functions including signaling trace, load control, access control, TC
resource distribution, performance measurement etc.
6 © 2010 ZTE Corporation. All rights reserved. ZTE Confidential Proprietary
ZXG10 iTC Product Description
4 ZXG10 iTC Configuration
ZXG10 iTC has modularized design and distributed management system. Configuration
of iTC is so flexible and has high integration and big capacity; only four racks of ZXG iTC
can support up to 68040 TCHs.
For different functional units, ZXG10 iTC designs corresponding shelves, which are:
BPSN, BUSN, BCSN.
Four typical types of iTC configuration is shown below.
4.1 Typical Configuration for TC Pool in One rack
Application scene: in moderate capacity (0-7560TCH)
Capacity: 7560TCH
Ater: 64E1/1STM-1(1+1 standby)
A interface: 256E1/4 STM-1(1+1 standby)
ZTE Confidential Proprietary © 2010 ZTE Corporation. All rights reserved. 7
ZXG10 iTC Product Description
Figure 4 One rack configuration of
ZXG10 iTC for TC Pool
4.2 Typical Configuration for TC Pool in Four racks
Application scene: in huge capacity (up to 68040TCH)
Capacity: 68040TCH
Ater: 448E1/7STM-1(1+1 standby)
A interface: 2176E1/34 STM-1(1+1 standby)
Figure 5 Four rack configuration of
ZXG10 iTC for TC Pool
4.3 Typical Configuration for Far TC in One rack
Application scene: in moderate capacity (0-8400TCH)
Capacity: 8400TCH
Ater: 64E1/1STM-1(1+1 standby)
A interface: 256E1/4 STM-1(1+1 standby)
8 © 2010 ZTE Corporation. All rights reserved. ZTE Confidential Proprietary
ZXG10 iTC Product Description
Figure 6 One rack configuration of
ZXG10 iTC for Far TC
4.4 Typical Configuration for Far TC in Four racks
Application scene: in huge capacity (up to 48720TCH, 3072TRX with 100% HR)
Capacity: 48720TCH, 3072TRX with 100% HR
Ater: 320E1/5STM-1(1+1 standby)
A interface: 1536E1/24 STM-1(1+1 standby)
ZTE Confidential Proprietary © 2010 ZTE Corporation. All rights reserved. 9
ZXG10 iTC Product Description
Figure 7 Three rack configuration of
ZXG10 iTC for Far TC
10 © 2010 ZTE Corporation. All rights reserved. ZTE Confidential Proprietary
ZXG10 iTC Product Description
5 Technical Specification
5.1 Mechanical Dimensions
Figure 8 External View of ZXG iTC
Rack dimensions: 2000mm (H)×800mm (D)×600mm (W)
5.2 Weight
The weight of full configuration rack is less than 350Kg.
5.3 Color
Rack Color: Navy Blue
ZTE Confidential Proprietary © 2010 ZTE Corporation. All rights reserved. 11
ZXG10 iTC Product Description
Front Panel Color: Black
5.4 Power Requirements
5.4.1 Overview
Requirement for the primary DC by ZXG10 iTC:
The nominal value of voltage provided by the power equipment in the equipment room is
-48V, with an acceptable range from -57V to -40V.
The noise level in the power voltage should be in compliance with the general technical
specifications of the former MPT.
Power supply has over-current protection and indication.
Grounding resistance: <1 ohm.
5.4.2 PWRD
PWRD is located on top of the rack, and it serves mainly to connect the primary power
supply into the rack, distribute power to the rack, and directly supply power to the
scavenger fans. It is capable of providing over/under -48V alarm and anti-lightening
protection.
5.5 Power Consumption
The power consumption of each machine frame with maximum configuration is shown
below:
Table 1 Power consumption of ZXG10 iTC
No. Machine Frame Name Power Consumption (W)
1 BPSN 450W
2 BUSN 800W
3 BCSN 260W
4 Fan (one rack) 200W
The power consumption of ZXG10 iTC rack is based on the calculation according to the
actual configuration.
12 © 2010 ZTE Corporation. All rights reserved. ZTE Confidential Proprietary
ZXG10 iTC Product Description
5.6 Electromagnetic Compatibility(EMC)
Anti-static capability.
In compliance with Detailed Rules for Network-Access Detection of Mobile Switches, i.e.,
the anti-static capability satisfies the following specifications:
Contact discharging: ±6kV; air discharging: ±8kV.
In full-load working (i.e., ZXG10 iBSC rack is configured to full capacity), the conducted
emission on the power cable conforms to the level-A standard of GB9254-1998, as
shown in Table 2.
Table 2 Conducted emission suppression of the power port
Frequency range Quasi-peak detector Average detector
0.15kHz~500kHz 79 dBuV 66 dBuV
500kHz~30MHz 73 dBuV 60 dBuV
Whole-system radiated emission suppression
In full-load working (i.e., ZXG10 iBSC rack is configured to full capacity), the radiated
emission on the whole system conforms to the level-B standard of GB9254-1998, as
shown in Table 3.
Table 3 Whole-system radiated emission suppression
Frequency range Limits of value (quasi-peak detector)
30MHz~230MHz 30 dBuV/m
230MHz~1000MHz 37 dBuV/m
Whole-system anti-radiation interference
IEC1000-4-3, level 2, 3V/m.
Anti-lightning interference of A/Abis/Gb interface
IEC1000-4-5, level 2, ±500V.
Anti-pulse series interference
ZTE Confidential Proprietary © 2010 ZTE Corporation. All rights reserved. 13
ZXG10 iTC Product Description
The anti-burst interference of the power port. IEC1000-4-4, level 2, ±1kV.
The anti-burst interference of the A/Abis/Gb interface. IEC1000-4-4, level 2, ±500V.
Anti-RF conduction interference
The anti-RF conduction interference of the power port. IEC1000-4-6, level 2, ±3V.
The anti-RF conduction interference of the A/Abis/Gb port. IEC1000-4-6, level 2, ±3V.
5.7 Environment Requirements
5.7.1 Working Environment
1 1. Working temperature
Long-term working temperature: 0°C~40°C.
Short-term working temperature: -5°C~45°C
2 2. Relative humidity
Long-term work relative humidity: 20%~90%.
Short-term work relative humidity: 5%~95%.
5.7.2 Storage Environment
It should be packed and stored indoors.
Temperature: -45°C~70°C
Relative humidity: 10%~90%
5.7.3 Transportation
Load 2K4P/2B2/2C3/2S3/2M3,time of transportation should not exceed 30 days.
5.7.4 Anti-Earthquake Level
For the anti-earthquake level, ZXG10 iTC can withstand Dietmar-Lee 8 levels of
earthquake damage.
5.7.5 Noise Level
Less than 60dB.
14 © 2010 ZTE Corporation. All rights reserved. ZTE Confidential Proprietary
ZXG10 iTC Product Description
5.8 Performance Index
The performance index of ZXG10 iTC is shown in Table 4 and 5.
Table 4 Main performance index of ZXG10 iTC for TC Pool
Capacity Maximum capacity 68040TCH
InterfaceAter interface 448E1/7STM-1(1+1 standby)
A interface 2176E1/34 STM-1(1+1 standby)
functions
AMR Supports
TFO Supports
MSC No. in Flex A 16
BSC No. in Flex Ater 16
PerformanceMTBF value ≥100,000 hours
System restart time <10 minutes
Clocking3rd Level
Support: BITS, Line 8k, GPS
Table 5 main performance index of ZXG10 iTC for Far TC
Capacity Maximum capacity 48720TCH
InterfaceAter interface 320E1/5STM-1(1+1 standby)
A interface 1536E1/24 STM-1(1+1 standby)
functions
AMR Supports
TFO Supports
MSC No. in Flex A 16
BSC No. in Flex Ater 16
PerformanceMTBF value ≥100,000 hours
System restart time <10 minutes
Clocking3rd Level
Support: BITS, Line 8k, GPS
ZTE Confidential Proprietary © 2010 ZTE Corporation. All rights reserved. 15
ZXG10 iTC Product Description
5.9 Others
5.9.1 Redundancy
The modularized design ensures the whole system with high stable performance, and
failure of one module will not cause service interruption.
Furthermore, ZXG10 iTC has taken chipset and components reliability into
consideration, for the key modules ZXG10 iTC uses 1+1 backup and TC resource load
division to maintain the system availability
5.9.2 Reliability
In ZXG10 iTC, the algorithm of system reliability is based on the national military
GJB/Z299B Electronic Equipment Reliability Estimation Manual and US military
handbook MIL-HDBK-217F Electronic Equipment Reliability Estimation.
Under detail calculation and proven by strict environment tests, ZXG10 iTC can ensure
reliability of MTBF is more than 100,000 hours and MTTR is less than 0.5 hour.
16 © 2010 ZTE Corporation. All rights reserved. ZTE Confidential Proprietary
ZXG10 iTC Product Description
6 System Interface
6.1 Overview
The external interfaces of the ZXG10 iTC are shown in Follow
Figure 9 External interfaces of
ZXG10-iTC
In GSM system, TC POOL is mainly equipped with the following physical interfaces:
A interface connected to the MSC;
Ater interface connected to BSC;
SMIPS fore/back ground interface connected to OMM;
6.2 A Interface
A interface is the interface between BSC and MSS/CN, that is between TC and
MSS/CN.
ZTE Confidential Proprietary © 2010 ZTE Corporation. All rights reserved. 17
ZXG10 iTC Product Description
ZXG10 iTC supports E1/T1, STM-1 for A interface.
6.3 Ater Interface
Ater interface is system internal interface between iBSC and TC.
ZXG10 iTC supports E1/T1, STM-1, FE for Ater interface.
18 © 2010 ZTE Corporation. All rights reserved. ZTE Confidential Proprietary
ZXG10 iTC Product Description
7 Abbreviations
Table 5 Abbreviation List
Abbreviations Full names
AIU A Interface UnitA
BCSN Backplane of Circuit Switch Network
BCTC Backplane of ConTrol Center
BPSN Backplane of Packet Switch Network
BRS Barer Sub-system
BSC Base Station Controller
BSS Base Station System
BTS Base Transceiver Station
BUSN Backplane of Universal Switch Network
CMP Service Main Processor
DBS Database Sub-system
DTB Digital Trunk Board
EMC Electro-Magnetic Compatibility
FSMU Far Sub-Multiplexing Unit
MP Main Processor
MSC Mobile services Switching Center
OMC Operation and Maintenance Center
OMP Operation Main Processor
OMS Operating Maintenance Subsystem
OSS Operating & Support Subsystem
PWRD POWeR Distributor
PP Primary Peripheral
PRCBU Pool Resources board Configuration Basal Unit iTC
QoS Quality of Service
SCM System Control Module
SCS System Control Sub-system
SCU System Control Unit
SPB Signaling Process Board
SMIPS Small Interactive Image Processing System
SS Signaling Sub-system
TC TransCoder
TCU TransCoder Unit
ZTE Confidential Proprietary © 2010 ZTE Corporation. All rights reserved. 19
ZXG10 iTC Product Description
TFO Tandem Free Operaton
UIM Universal Interface Module
20 © 2010 ZTE Corporation. All rights reserved. ZTE Confidential Proprietary