11 (Brodski i Offshor Kablovi)

38
Katalog Catalogue 06 03 1 03 2 F Shipboard and offshore cables Brodski i offshore kabeli

description

katalog

Transcript of 11 (Brodski i Offshor Kablovi)

Page 1: 11 (Brodski i Offshor Kablovi)

KatalogCatalogue

06 03 1 032F

Shipboardand offshorecables

Brodski ioffshorekabeli

Page 2: 11 (Brodski i Offshor Kablovi)

1. GENERAL

2. CODE DESIGNATION

3. CABLE TYPES

3.1 BXO-HFTG

3.2 BXOZO-HFTG

3.4 BXHOZO-HFTG

3.5 TBXOZO-HFTG

3.6 TBX(Z1)OZO-HFTG

3.7 TBX(Z)OZO-HFTG

3.8 BXO-HFVO

3.9 BXOZO-HFVO

3.10 TBXOZO-HFVO

3.11 TBX(Z1)OZO-HFVO

3.12 TBX(Z)OZO-HFVO

4. TESTS

5. TECHNICAL DATA

Unarmoured fire retardant cable 0,6/1 kV

Armoured, fire retardant cable 0,6/1 kV

Armoured, medium voltage, fire retar-

dant cable for 3,6/6 kV and 6/10 kV

Telecommunication armoured, fire retar-

dant cable 60 V, 250 V and 0,6/1 kV

Telecommunication, armoured, common

screen, fire retardant cable 60 V, 250 V

and 0,6/1 kV

Telecommunication, armoured, individual

and common screen, fire retardant cable

60 V, 250 V and 0,6/1 kV

Unarmoured, fire resistant cable 0,6/1 kV

Armoured, fire resistant cable 0,6/1 kV

Telecommunication, armoured, fire resistant

cable 60 V, 250 V and 0,6/1 kV

Telecommunication, armoured, common

screen, fire resistant cable 60 V,

250 V and 0,6/1 kV

Telecommunication, armoured, individual

and common screen, fire resistant cable

60 V, 250 V and 0,6/1 kV

3. BXOZO-HFTG3 EMCArmoured, fire retardant cable 0,6/1 kV

1. OP]ENITO

2. KODNA OZNAKA

3. TIPOVI KABELA3.1 BXO-HFTG

3.2 BXOZO-HFTG

3.4 BXHOZO-HFTG

3.5 TBXOZO-HFTG

3.6 TBX(Z1)OZO-HFTG

3.7 TBX(Z)OZO-HFTG

3.8 BXO-HFVO

3.9 BXOZO-HFVO

3.10 TBXOZO-HFVO

3.11 TBX(Z1)OZO-HFVO

3.12 TBX(Z)OZO-HFVO

4. ISPITIVANJA

5. TEHNI^KI PODACI

Nearmirani, te{ko gorivi kabel 0,6/1 kV

Armirani, te{ko gorivi kabel 0,6/1 kV

Armirani, srednje-naponski, te{kogorivikabel za 3,6/6 kV i 6/10 kV

Telekomunikacijski, armirani, te{kogorivi kabel 60 V, 250 V i 0,6/1 kV

Telekomunikacijski, armirani, te{kogorivikabel sa zajedni~kim ekranom60 V, 250 V i 0,6/1 kV

Telekomunikacijski, armirani, te{kogorivikabel s individualnim i zajedni~kimekranom 60 V, 250 V i 0,6/1 kV

Nearmirani, vatrootporni kabel 0,6/1 kV

Armirani, vatrootporni kabel 0,6/1 kV

Telekomunikacijski, armirani, vatrootpornikabel 60 V, 250 V i 0,6/1 kV

Telekomunikacijski, armirani, vatrootpornikabel sa zajedni~kim ekranom60 V, 250 V i 0,6/1 kV

Telekomunikacijski, armirani, vatrootpornikabel s individualnim i zajedni~kimekranom 60 V, 250 V i 0,6/1 kV

3. BXOZO-HFTG3 EMCArmirani, te{ko gorivi kabel 0,6/1 kV

stranica: page:

1

1

2

5

10

13

14

17

20

23

26

27

30

33

34

1

1

2

5

10

13

14

17

20

23

26

27

30

33

34

TVORNICA ELEKTRI^NIH KABELA ELECTRIC CABLE WORKS

Brodski i offshore kabeli Shipboard and offshore cables

SADR@AJ: CONTENTS:

8 8

Page 3: 11 (Brodski i Offshor Kablovi)

1. OP]ENITO

2. OZNAKE KABELA

Ovim katalogom ELKA uvodi na tr`i{te novu generaciju

nehalogenih, te{ko gorivih, vatrootpornih brodskih i offshore

kabela, slijede}ih glavnih karakteristika:

- reducirano {irenje plamena

- reducirano ispu{tanje dimnih plinova

- produ`eno funkcioniranje kabela u uvjetima vatre

- odsustvo halogenih materijala

- odsustvo toksi~nih plinova u uvjetima vatre

- otpornost na ulja i maziva

- otpornost na struganje i vibracije

- manji promjeri i te`ine kabela

- jednostavnije polaganje u skladu sa zahtjevima standarda

"IEC 92: Elektri~na instalacija na brodovima" i propisima

Dru{tava za izdavanje certifikata kao {to su: Lloyd's Register

of Shipping, Det Norske Veritas, Bureau Veritas, RINA,

Germanische Lloyd's, Hrvatski registar brodova i drugi.

Nova generacija brodskih kabela je provjerena brojnim

ispitivanjima u doma}im i vanjskim laboratorijama tokom

razvoja, atestiranja i postupcima komercijalnog prihva}anja.

Ugra|ena izolacija i za{titni materijali pla{ta su poliolefinske

smjese, bez halogena, ispitane prema IEC 754-1, djelomi~no

na{e vlastite proizvodnje, a sposobnost samostalnog ga{enja

ugra|enih materijala pobolj{ava otpornost na {irenje plamena

du` kabela, kako je ispitano prema IEC 332-3 za kategoriju

A, uz znatno smanjenje koli~ine i gusto}e plinova, kako je

ispitano prema IEC 1034.

Sva ispitivanja tokom proizvodnje kabela provedena su u

skladu s Programom kontrole prema postupcima Sistema za

osiguranje kvalitete, za koji je ELKA dobila certifikat ISO 9001

od SGS-ICSAG.

U tehni~koj dokumentaciji i narud`bama kabeli su ozna~eniprema oznakama iz poglavlja Tipovi kabela u ovom katalogu, saslijede}im zna~enjima:

Brodski energetski i kontrolni kabeli od 0,6/1 kV do0,6/10 kVBrodski telekomunikacijski i instrumentacijski kabeliza 60 V, 250 V i 0,6/1 kVUmre`eni polietilen (XLPE)

Poluvodljivi XLPE slojevi s bakrenim ekranom

Ekran od individualnih parica i zajedni~ki ekran odmetalizirane poliesterske trake s pokositrenom bakre-nom odvodnom `icomZajedni~ki ekran od metalizirane poliesterske trake spokositrenom bakrenomodvodnom`icomEkran (oplet) od bakrenih ili pokositrenih bakrenih`icaPoliolefin

Bez halogenih materijala

Te{ko goriv

Vatrootporan

Elektromagnetska kompatibilnost

600

60

60

6

B -

TB -

X -H -(Z) -

(Z1) -

Z -

O -HF -TG -VO -

EMC -J -Oznaka za zeleno/`utu `ilu

1. GENERAL

2. CABLE DESIGNATION

By the present catalogue ELKA is introducing to the market

and new generation of halogen free, flame-retardant and

flame-resistant shipboard and off shore cables whose main

features are:

- reduced flame propagation

- reduced emission of smoke-gasses

- prolonged cable function in fire conditions

- absence of halogenous materials

- absence of toxic gasses in fire conditions

- resistance to oils and lubricants

- resistance to scraping and vibrations

- smaller diameters and cable weights

- easier layingpursuant to the requests of the standard "IEC

92: Electrical installation in ships" and the regulations of

the Certification societies such as: Lloyd's Register of Ship

ping, Det Norske Veritas, Bureau Veritas, RINA, Germa

nische Lloyd's, Croatian Register of Shipping, and others.

The new generation of the shipboard cables has been checked

in a number of tests in indoor and exterior laboratories during

the development, certification and commercial- acceptance

procedures.

The fitted insulation and protective sheaths materials, are

halogen free, polyolefyne compounds, tested acc. to IEC

754-1, partly of our own production, the self-extinguishing

feature of the fitted materials improves the resistance to the

flame-propagation along the cables, as tested acc. to IEC

332-3 for category A, along with the considerable reduction

of the gas quantity and density, as checked acc. to IEC 1034.

All examinations during the cable production are performed in

accoradance with the Control Programme under the proce

dures of the Quality Assurance System, for witch ELKA has

received ISO 9001 Certificate from SGS-ICSAG.

In the technical documentation and orders the cable are

marked according to the designations in Chapter Cable types

of the present catalogue, bearing the following meaning:

Shipboard power and control cable from 0, 6/1 kV up

to 6/10 kV

Telecommunications and Instrumentation, shipboard

cable for 60 V, 250 V and 0,6/1 kV

Cross-linked polyethylene (XLPE)

Semiconductive XLPE layers with copper screen

Individual pair and common screen of metalized

polyester tape with tinned copper drain wire

Common screen of metalized polyester tape with

tinned copper drain wire

Cu wires or Cu tinned wires screen (braid)

Polyolefine

Halogen free

Fire retardant

Fire resistant

600

-

-

60

60

6

-

B -

TB -

X -

H -

(Z) -

(Z1) -

Z -

O -

HF -

TG -

VO -

J -

EMC

Designation for green/yellow core

Electromagnetic compa bility- ti

1E L K A d . d . , @ i t n j a k b . b . , H R - 1 0 0 0 0 Z A G R E B , C R O A T I A , T e l . : ( 0 1 ) 2 4 8 2 6 0 0 , F a x . : ( 0 1 ) 2 4 0 4 8 9 8

TVORNICA ELEKTRI^NIH KABELA ELECTRIC CABLE WORKS

Brodski i offshore kabeli Shipboard and offshore cables

Page 4: 11 (Brodski i Offshor Kablovi)

OPIS KONSTRUKCIJE1. Vodi~:

2. Separator:3. Izolacija:4. Ispuna:5. Pla{t:

ELKA CS ATOX-MARIN BXO-HFTG nxSmm0,6/1 kV IEC 60092-353, IEC 60332-3A

Boje izolacije:

Jedno`ilni:Dvo`ilni:

Sedmero i vi{e`ilni:Boja pla{ta:

pokositrena bakrena `ica, klasa 2, IEC 228,(50 mm do 300 mm okruglog ili sektorskog oblika)Vidi tablicu 13

prema zahtjevu

XLPE, prema IEC 60092-351

smjesa na bazi poliolefina

poliolefin, tip SHF 1 prema IEC 92-359(SHF 2 na zahtjev)

crna ili siva

crna, plava

bijela ili crna s brojevima 1 ... n

crna ili siva

2 2

600

OZNAKA NA PLA[TU2

Tro`ilni:^etvero`ilni:Petero`ilni:

crna, plava, sme|a (ili zeleno/`uta)

crna, plava, sme|a, bijela (ili zeleno/`uta)

crna, crna, plava, sme|a, bijela (ili zeleno/`uta)

3.1 NEARMIRANI, TE[KO GORIVI KABEL BEZHALOGENA 0,6/1 kV

Konstrukcija i ispitivanje premastandarduMaksimalna radna temperatura vodi~aNominalni naponlspitni naponIspitivanje zapaljivostiIspitivanje na korozijuIspitivanje gusto}e dima

IEC 92-350, IEC 92-353

85 C

0,6/1 kV

3,5 kV

IEC 332-1, IEC 332-3/kat. A

IEC 754-1

IEC 1034

600 600

60 60

60

6

0

. . . . . . . . . .................. .

. . . . . ............ . . . . .

. . . . . . . . . . . . . . ...................... . . . . . . . . .

. . . . . . . . . . . . ......................... . . . . . . . . . . . . . . . .

. ........

. . . . . . . ................... . . . . . . . ..

. . . . . . . . .............................

CONSTRUCTION DESCRIPTION1. Conductor:

2. Separator:

3. Insulation:

4. Filler:

5. Sheath:

ELKA CS ATOX-MARIN BXO-HFTG nxSmm

0,6/1 kV IEC 60092-353, IEC 60332-3A

Insulation colours:

Single-core:

Two-cores:

Seven- and multicore:

Sheath colour:

tinned copper wire, class 2, IEC 228

as required

XLPE, acc. to IEC 60092-351

compound on the polyolefine basis

polyolefine, type SHF 1 acc. to IEC 60092-359

(SHF 2 on request)

black or gray

black, blue

white or black with numbers 1 ... n

black or gray

(50 mm up to 300 mm round or sector-

shaped) See Table 13

black, blue, brown (or gr/ye)

black, blue, brown, white (or gr/ye)

black, black, blue, brown, white (or gr/ye)

2 2

SHEATH MARKING2

Three-cores:

Four-cores:

Five-cores:

3.1 UNARMOURED, FIRE RETARDANT

0,6/1 kV CABLE

,

HALOGEN FREE

Construction and testing according to

standards

Nominal voltage

Testing voltage

Inflammability test

Corrosion test

Smoke density test

IEC 60092-350, IEC 60092-353

0,6/1 kV

3,5 kV

IEC 60332-1, IEC 60332-3/cat.A

IEC 60754-1

IEC 61034

Maximum operating temperature of conductor 85 C0

. . . . . .. . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . ... . .

. . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . .

................ . .

.

12345

2

TVORNICA ELEKTRI^NIH KABELA ELECTRIC CABLE WORKS

Brodski i offshore kabeli Shipboard and offshore cables

BXO-HFTG

E L K A d . d . , @ i t n j a k b . b . , H R - 1 0 0 0 0 Z A G R E B , C R O A T I A , T e l . : ( 0 1 ) 2 4 8 2 6 0 0 , F a x . : ( 0 1 ) 2 4 0 4 8 9 8

Page 5: 11 (Brodski i Offshor Kablovi)

Tablica 1. BXO-HFTG 0,6/1 kVKonstrukcijski podaci za kabel Table 1. BXO-HFTG 0,6/1 kVConstruction data of cable

1x1,5

1x2,5

1x4

1x6

1x10

1x16

1x25

1x35

1x50

1x70

1x95

1x120

1x150

1x185

1x240

1x300

2x1

2x1,5

2x2,5

2x4

2x6

2x10

2x16

2x25

2x35

2x50

2x70

2x95

2x120

2x150

2x185

2x240

2x300

3x1

3x1,5

3x2,5

3x4

3x6

3x10

3x16

3x25

3x35

3x50

3x70

3x95

3x120

3x150

3x185

3x240

3x300

0,7

0,7

0,7

0,7

0,7

0,7

0,9

0,9

1,0

1,1

1,1

1,2

1,4

1,6

1,7

1,8

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,9

0,9

1,0

1,1

1,1

1,2

1,4

1,6

1,7

1,8

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,9

0,9

1,0

1,1

1,1

1,2

1,4

1,6

1,7

1,8

1,0

1,0

1,0

1,0

1,0

1,1

1,1

1,2

1,2

1,3

1,4

1,5

1,5

1,6

1,7

1,8

1,0

1,1

1,1

1,1

1,2

1,2

1,3

1,4

1,5

1,6

1,8

1,9

2,1

2,2

2,3

2,5

2,7

1,0

1,1

1,1

1,1

1,2

1,2

1,4

1,5

1,6

1,6

1,7

1,8

2,0

2,1

2,2

2,4

2,6

5,0

5,5

6,0

6,5

7,5

8,5

10,0

11,5

13,0

15,0

17,0

19,0

22,0

23,5

26,0

29,0

7,5

8,0

9,0

10,0

11,0

12,5

14,0

18,0

20,5

24,0

29,0

33,0

36,0

39,0

44,0

50,0

56,0

8,0

9,0

10,0

11,0

12,5

14,0

16,5

20,0

23,0

S 23,0 27,0

S 26,0 31,0

S 29,0 35,0

S 33,0 39,0

S 37,0 43,0

S 41,0 48,0

S 45,0 52,0

S 52,0 60,0

30

35

40

45

50

60

70

80

90

100

120

130

150

160

180

200

45

50

60

65

70

80

90

120

130

160

190

215

235

250

290

320

360

50

60

65

70

80

90

110

130

150

160

170

190

220

240

260

290

330

20

28

38

48

67

90

120

145

180

225

275

320

365

415

490

560

14

17

24

32

41

57

77

102

123

153

191

234

272

310

353

417

476

11

14

20

27

34

47

63

84

102

126

158

193

224

256

291

343

392

40

45

70

90

130

195

285

400

540

750

1010

1260

1570

1930

2470

3060

90

100

135

180

245

360

530

775

1070

1450

2010

2720

3380

4240

5230

6760

8350

95

120

160

220

310

450

680

990

1350

1750

2400

3250

4100

5100

6250

8000

10000

3

TVORNICA ELEKTRI^NIH KABELA ELECTRIC CABLE WORKS

Brodski i offshore kabeli Shipboard and offshore cables

KonstrukcijaConstruction

nxmm2

1

Nominalna debljinaizolacije

Nominal thickness ofinsulat.

mm

2

Nominalna debljinapla{ta

Nominal thickness ofsheath

mm

3

Vanjski promjer ccaExternal diameter

approx.

mm

4

Minimalni radiussavijanja

Minimal bendingradius

mm

5

Te`ina kabela cca

kg/km

6

Cable weight

approx.

Strujnooptere}enjeCurrent load

A

7

E L K A d . d . , @ i t n j a k b . b . , H R - 1 0 0 0 0 Z A G R E B , C R O A T I A , T e l . : ( 0 1 ) 2 4 8 2 6 0 0 , F a x . : ( 0 1 ) 2 4 0 4 8 9 8

Page 6: 11 (Brodski i Offshor Kablovi)

Tablica 1. Nastavak Table 1. Continued

7654321

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,9

0,9

1,0

1,1

1,1

1,2

1,4

1,6

1,7

1,8

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

4x1

4x1,5

4x2,5

4x4

4x6

4x10

4x16

4x25

4x35

4x50

4x70

4x95

4x120

4x150

4x185

4x240

4x300

5x1

7x1

10x1

12x1

14x1

16x1

19x1

24x1

27x1

30x1

37x1

48x1

61x1

5x1,5

7x1,5

10x1,5

12x1,5

14x1,5

16x1,5

19x1,5

24x1,5

27x1,5

30x1,5

37x1,5

48x1,5

61x1,5

5x2,5

7x2,5

10x2,5

12x2,5

14x2,5

16x2,5

19x2,5

24x2,5

27x2,5

30x2,5

37x2,5

48x2,5

61x2,5

1,0

1,1

1,2

1,2

1,2

1,3

1,4

1,6

1,7

1,8

2,0

2,1

2,2

2,4

2,6

2,8

2,9

1,1

1,1

1,2

1,2

1,2

1,3

1,3

1,4

1,4

1,4

1,5

1,6

1,7

1,1

1,1

1,2

1,2

1,3

1,3

1,4

1,4

1,5

1,5

1,6

1,7

1,8

1,1

1,2

1,3

1,3

1,4

1,4

1,4

1,6

1,6

1,6

1,7

1,8

1,9

9,0

10,0

11,0

12,0

13,5

15,0

18,0

22,0

25,0

S 28,0 31,0

S 33,0 37,0

S 37,0 42,0

S 40,0 46,0

S 45,0 51,0

S 50,0 57,0

S 55,0 63,0

S 60,0 68,0

10,0

11,0

14,0

14,5

15,0

16,0

17,0

19,5

20,0

21,0

23,0

26,0

29,0

10,5

11,5

14,0

15,0

16,0

17,0

18,0

20,0

21,0

22,0

24,0

27,0

30,0

12,0

13,0

16,0

17,0

18,0

19,0

20,0

23,0

24,0

25,0

27,0

32,0

34,0

55

65

70

80

90

100

120

140

160

170

200

230

250

280

320

350

380

65

70

90

95

95

100

110

125

130

135

150

170

190

70

75

85

90

100

110

120

130

135

140

160

180

200

75

80

100

110

115

120

130

140

150

160

180

200

220

115

150

210

290

390

580

880

1330

1810

2350

3300

4400

5450

6900

8500

10800

13400

145

180

250

280

310

350

400

515

560

610

730

920

1150

180

225

310

360

410

460

535

660

730

810

965

1230

1520

230

300

420

490

560

630

730

920

1010

1110

1340

1710

2130

11

14

20

27

34

47

63

84

102

126

158

193

224

256

291

343

392

11

8

7

6

6

6

6

5

5

4

4

3

3

14

10

9

8

8

7

7

6

6

5

5

4

4

20

14

13

11

10

10

9

8

7

7

6

6

5

4

TVORNICA ELEKTRI^NIH KABELA ELECTRIC CABLE WORKS

Brodski i offshore kabeli Shipboard and offshore cables

E L K A d . d . , @ i t n j a k b . b . , H R - 1 0 0 0 0 Z A G R E B , C R O A T I A , T e l . : ( 0 1 ) 2 4 8 2 6 0 0 , F a x . : ( 0 1 ) 2 4 0 4 8 9 8

Page 7: 11 (Brodski i Offshor Kablovi)

3.2 ARMIRANI, TE[KO GORIVI KABEL BEZHALOGENA 0,6/1 kV

Konstrukcija i ispitivanje premastandarduMaksimalna radna temperatura vodi~aNominalni naponIspitni naponIspitivanje zapaljivostiIspitivanje na korozijuIspitivanje gusto}e dima

IEC 60092-350, IEC 92-353

85 C

0,6/1 kV

3,5 kV

IEC 60332-1, IEC 60332-3/kat. A

IEC 60754-1

IEC 61034

6000

. . . . . . . . ....................

. ................. . . . . .

. . . . . . . . . . . . . . .............................. . .

. . . . . . . . ....................................... . . . . . . . . . . .

. . .... .

. . . ....................... . . . . . . . . .

. . . . . .......................... . . . . .

OPIS KONSTRUKCIJE1. Vodi~:

2. Separator:3. Izolacija:4. Ispuna i unutra{nji

pla{t:5. Armatura:

6. Pla{t:

ELKA CS ATOX-MARIN BXOZO-HFTG nxSmm0,6/1 kV IEC 60092-353, IEC 60332-3A

Boje izolacije:

Jedno`ilni:Dvo`ilni:Tro`ilni:^etvero `ilni:Petero `ilni:Sedmero i vi{e`ilni:Boja pla{ta:

pokositrena bakrena `ica, klasa 2, IEC 60228,(50 mm do 300 mm okruglog ili sektorskogoblika) Vidi 13

prema zahtjevu

XLPE, prema IEC 60092-351

smjesa na bazi poliolefina

oplet od pokositrenih bakrenih `ica(minimalna gusto}a 90%)

poliolefin, tip SHF 1 prema IEC 60092-359(SHF 2 na zahtjev)

crna ili siva

crna, plava

crna, plava, sme|a (ili

crna, plava, sme|a, bijela (ili

crna, crna, plava, sme|a, bijela (ili

bijela ili crna s brojevima 1 ... n

crna ili siva

2 2

tablicu

zeleno/`uta)

zeleno/`uta)

zeleno/`uta)

OZNAKA NA PLA[TU2

3.2 ARMOURED,

HALOGEN FREE 0,6/1 kV CABLE

FIRE RETARDANT,

Construction and testing according to

standards

Maximum operating temperature of conductor

Nominal voltage

Testing voltage

Inflammability test

Corrosion test

Smoke density test

IEC 60092-350, IEC 60092-353

85 C

0,6/1 kV

3,5 kV

IEC 332-1, IEC 332-3/cat.A

IEC 60754-1

IEC 61034

0

. . . . . . . . ...... . . . .

.......... .

. . . . . . . . . ............ . . . . . . . . .

. . . . . . . .................. . . . . . . . . . . . .

. . . ..........

. . . . . ......... . . . . . . . . . . . .

. . . . ......... . . . . . . . . . . . .

........

60 60

CONSTRUCTION DESCRIPTION1. Conductor:

2. Separator:

3. Insulation:

4. Filler and inner

covering:

5. Armour:

6.Sheath:

ELKA CS ATOX-MARIN BXOZO-HFTG nxSmm

0,6/1 kV IEC 60092-353, IEC 60332-3A

Insulation colours:

Single-core:

Two-cores:

Three-cores:

Four-cores:

Five-cores:

Seven- and multicore:

Sheath colour:

tinned copper wire, class 2, IEC 60228

(50 mm² up to 300 mm round or sector-shaped)

See Table 13

as required

XLPE, acc. to IEC 60092-351

compound on the polyolefine basis

tinned copper wires braiding

(minimum clensity 90%)

polyolefine, type SNF 1 acc. to IEC 60092-359

(SHF 2 on request)

black or gray

black, blue

black, blue, brown (or

black, blue, brown, white (or

black, black, blue, brown, white (or

white or black with numbers 1 ... n

black or gray

2

SHEATH MARKING2

gr/ye)

gr/ye)

gr/ye)

123456

5

TVORNICA ELEKTRI^NIH KABELA ELECTRIC CABLE WORKS

Brodski i offshore kabeli Shipboard and offshore cables

BXOZO-HFTG

E L K A d . d . , @ i t n j a k b . b . , H R - 1 0 0 0 0 Z A G R E B , C R O A T I A , T e l . : ( 0 1 ) 2 4 8 2 6 0 0 , F a x . : ( 0 1 ) 2 4 0 4 8 9 8

Page 8: 11 (Brodski i Offshor Kablovi)

Tablica 2. BXOZO-HFTG 0,6/1 kVKonstrukcijski podaci za kabel Table 2. BXOZO-HFTG 0,6/1 kVConstruction data of cable

1x1,5

1x2,5

1x4

1x6

1x10

1x16

1x25

1x351x50

1x70

1x95

1x120

1x150

1x185

1x240

1x300

2x1

2x1,5

2x2,5

2x4

2x6

2x10

2x16

2x25

2x35

2x50

2x70

2x95

2x120

2x150

2x185

2x240

2x300

3x1

3x1,5

3x2,5

3x4

3x6

3x10

3x16

3x25

3x35

3x50

3x70

3x95

3x120

3x150

3x185

3x240

3x300

0,7

0,7

0,7

0,7

0,7

0,7

0,9

0,9

1,0

1,1

1,1

1,2

1,4

1,6

1,7

1,8

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,9

0,9

1,0

1,1

1,1

1,2

1,4

1,6

1,7

1,8

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,9

0,9

1,0

1,1

1,1

1,2

1,4

1,6

1,7

1,8

1,0

1,0

1,1

1,1

1,1

1,2

1,2

1,3

1,3

1,4

1,5

1,5

1,6

1,7

1,8

1,9

1,1

1,1

1,2

1,2

1,3

1,3

1,4

1,5

1,6

1,7

1,9

2,0

2,2

2,3

2,5

2,7

2,9

1,1

1,2

1,2

1,2

1,3

1,4

1,5

1,6

1,7

1,7

1,8

1,9

2,1

2,2

2,4

2,5

2,8

8,0

8,5

9,0

9,5

10,5

12,0

13,5

15,5

17,0

19,0

21,0

23,0

25,5

28,0

31,0

33,5

11,0

12,0

13,0

14,0

16,0

18,0

20,0

23,5

26,0

29,0

33,0

38,0

42,5

47,0

52,0

29,0

64,0

11,5

12,5

13,5

14,5

16,0

19,0

21,0

25,0

28,0

S 27,0 31,0

S 29,0 34,0

S 33,0 39,0

S 37,0 43,0

S 41,0 47,0

S 46,0 53,0

S 49,0 56,0

S 56,0 64,0

50

55

60

65

65

70

85

95

110

120

130

140

160

170

200

210

60

70

80

85

100

110

120

150

160

180

200

240

260

290

320

370

400

70

75

85

90

95

120

130

160

180

170

190

220

240

270

300

320

360

95

120

140

160

220

300

410

570

730

970

1250

1530

1860

2260

2830

3450

175

195

235

300

405

550

750

1040

1360

1790

2420

3410

4080

4960

6090

7670

9400

180

210

265

350

455

640

900

1280

1690

2100

2800

3700

5600

5280

5800

7150

11100

20

28

38

48

67

90

120

145

180

225

275

320

365

415

490

560

14

17

24

32

41

57

77

102

123

153

191

234

272

310

353

417

476

11

14

20

27

34

47

63

84

102

126

158

193

224

256

291

343

392

TVORNICA ELEKTRI^NIH KABELA ELECTRIC CABLE WORKS

Brodski i offshore kabeli Shipboard and offshore cables

6

KonstrukcijaConstruction

nxmm

1

2

Nominalna debljinaizolacije

Nominal thickness ofinsulat.

mm

2

Nominalna debljinapla{ta

mm

3

Nominal thickness ofsheath

Vanjski promjer ccaExternal diameter

approx.

mm

4

Minimalni radiussavijanja

Minimal bendingradius

mm

5

Te`ina kabela cca

kg/km

6

Cable weight

approx.

Strujnooptere}enjeCurrent load

A

7

E L K A d . d . , @ i t n j a k b . b . , H R - 1 0 0 0 0 Z A G R E B , C R O A T I A , T e l . : ( 0 1 ) 2 4 8 2 6 0 0 , F a x . : ( 0 1 ) 2 4 0 4 8 9 8

Page 9: 11 (Brodski i Offshor Kablovi)

Tablica 2. Nastavak Table 2. Continued

7654321

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,9

0,9

1,0

1,1

1,1

1,2

1,4

1,6

1,7

1,8

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

4x1

4x1,5

4x2,5

4x4

4x6

4x10

4x16

4x25

4x35

4x50

4x70

4x95

4x120

4x150

4x185

4x240

4x300

5x1

7x1

10x1

12x1

14x1

16x1

19x1

24x1

27x1

30x1

37x1

48x1

61x1

5x1,5

7x1,5

10x1,5

12x1,5

14x1,5

16x1,5

19x1,5

24x1,5

27x1,5

30x1,5

37x1,5

48x1,5

61x1,5

5x2,5

7x2,5

10x2,5

12x2,5

14x2,5

16x2,5

19x2,5

24x2,5

27x2,5

30x2,5

37x2,5

48x2,5

61x2,5

1,2

1,2

1,2

1,3

1,3

1,4

1,5

1,7

1,8

1,9

2,1

2,2

2,3

2,5

2,7

2,9

3,1

1,2

1,2

1,3

1,4

1,4

1,4

1,4

1,5

1,6

1,6

1,6

1,8

1,8

1,2

1,3

1,4

1,4

1,4

1,5

1,5

1,6

1,6

1,7

1,7

1,9

2,0

1,3

1,3

1,5

1,5

1,5

1,5

1,6

1,7

1,7

1,8

1,8

2,0

2,1

12,0

13,0

14,5

16,0

18,0

20,0

23,0

27,0

30,0

S 31,5 35,0

S 37,0 41,0

S 41,0 46,0

S 44,0 50,0

S 49,0 55,0

S 54,0 61,0

S 60,0 67,0

S 65,0 73,0

13,5

14,0

17,0

18,0

18,5

19,5

20,0

23,0

24,0

24,5

26,0

29,5

32,0

14,5

15,5

18,0

19,0

20,0

21,5

22,0

25,0

26,0

27,0

29,0

33,0

36,0

16,0

17,0

20,0

21,0

22,0

23,0

25,0

28,0

29,0

30,0

32,0

36,0

40,0

70

80

90

100

110

120

140

170

190

200

230

260

280

310

340

380

410

80

85

100

110

115

120

130

140

150

150

160

180

200

90

100

110

120

125

130

140

150

160

170

180

210

220

95

100

120

130

135

140

150

170

180

190

200

230

250

175

240

325

420

585

800

1140

1600

2160

2750

3800

5050

6200

7500

9350

12000

14650

250

320

410

470

515

565

630

765

795

880

1020

1250

1500

315

400

520

585

630

690

770

940

1010

1110

1320

1580

1990

420

510

640

735

795

880

930

1250

1340

1460

1730

2200

2760

11

14

20

27

34

47

63

84

102

126

158

193

224

256

291

343

392

11

8

7

6

6

6

6

5

5

4

4

3

3

14

10

9

8

8

7

7

6

6

5

5

4

4

20

14

13

11

10

10

9

8

7

7

6

6

5

TVORNICA ELEKTRI^NIH KABELA ELECTRIC CABLE WORKS

Brodski i offshore kabeli Shipboard and offshore cables

57E L K A d . d . , @ i t n j a k b . b . , H R - 1 0 0 0 0 Z A G R E B , C R O A T I A , T e l . : ( 0 1 ) 2 4 8 2 6 0 0 , F a x . : ( 0 1 ) 2 4 0 4 8 9 8

Page 10: 11 (Brodski i Offshor Kablovi)

3.2 EKRANIZIRANI, TE[KO GORIVI KABEL SASVOJSTVIMA ELEKTROMAGNETSKEKOMPATIBILNOSTI (EMC) 0,6/1 kV

Konstrukcija i ispitivanje premastandarduMaksimalna radna temperatura vodi~aNominalni naponIspitni naponIspitivanje zapaljivostiIspitivanje na korozijuIspitivanje gusto}e dima

IEC 60092-350, IEC

85 C

0,6/1 kV

3,5 kV

IEC 60332-1, IEC 60332-3/kat. A

IEC 60754-1

IEC 61034

60092-3530

. . . . . . . . ................ . . .

. ................. . . . . .

. . . . . . . . . . . . . . .............................. . .

. . . . . . . . ....................................... . . . . . . . . . . .

. ...... .

. . . ........................... . . . . . . .

. . . . . ......................... . . . . . .

OPIS KONSTRUKCIJE1. Vodi~:

2. Separator:3. Izolacija:4. Ispuna i unutra{nji

pla{t:5. Armatura:

6. Pla{t:

ELKA CS ATOX-MARIN BXOZO-HFTG EMC nxSmm0,6/1 kV IEC 60092-353, IEC 60332-3A

Frekvencijsko podru~je:Transfer impedancija:Ekransko prigu{enje:

pokositrena bakrena `ica, klasa 2, IEC 60228,(50 mm do 300 mm sektorskog oblika)

prema zahtjevu

XLPE, prema IEC 60092-351

smjesa na bazi poliolefina

oplet od pokositrenih bakrenih `ica(minimalna gusto}a 90% + bakar-poliestertraka omotana, bakrena strana u kontaktu sopletom)

poliolefin, tip SHF 1 prema IEC 60092-359(SHF 2 na zahtjev)

0,1 do 500 MHz

manja od 100 m /m

ve}e od 60 dB

Za spajanje motora upravljanih preko frekvencijskihpretvara~a.

2 2

OZNAKA NA PLA[TU

SVOJSTVA ELEKTROMAGNETSKEKOMPATIBILNOSTI (EMC)

MJESTO PRIMJENE U BRODSKIM INSTALACIJAMA

2

Ù

3.2 SCREENED, FIRE RETARDANT WITH

ELECTROMAGNETIC COMPACTABILITY

0,6/1 kV CABLE

Construction and testing

standards

Maximum operating temperature of conductor

Nominal voltage

Test voltage

Inflammability test

Corrosi test

Smoke density test

according to

on

IEC 60092-350, IEC 92-353

85 C

0,6/1 kV

3,5 kV

IEC 60332-1, IEC 60332-3/cat. A

IEC 60754-1

IEC 61034

6000

. . . . . ............... . . .

.......... .

. . . . . . . . . ............ . . . . . . . . .

. . . . . . . .... .............. . . . . . . . . . . . .

. . . ..... . .

. . . . . .. ..... . . . . . . . . ........... . .

. . . . ......... . . . . . .......... . . . . .

.......

..........

...

CONSTRUCTION DESCRIPTION1. Conductor:

2. Separator:

3. Insulation:

4. Filler and inner

:

5. Armour:

6. Sheath:

tinned copper wire, class 2, IEC 60228

(50 mm² up to 300 mm sector-shaped)

as required

XLPE, acc. to IEC 60092-351

compound on the polyolefine basis

tinned copper wires braiding (minimum clensity

90% +

)

polyolefine, type SNF 1 acc. to IEC 60092-359

(SHF 2 on request)

2

sheath

wrapped copper-polyester tape, copper

side in contact with braiding

0,1 up to 500 MHz

less than 100 m/m

exceeding 60 dB

Connection of motors controlled through frequency converters.

SHEATH DESIGNATION

ELECTROMAGNETIC COMPATIBILITY

PROPERTIES (EMC)

AREA OF APPLICATION IN SHIPBOARD INSTALLATIONS

ELKA CSATOX-MARIN BXOZO-HFTG EMC nxS mm 0,6/1 kV

IEC 60092-353, IEC 60332-3A

Frequency area:

Impedance transfer:

Screen attenuation:

2

123456

8

TVORNICA ELEKTRI^NIH KABELA ELECTRIC CABLE WORKS

Brodski i offshore kabeli Shipboard and offshore cables

BXOZO-HFTG EMC

E L K A d . d . , @ i t n j a k b . b . , H R - 1 0 0 0 0 Z A G R E B , C R O A T I A , T e l . : ( 0 1 ) 2 4 8 2 6 0 0 , F a x . : ( 0 1 ) 2 4 0 4 8 9 8

Page 11: 11 (Brodski i Offshor Kablovi)

Tablica 3.BXOZO-HFTG EMC 0,6/1 kVKonstrukcijski podaci za kabel Table 3.

BXOZO-HFTG EMC 0,6/1 kV

Construction data of

cable

3x35

3x50

3x70

3x95

3x120

3x150

4x6

4x16

4x35

0,9

1,0

1,1

1,1

1,2

1,4

0,7

0,7

0,9

1,7

1,7

1,9

1,9

2,1

2,2

1,3

1,5

1,8

28,5

29,0

32,0

35,0

39,0

43,0

18,5

22,5

30,0

190

180

190

220

240

270

100

140

190

1770

1970

2820

3610

4580

5810

650

1130

2200

102

126

158

193

224

256

34

63

102

TVORNICA ELEKTRI^NIH KABELA ELECTRIC CABLE WORKS

Brodski i offshore kabeli Shipboard and offshore cables

9

KonstrukcijaConstruction

nxmm

1

2

Nominalna debljinaizolacije

Nominal thickness ofinsulat.

mm

2

Nominalna debljinapla{ta

mm

3

Nominal thickness ofsheath

Vanjski promjer ccaExternal diameter

approx.

mm

4

Minimalni radiussavijanja

Minimal bendingradius

mm

5

Te`ina kabela cca

kg/km

6

Cable weight

approx.

Strujnooptere}enjeCurrent load

A

7

E L K A d . d . , @ i t n j a k b . b . , H R - 1 0 0 0 0 Z A G R E B , C R O A T I A , T e l . : ( 0 1 ) 2 4 8 2 6 0 0 , F a x . : ( 0 1 ) 2 4 0 4 8 9 8

Boje izolacije:

Jedno`ilni:Dvo`ilni:Tro`ilni:^etvero `ilni:Petero `ilni:Sedmero i vi{e`ilni:Boja pla{ta:

crna ili siva

crna, plava

crna, plava, sme|a (ili

crna, plava, sme|a, bijela (ili

crna, crna, plava, sme|a, bijela (ili

bijela ili crna s brojevima 1...n

crna ili siva

zeleno/`uta)

zeleno/`uta)

zeleno/`uta)

Insulation colours:

Single-core:

Two-cores:

Three-cores:

Four-cores:

Five-cores:

Seven- and multicore:

Sheath colour:

black or gray

black, blue

black, blue, brown (or gr/ye)

black, blue, brown, white (or gr/ye)

black, black, blue, brown, white (or gr/ye)

white or black with numbers 1 ... n

black or gray

Page 12: 11 (Brodski i Offshor Kablovi)

3.4 EKRANIZIRANI, SREDNJENAPONSKI,ARMIRANI, TE[KO GORIVI KABELBEZ HALOGENA

Konstrukcija i ispitivanje premastandarduMaksimalna radna temperatura vodi~aNominalni naponIspitni naponIspitivanje zapaljivostiIspitivanje na korozijuIspitivanje gusto}e dima

IEC 60092-350, IEC 60092-354

85 C

3,6/6 kV 6/10 kV

11 kV 15 kV

IEC 60332-1, IEC 60332-3/kat. A

IEC 60754-1

IEC 61034

0

. . . . .................... . . . . .

.................. . . . . .

. . . . . . ............................. . . . . .

. . . . . . . . . . .................................... . . . . .

. . .......

. . . . . . .......................... . . . . .

. . . . . ........................... . . . . . .

OPIS KONSTRUKCIJE1. Vodi~:

2. Poluvodljivi slojevi:3. Izolacija:4. Ekran:5. Ispuna i unutra{nji

pla{t:6. Armatura:

7. Pla{t:

ELKA CS ATOX-MARIN BXHOZO-HFTG nxSmm Uo/UkV IEC 92-354, IEC 332-3

Boja pla{ta:

pokositrena okrugla bakrena `ica, klasa 2,IEC 228, idi tablicu 13

SC XLPE

XLPE, prema IEC 92-351

bakrena traka ili bakrena `ica

smjesa na bazi poliolefina

oplet od pokositrenih bakrenih `ica(minimalna gusto}a 90%)

poliolefin, tip SHF 1 prema IEC 92-359(SHF 2 na zahtjev)

crvena ili crna

OZNAKA NA PLA[TU2

60 v

600

600

600 60

3.4 SCREENED, MEDIUM VOLTAGE,

ARMOURED, FIRE RETARDANT,

CABLEHALOGEN FREE

Construction and testing according to

standards

Maximum operating temperature of conductor

Nominal voltage

Testing voltage

Inflammability test

Corrosion test

Smoke density test

IEC 92-350, IEC 92-354

85 C

3,6/6 kV 6/10 kV

11 kV 15 kV

IEC 332-1, IEC 332-3/cat. A

IEC 754-1

IEC 1034

0

. . . . . . ............. . . .

. ............... .

. . . . . . . . .................. . . . . .

. . . . . . . . ..................... . . . . . . . .

. . . ....... .

. . . . . . . . ................... . . . . . . . .

. . . . . . ........... ... . . . . . . . . . .....

600 600

60 60

60

6

CONSTRUCTION DESCRIPTION1. Conductor:

2. Semiconductive layers:

3. Insulation:

4. Screen:

5. Filler and inner

covering:

6. Armour:

7. Sheath:

ELKA CS ATOX-MARlN BXOZO-HFTG nxS mm

Uo/U kV IEC 92-354, IEC 332-3

Sheath colour:

tinned round copper wire, class 2,

IEC 228 see Table 13

SC XLPE

XLPE, acc. to IEC 92-351

copper tape or copper wire

compound on the polyolefine basis

tinned copper wires braiding

(minimum density 90%)

polyolefine, type SF 1 acc. to IEC 92-359

(SHF 2 on request)

red or black

SHEATH MARKING2

60

600

600

,

600 60

134567

2

TVORNICA ELEKTRI^NIH KABELA ELECTRIC CABLE WORKS

Brodski i offshore kabeli Shipboard and offshore cables

10

BXHOZO-HFTG

E L K A d . d . , @ i t n j a k b . b . , H R - 1 0 0 0 0 Z A G R E B , C R O A T I A , T e l . : ( 0 1 ) 2 4 8 2 6 0 0 , F a x . : ( 0 1 ) 2 4 0 4 8 9 8

Page 13: 11 (Brodski i Offshor Kablovi)

Tablica 4. BXHOZO-HFTG 3,6/6 kVKonstrukcijski podaci za kabel Table 4. BXHOZO-HFTG 3,6/3 kVConstruction data of cable

1x25

1x351x50

1x70

1x95

1x120

1x150

1x185

1x240

1x300

3x25

3x35

3x50

3x70

3x95

3x120

3x150

2,5

2,5

2,5

2,5

2,5

2,5

2,5

2,5

2,5

2,8

2,5

2,5

2,5

2,5

2,5

2,5

2,5

1,4

1,4

1,5

1,5

1,6

1,6

1,7

1,8

1,8

1,9

1,9

2,0

2,1

2,2

2,4

2,5

2,6

20,0

21,0

22,5

24,5

26,0

27,5

29,0

31,0

34,0

37,0

38,0

40,0

43,0

48,0

51,0

55,0

58,0

170

190

200

210

230

240

250

270

290

320

330

350

380

410

450

490

510

740

800

1030

1330

1540

1960

2310

2730

3390

4100

2410

2930

3600

4320

5690

6860

8050

120

145

180

225

275

320

365

415

490

560

84

102

126

158

193

224

256

TVORNICA ELEKTRI^NIH KABELA ELECTRIC CABLE WORKS

Brodski i offshore kabeli Shipboard and offshore cables

11

KonstrukcijaConstruction

nxmm2

1

Nominalna debljinaizolacije

Nominal thickness ofinsulat.

mm

2

Nominalna debljinapla{ta

Nominal thickness ofsheath

mm

3

Vanjski promjer ccaExternal diameter

approx.

mm

4

Minimalni radiussavijanja

Minimal bendingradius

mm

5

Te`ina kabela cca

kg/km

6

Cable weight

approx.

Strujnooptere}enjeCurrent load

A

7

E L K A d . d . , @ i t n j a k b . b . , H R - 1 0 0 0 0 Z A G R E B , C R O A T I A , T e l . : ( 0 1 ) 2 4 8 2 6 0 0 , F a x . : ( 0 1 ) 2 4 0 4 8 9 8

Page 14: 11 (Brodski i Offshor Kablovi)

Tablica 5. BXHOZO-HFTG 6/10 kVKonstrukcijski podaci za kabel Table 5. BXHOZO-HFTG 6/10 kVConstruction data of cable

1x25

1x351x50

1x70

1x95

1x120

1x150

1x185

1x240

1x300

3x25

3x35

3x50

3x70

3x95

3x120

3x150

3,4

3,4

3,4

3,4

3,4

3,4

3,4

3,4

3,4

3,4

3,4

3,4

3,4

3,4

3,4

3,4

3,4

1,4

1,5

1,5

1,6

1,7

1,7

1,8

1,8

1,9

2,0

2,0

2,1

2,3

2,4

2,5

2,7

2,8

22,0

23,0

24,5

27,0

28,0

30,0

32,0

33,0

36,0

38,0

41,0

44,0

47,0

52,0

55,0

59,0

62,0

140

150

160

170

180

190

200

210

230

240

260

280

300

320

350

380

400

780

950

1140

1440

1760

2090

2450

2860

3520

4230

2800

2940

4060

5200

6330

7460

8650

120

145

180

225

275

320

365

415

490

560

84

102

126

158

193

224

256

TVORNICA ELEKTRI^NIH KABELA ELECTRIC CABLE WORKS

Brodski i offshore kabeli Shipboard and offshore cables

12

KonstrukcijaConstruction

nxmm2

1

Nominalna debljinaizolacije

Nominal thickness ofinsulat.

mm

2

Nominalna debljinapla{ta

Nominal thickness ofsheath

mm

3

Vanjski promjer ccaExternal diameter

approx.

mm

4

Minimalni radiussavijanja

Minimal bendingradius

mm

5

Te`ina kabela ccaCable weight

approx.

kg/km

6

Strujnooptere}enjeCurrent load

A

7

E L K A d . d . , @ i t n j a k b . b . , H R - 1 0 0 0 0 Z A G R E B , C R O A T I A , T e l . : ( 0 1 ) 2 4 8 2 6 0 0 , F a x . : ( 0 1 ) 2 4 0 4 8 9 8

Page 15: 11 (Brodski i Offshor Kablovi)

3.5 TELEKOMUNIKACIJSKI, ARMIRANl,TE[KO GORIVI KABEL BEZ HALOGENA,60 V - 250 V - 0,6/1 kV

Konstrukcija i ispitivanje premastandardu

Maksimalna radna temperatura vodi~aNominalni naponIspitni naponIspitivanje zapaljivostiIspitivanje na korozijuIspitivanje gusto}e dima

IEC 92-3, IEC 92-350,IEC 92-353, IEC 92-375

85 C

60 V 250 V 0,6/1 kV

1500 V 1500 V 3,5 kV

IEC 332-1, IEC 332-3/kat. A

IEC 754-1

IEC 1034

0

. . . . . ......................... . .

. . . .................. . . .

. . . . ........................... . . . . .

. . . . . . ............................ . . . .

....... .

. . . . . . ....................... . . . . . .

. . . . . . ........................... . . . . .

600 600600 600

60 60

60

6

OPIS KONSTRUKCIJE1. Vodi~:

2. Izolacija:3. Separator:4. Ispuna i unutra{nji

pla{t:5. Armatura:

6. Pla{t:

ELKA CS ATOX-MARIN TBXOZO-HFTG nxSmm60 V/250 V (ili 0,6/1 kV)IEC 92-3, IEC 92-375, IEC 332-3A(ili IEC 92-353, IEC 332-3A)

Boje izolacije:

Konstrukcija parica:

Boja pla{ta:

pokositrena bakrena `ica, klasa 2, IEC 228,Vidi tablicu 23

XLPE, prema IEC 92-351

prema zahtjevu

smjesa na bazi poliolefina

oplet od pokositrenih bakrenih `ica(minimalna gusto}a 90%)

poliolefin, tip SHF 1 prema IEC 92-359(SHF 2 na zahtjev)

Bijela ili crna, s brojevima: 1, 2 ... n

1-2; 3-4; 5-6

siva ili narand`asta

OZNAKA NA PLA[TU2

60

600

600

600 600 60600 60

3.5 TELECOMMUNICATION, FIRE RETARDANT,

CABLE 60 V - 250 V - 0,6/1 kV

ARMOURED, HALOGEN FREE

Construction and testing according to

standards

Maximum operating temperature of conductor

Nominal voltage

Testing voltage

Inflammability test

Corrosion test

Smoke density test

IEC 92-3, IEC 92-350,

IEC 92-353, IEC 92-375

85 C

60 V 250 V 0,6/1 kV

1500 V 1500 V 3,5 kV

IEC 332-1, IEC 332-3/cat. A

IEC 754-1

IEC 1034

0

. . . . . . . ....... . . . . .

. .

. . . . . . . . . . . .

. . . . . . . . . . .

. . . . . .

. . . . . . . . . . . . .. . . . .

. . . . . . . . . .. . . . . . .

......

600 600

600 600

60 60

60

6

CONSTRUCTION DESCRIPTION1. Conductor:

2. Insulation:

3. Separator:

4. Filler and inner

covering:

5. Armour:

6. Sheath:

ELKA CS ATOX-MARIN TBXOZO-HFTG nxSmm

60 V/250 V (or 0,6/1 kV)

IEC 92-3, IEC 92-375, IEC 332-3A

(or IEC 92-353, IEC 332-3A)

Insulation colours:

Pairs construction:

Sheath colour:

tinned copper wire, class 2, IEC 228

See Table 23

XLPE, acc. To IEC 92-351

as required

compound on the polyolefine basis

tinned copper wires braiding

(minimum density 90%)

polyolefine, type SHF 1 acc. to IEC 92-359

(SHF 2 on request)

White or black, numbered: 1, 2 ... n

1-2; 3-4; 5-6

gray or orange

SHEATH MARKING2

60

600

600

600 600 60

600 600

3456 2

TVORNICA ELEKTRI^NIH KABELA ELECTRIC CABLE WORKS

Brodski i offshore kabeli Shipboard and offshore cables

13

TBXOZO-HFTG

1

E L K A d . d . , @ i t n j a k b . b . , H R - 1 0 0 0 0 Z A G R E B , C R O A T I A , T e l . : ( 0 1 ) 2 4 8 2 6 0 0 , F a x . : ( 0 1 ) 2 4 0 4 8 9 8

Page 16: 11 (Brodski i Offshor Kablovi)

3.6 TELEKOMUNIKACIJSKI, ARMIRANI,TE[KO GORIVI KABEL BEZ HALOGENASA ZAJEDNI^KIM EKRANOM60 V - 250 V - 0,6/1 kV

Konstrukcija i ispitivanje premastandardu

Maksimalna radna temperatura vodi~aNominalni naponIspitni naponIspitivanje zapaljivostiIspitivanje na korozijuIspitivanje gusto}e dima

IEC 92-3, IEC 92-350,IEC 92-353, IEC 92-375

85 C

60 V 250 V 0,6/1 kV

1500 V 1500 V 3,5 kV

IEC 332-1, IEC 332-3/kat. A

IEC 754-1

IEC 1034

600 600600 600

60 60

60

6

0

. . . . . . ....................................................

. . . . . . .

. . . . . . . . . .

. . . . . . . . . . .

. . .

. . . . . . . . . . . . .

. . . . . . . . . . . .

OPIS KONSTRUKCIJE1. Vodi~:

2. Izolacija:3. Separator:4. Zajedni~ki ekran:

5. Ispuna i unutra{njipla{t:

6. Armatura:

7. Pla{t:

ELKA CS ATOX-MARIN TBX(Z1)OZO-HFTG nxSmm60 V/250 V (ili 0,6/1 kV)IEC 92-3, IEC 92-375, IEC 332-3A(ili IEC 92-353, IEC 332-3A)

Boje izolacije:

Konstrukcija parica:

Boja pla{ta:

pokositrena bakrena `ica, klasa 2, IEC 228,Vidi tablicu 13

XLPE, prema IEC 92-351

prema zahtjevu

metalizirana poliesterskatraka s odvodnom `icom

smjesa na bazi poliolefina

oplet od pokositrenih bakrenih `ica(minimalna gusto}a 90%)

poliolefin, tip SHF 1 prema IEC 92-359(SHF 2 na zahtjev)

Bijela ili crna, s brojevima: 1, 2 n

1-2; 3-4; 5-6

siva ili narand`asta

60

600

600

OZNAKA NA PLA[TU2

600 600 60600 60

...

3.6 TELECOMMUNICATION, ARMOURED,

HALOGEN FREE CABLE

WITH COMMON SCREEN

60 V - 250 V - 0,6/1 kV

FIRE

RETARDANT,

Construction and testing

standards

Nominal voltage

Testing voltage

Inflammability test

Corrosi test

Smoke density test

according to

on

IEC 92-3, IEC 92-350,

IEC 92-353, IEC 92-375

6O V 250 V 0,6/1 kV

1500 V 1500 V 3,5 kV

IEC 332-1, IEC 332-3/cat. A

IEC 754-1

IEC 1034

600

85 C

600

600 600

60 60

60

6

Maximum operating temperature of conductor0

. . . . . . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . .

. . . . .. . . . . . . . . . . .

. . . . . . . . . . . . . . . . .

. . ........

CONSTRUCTION DESCRIPTION1. Conductor:

2. Insulation:

3. Separator:

4. Common screen:

5. Filler and inner

covering:

6. Armour:

7. Sheath:

ELKA CS ATOX-MARIN TBX(Z1)OZO-HFTG nxSmm

60 V/250 V (or 0,6/1 kV)

IEC 92-3, IEC 92-375, IEC 332-3A

(or IEC 92-353, IEC 332-3A)

Insulation colours:

Pairs construction:

Sheath colour:

tinned copper wire, class 2, IEC 228

See Table 13

XLPE, acc. to IEC 92-351

as required

metalized polyester tape

with drain wire

compound on the polyolefine basis

tinned copper wires braiding

(minimum density 90%)

polyolefine, type SHF 1 acc. to IEC 92-359

(SHF 2 on request)

White or black, numbered: 1, 2 n

1-2; 3-4; 5-6

gray or orange

60

600

600

SHEATH MARKING2

600 600 60

600 60

...

34567 2

1

TVORNICA ELEKTRI^NIH KABELA ELECTRIC CABLE WORKS

Brodski i offshore kabeli Shipboard and offshore cables

14

TBX(Z1)OZO-HFTG

E L K A d . d . , @ i t n j a k b . b . , H R - 1 0 0 0 0 Z A G R E B , C R O A T I A , T e l . : ( 0 1 ) 2 4 8 2 6 0 0 , F a x . : ( 0 1 ) 2 4 0 4 8 9 8

Page 17: 11 (Brodski i Offshor Kablovi)

KonstrukcijaConstruction

nxmm2

1

Nominalna debljinaizolacije

Nominal thickness ofinsulat

mm

2

Nominalna debljinapla{ta

Nominal thickness ofsheath

mm

3

Vanjski promjercca

External diameterapprox.

mm

4

Minimalni radiussavijanja

Minimal bendingradius

mm

5

Te`ina kabela ccaCable weight

approx.

kg/km

6

KonstrukcijaConstruction

nxmm2

1

Nominalna debljinaizolacije

Nominal thickness ofinsulat.

mm

2

Nominalna debljinapla{ta

Nominal thickness ofsheath

mm

3

Vanjski promjercca

External diameterapprox.

mm

4

Minimalni radiussavijanja

Minimal bendingradius

mm

5

Te`ina kabela ccaCable weight

approx.

kg/km

6

Tablica 6.TBXOZO-HFTG TBX(Z1)OZO-HFTG 60/250 VKonstrukcijski podaci za kabel

iTable 6. TBXOZO-HFTG

TBX(Z1)OZO-HFTG 60/250 V

Construction data of and

cable

1x2x0,50

1x3x0,50

2x2x0,50

4x2x0,50

7x2x0,50

10x2x0,50

14x2x0,50

19x2x0,50

24x2x0,50

30x2x0,50

0,5

0,5

0,5

0,5

0,5

0,5

0,5

0,5

0,5

0,5

1,1

1,1

1,1

1,2

1,2

1,3

1,3

1,4

1,4

1,5

9,5

10,0

10,5

13,0

15,5

19,0

20,0

22,0

26,0

27,5

55

55

70

90

100

120

130

150

170

190

120

135

160

220

320

420

490

600

730

850

Tablica 7.TBXOZO-HFTG TBX(Z1)OZO-HFTG 60/250 VKonstrukcijski podaci za kabel

iTable 7. TBXOZO-HFTG

TBX(Z1)OZO-HFTG 60/250 V

Construction data of and

cable

1x2x0,75

1x3x0,75

2x2x0,75

4x2x0,75

7x2x0,75

10x2x0,75

14x2x0,75

19x2x0,75

24x2x0,75

30x2x0,75

0,6

0,6

0,6

0,6

0,6

0,6

0,6

0,6

0,6

0,6

1,1

1,1

1,1

1,2

1,3

1,3

1,4

1,5

1,5

1,6

10,0

10,5

12,0

15,0

17,0

21,0

24,0

26,0

30,0

32,0

65

70

80

95

110

140

160

170

200

210

130

170

190

300

410

520

660

810

1000

1100

TVORNICA ELEKTRI^NIH KABELA ELECTRIC CABLE WORKS

Brodski i offshore kabeli Shipboard and offshore cables

15E L K A d . d . , @ i t n j a k b . b . , H R - 1 0 0 0 0 Z A G R E B , C R O A T I A , T e l . : ( 0 1 ) 2 4 8 2 6 0 0 , F a x . : ( 0 1 ) 2 4 0 4 8 9 8

Page 18: 11 (Brodski i Offshor Kablovi)

Tablica .TBXOZO-HFTG TBX(Z1)OZO-HFTG 0,6/1 kV

8 Konstrukcijski podaci za kabel

iTable . TBXOZO-HFTG

TBX(Z1)OZO-HFTG 0,6/1 kV

8 Construction data of and

cable

1x2x1

1x3x1

2x2x1

4x2x1

7x2x1

10x2x1

14x2x1

19x2x1

24x2x1

30x2x1

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,8

0,8

0,8

0,9

1,0

1,1

1,2

1,2

1,4

1,4

10,5

11,0

12,5

16,0

20,0

24,5

26,5

29,0

34,0

36,0

70

70

75

95

110

150

160

190

210

220

155

180

200

360

500

685

860

1030

1350

1570

Tablica 9.TBXOZO-HFTG TBX(Z1)OZO-HFTG 0,6/1 kVKonstrukcijski podaci za kabel

iTable 9. TBXOZO-HFTG

TBX(Z1)OZO-HFTG 0,6/1 kV

Construction data of and

cable

1x2x1,5

1x3x1,5

2x2x1,5

4x2x1,5

7x2x1,5

10x2x1,5

14x2x1,5

19x2x1,5

24x2x1,5

30x2x1,5

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,8

0,8

0,9

1,0

1,1

1,2

1,2

1,3

1,5

1,5

11,0

11,5

14,0

18,0

21,0

27,0

29,5

33,0

39,0

41,0

80

80

95

120

140

180

190

210

250

270

170

210

280

450

600

840

1010

1330

1750

2070

TVORNICA ELEKTRI^NIH KABELA ELECTRIC CABLE WORKS

Brodski i offshore kabeli Shipboard and offshore cables

16

KonstrukcijaConstruction

nxmm2

1

Nominalna debljinaizolacije

Nominal thickness ofinsulat

mm

2

Nominalna debljinapla{ta

Nominal thickness ofsheath

mm

3

Vanjski promjercca

External diameterapprox.

mm

4

Minimalni radiussavijanja

Minimal bendingradius

mm

5

Te`ina kabela ccaCable weight

approx.

kg/km

6

KonstrukcijaConstruction

nxmm2

1

Nominalna debljinaizolacije

Nominal thickness ofinsulat.

mm

2

Nominalna debljinapla{ta

Nominal thickness ofsheath

mm

3

Vanjski promjercca

External diameterapprox.

mm

4

Minimalni radiussavijanja

Minimal bendingradius

mm

5

Te`ina kabela ccaCable weight

approx.

kg/km

6

E L K A d . d . , @ i t n j a k b . b . , H R - 1 0 0 0 0 Z A G R E B , C R O A T I A , T e l . : ( 0 1 ) 2 4 8 2 6 0 0 , F a x . : ( 0 1 ) 2 4 0 4 8 9 8

Page 19: 11 (Brodski i Offshor Kablovi)

3.7 TELEKOMUNIKACIJSKI, ARMIRANITE[KO GORIVI KABEL BEZ HALOGENA SINDIVIDUALNIM I ZAJEDNI^KIMEKRANOM 60 V - 250 V - 0,6/1 kV

,

Konstrukcija i ispitivanje premastandardu

Maksimalna radna temperatura vodi~aNominalni naponIspitni naponIspitivanje zapaljivostiIspitivanje na korozijuIspitivanje gusto}e dima

IEC 92-3, IEC 92-350,IEC 92-353, IEC 92-375

85 C

60 V 250 V 0,6/1 kV

1500 V 1500 V 3,5 kV

IEC 332-1, IEC 332-3/kat. A

IEC 754-1

IEC 61034

600 600600 600

60 60

60

0

. . . . . . . . . .

. . . . . . . .

. . . . . . . . . .

. . . . . . . . . . .

.

. . . . . . . . . . . .

. . . . . . .. . . .

OPIS KONSTRUKCIJE1. Vodi~:

2. Separator:3. Izolacija:4. Ekran individualnih

parica:

5. Separator:6. Zajedni~ki ekran:

7. Ispuna i unutra{njipla{t:

8. Armatura:

9. Pla{t:

ELKA CS ATOX-MARIN TBX(Z)OZO-HFTG nxS mm60V/250V (ili 0,6/1 kV)IEC 92-3, IEC 92-375, IEC 332-3A(ili IEC 92-353, IEC 332-3A)

Boje izolacije:

Konstrukcija parica:

Boja pla{ta:

pokositrena bakrena `ica, klasa 2, IEC 228,Vidi tablicu 23

prema zahtjevuXLPE, prema IEC 92-351

metalizirana poliesterska trakas odvodnom `icom

prema zahtjevumetalizirana poliesterskatraka s odvodnom `icom

smjesa na bazi poliolefinaoplet od pokositrenih bakrenih `ica(minimalna gusto}a 90%)

poliolefin, tip SHF 1 prema IEC 92-359,(SHF 2 na zahtjev)

Bijela ili crna, s brojevima: 1, 2 n

1-2; 3-4; 5-6

siva ili narand`asta

60

600

600

OZNAKA NA PLA[TU2

600 600 60600 60

...

3.7 TELECOMMUNICATION, ARMOURED,

WITH INDIVIDUAL & COMMON SCREEN,

FIRE RETARDANT, CABLE

60 V - 250 V - 0,6/1 kV

HALOGEN FREE

Construction and testing

standards

Maximum operating temperature of conductor

Nominal voltage

Testing voltage

Inflammability test

Corrosi test

Smoke density test

according to

on

IEC 92-3, IEC 92-350,

IEC 92-353, IEC 92-375

85 C

60 V 250 V 0,6/1 kV

1500 V 1500 V 3,5 kV

IEC 332-1, IEC 332-3/cat.A

IEC 754-1

IEC 1034

600 600

600 600

60 60

60

6

0

. . . . . . . . . . .

. . .

. . . . . . . . . . . .

. . . . . . . . . . .

. . . . .

. . . . . . . . . . . . . .. . .

..............

. . . . . . . . . .. . . . . .

CONSTRUCTION DESCRIPTION1. Conductor:

2. Separator:3. Insulation:4. Individual pair

screen:

5. Separator:6. Common screen:

7. Filler and innercovering:

8. Armour:

9. Sheath:

ELKA CS ATOX-MARIN TBX(Z1)OZO-HFTG nxSmm60V/250V (or 0,6/1 kV)IEC 92-3, IEC 92-375, IEC 332-3A(or IEC 92-353, IEC 332-3A)

Insulation colours:

Pairs construction:

Sheath colour:

tinned copper wire, class 2, IEC 228See Table 23as requiredXLPE, acc. to IEC 92-351

metalized polyester tapewith drain wire

as requiredmetalized poyester tapewith drain wire

compound on the polyolefine basistinned copper wires braiding(minimum density 90%)polyolefine, type SHF 1 acc. to lEC 92-359(SHF 2 on reguest)

White or black, numbered: 1, 2 n

1-2; 3-4; 5-6

gray or orange

60

600

600

SHEATH MARKING2

600 600 60600 60

...

1

456

2

789

34

TVORNICA ELEKTRI^NIH KABELA ELECTRIC CABLE WORKS

Brodski i offshore kabeli Shipboard and offshore cables

17

TBX(Z)OZO-HFTG

E L K A d . d . , @ i t n j a k b . b . , H R - 1 0 0 0 0 Z A G R E B , C R O A T I A , T e l . : ( 0 1 ) 2 4 8 2 6 0 0 , F a x . : ( 0 1 ) 2 4 0 4 8 9 8

Page 20: 11 (Brodski i Offshor Kablovi)

Tablica 10.TBX(Z)OZO-HFTG 60/250 VKonstrukcijski podaci za kabel Table 10.

TBX(Z)OZO-HFTG 60/250 V

Construction data of

cable

1x2x0,50

1x3x0,50

2x2x0,50

4x2x0,50

7x2x0,50

10x2x0,50

14x2x0,50

19x2x0,50

24x2x0,50

30x2x0,50

0,5

0,5

0,5

0,5

0,5

0,5

0,5

0,5

0,5

0,5

1,1

1,1

1,1

1,2

1,2

1,3

1,3

1,4

1,4

1,5

9,5

10,0

11,0

13,5

16,0

20,0

21,0

23,0

27,0

29,0

55

60

70

90

100

120

130

150

170

190

120

135

170

230

340

440

520

630

770

900

Tablica 11.TBX(Z)OZO-HFTG 60/250 VKonstrukcijski podaci za kabel Table 11.

TBX(Z)OZO-HFTG 60/250 V

Construction data of

cable

1x2x0,75

1x3x0,75

2x2x0,75

4x2x0,75

7x2x0,75

10x2x0,75

14x2x0,75

19x2x0,75

24x2x0,75

30x2x0,75

0,6

0,6

0,6

0,6

0,6

0,6

0,6

0,6

0,6

0,6

1,1

1,1

1,1

1,2

1,3

1,3

1,4

1,5

1,5

1,6

10,0

10,5

12,5

15,5

18,0

22,0

25,0

27,0

31,0

33,0

65

70

85

100

120

140

160

180

200

210

130

170

200

320

420

540

690

850

1030

1210

TVORNICA ELEKTRI^NIH KABELA ELECTRIC CABLE WORKS

Brodski i offshore kabeli Shipboard and offshore cables

18

KonstrukcijaConstruction

nxmm2

1

Nominalna debljinaizolacije

Nominal thickness ofinsulat.

mm

2

Nominalna debljinapla{ta

Nominal thickness ofsheath

mm

3

Vanjski promjercca

External diameterapprox.

mm

4

Minimalni radiussavijanja

Minimal bendingradius

mm

5

Te`ina kabela ccaCable weight

approx.

kg/km

6

KonstrukcijaConstruction

nxmm2

1

Nominalna debljinaizolacije

Nominal thickness ofinsulat

mm

2

Nominalna debljinapla{ta

Nominal thickness ofsheath

mm

3

Vanjski promjercca

External diameterapprox.

mm

4

Minimalni radiussavijanja

Minimal bendingradius

mm

5

Te`ina kabela ccaCable weight

approx.

kg/km

6

E L K A d . d . , @ i t n j a k b . b . , H R - 1 0 0 0 0 Z A G R E B , C R O A T I A , T e l . : ( 0 1 ) 2 4 8 2 6 0 0 , F a x . : ( 0 1 ) 2 4 0 4 8 9 8

Page 21: 11 (Brodski i Offshor Kablovi)

Tablica 12.TBX(Z)OZO-HFTG 0,6/1 kVKonstrukcijski podaci za kabel Table 12.

TBX(Z)OZO-HFTG 0,6/1 kV

Construction data of

cable

1x2x1

1x3x1

2x2x1

4x2x1

7x2x1

10x2x1

14x2x1

19x2x1

24x2x1

30x2x1

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,8

0,8

0,8

0,9

1,0

1,1

1,2

1,2

1,4

1,4

10,5

11,0

13,0

17,0

21,0

26,0

27,5

31,0

36,0

38,0

70

70

80

110

130

160

170

190

220

240

155

180

205

370

525

705

900

1100

1420

1640

Tablica 13.TBX(Z)OZO-HFTG 0,6/1 kVKonstrukcijski podaci za kabel Table 13.

TBX(Z)OZO-HFTG 0,6/1 kV

Construction data of

cable

1x2x1,5

1x3x1,5

2x2x1,5

4x2x1,5

7x2x1,5

10x2x1,5

14x2x1,5

19x2x1,5

24x2x1,5

30x2x1,5

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,8

0,8

0,9

1,0

1,1

1,2

1,2

1,3

1,5

1,5

11,0

11,5

14,5

19,0

22,0

28,0

31,0

34,0

40,0

42,0

80

80

110

120

140

180

190

210

250

270

170

210

320

450

610

860

1030

1390

1800

2120

TVORNICA ELEKTRI^NIH KABELA ELECTRIC CABLE WORKS

Brodski i offshore kabeli Shipboard and offshore cables

19

KonstrukcijaConstruction

nxmm2

1

Nominalna debljinaizolacije

Nominal thickness ofinsulat.

mm

2

Nominalna debljinapla{ta

Nominal thickness ofsheath

m

3

m

Vanjski promjercca

External diameterapprox.

mm

4

Minimalni radiussavijanja

Minimal bendingradius

mm

5

Te`ina kabela ccaCable weight

approx.

kg/km

6

KonstrukcijaConstruction

nxmm2

1

Nominalna debljinaizolacije

Nominal thickness ofinsulat

mm

2

Nominalna debljinapla{ta

Nominal thickness ofsheath

mm

3

Vanjski promjercca

External diameterapprox.

mm

4

Minimalni radiussavijanja

Minimal bendingradius

mm

5

Te`ina kabela ccaCable weight

approx.

kg/km

6

E L K A d . d . , @ i t n j a k b . b . , H R - 1 0 0 0 0 Z A G R E B , C R O A T I A , T e l . : ( 0 1 ) 2 4 8 2 6 0 0 , F a x . : ( 0 1 ) 2 4 0 4 8 9 8

Page 22: 11 (Brodski i Offshor Kablovi)

3.8 NEARMIRANI, VATROOTPORNI KABELBEZ HALOGENA 0,6/1 kV

Konstrukcija i ispitivanje premastandarduMalcsimalna radna temperatura vodi~aNominalni naponIspitni naponIspitivanje zapaljivosti

lspitivanje na korozijuIspitivanje gusto}e dima

IEC 92-350, IEC 92-353

85 C

0,6/1 kV

3,5 kV

IEC 331, IEC 332-1,IEC 332-3/kat. A

IEC 754-1

IEC 61034

600 600

60 6060

60

0

. . . . . ...................... . . .

. . . . . . .

. . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . .

. . . ...... . .

. . . . . . . . . . . . . .

. . . . . . . . . . . .

OPIS KONSTRUKCIJE1. Vodi~:

2. Separator:3. Izolacija:4. Ispuna:5. Pla{t:

ELKA CS ATOX-MARIN BXO-HFVO 331 nxS mm0,6/1 kV IEC 92-353, IEC 332-3A

Boje izolacije:Jedno`ilni:Dvo`ilni:

Sedmero i vi{e`ilni:Boja pla{ta:

pokositrena bakrena `ica, klasa 2, IEC 228,(50 mm do 300 mm okruglog ili sektorskogoblika) Vidi tablicu 13

mica traka

XLPE, prema IEC 92-351

smjesa na bazi poliolefina

poliolefin, tip SHF 1 prema IEC 92-359(SHF 2 na zahtjev)

crna ili siva

crna, plava

bijela ili crna s brojevima 1 ... n

crna ili siva

60

600

600

2 2

OZNAKA NA PLA[TU2

600 60

Tro`ilni:^etvero`ilni:Petero`ilni:

crna, plava, sme|a (ili zeleno/`uta)

crna, plava, sme|a, bijela (ili zeleno/`uta)

crna, crna, plava, sme|a, bijela (ili zeleno/`uta)

3.8 UNARMOURED,

HALOGEN FREE CABLE 0,6/1 kV

FIRE RESISTANT,

Construction and testing

standards

Maximum operating temperature of conductor

Nominal voltage

Testing voltage

Inflammability test

Corrosi test

Smoke density test

according to

on

IEC 92-350, IEC 92-353

85 C

0,6/1 kV

3,5 kV

IEC 331, IEC 332-1,

IEC 332-3/cat.A

IEC 754-1

IEC 1034

600 600

60 60

60

60

6

0

. . . . . . . . . . . . .

. . . .

. . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . .

. . . . . . . . . .

. . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . .

.............

CONSTRUCTION DESCRIPTION1. Conductor:

2. Separator:

3. Insulation:

4. Filler:

5. Sheath:

ELKA CS ATOX-MARIN BXO-HFVO nxS mm

0,6/1 kV IEC 92-353, IEC 332-3A

Insulation colours:

Single-core:

Two-cores:

Seven- and multicore:

Sheath colour:

tinned copper wire, class 2, IEC 228

(50 mm up to 300 mm round or sector-

shaped) See Table 13

mica tape

XLPE, acc. to IEC 92-351

compound on the polyolefine basis

polyolefine, type SHF 1 acc. to IEC 92-359

(SHF 2 on request)

black or gray

black, blue

white or black with numbers 1 ... n

black or gray

60

600

600

2 2

SHEATH MARKING2

600 60

Three-cores:

Four-cores:

Five-cores:

black, blue, brown (or gr/ye)

black, blue, brown, white (or gr/ye)

black, black, blue, brown, white (or gr/ye)

12345

TVORNICA ELEKTRI^NIH KABELA ELECTRIC CABLE WORKS

Brodski i offshore kabeli Shipboard and offshore cables

20

BXO-HFVO

E L K A d . d . , @ i t n j a k b . b . , H R - 1 0 0 0 0 Z A G R E B , C R O A T I A , T e l . : ( 0 1 ) 2 4 8 2 6 0 0 , F a x . : ( 0 1 ) 2 4 0 4 8 9 8

Page 23: 11 (Brodski i Offshor Kablovi)

Table 14. BXO-HFVO 0,6/1 kVConstruction data of cableTablica 14. BXO-HFVO 0,6/1 kVKonstrukcijski podaci za kabel

1x1,5

1x2,5

1x4

1x6

1x10

1x16

1x25

1x351x50

1x70

1x95

1x120

1x150

1x185

1x240

1x300

2x1

2x1,5

2x2,5

2x4

2x6

2x10

2x16

2x25

2x35

2x50

2x70

2x95

2x120

2x150

2x185

2x240

2x300

3x1

3x1,5

3x2,5

3x4

3x6

3x10

3x16

3x25

3x35

3x50

3x70

3x95

3x120

3x150

3x185

3x240

3x300

0,7

0,7

0,7

0,7

0,7

0,7

0,9

0,9

1,0

1,1

1,1

1,2

1,4

1,6

1,7

1,8

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,9

0,9

1,0

1,1

1,1

1,2

1,4

1,6

1,7

1,8

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,9

0,9

1,0

1,1

1,1

1,2

1,4

1,6

1,7

1,8

1,0

1,0

1,0

1,0

1,0

1,1

1,1

1,2

1,2

1,3

1,4

1,5

1,5

1,6

1,7

1,8

1,1

1,1

1,1

1,1

1,2

1,2

1,3

1,4

1,5

1,6

1,8

1,9

2,1

2,2

2,3

2,5

2,7

1,1

1,1

1,1

1,1

1,2

1,2

1,4

1,5

1,6

1,6

1,7

1,8

2,0

2,1

2,2

2,3

2,6

5,5

6,0

6,5

7,0

8,0

9,5

11,0

12,5

14,0

16,0

18,0

20,0

22,5

24,5

28,0

30,5

9,0

10,0

11,0

12,0

13,0

15,0

17,5

21,0

23,5

26,0

31,0

35,0

39,0

43,0

47,5

54,0

60,0

10,0

10,5

11,5

12,5

14,0

16,0

19,0

22,5

25,0

S 24,0 28,0

S 27,0 32,0

S 30,0 36,0

S 34,0 40,0

S 38,0 44,0

S 42,0 49,0

S 47,0 54,0

S 54,0 62,0

35

40

45

45

55

60

70

80

90

100

120

130

150

160

180

200

60

65

70

80

85

100

110

140

150

170

200

230

250

280

300

350

390

65

70

75

80

90

100

120

150

160

160

180

190

220

250

280

310

350

50

60

80

100

140

210

310

420

560

780

1050

1300

1600

2000

2500

3100

110

130

160

210

280

390

580

870

1150

1200

1670

2200

2750

3400

4200

5300

6550

125

150

190

260

340

500

740

1110

1450

1800

2550

3400

4250

5300

6500

8300

10300

20

28

38

48

67

90

120

145

153

225

275

320

365

415

490

560

14

17

24

32

41

57

77

102

123

153

191

234

272

310

353

417

476

11

14

20

27

34

47

63

84

102

126

158

193

224

256

291

343

392

TVORNICA ELEKTRI^NIH KABELA ELECTRIC CABLE WORKS

Brodski i offshore kabeli Shipboard and offshore cables

21

KonstrukcijaConstruction

nxmm2

1

Nominalna debljinaizolacije

Nominal thickness ofinsulat.

mm

2

Nominalna debljinapla{ta

Nominal thickness ofsheath

mm

3

Vanjski promjer ccaExternal diameter

approx.

mm

4

Minimalni radiussavijanja

Minimal bendingradius

mm

5

Te`ina kabela ccaCable weight

approx.

kg/km

6

Strujnooptere}enjeCurrent load

A

7

E L K A d . d . , @ i t n j a k b . b . , H R - 1 0 0 0 0 Z A G R E B , C R O A T I A , T e l . : ( 0 1 ) 2 4 8 2 6 0 0 , F a x . : ( 0 1 ) 2 4 0 4 8 9 8

Page 24: 11 (Brodski i Offshor Kablovi)

Table 14. ContinuedTablica 14. Nastavak

7654321

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,9

0,9

1,0

1,1

1,1

1,2

1,4

1,6

1,7

1,8

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

4x1

4x1,5

4x2,5

4x4

4x6

4x10

4x16

4x25

4x35

4x50

4x70

4x95

4x120

4x150

4x185

4x240

4x300

5x1

7x1

10x1

12x1

14x1

16x1

19x1

24x1

27x1

30x1

37x1

48x1

61x1

5x1,5

7x1,5

10x1,5

12x1,5

14x1,5

16x1,5

19x1,5

24x1,5

27x1,5

30x1,5

37x1,5

48x1,5

61x1,5

5x2,5

7x2,5

10x2,5

12x2,5

14x2,5

16x2,5

19x2,5

24x2,5

27x2,5

30x2,5

37x2,5

48x2,5

61x2,5

1,1

1,1

1,2

1,2

1,2

1,3

1,4

1,6

1,7

1,8

2,0

2,1

2,2

2,4

2,6

2,8

2,9

1,1

1,1

1,2

1,2

1,2

1,3

1,3

1,4

1,4

1,4

1,5

1,6

1,7

1,1

1,1

1,3

1,3

1,3

1,3

1,4

1,5

1,5

1,5

1,6

1,7

1,8

1,1

1,2

1,3

1,3

1,4

1,4

1,4

1,6

1,6

1,6

1,7

1,8

2,0

11,0

11,5

12,5

14,0

15,5

17,5

20,5

25,0

28,0

S 29,0 33,0

S 34,0 40,0

S 38,0 44,0

S 41,0 46,0

S 46,0 52,0

S 50,0 57,0

S 56,0 63,0

S 60,0 68,0

11,5

12,5

16,0

16,5

17,0

18,5

19,0

22,5

23,0

24,0

26,0

30,0

33,0

12,5

13,5

17,0

18,0

19,0

20,0

21,0

25,0

25,5

26,5

28,5

33,0

36,0

13,5

15,0

19,0

20,0

21,0

22,0

23,0

27,5

28,0

29,0

31,5

36,0

40,0

70

75

80

90

100

110

130

160

180

190

220

250

260

290

320

350

380

75

80

100

105

110

120

125

145

150

160

170

190

210

80

90

110

120

125

130

140

160

165

170

180

210

230

90

100

120

130

135

140

150

170

180

190

200

230

260

145

180

240

320

420

620

1020

1390

1850

2450

3400

4500

5600

7050

860011000

13500

175

220

300

345

390

450

510

650

700

760

910

1170

1430

220

280

390

440

510

560

670

800

890

970

1180

1500

1850

290

370

505

590

670

760

870

1100

1200

1300

1600

2000

2500

11

14

20

27

34

47

63

84

102

126

158

193

224

256

291

343

392

11

8

7

6

6

6

6

5

5

4

4

3

3

14

10

9

8

8

7

7

6

6

5

5

4

4

20

14

13

11

10

10

9

8

7

7

6

6

5

TVORNICA ELEKTRI^NIH KABELA ELECTRIC CABLE WORKS

Brodski i offshore kabeli Shipboard and offshore cables

22E L K A d . d . , @ i t n j a k b . b . , H R - 1 0 0 0 0 Z A G R E B , C R O A T I A , T e l . : ( 0 1 ) 2 4 8 2 6 0 0 , F a x . : ( 0 1 ) 2 4 0 4 8 9 8

Page 25: 11 (Brodski i Offshor Kablovi)

3.9 ARMIRANI, VATROOTPORNI KABELBEZ HALOGENA 0,6/1 kV

Konstrukcija i ispitivanje premastandarduMaksimalna radna temperatura vodi~aNominalni naponIspitni naponIspitivanje zapaljivosti

Ispitivanje na korozijuIspitivanje gusto}e dima

IEC 92-350, IEC 92-353

85 C

0,6/1 kV

3,5 kV

IEC 331, IEC 332-1,IEC 332-3/kat. A

IEC 754-1

IEC 1034

600 600

60 6060

60

6

0

. . . . . . . . . .

. . . . . .

. . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . .

. . .

. . . . . . . . . . . . .

. . . . . . . . . . . .

OPIS KONSTRUKCIJE1. Vodi~:

2. Separator:3. Izolacija:4. Ispuna i unutra{nji

pla{t:5. Ekran:

6. Pla{t:

ELKA CS ATOX-MARIN BXOZO-HFVO nxS mm0,6/1 kV IEC 92-353, IEC 332-3A

Boje izolacije:Jedno`ilni:Dvo`ilni:

Sedmero i vi{e`ilni:Boja pla{ta:

pokositrena bakrena `ica, klasa 2, IEC 228,(50 mm do 300 mm okruglog ili sektorskogoblika) Vidi tablicu 13

mica traka

XLPE, prema IEC 92-351

smjesa na bazi poliolefina

oplet od pokositrenih bakrenih `ica(minimalna gusto}a 90%)poliolefin, tip SHF 1 prema IEC 92-359(SHF 2 na zahtjev)

crna ili siva

crna, plava

bijela ili crna s brojevima 1 ... n

crna ili siva

60

600

2 2

600

crna, plava, sme|a (ili zeleno/`uta)

crna, plava, sme|a, bijela (ili zeleno/`uta)

crna, crna, plava, sme|a, bijela (ili zeleno/`uta)

OZNAKA NA PLA[TU2

600

Tro`ilni:^etvero`ilni:Petero`ilni:

60

3.9 ARMOURED, FIRE RESISTANT,

CABLE 0,6/1 kVHALOGEN FREE

Construction and testing

standard

Maximum operating temperature of conductor

Nominal voltage

Testing voltage

Inflammability test

Corrosi test

Smoke density test

according to

on

IEC 92-350, IEC 92-353

85 C

0,6/1 kV

3,5 kV

IEC 331, IEC 332-1,

IEC 332-3/cat.A

IEC 754-1

IEC 1034

600 600

60 60

60

60

6

0

. . . . . . . . . .

.. . .

. . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . .

. . .

. . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . .

.............

CONSTRUCTION DESCRIPTION1. Conductor:

2. Separator:

3. Insulation:

4. Filler and inner

covering:

5. Screen:

6. Sheath:

ELKA CS ATOX-MARIN BXO-HFVO nxS mm

0,6/1 kV IEC 92-353, IEC 332-3A

Insulation colours:

Single-core:

Two-cores:

Seven- and multicore:

Sheath colour:

tined copper wire, class 2, IEC 228

(50 mm up to 300 mm round or sector-

shaped) See Table 13

mica tape

XLPE, acc. to IEC 92-351

compound on the polyolefine basis

tinned copper wires braiding

polyolefine, type SHF 1 acc. to IEC 92-359

(SHF 2 on request)

black or gray

black, blue

white or black with numbers 1 ... n

black or gray

60

600

600

2 2

SHEATH MARKING2

600 60

Three-cores:

Four-cores:

Five-cores:

black, blue, brown (or gr/ye)

black, blue, brown, white (or gr/ye)

black, black, blue, brown, white (or gr/ye)

123456

TVORNICA ELEKTRI^NIH KABELA ELECTRIC CABLE WORKS

Brodski i offshore kabeli Shipboard and offshore cables

23

BXOZO-HFVO

E L K A d . d . , @ i t n j a k b . b . , H R - 1 0 0 0 0 Z A G R E B , C R O A T I A , T e l . : ( 0 1 ) 2 4 8 2 6 0 0 , F a x . : ( 0 1 ) 2 4 0 4 8 9 8

Page 26: 11 (Brodski i Offshor Kablovi)

Table 15. BXOZO-HFVO 0,6/1 kVConstruction data of cableTablica 15. BXOZO-HFVO 0,6/1 kVKonstrukcijski podaci za kabel

1x1,5

1x2,5

1x4

1x6

1x10

1x16

1x25

1x351x50

1x70

1x95

1x120

1x150

1x185

1x240

1x300

2x1

2x1,5

2x2,5

2x4

2x6

2x10

2x16

2x25

2x35

2x50

2x70

2x95

2x120

2x150

2x185

2x240

2x300

3x1

3x1,5

3x2,5

3x4

3x6

3x10

3x16

3x25

3x35

3x50

3x70

3x95

3x120

3x150

3x185

3x240

3x300

0,7

0,7

0,7

0,7

0,7

0,7

0,9

0,9

1,0

1,1

1,1

1,2

1,4

1,6

1,7

1,8

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,9

0,9

1,0

1,1

1,1

1,2

1,4

1,6

1,7

1,8

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,9

0,9

1,0

1,1

1,1

1,2

1,4

1,6

1,7

1,8

1,0

1,0

1,1

1,1

1,1

1,2

1,2

1,3

1,3

1,4

1,5

1,5

1,6

1,7

1,8

1,9

1,1

1,1

1,2

1,2

1,3

1,3

1,4

1,5

1,6

1,7

1,9

2,0

2,2

2,3

2,5

2,7

2,9

1,1

1,2

1,2

1,2

1,3

1,4

1,5

1,6

1,7

1,7

1,8

1,9

2,1

2,2

2,4

2,5

2,8

8,5

9,0

9,5

10,0

11,0

12,5

14,0

16,0

17,5

20,0

22,0

24,0

26,0

28,0

31,0

34,0

12,0

13,0

14,0

15,0

17,0

19,0

21,0

25,0

27,0

30,0

34,0

39,0

43,0

48,0

53,0

59,0

65,0

12,5

13,5

14,5

16,0

18,0

20,0

22,0

26,0

29,0

S 28,0 32,0

S 30,0 36,0

S 34,0 40,0

S 39,0 45,0

S 42,0 49,0

S 47,0 54,0

S 50,0 58,0

S 57,0 65,0

50

55

60

65

70

80

90

95

110

120

140

150

160

180

190

210

75

80

85

90

100

120

130

160

170

190

210

250

270

300

330

380

410

80

85

90

100

110

120

140

160

180

175

190

210

240

270

290

320

360

110

125

155

190

245

320

435

590

760

1000

1280

1560

1950

2270

2880

3490

170

230

280

350

470

620

810

1150

1450

1930

2570

3360

4240

5130

6310

7940

9650

220

260

325

430

495

720

985

1400

1810

2150

2950

3900

4800

5950

7200

9150

11200

20

28

38

48

67

90

120

145

180

225

275

320

365

415

490

560

14

17

24

32

41

57

77

102

123

153

191

234

272

310

353

417

476

11

14

20

27

34

47

63

84

102

126

158

193

224

256

291

343

392

TVORNICA ELEKTRI^NIH KABELA ELECTRIC CABLE WORKS

Brodski i offshore kabeli Shipboard and offshore cables

24

KonstrukcijaConstruction

nxmm2

1

Nominalna debljinaizolacije

Nominal thickness ofinsulat.

mm

2

Nominalna debljinapla{ta

Nominal thickness ofsheath

mm

3

Vanjski promjer ccaExternal diameter

approx.

mm

4

Minimalni radiussavijanja

Minimal bendingradius

mm

5

Te`ina kabela ccaCable weight

approx.

kg/km

6

Strujnooptere}enjeCurrent load

A

7

E L K A d . d . , @ i t n j a k b . b . , H R - 1 0 0 0 0 Z A G R E B , C R O A T I A , T e l . : ( 0 1 ) 2 4 8 2 6 0 0 , F a x . : ( 0 1 ) 2 4 0 4 8 9 8

Page 27: 11 (Brodski i Offshor Kablovi)

Table 15. ContinuedTablica 15. Nastavak

7654321

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,9

0,9

1,0

1,1

1,1

1,2

1,4

1,6

1,7

1,8

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

4x1

4x1,5

4x2,5

4x4

4x6

4x10

4x16

4x25

4x35

4x50

4x70

4x95

4x120

4x150

4x185

4x240

4x300

5x1

7x1

10x1

12x1

14x1

16x1

19x1

24x1

27x1

30x1

37x1

48x1

61x1

5x1,5

7x1,5

10x1,5

12x1,5

14x1,5

16x1,5

19x1,5

24x1,5

27x1,5

30x1,5

37x1,5

48x1,5

61x1,5

5x2,5

7x2,5

10x2,5

12x2,5

14x2,5

16x2,5

19x2,5

24x2,5

27x2,5

30x2,5

37x2,5

48x2,5

61x2,5

1,2

1,2

1,2

1,3

1,3

1,4

1,5

1,7

1,8

1,9

2,1

2,2

2,3

2,5

2,7

2,9

3,1

1,2

1,2

1,3

1,4

1,4

1,4

1,4

1,5

1,6

1,6

1,6

1,8

1,8

1,2

1,3

1,4

1,4

1,4

1,5

1,5

1,6

1,6

1,6

1,7

1,9

2,0

1,3

1,3

1,5

1,5

1,5

1,5

1,6

1,7

1,7

1,8

1,8

2,0

2,1

85

90

100

110

120

140

150

180

190

200

240

270

290

320

350

380

420

80

85

100

110

120

120

130

140

150

155

160

185

200

100

110

130

140

140

145

150

170

180

190

200

230

250

100

110

140

140

150

160

170

190

200

210

220

250

280

13,5

14,5

16,0

17,5

19,0

22,0

24,0

29,0

31,0

S 32,0 36,0

S 38,0 44,0

S 42,0 49,0

S 45,0 52,0

S 50,0 57,0

S 55,0 62,0

S 61,0 69,0

S 66,0 74,0

14,0

15,0

18,5

20,0

20,5

21,5

23,0

26,0

27,0

28,0

29,0

33,0

36,0

16,0

17,0

21,0

22,0

22,5

24,0

25,0

28,0

29,0

30,0

32,0

37,0

40,0

17,0

18,5

22,5

23,5

24,0

26,0

27,0

31,0

31,5

33,0

35,0

41,0

45,0

255

310

335

520

655

880

1230

1750

2280

2850

4000

5350

6350

7900

955012200

14900

240

305

420

465

510

565

630

765

800

885

1020

1250

1500

360

465

610

670

740

810

910

1130

1200

1310

1560

1930

2450

480

585

745

830

925

1030

1180

1470

1570

1710

2030

2530

3190

11

14

20

27

34

47

63

84

102

126

158

193

224

256

291

343

392

11

8

7

6

6

6

6

5

5

4

4

3

3

14

10

9

8

8

7

7

6

6

5

5

4

4

20

14

13

11

10

10

9

8

7

7

6

6

5

TVORNICA ELEKTRI^NIH KABELA ELECTRIC CABLE WORKS

Brodski i offshore kabeli Shipboard and offshore cables

25E L K A d . d . , @ i t n j a k b . b . , H R - 1 0 0 0 0 Z A G R E B , C R O A T I A , T e l . : ( 0 1 ) 2 4 8 2 6 0 0 , F a x . : ( 0 1 ) 2 4 0 4 8 9 8

Page 28: 11 (Brodski i Offshor Kablovi)

3.10 TELEKOMUNIKACIJSKI, ARMIRANI,VATROOTPORNI KABEL BEZ HALOGENA,60 V - 250 V - 0,6/1 kV

Konstrukcija i ispitivanje premastandardu

Maksimalna radna temperatura vodi~aNominalni naponIspitni naponIspitivanje zapaljivosti

Ispitivunje na korozijuIspitivanje gusto}e dima

IEC 92-3, IEC 92-350,IEC 92-353, IEC 92-375

85 C

60 V 250 V 0,6/1 kV

1500 V 1500 V 3,5 kV

IEC 331, IEC 332-1,IEC 332-3/kat. A

IEC 754-1

IEC 61034

600 600600 600

60 6060

60

0

. . . . .

. . . . . . . .

. . . . . . . . . .

. . . . . . . . . . .

. . . . . . . .

. . . . . . . . . . . . .

. . . . . . . . . . . .

..

OPIS KONSTRUKCIJE1. Vodi~:

2. Separator:3. Izolacija:4. Separator:5. Ispuna i unutra{nji

pla{t:6. Armatura:

7. Pla{t:

ELKA CS ATOX-MARIN TBXOZO-HFVO 331 nxSmm60 V/250 V (ili 0,6/1 kV)IEC 92-3, IEC 92-375, IEC 332-3A(ili IEC 92-353, IEC 332-3A)

Boje izolacije:

Konstrukcija parica:

Boja pla{ta:

po sitrena bakrena `ica, klasa 2, IEC 228,Vidi tablicu 23

mica traka

XLPE, prema IEC 92-351

prema zahtjevu

smjesa na bazi poliolefina

oplet od pokositrenih bakrenih `ica(minimalna gusto}a 90%)

poliolefin, tip SHF 1 prema IEC 92-359(SHF 2 na zahtjev)

Bijela ili crna, s brojevima: 2 n

1-2; 3-4; 5-6

siva ili narand`asta

ko

1, ...

60

600

600

OZNAKA NA PLA[TU2

600 600 60600 60

.................................................

3.10 TELECOMMUNICATION, ARMOURED,

HALOGEN FREE,

60 V - 250 V - 0,6/1 kV CABLE

FIRE RESISTANT,

Construction and testing

standards

Maximum operating temperature of conductor

Nominal voltage

Testing voltage

Inflammability test

Corrosi test

Smoke density test

according to

on

IEC 92-3, IEC 92-350,

IEC 92-353, IEC 92-375

85 C

60 V 250 V 0,6/1 kV

1500 V 1500 V 3,5 kV

IEC 331, IEC 332-1,

IEC 332-3/cat.A

IEC 754-1

IEC 61034

600 600

600 600

60 60

60

60

0

. . . . . . . . . . . .

. .. .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . .

.............

CONSTRUCTION DESCRIPTION1. Conductor:

2. Separator:

3. Insulation:

4. Separator:

5. Filler and inner

sheath:

6. Armour:

7. Sheath:

ELKA CS ATOX-MARIN TBXOZO-HFVO 331 nxS mm 60

V/250 V (or 0,6/1 kV)

IEC 92-3, IEC 92-375, IEC 332-3A

(OR IEC 92-353, IEC 332-3A)

Insulation colours:

Pairs construction:

Sheath colour:

tinned copper wire, class 2, IEC 228

See Table 23

mica tape

XLPE, acc. to IEC 92-351

as required

compound on the polyolefine basis

tinned copper wires braiding

(minimum density 90%)

polyolefine, type SHF 1 acc. to IEC 92-359

(SHF2 on request)

White or black, numbered: 1, 2 n

1-2; 3-4; 5-6

gray or orange

60

600

600

SHEATH MARKING2

600 60

600 60

.................................................

4567

3 2 1

TVORNICA ELEKTRI^NIH KABELA ELECTRIC CABLE WORKS

Brodski i offshore kabeli Shipboard and offshore cables

26

TBXOZO-HFVO

E L K A d . d . , @ i t n j a k b . b . , H R - 1 0 0 0 0 Z A G R E B , C R O A T I A , T e l . : ( 0 1 ) 2 4 8 2 6 0 0 , F a x . : ( 0 1 ) 2 4 0 4 8 9 8

Page 29: 11 (Brodski i Offshor Kablovi)

3.11 TELEKOMUNIKACIJSKI, ARMIRANI,VATROOTPORNI KABEL BEZ HALOGENA,SA ZAJEDNI^KIM EKRANOM60 V - 250 V - 0,6/1 kV

Konstrukcija i ispitivanje premastandardu

Maksimalna radna temperatura vodi~aNominalni naponIspitni naponIspitivanje zapaljivosti

Ispitivanje na korozijuIspitivanje gusto}e dima

IEC 92-3, IEC 92-350,IEC 92-353, IEC 92-375

85 C60 V 250 V 0,6/1 kV

1500 V 1500 V 3,5 kVIEC 331, IEC 332-1,

IEC 332-3/kat. AIEC 754-1

IEC 1034

600 600600 600

60 6060

606

0

. . . . . . . . . .

. . . . . . . .. . . . . . . . . .

. . . . . . . . . . .. . . . . .

. . . . . . . . . . . . .. . . . . . . . . . . .

OPIS KONSTRUKCIJE1. Vodi~:

2. Separator:3. Izolacija:4. Separator:5. Zajedni~ki ekran:

6. Ispuna i unutra{njipla{t:

7. Armatura:

8. Pla{t:

ELKA CS ATOX-MARIN TBX(Z1)OZO-HFVO 331nxS mm 60 V/250 V (ili 0,6/1 kV)IEC 92-3, IEC 92-375, IEC 332-3A(ili IEC 92-353, IEC 332-3A)

Boje izolacije:

Konstrukcija parica:

Boja pla{ta:

pokositrena bakrena `ica, klasa 2, IEC 228,Vidi tablicu 13

mica traka

XLPE, prema IEC 92-351

prema zahtjevu

metalizirana poliesterskatraka s odvodnom `icom

smjesa na bazi poliolefina

oplet od pokositrenih bakrenih `ica(minimalna gusto}a 90%)

poliolefin, tip SHF 1 prema IEC 92-359(SHF 2 na zahtjev)

Bijela ili crna, s brojevima: 1, 2 n

1-2; 3-4; 5-6

siva ili narand`asta

60

600

600

OZNAKA NA PLA[TU

2

600 600 60600 60

...

3.11 TELECOMMUNICATION, ARMOURED,WITH COMMON SCREEN,HALOGEN FREE CABLE60 V - 250 V - 0,6/1 kV

FIRE RESISTANT,

Construction and testingstandard

Maximum operating temperature of conductor

Nominal voltage

Testing voltage

Inflammability test

Corrosi test

Smoke density test

according to

on

IEC 92-3, IEC 92-350,IEC 92-353, IEC 92-375

85 C60 V 250 V 0,6/1 kV1500 V 1500 V 3,5 kV

IEC 331, IEC 332-1,IEC 332-3/cat.A

IEC 754-1IEC 1034

600

60606

600600 600

60 60

0

. . . . . . . . . . . . . . .

. . . . . .. . . . . . . . . .

. . . . . . . . . .. . . . . . . . .

. . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .

........

.

..

CONSTRUCTION DESCRIPTION1. Conductor:

2. Separator:

3. Insulation:

4. Separator:

5. Common screen:

6. Filler and inner

covering:

7. Armour:

8. Sheath:

ELKA CS ATOX-MARIN TBX(Z1)OZO-HFVO 331

nxS mm 60 V/250 V (or 0,6/1 kV)

IEC 92-3, IEC 92-375, IEC 332-3A

(or IEC 92-353, IEC 332-3A)

Insulation colours:

Pairs construction:

Sheath colour:

tinned copper wire, class 2, IEC 228See Table 13

mica tape

XLPE, acc. to IEC 92-351

as required

metalized polyester tapewith drain wire

compound on the polyolefine basis

tinned copper wires braiding(minimum density 90%)

polyolefine, type SHF 1 acc. to IEC 92-359(SHF 2 on request)

White or black, numbered: 1, 2 n

1-2; 3-4; 5-6

gray or orange

60

600

600

SHEATH MARKING

2

600 600 60

600 60

...

45678

TVORNICA ELEKTRI^NIH KABELA ELECTRIC CABLE WORKS

Brodski i offshore kabeli Shipboard and offshore cables

27

TBX(Z1)OZO-HFVO

3 2 1

E L K A d . d . , @ i t n j a k b . b . , H R - 1 0 0 0 0 Z A G R E B , C R O A T I A , T e l . : ( 0 1 ) 2 4 8 2 6 0 0 , F a x . : ( 0 1 ) 2 4 0 4 8 9 8

Page 30: 11 (Brodski i Offshor Kablovi)

Table 16. TBXOZO-HFVO

TBX(Z1)OZO-HFVO 60/250 V

Construction data of and

cable

Tablica 16.TBXOZO-HFVO TBX(Z1)OZO-HFVO 60/250 VKonstrukcijski podaci za kabel

i

1x2x0,50

1x3x0,50

2x2x0,50

4x2x0,50

7x2x0,50

10x2x0,50

14x2x0,50

19x2x0,50

24x2x0,50

30x2x0,50

0,5

0,5

0,5

0,5

0,5

0,5

0,5

0,5

0,5

0,5

1,1

1,1

1,1

1,2

1,2

1,3

1,3

1,4

1,4

1,5

10,0

10,5

12,0

15,0

18,0

22,0

24,0

26,0

31,0

33,0

70

70

70

95

120

140

160

170

200

210

140

170

205

280

405

530

630

795

950

1100

Tablica 17.TBXOZO-HFVO TBX(Z1)OZO-HFVO 60/250 VKonstrukcijski podaci za kabel

iTable 17. TBXOZO-HFVO

TBX(Z1)OZO-HFVO 60/250 V

Construction data of and

cable

1x2x0,75

1x3x0,75

2x2x0,75

4x2x0,75

7x2x0,75

10x2x0,75

14x2x0,75

19x2x0,75

24x2x0,75

30x2x0,75

0,6

0,6

0,6

0,6

0,6

0,6

0,6

0,6

0,6

0,6

1,1

1,1

1,1

1,2

1,3

1,3

1,4

1,5

1,5

1,6

10,5

11,0

13,0

17,0

20,0

25,0

27,0

30,0

35,0

37,5

70

75

90

110

130

160

170

190

220

250

160

200

250

350

490

670

800

1000

1240

1430

TVORNICA ELEKTRI^NIH KABELA ELECTRIC CABLE WORKS

Brodski i offshore kabeli Shipboard and offshore cables

28

KonstrukcijaConstruction

nxmm2

1

Nominalna debljinaizolacije

Nominal thickness ofinsulat

mm

2

Nominalna debljinapla{ta

Nominal thickness ofsheath

mm

3

Vanjski promjercca

External diameterapprox.

mm

4

Minimalni radiussavijanja

Minimal bendingradius

mm

5

Te`ina kabela ccaCable weight

approx.

kg/km

6

KonstrukcijaConstruction

nxmm2

1

Nominalna debljinaizolacije

Nominal thickness ofinsulat.

mm

2

Nominalna debljinapla{ta

Nominal thickness ofsheath

mm

3

Vanjski promjercca

External diameterapprox.

mm

4

Minimalni radiussavijanja

Minimal bendingradius

mm

5

Te`ina kabela ccaCable weight

approx.

kg/km

6

E L K A d . d . , @ i t n j a k b . b . , H R - 1 0 0 0 0 Z A G R E B , C R O A T I A , T e l . : ( 0 1 ) 2 4 8 2 6 0 0 , F a x . : ( 0 1 ) 2 4 0 4 8 9 8

Page 31: 11 (Brodski i Offshor Kablovi)

Table 18. TBXOZO-HFVO

TBX(Z1)OZO-HFVO 0,6/1 kV

Construction data of and

cable

Tablica 18.TBXOZO-HFVO TBX(Z1)OZO-HFVO 0,6/1 kVKonstrukcijski podaci za kabel

i

1x2x1

1x3x1

2x2x1

4x2x1

7x2x1

10x2x1

14x2x1

19x2x1

24x2x1

30x2x1

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,8

0,8

0,8

0,9

1,0

1,1

1,2

1,2

1,4

1,4

11,5

12,0

14,0

18,0

22,0

28,0

31,0

34,0

40,0

42,0

80

80

90

120

140

170

200

210

250

270

190

210

240

440

610

840

1040

1290

1650

1930

Tablica 19.TBXOZO-HFVO TBX(Z)OZO-HFTG 0,6/1 kVKonstrukcijski podaci za kabel

iTable 19. TBXOZO-HFVO

TBX(Z1)OZO-HFTG 0,6/1 kV

Construction data of and

cable

1x2x1,5

1x3x1,5

2x2x1,5

4x2x1,5

7x2x1,5

10x2x1,5

14x2x1,5

19x2x1,5

24x2x1,5

30x2x1,5

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,8

0,8

0,9

1,0

1,1

1,2

1,2

1,3

1,5

1,5

12,0

12,5

16,0

20,0

24,0

31,0

33,0

37,0

44,0

47,0

80

80

100

130

150

190

200

230

280

290

190

240

360

500

730

1030

1250

1570

2100

2470

TVORNICA ELEKTRI^NIH KABELA ELECTRIC CABLE WORKS

Brodski i offshore kabeli Shipboard and offshore cables

29

KonstrukcijaConstruction

nxmm2

1

Nominalna debljinaizolacije

Nominal thickness ofinsulat

mm

2

Nominalna debljinapla{ta

Nominal thickness ofsheath

mm

3

Vanjski promjercca

External diameterapprox.

mm

4

Minimalni radiussavijanja

Minimal bendingradius

mm

5

Te`ina kabela ccaCable weight

approx.

kg/km

6

KonstrukcijaConstruction

nxmm2

1

Nominalna debljinaizolacije

Nominal thickness ofinsulat.

mm

2

Nominalna debljinapla{ta

Nominal thickness ofsheath

mm

3

Vanjski promjercca

External diameterapprox.

mm

4

Minimalni radiussavijanja

Minimal bendingradius

mm

5

Te`ina kabela ccaCable weight

approx.

kg/km

6

E L K A d . d . , @ i t n j a k b . b . , H R - 1 0 0 0 0 Z A G R E B , C R O A T I A , T e l . : ( 0 1 ) 2 4 8 2 6 0 0 , F a x . : ( 0 1 ) 2 4 0 4 8 9 8

Page 32: 11 (Brodski i Offshor Kablovi)

3.12 TELEKOMUNIKACIJSKI, ARMIRANIVATROOTPORNI KABEL BEZ HALOGENAS INDIVIDUALNIM I ZAJEDNI^KIMEKRANOM 60 V - 250 V - 0,6/1 Kv

Konstrukcija i ispitivanje premastandardu

Maksimalna radna temperatura vodi~aNominalni naponIspitni naponIspitivanje zapaljivosti

Ispitivanje na korozijuIspitivanje gusto}e dima

IEC 92-3, IEC 92-350,IEC 92-353, IEC 92-375

85 C

60 V 250 V 0,6/1 kV

1500 V 1500 V 3,5 kV

IEC 331, IEC 332-1,IEC 332-3/kat.A

IEC 754-1

IEC 1034

600 600600 600

60 6060

60

6

0

. . . . . . .

. . . . . . . .

. . . . . . . . . .

. . . . . . . . . . .

. . . . . . .. . .

. . . . . . . . . . . .

. . . . . . . . . . . .

OPIS KONSTRUKCIJE1. Vodi~:

2. Separator:3. Izolacija:4. Ekran individualnih

parica:5. Separator:6. Zajedni~ki ekran:

7. Ispuna i unutra{njipla{t:

8. Ekran:

9. Pla{t:

ELKA CS ATOX-MARIN TBX(Z)OZO-HFVO 331nxS mm 60 V / 250 V (ili 0,6/1 kV)IEC 92-3, IEC 92-375, IEC 332-3A(ili IEC 92-353, IEC 332-31)

Boje izolacije:

Konstrukcija parica:

Boja pla{ta:

pokositrena bakrena `ica, klasa 2, IEC 228,Vidi tablicu 13

mica trakaXLPE, prema IEC 92-351

metalizirana poliesterska traka s odvodnom `icomprema zahtjevu

metalizirana poliesterska traka sodvodnom `icom

smjesa na bazi poliolefinaoplet od pokositrenih bakrenih `ica(minimalna gusto}a 90%)

poliolefin, tip SHF 1 prema IEC 92-359,(SHF2 na zahtjev)

Bijela ili crna, s brojevima: 1,

1-2; 3-4; 5-6

siva ili narand`asta

60

600

600

OZNAKA NA PLA[TU

2

600 600 60600 60

2 ... n

CONSTRUCTION DESCRIPTION1. Conductor:

2. Separator:

3. Insulation:

4. Individual pairscreen:

5. Separator:

6. Common screen:

7. Filler and innercovering:

8. Armour:

9. Sheath:

ELKA CS ATOX-MARIN TBX(Z)OZO-HFVO 331 nxS mm60 V / 250 V (or 0,6/1 kV)IEC 92-3, IEC 92-375, IEC 332-3A(or IEC 92-353, IEC 332-31)

Insulation colours:

Pairs construction:

Sheath colour:

tinned copper wire, class 2, IEC 228See Table 13mica tapeXLPE, acc. to IEC 92-351

metalized polyester tape with drain wireas requred

metalized poyester tapewith drain wire

compound on the polyolefine basistinned copper wires braiding(minimum density 90%)polyolefine type SHF 1 acc. to IEC 92-359(SHF2 on request)

White or black, numbered: 1, 2 n

1-2; 3-4; 5-6

gray or orange

60

600

600

SHEATH MARKING2

600 600 60600 60

...

1

456789

TVORNICA ELEKTRI^NIH KABELA ELECTRIC CABLE WORKS

Brodski i offshore kabeli Shipboard and offshore cables

30

TBX(Z)OZO-HFVO

3.12 TELECOMMUNICATION, ARMOURED,WITH INDIVIDUAL & COMMON SCREEN,

HALOGEN FREECABLE 60 V - 250 V - 0,6/1 kVFIRE RESISTANT,

Construction and testing

standards

Maximum operating temperature of conductor

Nominal voltage

Testing voltage

Inflammability test

Corrosi test

Smoke density test

according to

on

IEC 92-3, IEC 92-350,

IEC 92-353, IEC 92-375

85 C

60 V 250 V 0,6/1 kV

1500 V 1500 V 3,5 kV

IEC 331, IEC 332-1,

IEC 332-3/cat.A

IEC 754-1

IEC I034

600 600

600 600

60 60

60

60

6

0

. . . . . . . . . .

. .

. . . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . .

. . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . .

......

23

E L K A d . d . , @ i t n j a k b . b . , H R - 1 0 0 0 0 Z A G R E B , C R O A T I A , T e l . : ( 0 1 ) 2 4 8 2 6 0 0 , F a x . : ( 0 1 ) 2 4 0 4 8 9 8

Page 33: 11 (Brodski i Offshor Kablovi)

Tablica 20.TBX(Z)OZO-HFVO 60/250 VKonstrukcijski podaci za kabel Table 20.

TBX(Z)OZO-HFVO 60/250 V

Construction data of

cable

1x2x0,50

1x3x0,50

2x2x0,50

4x2x0,50

7x2x0,50

10x2x0,50

14x2x0,50

19x2x0,50

24x2x0,50

30x2x0,50

0,5

0,5

0,5

0,5

0,5

0,5

0,5

0,5

0,5

0,5

1,1

1,1

1,1

1,2

1,2

1,3

1,3

1,4

1,4

1,5

10,0

10,5

12,5

16,0

18,5

23,0

24,5

27,0

32,0

34,0

70

70

80

100

120

150

160

170

200

220

140

170

215

290

420

550

660

830

990

1150

Tablica 21.TBX(Z)OZO-HFVO 60/250 VKonstrukcijski podaci za kabel Table 21.

TBX(Z)OZO-HFVO 60/250 V

Construction data of

cable

1x2x0,75

1x3x0,75

2x2x0,75

4x2x0,75

7x2x0,75

10x2x0,75

14x2x0,75

19x2x0,75

24x2x0,75

30x2x0,75

0,6

0,6

0,6

0,6

0,6

0,6

0,6

0,6

0,6

0,6

1,1

1,1

1,1

1,2

1,3

1,3

1,4

1,5

1,5

1,6

10,5

11,0

13,5

18,0

21,0

26,0

28,0

31,0

36,5

39,0

70

75

85

110

130

170

180

200

230

250

160

200

250

350

500

690

800

1000

1240

1430

TVORNICA ELEKTRI^NIH KABELA ELECTRIC CABLE WORKS

Brodski i offshore kabeli Shipboard and offshore cables

31

KonstrukcijaConstruction

nxmm2

1

Nominalna debljinaizolacije

Nominal thickness ofinsulat

mm

2

Nominalna debljinapla{ta

Nominal thickness ofsheath

m

3

m

Vanjski promjercca

External diameterapprox.

mm

4

Minimalni radiussavijanja

Minimal bendingradius

mm

5

Te`ina kabela ccaCable weight

approx.

kg/km

6

KonstrukcijaConstruction

nxmm2

1

Nominalna debljinaizolacije

Nominal thickness ofinsulat.

mm

2

Nominalna debljinapla{ta

Nominal thickness ofsheath

mm

3

Vanjski promjercca

External diameterapprox.

mm

4

Minimalni radiussavijanja

Minimal bendingradius

mm

5

Te`ina kabela ccaCable weight

approx.

kg/km

6

E L K A d . d . , @ i t n j a k b . b . , H R - 1 0 0 0 0 Z A G R E B , C R O A T I A , T e l . : ( 0 1 ) 2 4 8 2 6 0 0 , F a x . : ( 0 1 ) 2 4 0 4 8 9 8

Page 34: 11 (Brodski i Offshor Kablovi)

Tablica 2 .TBX(Z1)OZO-HFVO 0,6/1 kV

2 Konstrukcijski podaci za kabel Table 2 .

TBX(Z1)OZO-HFVO 0,6/1 kV

2 Construction data of

cable

1x2x1

1x3x1

2x2x1

4x2x1

7x2x1

10x2x1

14x2x1

19x2x1

24x2x1

30x2x1

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,8

0,8

0,8

0,9

1,0

1,1

1,2

1,2

1,4

1,4

11,5

12,0

14,5

19,0

23,0

29,0

32,0

35,0

41,0

43,0

80

80

90

120

150

180

200

220

260

280

190

210

250

475

660

895

1090

1350

1720

2010

Tablica 23.TBX(Z1)OZO-HFVO 0,6/1 kVKonstrukcijski podaci za kabel Table 23.

TBX(Z1)OZO-HFVO 0,6/1 kV

Construction data of

cable

1x2x1,5

1x3x1,5

2x2x1,5

4x2x1,5

7x2x1,5

10x2x1,5

14x2x1,5

19x2x1,5

24x2x1,5

30x2x1,5

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,7

0,8

0,8

0,9

1,0

1,1

1,2

1,2

1,3

1,5

1,5

12,0

12,5

16,5

21,0

25,0

30,0

34,0

38,0

45,0

48,0

80

80

110

130

160

200

210

240

290

300

190

240

370

530

740

1050

1290

1620

2140

2510

TVORNICA ELEKTRI^NIH KABELA ELECTRIC CABLE WORKS

Brodski i offshore kabeli Shipboard and offshore cables

32

KonstrukcijaConstruction

nxmm2

1

Nominalna debljinaizolacije

Nominal thickness ofinsulat

mm

2

Nominalna debljinapla{ta

Nominal thickness ofsheath

mm

3

Vanjski promjercca

External diameterapprox.

mm

4

Minimalni radiussavijanja

Minimal bendingradius

mm

5

Te`ina kabela ccaCable weight

approx.

kg/km

6

KonstrukcijaConstruction

nxmm2

1

Nominalna debljinaizolacije

Nominal thickness ofinsulat.

mm

2

Nominalna debljinapla{ta

Nominal thickness ofsheath

mm

3

Vanjski promjercca

External diameterapprox.

mm

4

Minimalni radiussavijanja

Minimal bendingradius

mm

5

Te`ina kabela ccaCable weight

approx.

kg/km

6

E L K A d . d . , @ i t n j a k b . b . , H R - 1 0 0 0 0 Z A G R E B , C R O A T I A , T e l . : ( 0 1 ) 2 4 8 2 6 0 0 , F a x . : ( 0 1 ) 2 4 0 4 8 9 8

Page 35: 11 (Brodski i Offshor Kablovi)

4. ISPITIVANJA

Svi materijali, konstrukcije i ispitivanja energetskih itelekomunikacijskih brodskih kabela proizvedenih u ELKI, uskladu su sa slijede}im standardima:

Kabeli (konstrukcija, ispitivanje iacija).

Niskonaponski brodski energetski kabeli.Op}i zahtjevi u pogledu konstrukcije iispitivanja.

Izolacioni materijali brodskih energetskihkabela.

Izbor i instaliranje kabela za nisko-naponski energetski sistem.

Jedno- i vi{e`ilni neradijalni pobudnienergetski kabeli s ekstrudiranom~vrstom izolacijom za nazivne napone1 kV i 3 kV.

Jedno- i tro`ilni energetski kabeli sekstrudiranom ~vrstom izolacijom zanazivne napone 6 kV, 10 kV i 15 kV.

Pla{tevski materijali za brodske energetske i telekomunikacijske kabele.

Brodski telekomunikacijski kabeli i radiofrekvencijski kabeli.Op}i instrumentacijski, kontrolni i teleko-munikacijski kabeli.

Ispitivanje dimova nastalih tokom sagorijevanja elektri~nih kabela.Dio 1: Odre|ivanje koli~ine hologenogkiselog plina koji se razvija tokomsagorijevanja polimerskih materijalauzetih iz kabela.Mjerenje gusto}e dima nastalog pri gorenju

kabela pod odre|enim uvjetima.

Ispitivanje elektri~nih kabela pod djelovanjem vatre.Dio 1: Ispitivanje na okomito polo`enomizoliranom vodi~u ili kabelu.

Ispitivanje elektri~nih kabela pod djelova-njem vatre.Dio 3: Ispitivanje na usnopljenim vodovimai kabelima.

Vatrootporna svojstva elektri~nih kabela.

•IEC 60092-3:

•IEC 60092-350:

•IEC 60092-351:

•IEC 60092-352:

•IEC 60092-353:

•IEC 60092-354:

•IEC 60092-359:

•IEC 60092-375:

•IEC 60754-1:

IEC 61034:

•IEC 60332-1/93:

•IEC 60332-3/92:

•IEC 60331/70:

insta-l

Tehni~ka specifikacija zabrodske i offshore te{ko gori-ve i vatrootporne kabele bezhalogena s XLPE izolacijom.

, -

-

-

•ELKA TS-P-0220/228/1998IV/:

4. TESTS

IEC 60092-3:

IEC 60092-350:

IEC 60092-351:

IEC 60092-352:

IEC 60092-353: -

IEC 60092-354:

IEC 60092-359:

IEC 60092-375:

IEC 60754-1:

IEC 61034:

IEC 60332-1/93:

IEC 60332-3/92:

IEC 60331/70:

All materials, constructions and tests on the power and

telecommunication shipboard and off shore cables produced

of ELKA are according to next standards:

Cables (construction, testing and instal-lation).

Low voltage shipboard power cables.General construction and test requi-rements.

Insulating materials of shipboard powercables.

Choice and installation of cables for low-voltage power system.

Single and multicore non-radial field power cables with extruded solid insulationfor rated voltages 1 kV and 3 kV.

Single and three-core power cables withextruded solid insulation for ratedvoltages 6 kV, 10 kV and 15 kV.

Sheathing materials for shipboard powerand telecommunication cables.

Shipboard telecommunication cables andradio frequency cables.General instrumentation, control andtelecommunication cables.

Test on gases evolved during combustionof electric cables.Part 1: Determination of the amount ofhalogen acid gas evolved during thecombustion of polymeric materials takenfrom cables.

Measurement of smoke density of cablesburning under defined Conditions.

Tests on electrical cables under fireconditions.Part1: Test on a singl vertical insulated wireor cable.

Tests on electrical cables under fireconditions.Part 3: Test on bunched wires and cables.

Fire-resisting characteristics of electriccables.

•ELKA TS-P-0220/228/1998/IV: Technical specification forXLPE Insulation halogenfree fire retardant and fireresistant shipboard and off-shore cables.

TVORNICA ELEKTRI^NIH KABELA ELECTRIC CABLE WORKS

Brodski i offshore kabeli Shipboard and offshore cables

33E L K A d . d . , @ i t n j a k b . b . , H R - 1 0 0 0 0 Z A G R E B , C R O A T I A , T e l . : ( 0 1 ) 2 4 8 2 6 0 0 , F a x . : ( 0 1 ) 2 4 0 4 8 9 8

Page 36: 11 (Brodski i Offshor Kablovi)

5. TEHNI^KI PODACI

Tablica 24. Konstrukcijski podaci za vodi~

Tablica 25. Tolerancija vanjskog promjera kabela

5. TECHNICAL DATA

Table 24. Conductor construction data

Table 25. Tolerance of outher diameters of cable

Nominalnipresjek vodi~aNominal cross-

section of

conductors

Konstrukcija vodi~aConstruction of

conductor

PromjerDiameter

Sektorskog oblikaSector shaped

[irina x visina / Width x hight

Te`ina kabela ccaCable weight

approx.

0,50

0,75

1

1,5

2,5

4

6

10

16

25

35

50

70

95

120

150

185

240

300

7x0,31

7x0,37

7x0,43

7x0,53

7x0,67

7x0,85

7x1,04

7x1,35

7x1,70

7x2,13

7x2,52

19x1,78

19x2,13

19x2,51

37x2,02

37x2,85

37x2,51

61x2,25

61x2,51

0,9

1,1

1,3

1,6

2,0

2,5

3,1

3,7

4,6

5,8

6,8

8,0

9,6

11,3

12,7

14,1

15,7

18,0

23,8

-

-

-

-

-

-

-

-

-

-

-

12,0x7,0

14,5x8,0

17,5x9,5

18,0x11,0

21,0x12,2

23,0x13,5

26,6x14,9

29,5x17,7

-

-

-

-

-

-

-

-

-

-

-

11,8x8,2

13,2x10,0

15,2x11,5

17,6x12,5

19,8x14,0

22,3x15,6

25,4x17,5

28,5x19,2

41,6

26,6

18,2

12,2

7,56

4,70

3,11

1,84

1,16

0,734

0,529

0,391

0,270

0,195

0,154

0,126

0,100

0,0762

0,0607

mm2 n x mm mm mm mm Ohm/km

OkrugliRound

Nominalni vodi~Nominal conductor

3-`ilni / 3-core 4-`ilni /4-core

TVORNICA ELEKTRI^NIH KABELA ELECTRIC CABLE WORKS

Brodski i offshore kabeli Shipboard and offshore cables

34

Nazivni promjer / Nominal diametarmm

Tolerancija / Tolerance±mm

do 20

21 do 30

31 do 40

41 do 50

51 do 60

61 do 70

71 do 80

1,0

1,5

1,75

2,0

2,5

3,5

4,0

E L K A d . d . , @ i t n j a k b . b . , H R - 1 0 0 0 0 Z A G R E B , C R O A T I A , T e l . : ( 0 1 ) 2 4 8 2 6 0 0 , F a x . : ( 0 1 ) 2 4 0 4 8 9 8

CERTIFIKATI: TYPE APPROVALS:

Page 37: 11 (Brodski i Offshor Kablovi)

Rubber insulated conductors and cablesGumom izolirani vodovi i kabeli

TVORNICA ELEKTRI^NIH KABELA ELECTRIC CABLE WORKS

PROIZVODNI PROGRAM PRODUCT MIX

ENERGETSKI KABELI

SAVITLJIVI I INSTALACIJSKI VODOVI I KABELIIZOLIRANI TERMOPLASTIMA

SAVITLJIVI I INSTALACIJSKI VODOVI I KABELIIZOLIRANI ELASTOMERIMA

BRODSKI KABELI

KABELI I KONEKTORI ZA AERODROMSKEINSTALACIJE

TELEKOMUNIKACIJSKI KABELI

SVJETLOVODNI KABELI

SIGNALNO-UPRAVLJA^KI, MJERNI I KABELI ZAINFORMATI^KE MRE@E

RUDARSKI KABELI

KABELI ZA ZAVARIVANJE

SPECIJALNI VODOVI I KABELI

LAKIRANA @ICA

ALUMINIJSKA, ALU-^ELI^NA I U@AD ODALUMINIJSKIH LEGURA

ZA[TITNA U@AD SA SVJETLOVODNIM NITIMA (OPGW)

^ELI^NA U@AD I PRIVEZNICE ZA DIZALICE, BRODOVE IDRUGE NAMJENE

IZOLACIJSKI MATERIJALI

- 1 kV s PVC i XLPE izolacijom- 6 kV do 36 kV s XLPE i EPDM izolacijom- 1 kV do 36 kV s XLPE izolacijom u samonosivoj izvedbi

- energetski vodovi i kabeli- automobilski vodovi

- s EPDM izolacijom i CR pla{tom- te{ko gorivi, s izolacijom i pla{tom bez halogenih

- telefonski kabeli s PE izolacijom- telefonski kabeli s PVC izolacijom

- signalno-upravlja~ki s PVC izolacijom za napone do 1 kV- mjerni s PE i XLPE izolacijom i PVC pla{tom- kabeli sa svjetlovodnim i Cu vodi~em kategorije 5 za lokalne informati~ke

mre`e (LAN)

- za radne temperature od +70 °C do + 160 °C

- umre`ivi polietilen (XLPE)- bezhalogeni te{kogorivi poliolofini

materijala- vatrootporni, s izolacijom i plaštom bez halogenih materijala

- PVC

- gumene mje{avine

POWER CABLES

THERMOPLASTIC INSULATED WIRINGCABLES

AND WIRES

RUBBER INSULATED WIRINGCABLES AND WIRES

SHIPBOARD CABLES

CABLES AND CONNECTORS FOR AIRPORT INSTALLATIONS

TELECOMMUNICATION CABLES

FIBREOPTIC CABLES

CONTROL, INSTRUMENT AND COMPUTER CABLES

MININGCABLES

WELDINGCABLES

SPECIAL CABLES AND WIRES

ENAMELLED WIRE

ALUMINIUM, AND Al-ALLOY ROPES

OPTICALPOWER GROUND WIRE (OPGW)

STEEL ROPES FOR CRANES, SHIPS AND

OTHER APPLICATIONS

INSULATION MATERIALS

- 1 kV insulated with PVC and XLPE

- 6 kV to 36 kV insulated with XLPE and EPDM

- 1 kV to 36 kV selfsupporting cables with XLPE insulation

- power cables and wires

- automotive wires

- insulated with EPDM and sheathed with CR

- flame retardant halogen free cables

- telephone cables with PE insulation

- telephone cables with PVC insulation

- control cables 1 kV with PVC insulation

- instrument cables insulated with PE and XLPE and PVC sheathing

- fibreoptic and copper LAN cables in cat. 5

- for operating temperature +70 ºC to +160 C

- rubber compounds

- crosslinked polyethylene (XLPE)

- halogenfree flame retardant polyolefine

FLEXIBLE

Al-STEEL

AND SLINGS

- ire-resist

- PVC

f ant halogen free cables

º

Page 38: 11 (Brodski i Offshor Kablovi)

TUGONICA

ZAGREB

ZADAR

VA[

HRVATSKI

PARTNER

YOUR

CROATIAN

PARTNER

Utemeljena 1927. Founded in 1927

KAKO NAS NAÆI?HOW TO FIND US?

CENTAR

[UBI]EVA

BRANIMIROVA ULICA

VUKOVARSKA AVENIJAINDUSTRIJSKAZONA

INDUSTRIJSKAZONA

ZAGREB istok

SLAVONSKI BROD

LJUBLJANA

ZAGREB zapad

River

SAVA

Rijeka SAVA

Rijeka SAVA

Energija - komunikacije / Energy - Communication

Tel.: Fax:http: e-mail:

(++385-1) 24 82 600; (++385-1) 24 04 898//www.elka.hr elka-marketing elka.hr@

Koledov ina 1, P.O.Box 150, HR-10001 ZAGREB, CROATIA~