1081748A04 - Prodigy Automatic System HDLV Pump Panel
Transcript of 1081748A04 - Prodigy Automatic System HDLV Pump Panel
Prodigy� Automatic System HDLV� Pump Panel
Customer Product ManualPart 1081748A04
Issued 01/10
NORDSON CORPORATION • AMHERST, OHIO • USA
For parts and technical support, call the Finishing Customer Support Center at (800) 433-9319.
Check http://emanuals.nordson.com/finishing for the latest version.This document is subject to change without notice.
Part 1081748A04 � 2010 Nordson Corporation
Table of Contents
Safety 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Qualified Personnel 1. . . . . . . . . . . . . . . . . . . . . . . . . Intended Use 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Regulations and Approvals 1. . . . . . . . . . . . . . . . . . Personal Safety 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . Fire Safety 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Grounding 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Action in the Event of a Malfunction 2. . . . . . . . . . . Disposal 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Description 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Panel Components 4. . . . . . . . . . . . . . . . . . . . . . . . . .
External Components 4. . . . . . . . . . . . . . . . . . . . . . . Internal Components 5. . . . . . . . . . . . . . . . . . . . . . .
Pump Panel Configuration and Layout 6. . . . . . . . Network Switch Settings 6. . . . . . . . . . . . . . . . . . . .
SW1 Settings 6. . . . . . . . . . . . . . . . . . . . . . . . . . . SW2 Settings 6. . . . . . . . . . . . . . . . . . . . . . . . . . .
Typical Pump Panel Layout 7. . . . . . . . . . . . . . . . . . Pneumatic Diagrams 8. . . . . . . . . . . . . . . . . . . . . . . . .
Pump Panel to Pump Manifolds 8. . . . . . . . . . . . . . Pump Manifolds to Circuit Board 9. . . . . . . . . . . . .
Wiring Diagrams 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Circuit Board to Pump Manifolds 10. . . . . . . . . . . . . Network and Power Wiring Diagram 11. . . . . . . . . .
Parts 12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Using the Illustrated Parts List 12. . . . . . . . . . . . . . . Internal Pump Panel Replacement Parts 12. . . . . . External Pump Panel Replacement Parts 14. . . . . .
Contact UsNordson Corporation welcomes requests for information, comments, andinquiries about its products. General information about Nordson can befound on the Internet using the following address:http://www.nordson.com.Address all correspondence to:
Nordson CorporationAttn: Customer Service555 Jackson StreetAmherst, OH 44001
NoticeThis is a Nordson Corporation publication which is protected by copyright.Original copyright date 2007. No part of this document may bephotocopied, reproduced, or translated to another language without theprior written consent of Nordson Corporation. The information containedin this publication is subject to change without notice.
Trademarks
HDLV, Nordson ,the Nordson logo, and Prodigy are registered trademarksof Nordson Corporation.
Change Record i
Part 1081748A04� 2010 Nordson Corporation
Change RecordRevision Date Change
A03 12/09 Removed manifold assembly part number and added reference to thepump, manifold, and circuit board manual 1081195.
A04 01/10 Replaced solenoid valve 1027412 with 1099534.
Change Recordii
Part 1081748A04 � 2010 Nordson Corporation
Prodigy� Automatic System HDLV� Pump Panel 1
Part 1081748A04� 2010 Nordson Corporation
Prodigy� Automatic System HDLV� Pump Panel
Safety Read and follow these safety instructions. Task-and equipment-specific warnings, cautions, andinstructions are included in equipmentdocumentation where appropriate.
Make sure all equipment documentation, includingthese instructions, is accessible to all personsoperating or servicing equipment.
Qualified Personnel
Equipment owners are responsible for making surethat Nordson equipment is installed, operated, andserviced by qualified personnel. Qualifiedpersonnel are those employees or contractors whoare trained to safely perform their assigned tasks.They are familiar with all relevant safety rules andregulations and are physically capable ofperforming their assigned tasks.
Intended Use
Use of Nordson equipment in ways other thanthose described in the documentation supplied withthe equipment may result in injury to persons ordamage to property.
Some examples of unintended use of equipmentinclude
� using incompatible materials
� making unauthorized modifications
� removing or bypassing safety guards orinterlocks
� using incompatible or damaged parts
� using unapproved auxiliary equipment
� operating equipment in excess of maximumratings
Regulations and Approvals
Make sure all equipment is rated and approved forthe environment in which it is used. Any approvalsobtained for Nordson equipment will be voided ifinstructions for installation, operation, and serviceare not followed.
All phases of equipment installation must complywith all federal, state, and local codes.
Personal Safety
To prevent injury follow these instructions.
� Do not operate or service equipment unless youare qualified.
� Do not operate equipment unless safetyguards, doors, or covers are intact andautomatic interlocks are operating properly. Donot bypass or disarm any safety devices.
� Keep clear of moving equipment. Beforeadjusting or servicing any moving equipment,shut off the power supply and wait until theequipment comes to a complete stop. Lock outpower and secure the equipment to preventunexpected movement.
� Relieve (bleed off) hydraulic and pneumaticpressure before adjusting or servicingpressurized systems or components.Disconnect, lock out, and tag switches beforeservicing electrical equipment.
Prodigy� Automatic System HDLV� Pump Panel2
Part 1081748A04 � 2010 Nordson Corporation
� Obtain and read Material Safety Data Sheets(MSDS) for all materials used. Follow themanufacturer’s instructions for safe handlingand use of materials, and use recommendedpersonal protection devices.
� To prevent injury, be aware of less-obviousdangers in the workplace that often cannot becompletely eliminated, such as hot surfaces,sharp edges, energized electrical circuits, andmoving parts that cannot be enclosed orotherwise guarded for practical reasons.
Fire Safety
To avoid a fire or explosion, follow theseinstructions.
� Do not smoke, weld, grind, or use open flameswhere flammable materials are being used orstored.
� Provide adequate ventilation to preventdangerous concentrations of volatile materialsor vapors. Refer to local codes or your materialMSDS for guidance.
� Do not disconnect live electrical circuits whileworking with flammable materials. Shut offpower at a disconnect switch first to preventsparking.
� Know where emergency stop buttons, shutoffvalves, and fire extinguishers are located. If afire starts in a spray booth, immediately shut offthe spray system and exhaust fans.
� Clean, maintain, test, and repair equipmentaccording to the instructions in your equipmentdocumentation.
� Use only replacement parts that are designedfor use with original equipment. Contact yourNordson representative for parts informationand advice.
Grounding
WARNING: Operating faultyelectrostatic equipment is hazardous andcan cause electrocution, fire, orexplosion. Make resistance checks partof your periodic maintenance program. Ifyou receive even a slight electrical shockor notice static sparking or arcing, shutdown all electrical or electrostaticequipment immediately. Do not restartthe equipment until the problem hasbeen identified and corrected.
Grounding inside and around the booth openingsmust comply with NFPA requirements for Class 2,Division 1 or 2 Hazardous Locations. Refer toNFPA 33, NFPA 70 (NEC articles 500, 502, and516), and NFPA 77, latest conditions.
� All electrically conductive objects in the sprayareas shall be electrically connected to groundwith a resistance of not more than 1 megohmas measured with an instrument that applies atleast 500 volts to the circuit being evaluated.
� Equipment to be grounded includes, but is notlimited to, the floor of the spray area, operatorplatforms, hoppers, photoeye supports, andblow-off nozzles. Personnel working in thespray area must be grounded.
� There is a possible ignition potential from thecharged human body. Personnel standing on apainted surface, such as an operator platform,or wearing non-conductive shoes, are notgrounded. Personnel must wear shoes withconductive soles or use a ground strap tomaintain a connection to ground when workingwith or around electrostatic equipment.
� Operators must maintain skin-to-handle contactbetween their hand and the gun handle toprevent shocks while operating manualelectrostatic spray guns. If gloves must beworn, cut away the palm or fingers, wearelectrically conductive gloves, or wear agrounding strap connected to the gun handle orother true earth ground.
� Shut off electrostatic power supplies andground gun electrodes before makingadjustments or cleaning powder spray guns.
� Connect all disconnected equipment, groundcables, and wires after servicing equipment.
Action in the Event of a Malfunction
If a system or any equipment in a systemmalfunctions, shut off the system immediately andperform the following steps:
� Disconnect and lock out electrical power. Closepneumatic shutoff valves and relieve pressures.
� Identify the reason for the malfunction andcorrect it before restarting the equipment.
Disposal
Dispose of equipment and materials used inoperation and servicing according to local codes.
Prodigy� Automatic System HDLV� Pump Panel 3
Part 1081748A04� 2010 Nordson Corporation
Description The pump panel is the central electrical andpneumatic enclosure for Prodigy HDLV pumpsused with Prodigy Automatic Spray Guns. Thepanels are installed on the sides of the ProdigyPowder Feed Center. The pump panels areavailable in four, six, and eight pumpconfigurations. Each panel houses the ProdigyHDLV pumps, pump manifolds and pump controlboard, air filter and pneumatic controls, and DCpower supply.
This manual provides panel wiring and pneumaticdiagrams and replacement parts only. Refer to thepowder feed center manual for operationinstructions.
Refer to the following manuals for additional repairand parts information:
1081195 HDLV Pump1062382 HDLV Pump Manifold and Circuit Board
Figure 1 Prodigy Automatic System HDLV PumpPanel (Eight-Pump Panel Shown)
Prodigy� Automatic System HDLV� Pump Panel4
Part 1081748A04 � 2010 Nordson Corporation
Panel Components External Components
7
2
3
4
1
5
6
8
10
9
11
Figure 2 External Pump Panel Components (Eight-Pump Panel Shown)
1. Prodigy HDLV Pumps2. IN Filtered air supply
(pump assist/pattern air flow)3. IN Air supply (pinch and vacuum)
4. Pattern air out5. INPUT power6. NET/PWR to feed center network
junction box7. Vacuum exhaust mufflers
8. Purge pilot−bottom bank ofpumps
9. Purge pilot−top bank ofpumps
10. Accumulator tank11. Purge air tubing/Y-connectors
Prodigy� Automatic System HDLV� Pump Panel 5
Part 1081748A04� 2010 Nordson Corporation
Internal Components
1
2
3
4
5
6 7 98
10
1112
Figure 3 Internal Pump Panel Components (Eight-Pump Panel Shown)
1. Pump control manifolds2. Pump circuit boards3. Power and network terminal strip4. Filter
5. Fuses6. 145 W power supply7. Vacuum air regulator
(50 psi/3.4 bar)8. Pinch high air regulator
(70 psi/4.8 bar)
9. Pinch low air regulator(35 psi/2.4 bar)
10. Pump assist/pattern air flowregulator
11. Pinch select manifold12. Purge pilot manifold
Prodigy� Automatic System HDLV� Pump Panel6
Part 1081748A04 � 2010 Nordson Corporation
Pump Panel Configuration and Layout
The pump panel is available in 4-, 6-, and 8-pump configurations. Up to four pump panels may beconnected to a single powder feed center.
Network Switch Settings Use the following guidelines to set switches SW1and SW2 on each HDLV pump circuit board.
SW1 Settings
SW1 identifies the sequential nodeaddress of the circuit board.
Each circuit board controls two pumps. Refer tothe following chart and Figure 5 for a description ofhow to set SW1.
SwitchPosition
Pumps Controlled
Left Side ofFeed Center
Right Side ofFeed Center
1 1, 2 17, 18
2 3, 4 19, 20
3 5, 6 21, 22
4 7, 8 23 ,24
5 9, 10 25, 26
6 11, 12 27, 28
7 13, 14 29, 30
8 15, 16 31, 32
SW2 Settings
See Figure 4. SW2 identifies the pump paneladdress and the type of gun (manual or automatic)that is controlled by the circuit board.
Switch Position
1Down: Panels 1 and 2 (Guns 1−16)
Up: Panels 3 and 4 (Guns 17−18)
2 Down (not used)
3 Down (not used)
4Down: Automatic Guns
Up: Manual Guns
1 2 3
OPEN
4
Gun Group
= Guns 17−32
= Guns 1−16
1
2
Not Used
3
Gun Type
= Manual
= Automatic
4
Figure 4 SW2 Settings
Prodigy� Automatic System HDLV� Pump Panel 7
Part 1081748A04� 2010 Nordson Corporation
Typical Pump Panel Layout
Figure 5 shows the layout and switch settings of atypical powder feed center. The example shows alayout that controls 28 automatic and four manualpowder spray guns.
Pump panel layout typically follows theseguidelines:
� A powder feed center may have up to fourseparate pump panels.
� Each pump panel may control up to eightpumps.
� One circuit board controls two pumps.
� Manual guns are typically connected to the lastpumps in the feed center.
� The network must be terminated at the lastcircuit board in the feed center.
W1CAN BUS TERM
A8 A7 A6 A5
A4 A3 A2 A1
A16 A15 A14 A13
A12 A11 A10 A9
A24 A23 A22 A21
A20 A19 A18 A17
M4 M3
A28 A27 A26 A25
2
Left Side of Feed Center
A1
1
Pump Manifold(A=Automatic, M=Manual)
SW1
SW2
1 Network Termination:Jumper across pins 1 and 2on last board in feed center
Right Side of Feed Center
1
4 3
2 1
4 3
6 5
7 8
6 5
8 7
Legend
M2 M1
Figure 5 Typical Pump Panel Layout
Prodigy� Automatic System HDLV� Pump Panel8
Part 1081748A04 � 2010 Nordson Corporation
Pneumatic Diagrams Pump Panel to Pump Manifolds
Figure 6 Pump Panel Pneumatic Diagram − Pump Panel to Pump Manifolds (Eight-Pump Panel Shown)
Air Pressure Settings
Function Setting
Vacuum 3.4 bar (50 psi)
Pinch High 4.8 bar (70 psi)
Pinch Low 2.4 bar (35 psi)
Prodigy� Automatic System HDLV� Pump Panel 9
Part 1081748A04� 2010 Nordson Corporation
Pump Manifolds to Circuit Board
8 7 6 5 4 3 2 1
(BOTTOM VIEW)
56
8 7
(BOTTOM VIEW)
3 4
21
PUMP/MANIFOLD
1
PUMP/MANIFOLD
2
8
7 5
6
13
4 2
INSTALL TUBING BEFOREMOUNTING BOARDS
SW1
SW2
Figure 7 Pump Panel Pneumatic Diagram − Pump Manifolds to Circuit Board
Prodigy� Automatic System HDLV� Pump Panel10
Part 1081748A04 � 2010 Nordson Corporation
Wiring Diagrams Circuit Board to Pump Manifolds
SW1
+24VDC
BLACKBLACK
RED
BLU
EB
RN
GR
N/Y
EL
BLU
E
BR
NG
RN
/YE
L
+24VDC
BLACK
BLU
EB
RN
GR
N/Y
EL
RED
1
8
1
4 3 2 1
8
1
J3PATT B
SOL
1
J4PUMP B SOL
1 1
J2PUMP A
SOL
1
J1PATT ASOL
1
P4
J5
P2PUMP
B
P1PUMP
A
P5CANOUT
P6CAN IN
W1CAN BUS
TERM
1 1
P3DC
POWER
GR
N/Y
EL
BR
NB
LUE
+24VDC BLUE
GND GRN/YEL
PATTERN BRN
+24VDC BLUE
GND GRN/YEL
FLOW BRN
SOL.7SOL.1
HDLV PUMP CONTROL MANIFOLD
GND GRN/YELFLOW BRN
+24VDC BLUE
GND GRN/YEL
FLOW BRN
+24VDC BLUE
5
3
7
2
4
6
1
3
5
6
4
1
2
7
SOL.2
SOL.5
SOL.3
SOL.4
SOL.6SOL.7
SOL.2
SOL.5
SOL.4
SOL.1
SOL.3
SOL.6
2 HDLV PUMP CONTROL MANIFOLD1
TO HDLV PUMPCONTROL MANIFOLD 2
SOLENOIDS 1 − 7
TO HDLV PUMPCONTROL MANIFOLD 1
SOLENOIDS 1 − 7
PRODIGY
DUAL PUMP
CONTROLLER
SW2
Figure 8 Circuit Board to Pump Manifolds Wiring Diagram
Prodigy� Automatic System HDLV� Pump Panel 11
Part 1081748A04� 2010 Nordson Corporation
Network and Power Wiring Diagram
BR
OW
N
BLU
E
145W
PO
WE
R S
UP
PLY
BLA
CK
GR
AY
OR
AN
GE
RE
D
SK
2
456 23 1
L1 (
5)S
K1 L2
(3)
BLA
CK
1
81
43
2181
J3
1
J4
11
J2
1
J1
1
P4
J5
P2
P1
P5
P6
W1
11
P3
PINCH 1PINCH 2
PURGE 1PURGE 2
RE
D
REDBLACK
REDBLACK
GRAYBLACK
RED
ORANGE
PIN
CH
SE
LEC
TM
AN
IFO
LD
REDBLACK
REDBLACK
PU
RG
E P
ILO
TM
AN
IFO
LD
TERMINALBLOCK
SW
2
SW
1
P3
11
1
W1
P4
1
8
P6
P5
11
11
41
23
SW
2
SW
1
8
11
J3
W1
1
P4
P6
P5
11
P3
32
14
SW
2
P5
P4
1
P6
1
J2P
2
1
1 8J3
J4
J5
11
1
J1
SW
1
P1
1
81
J4P
2
1J5
811
1
P3
W1
1
14
32S
W2
P1
J1J21
1
81 SW
1
REDBLACK
ORANGEGRAY
GR
AY
GR
AY
BLA
CK
RE
D
OR
AN
GE
BLA
CK
OR
AN
GE
RE
D
REDBLACK
ORANGEGRAY
RED
GRAYORANGE
BLACK
BLA
CK
RE
D
22”
CU
TLE
NG
TH
FU
SE
HO
LDE
RS
106
8938
FU
SE
S 9
3914
4
BROWNBLUE
GRN/YEL
L (L
1 −
HO
T)
N (
L2 −
NE
UT
RA
L)
BR
OW
N
BLU
E
BLUE
BROWN
L1L2
GR
EE
N/Y
EL
FILTER334805
1
4
52
3
BLU
E
BR
OW
N
HA
RN
ES
S,P
UM
PC
ON
TR
OLL
ER
,FIL
TE
R
PO
WE
R S
UP
PLY
EN
D V
IEW
BO
AR
D 2
BO
AR
D 1
BO
AR
D 3
BO
AR
D 4
SE
E S
WIT
CH
DE
TAIL
SC
OR
RE
SP
ON
DS
WIT
HB
OA
RD
NU
MB
ER
AD
JUS
T V
OLT
AG
ET
O 2
4.0V
0.
1V
GR
N/Y
EL
GN
D (
1)
CA
N N
ET
WO
RK
IN
(FR
OM
IC
ON
TR
OL
OR
PR
EV
IOU
S P
UM
P P
AN
EL)
CA
N N
ET
WO
RK
OU
T
(TO
NE
XT
PU
MP
PA
NE
L O
R M
AN
UA
L G
UN
INT
ER
FAC
E)
GRN/YEL
1
1
W1
CA
N B
US
TE
RM
JUM
PE
R P
INS
2 &
3T
YP.
AL
LB
OA
RD
S
Figure 9 Network and Power Wiring Diagram
Prodigy� Automatic System HDLV� Pump Panel12
Part 1081748A04 � 2010 Nordson Corporation
Parts
To order parts, call the Nordson Finishing Customer Support Center at (800) 433-9319 or contact your localNordson representative.
Internal Pump Panel Replacement Parts See Figure 10.
Item Part Description Quantity Note1 - - - - - - MANIFOLD ASSEMBLY, HDLV pump control AR A, C
2 1092274 KIT, PCA replacement, Prodigy pump control AR B
3 334805 FILTER, line, RFI, power, 10 A 1
4 1068938 FUSE BLOCK, pump control 1
5 939144 � FUSE, 4amp, slo blow, fast acting, 250 V 2
6 1069113 POWER SUPPLY, 145 Watt 1
7 1077780 REGULATOR ASSEMBLY, 3, Prodigy 1
8 1064135 � REGULATOR, manifold, modular style 3
9 1065536 � GAUGE, air, 0−100 psi, 0.7 bar, 1/8 in. RPT 3
10 1033878 REGULATOR, rolling diaphragm, 0−120 psi,1/2 in.-NPT
1
11 1099534 VALVE, solenoid, 3 port, 24 V, with adapter 4 D
12 1062364 MANIFOLD, 2 station, 6-mm tube x 1/8-in. RPT 2
NOTE A: When replacing manifold, perform calibration procedure as described in Manual Gun Controller manual.
B: When replacing the circuit board, refer to Pump Panel Configuration and Layout on page 6 for switchsettings. Also perform calibration procedure as described in Manual Gun Controller manual.
C: For manifold assembly part numbers, refer to manual 1081195.
D: If using an old harness with 3 positions, use the supplied adapter. If using a new harness with 2 positions,the supplied adapter can be discarded.
NS: Not Shown
AR: As Required
Prodigy� Automatic System HDLV� Pump Panel 13
Part 1081748A04� 2010 Nordson Corporation
1
2
3
4, 5
6 7
10
12
11
8
9
Figure 10 Internal Pump Panel Replacement Parts (Eight-Pump Panel Shown)
Prodigy� Automatic System HDLV� Pump Panel14
Part 1081748A04 � 2010 Nordson Corporation
External Pump Panel Replacement Parts See Figure 11.
Item Part Description Quantity Note1 1040664 MUFFLER, male, 1/4-in. BPST AR2 1081194 PUMP ASSEMBLY, HDLV AR3 1087160 TANK, accumulator, pump controller 1
AR: As Required
2
1
3
Figure 11 External Pump Panel Replacement Parts (Eight-Pump Panel Shown)
Coating and Finishing Systems GroupNordson CorporationAmherst, Ohio, USA
DECLARATION of CONFORMITY
PRODUCT:
Prodigy HDLV Automatic Pump System, 4-8 ApplicatorsAutomatic Pump System for use with Automatic Applicators and Prodigy iControl
APPLICABLE DIRECTIVES:
98/37/EEC (Machinery)2006/95/EC (Low-V oltage Directive)2004/108/EEC (Elecromagnetic Compatibility Directive)87/404/EEC (Simple Pressure Vessel Directive)
STANDARDS USED TO VERIFY COMPLIANCE:
IEC60417 EN61000-6-2 NFPA79EN12100 EN61000-6-3EN60204 EN55011
PRINCIPLES:
This product has been manufactured according to good engineering practice.The product specified conforms to the directive and standards described above.
Quality Certificate:
DNV ISO9001:2000
Date: 30 April 2008
Joseph SchroederEngineering Manager, Finishing Product Development Group
Nordson Corporation � Westlake, Ohio DOC14020A03