CONUS II The new EN 54-3 compliant signalling device

Transcript of 102562 DET0001-Broschüre-6-Seiter-CONUS-2-06-2018-FINAL … · 2019. 3. 19. · of technical...

  • CONUS IIThe new EN 54-3 compliant signalling device

  • ADDED-VALUE SIREN......is the fi tting term for the new multi-tone CONUS II siren.

    FLEXIBLE... ...for any situation.

    The volume of the 41 signal tones, which can be individually adjusted in four levels, delivers an optimised acoustic alarm, even in situations where it really needs to be truly loud.

    The product range is being expanded once again with the new loop-controlled CONUS II. As a connected loop device, the acoustic signalling device seamlessly joins the CONUS product family.

    Every building’s individual hazards are signifi cantly infl uenced by the building type and how the building is used. Reliable alarm triggering requires optimally coordinated pro-cesses.

    In connection with the DC 3500* fi re control panel, individual signal tones can be used to implement diff erent alarm scenarios, such as fi re alarm, evacuation, panic alarm and other building-specifi c alarms.

    CAMPUSpanic alarm

    INDUSTRYwarning signalHOTEL

    evacuationOFFICEfi re alarm

    *system software V3.4 and higher

  • 1

    2

    3

    FCP

    F30**

    4

    WHEN IT REALLY MATTERS......it’s good to have reserves!

    This additional energy source reduces the neces-sary energy requirement on the loop and allows for 100% uninterrupted alarm triggering in the event of an incident.

    Thanks to the integrated battery, which has an average service life of eight years, the CONUS II can also function as a standalone device.

    Normal operation

    Alarm

    Alarm + fault

    – loop

    – loop

    – loop

    + loop

    + loop

    + loop

    buff ered

    independent

    secure

    If an alarm is triggered, the battery automatically supplies the required power for the acoustic alarm without interruptions.

    A wire breakage or short circuit on the loop, repeat-ed faults as a result of a fi re and even a total failure of the loop will not aff ect the triggered alarm.Due to the decentralised supply of power to the

    signalling device, an F30 fi re protection housing and cabling with functional integrity are not needed for the acoustic alarm trigger1. The material and instal-lation costs are signifi cantly reduced and operation-al security is increased at the same time.

    ** F30 fi re protection housing1 depending on the building and the alarm concept in place

    8 years

  • SPACE FOR TWO......under one ceiling.

    There are no additional costs for installing the fi re detector. If the detector is replaced, only the detector head needs to be handled, rather than the entire unit.

    If the CONUS II is intended for operation without an automatic detector, the detector base is closed with a decorative cap.

    The modular design with a base plate allows for com-plete pre-wiring even while the building is still being constructed.

    The integrated detector base, when installed in the ceiling, can hold one series PL fi re detector.

    » Construction product as per EN 54-3 with synchronised signal output

    » Energy reserves – the integrat-ed long-life battery guarantees an uninterruptible alarm at all times even in the event of a wire breakage or short circuit on the loop, thereby meeting (M)LAR requirements

    » Integration in the Loop 3000 topology and permanent moni-toring as per DIN VDE 0833-2

    » Alarm trigger not aff ected by repeated loop interruption as per DIN VDE 0833-2 or complete failure of the loop

    » Integrated detector base for holding series PL fi re detector

    » No F30 fi re protection hous-ing1 and cabling with functional integrity required thanks to the decentralised supply to the sig-nalling device

    » Four programmable volume levels

    » 41 diff erent signal tones includ-ing DIN ton 33404

    » Four diff erent alarm scenarios

    » Wall and ceiling installation with base plate for pre-wiring during construction phase

    Flexible useCan either be used with an automatic integrable PL fi re detec-tor or with a decorative cap.

    YOUR AD-VANTAG-ES AT A GLANCE

    ***

    1 depending on the building and the alarm concept in place

    factory version*** cap

    accessoryoptional

    fi re detector

  • SIGNAL EFFECT...

    Reliable, coordinated, high-quality products for fi re detection tech-nology. Development, production and sales with the shared synergy of a strong partnership and years of expertise.

    …through market-driven technology and strategy in con-nection with DEFnetwork, a long-standing French com-pany and Europe’s largest independent manufacturer of technical system fi re protection, Detectomat GmbH is paving the way for the future.

    TECHNICAL DATACONUS II

    Specifi cation Multi-tone siren for acoustic alarm triggering as per EN 54-3

    Noise level Max. 98 dB (A) @ 1 m,4-level volume programming via DPT

    Signal tones Individual confi guration via DPT (41 tones, 4 diff erent alarm scenarios, 4 volume levels)

    Voltage supply 15 V to 32 V (abs. max. 34 V) and integrated battery for alarm triggering

    Battery Service life approx. 8 years

    Housing ABS

    Colour White PL 3300w CONUS S (item no. 33670)Red PL 3300r CONUS S (item no. 33671)

    Dimensions (H × D) 76 mm x 145 mm

    Weight Approx. 345 g (including battery)

    Degree of protection IP41

    Detector base Integrated, for holding series PL fi re detector

    VdS approval Pending

    CPD number CNBOP 5291

  • DETECTOMAT SYSTEMS GmbH

    An der Strusbek 3 22926 AhrensburgGermany

    www.detectomat.com

    Subject to technical changes. © 2018 DETECTOMAT GmbH