100 OMEGA AIR: Oil/water separation equipment WOs sERIEs ...
Transcript of 100 OMEGA AIR: Oil/water separation equipment WOs sERIEs ...
100 OMEGA AIR: Oil/water separation equipment
DEPRESSuRIZE CHAMBER WITH AIR FILTER
INLET» condensate (oil, water)» air AIR OuTLET
» condensate (oil, water)
OIL FILTER CARTRIDGE(polypropilene fibres)
ACTIvATED CARBON FILTER CARTRIDGE- final oil elimination
CLEAN WATER OuTLETresidual oil content <10ppm
1st stage chamber
2nd stage chamber
ADvANTAGES
No complex sizing required.
Simple to install.
Works with any type od condensate drain.
Can handle and separate any type of oil.
Oil residue value is less than 10 ppm.
Easy to maintain.
No condensate settling tank is required (therefore there is no bacteria build-up).
Small compact design.
Test valve and test set included for sampling purposes.
WOs sERIEs WATER - OIL sEPARATORs APPLICATIONS• compressed air systems
operating temp. range
inlet connection
DESCRIPTIONWOS water oil separators have been developed to separate lubricant oil from condensate from compressed air systems.
WOS water-oil separator can be used in variety of applications. For applications not listed please contact producer or your local distributor.
1,5 to 45 °C
ø10 mm
DIBt number Z-83.5-31
TECHNICAL DATAOperating temperature 1,5 - 45 °C (max 65 °C)(3); 35 - 113 °F (max. 149 °F)(3)
Operating media Condensate (air, water, oil); Non agresive; Not suitable for emulsion
Residual oil content < 10ppm
Service interval When first of following parametres appears:
- 4000 operating hours of compressor (4)
- 12 months regardless of compressor operating hours
- outlet oil concentration reaches concentration determined with local directives
Technical data Cold climate zone15 °C 60 %RH
Mild climate zone25 °C 60 %RH
Hot climate zone40 °C 100 %RH
Dimensions [mm]A B C
WOS-4Max oil adsorption [kg] 2,89 2,43 1,23
416 243 411Max FAD [Nm3/min]/[scfm] 4,82/170 4,04/142 2,05/72,3
Max condensate flow [l/h] 2,3 3,4 6,3
WOS-8Max oil adsorption [kg] 6,01 5,04 2,55
730 343 680Max FAD [Nm3/min]/[scfm] 10,0/353 8,4/296 4,25/150
Max condensate flow [l/h] 4,7 7,1 13,1
WOS-20Max oil adsorption [kg] 14,64 12,28 6,22
820 366 940Max FAD [Nm3/min]/[scfm] 24,4/861 20,5/723 10,37/366
Max condensate flow [l/h] 11,4 17,2 32,0
WOS-35Max oil adsorption [kg] 25,4 21,31 10,79
960 386 1137Max FAD [Nm3/min]/[scfm] 42,3/1495 35,5/1254 17,99/635
Max condensate flow [l/h] 19,8 29,8 55,6
C
A B
101OMEGA AIR: Oil/water separation equipment
Water quality test
Water quality test should be performed at least once per month, to control the contamination level of disposed condensate.
If oil concentration is reached, oil filter cartridges must be changed.
(3) Max. operating temperature is 65 °C, but when temperature is over 45 °C, performance may decrease.(4) At compressor oil carryover 2,5 mg/m3. Lower/higher oil carry over means proportionally longer/shorter lifetime (e.g. if oil carryover is 5mg/m3 lifetime
reduces to 2000 operating hours).