1 LIGO-G1001031-V5 LLO CDS Components Front End Computer Timing Master 18VDC18VDC I/O Extension...

6
1 LIGO-G1001031-V5 LLO CDS Components Front End Computer Front End Computer Timing Master 1 8 V D C I/O Extensio n Timing Fanout 2 4 V D C Chassis Chassis Chassis Chassis Chassis Chassis DC Power DC Power DC Power DC Power DC Power DC Power A C V o l t a g e Chassis Chassis Chassis Chassis Chassis Chassis Mass Storage Room (MSR) Operator Control Room (OCR) CDS Electronic s Room (CER ) Laser Diode Room (LDR ) CDS Power Room (CPR ) Field I/O Cables Timing Distribution Cables DC Power Racks Field Satellite Racks Subsystem Electroni cs Racks Front End Racks Fiber Optic Cables DC Extension Cables Fiel d DC Extension Cords Computer Users Room (CUR) Racks and Rooms (RAR) LVEA Racks (LVEA) X-End Racks (X-End ) Y-End Racks ( Y-End ) Electronic s Test Racks (ETR)

Transcript of 1 LIGO-G1001031-V5 LLO CDS Components Front End Computer Timing Master 18VDC18VDC I/O Extension...

Page 1: 1 LIGO-G1001031-V5 LLO CDS Components Front End Computer Timing Master 18VDC18VDC I/O Extension Timing Fanout 24VDC24VDC Chassis DC Power AC VoltageAC.

1LIGO-G1001031-V5

LLO CDS Components

Front End Computer

Front End Computer

Timing Master

18VDC

I/O Extension

Timing Fanout

24VDC

Chassis

Chassis

Chassis

Chassis

Chassis

Chassis

DC Power

DC Power

DC Power

DC Power

DC Power

DC Power

AC Voltage

Chassis

Chassis

Chassis

Chassis

Chassis

Chassis

MassStorageRoom (MSR)

OperatorControlRoom (OCR)

CDS ElectronicsRoom (CER)

LaserDiode

Room (LDR)

CDS Power

Room (CPR)

Field I/O

Cables

TimingDistribution

Cables

DCPowerRacks

Field Satellite

Racks

Subsystem

Electronics

Racks

FrontEnd

Racks

FiberOptic

Cables

DC Extension

Cables

FieldDC

ExtensionCords

Computer Users Room (CUR)

Racks and Rooms (RAR)

LVEA Racks (LVEA)

X-End Racks (X-End)

Y-End Racks (Y-End)

Electronics Test Racks

(ETR)

Page 2: 1 LIGO-G1001031-V5 LLO CDS Components Front End Computer Timing Master 18VDC18VDC I/O Extension Timing Fanout 24VDC24VDC Chassis DC Power AC VoltageAC.

CDS Electronics Room (CER) Rack Layout

2LIGO-G1001031-V5

2feet

Each Rack is 39” Deep and 24”

Wide

2 feet

L1

-OA

F-C

1

L1-SUS-C1

L1-SUS-C2

L1-SUS-C3

L1-SUS-C4

L1-SUS-C5

L1-SUS-C6

L1-SUS-C7

L1-SUS-C8

L1

-SEI-

C1

Fro

nt F

ron

t

Front Front

Fro

nt

Fro

nt

L1

-SEI-

C2

L1

-TC

S-C

1

L1

-SEI-

C3

L1

-SEI-

C4

L1

-SEI-

C5

L1

-SEI-

C6

L1-UNK-C3

L1-UNK-C2

L1-UNK-C1

L1-ISC-C1

L1-ISC-C2

L1-ISC-C3

L1

-PS

L-C

1

CDS Electronics Room (CER)

L1-ISC-C4

L1

-UN

K-C

5

SUS ITMX, ITMY, FMX,

FMY, and BS Rack 1

SUS HAM3 and HAM4

Rack 2

SUS HAM3 and HAM4

Rack 1

SUS HAM2 Rack 1

SUS HAM2 Rack 2

SUS ITMX, ITMY, FMX,

FMY, and BS Rack 2

SUS HAM5 and HAM6

Rack 1

SUS HAM5 and HAM6

Rack 2

ISC LVEA Rack 1

ISC LVEA Rack 2

ISC LVEA Rack 3

PS

L R

ack 1

DA

Q R

ack

1

TC

S R

ack 1

Front

SEI

HA

M1

an

d H

AM

6

SEI

HA

M2

an

d H

AM

3

SEI

HA

M4

an

d H

AM

5

SEI

BS

C1

SEI

BS

C2

SEI

BS

C3

ISC LVEA Rack 4

Page 3: 1 LIGO-G1001031-V5 LLO CDS Components Front End Computer Timing Master 18VDC18VDC I/O Extension Timing Fanout 24VDC24VDC Chassis DC Power AC VoltageAC.

3

Laser Diode Room (LDR) Rack Layout

LIGO-G1001031-V5

CDS Power Room (CPR)

Fro

nt

Front

L1

-VD

C-C

5

L1-VDC-C7

L1

-VD

C-C

1

L1

-VD

C-C

2

L1

-VD

C-C

3

L1

-VD

C-C

4

L1-VDC-C6

2feet

Each Rack is 39” Deep and 24” Wide

Laser Diode Room (LDR)

Changing Room

480V DistributionPanel

208V DistributionPanel

DC Supplies

2feet

20

8V

Dis

trib

uti

on

Pan

el –

CD

S1

20

8V

Dis

trib

uti

on

Pan

el –

CD

S2

LDR Chiller

L1-LDR-C2

L1-LDR-C1

2 feet

Transformer

Page 4: 1 LIGO-G1001031-V5 LLO CDS Components Front End Computer Timing Master 18VDC18VDC I/O Extension Timing Fanout 24VDC24VDC Chassis DC Power AC VoltageAC.

4

CDS Power Room (CPR) Rack Layout

LIGO-G1001031-V5

Transformer

2feet

Each Rack is 39” Deep and 24” Wide

2 feet

Laser Diode Room (LDR)

Changing Room

480V DistributionPanel

208V DistributionPanel

DC Supplies

2feet

20

8V

Dis

trib

uti

on

Pan

el –

CD

S1

20

8V

Dis

trib

uti

on

Pan

el –

CD

S2

LDR Chiller

L1-LDR-C2

L1-LDR-C1

CDS Power Room (CPR)

Fro

nt

Front

L1

-VD

C-C

5

L1-VDC-C7

L1

-VD

C-C

1

L1

-VD

C-C

2

L1

-VD

C-C

3

L1

-VD

C-C

4

L1-VDC-C6

Page 5: 1 LIGO-G1001031-V5 LLO CDS Components Front End Computer Timing Master 18VDC18VDC I/O Extension Timing Fanout 24VDC24VDC Chassis DC Power AC VoltageAC.

5

CDS Electronics Room X-End (CERX) Rack Layout

LIGO-G1001031-V5

(L1-FAC-XC1)

CER

X

(L1-V

DC

-XC

1)

(L1-V

DC

-XC

2) (L1-DAQ-XC1)

(L1-SEI-XC1)

(L1-SUS-XC1)

(L1-SUS-XC2)

(L1-TCS-XC1)

Page 6: 1 LIGO-G1001031-V5 LLO CDS Components Front End Computer Timing Master 18VDC18VDC I/O Extension Timing Fanout 24VDC24VDC Chassis DC Power AC VoltageAC.

6

CDS Electronics Room Y-End (CERY) Rack Layout

LIGO-G1001031-V5

CERY

(L1-VDC-YC1)(L1-VDC-YC2)

(L1

-DA

Q-Y

C1

)

(L1

-SEI-Y

C1

)

(L1

-SU

S-Y

C1

)

(L1

-SU

S-Y

C2

)

(L1

-TC

S-Y

C1

)

(L1

-FA

C-Y

C1

)