1 IDT March Cover - Ipp Pharma · implant_dentistry_132x186_MAR.pdf 09/02/2017 14:17 Page 1 Dr...

5
IMPLANT DENTISTRY TODAY March 2017 Vol 11 Issue 2 PROMOTING THE DEVELOPMENT OF IMPLANTS IN GENERAL PRACTICE Guided by the light David Burgess embraces the potential of new technology to perform an internal sinus lift using smart navigation Unsung heroes Is your technician deserving of a Laboratory Award? International leadership Michael Norton: the Association of Osseointegration’s new president Earn three hours of verifiable CPD with this issue Multidisciplinary reconstruction By Chris Wood and Cemal Ucer Immediate full arch treatment By Robert Hayes

Transcript of 1 IDT March Cover - Ipp Pharma · implant_dentistry_132x186_MAR.pdf 09/02/2017 14:17 Page 1 Dr...

Page 1: 1 IDT March Cover - Ipp Pharma · implant_dentistry_132x186_MAR.pdf 09/02/2017 14:17 Page 1 Dr David Burgess BDS DPDS MScConSed has been principal of Carbis Bay Dental Care in Cornwall

IMPLANT DENTISTRYTO

DAY

March 2017Vol 11 Issue 2

PROMOTING THE DEVELOPMENT OF IMPLANTS IN GENERAL PRACTICE

Guided by the light David Burgess embraces the potential of new technology to perform an internal sinus lift using smart navigation

Unsung heroesIs your technician deserving of a Laboratory Award?

International leadershipMichael Norton: the Association of Osseointegration’s new president

Earn three hours of verifiable

CPD with this issue

Multidisciplinary reconstruction By Chris Wood and Cemal Ucer

Immediate full arch treatmentBy Robert Hayes

Page 2: 1 IDT March Cover - Ipp Pharma · implant_dentistry_132x186_MAR.pdf 09/02/2017 14:17 Page 1 Dr David Burgess BDS DPDS MScConSed has been principal of Carbis Bay Dental Care in Cornwall

26 March 2017 IDT

IMPLANT ESSENTIALS

was wide enough to consider flapless surgery. This had added appeal, as the patient was travelling a great distance for the treatment, so wished to minimise the number of appointments and the potential for postoperative complications.

Computer-guided dynamic navigation with Navident by Claronav was used in the preparation of this case.

Scanning and planning took place during the assessment visit, 48 hours before implant surgery.

A Navistent was fabricated and a fiducial marker attached, prior to the CBCT scan.

The patient was unwilling to consider a denture and was not keen for the symptomless adjacent teeth to be prepared for bridgework, particularly the upper right first premolar, which was unfilled.

She did not wish to have any form of removable prosthesis. She chose to have implant-supported crowns, as she wanted the final restoration to be as close as possible to having natural teeth.

Clinical examination and planningClinical examination suggested that the buccopalatal width of the maxillary ridge

A 52-year-old female patient was concerned about the appearance of her smile. Her upper right first molar and second premolar had been missing for several years (Figures 1 and 2). She was otherwise a fit and healthy non-smoker.

Reliable and predictable flapless implant placement David Burgess describes how using computer-guided dynamic navigation enabled him to accurately place implants within optimum bone, without the need to reflect a flap

With Dental and Facial aesthetics in mind,Swann-Morton have produced a versatile rangeof handles and blades.

The cutting edge expertise embodied within theSwann-Morton Range meet the most demandingand complex requirements presented by modernday Periodontal, Cosmetic, Oral Implantology,and Maxillofacial procedures.

Whether it’s a 15c or 12d scalpel blade beingused for Periodontal surgery, an SM69 Fine bladefor Implants or one of our Safety Scalpels toassist in the implementation of cross infectioncontrols within the Practice, the choice is yours.

Where only Swann-Morton will do.

www.swann-morton.com

Owlerton Green, Sheffield S6 2BJTelephone: 0114 2344231, Sales: 0114 2344223,Fax: 0114 2314966

[email protected]@swann-morton.com

For more information on the Swann-Morton range ofproducts designed for Dentistry, including the lightweightFine Range, please go to our website

the boundaries inDentistryredefining

‘Swann-Morton’ and the ‘RingPattern Logo’ are the registered

trade marks of Swann-MortonLimited and related companies.

‘Swann-Morton’ and the ‘RingPattern Logo’ are the registered

trade marks of Swann-MortonLimited and related companies.

All medical devices are CEmarked in accordance with the

Medical Device Directive(93/42/EEC)

FM 73368EMS 633531

implant_dentistry_132x186_MAR.pdf 09/02/2017 14:17 Page 1

Dr David Burgess BDS DPDS MScConSed has been principal of Carbis Bay Dental Care in Cornwall since 1988. He has placed more than 2,000 implants, and is a willing pioneer of new technology, particularly in the field of digital dentistry. David was the first UK clinician to introduce the Navident dynamic navigation system into his implant treatment workflow.

Page 3: 1 IDT March Cover - Ipp Pharma · implant_dentistry_132x186_MAR.pdf 09/02/2017 14:17 Page 1 Dr David Burgess BDS DPDS MScConSed has been principal of Carbis Bay Dental Care in Cornwall

IDT March 2017 27

Radiographic and CBCT examination revealed approximately 9mm of bone depth, from crest of ridge to floor of maxillary antrum, in the upper right second premolar site, and no more than 5mm bone depth in the first molar site.

Planning took place immediately after the scan, with the patient present so she could see the proposed treatment on the Navident software.

She felt reassured by the care being taken to achieve optimum implant positioning, with minimal risk of potential complications, and was extremely impressed with the technology.

The Navident planning software allowed the placement of the implants to be restoratively driven.

The size, shape and position of the intended crowns was planned prior to treatment and the consequent position of the implants determined, so that the optimum restoration could be achieved.

Due to the limited bone depth in the first molar site, augmentation of the ridge was planned by utilising the internal sinus lift (or Summer’s) technique.

The minimally invasive procedure allowed placement of dental implants in a site with reduced bone depth, without causing iatrogenic sequelae through damaging an intact Schneiderian membrane.

Flapless procedureTreatment was carried out under local anaesthesia. The flapless procedure resulted in minimal trauma to the gingival tissue overlying the ridge.

The previously constructed Navistent, and the drill tag and jaw tag supplied by Claronav, were prepared immediately prior to surgery (Figure 3).

In accordance with the Navident protocol, the axis of the drill and tip of the pilot drill were calibrated (Figures 4 and 5) and verified before site preparation commenced (Figure 6).

Using computer-guided surgery, the pathway of the drill could be followed clearly on the computer screen positioned in front of the patient (Figure 7).

Approximately 1mm of bone was left intact in the upper right first molar site ready for the sinus lift.

Navident provided visual confirmation of the position of the drill tip to accurately gauge the correct depth (Figure 8).

Preparation continued using a 3.5mm drill bit, which, again, was calibrated and verified before use (Figures 9 and 10).

A 3.5mm diameter and 8mm length Dentsply Ankylos C/X implant was placed 1mm subcrestally in the upper right second premolar site.

A guide pin was placed in the upper right first molar site to check the depth and alignment (Figure 11).

The Navistent was removed and the site was prepared for the sinus lift osteotome (Figures 12 and 13). The osteotome was

Figures 1 and 2: The patient’s upper right first molar and second premolar had been missing for several years Figure 3: Preparation of Navistent, and drill and jaw tags immediately prior to surgery

Figure 4: Calibration of drill axis

Figure 7: The pathway of the drill could be followed clearly on the Navident computer screen

Figure 5: Calibration of pilot drill tip

Figure 8: Navident provided visual confirmation of the drill tip’s position to accurately gauge the correct depth

Figure 6: Preparation of upper right second premolar implant site

Figure 9: Calibration of 3.5mm drill tip

Figure 1 Figure 2

Page 4: 1 IDT March Cover - Ipp Pharma · implant_dentistry_132x186_MAR.pdf 09/02/2017 14:17 Page 1 Dr David Burgess BDS DPDS MScConSed has been principal of Carbis Bay Dental Care in Cornwall

IDT March 2017 29

IMPLANT ESSENTIALS

Figure 13: Sinus lift osteotome in place

Figure 16: Placement of 4.5mm diameter and 6.6mm length Ankylos C/X implant

Figure 14: The osteotome was tapped gently with a surgical mallet until the remaining thin layer of bone was infractured

Figure 17: Subcrestal implant placement

Figure 19: Computer-guided navigation enabled the implants to be placed reliably and predictably within optimum bone, without the need to reflect a flap

Figure 15: A heterogeneous bovine bone graft material (Bio-Oss) was introduced into the implant site

Figure 18: Ankylos Balance posterior sulcus formers were fitted, without the need for additional closure with sutures

tapped gently with a surgical mallet until the remaining thin layer of bone infractured and was elevated (Figure 14).

The Schneiderian membrane was carefully raised through manipulation with the osteotome and a heterogeneous bovine bone graft material (Bio-Oss) was introduced into the implant site (Figure 15). A 4.5mm diameter and 6.6mm length Ankylos C/X implant was then placed 1mm subcrestally (Figures 16 and 17).

Both implants had good primary stability on placement. Ankylos Balance posterior sulcus formers were fitted, without the need for additional closure with sutures (Figure 18).

Implant placement in optimum boneNavident was used to guide the implant site preparation dynamically, to ensure implants were placed in the pre-determined position without the need for a static drilling guide.

This facilitated placement of the implants in the optimum amount of bone without inadvertent damage to the maxillary sinus membrane. It also ensured that their alignment made future impression taking and restoration straightforward.

The ability to watch the drill virtually on the CBCT scan, as the implant sites were prepared, allowed the exact point at which to cease vertical drilling to be judged visually.

Assessment, planning and placement were carried out within 48 hours, due to the patient’s limited ability to attend for appointments. Using Navident, there is no reason why this could not be achieved in one visit. The implants will be restored two to three months after placement, with custom-made titanium abutments and zirconia crowns.

Computer-guided navigation enabled the implants to be placed reliably and predictably within optimum bone, without the need to reflect a flap (Figure 19). Consequently, the

patient experienced no postoperative swelling or bruising and she reported very little discomfort after treatment.

This outcome satisfied the primary objective of aiming for clinical perfection, while ensuring the patient experienced the least trauma possible.

Figure 10: Preparation of premolar site with 3.5mm drill

Figure 11: A guide pin was placed in the upper right first molar site to check the depth and alignment

Figure 12: The Navistent was removed and the site was prepared for the internal sinus lift

Page 5: 1 IDT March Cover - Ipp Pharma · implant_dentistry_132x186_MAR.pdf 09/02/2017 14:17 Page 1 Dr David Burgess BDS DPDS MScConSed has been principal of Carbis Bay Dental Care in Cornwall

Precision guidance for increased accuracy within 0.5mm of treatment plan*

Easy to use, reducing time and expense with a simplifi ed digital workfl ow

Plans can be modifi ed at any time, even during treatment

Enables minimally invasive fl apless drilling without a physical guide

Provides even greater value from your CBCT data

Precision guidance for increased accuracy within 0.5mm of treatment plan*

Easy to use, reducing time and expense with a simplifi ed digital workfl ow

Plans can be modifi ed at any time, even during treatment

Enables minimally invasive fl apless

Provides even greater value from your CBCT data

See where the tip of the drill actually is, not where you think it is. Navident allows you to prepare the implant site completely freehand and with greater precision and confi dence, using your CBCT data in real time as your virtual guide.

Try Navident’s precision guidance for yourself

“What makes Navident stand out is it precisely guides the surgeon to

prepare and place the implant. The software shows the drill position on the scan in real time, as it enters the jaw.”

David Burgess BDS DPDS MScConSed Carbis Bay Dental Care, St Ives, Cornwall

*Ave

rag

e er

ror

of

0.4m

m in

inte

rnal

ben

ch t

ests

wit

h a

ran

ge

of

op

erat

ing

co

nd

itio

ns.

Dynamic navigation for freehand dental implant placement

Compatible with any implant type, drill system

and all knownCBCT devices

Precision guidance for increased accuracy

Easy to use, reducing time and expense

Plans can be modifi ed at any time, even

Enables minimally invasive fl apless

Provides even greater value from your

Call 0845 602 4944 or email [email protected] NavidentUK

Hands-on dynamic navigation courses now available

Distributed in the UK and Ireland by The Dental Imaging Company Ltd tel: 0845 602 4944

email: [email protected]: www.thedentalimagingcompany.co.uk

Targeting Perfection