Agilent Confidential1
GC-MSDIntroducing the new 7890B/5977A
January 8, 2013
Badr AstiphanGCMS Product Sales Specialist1-866-524-7936302-290-5631 [email protected]

Agilent Confidential2 January 8, 2013
We are First in GCContinuously innovating
5970 MSDFused SilicaCapillary Column
Microprocessor Control
5840 GC
5880 GC
5890 GC
HyperbolicGold Quad
Inert MS Ion Source
6890 GC
7200 GC QTOF7000 GC
Triple Quad
Capillary FlowTechnology
AutoInjection
Electronic PneumaticControl
Retention TimeLocking
2nd Gen LinearElectron Capture
Detector
Low Thermal MassTechnology
Units Installed>250,000 GC>60,000 MS
Multi-ModeInlet
1970’s1980’s
1990’s
2000’s
2010’s

Agilent Confidential3 January 8, 2013
7890A/5975C GC/MSD:The Most Popular GC/MS in the World
Over 20,000 5975 systems since 2005
The industry standard GCMS

Agilent 5977 MSD
January 8, 2013Agilent Confidential
4

Agilent Confidential5
Proven TechnologiesImproving the Industry Standards for GC/SQ
Gold Quartz Quad Triple Axis Detector
High Temperature Inert Source
Unique Entrance Lens Design
All of 5975’s features also built in 5977, such as “Gold Quad”, SIM/Scan, Gain tuning, Triple-Axis Detector, Trace Ion Detection, Auto CI, etc..
January 8, 2013

Agilent Confidential6
230°C
275°C
300°C
325°C
350°C
January 8, 2013
High Temperature Ion Source
Solid inert material – not a coating– Not damaged by multiple cleanings
Programmable to 350ºC Improved response for many compounds
– More robust operation for “dirty” samples – Better response for “sticky” compounds– Sharper peaks for high boilers (late eluters)
… more performance for a wide range of
applications
Polyaromatic Hydrocarbon (PAH)

Agilent Confidential7 January 8, 2013
Unique Entrance Lens Eliminates Pre-filter
New, improved lens

Agilent Confidential8 January 8, 2013
Fringe fields
Unique Entrance Lens Eliminates Pre-filter

Agilent Confidential9 January 8, 2013
Quartz – Gold – Hyperbolic and Beautiful!
Why quartz?
– Low coefficient of linear expansion
(expansivity; α)
• dL = α L0 dt [t = ºC; dL = change in length
(m); L0 = length at 0 ºC]
Why gold?
– Inert material with excellent electrical
properties for high voltage
Why hyperbolic?
– Ideal electrical field is generated by
hyperbolic surfaces (NOT ROUND)
Much more than just a beautiful piece of glass
Round Quad

Agilent Confidential10 January 8, 2013
Triple-Axis Detector
ion beam
X
Y
OffsetZ
With a combination of three axes and appropriate shielding, noise from secondary particles can be reduced to a minimum

Agilent Confidential11 January 8, 2013
Triple Channel EM
Triple channels improve signal amplification
– Lower initial EM voltage required
Triple channels increase life– Lower cost of operation
Exit of the triple channels
Collector removed to show exit passages
Collector

Agilent Confidential12
Expanded Capabilities: 7890B/5977AImproving the Industry Standards for GC/SQ
Higher Ion Count• Extractor EI source• Increased ion count• S/N > 1500:1• IDL < 10 fg (industry first)• Improved thermal profile
Save Time & Energy •Sequence Scheduler• “Standby” post run• “Ready to run” from standby• “Bake Mode” as needed• Factory backflush option• Fast Vent capability• DS42i rough pump“standby” power reduction
Safety/Protection• Vacuum failure Shut off gas (He or H2)
Better Vacuum by Agilent Pump• New Agilent V304 Turbo
• TwisTorr• Molecular Drag technology
• Improved pumping light gases• H2 (220 L/s); He (255 L/s)
• Agilent Floating Suspension• Longer life• Quiet operation
Faster Scanning• 20,000 u/s• But never equal to the 7200 Q-
TOF speed or ‘scan’ sensitivity
7890B GC “Direct Communications Features• EMF, calculator, etc.
January 8, 2013

New Extractor Ion Source for 5977
Agilent ConfidentialPage 13
Why the Extractor EI Source?
Increase in ion count True increase in sensitivity
Better trace level precision Lower IDL and MDL
Proven sensitivity increase demonstrated with over 1500 7000 Series GC/TQ!
January 8, 2013

Comparison of Inert and Extractor Ion Source
Agilent Confidential
Page 14
Repeller(Push)
Drawout Plate
Ion Focus Lens
Entrance Lens
Ionization area
Ions
Inert Ion Source
Extractor Lens(Pull)
Extractor Source
More ions to Mass Filter
Mass Filter
January 8, 2013

Agilent Confidential15
Extractor Source “Etune” Sensitivity Increase
January 6, 2013
Blue – Extractor 40ppb solution (SVOC)Red – Standard 40ppb solution (SVOC)

More improvements on 5977’s Extractor Ion Source: Improved Thermal Profile
Page 16
Why is this important?Better performance of high boilers i.e. PAH even at lower concentration!
+ TIC SIM pah_etune_300_long_R9.D Smooth
Counts (%) vs. Acquisition Time (min)
10 Injections80 min analysis
Good repeatability of PAH even at the trace level (5ppb)!!
Improvement for better Mass Spectrometer of Gas Chromatograph
January 15, 2013

Comparing repeatability of 80min Method
Phthalates analysis with 5977 GC/MSD
Oct 2012Page 17
1x10
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
5
5.5
6
6.5
7
7.5
8
8.5
9
+ TIC SIM PAHs-12.D
Counts (%) vs. Acquisition Time (min)37 37.1 37.2 37.3 37.4 37.5 37.6 37.7 37.8 37.9 38 38.1 38.2 38.3 38.4 38.5 38.6 38.7 38.8 38.9
5977 result
5975 resultTwo years ago
1x10
-0.1
-0.05
0
0.05
0.1
0.15
0.2
0.25
0.3
0.35
0.4
0.45
0.5
0.55
0.6
0.65
0.7
0.75
0.8
0.85
0.9
0.95
1
1.05
1.1
1.15
1.2
+ TIC SIM pah_etune_300_long_R9.D Smooth
Counts (%) vs. Acquisition Time (min)35.2 35.4 35.6 35.8 36 36.2 36.4 36.6 36.8 37 37.2 37.4 37.6 37.8 38 38.2 38.4 38.6 38.8 39 39.2 39.4 39.6 39.8 40
+ TIC SIM pah_etune_300_long_R9.D Smooth
Counts (%) vs. Acquisition Time (min)
+ TIC SIM PAHs-12.D
Counts vs. Acquisition Time (min)
5977 result
200ppb PAH 5ppb PAH

Key features of “Direct Communication” between 7890B and 5977A
Agilent ConfidentialPage 18
Sleep/Wake mode• Sleep mode saves power (320W 190W) Lower lab operating cost
Safety Control• If 5977A MSD pump fail, 7890B will shut off the gas supply
Cool Down MSD Faster (FastVent)• When MSD Vent Cycle started, GC will cool down MSD analyzer at the
optimum gas flow to MSD.
Helium carrier gas : gas waste is eliminated Hydrogen carrier gas: risk of explosion is reduced
40% faster when cooling down from 280C to 100C (< 25 min)
January 8, 2013

Saving Energy and Time
19
Normal Op Standby0
50
100
150
200
250
300
350
400
Power Consumption - 5977
0 4 6 7 15 20 23 30 35 400
50
100
150
200
250
VentFastVent
Power saved
Time saved
Pow
er(
VA
)
So
urc
e T
em
p
Time(min)
Time saved using Fast Vent

Better HW Features: Agilent Turbo Pump (V304)
Agilent ConfidentialPage 20
Agilent Quality Standard
TwisTorr 304 FS
Innovation for: •Higher pumping performance
• especially for He and H2
•High reliability• lower cost of operation
January 8, 2013
Press release : http://www.agilent.com/about/newsroom/presrel/2012/19dec-ca12077.html

21
TwisTorr 304 FS: Vacuum Design
8 EDM turbo stages (rotor) designed to optimize pumping speed for light gases
8 Turbo stators made by pressed SST sheet technology
3 TwisTorr drag stages (spiral channels) designed for high compression ratio performances
Agilent’s new patent-pending Floating Suspension for robust, low noise operation

Better HW Features: Agilent Rough Pumps
Agilent ConfidentialPage 22
New DS42i New IDP-3c
High performanceEnergy saving design“Inverter” not compatible with diff pump
High performanceOil-free scroll pumpNH3 CI compatible
with Agilent Quality Standards
January 8, 2013

Agilent Confidential23 January 8, 2013
Agilent Inert Flow Path … From Injection to Detection
Ultimetal – TCD, FPD, NPD/FID Jets
Ultimetal Capillary Flow TechnologyDevices, Ultimate Union
Ultimetal Inlet Weldment, Shell and Transfer Lines
Ultra Inert GC Column
Ultra Inert Gold Seal
Ultra Inert Inlet Liner
New
…now from a single supplier

Programmable Helium Conservation Module
Works with Gas Saver function of 7890 based GC
Standby Method can be programmed after the sequence ends
Analytical methods are unchanged since Helium is still the carrier during the run

25
5977A GC/MSD IDL Specification
IDL is a statistically derived value from the precision (%RSD) of 8 consecutive, splitless injections of 100fg OFN at 99 % confidence level. The more precise instruments (lower %RSD) will generate lower IDLs.
The Agilent 7890B/5977A with an ALS or CTC autosampler has the following specifications:
January 15, 2013
Ion Source type High Vacuum pump type
IDL of OFN by 8 replicates of ALS*
Extractor Source Turbo Pump 10fg
Inert SourceTurbo Pump 24fg
Diffusion Pump 30fg
*Systems without an Autosampler will have only S/N specification.
These are installation specification, performed on customer site, immediately after installation and carry a lot more value than a reference specs.

26
Why IDL specification is useful for the 5977 in SIM?
Influence of Noise in S/N specs
• In SIM (or MS/MS) when the Noise is too low, such as during acquisition of an OFN standard, S/N results may not give the best characterization
• If the noise level is insignificant - varies a lot and too low- the derived value from it (S/N) also becomes insignificant
Value of IDL
• IDL is derived from reproducibility/precision results, the same metrics most users utilize every day in their work. The IDL statistical process is the same used for Method Detection Limit calculations, and the %RSD values are tools to monitor analytical performance
• IDL characterizes the whole system – AS, GC, MS- giving confidence in overall reliability. It is the results of 8 consecutive injections, unlike S/N in a single shut, which can be influenced by many parameters/conditions
January 15, 2013

27
The Influence of the low Noise on S/N valuesSame Data File, RMS, 5 Second Noise Region
Noise region: 5.66min - 5.74 minS/N: 3335
Noise region: 5.65min - 5.73 min S/N: 10785
A 0.01 min. shift in the noise region resulted a 6000 higher S/N value. When the noise is insignificant (low), the derived S/N value is also insignificant!
Noise region: 5.65min-5.73 min
Noise region:5.66min-5.74 min
S/N S/N
January 15, 2013

Agilent Confidential28 January 8, 2013
Market Leading PerformancePremium Value: The Best Just Got Better
Detector Performance
MSD Scan 1500:1 S/N; SIM 10 fg IDL – Best in Class with IDL tested at installation when ALS or Combi available (with Extractor Source)
FID <1.4 pg C/sec
ECD <4.4 fg/sec
FPD <2.5 pg S/sec; <45 fg P/sec
SCD <0.5 pg S/sec
NPD Best for P, 0.08 pg/sec N beat only by Thermo 0.05 pg/sec– but only using OUR Blos bead!
TCD 400 pg/mL
No one can now offer a better specification package than Agilent

Agilent ConfidentialPage 29
Market’s Best S/N (SNR) > 1500:1
Market’s Best Scan Rate = 20,000 u/s
Market’s ONLY IDL < 10 fg
Better science from AgilentStatistical confirmation of entire system’s performance
January 8, 2013

Agilent Confidential30 January 8, 2013
Mass Hunter GC/MSD Software MassHunter Qual
MassHunter QuantMH
CS
MassHunter GC/MS Acquisition
And Use EitherMassHunter Data Analysis
ORMSD ChemStation Data AnalysisMSD ChemStation DA
G1701FA

Agilent Confidential31 January 8, 2013
MSD ChemStation DA
QEdit
Reports
MSD ChemStationStandard interface
Quantitation
Macros
Library Searching

Agilent Confidential32 January 8, 2013
MassHunter WorkStation Qualitative AnalysisData Navigator
Method Explorer
Chromatogram Results
Method Editor
Spectrum Results

Agilent Confidential33 January 8, 2013
Mass Hunter Quantitative Analysis
Compound Information
Results Information
Batch Information(i.e., Calibration Curve)
Results Informationfor the batch can be displayed. Visual guides highlight specific data that fall outside specific, predefined conditions.
Batch Information provides easy visualization and customization of relevant desired data.
The Quant Batch screen looks like this.
Compound Information displays graphical representation of the peak, qualifier information, spectral information, and the ISTD. Visual guides help identify associated data problems.

Agilent Confidential34 January 8, 2013
Unknowns Analysis

Agilent Confidential35 January 8, 2013
MassHunter Excel Reporting
•Excel Based (Excel 2010 supported)
•MassHunter application exports data in XML and graphics files
•Templates define report formatting
•Over 100 shipping report templates
•Reports can be altered for desired information & appearance
•Customization using Excel features (function, formatting, code)
•Computer Based Training for report customization by users
•Some customization available through Agilent

Agilent Confidential36 January 8, 2013
Application Notes

Flexibility: Performance and Budget
Page 37
Lowest PricePerformance MeetsMethod Requirement
5977E Turbo MS5977E Diff MS
7820A Stainless source
HighestGC Performance& MS Performance
5977A EI5977A EI/CI
7890B GC Extractor source DS42i
Balance of Price, GC performance,& MS performance
5977A Turbo MS5977A Diff MS
7890B GC Inert source

Agilent Confidential38 January 8, 2013
Maintenance and Support Issues

January 8, 2013Agilent Confidential
39
Q&A Discussion