1 / 9 When things get rough you need new stuff William Lipps Analytical & Measuring Instrument...

30
1 / 9 When things get rough you need new stuff William Lipps Analytical & Measuring Instrument Division July, 2015

Transcript of 1 / 9 When things get rough you need new stuff William Lipps Analytical & Measuring Instrument...

Page 1: 1 / 9 When things get rough you need new stuff William Lipps Analytical & Measuring Instrument Division July, 2015.

1 / 9

When things get rough you need new stuffWilliam LippsAnalytical & Measuring Instrument DivisionJuly, 2015

Page 2: 1 / 9 When things get rough you need new stuff William Lipps Analytical & Measuring Instrument Division July, 2015.
Page 3: 1 / 9 When things get rough you need new stuff William Lipps Analytical & Measuring Instrument Division July, 2015.

It’s out there

Page 4: 1 / 9 When things get rough you need new stuff William Lipps Analytical & Measuring Instrument Division July, 2015.

All methods begin with an idea

It’s

co

min

g to

get yo

u

Page 5: 1 / 9 When things get rough you need new stuff William Lipps Analytical & Measuring Instrument Division July, 2015.

Are you ready?

Page 6: 1 / 9 When things get rough you need new stuff William Lipps Analytical & Measuring Instrument Division July, 2015.

How will you detect it, and are your methods fast enough?

Page 7: 1 / 9 When things get rough you need new stuff William Lipps Analytical & Measuring Instrument Division July, 2015.
Page 8: 1 / 9 When things get rough you need new stuff William Lipps Analytical & Measuring Instrument Division July, 2015.

MALDI-TOF Mass Spectrometry can identify sub-species in under 2 minutes

Page 9: 1 / 9 When things get rough you need new stuff William Lipps Analytical & Measuring Instrument Division July, 2015.

Red lines indicating a spectrum match

Page 10: 1 / 9 When things get rough you need new stuff William Lipps Analytical & Measuring Instrument Division July, 2015.

Algae is toxic and it Kills

Page 11: 1 / 9 When things get rough you need new stuff William Lipps Analytical & Measuring Instrument Division July, 2015.

LCMSMS Analysis of Microcystins

Page 12: 1 / 9 When things get rough you need new stuff William Lipps Analytical & Measuring Instrument Division July, 2015.

Polar pesticides and herbicides are difficult by GC

Page 13: 1 / 9 When things get rough you need new stuff William Lipps Analytical & Measuring Instrument Division July, 2015.

Analyze pesticides and herbicides by LCMSMS, with very little sample prep

Page 14: 1 / 9 When things get rough you need new stuff William Lipps Analytical & Measuring Instrument Division July, 2015.

Analyze pesticides and herbicides by LCMSMS, with very little sample prep

Page 15: 1 / 9 When things get rough you need new stuff William Lipps Analytical & Measuring Instrument Division July, 2015.

We can analyze hundreds more pesticides with high selectivity and sensitivity by GCMSMS

Page 16: 1 / 9 When things get rough you need new stuff William Lipps Analytical & Measuring Instrument Division July, 2015.

Methods can retain full scan capability and add MRM for greater selectivity and sensitivity

11.0 11.5 12.0 12.5 13.0 13.5 14.0 14.5 15.0 15.5 16.0 16.5 17.0 17.5

1.0

2.0

3.0

4.0

(x1,000,000)

Scan Chromatogram

MRM Chromatogram

13.50 13.75 14.00 14.25

0.25

0.50

0.75

1.00

(x10,000)

279.00>204.90279.00>222.90

0 50 100 150 200 250 300 350 400

0

25

50

75

100

%

97

223

16265

27911725117359 135 203

259 341397

365305

Qualification Quantification

Page 17: 1 / 9 When things get rough you need new stuff William Lipps Analytical & Measuring Instrument Division July, 2015.

Analysis of solid waste for metals requires acid digestion and instrumental analysis,

Page 18: 1 / 9 When things get rough you need new stuff William Lipps Analytical & Measuring Instrument Division July, 2015.

Or,

Page 19: 1 / 9 When things get rough you need new stuff William Lipps Analytical & Measuring Instrument Division July, 2015.

And create new methods that use XRF

X-ray tube

Primary X-rays

Horizontal axis: Energy (keV) = Type of element

Vertical axis: X-ray intensity (cps/uA) = Concentration (ppm)

Pb Cd

CrAl

AlPb

CrCd

23.110kev

10.552keV

5.412keV

1.487keV

Al

Cr

Pb

Cd

– cps/uA

– cps/uA

– cps/uA

– cps/uA

Fluorescent X-rays

Detector

Analysis sample

Page 20: 1 / 9 When things get rough you need new stuff William Lipps Analytical & Measuring Instrument Division July, 2015.

20 / 920

An example of a whole rock quantitative analysis of cement

Na-S SrK-Zn

Peak Profile of Cement Standard Substance

Sample Appearance

(Press-formed at 250 kN for 30 sec)

% MgO % Al2O3 % SO3 % CaO

XRF 1.75 3.95 21.9 69.6

CRM 1.93 3.88 22.4 67.9

Page 21: 1 / 9 When things get rough you need new stuff William Lipps Analytical & Measuring Instrument Division July, 2015.

Just place liquids, slurry samples, and emulsions in a sample cell

Sample cell, film, and 5 mL oil

Page 22: 1 / 9 When things get rough you need new stuff William Lipps Analytical & Measuring Instrument Division July, 2015.

Elements in Waste Oil (0, 10, 30, and 50 ppm of each element)

Overlaid Profiles of Heavy Elements in Waste Oil

30 ppm

Blank Sample

50 ppm

10 ppm

Page 23: 1 / 9 When things get rough you need new stuff William Lipps Analytical & Measuring Instrument Division July, 2015.

Foreign Matter Adhering to a Plastic Extruded Part

— F

e K

b—

Ni K

a

— C

r K

a

— C

r K

a

Mn

Kb

— T

i Ka

— T

i Kb

— N

i Kb

— Z

n K

a

— Z

n K

b

— M

o K

a

Foreign matter

Normal position

Overlaid Profiles of Foreign Matter (Red) and Normal Position (Blue)

— F

e K

a

Sample Appearance

Red circle: Foreign matterBlue circle: Normal position

Page 24: 1 / 9 When things get rough you need new stuff William Lipps Analytical & Measuring Instrument Division July, 2015.

Let’s reduce toxic chemicals

Page 25: 1 / 9 When things get rough you need new stuff William Lipps Analytical & Measuring Instrument Division July, 2015.

Replace toxic cadmium with reductase for NOx

Sample # Commercial Laboratory

Results, Analysis Method EPA 335.2 (mg

NO3+NO2-N/L)

Analysis by Reductase (mg NO3+NO2-N/L)

1 0.8 0.942 <0.1 0.053 <0.1 0.244 0.66 0.685 11.8 11.66 0.78 0.797 2.4 3.11

Page 26: 1 / 9 When things get rough you need new stuff William Lipps Analytical & Measuring Instrument Division July, 2015.

Should we continue with the Kjeldahl Method for TKN?

Page 27: 1 / 9 When things get rough you need new stuff William Lipps Analytical & Measuring Instrument Division July, 2015.

Or use HTCO methods and obtain near equal results with TKN

Page 28: 1 / 9 When things get rough you need new stuff William Lipps Analytical & Measuring Instrument Division July, 2015.

Technology is advancing faster than the methods

Page 29: 1 / 9 When things get rough you need new stuff William Lipps Analytical & Measuring Instrument Division July, 2015.

It’s time for some new stuff

• MALDI TOF – New, faster way to confirm bacteria

• LCMSMS – Emerging Contaminants not visible before

• GCMSMS – more sensitive, higher throughput

• XRF – no digestions, higher throughput

• NOx – safer, non toxic reagents

• TN – safer and higher throughput than TKN

Page 30: 1 / 9 When things get rough you need new stuff William Lipps Analytical & Measuring Instrument Division July, 2015.

Thank You, for more information contact me

[email protected]