07A – Multi-Tank Calibration€¦ · 07A – Multi-Tank Calibration 7A-10 Apollo System 21. Press...

11
07A – Multi-Tank Calibration Apollo System 7A-1 1. Divert hydraulic Flow from Fan 2. Adjust product diverters to Calibration setting 3. Insert the Calibration deflector. 4. Slide sample collection tray onto collector. 5. Adjust the transmissions by moving the locking pin from Direct Drive to Slow Speed Drive. (DIRECT DRIVE SHOWN) ENSURE THE TRACTOR IS NOT RUNNING WHILE REMOVING PINS!

Transcript of 07A – Multi-Tank Calibration€¦ · 07A – Multi-Tank Calibration 7A-10 Apollo System 21. Press...

  • 07A – Multi-Tank Calibration

    Apollo System 7A-1

    1. Divert hydraulic Flow from Fan

    2. Adjust product diverters to Calibration setting

    3. Insert the Calibration deflector.

    4. Slide sample collection tray onto collector.

    5. Adjust the transmissions by moving the locking pin from Direct Drive to Slow Speed Drive.

    (DIRECT DRIVE SHOWN) ENSURE THE TRACTOR IS NOT RUNNING WHILE REMOVING PINS!

  • 07A – Multi-Tank Calibration

    7A-2 Apollo System

    6. Press the Topcon logo for one second to load the Global Home screen menu.

    7. Navigate to the Calibration page.

    TAP QUICKLY TO

    LOAD SCREENS

  • 07A – Multi-Tank Calibration

    Apollo System 7A-3

    8. Follow the above step in sequence.

    1. ENABLE MANUAL

    SPEED (GREEN)

    2. SET YOUR DESIRED

    SPEED

    3. Use Arrows to Select

    Tank to be calibrated.

    4. SELECT GEAR RATIO:

    2 (DIRECT) or 16 (SLOW)

    5. Press Multi-Tank

    Calibration to Start the

    Wizard.

  • 07A – Multi-Tank Calibration

    7A-4 Apollo System

    9. Select Automatic Calibration.

    10. Follow the Prompt on the Calibration Wizard. Press the Yellow forward arrow.

  • 07A – Multi-Tank Calibration

    Apollo System 7A-5

    11. Check the target rates are set correctly.

    12. Turn on the Tanks you wish to calibrate by using the Number 1-2-3-4 on the Keypad. The color will

    change From Red (Off) to Orange (Ready State).

  • 07A – Multi-Tank Calibration

    7A-6 Apollo System

    13. Activate the metering by pressing the RUN/STOP button. The metering will then engage and

    distribute the product into the sample collector trays.

    14. The Estimated Weight will count continuously as product is collected into the Sample Collector.

    Keep an eye on the collector boxes, fill until roughly ¾ full.

    Keep all hands and personal

    clear from the metering

    systems, remember multiple

    tanks are now live and are

    ready to engage.

  • 07A – Multi-Tank Calibration

    Apollo System 7A-7

    15. When the sample trays are nearly Full Press the Number keys 1-2-3-4 to stop the Tanks from

    metering any additional product. When All Tanks are finished Press the RUN/STOP button.

    NOTE: You may stop any tank early by simply pressing the Number Key.

    Notice how the Tank LED status is RED = OFF

    16. Remove the Collector Trays and Weigh the Product using the provided scale.

    22.70 lbs.

  • 07A – Multi-Tank Calibration

    7A-8 Apollo System

    17. Write down Tank scale weights and return to the tractor cab.

    18. Return to the monitor, Press Next to Proceed.

  • 07A – Multi-Tank Calibration

    Apollo System 7A-9

    19. Notice the estimated weights. Now Enter the Actual recorded weight in the weight windows.

    20. Proceed by pressing the Next icon.

    Press here to enter the

    weights from the scale

  • 07A – Multi-Tank Calibration

    7A-10 Apollo System

    21. Press the Green Saved Icon and then the Green Accept Check mark to save the Calibration factor.

    22. It is recommends to repeat the Calibration procedure 2-3 additional times to fine tune and verify

    the calibration factors are accurate.

    Confirm the Cal factor by

    pressing the Accept Icon.

  • 07A – Multi-Tank Calibration

    Apollo System 7A-11

    NOTES: