Film Dosimetry

13/2/2011

Page 2: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

Introduction

2

Page 3: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

In the United States, three types of dosimeters can be used to measure the “dose of record:”

• Film

Introduction

3

• Thermoluminescent dosimeters

• Optically stimulated luminescent dosimeters

Page 4: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

Film dosimeters are most commonly employed to evaluate personnel exposures to x-rays.

Introduction

4

Hence, film dosimetry is often used in dentistry, veterinary practice, medicine and universities.

Page 5: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

Over time, an exposure to light or ionizing radiation can change the color of some materials.

Silver bromide is very susceptible to this

Introduction

5

Silver bromide is very susceptible to this phenomenon. The exposure to light or ionizing radiation changes the silver bromide, a yellow-white salt, to metallic silver which is black.

Certain chemicals can speed up (catalyze) this color change.

Page 6: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

Introduction

E l i E l i

6

Support Support

Emulsion Emulsion

Emulsion

SINGLE EMULSION

DOUBLE EMULSION

Page 7: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

The emulsion consists of a gelatinous matrix in which silver bromide (AgBr) crystals are suspended. The properties of the film depend on the size (ca. 1 um), shape, and number of these crystals (ca. 6 x 109 AgBr grains per cc). Some silver iodide (AgI) crystals are also present.

Introduction

7

crystals are also present.

Support

Gelatinous Matrix

Page 8: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

The silver bromide crystals have defects that contain groups of positively charged silver ions (Ag+). We will refer to these as “sensitivity specks.”

Introduction

8SILVER BROMIDE (AgBr) CRYSTAL

Sensitivity Specks

Page 9: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

The highest energy electrons in the silver bromide crystal occupy a range of energies known as the Valence Band.

Introduction

9

Valence Band

e-e-

e- e-e-e- e-

e- e- e-e-

Page 10: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

The conduction band is a higher energy level normally empty of electrons. If an electron were in the Conduction Band, the electron would be mobile.

Introduction

Conduction Band

10

Valence Band

e-e-

e- e-e-e- e-

e- e- e-e-

Page 11: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

The range of energies between the Valence and Conduction bands is the Band Gap. If the crystal were pure, electrons could not occupy the Band Gap.

Introduction

Conduction Band

11

Valence Band

Band Gap

e-e-

e- e-e-e- e-

e- e- e-e-

Page 12: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

A sensitivity speck (a group of Ag+ ions) has electron vacancies. If an electron filled one of these vacancies, it would have an energy in the Band Gap.

Introduction

Conduction Band

12

Valence Band

Band Gap

e-e-

e- e-e-e- e-

e- e- e-

+

e-

Page 13: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

When radiation energy is absorbed by a silver bromide crystal, some of the electrons are promoted from the Valence Band to the Conduction Band.

Once in the Conduction Band, these electrons are mobile Some will move to the sensitivity specks and

Introduction

13

mobile. Some will move to the sensitivity specks and fill the electron vacancies.

Page 14: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

Introduction

Conduction Band

As a result of an exposure to radiation, an electron in the Valence Band is promoted to the Conduction Band.

14

Valence Band

Band Gap

e-e-

e- e-e-e- e-

e- e- e-

Sensitivity Speck

(Ag+ ion)

+

e-

Page 15: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

If an electron reaches a “sensitivity speck” the latter is converted into a “latent image” that consists of neutral silver atoms, i.e., silver metal.

Introduction

Conduction Band

15

Valence Band

Band Gap

e-e-

+ e- e-e-e- e-

e- e- e-

Latent Image

(Ag atom)

e-

Page 16: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

This shows two electrons moving to “sensitivity specks.” The greater the radiation energy deposited in the crystal, the greater the number of electrons moving to the sensitivity specks.

Introduction

16

SILVER BROMIDE (AgBr) CRYSTAL

e-

e-

Page 17: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

Two sensitivity specks have now been converted to “latent images.”

Introduction

17

SILVER BROMIDE (AgBr) CRYSTAL

Latent Image

Page 18: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

The silver ions at the latent image have been chemically reduced, i.e., converted to metallic silver.

Introduction

18

SILVER BROMIDE (AgBr) CRYSTAL

Page 19: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

Film Processing

19

Page 20: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

After it has been exposed to radiation, the photographic film is processed.

The processing consists of three or four steps:

1 Submersion of the film in a developing solution

Film Processing

20

1. Submersion of the film in a developing solution

2. Submersion of the film in a stop bath

3. Submersion of the film in a fixative solution

4. Rinsing the film in water.

Page 21: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

The developer solution contains chemicals that speed up the reduction of the silver bromide.

If the radiation produced 10 or so atoms of metallic silver (reduced Ag+ ions) in a crystal, the developer can catalyze the complete conversion (reduction) of

Developer

21

can catalyze the complete conversion (reduction) of the AgBr crystal into a grain of metallic silver.

Each interaction of a 10 keV photon might produce one “developable crystal. The interaction of a 1 MeV photon might produce 5-10 “developable” crystals.

Page 22: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

The stop bath, usually a solution of dilute acetic acid, accomplishes two purposes:

– It stops the action of the developer

Stop Bath (optional)

22

– It minimizes the contamination of the fixative by the developer

Page 23: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

The purpose of the fixative (containing sodium thiosulfate) is to dissolve any remaining unreduced silver bromide crystals. Unless this is done, the film would darken following a subsequent exposure to light. As the name implies, the fixative stabilizes the “image.”

Fixative

23

image.

Once the film is in the fixative, it can be exposed to ambient light.

As a rule, used fixative is collected so that the silver can be recycled.

Page 24: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

The purpose of the rinse (e.g., 30-40 minutes in running water) is to remove the fixative solution.

After rinsing, the film should be dried in such a way as to avoid drying spots.

Rinse

24

Page 25: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

To ensure a consistent relationship between the darkening of the film and the absorbed dose:

• The times that the film is in the developer (e.g., 10 min) and fixer (e.g., 10-15 min) must not change.

Quality Control

25

• The temperature of the developer (e.g., 20 ºC) must be consistent.

• The developer and fixer solutions should be fresh.

• Agitation of the film during developing (e.g., a few seconds every minute) should be consistent.

Page 26: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

Assessing the Dose

26

Page 27: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

The greater the radiation dose, the darker the film will be after processing.

Until the 1950s, the darkening of the film was often assessed by eye. One procedure was to try to read a newspaper through the processed film If the

Assessing the Dose

27

a newspaper through the processed film. If the newspaper could be read, the dose was considered acceptable.

In the mid 1940s, electronic instrumentation (densitometers) began to be used to quantify the darkening of the film.

Page 28: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

A densitometer is a device that is used to measure the darkening of the film. The following diagram illustrates a typical densitometer.

Densitometer

12

3Photomultiplier

28

Optical Density

40

Filter/Lens

Film

Light Source

Photomultiplier Tube (PMT)

Page 29: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

A photomultiplier tube is used to measure the amount of light that gets through the film.

The process involves comparing the intensity of the light that gets through the exposed film with the intensity of light that gets through unexposed film

Densitometer

29

intensity of light that gets through unexposed film.

The densitometer reads out in units of “optical density” which ranges from 0 to 4 or so.

Page 30: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

The “optical density” is calculated as follows.

Optical Density

30

O.D. is the “optical density”

I0 is intensity of light that gets through unexposed film

Ix is intensity of light that gets through the exposed film

Page 31: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

If ten times more light gets through the unexposed film than gets through the exposed film, the optical density is 1.

If one hundred times as much light gets through the unexposed film as gets through the exposed film

Optical Density

31

unexposed film as gets through the exposed film, the optical density is 2.

If one thousands times as much light gets through the unexposed film as gets through the exposed film, the optical density is 3.

Page 32: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

The optical density of film exposed to different doses is measured. Optical density is the plotted as a function of absorbed dose.

Calibration Curve

Useful Range

32

OD

Absorbed dose (rads/Gy)

Page 33: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

The optical density of an emulsion for a given exposure (the sensitivity) depends on several things:

– Thickness of emulsion

Calibration Curve

33

– Density of AgBr crystals

– Density of AgI crystals

– Size and shape of crystals (grains)

– Nature of defects/impurities in crystals

Page 34: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

Calibration CurveA high sensitivity emulsion, known as a “fast emulsion,” is better able to assess low doses.A low sensitivity emulsion, known as a “slow emulsion,” is better able to assess high doses.

34

OD

Absorbed dose (rads/Gy)

Fast Emulsion

Slow Emulsion

Page 35: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

Kodak Film Types for Therapeutic Radiology

Film Type Range Saturation

PPL0.25 – 5 rads

(0.0025-0.05 Gy)10 rads (0.1 Gy)

1 15 d

35

XTL1 – 15 rads

(0.01-0.15 Gy)30 rads (0.3 Gy)

XV-25 – 100 rads

(0.05-1 Gy)200 rads (2 Gy)

EDR225 – 400 rads

(0.25-4 Gy)700 rads (7 Gy)

Page 36: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

Kodak Film for Personnel Monitoring

Kodak Type 2 Film

Approximate useful Range

30 mrems - 2500 rads

B t R

36

Beta Response (maximum)

1.71 – 5 MeV

Photon Response 5 keV – 3 MeV

Page 37: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

Kodak Type 2 Film for Personal Monitoring

Support

Fast Emulsion

Slow Emulsion

Light tight packet

37

So that the two sides can be easily distinguished, the fast emulsion has a matte surface while the slow emulsion has a glossy surface.

Page 38: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

Although no longer used, this film was once commonly employed to estimate neutron doses.

Thermal neutrons were absorbed by nitrogen in the film. The resulting n, p reaction produced proton tracks in the developed emulsion

Kodak Type A NTA Film for Neutrons

38

tracks in the developed emulsion.

Fast neutrons with energies above 500 keV produced tracks due to proton recoil, i.e., elastic scattering collisions with hydrogen nuclei in the film.

The film was insensitive to neutrons with epithermal energies up to 500 keV.

Page 39: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

Fast

NeutronSlow

NeutronFast

NeutronSlow

Neutron

Cadmium

Kodak Type A NTA Film for Neutrons

39

Support

ProtonTrack

ProtonTrack

ProtonTrack

Emulsion

Page 40: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

The tracks were counted under a microscope and the track density was related to the absorbed dose.

A cadmium filter was used to distinguish the number of proton tracks produced by fast neutrons from the number of tracks produced by slow

Kodak Type A NTA Film for Neutrons

40

from the number of tracks produced by slow neutrons.

Page 41: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

Film Dosimeter Badges

41

Page 42: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

The film holder (aka badge) usually has an open “window.”

The film in the window area responds to beta

Beta Dose

42

particles as well as x-rays and/or gamma rays.

The film covered by the plastic film holder only responds to x-rays and gamma rays.

Page 43: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

Energy Dependence of Film Response

The sensitive component of the film dosimeter, the silver bromide crystals, contains a high Z material: silver (Ag).

For a given exposure (e.g., 1 rad), the optical density is greater for low energy photons (e g 100 keV) than

43

is greater for low energy photons (e.g., 100 keV) than for higher energy photons (e.g., 662 keV).

Page 44: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

Energy Dependence of Film Response

OD

Optical density as a function of photon energy for a given exposure (e.g., 1 rad)

44

OD

Photon Energy (keV)10 100 1000

Page 45: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

Energy Dependence of Film Response

This means that the calibration factor, which relates the optical density to the absorbed dose, varies with the photon energy. As such, film dosimeters must use some method to estimate the energy of the photons to which they are exposed.

45

They do so by analyzing the ratios of the optical density of the film underneath metal filters with different atomic numbers (e.g., Al, Cu, Pb).

Page 46: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

Window

Film Packet

Typical Film Badge Design

Cu Filter

46Side ViewFront View

Cu Filter

Al Filter

Pb/Sn FilterPb/Sn Filter

Page 47: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

In some cases, the filters on the front of the badge and those on the back have different shapes (e.g., square vs round). In this case, the image of the filter on the developed film can identify whether the exposure was from the front or back.

Exposure Direction

47Exposure from front,

square imageExposure from back,

round image

Film Film

Page 48: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

If the exposure occurred for a very short time, the image of the filters on the developed film should have sharp well defined edges. If the exposure was prolonged, the images should be less distinct.

Acute vs Prolonged Exposure

48Acute Exposure Prolonged Exposure

Page 49: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

An irregular unusual image might indicate the the badge (or the film) had become contaminated.

Contaminated Badge

49

Contaminated Badge/Film

Page 50: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

Advantages and Disadvantages of Film Dosimetry

50

y

Page 51: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

Advantages of Film Dosimetry

• The dosimeter itself serves as a permanent record

• The film can be reread

• Film is available in a wide range of sizes

51

g

• The photographic image can indicate the presence of contamination on the badge

• The photographic image can distinguish acute short term exposures from chronic exposures.

Page 52: 0751 - H122 - Basic Health Physics - 20 - Film Dosimetry.“image.” Fixative 23 Once the film is in the fixative, it can be exposed to ambient light. As a rule, used fixative is

Disadvantages of Film Dosimetry

• The response of film is very dependent on the energy of the photons.

• Accurate estimations of the dose require careful and consistent processing of the film.

52