07 NEC ELEC Traceability Chart 1 20-Mar-09 · 75/107 M. 11, Paholyothin Rd., Klong 1, Klong Luang,...
Transcript of 07 NEC ELEC Traceability Chart 1 20-Mar-09 · 75/107 M. 11, Paholyothin Rd., Klong 1, Klong Luang,...
![Page 1: 07 NEC ELEC Traceability Chart 1 20-Mar-09 · 75/107 M. 11, Paholyothin Rd., Klong 1, Klong Luang, Pathumthani 12120 Tel. (66) 2-529-2460, Fax. (66) 2-529-2466 Traceability Chart](https://reader036.fdocuments.net/reader036/viewer/2022071112/5fe7f408f559c713a92ab478/html5/thumbnails/1.jpg)
National Standard
NEC's HighestStandards
NEC's WorkingStandards
Customer'sEquipment
Remark: * ISO/IEC 17025 accredited scopes by Thai Laboratory Accreditation Scheme (Thai Industrial Standards Institute, Ministry of Industry).
FEZ-0009-G-Form-03/V5 /01/04/08
Calibration CenterNEC Corporation (Thailand) Ltd.75/107 M. 11, Paholyothin Rd.,Klong 1, Klong Luang, Pathumthani 12120Tel. (66) 2-529-2460, Fax. (66) 2-529-2466
Traceability ChartPrepared by:
(TM)Date: 20-Mar-09
Approved by:
(TM Leader)Date: 20-Mar-09
Scope: Electrical Calibration (1) (Voltage, Current, Power)
CalibrationNo. 0132
Voltage/Current Meters (Analog/Digital): - * DCV Meters (0~1kV) - * ACV Meters (Up~1kV, 10Hz~30MHz) - * DCA Meters (0~100A) - * DCA Clamp Meter (0~1kA) - * ACA Meters (Up~50A, 10Hz~100kHz) - * ACA Clamp Meter (Up~1kA, 45~440Hz - * Digital Electrometer (1pA~20mA, 0~1kV) - * DC/AC Cut-off Current Meter (0~100mA, 50~60Hz)
Watt Meters/Sources (Analog/Digital): - * DCW Meters (1mW~20kW) - * ACW Meters (1mW~20kW, 45~65Hz, PF 0.3~1) - * Watt Meter With Clamp (1mW~20kW) - * Power Hi Testers (DCV, DCA, ACV, ACA, DCW, ACW) - DCW Source (1mW~20kW) - ACW Source (1mW~20kW, 10Hz-10kHz)
Voltage/Current Sources (Analog/Digital): - * DCV Calibrators/Sources (0~1kV) - * ACV Calibrators/Sources (Up~1kV, 10Hz-30MHz) - * DCA Calibrators/Sources (0~200A) - * ACA Calibrators/Sources (Up~50A, 10Hz-30kHz) - * DC Power Supplies (DCV, DCA) - * AC Power Supplies (ACV, ACA, Freq.) - DC/AC Cut-Off Current Source (Withstanding Testers)
Working Standard Equipment: Functions / Ranges: - DCV Standard Cell, Fluke 732B - Multi-function Calibrator, Fluke 5700A - Multi-product Calibrator, Fluke 5520A - Multi-product Calibrator, Fluke 5500A - DC V/A Standard, Yokogawa 2560 - AC V/A Standard, Yokogawa 2558 - Calibrator & Source, Keithley 263 - Multi-function Transfer Standard, Wavetek 4950 - Digital Multimeter, HP 3458A (Opt-002) - Digital Multimeter, Fluke 8846A - Digital Multimeter, Agilent 34411A, 34401A - Electrometer, Keithley 617 - Metal Film Resistor Set, Fluke - AC/DC Shunt, Wavetek 4953 - Metal Clad Resistor Set, PCN - Standard Resistor Set, Yokogawa 27X2's - Standard Shunt, Yokogawa 2743 - Standard Resistor, Advantest TR's series - DC Power Supply, Kikusui PAK10-100 - Electronic Load, Kikusui PLZ's series - AC/DCA Cut-off Meter, Kiksui TOS-1200
- DCV 10V, 1.018V - DCV (0~1kV), DCA (0~2.2A), ACV (Up~1kV, 10Hz~1MHz), ACA (Up~2.2A, 10Hz~10kHz) - DCV (0~1kV), DCA (0~20A), ACV (Up~1kV, 10Hz~500kHz), ACA (Up~20A, 10Hz~30kHz) - DCV (0~1kV), DCA (0~10A), ACV (Up~1kV, 10Hz~500kHz), ACA (Up~10A, 10Hz~10kHz) - DCV (0~1kV), DCA (0~30A) - ACV (Up~1kV, 40Hz~400Hz), ACA (Up~50A, 40Hz~400Hz) - DCV (0~20V), DCA (0~20mA) - DCV (0~1kV), DCA (0~1A), ACV (Up~1kV, 10Hz~1MHz), ACA (Up~1A, 10Hz~30kHz) - DCV (0~1kV), DCA (0~1A), ACV (Up~0.7kV, 10Hz~10MHz), ACA (Up~1A, 10Hz~100kHz) - DCV (0~1kV), DCA (0~10A), ACV (Up~1kV, 10Hz~500kHz), ACA (Up~10A, 10Hz~30kHz) - DCV (0~1kV), DCA (0~3A), ACV (Up~0.7kV, 10Hz~500kHz), ACA (Up~3A, 10Hz~30kHz) - DCV (0~200V), DCA (0~20mA) - ACA (AC/DC Diff, 3µA~10mA, 10Hz~100kHz) - ACA (AC/DC Diff, 10mA~10A, 10Hz~100kHz) - DC/ACA (0~200A, DC~60Hz) - DCA (0~20A) - DCA (20~100A) - DCA (10pA~10nA) - DCA (0~100A) - DCV (0~500V), DCA (0~140A), DCW (0~1000W) - DC/ACA Cut-Off (0~100mA, DC~60Hz)
Working Standard Equipment: Functions / Ranges: - DCV Standard Cell, Fluke 732B - Multi-function Calibrator, Fluke 5720A - Amplifier, Fluke 5725A - AC Measurement System, Fluke 5790A+WB - Digital Multimeter, Agilent 3458A (Opt-002) - Standard Resistor Set, Fluke 742A's - Standard Resistor Set, IET SRX's series - Metal Film Resistor Set, Fluke - AC Shunt Set, Fluke A40's - AC Shunt Guidline 7320 - Primary AC Shunt HOLT HCS-1
- DCV 10V, 1.018V - DCV (0~1kV), DCA (0-2.2A), ACV (0-1kV, 10Hz-1MHz), ACA 0-2.2A (10Hz-10kHz) - ACV (300~1kV, 40Hz-100kHz), DCA (2.2-11A), ACA (2.2-11A, 10Hz-10kHz) - ACV (2mV~1kV, 10Hz-1MHz), AC-DC Diff (2mV-1kV, 10Hz-1MHz), ACV (Wide-Band, 50Ω, 2mV-7V, 10Hz-30MHz) - DCV (0~1kV), DCA (0-1A), ACV (0-0.7kV, 10Hz-10MHz), ACA (0-1A, 10Hz-100kHz) - DCA (0~200mA) - DCA (0A~20A) - ACA (AC/DC Diff, 3µA~10mA, 10Hz~100kHz) - ACA (AC/DC Diff, 10mA~5A, 10Hz~30kHz) - ACA (AC/DC Diff, 5A~10A, 10Hz~30kHz) - ACA (AC/DC Diff, 10A~50A, 10Hz~30kHz)
National Institute of Metrology (Thailand), NIMT
![Page 2: 07 NEC ELEC Traceability Chart 1 20-Mar-09 · 75/107 M. 11, Paholyothin Rd., Klong 1, Klong Luang, Pathumthani 12120 Tel. (66) 2-529-2460, Fax. (66) 2-529-2466 Traceability Chart](https://reader036.fdocuments.net/reader036/viewer/2022071112/5fe7f408f559c713a92ab478/html5/thumbnails/2.jpg)
National Standard
AccreditedLaboratories
NEC's HighestStandards
NEC's WorkingStandards
Customer'sEquipment
Remark: * ISO/IEC 17025 accredited scopes by Thai Laboratory Accreditation Scheme (Thai Industrial Standards Institute, Ministry of Industry).
FEZ-0009-G-Form-03/V5 /01/04/08
Traceability ChartPrepared by:
(TM)
Date: 20-Mar-09
Approved by:
(TM Leader)
Date: 20-Mar-09
Scope: Electrical Calibration (2) (High Voltage, Resistance)
High Volt. Meters/Sources: - * DC/AC High Volt. Meters - * DC/AC High Volt. Sources - * Withstanding Volt. Testers/ Electrical Safety Testers - Electrostatic Field Meters - High Voltage Probes - High Voltage Dividers - Impulse Testers Range: DCV/ACV: 0.5kV~10kV, 50Hz~60Hz
DC Resistance Meters: - * DC Resistance Meters - * Resistance Bridge - * mΩ Testers - * MΩ Testers - * Insulation Testers - * Super MΩ Meters - Wristrap/Shoes Testers - Surface Resistance Testers Range: DCR: 0~10GΩ
DC Resistance Sources: - * DC Resistance Calibrators - * DC Resistance Sources - * DC Standard Resistors - * DC Decade Resistance Boxes - * DC Resistors
Range: DCR: 0~10GΩ
DC Electrometer/Sources: - * DC Electrometers - * Ultra High Res. Meters - * DC High Resistance Sources - * DC Giga/Tera Ohm Meters - * DC Giga/Tera Ohm Resistors - * DC Giga/Tera Ohm Decade Boxes
Range: DCR: 1MΩ~1TΩ
AC Resistance Meters/Sources: - AC Resistance Meters (LCR Meters) - AC Low Ohm Testers - AC Ground Bond Testers - AC Resistance Sources - AC Resistors
Range: ACR: 1mΩ~100MΩ (10Hz~13MHz)
Standard Equipment: - DC/AC High Volt. Digital Meter, Kikusui 149-10A - Electrostatic Meter, Trek 347 - High Voltage Probe, Tektronix P6015A - Withstanding Volt. Tester, Kikusui TOS5101 - Digital Multimeter, Agilent 34411A, 34401A Range: DCV/ACV: 0.5kV~10kV, 50Hz~60Hz
Standard Equipment: Functions/Ranges:- Multi-function Calibrator, Fluke 5700A- Multi-product Calibrator, Fluke 5520A- Multi-product Calibrator, Fluke 5500A- Digital Multimeter, HP 3458A (Opt-002)- Digital Multimeter, Agilent 34411A, 34401A- Digital Multimeter, Fluke 846A- Standard Resistors, Yokogawa 2792's Series- Calibrator & Source, Keithley 263- Electrometer, Keithley 617- Metal Clad Resistor Set, PCN- Decade Resistance Box Set
- DCR (0~100MΩ)- DCR (0~1GΩ)- DCR (0~330MΩ)- DCR (0~1GΩ)- DCR (0~1GΩ)- DCR (0~1GΩ)- DCR (1m~100kΩ)- DCR (0~100GΩ)- DCR (0~100GΩ)- DCR (1mΩ~5Ω)- DCR (0~1TΩ)
Standard Equipment: - Precision LCR Meter, HP 4284A - LF Impedance Analyzer, HP 4192A - LCR Standard, Sun Jem 6100A - Calibration Standard, HP 16074A - Standard AC Resistor Set, Electrohm - Metal Clad Resistor Set, PCN
Range: ACR (1mΩ~100MΩ, 10Hz-13MHz)
Standard Equipment/Ranges: - High Voltage Power Amplifier, Trek 10/10B - Multi-Product Calibrator, Fluke 5520A Range: DCV/ACV: 0.5kV~10kV, 50Hz~60Hz
Standard Equipment: Functions/Ranges:- Multi-function Calibrator, Fluke 5720A- Digital Multimeter, Agilent 3458A (Opt-002)- Standard Resistor Set, Fluke 742A's- Standard Resistor Set, IET SRX's series
- DCR (0~100MΩ)- DCR (0~1GΩ)- DCR (0~10kΩ)- DCR (0~10MΩ)
Standard Equipment/Ranges: - Precision LCR Meter, HP 4284A - Four-Terminal Pair Resistors, HP 42030A Range: ACR: 1mΩ~100MΩ, 10Hz~13MHz
Thai Airway International Public Co., Ltd. (TLAS Accredited No. 0003)
Agilent Technologies (Japan)(JCSS no.: 0048)
National Institute of Metrology (Thailand), NIMTCSIRO National Measurement
Laboratory (NML), AustraliaNational Metrology Institute of
Japan (NMIJ), Japan
CalibrationNo. 0132
Calibration CenterNEC Corporation (Thailand) Ltd.75/107 M. 11, Paholyothin Rd.,Klong 1, Klong Luang, Pathumthani 12120Tel. (66) 2-529-2460, Fax. (66) 2-529-2466
![Page 3: 07 NEC ELEC Traceability Chart 1 20-Mar-09 · 75/107 M. 11, Paholyothin Rd., Klong 1, Klong Luang, Pathumthani 12120 Tel. (66) 2-529-2460, Fax. (66) 2-529-2466 Traceability Chart](https://reader036.fdocuments.net/reader036/viewer/2022071112/5fe7f408f559c713a92ab478/html5/thumbnails/3.jpg)
National Standard
Accreditedlaboratories
NEC's HighestStandards
NEC's WorkingStandards
Customer'sEquipment
Remark: * ISO/IEC 17025 accredited scopes by Thai Laboratory Accreditation Scheme (Thai Industrial Standards Institute, Ministry of Industry)
FEZ-0009-G-Form-03/V5 /01/04/08
Calibration CenterNEC Corporation (Thailand) Ltd.75/107 M. 11, Paholyothin Rd.,Klong 1, Klong Luang, Pathumthani 12120Tel. (66) 2-529-2460, Fax. (66) 2-529-2466
Traceability ChartPrepared by:
(TM)Date: 20-Mar-09
Approved by:
(TM Leader)Date: 20-Mar-09
Scope: Electrical Calibration (3) (Capacitances, Inductances)
Capacitance Meters: - * 2-Terminal Type LCR Meters (Capacitance) - * 4-Terminal Type LCR Meters (Capacitance) - * Digital Multimeters (Capacitance) - * Capacitance % Meters Range: 1pF~110mF, 10Hz~13MHz
Capacitance Sources: - * 2-Terminal Type Standard Capacitors - * 4-Terminal Type Standard Capacitors - * Capacitance Calibrators/Sources - * Decade Capacitance Boxes - * Capacitors Range: 1pF~110mF, 10Hz~13MHz
Inductance Meters: - * 2-Terminal Type LCR Meters (Inductance) - * 4-Terminal Type LCR Meters (Inductance) - * Digital Multimeters (Inductance) - * Inductance Meters Range: 100µH~1H, 100Hz~100kHz
Inductance Sources: - * Standard Inductors - * Inductance Sources - * Decade Inductance Boxes - * Inductors Range: 1µH~10H, 100Hz~100kHz
Standard Equipment: Functions/Ranges:
- Precision LCR Meter, HP 4284A- LF Impedance Analyzer, HP 4192A- Decade Inductor, ANDO AM3301
- 10nH ~ 1kH (100Hz ~ 100kHz)- 10nH ~ 100kH (100Hz ~ 100kHz)- 1mH ~ 1H (100Hz ~ 100kHz)
Standard Equipment: Functions/Ranges:- 4-T Standard Capacitor Set, HP16380A, 16380C- Multi-product Calibrator, Fluke 5520A- Multi-product Calibrator, Fluke 5500A- Precision LCR Meter, HP 4284A- LF Impedance Analyzer, HP 4192A- LCR Standard, Sun Jem 6100A- Standard Capacitor Set, Shoshin- Decade Capacitor, HP 4440B- Precision Decade Capacitor General Radio 1413
- 1pF~1µF- 0.19nF~110mF- 0.33nF~1.1mF- 1pF~100mF- 1pF~100mF- 100pF~100mF- 30pF~60pF- 40pF~1.1µF- 1pF~1µF
Standard Equipment/Ranges: 4-Terminal Standard Capacitor, Quadtech 1417 Range: 1µF~100mF, 100Hz,120Hz,1kHz
Standard Equipment/Ranges: 4-Terminal Standard Capacitor Set, HP16380A, 16380C Range: 1pF~1µF, 10Hz~13MHz
Standard Equipment/Ranges: - Precision LCR Meter, HP4284A 10nH~1kH, (100Hz~100kHz) - Standard Self Inductor Set, Ando RS's Series 100µH~1H, (100Hz~10kHz)
Agilent Technologies (Japan)(JCSS no.: 0048)
National Metrology Institute of Japan (NMIJ), Japan
National Institute of Metrology (Thailand), NIMT
CalibrationNo. 0132
![Page 4: 07 NEC ELEC Traceability Chart 1 20-Mar-09 · 75/107 M. 11, Paholyothin Rd., Klong 1, Klong Luang, Pathumthani 12120 Tel. (66) 2-529-2460, Fax. (66) 2-529-2466 Traceability Chart](https://reader036.fdocuments.net/reader036/viewer/2022071112/5fe7f408f559c713a92ab478/html5/thumbnails/4.jpg)
National Standard
AccreditedLaboratories
-
NEC's Highest - Standards
-
NEC's WorkingStandards
Customer'sEquipment
Remark: * ISO/IEC 17025 accredited scopes by Thai Laboratory Accreditation Scheme (Thai Industrial Standards Institute, Ministry of Industry).# No traceability to national standard
FEZ-0009-G-Form-03/V5 /01/04/08
22-Nov-07 Calibration CenterNEC Corporation (Thailand) Ltd.75/107 M. 11, Paholyothin Rd.,Klong 1, Klong Luang, Pathumthani 12120Tel. (66) 2-529-2460, Fax. (66) 2-529-2466
Traceability ChartPrepared by:
(TM)Date: 24-Mar-09
Approved by:
(TM Leader)Date: 24-Mar-09
Scope: Electrical Calibration (4) (Frequency, RF Power)
Frequency Meters/Sources: - * Frequency / Universal Counters - * Microwave / Time Interval Counters - * Frequency Standards / Quartz Testers - * Frequency Sources from Other Instrument - * Digital Multimeters (Frequency) / Frequency Meters - Timers / Stopwatches - Tachometers / Stroboscopes Range: 1Hz~40GHz
RF Power Meters: RF Power Sources:Example of Instrument (RF Measurement Function):- RF Power Meters- RF Power Sensors- Spectrum Analyzers- RF Level Meters- Modulation Analyzer- Radio Communication Analyzers- Site Masters- Network AnalyzersRange: -100dBm~44dBm, 100Hz~40GHz, 50Ω, 75Ω, 600Ω
Example of Instrument (RF Source Function):- Signal Generators / Function Generators- Synthesized Sweepers- Pulse Generators- RF Oscillators- Synthesized Level Generators- Network Analyzers- RF Power Amplifier / Splitter
Range: -100dBm~44dBm, 100Hz~40GHz, 50Ω, 75Ω, 600Ω
Standard Equipment: Functions/Ranges:
- Rubidium Frequency Standard, Sansei FSR-101- Universal Counter, HP 53132A (Opt-012-030)- Universal Counter, Advantest TR5822- Microwave Frequency Counter, HP 5352B- Synthesized Function Generator, HP 3325B- Synthesizer-Level Generator, Anritsu MG443B- Signal Generator, HP ESG-4000A- ESGD Series Signal Generator, HP E4433B- Synthesized Sweeper, HP 8340B- Synthesized Sweeper, HP 83620A- Synthesized Sweeper, HP 83640A
- Freq.: 1MHz, 5MHz, 10MHz- Freq.: 1Hz ~ 3GHz- Freq.: 1Hz ~ 3GHz- Freq.: 100MHz ~ 40GHz- Freq.: 1Hz ~ 21MHz- Freq.: 10H ~ 30MHz- Freq.: 100kHz ~ 4GHz- Freq.: 250kHz ~ 4GHz- Freq.: 10MHz ~ 26.5GHz- Freq.: 10MHz ~ 20GHz- Freq.: 10MHz ~ 40GHz
Standard Equipment: Functions/Ranges:- RF Power Meter, HP436A, E4419B, EPM442A- RF Power Meter, Anritsu ML4803A- Power Sensor, HP 8482A, HP 8482B- Power Sensor, HP E4412A, HP E9301A- Power Sensor, Anritsu MA4601A, Anritsu MA4602A- Range Calibrator, HP 11683A, HP 8477A- Range Calibrator, Anritsu MA4001A- Measuring Receiver, HP 8902A/11722A- Spectrum Analyzer, HP8593E ,HP8564E, HPE4406A- Spectrum Analyzer, Advantest R3465- Selective Level Meter, Anritsu ML422C- Signal Generator, HP 3325B, HP ESG-4000A, HP E4433B, HP 8340B- Signal Generator, HP 83620A, HP 83640A- Syntesized Level Generator, Anritsu MG443B, - RF Power Amplifier, 25WI000M7- RF Power Splitter, HP 11667A, HP 11667B
- RF Power: 50Ω, 0.1nW - 25W (100kHz - 40GHz)- RF Power: 75Ω, 0.1nW - 100mW (100kHz - 2GHz)- RF Power: 50Ω, 0.1µW - 100mW (10MHz - 18GHz)- RF Power: 50Ω, 0.1µW - 100mW (10MHz - 6GHz)- RF Power: 75Ω, 0.1nW - 100mW (100kHz - 2GHz)- RF Power: 50Ω, 0.1nW - 25W (100kHz - 40GHz)- RF Power: 75Ω, 0.1nW - 100mW (100kHz - 2GHz)- RF Power: 50Ω, -127dBm~30dBm (100kHz - 1.3GHz)- RF Power: 50Ω, -120dBm~30dBm (30Hz - 40GHz)- RF Power: 75Ω, -120dBm~30dBm (30Hz - 40GHz)- RF Power: 50~600Ω, -120dBm~30dBm (50Hz - 30MHz)- RF Power: 50Ω, -120dBm~30dBm (100kHz - 40GHz)- RF Power: 50Ω, -120dBm~30dBm (100kHz - 40GHz)- RF Power: 50~600Ω, -120dBm~30dBm (50Hz - 30MHz)- RF Power: 50Ω, Max. 25W (25MHz - 1GHz)- RF Power: 50Ω, -120dBm~30dBm (100kHz - 40GHz)
Standard Equipment Ranges: - Rubidium Frequency Standard, R&S XSRM - Frequency Converter, R&S XSRM# - GPS Time and Frequency Standard Receiver, HP 58503A
- Freq.: 5 MHz- Freq.: 0.1~10MHz- Freq.: 10 MHz
Standard Equipment RF Power Ranges: - Power Sensor, HP 8484A - Power Sensor, HP 8481A - Power Sensor, HP 8482A
- 50Ω: 0.1nW~10µW (10MHz~18GHz)- 50Ω, 1µW~100mW (10MHz~18GHz)- 50Ω, 1µW~100mW (100kHz~4.2GHz)
Standard Equipment RF Power Ranges: - Power Sensor, HP E4413A - Power Sensor, HP 8487A - Power Sensor, HP 8483A
- 50Ω, 0.1nW~100mW(100MHz~26.5GHz)- 50Ω, 1µW~100mW (50MHz~50GHz)- 75Ω, 1µW~100mW (100kHz~2GHz)
National Institute of Metrology (Thailand), NIMT
Agilent Technologies (Japan)(JCSS no.: 0048)
NEC Purchasing Ltd. (Japan)
National Metrology Institute of Japan (NMIJ), Japan
CalibrationNo. 0132
![Page 5: 07 NEC ELEC Traceability Chart 1 20-Mar-09 · 75/107 M. 11, Paholyothin Rd., Klong 1, Klong Luang, Pathumthani 12120 Tel. (66) 2-529-2460, Fax. (66) 2-529-2466 Traceability Chart](https://reader036.fdocuments.net/reader036/viewer/2022071112/5fe7f408f559c713a92ab478/html5/thumbnails/5.jpg)
National Standard
AccreditedLaboratories
NEC's HighestStandards
NEC's WorkingStandards
Customer'sEquipment
Remark: * ISO/IEC 17025 accredited scopes by Thai Laboratory Accreditation Scheme (Thai Industrial Standards Institute, Ministry of Industry).* Accredited scopes only ACV, DCV and frequency only
FEZ-0009-G-Form-03/V5 /01/04/08
22-Nov-07 Calibration CenterNEC Corporation (Thailand) Ltd.75/107 M. 11, Paholyothin Rd.,Klong 1, Klong Luang, Pathumthani 12120Tel. (66) 2-529-2460, Fax. (66) 2-529-2466
Traceability ChartPrepared by:
(TM)Date: 24-Mar-09
Approved by:
(TM Leader)Date: 24-Mar-09
Scope: Electrical Calibration (5) (RF Att./SWR/TV/Tel/Flutter/Jitter/LF)
RF Attenuation/Impedance From RF Power Sources/Meters: Noise Meters/Sources:
- Noise Figure Analyzers - Noise Sources/Generators
- RF Attenuators- RF Attenuators- RF Attenuators- RF Attenuators- RF Termination/Calibration Kit- RF Termination/Calibration Kit- RF Impedance from Signal Sources- RF Impedance from Signal Meters- RF Attenuation from Signal Sources
- RF Attenuation from Signal Meters
Standard Equipment: Ranges:
- Fixed Att. Set, HP 8492A Series- Fixed Att. Set, Tektronix 011-0059- Fixed Att. Set, Weinschel Model 2 Series- VHF Attennuator, HP 355C/355D- Decade Attenuator, Ando AL352
- Network Analyzer, HP 8753D- Network Analyzer, Wiltron 360- Calibration Kit, HP85031B,85032B,85036B- Calibration Kit, Wiltron 3652
- 50Ω BNC, N, APC 3.5mm (0~120dB, DC~40GHz)
- 600/75Ω Balance (0~91dB, DC~700kHz)
- 50Ω BNC, N, APC 3.5mm (0~120dB, DC~40GHz)
Standard Equipment:
Standard Equipment Ranges: - Fixed Attennuator Set, Weinschel 44's - Fixed Attennuator Set, Agilent 8493C - Fixed Attennuator Set, Wiltron 41KC-S - Decade Attennuator, Anritsu MN61B - Termination, Wiltron 26N50, 26NF50 - Termination, Wiltron 28A50 - Termination, Maury 351A, 351B - Termination, Wiltron 28K50, 28KF50 - Termination, Wiltron 26N75, 26NF75 - Termination, HP 902C, 902D
- 50Ω: 10~40dB (DC~18GHz)- 50Ω: 30~40dB (DC~26.5GHz)- 50Ω: 3~20dB (DC~40GHz)- 75Ω: 0~91dB (DC~1.5GHz)- 50Ω: Type N (DC~18GHz)- 50Ω: Type APC 7mm (DC~18GHz)- 50Ω: Type BNC (DC~10GHz)- 50Ω: Type K (DC~40GHz)- 75Ω: Type N (DC~8GHz)- 50Ω: Type 3.5mm (DC~26.5GHz)
Standard Equipment:
- Noise Generator Agilent N4001A
- Multimeter, HP3458A, 34411A, 34401A- Multi Product Calibrator, 5520A, 5500A- Oscilloscope,Tektronix TDS684B,TDS540A- Measuring Receiver HP8902A- Modulation Analyzer 8901B- Audio Analyzer, VP7725A, HP 8903B- Telephone Unit Tester, Ando AE9303- Impulse Sender, Ando AE-3106- Wow Flutter/CD/DVD Jitter Calibrator,Minato 3101, Act 3901- Rubidium Frequency Standard, Sansei FSR-101- Universal Counter, HP53132A.012.030, Advantest TR5822
Standard Equipment: Ranges:
National Metrology Institute of Japan (NMIJ), Japan National Institute of Metrology (Thailand), NIMT
CalibrationNo. 0132
TV Signal Analyzers/Sources Instruments: - * PAL Pattern Generators - * NTSC Pattern Generators - * PAL Vector Scopes - * NTSC Vector Scopes - * Video Generators - * Video Analyzers - * Video Noise Meters - * Video Pattern Generators - * Video Sweep Generators
Other LF/Audio/Modulation Instruments: - * Audio Analyzers/Generators - * CD Jitter Meters/Calibrators - * CD/MD Tracking Offset/Phase Meters/Generators - * DVD Jitter Meters/Calibrators - * VTR Jitter Meters/Generators - * WOW Flutter Meters/Generators - * Telephone Unit Analyzers/Generators - * Bell Ringer Analyzers/Generators - * Digital/Analog Radio Testers/generators - * AM/FM/Phase Modulation Analyzers/Generators - * Distortion Analyzers/Generators - * Oscilloscopes/Oscilloscopes Calibrators
- 50Ω: 0~100dB, DC~40GHz- 75Ω: 0~90dB, DC~1.5GHz- 75Ω Balance: 0~91dB, DC~700kHz- 600Ω Balance: 0~91dB, DC~150kHz- 50Ω: DC~40GHz- 75Ω: DC~1.5GHz- 50Ω: DC~40GHz, 75Ω: DC~1.5GHz- 50Ω: DC~40GHz, 75Ω: DC~1.5GHz- 50Ω: 0~100dB, DC~40GHz, 75Ω: 0~90dB, DC~1.5GHz- 50Ω: 0~100dB, DC~40GHz, 75Ω: 0~90dB, DC~1.5GHz
NEC Purchasing Ltd. (Japan)
Standard Equipment:
- Noise Figure Meter, Agilent N8972A - PowerAmplifier, Agilent 8447D
Standard Equipment:
- Signal Generator, Tektronix TG2000 - Mixed Signal Audio Measurment Set, Tektronix AM700 - NTSC TV Generator, Tektronix 1410 - PAL TV Generator, Tektronix 1411 - Video Measurement System,Tektronix VM700T
Level:- Digital Multimeter, Agilent 3458A- AC Measureing Standard, Fluke 5790A+Wide Band- Multi-Function Calibrator, Fluke 5720A- Multi-Function Calibrator, Fluke 57020A+Wide Band
Frequency:- Rubidium Frequency Standard, R&S XSRM
Level:- DCV/ACV: Up~700V (10Hz~10MHz)- ACV: Up~1kV (10Hz~30MHz)- DCV/ACV: Up~1kV (10Hz~1MHz)- DCV/ACV: Up~1kV (10Hz~30MHz)
Frequency:- Freq.: 0.1MHz, 1MHz, 5MHz, 10MHz
![Page 6: 07 NEC ELEC Traceability Chart 1 20-Mar-09 · 75/107 M. 11, Paholyothin Rd., Klong 1, Klong Luang, Pathumthani 12120 Tel. (66) 2-529-2460, Fax. (66) 2-529-2466 Traceability Chart](https://reader036.fdocuments.net/reader036/viewer/2022071112/5fe7f408f559c713a92ab478/html5/thumbnails/6.jpg)
National Standard
AccreditedLaboratories
NEC's HighestStandards
Wavelength Attenuation Power
NEC's WorkingStandards
Customer'sEquipment
FEZ-0009-G-Form-03/V5 /01/04/08
Calibration CenterNEC Corporation (Thailand) Ltd.75/107 M. 11, Paholyothin Rd.,Klong 1, Klong Luang, Pathumthani 12120Tel. (66) 2-529-2460, Fax. (66) 2-529-2466
Traceability Chart22-Nov-07
Prepared by:
(TM)
Date: 24-Mar-09
Approved by:
(TM Leader)
Date: 24-Mar-09
Scope: Electrical Calibration (6) (Optical)
Optical Wavelength / Optical Components / Optical Powers: - Laser Sources / Lightwave Meters - Lightwave Switchs - Lightwave Transmitters / Receivers - Optical Spectrum Analyzers - Optical Time Domain Reflectmeters - Plug in Modules - Polarization
- Optical Attenuators - Optical Direction Couplers - Optical Grating Filters - N2X Card - NIC - Pulse Pattern Gen - Return Loss
- Communication Test Sets - Error Detectors - Infiniium DCA - Laser Diode Drivers - OmniBER Communication Analyzers - Optical Power Meters / Power Sensors - OTDR
- Single Mode Clock Recovery - SONET Transmittion Test Set - SpectralBER DWDM Module - SPLTR - SunSet - SunLite - T-Bird T-Carrier Analyzers
- Data Communication/Digital Communication Analyzer - 20GHz Optical/Electrical Converter - SONET/SDH Analyzer
- Agilent 83480A/83485A (2.488Gb/s), 83480A/83485B (9.953Gb/s) - Agilent 83440C (DC~20GHz) - Anritsu MP1570A (10G)
- Optical Component/Optical Time Domain Reflectmeter - Polarization Controller - Return Loss Module - Optical Directinal Coupler
- Agilent 8147 - Agilent 8169 - Agilent 81534A - Anritsu MN9604B
- Laser Source, Agilent 81640A/81650A/81689A- LD Source, Anritsu MG0938C / Ando AQ4212 / Anritsu MG9002A
(1310, 1510~1640 nm)
Optical Spectrum Analyzer,Anritsu MS9710B
(1300~1550 nm, -10~-50dB)
Optical Attenuator,Agilent 8156A / Anritsu MN9605C
(1300~1550 nm, 1~60dB)
Optical Power Sensors,Agilent 81521B/81525A/81532A(1300~1550 nm, +27~-110dB)
Optical Power Sensors,Agilent 81624A
(1300~1550 nm, +10~-90dB)
Optical Attenuator,Agilent 8156A
(1300~1550 nm, 1~60dB)- Lightwave Multi-Meter, Agilent 8153A
- Multi-Wavelength Meter, Agilent 86120C- Lightwave Measurement System, Agilent 8164A
- Lightwave Multimeter, Agilent 8163A- Optical Multimeter, Ando AQ2140
(1300~1550 nm +/- 0.003 nm, 1~60dB)
Primary Wavelength MeterWA-1150/WFM-601M
Primary Optical AttenuatorAgilent 8158B/8156A
Japan Quality Assurance Organization (JQA) / Agilent Technologies (Japan) / EXFO Asia Pacific PTE Ltd. (Japan)
National Metrology Institute of Japan (NMIJ), Japan National Institute of Metrology (Thailand), NIMT
CalibrationNo. 0132
![Page 7: 07 NEC ELEC Traceability Chart 1 20-Mar-09 · 75/107 M. 11, Paholyothin Rd., Klong 1, Klong Luang, Pathumthani 12120 Tel. (66) 2-529-2460, Fax. (66) 2-529-2466 Traceability Chart](https://reader036.fdocuments.net/reader036/viewer/2022071112/5fe7f408f559c713a92ab478/html5/thumbnails/7.jpg)
National Standard
NEC's HighestStandards
NEC's WorkingStandards
Customer'sEquipment
Remark: * ISO/IEC 17025 accredited scopes by Thai Laboratory Accreditation Scheme (Thai Industrial Standards Institute, Ministry of Industry).FEZ-0009-G-Form-03/V5 /01/04/08
Calibration CenterNEC Corporation (Thailand) Ltd.75/107 M. 11, Paholyothin Rd.,Klong 1, Klong Luang, Pathumthani 12120Tel. (66) 2-529-2460, Fax. (66) 2-529-2466
Prepared by:
(TM)Date: 02-Mar-09
Approved by:
(TM Leader)Date: 02-Mar-09
Traceability Chart
Scope: Dimensional Calibration (1)
CalibrationNo. 0132
- Gauge Blocks *- Long Gauge Block
(Steel, Ceramic, Carbide)Grade 0, 1, 2
Range: 0.1~300mm
- Calibration Testers *- Dial Gauge Testers *
- Coating Thickness Plates
- Linear Probes
Range: 0~500mm
- Caliper Checkers*- Depth Micro-Checkers*
- Height Masters- Riser Blocks
- Check Masters- Master Bars- Setting Bars
Range: 0~600mm
- Outside Micrometers (0~1000mm)*- Inside Micrometers (0~300mm)*- Depth Micrometers (0~300mm)*- Thickness Gauges (0~100mm)*- Height Gauges (0~1000mm)*
- Calipers (0~ 1500mm)*- Depth Gauges (0~600mm)- Caliper Gauges (0~300mm)
- Micrometer Heads (0~100mm)- Electrical Comparators (0~10mm)*
- Precision Levels (0~5mm/m)*
- Electric Levels (0~5mm/m)*
Others- Snap Gauges
- Straightness Edge- Horizontal Machines
- Length Measuring Machines- Coating Thickness Gauges
- Gauge Block Set (GradeK, 0)
- Electronic Comparator- Laser Hologauge
(Uncertainty: 0.02~0.20µm)
- Laser Hologauge
(Uncertainty: 0.1~0.2µm)
- Gauge Block Set(Grade K, 0, 1)
- Electronic Comparator- Precision Surface Plate
(Grade 0)
(Uncertainty: 0.02~0.20µm)
- Gauge Block Set (Grade 0, 1, 2)- Long Gauge Block Set (Grade 0, 1)
- Caliper Checkers- Depth Micro-Checkers
- Precision Surface Plates (Grade 0)
(Uncertainty: 0.07~3.0µm)
- Small Angle Generator- Laser Hologauge
- Digimatic Indicator- Gauge Block Set (Grade 0, 1, 2)
(Uncertainty: 0.07~2.0µm)
- Gauge Block Set(Grade 0, 1, 2)
- Long Gauge Block Set(Grade 0, 1)
- Precision Surface Plates(Grade 0)
(Uncertainty: 0.07~0.20µm)
- Long Gauge Block Set (Grade K, Range 100~500mm)(Uncertainty: 0.04~0.20µm)
- Gauge Block Set (Grade K, Range 0.1~100mm)(Uncertainty: 0.02~0.04µm)
National Institute of Metrology (Thailand), NIMTNational Measurement Institute (NMIA), Australia
National Metrology Institute of Japan (NMIJ)
![Page 8: 07 NEC ELEC Traceability Chart 1 20-Mar-09 · 75/107 M. 11, Paholyothin Rd., Klong 1, Klong Luang, Pathumthani 12120 Tel. (66) 2-529-2460, Fax. (66) 2-529-2466 Traceability Chart](https://reader036.fdocuments.net/reader036/viewer/2022071112/5fe7f408f559c713a92ab478/html5/thumbnails/8.jpg)
National Standard
NEC's HighestStandards
NEC's WorkingStandards
Customer'sEquipment
Remark: * ISO/IEC 17025 accredited scopes by Thai Laboratory Accreditation Scheme (Thai Industrial Standards Institute, Ministry of Industry).FEZ-0009-G-Form-03/V5 /01/04/08
Digital Indicator
Calibration CenterNEC Corporation (Thailand) Ltd.75/107 M. 11, Paholyothin Rd.,Klong 1, Klong Luang, Pathumthani 12120Tel. (66) 2-529-2460, Fax. (66) 2-529-2466
Prepared by:
(TM)
Date: 02-Mar-09
Approved by:
(TM Leader)
Date: 02-Mar-09
Traceability Chart
Scope: Dimensional Calibration (2)
CalibrationNo. 0132
- Feeler Gauges*
Range:0.1~10mm
- Dial Gauges*- Dial Test Indicators*
- Bore Gauges- Cylinder Gauges
Range:0~100mm
- Pin Gauges*- Plug Gauges*- Laser Scan Micrometers
- Three Wires*
Range:0.1~100mm
- Profile Projectors
- Measuring Microsocopes- Scale Loops
Range: 0~300mm
- Holtest*
Range: 2~100mm
- Surface Plates
Size: 300*300mm
up
- Glass Scales
Range: 0~300mm
- Protactors- Angle Gauges- Radius Gauges- Taper Gauges- Metal Rules
Range: 0~300mm
Digimatic Indicator
Uncertainty: 1.0µm
CalibrationTesters
Uncertainty: 0.4µm
- Standard Pin Gauge Set- Laser Scan Micrometer
Uncertainty: 0.2~0.5µm
- Thread Plug Gauges
- Thread Ring Gauges
Range:1~100mm
- 3-W Set- Thread Plug
Gauge SetUncertainty: 1.0µm
- Working Glass Scale
- Microscope Calibrator
Uncertainty: 1.0µm
- Standard GlassScale
Uncertainty: 0.3µm
- Profile Projector- Angle Gauge
Uncertainty: 1.0µm
- CMM
Range: 0~1000mm
- Steel Tape- Metal Rule
Text Tile Tape
Range: >300mm
Ring Gauge Set
Uncertainty: 0.5µm
3-D Master
Uncertainty: 0.5µm
Standard Tape
Uncertainty: 0.5µm
Electronic Level Meter
Uncertainty: 0.5µm
National Institute of Metrology (Thailand), NIMTSwiss Federal Office of
Metrology (OFMET), Switzerland
Laser Hologauge(Uncertainty: 0.1~0.2µm)
Gauge Block Set (Grade K)(Uncertainty: 0.02~0.04µm)
![Page 9: 07 NEC ELEC Traceability Chart 1 20-Mar-09 · 75/107 M. 11, Paholyothin Rd., Klong 1, Klong Luang, Pathumthani 12120 Tel. (66) 2-529-2460, Fax. (66) 2-529-2466 Traceability Chart](https://reader036.fdocuments.net/reader036/viewer/2022071112/5fe7f408f559c713a92ab478/html5/thumbnails/9.jpg)
National Standard
NEC's HighestStandards
NEC's WorkingStandards
Customer'sEquipment
Remark: * ISO/IEC 17025 accredited scopes by Thai Laboratory Accreditation Scheme (Thai Industrial Standards Institute, Ministry of Industry).FEZ-0009-G-Form-03/V5 /01/04/08
Calibration CenterNEC Corporation (Thailand) Ltd.75/107 M. 11, Paholyothin Rd.,Klong 1, Klong Luang, Pathumthani 12120Tel. (66) 2-529-2460, Fax. (66) 2-529-2466
Prepared by:
(TM)Date: 19-Mar-09
Approved by:
(TM Leader)Date: 19-Mar-09
Traceability Chart
Scope: Force & Torque Calibration
CalibrationNo. 0132
Force Measuring Instrument- Push-Pull Scales *- Tension Gauges *
- Dial Tension Gauges *- Force / Digital Force Gauge *
Range: 0~500kgf
Torque Instrument- Digital / Mechanical Torque Testers
- Torque Gauges- Torque Wrenches
- Torque Drivers- Torque Screw Drivers
Range: 0~2,000kgf.cm
Force Machines (On-site)- Tensile Testing Machines
- Autograph Machines
Range: 0~10kN
- Standard Weight Set, OIML Class E2, F1(Mettler-Toledo)
- Standard Weight Set, OIML Class F1 (Kern)- Standard Weight Set, OIML Class F2 (Moriya)- Standard Weight Set, OIML Class M1 (Moriya)
- Hook / Slot Weight Set (RRK)
Range: 1mg~500kg
- Digital Torque Tester (HIOS)- Digital Torque Tester (KANON)- Digital Torque Tester (Tohnichi)
Range: 0~2,000kg.cm
- Hook / Slot Weight Set (SSK)Range: 0~200kg
- Beam Standard (Hios, Kanon)Range: 1cm~20cm
- Digital Force Indicator (HBM)- Load Cell Standard (HBM)
Range: 0~10kN
- Standard Weight Set, OIML Class E2 (Mettler-Toledo)
Range : 1mg~20kg
- Gauge Block Set Grade KRange : 0.5mm~500mm
National Institute of Metrology (Thailand), NIMT
![Page 10: 07 NEC ELEC Traceability Chart 1 20-Mar-09 · 75/107 M. 11, Paholyothin Rd., Klong 1, Klong Luang, Pathumthani 12120 Tel. (66) 2-529-2460, Fax. (66) 2-529-2466 Traceability Chart](https://reader036.fdocuments.net/reader036/viewer/2022071112/5fe7f408f559c713a92ab478/html5/thumbnails/10.jpg)
National Standard
NEC's HighestStandards
NEC's WorkingStandards
Customer'sEquipment
Remark: * ISO/IEC 17025 accredited scopes by Thai Laboratory Accreditation Scheme (Thai Industrial Standards Institute, Ministry of Industry).FEZ-0009-G-Form-03/V5 /01/04/08
Calibration CenterNEC Corporation (Thailand) Ltd.75/107 M. 11, Paholyothin Rd.,Klong 1, Klong Luang, Pathumthani 12120Tel. (66) 2-529-2460, Fax. (66) 2-529-2466
Traceability Chart
CalibrationNo. 0132
Prepared by:
(TM)Date: 16-Mar-09
Approved by:
(TM Leader)Date: 16-Mar-09
Scope: Mass Calibration
- Steel Weights *- Brass Weights *
- Stainless Steel Weights *- Other Material Made Weights *
OIML Class F1, F2
Range: 1mg~20kg
- Steel Weights *- Brass Weights *
- Stainless Steel Weights *- Other Material Made Weights *
OIML Class F2, M1, M2, M3, No-Class
Range: 1mg~20kg
- Electronic Balances *- Spring Balances *- Other Balances *
Range: 0g~500kg
- Standard Weight Set, OIML Class E2(Mettler-Toledo)
- Mass Comparator, Mettler-Toledo, AT201- Mass Comparator, Mettler-Toledo, PR2004
- Mass Comparator, Mettler-Toledo, KA30-3/P
Range: 1mg~20kg
- Standard Weight Set, OIML Class F1(Mettler-Toledo)
- Standard Weight Set, OIML Class F1(Kern)
- Mass Comparator, Mettler-Toledo, AT201- Mass Comparator, Mettler-Toledo, PR2004
- Mass Comparator, Mettler-Toledo, KA30-3/P
Range: 1mg~20kg
- Standard Weight Set, OIML Class E2, F1(Mettler-Toledo)
- Standard Weight Set, OIML Class F1(Kern)
- Standard Weight Set, OIML Class F2(Moriya)
Standard Weight Set, OIML Class M1(Moriya)
Range: 1mg~500kg
National Institute of Metrology (Thailand), NIMT
- Standard Weight Set, OIML Class E2 (Mettler-Toledo)Range : 1mg~20kg
Physikalisch Technische Bundesanstalt (PTB), Germany
Swiss Federal Office of Metrology (OFMET)
![Page 11: 07 NEC ELEC Traceability Chart 1 20-Mar-09 · 75/107 M. 11, Paholyothin Rd., Klong 1, Klong Luang, Pathumthani 12120 Tel. (66) 2-529-2460, Fax. (66) 2-529-2466 Traceability Chart](https://reader036.fdocuments.net/reader036/viewer/2022071112/5fe7f408f559c713a92ab478/html5/thumbnails/11.jpg)
National Standard
NEC's HighestStandards
NEC's WorkingStandards
Customer'sEquipment
Remark:FEZ-0009-G-Form-03/V5 /01/04/08
Calibration CenterNEC Corporation (Thailand) Ltd.75/107 M. 11, Paholyothin Rd.,Klong 1, Klong Luang, Pathumthani 12120Tel. (66) 2-529-2460, Fax. (66) 2-529-2466
Prepared by:
(TM)Date: 19-Mar-09
Approved by:
(TM Leader)Date: 19-Mar-09
Traceability Chart
Scope: Other Scopes of Calibration
CalibrationNo. 0132
- Rubber Hardness Testers
- Duro Meters
(JIS / ASTM Type)(0~100o)
- Pressure Gauges- Pressure Transducer
- Pressure Switch- Pressure Indicator
(0~50kgf.cm2) or quivalent unit
Roundness Testers Roughess Testers
(Ra, Ry)
Hardness Testing Machines
(Vicker / Rockwell)
(HMV, HRC, HRB)
- Viscosity Testers- Viscosity Meters
(125~147,877 mPa.s)
pH Meter(With Probes)
(pH 4~10)
Conductivity(With Probes)
(0.1nS~1S)
Duro Meter Tester (Teclock)
Range: 0~100o
- Hydraulic Dead Weight Tester
(Nagano)- Pressure
Calibrator (Fluke)- Pressure Module
(Fluke)
Range: 0~50kgf.cm2
Master Ball(Tokyo Semitsu)
E-MG-R054)
Roughness Standard(Tokyo Semitsu)
Standard Block for Hardness(NIMT)
Standard Liquid for Calibrating Viscometers
(Nippon Grease)
(JS 500 / 1,000 /2,000 / 14,000 /
160,000)
pH Solution Standard
(Mettler-Toledo)
(pH 4~10)
- Conductivity Solution Standard(Mettler-Toledo)
- Decade Resistance Boxes
(0.1nS~1S)
Standard Weight Set, OIML Class E2
(Mettler-Toledo)
National Institute of Metrology (Thailand), NIMT
Digital Multimeter (Agilent 3458A)
National Institute of Standard and
Technology, U.S.A.
National Metrology Institute of Japan
(NMIJ), Japan
![Page 12: 07 NEC ELEC Traceability Chart 1 20-Mar-09 · 75/107 M. 11, Paholyothin Rd., Klong 1, Klong Luang, Pathumthani 12120 Tel. (66) 2-529-2460, Fax. (66) 2-529-2466 Traceability Chart](https://reader036.fdocuments.net/reader036/viewer/2022071112/5fe7f408f559c713a92ab478/html5/thumbnails/12.jpg)
National Standard
NEC's HighestStandards
NEC's WorkingStandards
Customer'sEquipment
Remark: * ISO/IEC 17025 accredited scopes by Thai Laboratory Accreditation Scheme (Thai Industrial Standards Institute, Ministry of Industry).
FEZ-0009-G-Form-03/V5 /01/04/08
Calibration CenterNEC Corporation (Thailand) Ltd.75/107 M. 11, Paholyothin Rd.,Klong 1, Klong Luang, Pathumthani 12120Tel. (66) 2-529-2460, Fax. (66) 2-529-2466
Prepared by:
(TM)Date: 20-Mar-09
Approved by:
(TM Leader)Date: 20-Mar-09
Traceability Chart
Scope: Temperature Calibration
CalibrationNo. 0132
Temperature Sensors: - Thermocouple Sensors * - Thermocouple Extension Wire* (Type E / J / K / N / R / S / T) - RTD Sensors *
Range: -20oC~700oC
Thermometers: - Liquid-in-glass Thermometers * - Thermometer With Sensors * (Analog / Digital) - Recorder With Sensors * - Surface Thermometers Range: -20oC~700oC
Temperature Sources: - Dry Block Calibrators * - Liquid Bath * - Chambers, Oven * - Incubators, Autoclave *
Range: -40oC~1,000oC
Thermo-Hygro: - Thermo-Hygrographes - Thermo-Hygrometers (Analog / Digital) - Humidity Transmitter
Range: Tem. -20oC~50oC Hum. 20%~90%rh
Temperature Indicators / Simulators: - Hybrid Recorders * - Reflow / Soldering Testers * - Data Logger / Thermometer * - Process Calibrators * - Temperature Calibrators *
Range: TC all type, RTD all type
Standard Sensors and Thermometers: Temperature Sources: - PRT Standard Sensor (Asahi), Pt-100 - PRT Standard Sensor (Anritsu), Pt-100 - PRT Standard Sensor (Netsushin), Pt-100 - Type S Thermocouple (High Temp.) - Type T Thermocouple Set (RS) - High Precision LIG Thermometers (Nippon Kei) - Black Stack Thermometer (Hart 1560, 2562) - Reference Junction Set (Type E, J, K, N, R, S, T) - Data Logger With RTD Sensor (Agilent 34970A) - Hybrid Recorder With Type T Sensors (Yokogawa) - Digital Thermometer (Yokogawa 7563-21) - Humidity Transmitters (Rense)
- Dry Block Calibrator (Hart Scientific, 9105)- Dry Block Calibrator (Hart Scientific, 9122A)- Surface Calibrator (Anritsu ACSII)- Liquid Bath (Jubalo)- Micro Bath (Hart Scientific, 6102 7103)- Temperature / Humidity Controlled Chamber (Espec, PR1KP)
Standard Simulators: - Multi-Product calibrators (Fluke 5520A) - Process Calibrator (Fluke 744)
Standard Indicators: - Digital Multimeter (Agilent 3458A) - Digital Multimeter (Fluke 8846A)
- SPRT Standard (Hart Scientific, 5626)- Type S Standard Thermocouple (High Temp.)
- High Precision Thermo-Hygrometer (Fluke 1621A)
- Multi-Function Calibrator(Fluke 5720A)
- DCV Standard (Fluke 732B)
National Institute of Metrology (Thailand), NIMT