05-0238 RIG SAVER TECHNICAL BULLETIN PORTAL
Transcript of 05-0238 RIG SAVER TECHNICAL BULLETIN PORTAL
11 SGE Pneumatically Actuated with Manual Pull Knob
Description —Airborne hydrocarbons present a threat to controlled diesel engine operation. These hydrocarbons may be drawn into the air intake system causing the engine to acceler-ate out of control with the attendant risk of explosion and fi re. Conventional shut-down methods (i.e. shutting off the engine’s fuel supply) may be ineffective in preventing engine runaway.
The WGPC RIG SAVER, a spring oper-ated air shut-off device mounted in the air intake system, will block the air fl ow and positively stop the engine. The RIG SAVER can be manually or automatically controlled, responding to a variety of fault or hazard conditions.
Edmonton, Alberta, Canada Tel +1 (780) 450-3401 Fax +1 (780) 450-3413 E-mail [email protected] www.woodgroup.biz/rigsaver
Wood Group Pressure Control
Technical Bulletin: #05-0238
RIG SAVER
5 SGE Electric Solenoid Actuatorwith Marman Clamp Mounts
4 SGE Hose Mounted with Clevis Pull
The RIG SAVER has been used worldwide, providing reliable ser-vice on and offshore under the adverse conditions associated with locations in the Canadian Arctic, the Gulf of Mexico, the North Sea, the deserts of Africa, the Middle East and the Pacifi c Rim.
Features —• Manual or automatic controls• Can be used on-shore and off-shore• Can respond to a variety of fault or hazard conditions• Available with 2” (50mm) to 14” (355mm) of unrestricted port• Operates safely at ambient and induction air temperatures
between 350°F – 400°F (176°C – 205°C) • Meets ISO 9001 requirements
Applications —• Power generations• Off-shore platforms• Bulk fuel loading facilities• Marine engine rooms• Mining equipment• Refi neries• Petrochemical plants
TM
295-3092
295-3093
295-3094
RIG SAVER is often used in marine applications
RIG SAVER shown in service on a large diesel engine
RIG SAVER
Wood Group Pressure Control
Models
Dimensions in Inches
Weight (lbs.)A B C D *E F G H J K
L(max. bore)
2 SGE 1.50 5.51 3.78 4.96 6.30 1.40 1.70 2.11 2.25 2.45 2.00 2.1
3 SGE 2.06 7.44 5.44 6.40 10.58 1.75 2.16 3.19 2.94 3.25 3.00 6.0
4 SGE 2.63 9.10 7.13 7.31 10.70 1.88 2.22 4.14 3.70 3.73 4.00 8.5
5 SGE 3.25 11.12 9.00 9.18 12.32 2.00 2.50 5.19 4.50 4.19 5.00 10.0
6.5 SGE 4.25 12.69 12.00 12.00 16.70 2.50 3.14 5.56 5.76 4.81 6.50 25.0
8 SGE 5.00 14.73 14.25 13.60 17.62 2.50 3.25 6.75 6.73 5.25 8.00 35.0
11 SGE 6.68 20.00 18.56 17.65 21.00 3.00 4.75 9.12 9.13 7.43 11.00 70.0
14 SGE 9.00 26.10 25.00 28.00 N/A 7.38 10.65 14.16 11.90 9.00 14.00 276.0
A Radius
J
K C
B
H
D
*E F
Bore L
G
* This measurement does not cover all possible operational methods. For specifi c operational methods and their respective dimensions, please contact WGPC Canada Engineering.
295-3108