047 - Site Plan 08
Transcript of 047 - Site Plan 08
9
10
2
FFORDD HENGOED
3000
MAES GWERN
VIE
W
VIE
W
ESTIMA
TED PO
SITION
OF FA
ULT LIN
E
ESTIMATED POSITION OF FAULT LINE
ESTIMATED POSITION OF FAULT LINE
POS226m2
3m WIDE SHARED USE FOOTPATH ABUTTINGPUBLIC OPEN SPACE AND EXISTING WATERCOURSETO SOUTHERN BOUNDARY
6
7
9
8
134
133
132
131
125
123
124
122
11
12
15
96
120
121
126
127
129
128
130
1
2
5
159
160
152
157
158
135
136137138139
146147
148149
151
155
156
154153
150
17
10
30000
30000
140 - 145
4
3
16
13
14
95
94
73
74
75
76
77
78
79
80
81
82
8485
8687
88
89
90
91
9293
97 - 102
103
104
105
106
107
108 - 113
114 - 119
83
6667
68
69
70
71
72
65
64
63
62
61
60
59
58
57
56
55
54
18
19
20
21
22
23
24
25
26
27
28
29
30
31
34
35
36
37
38
39
40
41
42
32
33
43
44
45
46
47
48
49
50
51
52
53
* *
*
**
**
* *
**
**
**
**
*
*
* *
D58
D57
D56
DF4
SEP4A
DF7
DF5A
DF5
DF3
DF2
DF1
TRA
DIT
ION
AL
ESTA
TE R
OA
D
VIE
W
PUBLIC OPEN SPACE
Tradition
al Estate Road
PRO
PERTY FR
ON
TAG
E
EXISTING GRAVEL FOOTPATH
MEWS COURT
Private Drive
Private Drive
RAISED TABLEJUNCTION
ME
WS
CO
UR
T
134
133
132131
125
123
124
122
120
121
126
127
129
128
130
152
135
136137138139
146147
148149
151
155
156
154 153
150
140 - 145
APARTMENTCAR PARKING
BINS
SUBSTATION
EXISTING GRAVEL FOOTPATH
71
72
GA
SE
LEC
SVP
D58
D57
D56
DF7
DF6
DF5A
DF5
DF4
DF3
DF2
SEP4A
DF7
DF6
DF5A
DF5
DF4
DF3
DF2
DF1
RW
P
*
* *
*
Grassed area
450 x 450 50 concrete pavings
Black bit mac road
Surfaces key:
Play Area
Colour Texture Bitmac
Permeable Bitmac
Drawing based on survey information provided by thirdparty measured surveys. Any discrepancies to be reportedto the architect.
SURFACE TREATMENTS1:200
Dwg. No.
Scale
Rev.
Copyright Halliday Clark Limited C 2018The details shown on this drawing are confidential and the drawing is
the exclusive property of Halliday Clark Limited. No use, copy or
disclosure of the drawing may be made without our permission and it
is to be returned to Halliday Clark Limited when required.
Halliday Clark Limited take no responsibility for the use of this
drawing for any purpose other than for that which it was intended.
All dimensions are in millimeters unless stated otherwise.
All dimensions should be verified on site prior to commencement of
works.
Do not scale from this drawing.
All works must be in accordance with British Standards, EC
Standards, Health & Safety at work act & all other relevant
regulations & Bye Laws.
Any discrepancies should be brought to the attention of Halliday
Clark Limited.
Halliday Clark Limited 21 The GroveIlkley LS29 9LW
01943 604 123 [email protected] hallidayclark.co.uk
TEW
FOR
REVISION - DATE DRWN CHKD
FOR COMMENT
-
INITIAL ISSUE
RESIDENTIAL DEVELOPMENTTREBEIRDDMAES GWERNMOLD
WATES RESIDENTIAL
SURFACE TREATMENTS SHEET 08
1:200 @ A1
671.06 (90) 047 B
12.10.2018 SAE
SITE LAYOUT KEY PLAN: Scale 1:200
0 2000 5000 10000 15000mm
-A 26.11.2018 SAE
Patio's reduced to 2B and 3B properties and increased at thebigger house types as per Wates request.Sheds added to affordable units and resin bound gravel replacedby colour texture Bitmac.
-B 01.02.2019 SAEDrawing revised to reflect changes made to the bay windows.