03 - BreezeMAX - System Architecture CPE - 09-11-16 - Ver
description
Transcript of 03 - BreezeMAX - System Architecture CPE - 09-11-16 - Ver
-
CPE Architecture
Copyright Alvarion Ltd.
-
2Objectives
Upon completion of this module students will know the following: Subscriber components
Mechanical concept Led indications Specifications
-
3Subscriber Unit Indoor
-
4Subscriber Unit Indoor
The Subscriber Unit (SU) installed at the customer premises
Ports
1 * 10/100BaseT Ethernet
Ethernet 10/100 Mbps
BMAX-CPE-ODU-PRO-
SA-ffBMAX-CPE-IDU-1D
(indoor)hub /
switch
PC
PC
ALVR-VG-1DnV-C
ALVR-VG-1DnV-C
1 * Ethernet "Radio" port to ODU (+DC voltage)
Bridge functionality
Up to 512 MAC addresses behind the SU
The SU is powered from the mains
Indoor
BMAX-CPE-ODU-PRO-
SE-ff
802.11g
PCPC
PC PC
PC
BMAX-CPE-IDU-NG-4D1W(indoor)
For the detailed information of the next slides please refer to theBreezeMAX CPEsProduct Manual
-
5Subscriber Unit Indoor
Ethernet 10/100 Mbps
BMAX-CPE-ODU-PRO-
SA-ffBMAX-CPE-IDU-1D
(indoor)hub /
switch
PC
PC
ALVR-VG-1DnV-C
ALVR-VG-1DnV-C6 5
43
21
7
Indoor
BMAX-CPE-ODU-PRO-
SE-ff
802.11g
PCPC
PC PC
PC
BMAX-CPE-IDU-NG-4D1W(indoor)
FunctionLabel No
When lit - the SU is connected with an AUWIRELESS LED1
When lit - self test passed and Ethernet connection established with the ODUETH LED2
When lit - SU-IDU power is OKPWR LED3RJ-45 connector supports 10/100 BASE-T and
connected to the customer LANETHERNET Connector4
Ethernet port activity LED when blinking -Ethernet activity at the Ethernet port-5
Ethernet port integrity LED when lit - Ethernet physical layer is OK-6
3 pin AC connector to the AC mains-7
-
6Subscriber Unit Indoor
Ethernet 10/100 Mbps
BMAX-CPE-ODU-PRO-
SA-ffBMAX-CPE-IDU-1D
(indoor)hub /
switch
PC
PC
ALVR-VG-1DnV-C
ALVR-VG-1DnV-C
8
Indoor
BMAX-CPE-ODU-PRO-
SE-ff
802.11g
PCPC
PC PC
PC
BMAX-CPE-IDU-NG-4D1W(indoor)
FunctionLabel NoRJ-45 connector supports 10/100
BASE-T and connects to the SU-ODURADIO
Connector8
Warning: Connecting the radio interface to anEthernet port may damage the equipment
-
7Networking Gateway (NG)
NG ports: 1 * Ethernet ODU (+ DC voltage) 4 * Ethernet 10/100 BaseT
1 * IEEE 802.11 b/g (AP) Routing functionality
Powered from the mains
Ethernet 10/100 Mbps
BMAX-CPE-ODU-PRO-
SA-ffBMAX-CPE-IDU-1D
(indoor)hub /
switch
PC
PC
ALVR-VG-1DnV-C
ALVR-VG-1DnV-C
Powered from the mains
Connects to ODU via a category 5E Ethernet cable:
Ethernet data
Power (54 VDC) Control signals to ODU
Status indications from ODU
Designed for remote management using either internal web server or SNMP
Indoor
BMAX-CPE-ODU-PRO-
SE-ff
802.11g
PCPC
PC PC
PC
BMAX-CPE-IDU-NG-4D1W(indoor)
-
8Networking Gateway (NG)
5678910
2 431
Ethernet 10/100 Mbps
BMAX-CPE-ODU-PRO-
SA-ffBMAX-CPE-IDU-1D
(indoor)hub /
switch
PC
PC
ALVR-VG-1DnV-C
ALVR-VG-1DnV-C
FunctionLabel No
Indoor
BMAX-CPE-ODU-PRO-
SE-ff
802.11g
PCPC
PC PC
PC
BMAX-CPE-IDU-NG-4D1W(indoor)
FunctionLabel NoOn - the ODU port is connected to the ODU
Blinking - the ODU port is sending or receiving dataODU
LINK/ACT1
On - An active station is connected to the corresponding LAN port
Blinking - The corresponding LAN port is sending or receiving data
LAN LINK/ACT2
On - A printer is connected to the USB portBlinking - The USB port is sending or receiving
data USB3
On - Power is OKPOWER4Used to reset the unit or to set the unit to factory
defaultRESET
BUTTON5
Blinking - Wireless LAN port sending or receiving dataWLAN6
-
9Networking Gateway (NG)
5678910
2 431
Ethernet 10/100 Mbps
BMAX-CPE-ODU-PRO-
SA-ffBMAX-CPE-IDU-1D
(indoor)hub /
switch
PC
PC
ALVR-VG-1DnV-C
ALVR-VG-1DnV-C
FunctionLabel No
Indoor
BMAX-CPE-ODU-PRO-
SE-ff
802.11g
PCPC
PC PC
PC
BMAX-CPE-IDU-NG-4D1W(indoor)
FunctionLabel NoBlinking - The unit functioning properlySTATUS7
Off - Data rate is 10 Mbps on the corresponding LAN port
On - Data rate is 100 Mbps on the corresponding LAN port
LAN SPEED 10/100
8
Off - Data rate is 10 Mbps on the ODU port On - Data rate is 100 Mbps on the ODU port
ODU 10/1009
On - The ODU is connected with an AU WLINK10
-
10Networking Gateway (NG)Ethernet
10/100 MbpsBMAX-CPE-ODU-PRO-
SA-ffBMAX-CPE-IDU-1D
(indoor)hub /
switch
PC
PC
ALVR-VG-1DnV-C
ALVR-VG-1DnV-C
FunctionLabel No
56
2 431
Indoor
BMAX-CPE-ODU-PRO-
SE-ff
802.11g
PCPC
PC PC
PC
BMAX-CPE-IDU-NG-4D1W(indoor)
FunctionLabel No
An SMA connector for the WLAN antenna Antenna Port1
LAN ports for networked computers and other devices
Ports 1-42
Connection to the ODU. Carries Ethernet, Power (55 VDC) and signaling ODU3
DC Power Inlet from Power Transformer POWER4
Used to reset the ODURESET ODU5
USB port to connect a printerUSB6
-
11Subscriber Unit Outdoor PRO-S CPE
Contains the modem, radio, data processing and management components
Utilize Intel WiMAX Connection 2250 Rosedale 2 802.16e (mobile WIMAX)- ready SDRAM 32M / Flash 16M
The Air Protocol Detection (APD) support automatic switching to the appropriate air protocol, allowing simple upgrade to mobile WiMAX.
Contains an integral high-gain flat antenna or a connection to an external antenna
Ethernet 10/100 Mbps
BMAX-CPE-ODU-PRO-
SA-ffBMAX-CPE-IDU-1D
(indoor)hub /
switch
PC
PC
ALVR-VG-1DnV-C
ALVR-VG-1DnV-C
connection to an external antenna
Antenna characteristics
Gain - 13dBi (2.3Ghz), 14dBi (2.5Ghz), 17dBi (3.5Ghz), 16.5 (3.3Ghz)
Azimuth BW - 23(2.x), 20(3.x) Elevation BW - 27(2.x), 20(3.x)
Support all bands
Contains SAU connector
Output power (at antenna port) 19 1 dBm Supports both vertical and horizontal polarizations,
depending on the way it is installed
Indoor
802.11g
PCPC
PC PC
PC
BMAX-CPE-IDU-NG-4D1W(indoor)
BMAX-CPE-ODU-PRO-
SE-ff
-
12Subscriber Unit Outdoor - PRO CPE S
Ethernet 10/100 Mbps
BMAX-CPE-ODU-PRO-
SA-ffBMAX-CPE-IDU-1D
(indoor)hub /
switch
PC
PC
ALVR-VG-1DnV-C
ALVR-VG-1DnV-C
21
Indoor
802.11g
PCPC
PC PC
PC
BMAX-CPE-IDU-NG-4D1W(indoor)
BMAX-CPE-ODU-PRO-
SE-ff
FunctionLabel NoUSB connector to connect Subscriber
Alignment UnitSAU
Connector1
RJ-45 connector supports 10/100 BASE-T and connects to the SU-ODU
IDU COM Connecter2
-
13Subscriber Alignment Unit (SAU)Ethernet
10/100 MbpsBMAX-CPE-ODU-PRO-
SA-ffBMAX-CPE-IDU-1D
(indoor)hub /
switch
PC
PC
ALVR-VG-1DnV-C
ALVR-VG-1DnV-C
4
1
2
3
Indoor
802.11g
PCPC
PC PC
PC
BMAX-CPE-IDU-NG-4D1W(indoor)
BMAX-CPE-ODU-PRO-
SE-ff
FunctionLabel NoWhen lit - SU-ODU failureALARM LED1
When lit - SU-ODU power is OKPWR LED2When lit - self test passed and Ethernet connection established with the ODUETH LED3
Wireless link status and signal quality Indication LINK QUALITY
Bar Display4
-
14Subscriber Alignment Unit (SAU)
The link quality bar display consists of ten LEDs as follows
Ethernet 10/100 Mbps
BMAX-CPE-ODU-PRO-
SA-ffBMAX-CPE-IDU-1D
(indoor)hub /
switch
PC
PC
ALVR-VG-1DnV-C
ALVR-VG-1DnV-CDescriptionLED NumbersWireless link is up
10 9 8 7 6 5 4 3 2 1
WLNK
Indoor
802.11g
PCPC
PC PC
PC
BMAX-CPE-IDU-NG-4D1W(indoor)
BMAX-CPE-ODU-PRO-
SE-ff
Wireless link is upThe SU is connected and receives services from
the AU (Network Entry completed) 1
5 dB SNR < 10 dBUp to 210 dB SNR < 15 dBUp to 315 dB SNR < 20 dBUp to 420 dB SNR < 24 dBUp to 5
SNR 24 and RSSI < -75Up to 6SNR 24 and RSSI -75Up to 7SNR 24 and RSSI -70Up to 8SNR 24 and RSSI -60Up to 9RSSI -20 (saturation)Up to 10
-
15New SAU LOK (Led On Key)Ethernet
10/100 MbpsBMAX-CPE-ODU-PRO-
SA-ffBMAX-CPE-IDU-1D
(indoor)hub /
switch
PC
PC
ALVR-VG-1DnV-C
ALVR-VG-1DnV-C
Unit is not repairable
Unit is not water resistant
Order Options
SAU-LOK 10-Pack
SAU-LOK 1-Pack
Indoor
802.11g
PCPC
PC PC
PC
BMAX-CPE-IDU-NG-4D1W(indoor)
BMAX-CPE-ODU-PRO-
SE-ff
FunctionLabel When lit - SU-ODU failureALARM LED
When lit - SU-ODU power is OKPWR LEDWhen lit - self test passed and Ethernet connection
established with the ODUETH LED
Wireless link is upThe SU is connected and receives services from the AU
(Network Entry completed) WLNK
Wireless link status and signal quality Indication LINK QUALITY Bar Display
-
16New SAU LOK (Led On Key)
WLNK
12345678
FunctionLabel
- The SU is not connected with a Base Station.Off
9
Ethernet 10/100 Mbps
BMAX-CPE-ODU-PRO-
SA-ffBMAX-CPE-IDU-1D
(indoor)hub /
switch
PC
PC
ALVR-VG-1DnV-C
BMAX-CPE-IDU-NG-4D1W
ALVR-VG-1DnV-C
BMAX-CPE-ODU-PRO-
The link quality bar display consists of ten LEDs as follows
- CPE is connected with a base station.Orange
- Authentication reject. (From version 4.1)The reason is indicated by Link quality LEDS 7-9.
Blinking Orange
- User Name not found / Wrong Password / Maximum number of multiple sessions has been exceeded.
LEDs 7, 8, 9
illuminate
- Duplicate User Name/Common Name in NPU database.LEDs 8, 9 illuminate
- Authentication timeout: the NPU does not have connection to the defined Radius Server(s), or Shared Secret mismatch between the NPU and Radius Server(s).
LED 9 illuminates
Indoor
802.11g
PCPC
PC PC
PC
BMAX-CPE-IDU-NG-4D1W(indoor)ODU-PRO-SE-ff
-
17New SAU LOK (Led On Key)
FunctionLED Nr. 5 dB SNR < 10 dBUp to 1
10 dB SNR < 15 dBUp to 215 dB SNR < 20 dBUp to 3
Ethernet 10/100 Mbps
BMAX-CPE-ODU-PRO-
SA-ffBMAX-CPE-IDU-1D
(indoor)hub /
switch
PC
PC
ALVR-VG-1DnV-C
ALVR-VG-1DnV-C
20 dB SNR < 24 dBUp to 4SNR 24 and RSSI < -75Up to 5SNR 24 and RSSI -75Up to 6SNR 24 and RSSI -70Up to 7SNR 24 and RSSI -60Up to 8RSSI -20 (saturation)Up to 9
Indoor
802.11g
PCPC
PC PC
PC
BMAX-CPE-IDU-NG-4D1W(indoor)
BMAX-CPE-ODU-PRO-
SE-ff
-
18Subscriber Unit Outdoor Spec for 2.xGHz
3.5MHz 5MHz
Rate Nr Modulation Bit rate
Sensitivity [dBm] @ PER 1e-2
Bit rate Sensitivity [dBm] @ PER 1e-2
1 BPSK 1.41 Mbps -98 1.92Mbps -96 2 QPSK 2.83 Mbps -95 3.804Mbps -93
Ethernet 10/100 Mbps
BMAX-CPE-ODU-PRO-
SA-ffBMAX-CPE-IDU-1D
(indoor)hub /
switch
PC
PC
ALVR-VG-1DnV-C
ALVR-VG-1DnV-C
2 QPSK 2.83 Mbps -95 3.804Mbps -93 3 QPSK 4.204 Mbps -92 5.76Mbps -89 4 QAM 16 5.606 Mbps -89 7.68Mbps -87 5 QAM 16 8.47 Mbps -86 11.52Mbps -84 6 QAM 64 2/3 11.21 Mbps
-81 15.36Mbps -79
7 QAM 64 12.61 Mbps -80 17.28Mbps -78 Indoor
802.11g
PCPC
PC PC
PC
BMAX-CPE-IDU-NG-4D1W(indoor)
BMAX-CPE-ODU-PRO-
SE-ff
-
19IDU-ODU Cable
A category 5e Ethernet cable
Carries the Ethernet data between the two units
Carries power (-54 VDC) and control signals to the SU-ODU
Carries status indications from the SU-ODU
The length of the Indoor-to-Outdoor cable, plus
Ethernet 10/100 Mbps
BMAX-CPE-ODU-PRO-
SA-ffBMAX-CPE-IDU-1D
(indoor)hub /
switch
PC
PC
ALVR-VG-1DnV-C
ALVR-VG-1DnV-C
The length of the Indoor-to-Outdoor cable, plus the Ethernet cable connecting the SU to the data equipment, should not exceed 100 meters/328 feet
Use only Category 5E cables from approved manufacturers
Indoor
802.11g
PCPC
PC PC
PC
BMAX-CPE-IDU-NG-4D1W(indoor)
BMAX-CPE-ODU-PRO-
SE-ff
see catalogAlvarion612098Superior Cables LTDH5E-00481HES Cabling SystemsTSM2404A0DSouthbay Holdings Limited 8393204101Teldor
-
20Subscriber Unit Self Install (SU-Si)
Compact, single box, Indoor CPE Utilize Intel WiMAX Connection 2250
Rosedale 2 (802.16e ready) SDRAM 32M (old 16M) / Flash 16M (old 4M)
SU antenna selection automatic & manual Detach antenna kit and possible mounting
scenarios (window, mounting kit)
Indoor
Ethernet 10/100 Mbps
BMAX-CPE-Si-E-3.5
(indoor)hub /
switch
PC
PC
ALVR-VG-1DnV-C
scenarios (window, mounting kit) Expected coverage is limited than Pro CPE Recommended to install the unit next to a
window facing the BST Ethernet or USB connector Configuration through Smart Card
-
21Subscriber Unit Self Install (SU-Si)
Contains the modem, radio, data processing and management components
Contains a beam switching array of 6 antennas
All SU-Si types (2.x & 3.x) support all bands Output power (antenna port):
Indoor
Ethernet 10/100 Mbps
BMAX-CPE-Si-E-(indoor)
hub / switch
PC
PC
ALVR-VG-1DnV-C
Output power (antenna port): 21dBm @ 5Ghz
23dBm @ 3.5Ghz
24dBm @ 2.5Ghz
23dBm @ 2.3Ghz Smart CardN/A
-
22Subscriber Unit Self Install (SU-Si)
8
Indoor
Ethernet 10/100 Mbps
BMAX-CPE-Si-E-(indoor)
hub / switch
PC
PC
ALVR-VG-1DnV-C
1
FunctionLabel NoStatus IndicationStatus LED1
Indicates the quality of the received signalSIGNAL LEDs2Ethernet port activity LED when blinking - Ethernet activity
at the Ethernet port-3
Ethernet port integrity LED when lit - Ethernet physical layer is OK-4
Reset button removed starting v4.5.1-5DC power jack7.3V DC6
RJ-45 connector supports 10/100 BASE-T or USB connected to the customer LAN
ETHERNET/USB Connector7
Initiating Scanning ModeScan Button8
8
2
1
7
6
3
4
5
-
23Subscriber Unit Self Install (SU-Si)
Indoor
Ethernet 10/100 Mbps
BMAX-CPE-Si-E-(indoor)
hub / switch
PC
PC
ALVR-VG-1DnV-C
FunctionStatus LED- CPE is not powered or power failure.Off
- CPE is connected with a base station.Green- CPE failure.Red- After power-up (if power supply is ok) until start of self test, after passing self-test until network entry is completed, or upon Orange until network entry is completed, or upon restarting the network entry process.- CPE is being set to Factory Defaults (during 6 seconds after pressing the RESET button for more than 5seconds).
Blinking Orange
- In case SIGNAL LEDs 5, 6 and 7 are on: Authentication reject by RADIUS server.- In case SIGNAL LEDS 6 and 7 are on: Rejected by Base Station (Duplicate SU Name in database).- In case LED 7 is on: Authentication Timeout, re-authentication failure (connection to RADIUS server lost).
Blinking Green
-
24Subscriber Unit Self Install (SU-Si)
FunctionLED Nr. 5 dB SNR < 10 dBUp to 110 dB SNR < 15 dBUp to 2
Indoor
Ethernet 10/100 Mbps
BMAX-CPE-Si-E-(indoor)
hub / switch
PC
PC
ALVR-VG-1DnV-C
10 dB SNR < 15 dBUp to 215 dB SNR < 20 dBUp to 320 dB SNR < 24 dBUp to 4
SNR 24 and RSSI < -75Up to 5SNR 24 and RSSI -75Up to 6SNR 24 and RSSI -70Up to 7SNR 24 and RSSI -60Up to 8RSSI -20 (saturation)Up to 9
-
25Subscriber Unit Self Install (SU-Si)
Indoor
Ethernet 10/100 Mbps
BMAX-CPE-Si-E-(indoor)
hub / switch
PC
PC
ALVR-VG-1DnV-C
FunctionLabel
Press for less than 3 seconds:Initiate Best AU selection process without full scanning. It means that the CPE scans only the AUs detected in the last full scan. The LEDs will be blinking scan. The LEDs will be blinking as mentioned above for Best AU operation.
Press for 3 seconds or more:Initiate full scan, prepare an updated the best AU list and select the best AU. The LEDs will be blinking as mentioned above for full scan operation.
Scan Button
-
26Subscriber Unit Self Install (SU-Si)
The following drawings describes the embedded antennas main beam direction
External antenna is referred as ANT 0
The operational antenna is selected from the SI menus
Indoor
Ethernet 10/100 Mbps
BMAX-CPE-Si-E-3.5
(indoor)hub /
switch
PC
PC
ALVR-VG-1DnV-C
ANT 1 ANT 3
ANT 0
-
27Subscriber Unit Self Install (SU-Si)
Identification of Rosedale 2 by SU Type (Valid for Si&PRO-S)
Identification of USB/Eth model by Interface Type (USB/Eth)
USB model requires installation of driver that supplied with the unit (Win 98SE,WinME, supplied with the unit (Win 98SE,WinME, Win2K, WinXP, WinXP 64bits)
USB model has two MAC Addresses: MAC A MAC that the PC extracts from
the Si as the PCs USB controller has no MAC (e.g, NIC). This MAC can be viewed in the ARP table of the PC
MAC B The Rosedale MAC used for authentication with the NPU. This MAC is displayed in the SU menu
-
28Subscriber Unit Self Install (SU-Si)
FREQUENCY RANGE
2.3 - 2.7 GHz
GAIN 9.5 -10.5dBi VSWR 2:1 (max) 3dB AZIMUTH BEAMWIDTH
70 (typ)BEAMWIDTH3dB Elevation BEAMWIDTH
20 (typ)
POLARIZATION Linear VerticalF/B RATIO -20dB (typ)INPUT IMPEDANCE
50 (ohm)
-
29SU-Si 3.x Window Antenna
FREQUENCY RANGE
3.4 - 3.7 GHz
GAIN 12dBi VSWR 2:1 (max) 3dB AZIMUTH BEAMWIDTH
77 (typ)BEAMWIDTH3dB Elevation BEAMWIDTH
17 (typ)
POLARIZATION Linear VerticalF/B RATIO -18dB (typ)INPUT IMPEDANCE
50 (ohm)
-
New BreezeMAX Si Business Models
-
31Smart Card
Plug&Play - The customer just plug the Smart Card to the Si and start to work
The CPE is purchase in a public location
Smart Cards are burnt by the operator
Ver. 09-04-15
burnt by the operator
-
32Smart Card
Smart Card Writer/Reader Application User Information Tab
Enables to enter the user information necessary for proper authentication
The User Name and Password are editable to the Sales user only. When logged in as Administrator, these parameters are read only
User Name and Password provided by operatorSales Administrator
Ver. 09-04-15
Sales Administrator
-
33WiMAX Modem Application
An easy to follow InstallShield Wizard On screen instructions Language Selection User Name and Password supplied by
operator Choosing location
Ver. 09-04-15
-
34WiMAX Modem Application
Management Status Tab Shows network connection
status Graphical display Continuous updates of link
parameters and quality, counters etc.
User name,
Ver. 09-04-15
User name, connection status,
SW ver 1 2 3
1
2
3
Connection between PC and WiMAX Modem
Indication of correct Modem-Base Station definitions
Connection to an authentication mechanism (radius server/NPU)
-
35WiMAX Modem Application
Management Settings Tab Changeable parameters:
User Info, BS/AU ID, BW, Scanning Freq, Antenna, Rx Atten, Eth port settings.
Customization option
Ver. 09-04-15
-
Thank You