03 - BreezeMAX - System Architecture CPE - 09-11-16 - Ver

download 03 - BreezeMAX - System Architecture CPE - 09-11-16 - Ver

of 36

description

ALVARION CPE

Transcript of 03 - BreezeMAX - System Architecture CPE - 09-11-16 - Ver

  • CPE Architecture

    Copyright Alvarion Ltd.

  • 2Objectives

    Upon completion of this module students will know the following: Subscriber components

    Mechanical concept Led indications Specifications

  • 3Subscriber Unit Indoor

  • 4Subscriber Unit Indoor

    The Subscriber Unit (SU) installed at the customer premises

    Ports

    1 * 10/100BaseT Ethernet

    Ethernet 10/100 Mbps

    BMAX-CPE-ODU-PRO-

    SA-ffBMAX-CPE-IDU-1D

    (indoor)hub /

    switch

    PC

    PC

    ALVR-VG-1DnV-C

    ALVR-VG-1DnV-C

    1 * Ethernet "Radio" port to ODU (+DC voltage)

    Bridge functionality

    Up to 512 MAC addresses behind the SU

    The SU is powered from the mains

    Indoor

    BMAX-CPE-ODU-PRO-

    SE-ff

    802.11g

    PCPC

    PC PC

    PC

    BMAX-CPE-IDU-NG-4D1W(indoor)

    For the detailed information of the next slides please refer to theBreezeMAX CPEsProduct Manual

  • 5Subscriber Unit Indoor

    Ethernet 10/100 Mbps

    BMAX-CPE-ODU-PRO-

    SA-ffBMAX-CPE-IDU-1D

    (indoor)hub /

    switch

    PC

    PC

    ALVR-VG-1DnV-C

    ALVR-VG-1DnV-C6 5

    43

    21

    7

    Indoor

    BMAX-CPE-ODU-PRO-

    SE-ff

    802.11g

    PCPC

    PC PC

    PC

    BMAX-CPE-IDU-NG-4D1W(indoor)

    FunctionLabel No

    When lit - the SU is connected with an AUWIRELESS LED1

    When lit - self test passed and Ethernet connection established with the ODUETH LED2

    When lit - SU-IDU power is OKPWR LED3RJ-45 connector supports 10/100 BASE-T and

    connected to the customer LANETHERNET Connector4

    Ethernet port activity LED when blinking -Ethernet activity at the Ethernet port-5

    Ethernet port integrity LED when lit - Ethernet physical layer is OK-6

    3 pin AC connector to the AC mains-7

  • 6Subscriber Unit Indoor

    Ethernet 10/100 Mbps

    BMAX-CPE-ODU-PRO-

    SA-ffBMAX-CPE-IDU-1D

    (indoor)hub /

    switch

    PC

    PC

    ALVR-VG-1DnV-C

    ALVR-VG-1DnV-C

    8

    Indoor

    BMAX-CPE-ODU-PRO-

    SE-ff

    802.11g

    PCPC

    PC PC

    PC

    BMAX-CPE-IDU-NG-4D1W(indoor)

    FunctionLabel NoRJ-45 connector supports 10/100

    BASE-T and connects to the SU-ODURADIO

    Connector8

    Warning: Connecting the radio interface to anEthernet port may damage the equipment

  • 7Networking Gateway (NG)

    NG ports: 1 * Ethernet ODU (+ DC voltage) 4 * Ethernet 10/100 BaseT

    1 * IEEE 802.11 b/g (AP) Routing functionality

    Powered from the mains

    Ethernet 10/100 Mbps

    BMAX-CPE-ODU-PRO-

    SA-ffBMAX-CPE-IDU-1D

    (indoor)hub /

    switch

    PC

    PC

    ALVR-VG-1DnV-C

    ALVR-VG-1DnV-C

    Powered from the mains

    Connects to ODU via a category 5E Ethernet cable:

    Ethernet data

    Power (54 VDC) Control signals to ODU

    Status indications from ODU

    Designed for remote management using either internal web server or SNMP

    Indoor

    BMAX-CPE-ODU-PRO-

    SE-ff

    802.11g

    PCPC

    PC PC

    PC

    BMAX-CPE-IDU-NG-4D1W(indoor)

  • 8Networking Gateway (NG)

    5678910

    2 431

    Ethernet 10/100 Mbps

    BMAX-CPE-ODU-PRO-

    SA-ffBMAX-CPE-IDU-1D

    (indoor)hub /

    switch

    PC

    PC

    ALVR-VG-1DnV-C

    ALVR-VG-1DnV-C

    FunctionLabel No

    Indoor

    BMAX-CPE-ODU-PRO-

    SE-ff

    802.11g

    PCPC

    PC PC

    PC

    BMAX-CPE-IDU-NG-4D1W(indoor)

    FunctionLabel NoOn - the ODU port is connected to the ODU

    Blinking - the ODU port is sending or receiving dataODU

    LINK/ACT1

    On - An active station is connected to the corresponding LAN port

    Blinking - The corresponding LAN port is sending or receiving data

    LAN LINK/ACT2

    On - A printer is connected to the USB portBlinking - The USB port is sending or receiving

    data USB3

    On - Power is OKPOWER4Used to reset the unit or to set the unit to factory

    defaultRESET

    BUTTON5

    Blinking - Wireless LAN port sending or receiving dataWLAN6

  • 9Networking Gateway (NG)

    5678910

    2 431

    Ethernet 10/100 Mbps

    BMAX-CPE-ODU-PRO-

    SA-ffBMAX-CPE-IDU-1D

    (indoor)hub /

    switch

    PC

    PC

    ALVR-VG-1DnV-C

    ALVR-VG-1DnV-C

    FunctionLabel No

    Indoor

    BMAX-CPE-ODU-PRO-

    SE-ff

    802.11g

    PCPC

    PC PC

    PC

    BMAX-CPE-IDU-NG-4D1W(indoor)

    FunctionLabel NoBlinking - The unit functioning properlySTATUS7

    Off - Data rate is 10 Mbps on the corresponding LAN port

    On - Data rate is 100 Mbps on the corresponding LAN port

    LAN SPEED 10/100

    8

    Off - Data rate is 10 Mbps on the ODU port On - Data rate is 100 Mbps on the ODU port

    ODU 10/1009

    On - The ODU is connected with an AU WLINK10

  • 10Networking Gateway (NG)Ethernet

    10/100 MbpsBMAX-CPE-ODU-PRO-

    SA-ffBMAX-CPE-IDU-1D

    (indoor)hub /

    switch

    PC

    PC

    ALVR-VG-1DnV-C

    ALVR-VG-1DnV-C

    FunctionLabel No

    56

    2 431

    Indoor

    BMAX-CPE-ODU-PRO-

    SE-ff

    802.11g

    PCPC

    PC PC

    PC

    BMAX-CPE-IDU-NG-4D1W(indoor)

    FunctionLabel No

    An SMA connector for the WLAN antenna Antenna Port1

    LAN ports for networked computers and other devices

    Ports 1-42

    Connection to the ODU. Carries Ethernet, Power (55 VDC) and signaling ODU3

    DC Power Inlet from Power Transformer POWER4

    Used to reset the ODURESET ODU5

    USB port to connect a printerUSB6

  • 11Subscriber Unit Outdoor PRO-S CPE

    Contains the modem, radio, data processing and management components

    Utilize Intel WiMAX Connection 2250 Rosedale 2 802.16e (mobile WIMAX)- ready SDRAM 32M / Flash 16M

    The Air Protocol Detection (APD) support automatic switching to the appropriate air protocol, allowing simple upgrade to mobile WiMAX.

    Contains an integral high-gain flat antenna or a connection to an external antenna

    Ethernet 10/100 Mbps

    BMAX-CPE-ODU-PRO-

    SA-ffBMAX-CPE-IDU-1D

    (indoor)hub /

    switch

    PC

    PC

    ALVR-VG-1DnV-C

    ALVR-VG-1DnV-C

    connection to an external antenna

    Antenna characteristics

    Gain - 13dBi (2.3Ghz), 14dBi (2.5Ghz), 17dBi (3.5Ghz), 16.5 (3.3Ghz)

    Azimuth BW - 23(2.x), 20(3.x) Elevation BW - 27(2.x), 20(3.x)

    Support all bands

    Contains SAU connector

    Output power (at antenna port) 19 1 dBm Supports both vertical and horizontal polarizations,

    depending on the way it is installed

    Indoor

    802.11g

    PCPC

    PC PC

    PC

    BMAX-CPE-IDU-NG-4D1W(indoor)

    BMAX-CPE-ODU-PRO-

    SE-ff

  • 12Subscriber Unit Outdoor - PRO CPE S

    Ethernet 10/100 Mbps

    BMAX-CPE-ODU-PRO-

    SA-ffBMAX-CPE-IDU-1D

    (indoor)hub /

    switch

    PC

    PC

    ALVR-VG-1DnV-C

    ALVR-VG-1DnV-C

    21

    Indoor

    802.11g

    PCPC

    PC PC

    PC

    BMAX-CPE-IDU-NG-4D1W(indoor)

    BMAX-CPE-ODU-PRO-

    SE-ff

    FunctionLabel NoUSB connector to connect Subscriber

    Alignment UnitSAU

    Connector1

    RJ-45 connector supports 10/100 BASE-T and connects to the SU-ODU

    IDU COM Connecter2

  • 13Subscriber Alignment Unit (SAU)Ethernet

    10/100 MbpsBMAX-CPE-ODU-PRO-

    SA-ffBMAX-CPE-IDU-1D

    (indoor)hub /

    switch

    PC

    PC

    ALVR-VG-1DnV-C

    ALVR-VG-1DnV-C

    4

    1

    2

    3

    Indoor

    802.11g

    PCPC

    PC PC

    PC

    BMAX-CPE-IDU-NG-4D1W(indoor)

    BMAX-CPE-ODU-PRO-

    SE-ff

    FunctionLabel NoWhen lit - SU-ODU failureALARM LED1

    When lit - SU-ODU power is OKPWR LED2When lit - self test passed and Ethernet connection established with the ODUETH LED3

    Wireless link status and signal quality Indication LINK QUALITY

    Bar Display4

  • 14Subscriber Alignment Unit (SAU)

    The link quality bar display consists of ten LEDs as follows

    Ethernet 10/100 Mbps

    BMAX-CPE-ODU-PRO-

    SA-ffBMAX-CPE-IDU-1D

    (indoor)hub /

    switch

    PC

    PC

    ALVR-VG-1DnV-C

    ALVR-VG-1DnV-CDescriptionLED NumbersWireless link is up

    10 9 8 7 6 5 4 3 2 1

    WLNK

    Indoor

    802.11g

    PCPC

    PC PC

    PC

    BMAX-CPE-IDU-NG-4D1W(indoor)

    BMAX-CPE-ODU-PRO-

    SE-ff

    Wireless link is upThe SU is connected and receives services from

    the AU (Network Entry completed) 1

    5 dB SNR < 10 dBUp to 210 dB SNR < 15 dBUp to 315 dB SNR < 20 dBUp to 420 dB SNR < 24 dBUp to 5

    SNR 24 and RSSI < -75Up to 6SNR 24 and RSSI -75Up to 7SNR 24 and RSSI -70Up to 8SNR 24 and RSSI -60Up to 9RSSI -20 (saturation)Up to 10

  • 15New SAU LOK (Led On Key)Ethernet

    10/100 MbpsBMAX-CPE-ODU-PRO-

    SA-ffBMAX-CPE-IDU-1D

    (indoor)hub /

    switch

    PC

    PC

    ALVR-VG-1DnV-C

    ALVR-VG-1DnV-C

    Unit is not repairable

    Unit is not water resistant

    Order Options

    SAU-LOK 10-Pack

    SAU-LOK 1-Pack

    Indoor

    802.11g

    PCPC

    PC PC

    PC

    BMAX-CPE-IDU-NG-4D1W(indoor)

    BMAX-CPE-ODU-PRO-

    SE-ff

    FunctionLabel When lit - SU-ODU failureALARM LED

    When lit - SU-ODU power is OKPWR LEDWhen lit - self test passed and Ethernet connection

    established with the ODUETH LED

    Wireless link is upThe SU is connected and receives services from the AU

    (Network Entry completed) WLNK

    Wireless link status and signal quality Indication LINK QUALITY Bar Display

  • 16New SAU LOK (Led On Key)

    WLNK

    12345678

    FunctionLabel

    - The SU is not connected with a Base Station.Off

    9

    Ethernet 10/100 Mbps

    BMAX-CPE-ODU-PRO-

    SA-ffBMAX-CPE-IDU-1D

    (indoor)hub /

    switch

    PC

    PC

    ALVR-VG-1DnV-C

    BMAX-CPE-IDU-NG-4D1W

    ALVR-VG-1DnV-C

    BMAX-CPE-ODU-PRO-

    The link quality bar display consists of ten LEDs as follows

    - CPE is connected with a base station.Orange

    - Authentication reject. (From version 4.1)The reason is indicated by Link quality LEDS 7-9.

    Blinking Orange

    - User Name not found / Wrong Password / Maximum number of multiple sessions has been exceeded.

    LEDs 7, 8, 9

    illuminate

    - Duplicate User Name/Common Name in NPU database.LEDs 8, 9 illuminate

    - Authentication timeout: the NPU does not have connection to the defined Radius Server(s), or Shared Secret mismatch between the NPU and Radius Server(s).

    LED 9 illuminates

    Indoor

    802.11g

    PCPC

    PC PC

    PC

    BMAX-CPE-IDU-NG-4D1W(indoor)ODU-PRO-SE-ff

  • 17New SAU LOK (Led On Key)

    FunctionLED Nr. 5 dB SNR < 10 dBUp to 1

    10 dB SNR < 15 dBUp to 215 dB SNR < 20 dBUp to 3

    Ethernet 10/100 Mbps

    BMAX-CPE-ODU-PRO-

    SA-ffBMAX-CPE-IDU-1D

    (indoor)hub /

    switch

    PC

    PC

    ALVR-VG-1DnV-C

    ALVR-VG-1DnV-C

    20 dB SNR < 24 dBUp to 4SNR 24 and RSSI < -75Up to 5SNR 24 and RSSI -75Up to 6SNR 24 and RSSI -70Up to 7SNR 24 and RSSI -60Up to 8RSSI -20 (saturation)Up to 9

    Indoor

    802.11g

    PCPC

    PC PC

    PC

    BMAX-CPE-IDU-NG-4D1W(indoor)

    BMAX-CPE-ODU-PRO-

    SE-ff

  • 18Subscriber Unit Outdoor Spec for 2.xGHz

    3.5MHz 5MHz

    Rate Nr Modulation Bit rate

    Sensitivity [dBm] @ PER 1e-2

    Bit rate Sensitivity [dBm] @ PER 1e-2

    1 BPSK 1.41 Mbps -98 1.92Mbps -96 2 QPSK 2.83 Mbps -95 3.804Mbps -93

    Ethernet 10/100 Mbps

    BMAX-CPE-ODU-PRO-

    SA-ffBMAX-CPE-IDU-1D

    (indoor)hub /

    switch

    PC

    PC

    ALVR-VG-1DnV-C

    ALVR-VG-1DnV-C

    2 QPSK 2.83 Mbps -95 3.804Mbps -93 3 QPSK 4.204 Mbps -92 5.76Mbps -89 4 QAM 16 5.606 Mbps -89 7.68Mbps -87 5 QAM 16 8.47 Mbps -86 11.52Mbps -84 6 QAM 64 2/3 11.21 Mbps

    -81 15.36Mbps -79

    7 QAM 64 12.61 Mbps -80 17.28Mbps -78 Indoor

    802.11g

    PCPC

    PC PC

    PC

    BMAX-CPE-IDU-NG-4D1W(indoor)

    BMAX-CPE-ODU-PRO-

    SE-ff

  • 19IDU-ODU Cable

    A category 5e Ethernet cable

    Carries the Ethernet data between the two units

    Carries power (-54 VDC) and control signals to the SU-ODU

    Carries status indications from the SU-ODU

    The length of the Indoor-to-Outdoor cable, plus

    Ethernet 10/100 Mbps

    BMAX-CPE-ODU-PRO-

    SA-ffBMAX-CPE-IDU-1D

    (indoor)hub /

    switch

    PC

    PC

    ALVR-VG-1DnV-C

    ALVR-VG-1DnV-C

    The length of the Indoor-to-Outdoor cable, plus the Ethernet cable connecting the SU to the data equipment, should not exceed 100 meters/328 feet

    Use only Category 5E cables from approved manufacturers

    Indoor

    802.11g

    PCPC

    PC PC

    PC

    BMAX-CPE-IDU-NG-4D1W(indoor)

    BMAX-CPE-ODU-PRO-

    SE-ff

    see catalogAlvarion612098Superior Cables LTDH5E-00481HES Cabling SystemsTSM2404A0DSouthbay Holdings Limited 8393204101Teldor

  • 20Subscriber Unit Self Install (SU-Si)

    Compact, single box, Indoor CPE Utilize Intel WiMAX Connection 2250

    Rosedale 2 (802.16e ready) SDRAM 32M (old 16M) / Flash 16M (old 4M)

    SU antenna selection automatic & manual Detach antenna kit and possible mounting

    scenarios (window, mounting kit)

    Indoor

    Ethernet 10/100 Mbps

    BMAX-CPE-Si-E-3.5

    (indoor)hub /

    switch

    PC

    PC

    ALVR-VG-1DnV-C

    scenarios (window, mounting kit) Expected coverage is limited than Pro CPE Recommended to install the unit next to a

    window facing the BST Ethernet or USB connector Configuration through Smart Card

  • 21Subscriber Unit Self Install (SU-Si)

    Contains the modem, radio, data processing and management components

    Contains a beam switching array of 6 antennas

    All SU-Si types (2.x & 3.x) support all bands Output power (antenna port):

    Indoor

    Ethernet 10/100 Mbps

    BMAX-CPE-Si-E-(indoor)

    hub / switch

    PC

    PC

    ALVR-VG-1DnV-C

    Output power (antenna port): 21dBm @ 5Ghz

    23dBm @ 3.5Ghz

    24dBm @ 2.5Ghz

    23dBm @ 2.3Ghz Smart CardN/A

  • 22Subscriber Unit Self Install (SU-Si)

    8

    Indoor

    Ethernet 10/100 Mbps

    BMAX-CPE-Si-E-(indoor)

    hub / switch

    PC

    PC

    ALVR-VG-1DnV-C

    1

    FunctionLabel NoStatus IndicationStatus LED1

    Indicates the quality of the received signalSIGNAL LEDs2Ethernet port activity LED when blinking - Ethernet activity

    at the Ethernet port-3

    Ethernet port integrity LED when lit - Ethernet physical layer is OK-4

    Reset button removed starting v4.5.1-5DC power jack7.3V DC6

    RJ-45 connector supports 10/100 BASE-T or USB connected to the customer LAN

    ETHERNET/USB Connector7

    Initiating Scanning ModeScan Button8

    8

    2

    1

    7

    6

    3

    4

    5

  • 23Subscriber Unit Self Install (SU-Si)

    Indoor

    Ethernet 10/100 Mbps

    BMAX-CPE-Si-E-(indoor)

    hub / switch

    PC

    PC

    ALVR-VG-1DnV-C

    FunctionStatus LED- CPE is not powered or power failure.Off

    - CPE is connected with a base station.Green- CPE failure.Red- After power-up (if power supply is ok) until start of self test, after passing self-test until network entry is completed, or upon Orange until network entry is completed, or upon restarting the network entry process.- CPE is being set to Factory Defaults (during 6 seconds after pressing the RESET button for more than 5seconds).

    Blinking Orange

    - In case SIGNAL LEDs 5, 6 and 7 are on: Authentication reject by RADIUS server.- In case SIGNAL LEDS 6 and 7 are on: Rejected by Base Station (Duplicate SU Name in database).- In case LED 7 is on: Authentication Timeout, re-authentication failure (connection to RADIUS server lost).

    Blinking Green

  • 24Subscriber Unit Self Install (SU-Si)

    FunctionLED Nr. 5 dB SNR < 10 dBUp to 110 dB SNR < 15 dBUp to 2

    Indoor

    Ethernet 10/100 Mbps

    BMAX-CPE-Si-E-(indoor)

    hub / switch

    PC

    PC

    ALVR-VG-1DnV-C

    10 dB SNR < 15 dBUp to 215 dB SNR < 20 dBUp to 320 dB SNR < 24 dBUp to 4

    SNR 24 and RSSI < -75Up to 5SNR 24 and RSSI -75Up to 6SNR 24 and RSSI -70Up to 7SNR 24 and RSSI -60Up to 8RSSI -20 (saturation)Up to 9

  • 25Subscriber Unit Self Install (SU-Si)

    Indoor

    Ethernet 10/100 Mbps

    BMAX-CPE-Si-E-(indoor)

    hub / switch

    PC

    PC

    ALVR-VG-1DnV-C

    FunctionLabel

    Press for less than 3 seconds:Initiate Best AU selection process without full scanning. It means that the CPE scans only the AUs detected in the last full scan. The LEDs will be blinking scan. The LEDs will be blinking as mentioned above for Best AU operation.

    Press for 3 seconds or more:Initiate full scan, prepare an updated the best AU list and select the best AU. The LEDs will be blinking as mentioned above for full scan operation.

    Scan Button

  • 26Subscriber Unit Self Install (SU-Si)

    The following drawings describes the embedded antennas main beam direction

    External antenna is referred as ANT 0

    The operational antenna is selected from the SI menus

    Indoor

    Ethernet 10/100 Mbps

    BMAX-CPE-Si-E-3.5

    (indoor)hub /

    switch

    PC

    PC

    ALVR-VG-1DnV-C

    ANT 1 ANT 3

    ANT 0

  • 27Subscriber Unit Self Install (SU-Si)

    Identification of Rosedale 2 by SU Type (Valid for Si&PRO-S)

    Identification of USB/Eth model by Interface Type (USB/Eth)

    USB model requires installation of driver that supplied with the unit (Win 98SE,WinME, supplied with the unit (Win 98SE,WinME, Win2K, WinXP, WinXP 64bits)

    USB model has two MAC Addresses: MAC A MAC that the PC extracts from

    the Si as the PCs USB controller has no MAC (e.g, NIC). This MAC can be viewed in the ARP table of the PC

    MAC B The Rosedale MAC used for authentication with the NPU. This MAC is displayed in the SU menu

  • 28Subscriber Unit Self Install (SU-Si)

    FREQUENCY RANGE

    2.3 - 2.7 GHz

    GAIN 9.5 -10.5dBi VSWR 2:1 (max) 3dB AZIMUTH BEAMWIDTH

    70 (typ)BEAMWIDTH3dB Elevation BEAMWIDTH

    20 (typ)

    POLARIZATION Linear VerticalF/B RATIO -20dB (typ)INPUT IMPEDANCE

    50 (ohm)

  • 29SU-Si 3.x Window Antenna

    FREQUENCY RANGE

    3.4 - 3.7 GHz

    GAIN 12dBi VSWR 2:1 (max) 3dB AZIMUTH BEAMWIDTH

    77 (typ)BEAMWIDTH3dB Elevation BEAMWIDTH

    17 (typ)

    POLARIZATION Linear VerticalF/B RATIO -18dB (typ)INPUT IMPEDANCE

    50 (ohm)

  • New BreezeMAX Si Business Models

  • 31Smart Card

    Plug&Play - The customer just plug the Smart Card to the Si and start to work

    The CPE is purchase in a public location

    Smart Cards are burnt by the operator

    Ver. 09-04-15

    burnt by the operator

  • 32Smart Card

    Smart Card Writer/Reader Application User Information Tab

    Enables to enter the user information necessary for proper authentication

    The User Name and Password are editable to the Sales user only. When logged in as Administrator, these parameters are read only

    User Name and Password provided by operatorSales Administrator

    Ver. 09-04-15

    Sales Administrator

  • 33WiMAX Modem Application

    An easy to follow InstallShield Wizard On screen instructions Language Selection User Name and Password supplied by

    operator Choosing location

    Ver. 09-04-15

  • 34WiMAX Modem Application

    Management Status Tab Shows network connection

    status Graphical display Continuous updates of link

    parameters and quality, counters etc.

    User name,

    Ver. 09-04-15

    User name, connection status,

    SW ver 1 2 3

    1

    2

    3

    Connection between PC and WiMAX Modem

    Indication of correct Modem-Base Station definitions

    Connection to an authentication mechanism (radius server/NPU)

  • 35WiMAX Modem Application

    Management Settings Tab Changeable parameters:

    User Info, BS/AU ID, BW, Scanning Freq, Antenna, Rx Atten, Eth port settings.

    Customization option

    Ver. 09-04-15

  • Thank You