Peripheral PumpsT, TPT, TP
Coverage chart n ≈ 2900 rpm
19
ConstructionClose-coupled peripheral pumps (regenerative pumps) withturbine impeller.T, TP: version with pump casing and lantern bracket in cast iron.B-T, B-TP: version with pump casing and lantern bracket in bronze
(the pumps are supplied fully painted).
ApplicationsFor clean liquids without abrasives, without suspended solids,non-explosive, non-aggressive for the pump materials.For increasing network pressure (follow local specifications).For the reduced dimensions, these pumps are very well suitableto be mounted in cooling and air-conditioning machines andequipments, circulation, boiler feed.
Operating conditionsLiquid temperature from -10 °C to +90 °C.Ambient temperature up to 40 °C.Total suction lift up to 7 m.Continuous duty.
Motor2-pole induction motor, 50 Hz (n ≈ 2900 rpm).
T, TP: three-phase 230/400 V ± 10% up to 3 kW;400/690 V ± 10% from 4 to 7,5 kW;
TM, TPM: single-phase 230 V ± 10% with thermal protector.Capacitor inside the terminal box.
Insulation class F.Protection IP 54.Classification scheme IE2 for three-phase motors from 0,75 kWto 5,5 kW, IE3 for 7,5 kW.Constructed in accordance with: EN 60034-1; EN 60034-30.
EN 60335-1, EN 60335-2-41.
Special features on request- Other voltages.- Frequency 60 Hz (as per 60 Hz data sheet).- Protection IP 55.- Special mechanical seal.- Higher or lower liquid or ambient temperatures.- Construction with bearing bracket.
MaterialsComponents T, TP B-T, B-TPPump casing Cast iron BronzeLantern bracket GJL 200 EN 1561 G-Cu Sn 10 EN 1982Casing cover Cast iron Bronze
GJL 200 EN 1561 G-Cu Sn 10 EN 1982Brass P- Cu Zn Pb 40 2 UNI 5705 for T 61-65-70, B-T 61-70
Impeller Brass P- Cu Zn 40 Pb 2 UNI 5705Bronze G-Cu Sn 10 EN 1982 for T 125, TP 132-132R
Shaft Cr-Ni steel AISI 303T 76, Tp 80-100 Cr-Ni-Mo steel
Chrome steel AISI 430 AISI 316T 61-65-70-100-125, Tp 78-132-132R
Mechanical seal Carbon - Ceramic - NBR
0
0
m
Imp. g.p.m.
m /hl/min
ft
0
01 2 3 4 5 6
100
0
40
80
120
160
5 10 15 20
20 40 60 80
100
200
300
400
500H
Q3
72.853
T 61
TP 100
TP 132
TP 78
TP 80
T 100
T 125
TP 132R
T 76
T 70T 65
0 5U.S. g.p.m. 10 15 20 25
www.calpeda-romania.ro 0722.244.944 www.pompe-calpeda.ro 0734.789.888
164
Performance n ≈ 2900 rpm
Dimensions and weights
P2 Rated motor power output.
H Total head in m.B-T, B-TM = Bronze construction.P1 Maximum power input. * Maximum suction lift 2-3 m.
Peripheral PumpsT, TPT, TP
Qm3/h 0,06 0,12 0,24 0,38 0,48 0,6 0,75 1 1,2 1,5 1,89 2,4 3 3,6 4,2 4,8 5,4 6Q
m3/h
l/min 1 2 4 6,3 8 10 12,5 16 20 25 31,5 40 50 60 70 80 90 100B- T 61E 1,9 1,1 B- TM 61E 2,5 0,55 0,33 0,45 38 36 34 31,5 28 24 19 12,5 5B- T 65E 2,8 1,6 B- TM 65E 3,5 0,8 0,45 0,6 44 42 40 37 33 29 24 16 8
B- T 70/A 3,7 2,2 B- TM 70/A 6 1,3 0,75 1 59 57 55 51 48 43 38 30 22 10
T 76E 5,3 3 TM 76E 7,4 1,6 1,1 1,5 70 68 67 65 62 58 53 46 38 26
T 100/A 11,5 6,6 3 4 103 97 89 82 75 68
T 125/A 9,6 4 5,5 125 110 90 75* 60*
B- TP 78/A 2,3 1,3 B- TPM 78/A 2,8 0,6 0,37 0,5 75 70 60 50 42 35 25 15
B- TP 80E 4 2,3 B- TPM 80E 5,8 1,2 0,75 1 90 85 79 73 61 48 34 20
TP 100/A 9,6 5,5 2,2 3 160 157 151 140 129 115 99 82
TP 132R/A 10,9 5,5 7,5 145 135 120 110 95 70
P2
kW HP
1 ~ 230V P1
A kW
3 ~ 230V 400V
A A
TP 132/A 14,3 7,5 10
Hm
165 143* 120*
kg
TIPODN1 DN2
T 125/A –
T 76E –
T 100/A –
G 11/4 G 11/4 32 470 90 75 170 226 152 125 180 140 40 9,5 90 195 12 39,5 -
G 11/4 G 11/4 26 338 80 56 136 208 117 100 155 125 30 9 80 105 10 18,4 -
G 11/4 G 11/4 32 410 90 59 161 226 152 125 180 140 40 9,5 95 121 12 32,5 -
mm
TP 80E B-TP 80E G 3/4 G 3/4 27 332 80 35 135 208 117 100 155 125 30 9 60 104 10 16,4 16,8
TP 100/A – G 3/4 G 3/4 27 387 80 38 142 208 117 100 155 125 30 9 65 113 10 23,2 -
TP 132R/A –TP 132/A – G 11/4 G 11/4 42 485 112 70 202 272 180 140 230 190 50 11,5 100 183 14 53,6
58,5--
ISO 228 a fM HS h2 h1 H BB B AB A AA K l2 w HA T, TP B-TP
DN2
a
w K
4.93.093
H
fM
BBB
AAAAB
HA HS
DN2 DN1
h1
h2
l2
T 61E: kg 6,3B- T 61E: kg 6,5
T 65E: kg 7,3B- T 65E: kg 7,5
DN1 DN2 mm kgTIPO
ISO 228 T B-T
T 70/A B-T 70/ATP 78/A B-TP 78/A
244
G1 ISO 228
24
160
80 8096
108
G1ISO 228 ISO 228
58G1
122100
22
8
65
63
74.93.227 4.93.218
DN2
a
fM
7
90
106
93
22
112
134
10 71
h2
l2
h3
DN2DN1
182
2422
278276
G 1G 1/2
G 1G 1/2
5024
121127
6356
a fM h2 h1 l2
11,28,2
11,68,8
TYPE
TYPE
www.calpeda-romania.ro 0722.244.944 www.pompe-calpeda.ro 0734.789.888
165
Characteristic curves n ≈ 2900 rpm
19
0 0.5 1 1.5 2 2.5
0 2 4 6 8 10U.S. g.p.m.
0 8 12 16 20 24 28 32 36 40
0 0.1 0.2 0.3 0.4 0.5 0.6
0
10
20
30
40
50
0
20
40
60
80
100
120
140
160
H ft
0
0.1
0.2
0.3
0.4
0
0.1
0.2
0.3
0.4
0.5
P H
P
1
2
3
4
5
6
3
8
13
18
NP
SH
ft
0 0.5 1 1.5 2 2.5
0 1 2 3
0 4 8 12U.S. g.p.m.
0 10 20 30 40 50
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
0
10
20
30
40
50
0
20
40
60
80
100
120
140
160
180
H ft
0
0.2
0.4
0.6
0
0.2
0.4
0.6
0.8
P H
P
0
2
4
6
8
0
5
10
15
20
25
NP
SH
ft
0 1 2 3
0 1 2 3 4
0 4 8 12 16U.S. g.p.m.
0 10 20 30 40 50 60
0 0.2 0.4 0.6 0.8 1
0
10
20
30
40
50
60
70
0
100
200
H ft
0
0.2
0.4
0.6
0.8
1.0
0
0.2
0.4
0.6
0.8
1.0
1.2
P H
P
0
1
2
3
4
5
0
5
10
15
NP
SH
ft
0 1 2 3 4
0 1 2 3 4
0 4 6 8 10 12 14 16U.S. g.p.m.
0 10 20 30 40 50 60
0 0.2 0.4 0.6 0.8 1
0
20
40
60
80
0
100
200
H ft
0
0.4
0.8
1.2
1.6
0
1
2
P H
P
0
1
2
3
4
0
5
10
NP
SH
ft
0 1 2 3 4
Ø 60 Ø 65
Ø 71 Ø 76
Q m /h3
l/min
l/s
H m
P k
WN
PS
H m
Q m /h3
Q m /h3
l/min
l/s
H m
P k
WN
PS
H m
Q m /h372.136 72.137
Q m /h3
l/min
l/s
H m
P k
WN
PS
H m
Q m /h3 72.139
Q m /h3
l/min
l/s
H m
P k
WN
PS
H m
Q m /h3 72.138
T 61ET 65E
T 70/A T 76E
Peripheral PumpsT, TPT, TPwww.calpeda-romania.ro 0722.244.944 www.pompe-calpeda.ro 0734.789.888
166
Characteristic curves n ≈ 2900 rpm
0 0.2 0.4 0.6 0.8 1
0 1 1.5 2 2.5 3 3.5 4 4.5 5U.S. g.p.m.
0 4 6 8 10 12 14 16 18 20
0 0.1 0.2 0.3
0
20
40
60
80
100
0
40
80
120
160
200
240
280
320
H ft
0
0.1
0.2
0.3
0.4
0.5
0
0.1
0.2
0.3
0.4
0.5
0.6
P H
P
0
1
2
3
4
5
0
5
10
15
NP
SH
ft
0 0.2 0.4 0.6 0.8 1
1.2
1.2
0 0.5 1 1.5 2
0 2 3 4 5 6 7 8U.S. g.p.m.
0 5 10 15 20 25 30
0 0.1 0.2 0.3 0.4 0.5
20
40
60
80
100
120
100
200
300
380
H ft
0
0.2
0.4
0.6
0.8
1.0
0
0.2
0.4
0.6
0.8
1.0
1.2
P H
P
0
1
2
3
4
5
0
4
8
12
16
NP
SH
ft
0 0.5 1 1.5 2
0 0.5 1 1.5 2 2.5
0 2 4 6 8 10U.S. g.p.m.
0 10 20 30 40
0 0.1 0.2 0.3 0.4 0.5 0.6
60
100
150
200
200
300
400
500
600
H ft
1
2
3
1.5
2.0
2.5
3.0
3.5
4.0
P H
P
0
2
4
6
0
5
10
15
20
NP
SH
ft
0 0.5 1 1.5 2 2.5
0 1 2 3 4 5
0 4 6 8 10 12 14 16 18 20 22U.S. g.p.m.
0 20 30 40 50 60 70 80
0 0.2 0.4 0.6 0.8 1 1.2
60
70
80
90
100
110
120
130
200
300
400
H ft
2
3
4
5
4
6
P H
P
2
3
4
5
6
8
10
12
14
NP
SH
ft
0 1 2 3 4 5
5
3
Ø 100
Ø80Ø 80
Ø 100
Q m /h3
l/min
l/s
H m
P k
WN
PS
H m
Q m /h3
Q m /h3
l/min
l/s
H m
P k
WN
PS
H m
Q m /h372.145 72.141
Q m /h3
l/min
l/s
H m
P k
WN
PS
H m
Q m /h3 72.140
Q m /h3
l/min
l/s
H m
P k
WN
PS
H m
Q m /h3 72.142
TP 78/A TP 80E
TP 100/A T 100/A
Peripheral PumpsT, TPT, TPwww.calpeda-romania.ro 0722.244.944 www.pompe-calpeda.ro 0734.789.888
167
Characteristic curves n ≈ 2900 rpm
19
0 1 2 3 4 5
0 4 8 12 16 20U.S. g.p.m.
0 20 30 40 50 60 70 80
0 0.2 0.4 0.6 0.8 1 1.2
50
100
150
200
200
300
400
500
600
H ft
2
3
4
5
6
7
4
6
8
P H
P
2
4
6
8
10
10
20
30
NP
SH
ft
0 1 2 3 4 5
0 1 2 3 4 5 6 7
0 10 20 30U.S. g.p.m.
0 20 40 60 80 100
0 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8
60
100
200
300
400
200
500
1000
1300
H ft
P H
P
0
2
4
6
8
10
0
10
20
30
NP
SH
ft
0 1 2 3 4 5 6 7
0
10
16
0
4
8
12
16
20
Ø 124
TP 132/A Ø 132
TP 132/A
TP 132R/A Ø 126
TP 132R/A
Q m /h3
l/min
l/s
H m
P k
WN
PS
H m
Q m /h3
Q m /h3
l/min
l/s
H m
P k
WN
PS
H m
Q m /h372.143 72.144
T 125/A TP 132/ATP 132R/A
Peripheral PumpsT, TPT, TPwww.calpeda-romania.ro 0722.244.944 www.pompe-calpeda.ro 0734.789.888
168
Features
RangeThe high number of pumps in the range can meet the widest range of servicesrequired by the user.
FlexibleThe option to choose between cast iron and bronze materias for the hydraulicparts in contact with the pumped liquid allows T-TP series pumps to be selectedfor use with different types of liquids.
ReliableThe bearing and shaft are designed to ensure the reduction of the stress, provi-ding high reliability under all operating conditions.
Optimized hydraulicsThe pump hydraulics are designed to ensure high performance and consistencyof performance.
Peripheral PumpsT, TPT, TPwww.calpeda-romania.ro 0722.244.944 www.pompe-calpeda.ro 0734.789.888