01000 Detailkatalog STEICO · Construction Construction elements – naturally made of timber...
Transcript of 01000 Detailkatalog STEICO · Construction Construction elements – naturally made of timber...
Construction
Construction elements –naturally made of timber
Contens
etICs timber constructionTimber frame constructionCLT wall
etICs masonry wallMasonry wall with timberMasonry wall glued and plugged
Pitched roofBetween rafter insulationAbove rafter insulation
Over 100 construction details with the STEICO building system
steICo Detail catalog
engineered by nature
Dat
e 05
/ 20
17.
Subj
ect
to e
rro
rs a
nd t
echn
ical
cha
nges
. Th
e cu
rren
t ve
rsio
n ap
plie
s.
STEICO Detail catalog - Contents
Basic structure
1. Level ElementAW External wallDA RoofDE Ceiling
2. Level TypWDVS ETICSVHF External cladding systemSD Pitched roofFD Flat roofHB Timber beamMH Solid woodBE Concrete
3. Level ConstructionHRB Timber frame constructionMH CLT wall MWHU Masonry wall with timberMWG Masonry wall glued and pluggedMW Masonry wall
ZSD Between rafter insulationADD Above rafter insulation
nsi Invisible si VisibleBe Concrete
STEICO Detail catalog - Contents
4. Level Area1 DPC2 External wall / System transitions3 Window / Door4 Rollo 5 Raffstore & window blind6 Roof / System transitions7 Ceiling / System transitions
1 Ridge2 Eaves3 Verge4 Rooflight 5 Element joint6 Collar tie connection7 Connections
Wal
lRo
of
STEICO Detail catalog - Contents
External wall (AW)ETICS (WDVS)Timber frame construction (HRB)
DPCAW-WDVS-HRB-1-10 DPC - Level threshold - Continuous render layer,
Variation for pre-assemble elementsPage 12
AW-WDVS-HRB-1-20 DPC - Elevated threshold - Splashback free Page 13AW-WDVS-HRB-1-30 DPC - Level threshold, reduced splashback zone Page 14AW-WDVS-HRB-1-40 DPC - Level threshold, grating (terrace) Page 15AW-WDVS-HRB-1-50 DPC - Basement ceiling in timber construction Page 16AW-WDVS-HRB-1-60 DPC - Wood fibre in splash zone (tanking slurry) Page 17AW-WDVS-HRB-1-70 DPC - lower edge threshold min. 15 cm over terrain
top edge (gravel bed)Page 18
AW-WDVS-HRB-1-80 DPC - Solid wood wall min. 15 cm over terrain top edge (min. 2% fall)
Page 19
External wall / System transitions
AW-WDVS-HRB-2-10External wall - Transitions - Outside corner with STEICO LVL R edge beam
Page 20
AW-WDVS-HRB-2-20 External wall - Transitions - Outside corner STEICOwall edge beam
Page 21
AW-WDVS-HRB-2-30 External wall - Transitions - Inside corner with STEICO LVL R edge beam
Page 22
AW-WDVS-HRB-2-40 External wall - Transitions - Inside corner with STEICOwall edge beam
Page 23
AW-WDVS-HRB-2-50 External wall - Transitions - Internal wall connection Page 24AW-WDVS-HRB-2-60 External wall - Transitions - Building party wall
flash over zonePage 25
AW-WDVS-HRB-2-90 External wall - Transitions - Element joint vertical Page 26AW-WDVS-HRB-2-100 External wall - Transitions - Expansion joint Page 27AW-WDVS-HRB-2-110 External wall - Transitions - Balcony, integrated
balcony in ETICSPage 28
Window / Door AW-WDVS-HRB-3-10 Window - Side connection with reveal board,
horizontal sectionPage 29
AW-WDVS-HRB-3-20 Window - Upper connection with reveal board, vertical section
Page 30
AW-WDVS-HRB-3-30 Window - Bottom connection with reveal board, vertical section
Page 31
AW-WDVS-HRB-3-40 Doors - Vertical section with reveal board - Level threshold Page 32
STEICO Detail catalog - Contents
Roller blindAW-WDVS-HRB-4-10 Roller blind - Window - Horizontal section with reveal board Page 33AW-WDVS-HRB-4-20 Roller blind - Window - Upper connection, vertical section Page 34AW-WDVS-HRB-4-30 Roller blind - Doors - Vertical section with reveal board -
Level thresholdPage 35
Raffstore & window blind
AW-WDVS-HRB-5-10 Raffstore - Window - Horizontal section with reveal boardPage 36
AW-WDVS-HRB-5-20 Raffstore - Window - Upper connection with reveal board, vertical section
Page 37
AW-WDVS-HRB-5-30 Raffstore - Doors - Vertical section with reveal board - Level threshold (balcony)
Page 38
Roof / System transitionsAW-WDVS-HRB-6-10 Roof - Transitions - Eaves, STEICO LVL projecting roof board
(without rafter doubling)Page 39
AW-WDVS-HRB-6-20 Roof - Transitions - Eaves, above rafter insulation, ETICS on blocking panels
Page 40
AW-WDVS-HRB-6-30 Roof - Transitions - Eaves, solid wood rafter, ETICS between the rafter
Page 41
AW-WDVS-HRB-6-40 Roof - Transitions - Eaves, solid wood rafter with blocking panels
Page 42
AW-WDVS-HRB-6-50 Roof - Transitions - Eaves, with end timber (element assembly)
Page 43
AW-WDVS-HRB-6-60 Roof - Transitions - Eaves, STEICO LVL projecting roof board (without rafter doubling)
Page 44
AW-WDVS-HRB-6-70 Roof - Transitions - Verge, visible projecting roof rafter, above rafter insulation
Page 45
AW-WDVS-HRB-6-80 Roof - Transitions - Verge, with end timber (element assembly)
Page 46
AW-WDVS-HRB-6-90 Roof - Transitions - Gable cheek, continuous wall Page 47AW-WDVS-HRB-6-100 Roof - Transitions - Connection to single pitch roof without
rear ventilationPage 48
Ceiling / System transitionsAW-WDVS-HRB-7-10 Ceiling - Transitions - Continuous render layer - Fiber belt Page 49AW-WDVS-HRB-7-20 Ceiling - Transitions - Transition to rear ventilated facade Page 50
STEICO Detail catalog - Contents
External wall (AW)ETICS (WDVS)CLT wall (MH)
DPCAW-WDVS-MH-1-10 DPC - New build - Heated basement - Ground level below top
edge of concrete ceilingPage 52
AW-WDVS-MH-1-20 DPC - CLT wall min. 15 cm over terrain top edge (min. 2% fall) Page 53
AW-WDVS-MH-1-30 DPC - Un-heated basement - Ground level below top edge of concrete ceiling
Page 54
Window / DoorAW-WDVS-MH-3-10 Window - Side connection with reveal board, horizontal
sectionPage 55
AW-WDVS-MH-3-20 Window - Upper connection with reveal board, vertical section
Page 56
AW-WDVS-MH-3-30 Window - Bottom connection with reveal board, vertical section
Page 57
Roof / System transitionsAW-WDVS-MH-6-10 Roof - Transitions - Eaves, above rafter insulation, ETICS on
blocking panelsPage 58
AW-WDVS-MH-6-20 Roof - Transitions - Eaves, solid wood rafter, ETICS between the rafter
Page 59
AW-WDVS-MH-6-30 Roof - Transitions - Eaves, solid wood rafter with blocking panels
Page 60
AW-WDVS-MH-6-40 Roof - Transitions - Eaves, CLT element, ETICS on blocking panels
Page 61
AW-WDVS-MH-6-50 Roof - Transitions - Verge, visible projecting roof rafter Page 62
STEICO Detail catalog - Contents
External wall (AW)ETICS (WDVS)Masonry wall with timber (MWHU)
DPCAW-WDVS-MWHU-1-10 DPC - Level threshold, continuous render layer Page 64AW-WDVS-MWHU-1-20 DPC - Elevated threshold (splashback free) Page 65AW-WDVS-MWHU-1-30 DPC - Level threshold, grating (terrace) Page 66AW-WDVS-MWHU-1-40 DPC - Lower edge threshold min. 15 cm over terrain top edge
(gravel bed) Page 67
External wall / System transitionsAW-WDVS-MWHU-2-10 External wall - Transitions - Outside corner with STEICOwall
edge beam Page 68AW-WDVS-MWHU-2-20 External wall - Transitions - Inside corner with STEICOwall
edge beam Page 69AW-WDVS-MWHU-2-30 External wall - Transitions - Expansion joint Page 70
Window / DoorAW-WDVS-MWHU-3-10 Window - Side connection with reveal board, horizontal
sectionPage 71
AW-WDVS-MWHU-3-20 Window - Bottom connection with reveal board, vertical section
Page 72
Raffstore & window blindAW-WDVS-MWHU-5-10 Raffstore - Window - Upper connection with reveal board,
vertical sectionPage 73
Roof / System transitionsAW-WDVS-MWHU-6-10 Roof - Transitions - Eaves, solid wood rafter with blocking
panelsPage 74
AW-WDVS-MWHU-6-20 Roof - Transitions - Verge, visible projecting roof rafter Page 75
Ceiling / System transitionsAW-WDVS-MWHU-7-10 Ceiling - Transitions - I-Joist joint horizontal Seite 76
STEICO Detail catalog - Contents
External wall (AW)ETICS (WDVS)Masonry wall glued and plugged (MWG)
DPCAW-WDVS-MWG-1-10 DPC - New build - Heated basement - Ground level below top
edge of concrete ceilingPage 78
AW-WDVS-MWG-1-20 DPC - New build - Heated basement - Ground level on top edge of concrete ceiling
Page 79
AW-WDVS-MWG-1-30 DPC - Existing - Un-heated basement - Ground level below top edge of concrete ceiling
Page 80
Window / DoorAW-WDVS-MWG-3-10 Window - New build - Side connection with reveal board,
horizontal sectionPage 81
AW-WDVS-MWG-3-20 Window - New build - Upper connection with reveal board, vertical section
Page 82
AW-WDVS-MWG-3-30 Window - New building - Bottom connection with reveal board, vertical section
Page 83
STEICO Detail catalog - Contents
Roof (DA)Pitched roof (SD)Between rafter insulation (ZSD)
FirstDA-SD-ZSD-1-10 Ridge - Sloped purlin - Element assembly with fixing point Page 85DA-SD-ZSD-1-20 Ridge - Rectangular purlin - Element assembly Page 86DA-SD-ZSD-1-30 Ridge - Side connection with metal sheet Page 87
EavesAW-WDVS-HRB-6-10 Roof - Transitions - Eaves, STEICO LVL projecting roof board
(without rafter doubling)Page 88
AW-WDVS-HRB-6-30 Roof - Transitions - Eaves, solid wood rafter, ETICS between the rafter
Page 89
AW-WDVS-HRB-6-40 Roof - Transitions - Eaves, solid wood rafter with blocking panels
Page 90
AW-WDVS-HRB-6-50 Roof - Transitions - Eaves, with end timber (element assembly)
Page 91
AW-WDVS-MH-6-20 Roof - Transitions - Eaves, solid wood rafter, ETICS between the rafter
Page 92
AW-WDVS-MH-6-30 Roof - Transitions - Eaves, solid wood rafter with blocking panels
Page 93
AW-WDVS-MWHU-6-10 Roof - Transitions - Eaves, solid wood rafter with blocking panels
Page 94
Verge AW-WDVS-HRB-6-60 Roof - Transitions - Eaves, STEICO LVL projecting roof board
(without rafter doubling)Page 95
AW-WDVS-HRB-6-80 Roof - Transitions - Verge, with end timber (element assembly)
Page 96
AW-WDVS-MH-6-50 Roof - Transitions - Verge, visible projecting roof rafter Page 97AW-WDVS-MWHU-6-20 Roof - Transitions - Verge, visible projecting roof rafter Page 98
DFFDA-SD-ZSD-4-10 Rooflight - Trimmer connection with metalwork Page 99DA-SD-ZSD-4-20 Rooflight - Trimmer connection without metalwork Page 100
Element jointDA-SD-ZSD-5-10 Element joint - Roof element joint Page 101
KehlbalkenanschlussDA-SD-ZSD-6-10 Collar tie connection Page 102
ConnectionsAW-WDVS-HRB-6-90 Roof - Transitions - Gable cheek, continuous wall Page 103AW-WDVS-HRB-6-100 Roof - Transitions - Connection to single pitch roof without
rear ventilationPage 104
STEICO Detail catalog - Contents
Roof (DA)Pitched roof (SD)Above rafter insulation (AD)
FirstDA-SD-ADD-1-10 Ridge - Purlin roof truss Page 106
EavesAW-WDVS-MH-6-10 Roof - Transitions - Eaves, above rafter insulation, ETICS on
blocking panelsPage 107
AW-WDVS-MH-6-40 Roof - Transitions - Eaves, CLT element, ETICS on blocking panels
Page 108
AW-WDVS-HRB-6-20 Roof - Transitions - Eaves, above rafter insulation, ETICS on blocking panels
Page 109
Verge AW-WDVS-HRB-6-70 Roof - Transitions - Verge, visible projecting roof rafter,
above rafter insulationPage 110
DFFDA-SD-ADD-4-10 Rooflight Page 111
ConnectionsDA-SD-ADD-7-10 Fixed with dual threaded screws, v-screwing, above rafter
insulationPage 112
DA-SD-ADD-7-20 Fixed with single thread screw, above rafter insulation Page 113DA-SD-ADD-7-30 Rafter doubling with STEICO joist, above rafter insulation Page 114DA-SD-ADD-7-40 Valley - Purlin roof truss Page 115
Legend of hatching Page 116Legend of profile Page 117
Wall construction(from inside to outside)
Nr. Material Thickness in cm1 Plasterboard 1.252 OSB, airtight tape 1.503 STEICOflex with I-Joist 60/240 24.004 STEICOprotect 6.005 Approved plaster system 0.80
11 von 117
0
0
≥ 5
cm
≥ 15
cm
0.292≥ 30 cm
0.10
0
0.30
0
1
2
3
4
5
6
7
8
9
10
11
14 1516
17
> 1
0 cm
1312
Legend:
Sufficient drainage
min
. 30
cm
Wall construction(from inside to outside)- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- Approved plaster system
1 STEICOmulti fill2 Additional mesh tape with sufficient coverage
to ensure surface re-inforcement3 Cement bonded board4 EPS insulation with textured surface5 Sealing in accordance with DIN 18195-4, taken to the inside6 DPC edge profile7 Below DPC render in accordance with render recommendation,
in ground environment with flexible, mineral render sealing8 Gravel bed, grain size min. 16/329 Perimeter insulation10 Building weathering protection, min. 15 cm above ground level11 STEICO LVL Laminated Veneer Lumber12 Swelling mortar13 Bituminous sheeting14 STEICOtherm15 Wet screed16 STEICOsoundstrip17 Airtight tape
Maßstab: 1 : 5.0Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 12-03-2015 Detailnummer: AW-WDVS-HRB-1-10
DPC - Level threshold, continuous render layer, variation for pre-assemble elements
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
12 von 117
1
6
7
83
0.30
9
2
12
9
10
11
13
5
4
0≤ 40 mm(DIN 4108 Bbl. 2)
Legend:
Sufficient drainage
Wall construction(from inside to outside)
Spl
ash
wat
er z
one
min
. 30
cm
- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- Approved plaster system
1 DPC edge profile2 Joint sealing tape3 Trowelled joist4 Below DPC render in accordance
with render recommendation,in ground environment with flexible,mineral render sealing
5 Building weathering protectionmin. 15 cm above ground level
6 Perimeter insulation7 STEICO LVL Laminated Veneer
Lumber8 Swelling mortar9 Bituminous sheeting10 STEICOtherm11 Wet screed12 STEICOsoundstrip13 Airtight tape
Maßstab: 1 : 5.0Änderung: 30-03-2017 Bearbeiter: A. Luz
Datum: 12-03-2015 Detailnummer: AW-WDVS-HRB-1-20
DPC - Elevated threshold - Splashback free
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
13 von 117
0
0
≥ 5
cm
≥ 15
cm
0.292≥ 30 cm0
.100
> 1
0 cm
0.30
0
1
2
3
4
5
6
7
8
9
10
11
12 13
14 1516
17
min
. 30
cm
Sufficient drainage
Legend:Wall construction(from inside to outside)- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- Approved plaster system
1 STEICOmulti fill2 Additional mesh tape with sufficient coverage
to ensure surface re-inforcement3 Cement bonded board4 EPS insulation with textured surface5 Sealing in accordance with DIN 18195-46 DPC edge profile7 Below DPC render in accordance with render recommendation,
in ground environment with flexible, mineral render sealing8 Gravel bed, grain size min. 16/329 Perimeter insulation10 Building weathering protection, min.15 cm above ground level11 STEICO LVL Laminated Veneer Lumber12 Swelling mortar13 Bituminous sheeting14 STEICOtherm15 Wet screed16 STEICOsoundstrip17 Airtight tape
Maßstab: 1 : 5.0Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 12-03-2015 Detailnummer: AW-WDVS-HRB-1-30
DPC - Level threshold, reduced splashback zone
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
14 von 117
0
0
0
≥ 30
cm
≥ 10
cm
≥ 30 cm
1 2
6
4
7
8
3
0.11
4
9
10
11
12
13
14
5
40
≥ 15
cm
0≤ 40 mm(DIN 4108 Bbl. 2)
≥ 15
cm
Legend:
Sufficient drainage
Wall construction(from inside to outside)- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- Approved plaster system
1 DPC edge profile2 Joint sealing tape3 Cement bonded board4 Perimeter insulation5 Sealing in accordance with DIN 18195-46 Grating7 Below DPC render in accordance with render recommendation in
ground enviroment with flexible, mineral render sealing8 Gravel bed, grain size min. 16/32 mm9 Building weathering protection, min. 15 cm above ground level10 Swelling mortar11 STEICO LVL Laminated Veneer Lumber12 Bituminous sheeting13 STEICOsoundstrip14 Airtight tape
Maßstab: 1 : 5.0Änderung: 30-03-2017 Bearbeiter: A. Luz
Datum: 12-03-2015 Detailnummer: AW-WDVS-HRB-1-40
DPC - Level threshold, grating (terrace)
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
15 von 117
1
2
3
6
7
7
8
9 9
9
10
11
12
5
40.30
0
0≤ 40 mm(DIN 4108 Bbl. 2)
Legend:
min
. 30
cm
Sufficient drainage
Wall construction(from inside to outside)
- Floor covering- Dry screed element- STEICOtherm 40 mm- Timber based panel product (OSB), airtight tape - STEICOjoist + STEICOflex- Cement bondedparticle board
- Suspended ceiling
- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- Approved plaster system
1 DPC edge profile2 Joint sealing tape3 Trowelled joist4 Below DPC render in accordance with render
recommendation, in ground enviromentwith flexible, mineral render sealing
5 Sealing in accordance with DIN 18195-46 Perimeter insulation7 Building weathering protection,
min. 15 cm above ground level8 Suspended ceiling9 STEICO LVL Laminated Veneer Lumber10 Timber based panel product (OSB)
and vapour barrier11 STEICOsoundstrip12 Airtight tape
Floor construction(from top to bottom)
Maßstab: 1 : 5.0Änderung: 30-03-2017 Bearbeiter: A. Luz
Datum: 13-03-2015 Detailnummer: AW-WDVS-HRB-1-50
DPC - Basement ceiling in timber construction
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
16 von 117
0.30
0
0≥
15 c
m
0.292≥ 30 cm0.
100
1
2
8
9
10
11
14 1516
17
> 1
0 cm
3
4
5
7
6
1312
Legend:
min
. 30
cm
Sufficient drainage
Wall construction(from inside to outside)- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- Approved plaster system
1 STEICOprotect2 Re-inforced render including mesh with water repellent highly cured,
cementitious tanking membrane3 Cement bonded board4 Sealing in accordance with DIN 18195-4, taken to the inside5 DPC edge profile6 Trowelled joist7 Below DPC render in accordance with render recommendation
in ground enviroment with flexible, mineral render sealing8 Gravel bed, grain size min. 16/329 Perimeter insulation10 Building weathering protection, min. 15 cm above ground level11 STEICO LVL Laminated Veneer Lumber12 Swelling mortar13 Bituminous sheeting14 STEICOtherm15 Wet screed16 STEICOsoundstrip17 Airtight tape
Maßstab: 1 : 5.0Änderung: 30-03-2017 Bearbeiter: A. Luz
Datum: 12-03-2015 Detailnummer: AW-WDVS-HRB-1-60
DPC - Wood fibre in splashback zone (tanking slurry)
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
17 von 117
0.300
0.15
0≥
15 c
m
0.252
2 3
6
10
11
12
131415
16
1
9
8
7
≥ 30 cm
≥ 15 cm
5
4
0≤ 40 mm(DIN 4108 Bbl. 2)
Legend:
Sufficient drainage
Wall construction(from inside to outside)- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- Approved plaster system
1 In splash water zone (up to min. 30 cm over ground level)apply cementitious tanking slurry as moisture protection layerbetween upper and lower render
2 DPC edge profile3 Joint sealing tape4 Trowelled joist5 Below DPC render in accordance with render recommendation
in ground enviroment with flexible, mineral render sealing6 Garden edging7 Gravel bed, grain size min. 16/328 Perimeter insulation9 Building weathering protection, min. 15 cm above ground level10 Swelling mortar11 STEICO LVL Laminated Veneer Lumber12 Bituminous sheeting13 STEICOtherm14 Wet screed15 STEICOsoundstrip16 Airtight tape
Maßstab: 1 : 5.0Änderung: 30-03-2017 Bearbeiter: A. Luz
Datum: 12-03-2015 Detailnummer: AW-WDVS-HRB-1-70
DPC - Lower edge threshold min. 15 cm over terrain top edge (gravel bed)
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
18 von 117
0.15
1
2 3
7
8
9
10
11
12
131415
16
1
4
6
5
0≤ 40 mm(DIN 4108 Bbl. 2)
≥ 15
cm
Legend:
Fall min. 2%
Wall construction(from inside to outside)- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- Approved plaster system
1 In splash water zone (up to min. 30 cm over ground level)apply cementitious tanking slurry as moisture protection layerupper and lower render
2 DPC edge profile3 Joint sealing tape4 Trowelled joist5 Below DPC render in accordance with render recommendation,
in ground enviroment with flexible, mineral render sealing6 Terrain top edge7 Finished floor covering (= water-carrying layer) min. 2% fall8 Perimeter insulation9 Building weathering protection, min. 15 cm above ground level10 Swelling mortar11 STEICO LVL Laminated Veneer Lumber12 Bituminous sheeting13 STEICOtherm14 Wet screed15 STEICOsoundstrip16 Airtight tape
Maßstab: 1 : 5.0Änderung: 30-03-2017 Bearbeiter: A. Luz
Datum: 12-03-2015 Detailnummer: AW-WDVS-HRB-1-80
DPC - Lower edge threshold min. 15 cm over terrain top edge (min. 2% fall)
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
19 von 117
123
4
5
6
Legend:1 Mesh corner angle2 STEICOmulti fill glueing optional3 Square cut joint4 STEICO LVL R Laminated Veneer Lumber5 Pre designed fixing point. Site filled with STEICOflex.
Opening should be made airtight with vapour control layer6 STEICOmulti tape
Wall construction(from inside to outside)- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- Approved plaster system
Maßstab: 1 : 5.0Änderung: 28-03-2017 Bearbeiter: A. Luz
Datum: 20-03-2015 Detailnummer: AW-WDVS-HRB-2-10
External wall - Transitions - Outside corner with STEICO LVL R edge beam
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
20 von 117
123
4
5
6
Legend:Wall construction(from inside to outside)- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- Approved plaster system
1 Mesh corner angle2 STEICOmulti fill glueing optional3 Square cut joint4 STEICOwall I-Joist5 Pre designed fixing point. Site filled with STEICOflex.
Opening should be made airtight with vapour control layer6 STEICOmulti tape
Maßstab: 1 : 5.0Änderung: 28-03-2017 Bearbeiter: A. Luz
Datum: 20-03-2015 Detailnummer: AW-WDVS-HRB-2-20
External wall - Transitions - Outside corner with STEICOwall edge beam
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
21 von 117
1 2
3
45
Detail A
Detail A, M 1:2,5
Legend:1 STEICOmulti tape2 Corner angle3 STEICO LVL R Laminated Veneer Lumber4 STEICOflex5 Expansion joint profile
Wall construction(from inside to outside)- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- Approved plaster system
Maßstab: 1 : 5.0Änderung: 22-03-2017 Bearbeiter: A. Luz
Datum: 20-03-2015 Detailnummer: AW-WDVS-HRB-2-30
External wall -Transitions - Inside corner with STEICO LVL R edge beam
4
5
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
22 von 117
1 2
45
Detail A
Detail A, M 1:2,5
3
Legend:1 STEICOmulti tape2 Corner angle3 STEICOwall I-Joist4 STEICOflex5 Expansion joint profile
Wall construction(from inside to outside)- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- Approved plaster system
Maßstab: 1 : 5.0Änderung: 22-03-2017 Bearbeiter: A. Luz
Datum: 20-03-2015 Detailnummer: AW-WDVS-HRB-2-40
External wall - Transitions - Inside corner with STEICOwall edge beam
4
5
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
23 von 117
2
3
Detail A
4
4
1
Detail A after mounting, M 1:5,0
Legend:External wall construction(from inside to outside- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- Approved plaster system
Internal wall construction(from inside to outside)- Plasterboard- OSB- STEICOflexSolid timber orSTEICO LVL R
- OSB- Plasterboard
1 Construction joint 5mmin timber based panel product
2 STEICOmulti tape3 Mounting timber4 Paper joint re-inforcement band filled
Maßstab: 1 : 5.0Änderung: 28-03-2017 Bearbeiter: A. Luz
Datum: 23-03-2015 Detailnummer: AW-WDVS-HRB-2-50
External wall - Transitions - Internal wall connection
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
24 von 117
1
2
3
4
4
5
6
3
- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect (min. 60 mm)- Approved plaster system(mineral)
Legend:External wall construction(from inside to outside)
1 Non-combustible insulating material T > 1000 °C2 STEICOprotect joint profile, 10-20 mm flexible3 Metal angles in accordance with
wood fire protection manual4 STEICO LVL Laminated Veneer Lumber5 STEICOmulti tape6 Paper joint re-inforcement band filled
- Plasterboard- OSB, airtight tape- STEICOflexSTEICO LVLLaminated Veneer Lumber
- OSB - 12 mm- Plasterboard 6 KF 2 x 15 mm- Non-combustibleinsulating materialT > 1000 °C
Building party wall construction(from inside to outside)
Maßstab: 1 : 5.0Änderung: 28-03-2017 Bearbeiter: A. Luz
Datum: 23-03-2015 Detailnummer: AW-WDVS-HRB-2-60
External wall - Transitions - Building party wall, flash over zone
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
25 von 117
1
Detail A
3 4 5
2
Mounting process, M 1:7.5 Detail A after mounting, M 1:2.5
External wall construction(from inside to outside) Legend:- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- Approved plaster system
1 STEICOmulti fill glueing2 Web insulation3 Connection plate of timber based panel product4 STEICOmulti tape5 Plasterboard mounting cover
Maßstab: 1 : 5.0Änderung: 28-03-2017 Bearbeiter: A. Luz
Datum: 23-03-2015 Detailnummer: AW-WDVS-HRB-2-90
External wall - Transitions - Element joint vertical
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
26 von 117
1
2
3
External wall construction(from inside to outside) Legend:
- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- Approved plaster system
1 STEICOprotect joint profile10-20 mm flexible
2 Web insulation3 STEICOmulti tape
Maßstab: 1 : 2.5Änderung: 28-03-2017 Bearbeiter: A. Luz
Datum: 23-03-2015 Detailnummer: AW-WDVS-HRB-2-100
External wall - Transitions - Expansion joint
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
27 von 117
1
1 2
3
5
7
89 10
11
13
12
0.05
0
15
6
≥ 5
cm
14
16
4Fall min. 2%
Wall construction(from inside to outside)
Legend:
- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- Approved plaster system
- Floor covering- Dry screed 25 mm- STEICOtherm 40 mm- Timber based panel product (OSB)- STEICOjoist+ STEICOflex 120 mm
- Trickle protection- Batten- Plasterboard
1 Joint sealing tape2 Metal sheet upstand3 Drainage channel cover, height adjustable4 Protective plate in front of seal5 Coated aluminium dovetail connector6 Glulam rimboard7 STEICOtherm as core insulation8 Anchorage above angle connector9 Drip edge10 Joint sealing tape11 Trowelled joist12 Vapour barrier in connection areas13 STEICO LVL Laminated Veneer Lumber14 Airtight window installation (DIN 4108-7)15 STEICOflex 240 mm in connection area16 Insulation wedge
- Wooden flooring 30 mm- Support batten 40 mm- Drainage mat- EPDM- Sealing membrane- Timber based panel product
visible- Joist location
Balcony construction(from top to bottom)
Ceiling construction(from top to bottom)
Maßstab: 1 : 5.0Änderung: 28-03-2017 Bearbeiter: A. Luz
Datum: 02-04-2015 Detailnummer: AW-WDVS-HRB-2-110
External wall - Transitions - Balcony, integrated balcony in ETICS
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
28 von 117
1
0.022ca. 18-22 mm
1
0
2
3
4
5
6
7
89
10
Recommendation30-50 mm
Wall construction(from inside to outside) Legend:- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- Approved plaster system
1 STEICOmulti tape2 STEICObase3 Seprerating strips4 Clean finish render stop bead5 Joint sealing tape6 STEICOprotect H reveal board 20 mm7 End profile for ETICS suitable8 Surface mesh9 Aluminium window sill10 Window sill inside
Maßstab: 1 : 2.5
Datum: 06-03-2015
Änderung: 22-03-2017 Bearbeiter: A. Luz
Detailnummer: AW-WDVS-HRB-3-10
Window - Side connection with reveal board, horizontal section
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
29 von 117
1
1
2 3 4
5 6 7
8
Wall construction(from inside to outside) Legend:- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- Approved plaster system
1 STEICOmulti tape2 STEICObase3 Seprerating strips4 Clean finish render stop bead5 Joint sealing tape6 STEICOprotect H reveal board 20 mm7 Drip edge profile8 Surface mesh
Maßstab: 1 : 2.5Änderung: 22-03-2017 Bearbeiter: A. Luz
Datum: 11-03-2015 Detailnummer: AW-WDVS-HRB-3-20
Window - Upper connection with reveal board, vertical section
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
30 von 117
1
2
1
4
788
8
5 6
9
1
3
0.046
10
Wall construction(from inside to outside) Legend:- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- Approved plaster system
1 STEICOmulti tape2 Window sill inside3 Web insulation4 STEICOmulti UDB5 STEICOfix wood fibre insulation fillet6 Bonded membrane on insulation fillet7 Aluminium window sill8 Joint sealing tape9 Parapet profile10 STEICOmulti fill glueing
Recommendation30-50 mm
Maßstab: 1 : 2.5Änderung: 29-03-2017 Bearbeiter: A. Luz
Datum: 12-03-2015 Detailnummer: AW-WDVS-HRB-3-30
Window - Bottom connection with reveal board, vertical section
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
31 von 117
1
2 3 4 5
6
8
9
10
13
12
11
10
1
7
1
1514
0
50.
061
≥ 5
cm
Wall construction(from inside to outside)
Legend:
Recommendation30-50 mm
Note:
- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- Approved plaster system
Juliet balcony
- Floor covering- Dry screed 25 mm- STEICOtherm 40 mm- Timber based panel product (OSB)- STEICOjoist+ STEICOflex 120 mm
- Trickle protection- Batten- Plasterboard
To position 11:The so-called "fiber" belt is inserted exact on site.The board joint should be sanded after installation.
Ceiling construction(from top to bottom)
1 Joint sealing tape2 Aluminium window sill3 STEICOfix wood fibre insulation fillet4 Bonded membrane on insulation fillet5 STEICOmulti tape
Airtight window installation (DIN 4108-7)6 STEICOmulti UDB7 Parapet profile8 STEICOtherm as edge side
insolation9 Vapour barrier in connection areas10 STEICO LVL Laminated Veneer Lumber11 STEICOprotect fitting piece, adjusted on site12 Additional mesh tape with sufficient coverage
to ensure surface re-inforcement13 STEICOmulti fill14 Tension and compression resistant connection
(to structural requirements)15 STEICOflex 240 mm in connection area
Maßstab: 1 : 5.0Änderung: 29-03-2017 Bearbeiter: A. Luz
Datum: 02-04-2015 Detailnummer: AW-WDVS-HRB-3-40
Doors - Vertical section with reveal board - Level threshold
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
32 von 117
3
1
4
2
0.027ca. 18-22 mm
7
8
11
13
6 5
12
0
10
9Recommendation30-50 mm
Wall construction(from inside to outside) Legend:- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- Approved plaster system
1 Airtight window installation (DIN 4108-7)2 Corner angle3 STEICObase4 Seprerating strips5 Clean finish render stop bead6 Joint sealing tape7 STEICOprotect H reveal board8 End profile for ETICS suitable9 Surface mesh10 Aluminium window sill11 Window sill inside12 Roller blind guide rail13 Reinforced rollerblind
Maßstab: 1 : 2.5
Datum: 06-03-2015
Änderung: 29-03-2017 Bearbeiter: A. Luz
Detailnummer: AW-WDVS-HRB-4-10
Roller blind - Window - Horizontal section with reveal board
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
33 von 117
1
2
3
4 5 6
8 9
7
10
Wall construction(from inside to outside)
Legend:
- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- Approved plaster system
1 Airtight window installation (DIN 4108-7)2 Corner angle3 STEICObase4 Seprerating strips5 Joint sealing tape6 Access panel7 Guide rail8 Galvanised steel, powder coated9 DPC level mounting profile10 STEICOmulti fill glueing
Maßstab: 1 : 2.5Änderung: 22-03-2017 Bearbeiter: A. Luz
Datum: 12-03-2015 Detailnummer: AW-WDVS-HRB-4-20
Roller blind - Window - Upper connection, vertical section
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
34 von 117
0.15
0
1
2
3
4
6
54 4
0
0.14
9
0.30
0≥
30 c
m
≥ 15
cm
7 8
910
11 12
13 14 15
16≥
15 c
m
Wall construction(from inside to outside) Legend:
Fall min. 2%
Recommendation30-50 mm
Sufficient drainage
- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- Approved plaster system
1 Roller blind guide rail2 DPC edge profile, change of material
see Detail AW-WDVS-HRB-1-403 Grating4 Joint sealing tape5 Sealing in accordance with DIN 18195
Building weathering protection6 Insulation fillet7 Aluminium window sill8 Render stop profile9 Below DPC render in accordance with render recommendation
in ground enviroment with flexible, mineral render sealing10 Gravel bed, grain size min. 16/32 mm11 Perimeter insulation12 Building weathering protection, min. 15 cm above ground level13 Cement bounded board14 Swelling mortar15 STEICOsoundstrip16 Airtight window installation (DIN 4108-7)
Maßstab: 1 : 5.0Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 12-03-2015 Detailnummer: AW-WDVS-HRB-4-30
Roller blind - Doors - Vertical section with reveal board - Level threshold
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
35 von 117
1
4
2
0.027ca. 18-22 mm
7
8
11
3
6 5
12
13
0
10
9Recommendation30-50 mm
Wall construction(from inside to outside) Legend:- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- Approved plaster system
1 Airtight window installation (DIN 4108-7)2 Corner angle3 STEICObase4 Seprerating strips5 Clean finish render stop bead6 Joint sealing tape7 STEICOprotect H reveal board8 End profile for ETICS suitable9 Surface mesh10 Aluminium window sill11 Window sill inside12 Raffstore- guide rail13 Raffstore- lamella
Maßstab: 1 : 2.5
Datum: 06-03-2015
Änderung: 04-04-2017 Bearbeiter: A. Luz
Detailnummer: AW-WDVS-HRB-5-10
Raffstore - Window - Horizontal section with reveal board
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
36 von 117
1
2
3 4
5
8
9
7 7
10
3
6
11
Wall construction(from inside to outside) Legend:- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- Approved plaster system
1 Airtight window installation (DIN 4108-7)2 Corner angle3 STEICObase4 Seprerating strips5 Joint sealing tape6 Raffstore7 STEICOprotect H reveal board8 DPC edge profile9 STEICOmulti fill glueing10 Surface mesh11 Raffstore-guide rail
Maßstab: 1 : 2.5Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 12-03-2015 Detailnummer: AW-WDVS-HRB-5-20
Raffstore - Window - Upper connection with reveal board, vertical section
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
37 von 117
1
1 2
5
7
89 10
11
13
12
0.05
0
15
6
≥ 5
cm
14
16
3 4
17
Fall min. 2%
Wall construction(from inside to outside)
Legend:
- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- Approved plaster system
1 Joint sealing tape2 Metal sheet upstand3 Drainage channel cover, height adjustable4 Protective plate in front of seal5 Coated aluminium dovetail connector6 Glulam rimboard7 STEICOtherm as core insulation8 Anchorage above angle connector9 Drip edge10 Joint sealing tape11 Trowelled joist12 Vapour barrier in connection areas13 STEICO LVL Laminated Veneer Lumber14 Airtight window installation (DIN 4108-7)15 STEICOflex 240 mm in connection area16 Insulation wedge17 Raffstore- guide rail
Balcony construction(from top to bottom)
Ceiling construction(from top to bottom)- Floor covering- Dry screed 25 mm- STEICOtherm 40 mm- Timber based panel product (OSB)- STEICOjoist+ STEICOflex 120 mm
- Trickle protection- Batten- Plasterboard
- Wooden flooring 30 mm- Support batten 40 mm- Drainage mat- EPDM membrane- Timber based panel productvisible
- Joist location
Maßstab: 1 : 5.0Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 02-04-2015 Detailnummer: AW-WDVS-HRB-5-30
Raffstore - Doors - Vertical section with reveal board - Level threshold (balcony)
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
38 von 117
1
2
3
4 5
6
7
8
9
10
1112
External wall construction(from inside to outside)
Roof construction(from inside to outside) Legend:
- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- Approved plaster system
- Plasterboard- Batten- Vapour barrier- STEICOzellSTEICOjoist
- STEICOuniversal- Counter batten- Support batten- Roof covering
1 STEICOmulti UDB (only in eaves zone)2 STEICOuniversal 22 mm, assembled on site3 STEICO LVL-X 39 mm with surface treatment,
on site fitted projecting roof board4 Joint sealing tape5 Trowelled joist6 STEICOprotect H, adjusted on site7 STEICOflex in assembled frame8 STEICO LVL X sheat cleat9 I-Joist as studs10 STEICOzell in insulation zone11 STEICOuniversal 60 mm, factory assembled12 STEICOmulti tape + STEICOmulti primer
Maßstab: 1 : 7.5Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 02-04-2015 Detailnummer: AW-WDVS-HRB-6-10
Roof - Transitions - Eaves, STEICO LVL projecting roof board (without rafter doubling)
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
39 von 117
1
2
4
5
9
610
3
7 8
11
External wall construction(from inside to outside) Legend:- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- Approved plaster system
1 Insect screen2 Drip plate3 Blocking panel (notched into rafter)4 Joint sealing tape5 Trowelled joist6 STEICO LVL Laminated Veneer Lumber7 Angled timber for connecting the blocking panel8 Blocking panel on room side9 Shadow joint10 STEICOmulti tape11 Tilting fillet
Roof construction(from inside to outside)- Visible rafter- Visible sheathing- Vapour barrier- STEICOtherm- STEICOuniversal(below roof covering)
- Counter batten- Support batten- Roof covering
Maßstab: 1 : 7.5Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 02-04-2015 Detailnummer: AW-WDVS-HRB-6-20
Roof - Transitions - Eaves, above rafter insulation, ETICS on blocking panels
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
40 von 117
12 6
7
34
5
External wall construction(from inside to outside)
Roof construction(from inside to outside) Legend:
- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- Approved plaster system
1 Insect screen2 Drip plate3 Blocking between the rafters4 Joint sealing tape5 Trowelled joist6 STEICO LVL Laminated Veneer Lumber7 Paper joint re-inforcement band filled
- Plasterboard- Batten- Vapour barrier- STEICOflexSolid wood rafter (Glulam)
- STEICOuniversal- Counter batten- Support batten- Roof covering
Maßstab: 1 : 7.5Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 02-04-2015 Detailnummer: AW-WDVS-HRB-6-30
Roof - Transitions - Eaves, solid wood rafter, ETICS between the rafter
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
41 von 117
12
5
6
7
4
3
Legend:External wall construction(from inside to outside)
Roof construction(from inside to outside)
- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- Approved plaster system
1 Insect screen2 Drip plate3 Blocking panels (notched into rafter)4 Joint sealing tape5 Trowelled joist6 STEICO LVL Laminated Veneer Lumber7 Paper joint re-inforcement band fille
- Plasterboard- Batten- Vapour barrier- STEICOflexSolid wood rafter (Glulam)
- STEICOuniversal- Counter batten- Support batten- Roof covering
Maßstab: 1 : 7.5Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 02-04-2015 Detailnummer: AW-WDVS-HRB-6-40
Roof - Transitions - Eaves, solid wood rafter with blocking panels
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
42 von 117
12
3
7
8
6
4
5
External wall construction(from inside to outside)
Roof construction(from inside to outside) Legend:
- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- Approved plaster system
1 Insect screen2 Drip plate3 Blocking panels (notched into rafter)4 Joint sealing tape5 Trowelled joist6 End timber7 STEICO LVL Laminated Veneer Lumber8 Paper joint re-inforcement band fille
- Plasterboard- Batten- Vapour barrier- STEICOflexSolid wood rafter (Glulam)
- STEICOuniversal- Counter batten- Support batten- Roof covering
Maßstab: 1 : 7.5Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 02-04-2015 Detailnummer: AW-WDVS-HRB-6-50
Roof - Transitions - Eaves, with end timber (element assembly)
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
43 von 117
2
3
6
7
8
9
Detail A, M 1:2,5
10
15
4Detail A
External wall construction(from inside to outside)
Roof construction(from inside to outside) Legend:
- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- Approved plaster system
- Plasterboard- Batten- Vapour barrier- STEICOzellSTEICOjoist
- STEICOuniversal- Counter batten- Support batten- Roof covering
1 STEICOmulti UDB (only in verge area )2 STEICOuniversal 22 mm3 STEICO LVL-X 39 mm with surface treatment4 STEICOmulti tape + STEICOmulti primer5 STEICOuniversal 60 mm on the roof surface6 Web insulation7 Compressable insulation at connection8 Mounting cover9 Joint sealing tape10 Trowelled joist
Maßstab: 1 : 7.5Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 02-04-2015 Detailnummer: AW-WDVS-HRB-6-60
Roof - Transitions - Eaves, STEICO LVL projecting roof board (without rafter doubling)
54
2
1
3
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
44 von 117
1
23
4
5
6
7
8
9
10
External wall construction(from inside to outside)
Roof construction(from inside to outside) Legend:
- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- Approved plaster system
- Visible rafter- Visible sheathing- Vapour barrier- STEICOtherm- STEICOuniversal(below roof covering)
- Counter batten- Support batten- Roof covering
1 Visible verge sheathing2 Visible projecting roof rafter3 End of insulation leyer, windproofness4 Joint sealing tape5 Trowelled joist6 Purlin doubling7 Purlin8 STEICOmulti tape9 Visible rafter10 Shadow joint
Maßstab: 1 : 7.5Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 02-04-2015 Detailnummer: AW-WDVS-HRB-6-70
Roof - Transitions - Verge, visible projecting roof rafter, above rafter insulation
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
45 von 117
5
2
1
4
8
9
67
3
External wall construction(from inside to outside) Legend:- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- Approved plaster system
Roof construction(from inside to outside)
1 STEICOmulti UDB (only in verge area)2 Visible soffit board3 End timber4 Joint sealing tape5 Trowelled joist6 STEICO LVL Laminated Veneer Lumber7 Solid wood rafter or optional STEICOjoist8 STEICOmulti tape + STEICOmulti primer9 STEICOmulti tape
- Plasterboard- Batten- Vapour barrier- STEICOflexSolid wood rafter (Glulam)
- STEICOuniversal- Counter batten- Support batten- Roof covering
Maßstab: 1 : 7.5Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 02-04-2015 Detailnummer: AW-WDVS-HRB-6-80
Roof - Transitions - Verge, with end timber (element assembly)
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
46 von 117
1
2
3
0.18
5
Detail A
Detail A, M 1:1
7
min
. 15
cm
Roof construction(from inside to outside) Legend:
- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- Approved plaster system
- Plasterboard- Batten- Vapour barrier- STEICOflexSTEICOjoist
- STEICOuniversal- Counter batten- Support batten- Roof covering
1 Foam wedge2 Taping, roofing felt in connection area3 Metal sheet as gutter4 Screw plug5 Re-inforced render including mesh
with water repellent highly cured,cementitious tanking membrane
6 Metal connection profile7 Corner angle
Wall construction (Gable)(from inside to outside)
Maßstab: 1 : 5.0Änderung: 22-03-2017 Bearbeiter: A. Luz
Datum: 23-03-2015 Detailnummer: AW-WDVS-HRB-6-90
Roof - Transitions - Gable cheek, continuous wall
45
6
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
47 von 117
1
2
3
45
6
7
8
9
0.16
2
10
min
. 15
cm
Wall construction(from inside to outside)
Roof construction(from inside to outside) Legend:
- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- Approved plaster system
- Plasterboard- Batten- Vapour barrier- STEICOflexSTEICOjoist
- STEICOuniversal- Counter batten- Support batten- Roof covering
1 Re-inforced render including meshwith water repellent highly cured,cementitious tanking membrane
2 Metal connection profile3 Screw plug4 Wall connection tape
metal sheet upstand with lapped lead5 STEICO LVL Laminated Veneer Lumber6 Tension strap (14° - 45°)7 Vented tile8 Air gap ca. 5 mm9 Roofing felt in connection area,
taped with STEICOmulti tape10 Glulam beam
Maßstab: 1 : 5.0Änderung: 30-03-2017 Bearbeiter: A. Luz
Datum: 23-03-2015 Detailnummer: AW-WDVS-HRB-6-100
Roof - Transitions - Connection to single pitch roof without rear ventilation
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
48 von 117
1
2
3
4
5
96
7
86
Wall construction(from inside to outside)
Legend:
- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- Approved plaster system
- Floor covering- Dry screed 25 mm- STEICOtherm 40 mm- timber based panel product (OSB)- STEICOjoist + STEICOflex- Trickle protection- Batten- Plasterboard
Note:
Ceiling construction(from top to bottom)
To position 2:The so-called "fiber belt" is inserted exact on site.The board joint should be sanded after installation.
1 STEICOmulti fill2 STEICOprotect fitting piece, adjusted on site3 STEICOtherm as edge side insulation4 Additional mesh tape with sufficient coverage
to ensure surface re-inforcement5 Vapour barrier in connection areas6 STEICO LVL Laminated Veneer Lumber7 Tension and compression resistant connection
(to structural requirements)8 Taping, airtight connection9 STEICOflex 120 mm
Maßstab: 1 : 5.0Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 02-04-2015 Detailnummer: AW-WDVS-HRB-7-10
Ceiling - Transitions - Continuous render layer - Fiber belt
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
49 von 117
6
6
12
3
45
7
9
10
8
Legend:Wall construction(from inside to outside)
- Floor covering- Dry screed 25 mm- STEICOtherm 40 mm- Timber based panel product (OSB)- STEICOjoist + STEICOflex- Trickle protection- Batten- Plasterboard
Ceiling construction(from top to bottom)
1 Insect screen2 Drip plate3 Joint sealing tape4 Trowelled joist5 STEICOtherm as edge side insulation6 STEICO LVL Laminated Veneer Lumber7 Vapour barrier in connection areas8 Tension and compression resistant connection
(to structural requirements)9 STEICOmulti tape10 STEICOflex 120 mm
- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- T+G - sheathing vertical +Support batten + Counter battenBasement:Approved plaster system
Maßstab: 1 : 5.0Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 02-04-2015 Detailnummer: AW-WDVS-HRB-7-20
Ceiling - Transitions - Transition to rear ventilated facade
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
50 von 117
Wall construction(from inside to outside)
Nr. Material Thickness in cm1 Plasterboard 1.252 CLT wall 8.003 STEICOprotect, fixed with plate washers 16.004 Approved plaster system 0.80
51 von 117
0.308
1 2
3
4
5
60.05
0
7
8
9
10
13
14
15
≥ 30 cm
≥ 5
cm
0
0
0.30
9
≤ 40 mm(DIN 4108 Bbl. 2)
11 12
16
Wall construction(from inside to outside)
Legend:
Sufficient drainage
Spl
ash
wat
er z
one
min
. 30
cm
1 DPC edge profile2 Joint sealing tape3 Trowelled joist4 Below DPC render in accordance with render recommendation
in ground enviroment with flexible, mineral render sealing5 Perimeter insulation6 Flexible, mineral render sealing7 Gravel bed, grain size min. 16/328 Protective layer, e.g. dimpled drainage layer9 Mortar resin suitable for weathering protection10 Building weathering protection in accordance with DIN 18195
min. 15 cm above ground level11 Swelling mortar/ mortar bed12 Bituminous sheeting13 STEICOtherm14 Wet screed15 STEICOsoundstrip16 Airtight tape
min. 50 mm taken onto the insulation board
- Plasterboard- CLT wall,in connection area airtight tape
- STEICOprotect, fixed withplate washers
- Approved plaster system
Maßstab: 1 : 5.0Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 12-03-2015 Detailnummer: AW-WDVS-MH-1-10
DPC - New build - Heated basement - Ground level below top edge of concrete ceiling
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
52 von 117
0.15
1≥
15 c
m
0≤ 40 mm(DIN 4108 Bbl. 2)
1
2 3
4
5 6
8
9
10
11
12 13
14
1517
160
0.05
0≥
5 c
m
7
Fall min. 2%
Legend:Wall construction(from inside to outside)
1 In splash water zone (up to min. 30 cm over ground level)apply cementitious tanking slurry as moisture protection layerbetween upper and lower render
2 DPC edge profile3 Joint sealing tape4 Trowelled joist5 Below DPC render in accordance with render recommendation
in ground enviroment with flexible, mineral render sealing6 Flexible, mineral render sealing7 Finished floor covering (= water-carrying layer) min. 2% fall8 Protective layer, e.g. dimpled drainage layer9 Perimeter insulation10 Mortar resin suitable for weathering protection11 Building weathering protection in accordance with DIN 18195
min. 15 cm above ground level12 Swelling mortar/ mortar bed13 Bituminous sheeting14 STEICOtherm15 Wet screed16 STEICOsoundstrip17 Airtight tape
min. 50 mm taken onto the insulation board
Ground level
- Plasterboard- CLT wall,in connection area airtight tape
- STEICOprotect, fixed withplate washers
- Approved plaster system
Maßstab: 1 : 5.0Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 12-03-2015 Detailnummer: AW-WDVS-MH-1-20
DPC - CLT wall min. 15 cm over terrain top edge (min. 2% fall)
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
53 von 117
0.308
1 2
3
4
5
60.05
0
7
8
≥ 5
cm
0.30
9
0
0.50
0
≥ 30 cm
≥ 50
0 m
m (
DIN
410
8 B
bl. 2
) ≤ 40 mm(DIN 4108 Bbl. 2)
0
9
10
11 12
131415
16
17
Wall construction(from inside to outside)
Legend:
Sufficient drainage
Spl
ash
wa
ter
zone
min
. 30
cm
1 DPC edge profile2 Joint sealing tape3 Trowelled joist4 Below DPC render in accordance with render recommendation
in ground enviroment with flexible, mineral render sealing5 Perimeter insulation6 Flexible, mineral render sealing7 Gravel bed, grain size min. 16/328 Protective layer, e.g. dimpled drainage layer9 Building weathering protection in accordance with DIN 18195
min. 15 cm above ground level10 Mortar resin suitable for weathering protection11 Swelling mortar/ mortar bed12 Bituminous sheeting13 STEICOtherm14 Wet screed15 STEICOsoundstrip16 Airtight tape17 Basement ceiling insulation in accordance with requirements
min. 50 mm taken onto the insulation board
- Plasterboard- CLT wall,in connection area airtight tape
- STEICOprotect, fixed withplate washers
- Approved plaster system
Maßstab: 1 : 5.0Änderung: 07-04-2017 Bearbeiter: A. Luz
Datum: 12-03-2015 Detailnummer: AW-WDVS-MH-1-30
DPC - Un-heated basement - Ground level below top edge of concrete ceiling
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
54 von 117
0.027ca. 18-22 mm
3
2
4
6
5
7
8
9
11 10
12
13
01
Wall construction(from inside to outside) Legend:
Recommendation 30-50 mm
- Plasterboard- CLT wall,in connection area airtight tape
- STEICOprotect, fixed withplate washers
- Approved plaster system
1 Window sill inside2 STEICObase3 Airtight window installation (DIN 4108-7)4 Seprerating strips5 Clean finish render stop bead6 Joint sealing tape7 STEICOprotect H reveal board8 Mesh corner angle9 End profile for ETICS suitable10 STEICOmulti fill11 Surface mesh12 Mounted frame for window connection,
also possible with i-joist13 Aluminium window sill
Maßstab: 1 : 2.5
Datum: 06-03-2015
Änderung: 04-04-2017 Bearbeiter: A. Luz
Detailnummer: AW-WDVS-MH-3-10
Window - Side connection with reveal board, horizontal section
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
55 von 117
1
23
4
5 6 7 8
10
9
11
Legend:Wall construction(from inside to outside)- Plasterboard- CLT wall,in connection area airtight tape
- STEICOprotect, fixed withplate washers
- Approved plaster system
1 Corner angle2 STEICObase3 Seprerating strips4 Airtight window installation (DIN 4108-7)5 Clean finish render stop bead6 Joint sealing tape7 STEICOprotect H reveal board8 Drip edge profile9 STEICOmulti fill10 Surface mesh11 Mounted frame for window connection,
also possible with i-joist
Maßstab: 1 : 2.5Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 11-03-2015 Detailnummer: AW-WDVS-MH-3-20
Window - Upper connection with reveal board, vertical section
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
56 von 117
1
2
3
4
5 6 7 7
7
8
9
10
0.048
Wall construction(from inside to outside) Legend:
Recommendation30-50 mm
1 Window sill inside2 Airtight window installation (DIN 4108-7)3 STEICOmulti tape4 STEICOmulti UDB5 STEICOfix wood fibre insulation fillet6 Bonded membrane on insulation fillet7 Joint sealing tape8 Aluminium window sill9 Render stop profile10 Mounted frame for window connection,
also possible with i-joist
- Plasterboard- CLT wall,in connection area airtight tape
- STEICOprotect, fixed withplate washers
- Approved plaster system
Maßstab: 1 : 2.5Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 12-03-2015 Detailnummer: AW-WDVS-MH-3-30
Window - Bottom connection with reveal board, vertical section
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
57 von 117
1
2
4
5
3
6
7
8
9
10
11
External wall construction(from inside to outside)
Roof construction(from inside to outside) Legend:- Visible rafter- Visible sheathing- Vapour barrier- STEICOtherm- STEICOuniversal(below roof covering)
- Counter batten- Support batten- Roof covering
1 Insect screen2 Drip plate3 Blocking panels (notched into rafter)4 Joint sealing tape5 Trowelled joist6 Tilting fillet7 STEICOmulti tape8 Threshold9 Shadow joint10 Angled timber for connecting
the blocking panel11 Blocking panels on room side
- Plasterboard- CLT wall,in connection area airtight tape
- STEICOprotect, fixed withplate washers
- Approved plaster system
Maßstab: 1 : 7.5Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 02-04-2015 Detailnummer: AW-WDVS-MH-6-10
Roof - Transitions - Eaves, above rafter insulation, ETICS on blocking panels
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
58 von 117
12
4
5
6
73
8
External wall construction(from inside to outside) Legend:
Roof construction(from inside to outside)- Plasterboard- Batten- Vapour barrier- STEICOflexsolid wood rafter (glulam)
- STEICOuniversal- Counter batten- Support batten- Roof covering
1 Insect screen2 Drip plate3 Visible eaves sheathing4 Joint sealing tape5 Trowelled joist6 STEICOmulti tape7 Paper joint re-inforcement band filled8 Batten between the rafter
- Plasterboard- CLT wall,in connection area airtight tape
- STEICOprotect, fixed withplate washers
- Approved plaster system
Maßstab: 1 : 7.5Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 02-04-2015 Detailnummer: AW-WDVS-MH-6-20
Roof - Transitions - Eaves, solid wood rafter, ETICS between the rafter
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
59 von 117
12
5
4
3
6
7
Legend:External wall construction(from inside to outside)
Roof construction(from inside to outside)
1 Insect screen2 Drip plate3 Blocking panels (notched into rafter)4 Joint sealing tape5 Trowelled joist6 STEICOmulti tape7 Paper joint re-inforcement band filled
- Plasterboard- Batten- Vapour barrier- STEICOflexsolid wood rafter (glulam)
- STEICOuniversal- Counter batten- Support batten- Roof covering
- Plasterboard- CLT wall,in connection area airtight tape
- STEICOprotect, fixed withplate washers
- Approved plaster system
Maßstab: 1 : 7.5Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 02-04-2015 Detailnummer: AW-WDVS-MH-6-30
Roof - Transitions - Eaves, solid wood rafter with blocking panels
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
60 von 117
1
2
4
5
3
67
8
External wall construction(from inside to outside) Legend:
Roof construction(from inside to outside
1 Insect screen2 Drip plate3 Blocking panels (notched into rafter)4 Joint sealing tape5 Trowelled joist6 Tilting fillet7 Sealing tape8 Seprerating strips
- Plasterboard- CLT wall,in connection area airtight tape
- STEICOprotect, fixed withplate washers
- Approved plaster system
- Visible CLTelement
- STEICOtherm- STEICOuniversal(below roof covering)
- Counter batten- Support batten- Roof covering
Maßstab: 1 : 7.5Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 02-04-2015 Detailnummer: AW-WDVS-MH-6-40
Roof - Transitions - Eaves, CLT element, ETICS on blocking panels
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
61 von 117
1
3
4
65
2
7 8
9
Legend:External wall construction(from inside to outside)
Roof construction(from inside to outside- Plasterboard- Batten- Vapour barrier- STEICOflexsolid wood rafter
- STEICOuniversal- Counter batten- Support batten- Roof covering
1 STEICOmulti UDB (only in verge area)2 STEICOmulti tape + STEICOmulti primer3 Visible whitewood - three layer panels4 Visible projecting roof rafter5 Joint sealing tape6 Trowelled joist7 STEICOmulti tape8 Seprerating strips9 Joint trowel
- Plasterboard- CLT wall,in connection area airtight tape
- STEICOprotect, fixed withplate washers
- Approved plaster system
Maßstab: 1 : 7.5Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 02-04-2015 Detailnummer: AW-WDVS-MH-6-50
Roof - Transitions - Verge, visible projecting roof rafter
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
62 von 117
Wall construction(from inside to outside)
Nr. Material Thickness in cm1 Render layer 1.502 Masonry wall 17.503 Render layer 1.504 STEICOflex with STEICO wall 60/160 16.005 STEICOprotect 6.006 Approved plaster system 0.80
63 von 117
0
0
≥ 5
cm
≥ 15
cm
0.292≥ 30 cm
0.30
0
1
2
3
4
5
6
7
8
9 10
14
15
16
12
11
13
17
Wall construction(from inside to outside) Legend:
Sufficient drainage
min
. 30
cm
1 STEICOmulti fill2 Additional mesh tape with sufficient coverage
to ensure surface re-inforcement3 Cement bonded board4 EPS insulation with textured surface5 Sealing in accordance with DIN 18195-46 DPC edge profile7 Below DPC render in accordance with render recommendation
in ground enviroment with flexible, mineral render sealing8 Gravel bed, grain size min. 16/329 Perimeter insulation10 Building weathering protection, min. 15 cm above ground level11 Timber based panel product12 Laminated Veneer Lumber STEICO LVL
for vertical transfer loads13 Bituminous sheeting14 STEICOtherm15 Wet screed16 STEICOsoundstrip17 Mortar levelling layer
- Render layer- Masonry wall- Render layer- STEICOwall optionalsolid timberSTEICOflex
- STEICOprotect- Approved plaster system
Maßstab: 1 : 5.0Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 12-03-2015 Detailnummer: AW-WDVS-MWHU-1-10
DPC - Level threshold, continuous render layer
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
64 von 117
1
6
3
0.30
9
2 7
8
10
1112
5
9
13
4
0≤ 40 mm(DIN 4108 Bbl. 2)
Wall construction(from inside to outside)
Legend:
Sufficient drainage
1 DPC edge profile2 Joint sealing tape3 Trowelled joist4 Below DPC render in accordance with render recommendation
in ground enviroment with flexible, mineral render sealing5 Building weathering protection, min. 15 cm above ground level6 Perimeter insulation7 Timber based panel product8 Laminated Veneer Lumber STEICO LVL
for vertical transfer loads9 Bituminous sheeting10 STEICOtherm11 Wet screed12 STEICOsoundstrip13 Mortar levelling layer
Spl
ash
wat
er z
one
min
. 30
cm
- Render layer- Masonry wall- Render layer- STEICOwall optionalsolid timerSTEICOflex
- STEICOprotect- Approved plaster system
Maßstab: 1 : 5.0Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 12-03-2015 Detailnummer: AW-WDVS-MWHU-1-20
DPC - Elevated threshold (splashback free)
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
65 von 117
0≥
30 c
m
1 2
6
4
8
3
0.10
0
9
10
11
12
13
0≥ 30 cm
7
5
4
0≤ 40 mm(DIN 4108 Bbl. 2)0
≥ 15
cm
14
≥ 15
cm
Sufficient drainage
Wall construction(from inside to outside) Legend:
1 DPC edge profile2 Joint sealing tape3 Cement bonded board4 Perimeter insulation5 Sealing in accordance with DIN 18195-46 Grating7 Below DPC render in accordance with render recommendation
in ground enviroment with flexible, mineral render sealing8 Gravel bed, grain size min. 16/32 mm9 Building weathering protection, min. 15 cm above ground level10 Timber based panel product11 Laminated Veneer Lumber STEICO LVL
for vertical transfer loads12 Bituminous sheeting13 STEICOsoundstrip14 Mortar levelling layer
- Render layer- Masonry wall- Render layer- STEICOwall optionalsolid timberSTEICOflex
- STEICOprotect- Approved plaster system
Maßstab: 1 : 5.0Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 12-03-2015 Detailnummer: AW-WDVS-MWHU-1-30
DPC - Level threshold, grating (terrace)
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
66 von 117
0.300
0.15
0≥
15 c
m
0.252
2 3
6
1
8
7
9
10
1113
14
15
≥ 30 cm
≥ 15 cm
12
16
4
5
0≤ 40 mm(DIN 4108 Bbl. 2)
Wall construction(from inside to outside) Legend:
Sufficient drainage
1 In splash water zone (up to min. 30 cm over ground level)apply cementitious tanking slurry as moisture protection layerbetween upper and lower render
2 DPC edge profile3 Joint sealing tape4 Trowelled joist5 Below DPC render in accordance with render recommendation
in ground enviroment with flexible, mineral render sealing6 Garden edging7 Gravel bed, grain size min. 16/328 Perimeter insulation9 Building weathering protection, min. 15 cm above ground level10 Timber based panel product11 Laminated Veneer Lumber STEICO LVL
for vertical transfer loads12 Bituminous sheeting13 STEICOtherm14 Wet screed15 STEICOsoundstrip16 Mortar levelling layer
- Render layer- Masonry wall- Render layer- STEICOwall optionalsolid timberSTEICOflex
- STEICOprotect- Approved plaster system
Maßstab: 1 : 5.0Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 12-03-2015 Detailnummer: AW-WDVS-MWHU-1-40
DPC - Lower edge threshold min. 15 cm over terrain top edge (gravel bed)
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
67 von 117
0.103
1
23
4
Wall construction(from inside to outside) Legend:
Edge distance
- Render layer- Masonry wall- Render layer- STEICOwall optionalsolid timberSTEICOflex
- STEICOprotect- Approved plaster system
1 Mesh corner angle2 STEICOmulti fill glueing3 Square timber
Broad back staples: min. 6 x 6 cmFixed with plate washers: min. 8 x 8 cm
4 STEICOwall with web insulationoptional solid timber possible
Maßstab: 1 : 5.0Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 12-03-2015 Detailnummer: AW-WDVS-MWHU-2-10
External wall - Transitions - Outside corner with STEICOwall edge beam
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
68 von 117
12
3
4
Detail A, M 1:2,5
Detail A
Wall construction(from inside to outside) Legend:- Render layer- Masonry wall- Render layer- STEICOwall optionalsolid timberSTEICOflex
- STEICOprotect- Approved plaster system
1 STEICOflex installed in advance2 STEICOwall with web insulation
optional solid timber possible3 Expansion joint profile4 STEICOflex
Maßstab: 1 : 5.0Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 12-03-2015 Detailnummer: AW-WDVS-MWHU-2-20
External wall - Transitions - Inside corner with STEICOwall edge beam
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
4
3
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
69 von 117
12
3
4
12
4
3
Wall construction(from inside to outside) Legend:
Var
iatio
n 2:
with
exp
ansi
on jo
int i
n m
ason
ry w
all
Var
iatio
n 1:
with
out e
xpan
sion
join
t in
mas
onry
wal
l
- Render layer- Masonry wall- Render layer- STEICOwall optionalsolid timberSTEICOflex
- STEICOprotect- Approved plaster system
1 Expansion joint profile10-20 mm flexible
2 STEICOflex3 STEICOwall4 Web insulation
Maßstab: 1 : 5.0
Datum: 06-03-2015
Änderung: 04-04-2017 Bearbeiter: A. Luz
Detailnummer: AW-WDVS-MWHU-2-30
External wall - Transitions - Expansion joint
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
70 von 117
0.027ca. 18-22 mm
1
4
5
6
7
8
9
3
10
2
0
Wall construction(from inside to outside) Legend:
Recommendation30-50 mm
- Render layer- Masonry wall- Render layer- STEICOwall optionalsolid timberSTEICOflex
- STEICOprotect- Approved plaster system
1 Airtight window installation (DIN 4108-7)2 Window sill inside3 Fix at the side due to edge distance4 Clean finish render stop bead5 Joint sealing tape6 STEICOmulti fill7 STEICOprotect H reveal board8 Mesh corner angle9 End profile for ETICS suitable10 Aluminium window sill
Maßstab: 1 : 2.5
Datum: 06-03-2015
Änderung: 04-04-2017 Bearbeiter: A. Luz
Detailnummer: AW-WDVS-MWHU-3-10
Window - Side connection with reveal board, horizontal section
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
71 von 117
1
0.075
2
0.048
3
4
5 6 7
7
78
9
10
Wall construction(from inside to outside) Legend:
Recommendation30-50 mm
1 Window sill inside2 Airtight window installation (DIN 4108-7)3 STEICOmulti tape4 STEICOmulti UDB5 STEICOfix wood fibre insulation fillet6 Bonded membrane on insulation fillet7 Joint sealing tape8 Aluminium window sill9 Render stop profile10 Timber connected with frame plugs (pre drilled)
and fixed according to masonry construction(follow manufacturers guidance)
Embedment depthmin. 70 mm
- Render layer- Masonry wall- Render layer- STEICOwall optionalsolid timberSTEICOflex
- STEICOprotect- Approved plaster system
Maßstab: 1 : 3.0Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 12-03-2015 Detailnummer: AW-WDVS-MWHU-3-20
Window - Bottom connection with reveal board, vertical section
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
72 von 117
1
3
45
6
7 8
9
10
7
2
Wall construction(from inside to outside) Legend:- Render layer- Masonry wall- Render layer- STEICOwall optionalsolid timberSTEICOflex
- STEICOprotect- Approved plaster system
1 Airtight window installation (DIN 4108-7)2 Window lintel3 Joint sealing tape4 STEICOprotect H reveal board5 Raffstore6 Raffstore- guide rail7 STEICOmulti fill8 STEICOprotect H reveal board9 Drip edge profile10 Surface mesh
Maßstab: 1 : 3.0Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 12-03-2015 Detailnummer: AW-WDVS-MWHU-5-10
Raffstore - Window - Upper connection with reveal board, vertical section
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
73 von 117
1
2
3 4
5
6 7
8
9
10
External wall construction(from inside to outside)
Roof construction(from inside to outside) Legend:
1 Insect screen2 Drip plate3 Rafter doubling4 STEICOmulti UDB (only in eaves zone)5 Blocking panels6 Joint sealing tape7 Trowelled joist8 STEICOmulti tape + STEICOmulti primer9 Render board10 Permanent elastic joint
- Render layer- Masonry wall- Render layer- STEICOwall optionalsolid timberSTEICOflex
- STEICOprotect- Approved plaster system
- Plasterboard- Batten- Vapour barrier- STEICOflexsolid timber rafter
- STEICOuniversal- Counter batten- Support batten- Roof covering
Maßstab: 1 : 7.5Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 02-04-2015 Detailnummer: AW-WDVS-MWHU-6-10
Roof - Transitions - Eaves, solid wood rafter with blocking panels
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
74 von 117
1 2
3
4
65
7 9
External wall construction(from inside to outside)
Roof construction(from inside to outside) Legend:
1 STEICOmulti UDB (only in verge area)2 STEICOmulti tape + STEICOmulti primer3 Visible whitewood - three layer panels4 Visible projecting roof rafter5 Joint sealing tape6 Trowelled joist7 Seprerating strips8 Joint trowell
- Plasterboard- Batten- Vapour barrier- STEICOflexsolid timber rafter
- STEICOuniversal- Counter batten- Support batten- Roof covering
- Render layer- Masonry wall- Render layer- STEICOwall optionalsolid timberSTEICOflex
- STEICOprotect- Approved plaster system
Maßstab: 1 : 7.5Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 02-04-2015 Detailnummer: AW-WDVS-MWHU-6-20
Roof - Transitions - Verge, visible projecting roof rafter
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
75 von 117
1
2
3
Legend:External wall construction(from inside to outside)
Ceiling construction(from top to bottom)- Floor covering- Screeds- Sheeting- Impact soundinsulation
- Reinforced concreteceiling
- Render layer
- Render layer- Masonry wall- Render layer- STEICOwall optionalsolid timberSTEICOflex
- STEICOprotect- Approved plaster system
1 Timber based board for seperating the insulation zoneNote:Verical insulation zones should be seperatedat each storey or a minimum of every 3m witha structural seperation. The seperation of theinsulation zone increases the installation qualitywhen using air injected insulations.
2 Approved angle connectore.g. 90 mm x 48 mm x 76 mmfixed with min. 4 CSA screws per angle
3 Approved frame plug
Maßstab: 1 : 5.0Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 12-03-2015 Detailnummer: AW-WDVS-MWHU-7-10
Ceiling - Transitions - I-Joist joint horizontal
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
76 von 117
Nr. Material Thickness in cm1 Inside render 1.502 Masonry wall 24.003 Mortar resin 1.004 STEICOprotect L dry 16.005 Approved plaster system 0.80
Wall construction (New build)(from inside to outside)
77 von 117
1 2
3
4
5
60.05
0
7
8
9
10
11
13
14
15
≥ 5
cm
120
0
0.30
9
16
≤ 40 mm(DIN 4108 Bbl. 2)
Fall min. 2%
Spl
ash
wat
er z
one
min
. 30
cm
Wall construction(from inside to outside)
Legend:
1 DPC edge profile2 Joint sealing tape3 Trowelled joist4 Below DPC render in accordance with render recommendation
in ground enviroment with flexible, mineral render sealing5 Perimeter insulation6 Flexible, mineral render sealing7 Finished floor covering (= water-carrying layer) min. 2% fall8 Protective layer, e.g. dimpled drainage layer9 Mortar resin suitable for weathering protection10 Building weathering protection in accordance with
DIN 18195 min. 15 cm above ground level11 Mortar resin12 Bituminous sheeting13 STEICOtherm14 Wet screed15 STEICOsoundstrip16 Mortar levelling layer
min. 50 mm taken onto the insulation board
- Render layer- Masonry wall- Mortar resin- STEICOprotect L dry- Approved plaster system
Maßstab: 1 : 5.0Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 12-03-2015 Detailnummer: AW-WDVS-MWG-1-10
DPC - New build - Heated basement - Ground level below top edge of concrete ceiling
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
78 von 117
0.308
1 2
3
4
5
60.05
0
7
8
13
14
15
≥ 30 cm
≥ 5
cm
0.14
7≥
15
cm
11
10
9
12
0
0
0.30
9
16
≤ 40 mm(DIN 4108 Bbl. 2)
Sufficient drainage
Wall construction(from inside to outside)
Spl
ash
wat
er z
one
min
. 30
cm
Legend:
1 DPC edge profile2 Joint sealing tape3 Trowelled joist4 Below DPC render in accordance with render recommendation
in ground enviroment with flexible, mineral render sealing5 Perimeter insulation6 Flexible, mineral render sealing7 Gravel bed, grain size min. 16/328 Protective layer, e.g. dimpled drainage layer9 Mortar resin suitable for weathering protection10 Building weathering protection in accordance with DIN 18195
min. 15 cm above ground level11 Mortar resin12 Bituminous sheeting13 STEICOtherm14 Wet screed15 STEICOsoundstrip16 Mortar levelling layer
min. 50 mm taken onto the insulation board
- Render layer- Masonry wall- Mortar resin- STEICOprotect L dry- Approved plaster system
Maßstab: 1 : 5.0Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 12-03-2015 Detailnummer: AW-WDVS-MWG-1-20
DPC - New build - Heated basement - Ground level on top edge of concrete ceiling
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
79 von 117
0.308
1 2
3
4
5
60.05
0
7
8
14
15
≥ 5
cm
1213
0
0.30
9
0
160.
500
≥ 30 cm
≥ 50
0 m
m (
DIN
410
8 B
bl. 2
)
9
10
11 17
≤ 40 mm(DIN 4108 Bbl. 2)
Sufficient drainage
Wall construction(from inside to outside)
Legend:
Spl
ash
wat
er z
one
min
. 30
cm
min. 50 mm taken onto the insulation board
1 DPC edge profile2 Joint sealing tape3 Trowelled joist4 Below DPC render in accordance with render recommendation
in ground enviroment with flexible, mineral render sealing5 Perimeter insulation6 Flexible, mineral render sealing7 Gravel bed, grain size min. 16/328 Protective layer, e.g. dimpled drainage layer9 Capillary breaking seperation approx. 20mm wide,
sealed with a flexible mineral sealant10 Building weathering protection in accordance
with DIN 18195 min. 15 cm above ground level11 Mortar resin suitable for old render12 Bituminous sheeting13 STEICOtherm14 Wet screed15 STEICOsoundstrip16 Mortar levelling layer17 Basement ceiling insulation in accordance with requirements
- Render layer- Masonry wall- Mortar resin- STEICOprotect L dry- Approved plaster system
Maßstab: 1 : 5.0Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 12-03-2015 Detailnummer: AW-WDVS-MWG-1-30
DPC - Existing - Un-heated basement - Ground level below top edge of concrete ceiling
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
80 von 117
1
4
8
9
7
6
3
3
2
10
0
4
5
0.020ca. 18-22 mm
Wall construction(from inside to outside) Legend:
Recommendation30-50 mm
1 Airtight window installation (DIN 4108-7)2 Window sill inside3 Mortar resin4 Clean finish render stop bead5 Joint sealing tape6 STEICOmulti fill glueing7 STEICOprotect dry reveal board 20 mm8 Mesh corner angle9 End profile for ETICS suitable10 Aluminium window sill
- Render layer- Masonry wall- Mortar resin- STEICOprotect L dry- Approved plaster system
Maßstab: 1 : 2.5
Datum: 06-03-2015
Änderung: 04-04-2017 Bearbeiter: A. Luz
Detailnummer: AW-WDVS-MWG-3-10
Window - New build - Side connection with reveal board, horizontal section
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
81 von 117
1
2 34
5 5
6
7
8
2
Wall construction(from inside to outside) Legend:
1 Airtight window installation (DIN 4108-7)2 Clean finish render stop bead3 Joint sealing tape4 STEICOprotect dry reveal board 20 mm5 Mortar resin6 Drip edge profile7 STEICOmulti fill glueing8 Surface mesh
- Render layer- Masonry wall- Mortar resin- STEICOprotect L dry- Approved plaster system
Maßstab: 1 : 3.0Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 11-03-2015 Detailnummer: AW-WDVS-MWG-3-20
Window - New build - Upper connection with reveal board, vertical section
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
82 von 117
1 2
0
3
4
5 6 77
7
8
9
10
11
Wall construction(from inside to outside) Legend:
Recommendation30-50 mm
1 Window sill inside2 Airtight window installation (DIN 4108-7)3 STEICOmulti tape4 STEICOmulti UDB5 STEICOfix wood fibre insulation fillet6 Bonded membrane on wood fibre insulation fillet7 Joint sealing tape8 Aluminium window sill9 Parapet profile10 STEICOmulti fill glueing11 Mortar resin
- Render layer- Masonry wall- Mortar resin- STEICOprotect L dry- Approved plaster system
Maßstab: 1 : 3.0Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 12-03-2015 Detailnummer: AW-WDVS-MWG-3-30
Window - New building - Bottom connection with reveal board, vertical section
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
83 von 117
Roof construction(from inside to outside)
Nr. Material Thickness in cm1 Plasterboard 1.252 Batten 24 x 48 2.403 Vapour barrier -4 STEICOflex with STEICO joist 60/300 30.005 STEICOuniversal 3.506 Counter batten 40 x 60 4.007 Support batten 30 x 50 3.008 Roof covering
84 von 117
1
2
3
4
5
6
7 8
9
Roof construction(from inside to outside) Legend:- Plasterboard- Batten- Vapour barrier- STEICOflexSTEICOjoist
- STEICOuniversal- Counter batten- Support batten- Roof covering
1 Mounting cover fixed after screwing of the STEICO joiston the ridge purlin and filling of the insulation zone
2 STEICOmulti UDB3 Possibly tension strap (DN > 30°)4 Ridge area after element assembly filled with STEICOflex5 Fully threaded screws max. t = 6 mm (pre-drilled).6 Place sheeting strips (vapour barrier) above ridge purlin
before assembly of the roof elements and then connect together7 Pasterboard mounting cover8 Filling with seprerating strips on the ridge purlin9 Web insulation
Maßstab: 1 : 7.5Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 23-03-2015 Detailnummer: DA-SD-ZSD-1-10
Ridge - Sloped purlin - Element assembly with fixing point
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
85 von 117
12
3
4
5
6
7
8
9
Roof construction(from inside to outside) Legend:- Plasterboard- Batten- Vapour barrier- STEICOflexSTEICOjoist
- STEICOuniversal- Counter batten- Support batten- Roof covering
1 Last support batten, on-site assembled2 Ridge batten holder, on-site assembled3 Roofing felt taped on the ridge4 STEICOmulti UDB, only in ridge area5 Part thread screw (mushroom top), (pre-drilled)6 Element end e.g. 15 mm OSB,
if required consider insulating between elements7 Support fillet, Laminated Veneer Lumber STEICO LVL R8 Pre-compressed sealing tape connected to element9 Filling with seprerating strips on the ridge purlin
(seprerating strips cut off after filling)
Maßstab: 1 : 7.5Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 23-03-2015 Detailnummer: DA-SD-ZSD-1-20
Ridge - Rectangular purlin - Element assembly
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
86 von 117
1
2
3
4
5
Roof construction(from inside to outside) Legend:- Plasterboard- Batten- Vapour barrier- STEICOflexSTEICOjoist
- STEICOuniversal- Counter batten- Support batten- Roof covering
1 STEICOmulti tape + STEICOmulti primer2 Possibly tension strap (DN > 30°)3 Steel sheet e.g. LSSUI 35 "Simpson Strong- Tie"4 Taping (vapour barrier stripe), airtight tape5 Paper joint re-inforcement band filled
Maßstab: 1 : 7.5Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 23-03-2015 Detailnummer: DA-SD-ZSD-1-30
Ridge - Side connection with metalwork
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
87 von 117
1
2
3
4 5
6
7
8
9
10
1112
External wall construction(from inside to outside)
Roof construction(from inside to outside) Legend:
- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- Approved plaster system
- Plasterboard- Batten- Vapour barrier- STEICOzellSTEICOjoist
- STEICOuniversal- Counter batten- Support batten- Roof covering
1 STEICOmulti UDB (only in eaves zone)2 STEICOuniversal 22 mm, assembled on site3 STEICO LVL-X 39 mm with surface treatment,
on site fitted projecting roof board4 Joint sealing tape5 Trowelled joist6 STEICOprotect H, adjusted on site7 STEICOflex in assembled frame8 STEICO LVL X sheat cleat9 I-Joist as studs10 STEICOzell in insulation zone11 STEICOuniversal 60 mm, factory assembled12 STEICOmulti tape + STEICOmulti primer
Maßstab: 1 : 7.5Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 02-04-2015 Detailnummer: AW-WDVS-HRB-6-10
Roof - Transitions - Eaves, STEICO LVL projecting roof board (without rafter doubling)
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
88 von 117
12 6
7
34
5
External wall construction(from inside to outside)
Roof construction(from inside to outside) Legend:
- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- Approved plaster system
1 Insect screen2 Drip plate3 Blocking between the rafters4 Joint sealing tape5 Trowelled joist6 STEICO LVL Laminated Veneer Lumber7 Paper joint re-inforcement band filled
- Plasterboard- Batten- Vapour barrier- STEICOflexSolid wood rafter (Glulam)
- STEICOuniversal- Counter batten- Support batten- Roof covering
Maßstab: 1 : 7.5Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 02-04-2015 Detailnummer: AW-WDVS-HRB-6-30
Roof - Transitions - Eaves, solid wood rafter, ETICS between the rafter
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
89 von 117
12
5
6
7
4
3
Legend:External wall construction(from inside to outside)
Roof construction(from inside to outside)
- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- Approved plaster system
1 Insect screen2 Drip plate3 Blocking panels (notched into rafter)4 Joint sealing tape5 Trowelled joist6 STEICO LVL Laminated Veneer Lumber7 Paper joint re-inforcement band fille
- Plasterboard- Batten- Vapour barrier- STEICOflexSolid wood rafter (Glulam)
- STEICOuniversal- Counter batten- Support batten- Roof covering
Maßstab: 1 : 7.5Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 02-04-2015 Detailnummer: AW-WDVS-HRB-6-40
Roof - Transitions - Eaves, solid wood rafter with blocking panels
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
90 von 117
12
3
7
8
6
4
5
External wall construction(from inside to outside)
Roof construction(from inside to outside) Legend:
- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- Approved plaster system
1 Insect screen2 Drip plate3 Blocking panels (notched into rafter)4 Joint sealing tape5 Trowelled joist6 End timber7 STEICO LVL Laminated Veneer Lumber8 Paper joint re-inforcement band fille
- Plasterboard- Batten- Vapour barrier- STEICOflexSolid wood rafter (Glulam)
- STEICOuniversal- Counter batten- Support batten- Roof covering
Maßstab: 1 : 7.5Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 02-04-2015 Detailnummer: AW-WDVS-HRB-6-50
Roof - Transitions - Eaves, with end timber (element assembly)
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
91 von 117
12
4
5
6
73
8
External wall construction(from inside to outside) Legend:
Roof construction(from inside to outside)- Plasterboard- Batten- Vapour barrier- STEICOflexsolid wood rafter (glulam)
- STEICOuniversal- Counter batten- Support batten- Roof covering
1 Insect screen2 Drip plate3 Visible eaves sheathing4 Joint sealing tape5 Trowelled joist6 STEICOmulti tape7 Paper joint re-inforcement band filled8 Batten between the rafter
- Plasterboard- CLT wall,in connection area airtight tape
- STEICOprotect, fixed withplate washers
- Approved plaster system
Maßstab: 1 : 7.5Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 02-04-2015 Detailnummer: AW-WDVS-MH-6-20
Roof - Transitions - Eaves, solid wood rafter, ETICS between the rafter
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
92 von 117
12
5
4
3
6
7
Legend:External wall construction(from inside to outside)
Roof construction(from inside to outside)
1 Insect screen2 Drip plate3 Blocking panels (notched into rafter)4 Joint sealing tape5 Trowelled joist6 STEICOmulti tape7 Paper joint re-inforcement band filled
- Plasterboard- Batten- Vapour barrier- STEICOflexsolid wood rafter (glulam)
- STEICOuniversal- Counter batten- Support batten- Roof covering
- Plasterboard- CLT wall,in connection area airtight tape
- STEICOprotect, fixed withplate washers
- Approved plaster system
Maßstab: 1 : 7.5Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 02-04-2015 Detailnummer: AW-WDVS-MH-6-30
Roof - Transitions - Eaves, solid wood rafter with blocking panels
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
93 von 117
1
2
3 4
5
6 7
8
9
10
External wall construction(from inside to outside)
Roof construction(from inside to outside) Legend:
1 Insect screen2 Drip plate3 Rafter doubling4 STEICOmulti UDB (only in eaves zone)5 Blocking panels6 Joint sealing tape7 Trowelled joist8 STEICOmulti tape + STEICOmulti primer9 Render board10 Permanent elastic joint
- Render layer- Masonry wall- Render layer- STEICOwall optionalsolid timberSTEICOflex
- STEICOprotect- Approved plaster system
- Plasterboard- Batten- Vapour barrier- STEICOflexsolid timber rafter
- STEICOuniversal- Counter batten- Support batten- Roof covering
Maßstab: 1 : 7.5Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 02-04-2015 Detailnummer: AW-WDVS-MWHU-6-10
Roof - Transitions - Eaves, solid wood rafter with blocking panels
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
94 von 117
2
3
6
7
8
9
Detail A, M 1:2,5
10
15
4Detail A
External wall construction(from inside to outside)
Roof construction(from inside to outside) Legend:
- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- Approved plaster system
- Plasterboard- Batten- Vapour barrier- STEICOzellSTEICOjoist
- STEICOuniversal- Counter batten- Support batten- Roof covering
1 STEICOmulti UDB (only in verge area )2 STEICOuniversal 22 mm3 STEICO LVL-X 39 mm with surface treatment4 STEICOmulti tape + STEICOmulti primer5 STEICOuniversal 60 mm on the roof surface6 Web insulation7 Compressable insulation at connection8 Mounting cover9 Joint sealing tape10 Trowelled joist
Maßstab: 1 : 7.5Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 02-04-2015 Detailnummer: AW-WDVS-HRB-6-60
Roof - Transitions - Eaves, STEICO LVL projecting roof board (without rafter doubling)
54
2
1
3
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
95 von 117
5
2
1
4
8
9
67
3
External wall construction(from inside to outside) Legend:- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- Approved plaster system
Roof construction(from inside to outside)
1 STEICOmulti UDB (only in verge area)2 Visible soffit board3 End timber4 Joint sealing tape5 Trowelled joist6 STEICO LVL Laminated Veneer Lumber7 Solid wood rafter or optional STEICOjoist8 STEICOmulti tape + STEICOmulti primer9 STEICOmulti tape
- Plasterboard- Batten- Vapour barrier- STEICOflexSolid wood rafter (Glulam)
- STEICOuniversal- Counter batten- Support batten- Roof covering
Maßstab: 1 : 7.5Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 02-04-2015 Detailnummer: AW-WDVS-HRB-6-80
Roof - Transitions - Verge, with end timber (element assembly)
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
96 von 117
1
3
4
65
2
7 8
9
Legend:External wall construction(from inside to outside)
Roof construction(from inside to outside- Plasterboard- Batten- Vapour barrier- STEICOflexsolid wood rafter
- STEICOuniversal- Counter batten- Support batten- Roof covering
1 STEICOmulti UDB (only in verge area)2 STEICOmulti tape + STEICOmulti primer3 Visible whitewood - three layer panels4 Visible projecting roof rafter5 Joint sealing tape6 Trowelled joist7 STEICOmulti tape8 Seprerating strips9 Joint trowel
- Plasterboard- CLT wall,in connection area airtight tape
- STEICOprotect, fixed withplate washers
- Approved plaster system
Maßstab: 1 : 7.5Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 02-04-2015 Detailnummer: AW-WDVS-MH-6-50
Roof - Transitions - Verge, visible projecting roof rafter
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
97 von 117
1 2
3
4
65
7 9
External wall construction(from inside to outside)
Roof construction(from inside to outside) Legend:
1 STEICOmulti UDB (only in verge area)2 STEICOmulti tape + STEICOmulti primer3 Visible whitewood - three layer panels4 Visible projecting roof rafter5 Joint sealing tape6 Trowelled joist7 Seprerating strips8 Joint trowell
- Plasterboard- Batten- Vapour barrier- STEICOflexsolid timber rafter
- STEICOuniversal- Counter batten- Support batten- Roof covering
- Render layer- Masonry wall- Render layer- STEICOwall optionalsolid timberSTEICOflex
- STEICOprotect- Approved plaster system
Maßstab: 1 : 7.5Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 02-04-2015 Detailnummer: AW-WDVS-MWHU-6-20
Roof - Transitions - Verge, visible projecting roof rafter
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
98 von 117
ITSE1
2
3
4
1
2
5
6
7
IUSE
Roof construction(from inside to outside) Legend:- Plasterboard- Batten- Vapour barrier- STEICOflexSTEICOjoist
- STEICOuniversal- Counter batten- Support batten- Roof covering
Connectiontrimmer on rafter
Trimmer
1 Timmer I-Joist STEICOjoist2 Filling timber3 Metal sheet Simpson Strong-Tie ITSE4 Metal sheet Simpson Strong-Tie IUSE5 Flashing and water drainage channel6 Interior lining rooflight7 STEICOmulti tape + STEICOmulti primer
Maßstab: 1 : 7.5Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 23-03-2015 Detailnummer: DA-SD-ZSD-4-10
Rooflight - Trimmer connection with metalwork
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
4 43
2
2
2
Bottom view M 1:10
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
99 von 117
1
2
3
4
56
2
7
8
9
Roof construction(from inside to outside) Legend:- Plasterboard- Batten- Vapour barrier- STEICOflexSTEICOjoist
- STEICOuniversal- Counter batten- Support batten- Roof covering
Connectiontrimmer on rafter
Trimmer
1 Trimmer I-Joist STEICOjoist2 Laminated Veneer Lumber plate STEICO LVL X3 Fully threaded screws, 2 piece per connection4 Part trhreade screw, only structural, 2 piece per connection5 Notch on rafter6 Staples only structual7 Flashing and water drainage channel8 Interior lining rooflight9 STEICOmulti tape + STEICOmulti primer
Maßstab: 1 : 7.5Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 23-03-2015 Detailnummer: DA-SD-ZSD-4-20
Rooflight - Trimmer connection without metalwork
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
23
45
5
3
6
Bottom view M 1:10
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
100 von 117
1
2
4
5
3
Detail A
6Detail B
Roof construction(from inside to outside) Legend:- Plasterboard- Batten- Vapour barrier- STEICOflexSTEICOjoist
- STEICOuniversal- Counter batten- Support batten- Roof covering
1 Nail tight tape2 Web insulation3 Compressable insulation at connection4 STEICOmulti tape5 Connection plate STEICO LVL X Laminated Veneer Lumber6 Plasterboard mounting cover
Maßstab: 1 : 7.5Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 02-04-2015 Detailnummer: DA-SD-ZSD-5-10
Element joint - Roof element joint
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
1
23
Detail A, M 1:5 0≥ 30 mm
6
5
4
Datail B, M 1:5
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
101 von 117
1
2
5 6
3
- Plasterboard- Batten- Vapour barrier- STEICOflexSTEICOjoist
- STEICOuniversal- Counter batten- Support batten- Roof covering
Roof construction(from inside to outside)
Intermediate floor construction(from top to bottom)
Legend:
Non inhabited roof space
- Floorboard- STEICOflexSTEICOjoist
- Vapour barrier- Batten- Plasterboard
Viewing direction
1 Filling timber2 Laminated Veneer Lumber STEICO LVL
angle timber3 Collar beam4 Rafter, STEICOjoist5 STEICOmulti tape, airtight tape6 Paper re-inforcement band filled
Maßstab: 1 : 7.5Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 23-03-2015 Detailnummer: DA-SD-ZSD-6-10
Collar tie connection
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
22
11
4
31
View from outside (simplified) M 1:10
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
102 von 117
1
2
3
0.18
5
Detail A
Detail A, M 1:1
7
min
. 15
cm
Roof construction(from inside to outside) Legend:
- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- Approved plaster system
- Plasterboard- Batten- Vapour barrier- STEICOflexSTEICOjoist
- STEICOuniversal- Counter batten- Support batten- Roof covering
1 Foam wedge2 Taping, roofing felt in connection area3 Metal sheet as gutter4 Screw plug5 Re-inforced render including mesh
with water repellent highly cured,cementitious tanking membrane
6 Metal connection profile7 Corner angle
Wall construction (Gable)(from inside to outside)
Maßstab: 1 : 5.0Änderung: 22-03-2017 Bearbeiter: A. Luz
Datum: 23-03-2015 Detailnummer: AW-WDVS-HRB-6-90
Roof - Transitions - Gable cheek, continuous wall
45
6
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
103 von 117
1
2
3
45
6
7
8
9
0.16
2
10
min
. 15
cm
Wall construction(from inside to outside)
Roof construction(from inside to outside) Legend:
- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- Approved plaster system
- Plasterboard- Batten- Vapour barrier- STEICOflexSTEICOjoist
- STEICOuniversal- Counter batten- Support batten- Roof covering
1 Re-inforced render including meshwith water repellent highly cured,cementitious tanking membrane
2 Metal connection profile3 Screw plug4 Wall connection tape
metal sheet upstand with lapped lead5 STEICO LVL Laminated Veneer Lumber6 Tension strap (14° - 45°)7 Vented tile8 Air gap ca. 5 mm9 Roofing felt in connection area,
taped with STEICOmulti tape10 Glulam beam
Maßstab: 1 : 5.0Änderung: 30-03-2017 Bearbeiter: A. Luz
Datum: 23-03-2015 Detailnummer: AW-WDVS-HRB-6-100
Roof - Transitions - Connection to single pitch roof without rear ventilation
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
104 von 117
Roof construction(from inside to outside)
Nr. Material Thickness in cm1 Visible rafter 16.002 Timber cladding 1.903 Vapour barrier -4 STEICOftherm 20.005 STEICOuniversal (below roof covering) 3.506 Counter batten 40 x 60 4.007 Support batten 30 x 50 3.008 Roof covering
105 von 117
1
2
3
4
Roof construction(from inside to outside) Legend:- Visible rafter- Timber cladding- Vapour barrier- STEICOtherm- STEICOuniversal- Counter batten- Support batten- Roof covering
1 Ridge batten support2 STEICOmulti UDB, only in ridge zone
if required STEICOmulti tape + STEICOmulti primer3 Single thread screw to secure for wind suction loads4 Single thread screw to secure against shear loads
Maßstab: 1 : 7.5Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 23-03-2015 Detailnummer: DA-SD-ADD-1-10
Ridge - Purlin roof truss
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
106 von 117
1
2
4
5
3
6
7
8
9
10
11
External wall construction(from inside to outside)
Roof construction(from inside to outside) Legend:- Visible rafter- Visible sheathing- Vapour barrier- STEICOtherm- STEICOuniversal(below roof covering)
- Counter batten- Support batten- Roof covering
1 Insect screen2 Drip plate3 Blocking panels (notched into rafter)4 Joint sealing tape5 Trowelled joist6 Tilting fillet7 STEICOmulti tape8 Threshold9 Shadow joint10 Angled timber for connecting
the blocking panel11 Blocking panels on room side
- Plasterboard- CLT wall,in connection area airtight tape
- STEICOprotect, fixed withplate washers
- Approved plaster system
Maßstab: 1 : 7.5Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 02-04-2015 Detailnummer: AW-WDVS-MH-6-10
Roof - Transitions - Eaves, above rafter insulation, ETICS on blocking panels
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
107 von 117
1
2
4
5
3
67
8
External wall construction(from inside to outside) Legend:
Roof construction(from inside to outside
1 Insect screen2 Drip plate3 Blocking panels (notched into rafter)4 Joint sealing tape5 Trowelled joist6 Tilting fillet7 Sealing tape8 Seprerating strips
- Plasterboard- CLT wall,in connection area airtight tape
- STEICOprotect, fixed withplate washers
- Approved plaster system
- Visible CLTelement
- STEICOtherm- STEICOuniversal(below roof covering)
- Counter batten- Support batten- Roof covering
Maßstab: 1 : 7.5Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 02-04-2015 Detailnummer: AW-WDVS-MH-6-40
Roof - Transitions - Eaves, CLT element, ETICS on blocking panels
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
108 von 117
1
2
4
5
9
610
3
7 8
11
External wall construction(from inside to outside) Legend:- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- Approved plaster system
1 Insect screen2 Drip plate3 Blocking panel (notched into rafter)4 Joint sealing tape5 Trowelled joist6 STEICO LVL Laminated Veneer Lumber7 Angled timber for connecting the blocking panel8 Blocking panel on room side9 Shadow joint10 STEICOmulti tape11 Tilting fillet
Roof construction(from inside to outside)- Visible rafter- Visible sheathing- Vapour barrier- STEICOtherm- STEICOuniversal(below roof covering)
- Counter batten- Support batten- Roof covering
Maßstab: 1 : 7.5Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 02-04-2015 Detailnummer: AW-WDVS-HRB-6-20
Roof - Transitions - Eaves, above rafter insulation, ETICS on blocking panels
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
109 von 117
1
23
4
5
6
7
8
9
10
External wall construction(from inside to outside)
Roof construction(from inside to outside) Legend:
- Plasterboard- OSB, airtight tape- STEICOflexSTEICOwall
- STEICOprotect- Approved plaster system
- Visible rafter- Visible sheathing- Vapour barrier- STEICOtherm- STEICOuniversal(below roof covering)
- Counter batten- Support batten- Roof covering
1 Visible verge sheathing2 Visible projecting roof rafter3 End of insulation leyer, windproofness4 Joint sealing tape5 Trowelled joist6 Purlin doubling7 Purlin8 STEICOmulti tape9 Visible rafter10 Shadow joint
Maßstab: 1 : 7.5Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 02-04-2015 Detailnummer: AW-WDVS-HRB-6-70
Roof - Transitions - Verge, visible projecting roof rafter, above rafter insulation
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
110 von 117
1
2
3
4
5
6
7
Roof construction(from inside to outside) Legend:- Visible rafter- Timber cladding- Vapour barrier- STEICOtherm- STEICOuniversal- Counter batten- Support batten- Roof covering
1 Trimmer2 Cover strip interior lining3 Interior lining4 Airtight tape5 Flashing and water drainage channel6 STEICOmulti tape + STEICOmulti primer7 STEICOflex
Maßstab: 1 : 7.5Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 23-03-2015 Detailnummer: DA-SD-ADD-4-10
Rooflight
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
111 von 117
0ca.10 cm
1
2
3
Roof construction(from inside to outside) Legend:- Visible rafter- Timber cladding- Vapour barrier- STEICOtherm- STEICOuniversal- Counter batten- Support batten- Roof covering
Note:The safe long term load transfer and connection for Wind and Suction loads must be in line withrequirements of the STEICO woodfibre insulation. Structurally approved fastners, which specificallymake reference to the compressive strength of the insulation material allow the creation of astructural recommendation.
Data entry sheets for the creation of a structural recommendation are available on our homepage at:www.steico.com under Download / Technik-Verarbeitung/Eingabeblaetter
1 Dual threaded screw to secure for wind suctionloads in 90° angle to rafter axis(spacing based on structural requirements)
2 Dual threaded screw(v-screwing) in default angle to rafter axis to secureagainst shear loads(spacing based on structural requirements)
3 Details in accordance with screw manufacturer
Maßstab: 1 : 7.5Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 23-03-2015 Detailnummer: DA-SD-ADD-7-10
Fixed with dual threaded screws, v-screwing, above rafter insulation
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
112 von 117
1
2
3
Roof construction(from inside to outside) Legend:- Visible rafter- Timber cladding- Vapour barrier- STEICOtherm- STEICOuniversal- Counter batten- Support batten- Roof covering
Note:The safe long term load transfer and connection for Wind and Suction loads must be in line withrequirements of the STEICO woodfibre insulation. Structurally approved fastners, which specificallymake reference to the compressive strength of the insulation material allow the creation of astructural recommendation.
Data entry sheets for the creation of a structural recommendation are available on our homepage at:www.steico.com under Download / Technik-Verarbeitung/Eingabeblaetter
1 Single threaded screw to secure for wind suctionloads in 90° angle to rafter axis(spacing based on structural requirements)
2 Single threaded screw in default angleto rafter axis to secure against shear loads(spacing based on structural requirements)
3 Details in accordance with screw manufacturer
Maßstab: 1 : 7.5Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 23-03-2015 Detailnummer: DA-SD-ADD-7-20
Fixed with single threaded screw, above rafter insulation
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
113 von 117
1
Roof construction(from inside to outside) Legend:- Visible rafter- Timber cladding- Vapour barrier- STEICOtherm- STEICOuniversal- Counter batten- Support batten- Roof covering
1 Single thread screw(Spacing based on structural requirements)
Maßstab: 1 : 7.5Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 23-03-2015 Detailnummer: DA-SD-ADD-7-30
Rafter doubling with STEICO joist, above rafter insulation
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
114 von 117
1
2
34
56
Roof construction(from inside to outside) Legend:- Visible rafter- Timber cladding- Vapour barrier- STEICOtherm- STEICOuniversal- Counter batten- Support batten- Roof covering
1 Single threaded screw to secure against shear loads2 Single threaded screw to secure for wind suction loads3 Foam wedge to secure against water pressure4 Valley plate on timber cladding5 STEICOmulti tape + STEICOmulti primer6 STEICOmulti UDB, only in valley zone
Maßstab: 1 : 7.5Änderung: 04-04-2017 Bearbeiter: A. Luz
Datum: 23-03-2015 Detailnummer: DA-SD-ADD-7-40
Valley - Purlin roof truss
Important Note:The preceding details should only be used for planning purposes. Their accuracy, completeness and suitability should be checkedby the installer / designer independently to ensure compliance with the relevant regulatory requirements. They should not be used to replaceindividual project detailing but to assist the project designer in the detailing process.
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
115 von 117
Thick full line - visible edges, edges
Thin full line - dimension line, reference line, light edges, hatching, projected line
Dashed line - hide edges
Chain line - section plane, symmetry line, movement line
Masonry wall
Gravel, broken stones
Render layer, plasterboard
System render (consisting from re-inforced render,re-inforcement mesh, finish render)
Insulation: e.g. STEICO protect
Concrete re-inforced
Timber surface side
Timber face side
STEICO Laminated Veneer Lumber
Timber based panel product e.g. OSB
Sealing e.g. joint sealing tape
Sealing diffusion openroofing felt
Sealing diffusion open + retardant + diffusion resistantVapour barrier
Cross Laminated Timber (CLT)
Insulation materials
STEICOmulti fill
Insect screen
Maßstab: 1 : 2.5
Datum: 10-03-2015
Änderung: 07-04-2017 Bearbeiter: A. Luz
Detailnummer: -
Legend hatching
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
116 von 117
Expansion joint profile (10 mm - 20 mm flexible)
End profile(End of render layer on mesh component)
Mesh corner angle
Metal connection profileScrews plug
Drip edge profile
DPC metal connection profile = STEICO protectDPC metal connection profile
Clean finish render stop bead = STEICO protectclean finish render stop bead
DPC edge profile(edge side glueing)
Maßstab: 1 : 5.0
Datum: 10-03-2015
Änderung: 04-04-2017 Bearbeiter: A. Luz
Detailnummer: -
Legend profiles
STEICO SE * Otto-Lilienthal-Ring 30 * D-85622 Feldkirchen * TEL 0 89 - 99 15 51 0 FAX: 0 89 - 99 15 51 26 www.steico.com
117 von 117