0(*1 · Cylindrical Lock, Eclipse or Galaxy Lever (2) PTH-4Q –4.5"x4.5" Power Transfer Hinge...
Transcript of 0(*1 · Cylindrical Lock, Eclipse or Galaxy Lever (2) PTH-4Q –4.5"x4.5" Power Transfer Hinge...
-
WWW.SDCSECURITY.COM ■ SECURITY DOOR CONTROLS
Security Door ControlsACCESS & EGRESS SOLUTIONS - THE LOCK BEHIND THE SYSTEM 1
Communicating Bathroom PackagePre-spec’d so you don’t have to. One part number covers it all, whether you’re looking for a mortise, cylindrical, or electromagnetic locking system. Each Shared Bathroom Package is complete with everything needed to ensure privacy and coordinate emergency access to a common bathroom facility from adjoining rooms in hospitals, long term care facilities, schools and dormitories.
• (2) Electrified Locking Devices (Mortise, Cylindrical or ElectroMagnetic)
• (1) 1.5 Amp Power Supply with Universal Relay Module (631RFXUR1)
• (2) Emergency Access Push Button Switches (CB400-B)
• (1) System Activation Push Button Switch (CB400-A)
• (2) Build-in Latch or Door Position Status Sensors (DPS , L)
• (2) Power Transfer Hinges* *(not required for EMLocks) (PTH)
PACKAGE COMPONENTS:
MODELS
CBP-ME-78 includes Eclipse style mortise locks (Z7850LQDE)
CBP-MG-78 includes Galaxy style mortise locks Z7850LQDG)
MORTISE LOCK OPTION:
CB400-A Series
CB400-B Series
WARRANT
Y
YEAR5
CBP-CE-72 includes Eclipse style cylindrical locks (Z7250EQ)
CBP-CG-72 includes Galaxy style cylindrical locks (Z7250GQ)
CYLINDRICAL LOCK OPTION:
CBP-EM-81 includes EMLock locking devices 650lb (1581VD)
CBP-EM-71 includes EMLock locking devices 1200lb (1571VD)
CBP-EM-11 includes EMLock locking devices 1650lb (1511VD)
ELECTRO MAGNETIC OPTION:
Every Shared Bathroom Package also includes a Riser Diagram, Components List, Method of Operation and Wiring Diagram to help you determine the materials and installation costs to complete your project bid.
-
© 2017 SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
Security Door Controls
LIT-CBP COMMUNICATING BATHROOM PACKAGE 08/17
[t] 800.413.8783 ■ 805.494.0622 ■ [f] 866.215.3138 ■ 801 Avenida Acaso, Camarillo, CA 93012 ■ PO Box 3670, Camarillo, CA 93011
APPLICATIONZ7850 x DPS
Electrified Mortise Lock with Door Status
631RFXUR-1 1.5 Amp, 12/24 VDC Class 2 Output Power Supply w/Comm. Bath Control Module
402-B Emergency Release Button
PTH Power Transfer Hinge
1581 x DPS EMLock® 650lb1571 x DPS EMLock® 1200lb1511 x DPS EMLock® 1650lb
Z7250 Electrified Cylindrical Lock with Latch Status
PTH Power Transfer Hinge
402-A System Activation Button
631RFXUR-1 1.5 Amp, 12/24 VDC Class 2 Output Power Supply w/Comm. Bath Control Module
402-B Emergency Release Button
402-A System Activation Button
631RFXUR-1 1.5 Amp, 12/24 VDC Class 2 Output Power Supply w/Comm. Bath Control Module
401-B Emergency Release Button
401-A System Activation Button
-
C NO C NO - NO C NC - NO C NC
- +
TRIG A TRIG B RELAY A RELAY B
w
DA
w
DB
J1
UR-1
PWR
PROJECT NAME:
DIST.: DWG. NO.:DRAWN BY: DATE:LOCATION.: CONTACT:
SO NO.: REVTITLE:-801 Avenida Acaso
Camarillo, CA 93012t 805.494.0622 ~ f 805.494.8861www.sdcsecurity.com
--
--
2-Door Communicating Bath System – Electrified Cylindrical Solution
- [email protected] --06/17 Page 1 of 3
-
© 2017 Security Door Controls Printed in U.S.A
Door 1
Door 2
EMERGENCYRELEASE
PUSHTO UNLOCK DOOR
CB402-B(OUTSIDE DOOR 2)
CB402-A
ACTIVATIONBUTTONSWITCH(INSIDE)
C
N/CN/O
YEL
WHT
C
N/CN/O
YEL
WHT
BATHROOM LOCKBOTH DOORS MUST BE
CLOSED TO LOCK
LIGHT ON DOOR LOCKED
PUSH TO LOCK
EMERGENCYRELEASE
PUSHTO UNLOCK DOOR
CB402-B(OUTSIDE DOOR 1)
C
N/CN/OYEL
WHT
RED
RED
LAMPRED
RED
LAMP
ROCKER SWITCH SETTINGS:SWITCH #1 IS ONALL OTHER SWITCHES OFF
WET/DRY SELECTION JUMPERS:Both “A” & “B” set to WET
WET
DRY
RED
RED
LAMP
Method of Operation:Both doors are normally closed and unlocked.
System Activation: Upon entering the bathroom and closing both doors, momentarily pressing the Activation Button will lock both doors and turn ON the indicator lamps on the Activation and Emergency Release Buttons, indicating the system is active.
System Deactivation:Operating the inside lever to retract the latch on either door will unlock both doors and turn off all indicator lamps. Using a key override from the outside to enter either door will also reset the system and unlock both doors.
Emergency Override:Momentarily pressing either Emergency Release Button located outside each door will immediately unlock both doors and reset the system.
CBP-C Series – System Components:(1) 631RFXUR1 – 1A Power Supply w/ Comm. Bath Controller(1) CB402-A – Activation Button(2) CB402-B – Emergency Release Button(2) Z7250EQ or Z7250GQ – Electrified Cylindrical Lock, Eclipse or Galaxy Lever(2) PTH-4Q – 4.5"x4.5" Power Transfer Hinge
BatteryChargerIndicator Fuse
AC PowerLED
PrimaryFuse 250V1.5Amp
BatteryInput
System StatusLED
G W B
TO 120VAC PRIMARYVOLTAGE CONNECTION
(Remove factory installed jumper only when fire alarm interface is used)
+-
DC Voltage Output
Terminals+ - C
12V
SHORT
OPEN
24V
VOLTAGE SELECT
Note:SET TO 24VDC.
Power must be turned off before changing voltage jumper631RF
NOTE: ALL WIRING MUST BE REVIEWED AND APPROVED BY THE PROJECT ENGINEER ASSIGNED TO THE LOCATION FOR ITS CORRECTNESS AND SUITABILITY FOR THE APPLICATION IN THE WHICH THE EQUIPMENT IS INSTALLED AND OPERATED. ALL WIRING MUST CONFORM TO NATIONAL, STATE, AND LOCAL CODES FOR CLASS 2 FIRE PROTECTION AND CONTROL DEVICES.
22/4C
ACMains
(3) COND
18/4C
22/4C
18/4C
Z7250EQ/GQElectrified Cylindrical Lock
(Fail-Safe)
Z7250EQ/GQElectrified Cylindrical Lock
(Fail-Safe)
631RFPowerSupplyx UR-1
PTH-4QPower
TransferHinge
PTH-4QPower
TransferHinge
CB402-AActivation
Button
CB402-BEmergency
Release(Outside)
CB402-BEmergency
Release(Outside)
Door #1 Door #2
22/4C
-
C NO C NO - NO C NC - NO C NC
- +
TRIG A TRIG B RELAY A RELAY B
w
DA
w
DB
J1
UR-1
PWR
PROJECT NAME:
DIST.: DWG. NO.:DRAWN BY: DATE:LOCATION.: CONTACT:
SO NO.: REVTITLE:-801 Avenida Acaso
Camarillo, CA 93012t 805.494.0622 ~ f 805.494.8861www.sdcsecurity.com
--
--
2-Door Communicating Bath System – Electrified Mortise Solution
- [email protected] --06/17 Page 2 of 3
-
© 2017 Security Door Controls Printed in U.S.A
Door 1
Door 2
EMERGENCYRELEASE
PUSHTO UNLOCK DOOR
CB402-B(OUTSIDE DOOR 2)
CB402-A
ACTIVATIONBUTTONSWITCH(INSIDE)
C
N/CN/O
YEL
WHT
C
N/CN/O
YEL
WHT
BATHROOM LOCKBOTH DOORS MUST BE
CLOSED TO LOCK
LIGHT ON DOOR LOCKED
PUSH TO LOCK
EMERGENCYRELEASE
PUSHTO UNLOCK DOOR
CB402-B(OUTSIDE DOOR 1)
C
N/CN/OYEL
WHT
RED
RED
LAMPRED
RED
LAMP
ROCKER SWITCH SETTINGS:SWITCH #1 IS ONALL OTHER SWITCHES OFF
WET/DRY SELECTION JUMPERS:Both “A” & “B” set to WET
WET
DRY
RED
RED
LAMP
Method of Operation:Both doors are normally closed and unlocked.
System Activation: Upon entering the bathroom and closing both doors, momentarily pressing the Activation Button will lock both doors and turn ON the indicator lamps on the Activation and Emergency Release Buttons, indicating the system is active.
System Deactivation:Operating the inside lever & opening either door will unlock both doors and turn off all indicator lamps. Using a key override from the outside to enter either door will also reset the system and unlock both doors.
Emergency Override:Momentarily pressing either Emergency Release Button located outside each door will immediately unlock both doors and reset the system.
CBP-M Series – System Components:(1) 631RFXUR1 – 1A Power Supply w/ Comm. Bath Controller(1) CB402-A – Activation Button(2) CB402-B – Emergency Release Button(2) Z7850LQDE or Z7850LQDG –Electrified Mortise Lock w/ DPS, Eclipse or Galaxy Lever(2) PTH-4Q – 4.5"x4.5" Power Transfer Hinge
BatteryChargerIndicator Fuse
AC PowerLED
PrimaryFuse 250V1.5Amp
BatteryInput
System StatusLED
G W B
TO 120VAC PRIMARYVOLTAGE CONNECTION
(Remove factory installed jumper only when fire alarm interface is used)
+-
DC Voltage Output
Terminals+ - C
12V
SHORT
OPEN
24V
VOLTAGE SELECT
Note:SET TO 24VDC.
Power must be turned off before changing voltage jumper631RF
NOTE: ALL WIRING MUST BE REVIEWED AND APPROVED BY THE PROJECT ENGINEER ASSIGNED TO THE LOCATION FOR ITS CORRECTNESS AND SUITABILITY FOR THE APPLICATION IN THE WHICH THE EQUIPMENT IS INSTALLED AND OPERATED. ALL WIRING MUST CONFORM TO NATIONAL, STATE, AND LOCAL CODES FOR CLASS 2 FIRE PROTECTION AND CONTROL DEVICES.
PTH-4Q4-Wire Power
Transfer Hinge
RedBlk
Wht
Grn
Z7850 SeriesFail-safe Electrified Lockset
(24VDC configuration shown)
BLK
BLU
RED(+)
WHT(+)
SDC P/N: Z7850LQDG or
Z7850LQDE
MOV*
WHT (26AWG)
YEL
*Install MOV across coil to protect UR-1 electronics. MOV included with UR-1.
22/4C
ACMains
(3) COND
18/4C
22/4C
18/4C
Z7850 SeriesElectrified Mortise Lock
(Fail-Safe)
Z7850 SeriesElectrified Cylindrical Lock
(Fail-Safe)
631RFPowerSupplyx UR-1
PTH-4QPower
TransferHinge
PTH-4QPower
TransferHinge
CB402-AActivation
Button
CB402-BEmergency
Release(Outside)
CB402-BEmergency
Release(Outside)
Door #1 Door #2
22/4C
PTH-4Q4-Wire PowerTransfer Hinge
RedBlk
Wht
Grn
Z7850 SeriesFail-safe Electrified Lockset
(24VDC configuration shown)
BLK
BLU
RED(+)
WHT(+)
SDC P/N: Z7850LQDG or
Z7850LQDE
MOV*
WHT (26AWG)
YEL
*Install MOV across coil to protect UR-1 electronics. MOV included with UR-1.
-
C NO C NO - NO C NC - NO C NC
- +
TRIG A TRIG B RELAY A RELAY B
w
DA
w
DB
J1
UR-1
PWR
PROJECT NAME:
DIST.: DWG. NO.:DRAWN BY: DATE:LOCATION.: CONTACT:
SO NO.: REVTITLE:-801 Avenida Acaso
Camarillo, CA 93012t 805.494.0622 ~ f 805.494.8861www.sdcsecurity.com
--
--
2-Door Communicating Bath System – Electromagnetic Lock Solution
- [email protected] --06/17 Page 3 of 3
-
© 2017 Security Door Controls Printed in U.S.A
Door 1
Door 2
EMERGENCYRELEASE
PUSHTO UNLOCK DOOR
CB401-B(OUTSIDE DOOR 2)
CB401-A
ACTIVATIONBUTTONSWITCH(INSIDE)
C
N/CN/O
YEL
WHT
C
N/CN/O
YEL
WHT
BATHROOM LOCKBOTH DOORS MUST BE
CLOSED TO LOCK
LIGHT ON DOOR LOCKED
PUSH TOLOCK OR UNLOCK
EMERGENCYRELEASE
PUSHTO UNLOCK DOOR
CB401-B(OUTSIDE DOOR 1)
C
N/CN/OYEL
WHT
RED
RED
LAMPRED
RED
LAMP
WET/DRY SELECTION JUMPERS:Both “A” & “B” set to WET
WET
DRY
RED
RED
LAMP
BatteryChargerIndicator Fuse
AC PowerLED
PrimaryFuse 250V1.5Amp
BatteryInput
System StatusLED
G W B
TO 120VAC PRIMARYVOLTAGE CONNECTION
(Remove factory installed jumper only when fire alarm interface is used)
+-
DC Voltage Output
Terminals+ - C
12V
SHORT
OPEN
24V
VOLTAGE SELECT
Note:SET TO 24VDC.
Power must be turned off before changing voltage jumper631RF
NOTE: ALL WIRING MUST BE REVIEWED AND APPROVED BY THE PROJECT ENGINEER ASSIGNED TO THE LOCATION FOR ITS CORRECTNESS AND SUITABILITY FOR THE APPLICATION IN THE WHICH THE EQUIPMENT IS INSTALLED AND OPERATED. ALL WIRING MUST CONFORM TO NATIONAL, STATE, AND LOCAL CODES FOR CLASS 2 FIRE PROTECTION AND CONTROL DEVICES.
ROCKER SWITCH SETTINGS:ALL SWITCHES OFF
LOCK PWR
1581VD
DPS}
LOCK PWR
1581VD
DPS}
Method of Operation:Both doors are normally closed and unlocked.
System Activation: Upon entering the bathroom and closing both doors, pressing the Activation Button once will lock both doors and turn ON the indicator lamps on the Activation and Emergency Release Buttons indicating the system is active.
System Deactivation:Pressing the Activation Button a second time will unlock both doors and turn off all button indicator lamps.
Emergency Override:When the doors are locked, pressing either Emergency Release Button located outside each door will immediately unlock its respective door and turn OFF its indicator lamp. During an Emergency Override, pressing the same Emergency Release Button a second time will return the system to normal operation.
CBP-EM Series – System Components:(1) 631RFXUR1 – 1A Power Supply w/ Comm. Bath Controller(1) CB401-A – Activation Button(2) CB401-B – Emergency Release ButtonChoose an EMLock® Option:(2) 1581VD – 650lb EMLock® w/ DPSOR(2) 1571VD – 1200lb EMLock® w/ DPSOr(2) 1511VD – 1650lb EMLock® w/ DPS
22/4C
ACMains
(3) COND
18/4C22/4C18/4C
1500 SeriesElectromagnetic Lock
(Fail-Safe)
631RFPowerSupplyx UR-1
CB401-AActivation
Button(Inside)
CB401-BEmergency
Release(Outside)
CB401-BEmergency
Release(Outside)
Door #1 Door #2
22/4C
1500 SeriesElectromagnetic Lock
(Fail-Safe)
PWR
DPS
{CLOSEDCOM
{
BA
1571VD/11VD
34
56
78
PWR
DPS
{CLOSEDCOM
{
BA
1571VD/11VD
34
56
78
CLOSEDCOM
CLOSEDCOM