01 Copertina Pulsar - AIRCO lineel]file.pdf · NO: components are not interchangeable. 3.1.1 Note...

14
SPARE PARTS LIST - November 2005 - PULSAR

Transcript of 01 Copertina Pulsar - AIRCO lineel]file.pdf · NO: components are not interchangeable. 3.1.1 Note...

Page 1: 01 Copertina Pulsar - AIRCO lineel]file.pdf · NO: components are not interchangeable. 3.1.1 Note Every model of boiler is available in the version working with Natural Gas or in

SPARE PARTS LIST - November 2005 -

PULSAR

Page 2: 01 Copertina Pulsar - AIRCO lineel]file.pdf · NO: components are not interchangeable. 3.1.1 Note Every model of boiler is available in the version working with Natural Gas or in
Page 3: 01 Copertina Pulsar - AIRCO lineel]file.pdf · NO: components are not interchangeable. 3.1.1 Note Every model of boiler is available in the version working with Natural Gas or in

WESTEN HOW TO READ THE SPARE PARTS CATALOGUE In the spare part catalogue, after the exploded diagrams, there are the components lists of the boilers; this is the meaning of the different columns: Pos. Identification number of the component in the exploded diagram of the boiler. Description Short description of the component. Code BAXI S.p.A. code of the component. Tab. XX XX is the exploded diagram number of the boiler taken into consideration. From serial number Date (year and week) identifying the beginning of production of a component (taken

from the serial number of the boiler). e.g. B005: year 2000 (B identifies the decade 2000-2009; 0 identifies the year) – 5th week. If the box is empty, the component is in use from the beginning of production of the boiler.

To serial number Date (year and week) identifying the end of production of a component (taken from

the serial number of the boiler). e.g. B012: year 2000 (B identifies the decade 2000-2009; 0 identifies the year) – 12th week.

If the box is empty, the component is still in use. Interchangeable It identifies the interchangeability between the new component and the old one. YES: components are interchangeable. NO: components are not interchangeable.

3.1.1 Note Every model of boiler is available in the version working with Natural Gas or in the version working with LPG. The boiler’s code (composed of a prefix CWB and 9 numbers) identifies the version as follows: 6th number = 1: LPG version 6th number = 3: Natural Gas version

Page 4: 01 Copertina Pulsar - AIRCO lineel]file.pdf · NO: components are not interchangeable. 3.1.1 Note Every model of boiler is available in the version working with Natural Gas or in

30

5

28

4627

692

31

3

35

242

241

2845

29

2

167168 166

151

154693

137

140

192

511

525

135

32

C

34

192

138423 525

C

290140

137

138

99

98

102

113

21

421

169

C

340

147

192

136

73

72

3387

33

80496

9274

91

517

511

70

33

152

174

174

174

43 44

314

61

63

63

61

59

41 4

162

. .
TAB.01 PULSAR 1.140 i
Page 5: 01 Copertina Pulsar - AIRCO lineel]file.pdf · NO: components are not interchangeable. 3.1.1 Note Every model of boiler is available in the version working with Natural Gas or in

62

62

1213

13231

49

22

25

15

5

9

10

23

2846

27

63

61

314

692

59

61

63

18

3

35

82845

29

47

2

32

167168

166

151

154

12

13534

24

683

683511

99

98

102

113

21

421

169

340

192

136

C

73

72

3387

33

80496

92

74

91

517

511

70

33

137

192

192

147

152

174

174

174

43 44

137

140

192

525

C

192

138423 525

C

290140

137

138

30 3731

403938

4

162

403938

41

. .
Tab. 02 PULSAR 1.140 Fi
Page 6: 01 Copertina Pulsar - AIRCO lineel]file.pdf · NO: components are not interchangeable. 3.1.1 Note Every model of boiler is available in the version working with Natural Gas or in

30

5

28

46

43

27

41

692

63

61

314 59

61

63

31

3

35

242

241

2845

29

2

44

167168 166

151

154693

137

140

192

511

525

135

32

ttTAB 03 PULSAR 1.240 i cube 1.240i

C

34

192

138423 525

C

290140

137

138

99

98

102

113

21

421

169

C

340

147

192

136

73

72

3387

33

80496

9274

91

517

511

70

33

152

174

174

174

4

162

Page 7: 01 Copertina Pulsar - AIRCO lineel]file.pdf · NO: components are not interchangeable. 3.1.1 Note Every model of boiler is available in the version working with Natural Gas or in

30

62

62

1213

13231

37

49

22

25

15

5

9

10

23

2846

43

27

41

63

61

314

692

59

61

63

31

18

3

35

82845

29

47

2

32

44

167168

166

151

154

12

135

525

140C

34

24

TAB 04 PULSAR 1.240 FiEco cube 1.240Fi

683

683511

99

98

102

113

21

421

169

340

192

136

C

73

72

3387

33

80496

92

74

91

517

511

70

33

137

192

192

147

152

174

174

174

4

162

403938

Page 8: 01 Copertina Pulsar - AIRCO lineel]file.pdf · NO: components are not interchangeable. 3.1.1 Note Every model of boiler is available in the version working with Natural Gas or in

169

138423 525

30

5

28

46

43

27

41

692

63

61

314 59

61

63

31

3

35

242

241

2845

29

2

44

167168 166

151154

693

B

A

336

337

9274

80

624

72

77

73

91

3387

33

132131

340

147

421

98

76

421

99

99

192

137

140

192

511

517 70

33

511

136

C

525

C

A

113

119

510

120

118114

102

B

81

122

498

280

493

90

496

135

32

TAB. 05 PULSAR 240 i 3 ATM

C

290

34

140 192

137

138

152

174

174

174

4

162

Page 9: 01 Copertina Pulsar - AIRCO lineel]file.pdf · NO: components are not interchangeable. 3.1.1 Note Every model of boiler is available in the version working with Natural Gas or in

169

147

C

152

174

174

174

4

162

30

62

62

1213

13231

37

49

22

25

15

5

9

10

23

2846

43

27

41

63

61

314

692

59

61

63

31

18

3

35

82845

29

47

2

32

44

167168

166

151

154

12

B

A

336

337

9274

80

624

72

77

73

91

3387

33

132131

340

421

98

76

421

99

99

192

137

192

192

683683 511

517

70

33

511

136

135

525

140C

A

113

119

510

120

118114

102

B

81

122

498

280

493

90

496

34

24

ETAB. 06 PULSAR 240 Fico3 FF

403938

Page 10: 01 Copertina Pulsar - AIRCO lineel]file.pdf · NO: components are not interchangeable. 3.1.1 Note Every model of boiler is available in the version working with Natural Gas or in

PULSAR

1/11/05 CYH44

1143

980 -

PULS

AR 1.

140i

CYH44

5143

980 -

PULS

AR 1.

140 F

i

CYH44

1243

980 -

PULS

AR 1.

240i

CYH44

5243

980 -

PULS

AR 1.

240 F

i

CYH44

2243

980 -

PULS

AR 24

0i

CYH44

6243

980 -

PULS

AR 24

0 Fi

Pos Description CodeTab.01

Tab.02

Tab.03

Tab.04

Tab.05

Tab.06

From serial number

To serial number

Inter-changeable

Note

2 LEFT PANEL ASSEMBLY 5668310 l l B524 NO2 LEFT PANEL ASSEMBLY 5677560 l l l B5252 LEFT PANEL ASSEMBLY 5663680 l l B524 NO2 LEFT PANEL ASSEMBLY 5677580 l l l B5253 RIGH PANEL ASSEMBLY 5668300 l l B524 NO3 RIGH PANEL ASSEMBLY 5677550 l l l B5253 RIGH PANEL ASSEMBLY 5663670 l l B524 NO3 RIGH PANEL ASSEMBLY 5677570 l l l B5254 ECO CUBE FRONTAL PANEL 5115470 l l l l B524 NO4 ECO CUBE FRONTAL PANEL 5115620 l l l l l l B5255 FRONTAL TRAVERSE 5113790 l l l l l l

8 AIR PRESSURE SWITCH PIPE L=270 5408080 l l l

9 SUCTION RESTRICTOR D.80 5108700 l l l

10 COAXIAL FLUE GASKET 5409450 l l l

12 SUCTION CAP 5108690 l l l

13 SUCTION CAP GASKET 5407400 l l l

15 JOINT ASSEMBLY D. 100 L=20 (with screws) 5664050 l l l

18 FLUE PLASTIC VENTURI 5409580 l l l

21 GASKET 6,1X12X1,5 WRC 5402050 l l l l l l

22 FAN 1 SPEED 5663810 l l l

23 FAN PRESSURE SWITCH 5640000 l l l

24 COMPENSATION PIPE L=130 5407930 l l l

25 CONVEYOR 5113800 l l l

27 COMBUSTION CHAMBER ASSEMBLY 5676830 l l

27 COMBUSTION CHAMBER ASSEMBLY 5677210 l l

27 COMBUSTION CHAMBER ASSEMBLY 5677940 l

27 COMBUSTION CHAMBER ASSEMBLY 5678490 l

28 LATERAL INSULATING PANEL 5213210 l l l

28 LATERAL INSULATING PANEL 5213220 l l l

29 REAR INSULATING PANEL 5213280 l l l l l l

30 FRONTAL INSULATING PANEL (FF) 5213370 l l l

30 FRONTAL INSULATING PANEL (FF) 5213380 l l l

31 COMB. CHAMBER PANEL 5113820 l l l

31 COMB. CHAMBER PANEL 5114290 l l l

32 PRIMARY EXCHANGER WITH CLIPS 5677660 l l l l l l

33 O-RING 22X3 EPDM 5403130 l l l l l l

34 CLIPS FOR PRIMARY EXCHANGER 5113650 l l l l l l

35 EXPANSION VESSEL 8L 5663880 l l l

35 EXPANSION VESSEL 7L 5668370 l l l

37 SEALED CHAMBER FRONT PANEL 5663830 l l l

38 PILOT SIGHT GLASS GASKET 5401610 l l l

39 PILOT SIGHT GLASS 5203930 l l l

40 PILOT SIGHT FRAME 5103360 l l l

41 BURNER ASSEMBLY (13 ELEMENTS) 5663710 l l l l

41 BURNER ASSEMBLY (10 ELEMENTS) 5665980 l l

43 GAS RAMP WITH INJECTORS (N.G. D.1,28) 612960 l l

43 GAS RAMP WITH INJECTORS (N.G. D.1,18) 615260 l l

Page 11: 01 Copertina Pulsar - AIRCO lineel]file.pdf · NO: components are not interchangeable. 3.1.1 Note Every model of boiler is available in the version working with Natural Gas or in

PULSAR

1/11/05 CYH44

1143

980 -

PULS

AR 1.

140i

CYH44

5143

980 -

PULS

AR 1.

140 F

i

CYH44

1243

980 -

PULS

AR 1.

240i

CYH44

5243

980 -

PULS

AR 1.

240 F

i

CYH44

2243

980 -

PULS

AR 24

0i

CYH44

6243

980 -

PULS

AR 24

0 Fi

Pos Description CodeTab.01

Tab.02

Tab.03

Tab.04

Tab.05

Tab.06

From serial number

To serial number

Inter-changeable

Note

43 GAS RAMP WITH INJECTORS (N.G. D.1,18) 619610 l l

44 NATURAL GAS INJECTORS KIT 5666400 l l

44 NATURAL GAS INJECTORS KIT 5669460 l l l l

44 LPG INJECTORS KIT 5680020 l l l l l l

45 GAS RAMP GASKET 5407940 l l l l l l

46 GAS RAMP CONNECTING FLANGE 5211030 l l l l l l

47 GASKET (GAS RAMP/SEALED CHAMBER) 5404760 l l l

49 HOSE ADAPTER CAP 5409520 l l l

59 IGNITION ELECTRODE CABLE 8419050 l l l l l l

61 ELECTRODE PROTECTION CAP 5407830 l l l l l l

62 SEALED CHAMBER HOSE ADAPTER 5409570 l l l

63 IGNITION ELECTRODE 8422570 l l l l l l

70 PIPE ASSEMBLY (PUMP/EXCHANGER) 5676860 l l l

70 PIPE ASSEMBLY (PUMP/EXCHANGER) 5677270 l l l

72 PUMP UP 15-50 AO (GRUNDFOS) 5661200 l l l l l l

73 AIR VENT VALVE WITH O-RING (CALEFFI) 607290 l l l l l l

74 OR 14X1,78 EP 5406360 l l l l l l

76 HEAT EXCHANGER-DHW(10 PLATES) ALFA LAVAL 5653650 l l

77 GASKET-PLATE HEAT EXCHANGER 5404520 l l

80 HYDRAULIC INLET GROUP 5676890 l l

80 HYDRAULIC INLET ASSEMBLY 5655650 l l l l

81 FILTER VENTURI AND PADDLE ASSEMBLY 619050 l l

87 PUMP CONNECTING ELEMENT 5210710 l l

90 FILLING TAP ASSEMBLY 611930 l l

91 DRAINING TAP 5652030 l l l l l l

92 HYDRAULIC SAFETY VALVE WITH O.R. -3 bar- 5653690 l l l l l l

98 BY-PASS PIPE ASSEMBLY 5212890 l l

98 BY-PASS PIPE ASSEMBLY 5672770 l l l l

99 CLIP - FIXING - BYPASS 8380850 l l l l l l

102 3 WAY VALVE ASSEMBLY 5676910 l l

102 CH OUTLET - ASSEMBLY 5676490 l l l l

113 HYDRAULIC OUTLET / BY-PASS ASSEMBLY 617100 l l l l l l

114 O-RING 26,64x2,62 EP -50- 5403820 l l

118 CONIC SPRING 8380520 l l

119 HEATING PLATE ASSEMBLY 605760 l l

120 SANITARY PLUG ASSEMBLY 600750 l l l l l l

122 O-RING 23,47X2,62 E.P. -49- 5405370 l l

131 NTC SENSOR 8434820 l l

132 NTC SENSOR GASKET 5402830 l l l l l l

135 LIMIT THERMOSTAT 105°C 9951610 l l l l l l

136 PIPE ASSEMBLY (3 WAY VALVE/EXCHANGER) 5676870 l l l

136 PIPE ASSEMBLY (3 WAY VALVE/EXCHANGER) 5677260 l l l

137 GAS PIPE - FF (SIT) 5676970 l l l

137 GAS PIPE - ATM (SIT) 5677010 l l l

137 GAS PIPE - FF (HONEYWELL) 5676930 l l l

137 GAS PIPE - ATM (HONEYWELL) 5677250 l l l

138 O-RING 22,22X2,62 5402010 l l l l l l

Page 12: 01 Copertina Pulsar - AIRCO lineel]file.pdf · NO: components are not interchangeable. 3.1.1 Note Every model of boiler is available in the version working with Natural Gas or in

PULSAR

1/11/05 CYH44

1143

980 -

PULS

AR 1.

140i

CYH44

5143

980 -

PULS

AR 1.

140 F

i

CYH44

1243

980 -

PULS

AR 1.

240i

CYH44

5243

980 -

PULS

AR 1.

240 F

i

CYH44

2243

980 -

PULS

AR 24

0i

CYH44

6243

980 -

PULS

AR 24

0 Fi

Pos Description CodeTab.01

Tab.02

Tab.03

Tab.04

Tab.05

Tab.06

From serial number

To serial number

Inter-changeable

Note

140 GAS VALVE (SIT 845063 SIGMA) 5658830 l l l l l l

140 GAS VALVE (HONEYWELL VK4105M 5033) 5665220 l l l l l l

147 CONNECTION TRAVERSE 5676130 l l l l l l

151 ELECTRIC BOX REAR COVER 5409550 l l l l l l

152 PRINTED CONTROL PANEL 5676950 l l l l l l

154 P.C.B. (BERTELLI) 5676960 l l l l l l B541 YES154 P.C.B. (BERTELLI) WITH INSTRUCTION 5680230 l l l l l l B542162 PANEL PLATE - PULSAR 240 Fi 5677540 l

162 PANEL PLATE - PULSAR 240 i 5677690 l

162 PANEL PLATE - PULSAR 1.240 Fi 5677820 l

162 PANEL PLATE - PULSAR 1.240 i 5677830 l

162 PANEL PLATE - PULSAR 1.140 Fi 5678660 l

162 PANEL PLATE - PULSAR 1.140 i 5678660 l

166 TERMINAL BLOCK 8421590 l l l l l l

167 FUSE HOLDER 5405340 l l l l l l

168 FUSE (2A-250V) 9950580 l l l l l l

169 MANOMETER D.40 -T&G 9951330 l l l l l l

174 KNOB 5409750 l l l l l l

192 GASKET G 3/4 17X24X2 WRC 5404650 l l l l l l

231 FLUE INTAKE 5409480 l l l

241 DRAUGHT DIVERTER ASSEMBLY 5668420 l l

241 DRAUGHT DIVERTER ASSEMBLY 5678060 l

242 FLUE SAFETY THERMOSTAT 70°C 616160 l l

242 FLUE SAFETY THERMOSTAT 60°C 606930 l

280 GASKET 14,2X18X1,5 AL -18- 5207730 l l

290 MODULATOR ASSEMBLY -VK4105M- 5665230 l l l l

314 FLAME SENSING ELECTRODE CABLE 8418870 l l l l l l

336 MOTOR FIXING SPRING 8380680 l l

337 ELBI MOTOR 5647340 l l

340 SAFETY CH PRESSURE SWITCH 5663750 l l l l l l

421 O-RING 11,91X2,62 NBR 5408270 l l l l l l

423 GAS VALVE CONNECTION 5210410 l l l l

493 KNOB ASSEMBLY 612130 l l

496 O-RING 2062 400020 l l

498 O-RING 2056 400030 l l

510 DHW PADDLE ASSEMBLY 600760 l l l l l l

511 O-RING 17,86X2,62 5404600 l l l l l l

517 NTC SENSOR (ITS) 8435360 l l l l l l

525 SAC CONNECTOR 8511800 l l l l l l

525 ANSTOSS CONNECTOR 8511790 l l l l l l

624 HALL EFFECT SENSOR 8435280 l l

683 GASKET (PIPE/SEALED CHAMBER) 5408810 l l l

692 PRIMARY EXCHANGER CLIPS 5114360 l l l l l l

693 PRINTED CONTROL PANEL PROTECTION 5114350 l l l

9999 POWER SUPPLY WIRING 8511770 l

9999 POWER SUPPLY WIRING 8511880 l l l

9999 LOW VOLTAGE COMP. WIRING 8511780 l

Page 13: 01 Copertina Pulsar - AIRCO lineel]file.pdf · NO: components are not interchangeable. 3.1.1 Note Every model of boiler is available in the version working with Natural Gas or in

PULSAR

1/11/05 CYH44

1143

980 -

PULS

AR 1.

140i

CYH44

5143

980 -

PULS

AR 1.

140 F

i

CYH44

1243

980 -

PULS

AR 1.

240i

CYH44

5243

980 -

PULS

AR 1.

240 F

i

CYH44

2243

980 -

PULS

AR 24

0i

CYH44

6243

980 -

PULS

AR 24

0 Fi

Pos Description CodeTab.01

Tab.02

Tab.03

Tab.04

Tab.05

Tab.06

From serial number

To serial number

Inter-changeable

Note

9999 LOW VOLTAGE COMP. WIRING 8511940 l l

9999 LOW VOLTAGE COMP. WIRING 8511850 l

9999 LOW VOLTAGE COMP. WIRING 8511910 l l

9999 EARTH WIRING - SIT 8419080 l l l l l l

9999 TIMER CONNECTOR 8418860 l l l l l l

9999 3 WAY VALVE WIRING 8511810 l l

9999 3 WAY VALVE WIRING 8512140 l l l l

9999 PUMP/FUN WIRING 8511820 l l l

9999 MODULATOR/NTC SANITARY SENSOR WIRING 8511830 l

9999 MODULATOR/NTC SANITARY SENSOR WIRING 8511950 l l

9999 MODULATOR WIRING 8511920 l l

9999 NTC HEAT. SENSOR/AIR PRESSURE SWITCH/LIMIT TH. WIRING 8511840 l

9999 NTC HEAT. SENSOR/AIR PRESSURE SWITCH/LIMIT TH. WIRING 8511960 l l

9999 NTC HEAT. SENSOR/H2O PRESS./AIR TH./LIMIT TH. WIRING 8511930 l l

9999 POWER SUPPLY CABLE 8414620 l l l l l l

Page 14: 01 Copertina Pulsar - AIRCO lineel]file.pdf · NO: components are not interchangeable. 3.1.1 Note Every model of boiler is available in the version working with Natural Gas or in

Via Trozzetti, 20 36061 BASSANO DEL GRAPPA (VI) ITALY Tel. +390424517111 Telefax +390424517379