01 - Commercial Building Products€¦ · 16. metal fastener 17. concrete fastener 9. v-line 4”...

15
01 AL13 v-line general installation guide TM Vol 1 TM AL13 architectural system www.al13.com Version 1 pantented product

Transcript of 01 - Commercial Building Products€¦ · 16. metal fastener 17. concrete fastener 9. v-line 4”...

Page 1: 01 - Commercial Building Products€¦ · 16. metal fastener 17. concrete fastener 9. v-line 4” plank 10. v-line 6” plank 11. 4” perforated vent Strip system parts 014 1. end

01AL13v-line generalinstallationguide

TM

Vol 1

TM

AL13architecturalsystem

www.al13.com

Version 1

pantented product

Page 2: 01 - Commercial Building Products€¦ · 16. metal fastener 17. concrete fastener 9. v-line 4” plank 10. v-line 6” plank 11. 4” perforated vent Strip system parts 014 1. end

CLAD THE WORLD

TM

Page 3: 01 - Commercial Building Products€¦ · 16. metal fastener 17. concrete fastener 9. v-line 4” plank 10. v-line 6” plank 11. 4” perforated vent Strip system parts 014 1. end

How to Installv-line

01

TM

AL13architecturalsystem

MEMBRANE

SHEATHING STRUCTURAL FRAMING

V-LINE PLANK

SYSTEM CLIP

or

NOTES

The first part of the installation guide

will outline a basic install on a flat wall

as illustrated above in its completed

form. The subsequent drawings

section will outline more intricate

details like inside corners, outside

corners, windows, doors, overhangs,

and build-outs. (Please ensure to have

read the General Install section first.)

Page 4: 01 - Commercial Building Products€¦ · 16. metal fastener 17. concrete fastener 9. v-line 4” plank 10. v-line 6” plank 11. 4” perforated vent Strip system parts 014 1. end

Installation Guidelines 1

IMPORTANT: Failure to follow the guidelines herein will void the AL13 warranty.

Key steps for a successful installation

Key steps for a successful installation

01

Please read and understand the entirety of this guide. Any questions or inconsistencies should be directed to [email protected]

Guidelines may vary depending on project particulars and conditions. Contact AL13™ with

questions regarding variance from this guide. Standard carpentry skills are required for optimum results.

Good health and safety practices must be followed when installing AL13™ ACM System.

01 Understand the various elements of the system.

02 Plan the installation, work schedule, layout, and material usage.

03 Ensure everyone working has read the installation guidelines.

04 Execute work in the sequence set forth in the installation guidelines.

05 Protection should be worn at all times; gloves, ear protection, safety glasses and hard hat.

06 Protect the product by storing the material in a dry and clean environment.

07 Ensure proper fit of the system.

08 Upon completion of installation, clean any debris on wall.

When materials arrive on site, ensure that all panels, extrusions, and other components are in good condition . All material

should be free of any defects.

> Shipping or packaging issues should be noted on the waybill and then reported to the distributor.

> Should any products be damaged, the receiving party is responsible for filing a freight claim to the shipping company

within 24 hours of receiving product.

> Defective materials should be reported to the distributor from which the product was dispatched from.

Page 5: 01 - Commercial Building Products€¦ · 16. metal fastener 17. concrete fastener 9. v-line 4” plank 10. v-line 6” plank 11. 4” perforated vent Strip system parts 014 1. end

InstallationGuidelines 2

02

TM

AL13architecturalsystem

system parts

014

1. end frame

2. inside corner

3. outside corner

7. perimeter reveal cap assembly

5. perimeter �at cap assembly

6. reveal cap assembly

4. �at cap assembly

8. system clip

12. 10”80T non ferrous saw blade

13. 1/4” 60T non ferrous saw blade

14. gloves

15. metal/wood fastener

16. metal fastener

17. concrete fastener

9. v-line 4” plank

10. v-line 6” plank

11. 4” perforated vent Strip

system parts

014

1. end frame

2. inside corner

3. outside corner

7. perimeter reveal cap assembly

5. perimeter �at cap assembly

6. reveal cap assembly

4. �at cap assembly

8. system clip

12. 10”80T non ferrous saw blade

13. 1/4” 60T non ferrous saw blade

14. gloves

15. metal/wood fastener

16. metal fastener

17. concrete fastener

9. v-line 4” plank

10. v-line 6” plank

11. 4” perforated vent Strip

Product Legend: This installation guide will discuss various components of the system and use component reference blocks.

Please refer to the following to verify the correct component.

Page 6: 01 - Commercial Building Products€¦ · 16. metal fastener 17. concrete fastener 9. v-line 4” plank 10. v-line 6” plank 11. 4” perforated vent Strip system parts 014 1. end

Installation Guidelines 3

Inventory

Tools

01

Once material is verified to be in good condition, take inventory of units according to the packing slip. Make sure all

materials - panel, extrusions, panel spacers, fasteners, and adhesive tape - and quantities are present.

- The distributor should be notified immediately if the order has any missing or incomplete components. Failure to do

so may void re-fulfillment.

AL13™ is made to be installed with general tools. A recommended tool list is as follows:

> Sawhorses/work table

> Circular saw, handheld with guide

> Table saw

> Cordless electric impact with

appropriate bits

> Non-ferrous saw blades intended

for cutting Aluminum

> Mitre saw

> Jigsaw

> Level/plumb line

> Chalk line

> Cordless electric drill

> Drill bit set

> AL13 SLED

Page 7: 01 - Commercial Building Products€¦ · 16. metal fastener 17. concrete fastener 9. v-line 4” plank 10. v-line 6” plank 11. 4” perforated vent Strip system parts 014 1. end

v-lineInstall 1

Fasten vertical perimeter extrusions

fastener24” max spacing

The vertical perimeter extrusions are normally the first extrusions to be fixed to

the wall. The building wrap/envelope must be complete to spec before anything

goes on the wall. Layout end frame extrusions according to the desired location.

Ensure frames are level and plumb before fastening. Consult the fastener speci-

fications guide in this binder to determine fastener type and spacing.

Work flow is always from the bottom up. Place the first fastener near the bottom

of the vertical extrusion. Once the piece has been leveled, add a second near

the top fixing it in place. Add subsequent fasteners according to the fastener

guide spacing. An outside corner frame, inside corner frame, or a perimeter

frame assembly may be used in place of the end frame for vertical applications.

The end frame is shown here only to keep the scope of this guide relatively

simple.

01

Page 8: 01 - Commercial Building Products€¦ · 16. metal fastener 17. concrete fastener 9. v-line 4” plank 10. v-line 6” plank 11. 4” perforated vent Strip system parts 014 1. end

v-lineInstall 2

Fasten horizontal baseline extrusions

fastenermin 2 per back plate

16” on centre

This will establish the horizontal datum - and will be a reference to subsequent

extrusions - so it is important that it is mounted level. Consult the fastener speci-

fication guidelines to establish fastener type and spacing.

The method of install will vary from the vertical components as the horizontal

baseline back plates will need to be segmented to keep a functioning rain

screen through the system. To function as a rain screen you need to follow the

20/80 rule. At any cross section only 20% of the horizontal plane may have and

extrusion attached, and 80% of the horizontal cross section need to be open. To

make it easy pre-cut, and pre-drill all back plate components at 3.2” (81mm) and

install them at every 16” on center.

01

Page 9: 01 - Commercial Building Products€¦ · 16. metal fastener 17. concrete fastener 9. v-line 4” plank 10. v-line 6” plank 11. 4” perforated vent Strip system parts 014 1. end

v-lineInstall 3

Fasten horizontal upper extrusions

fastener24” max spacing

The final perimeter extrusion to be attached is the upper horizontal back plate.

This is the ONLY extrusion that may be used to terminate the system when

running v-line in a horizontal application. The snap lock assembly is crucial to

function, fit and finish.

Unlike the baseline row of segmented back plates, the upper row may be

installed as a solid piece. Leave each end with approx. 3” gap from verticals to

allow for proper top cap installation.

01

Page 10: 01 - Commercial Building Products€¦ · 16. metal fastener 17. concrete fastener 9. v-line 4” plank 10. v-line 6” plank 11. 4” perforated vent Strip system parts 014 1. end

v-lineInstall 4

Engage baseline flat cap

or

The flat cap needs to be cut to size and engaged using an AL13 SLED before

the first row of v-line plank may be installed. A properly fit cap should tuck under

both verticals leaving approx. a 1/8” gap on either side to allow for contraction

and expansion. If a butt joint is required due to the length of the flat cap exceed-

ing 12’, the butt joint MUST occur on a shared back plate segment.

It is only necessary to engage flat cap where the back plate is present. Impact-

ing the flat cap in the voids, between back plates, may cause deformation of the

top cap.

01

Page 11: 01 - Commercial Building Products€¦ · 16. metal fastener 17. concrete fastener 9. v-line 4” plank 10. v-line 6” plank 11. 4” perforated vent Strip system parts 014 1. end

v-lineInstall 5(a)

Installing v-line plank

The v-line board is to be cut to fit between the vertical frame components. A

properly cut to fit plank should have a 1/8” gap from each vertical either side

should be allowing for contraction and expansion.

It is essential the first row of v-line be tucked behind the vertical tab of the frame

components so that the fastening tongue is pointed upwards and the groove is

pointing downwards. The t-tab on the back of the v-line plank should firmly rest

on the feet of the segmented back plate extrusions.

01

Page 12: 01 - Commercial Building Products€¦ · 16. metal fastener 17. concrete fastener 9. v-line 4” plank 10. v-line 6” plank 11. 4” perforated vent Strip system parts 014 1. end

v-lineInstall 5(b)

Installing v-line plank

Once the v-line plank has been fitted and leveled to an even plane, it will be secured by

attaching a AL13 system clip to the upwards pointing tongue. The narrow face of the clip should

be pointing away from the wall. Make sure the clip is fully inserted before adding fastener to the

through-hole. The function of the clip is to secure the plank in place while spacing it from the wall.

The fastener will not penetrate the v-line plank itself. This will allow each v-line plank contract and

expand through the full temperature spectrum. A clip and fastener are to be attached to each

v-line plank once every 32” MAX. A minimum of one system clip is required per v-line plank.

The maximum consecutive run of V-line plank will be 24’ without a vertical brake. (End frame,

flat cap, or reveal cap assembly) If the required v-line length exceeds 12’, butt jointing two planks

together will be required. A single system clip is to be used at the seam of the butt joint to ensure

a precision fit. As we still need to account for contraction and expansion yet require a tight butt

seam. The v line planks must have MAX ¼” gap at each side of the vertical break.

01

Page 13: 01 - Commercial Building Products€¦ · 16. metal fastener 17. concrete fastener 9. v-line 4” plank 10. v-line 6” plank 11. 4” perforated vent Strip system parts 014 1. end

v-lineInstall 6(a)

Installing the final row of v-line plank

The final or top row to be installed will require the v-line plank to be ripped to

width by a table saw to its appropriate dimension. Due to this, the top rows

installation will vary from the regular installation.

The top row does not require the system clip to be held in place with a fastener.

The top row of V-line plank will be held in place by securely engaging the perim-

eter flat cap or reveal cap. A system clip is still used, but it is clipped on to the

perimeter back plate assembly. It functions as a spacer only.

01

Page 14: 01 - Commercial Building Products€¦ · 16. metal fastener 17. concrete fastener 9. v-line 4” plank 10. v-line 6” plank 11. 4” perforated vent Strip system parts 014 1. end

v-lineInstall 6(b)

Installing the final row of v-line plank

intersection

To secure the final row, a perimeter cap must be cut to length to fit behind the

vertical frame extrusions. A proper fit should allow for a 1/8” gap on either side to

allow for contraction and expansion. The perimeter cap should be hammered in

place using an AL13 SLED with a rubber mallet.

01

Page 15: 01 - Commercial Building Products€¦ · 16. metal fastener 17. concrete fastener 9. v-line 4” plank 10. v-line 6” plank 11. 4” perforated vent Strip system parts 014 1. end

CLAD THE WORLD

TM

Vancouver Office Los Angeles Office

Toronto Office Chicago Office

Calgary Office Houston Office

Montreal Office New York Office

[email protected]

778 724 0813

[email protected]

323 486 0111

www.al13.com

[email protected]

647 478 7726

[email protected]

312 424 9905

[email protected]

403 910 2433

[email protected]

713 714 4441

[email protected]

514 316 7160

[email protected]

646 741 7222

01 05

03 07

02 06

04 08

patent product