001

2
OTDR Report Job Info Job ID : umuahia Reason : Contractor : Operator A : Customer : MTNN Operator B : Test Date : 3/3/2009 (2:49:49 PM) File : 001.trc Cable Info Fiber ID : 01 Cable ID : 16smf Location A : nipost Location B : oax37 Cable Mfr. : Type : Subset ID : Color ID : Link Measurements Link Loss : 15.425 dB Avg. Splice Loss : 0.060 dB Link Length : 44.5798 km Max. Splice Loss : 0.333 dB Average Loss : 0.346 dB/km Total ORL : <19.95 dB OTDR Trace 10 20 30 40 50 km 0.00 5.00 10.00 15.00 20.00 25.00 30.00 35.00 40.00 dB 1 2 3 4 5 6 7 8 9 10 1 1 12

description

otdr report

Transcript of 001

Page 1: 001

OTDR Report

Job Info Job ID : umuahia Reason :Contractor : Operator A :Customer : MTNN Operator B :Test Date : 3/3/2009 (2:49:49 PM) File : 001.trc

Cable Info Fiber ID : 01 Cable ID : 16smfLocation A : nipost Location B : oax37Cable Mfr. : Type :Subset ID : Color ID :

Link Measurements Link Loss : 15.425 dB Avg. Splice Loss : 0.060 dBLink Length : 44.5798 km Max. Splice Loss : 0.333 dBAverage Loss : 0.346 dB/km Total ORL : <19.95 dB

OTDR Trace

10 20 30 40 50 km0.00

5.00

10.00

15.00

20.00

25.00

30.00

35.00

40.00

dB

1

2

3

45

67 8

910

11

12

Page 2: 001

OTDR Report

Events Table

No. Loc.(km)

Event Type Loss(dB)

Refl.(dB)

Att.(dB/km)

Cumul.(dB)

1 0.0000 Launch Level - - - >-20.4 0.000Fiber Section (5.5099 km) 1.805 0.328 1.805

2 5.5099 Non-Reflective Fault 0.085 1.890Fiber Section (5.9184 km) 1.951 0.330 3.841

3 11.4283 Non-Reflective Fault 0.034 3.875Fiber Section (5.9848 km) 1.982 0.331 5.857

4 17.4132 Positive Fault -0.096 5.761Fiber Section (3.0230 km) 1.015 0.336 6.776

5 20.4362 Non-Reflective Fault 0.066 6.841Fiber Section (6.0206 km) 2.013 0.334 8.854

6 26.4568 Non-Reflective Fault 0.050 8.904Fiber Section (2.0477 km) 0.724 0.353 9.628

7 28.5045 Non-Reflective Fault 0.073 9.700Fiber Section (1.0468 km) 0.347 0.332 10.048

8 29.5513 Non-Reflective Fault 0.053 10.101Fiber Section (2.9924 km) 1.001 0.334 11.102

9 32.5437 Positive Fault -0.073 11.029Fiber Section (2.9465 km) 0.980 0.333 12.008

10 35.4902 Non-Reflective Fault 0.078 12.087Fiber Section (5.3210 km) 1.740 0.327 13.827

11 40.8112 Non-Reflective Fault 0.333 14.160Fiber Section (3.7686 km) 1.265 0.336 15.425

12 44.5798 Reflective Fault - - - -14.3 15.425

Marker Info A : 0.0000 km, 35.016 dB B : 0.0000 km, 35.016 dBa : N/A b : N/AA to B Distance : 0.0000 km A to B LSA Att. : 0.000 dB/kmA to B LSA Loss : 0.000 dB2-pt. Ev. Loss : 0.000 dB

Test and Cable Setup Wavelength : 1310 nm (SM-9µm) Acq. Time : 15 sFilename : 001.trc Pulse Width : 1.0 µsHardware : FTB-7200D-023B-EI Helix Factor : 0.00 %Serial Number : 388976 Splice Loss Threshold : 0.020 dBSoftware : N/A Reflectance Threshold : -72.0 dBRange : 60.0 km End-of-Fiber Threshold : 5.000 dBIOR : 1.46770RBS : -79.44