Nottingham Royal Concert Hall
Background◦ Project Scope
Replace existing Tungsten light source with LED Retain the existing lighting points Recreate exactly the same lighting feel Compatible with existing DMX control system Seamless dimming to zero Viable ROI
Nottingham Royal Concert Hall
A program of works where the capital cost is recovered through energy savings which are guaranteed by E.ON
£
£
£
£
£
£
£
£
£
Imp
lem
en
tati
on
costs
(in
cl.
fi
nan
cin
g)
Ongoing
savings
Guaranteed savings period
Guaranteed savings
p.a.
Savings in the early
years repay the
initial capital
investment thereby limiting
client risk
Client net
benefit
Energy Performance Contracting
Nottingham Energy Performance Contract • E.ON secured a contract under the RE:FIT Framework
to deliver an EPC for Nottingham City Council.
• £1.2M Investment to deliver a 26% energy saving
across 8 buildings, including Leisure Centres, Care
Homes and a Sports Stadium.
• All savings guaranteed for 7 years in order to pay back
the original investment.
• One of the 8 Buildings is the Royal Concert Hall.
Design Challenges (DES)◦ The issues that needed to be resolved
Sourcing suitable product Existing light fittings
Consistent and effective dimming Control interface The building Emergency Lighting Commissioning
Nottingham Royal Concert Hall
Project Hardware – AlphaLED
Nottingham Royal Concert Hall
◦ High Level Lighting (20m+ Height)
60 x Bespoke fittings created Mechanical Interface
2700 CCT – To match tungsten “feel”
3000Lm 28° Beam For punch and penetration. Replaced 300W R95 lamps
Project Hardware – AlphaLED
Nottingham Royal Concert Hall
◦ Low Level Lighting
458 Down lighters Across 4 levels.
2700 CCT Match tungsten feel 700lm @ 11.5 TCW. Replaced 75W Lamps
AlphaLED Attributes◦ Initial Colour Consistency
1 x 2 step SDCM specification. Consistent wall washing
◦ Colour Consistency Guaranteed No colour shift over life (5 years, 50,000 hrs)
◦ Low Lumen Depreciation L95 50,000 hrs capability
Nottingham Royal Concert Hall
Control Gear◦ DMX Capable – Dim to Zero Light level
EldoLED Powerdrive.
Nottingham Royal Concert Hall
Nottingham Royal Concert Hall• Outcome – Theatre Prospective
• LED/energy saving houselights and dimming, the bottom 10%
• Maintenance and consumable savings (700 bulb changes a year previously)
• Audience reaction to the change
Facts and Figures
Nottingham Royal Concert Hall
Nottingham Royal Concert Hall - Energy Usage
Power (W) Qty Total W Total kW
Existing Fittings / Lamps Removed
300W Par 56 300 60 18000 18
75W R95 75 458 34350 34.35
Total 52.35
New AlphaLED Product Installed
Bespoke Atrium 28 Deg Beam
3000lm CRI80+ 2700K 46.1 60 2766 2.766Atrium with astral bezel
700lm CRI80+ 2700K 11.5 458 5267 5.267
8.033
KW Saving 85% saving 44.317
Facts and Figures◦ The comparison is made assuming the lighting is
used in the same way as the existing lighting.
Nottingham Royal Concert Hall
In Use Energy Consumption kW Hrs / Day No Days Total Kwh
Existing 52.35 14 345 252850.5
New Lighting 8.033 14 345 38799.39
Kwh Saving 214051.11
Use control for further energy savings◦ Tungsten to LED – saves 85% energy
Further energy Savings are possible:◦ LED with DMX allows for various dimming profiles◦ Set 100% for Theatre Customer use◦ Set 65% for cleaning◦ Set 50% at other times
◦ These are examples only
Nottingham Royal Concert Hall
Possible to double the saving
◦ Don’t forget to consider use and control
Nottingham Royal Concert Hall
In Use Energy Consumption kW Hrs / Day No Days Total Kwh
Existing 52.35 14 345 252850.5
New Lighting 100% Level 8.033 4 345 11085.54
New Lighting 65% Level 8.033 5 345 9007.00
New Lighting 50% Level 8.033 5 345 6928.46
Total 14 27021.00
Kwh Saving 225829.50
Additional Saving with dimming profile 187030.11
Original Saving 214051.11
Total saving 401081.22
Conclusions◦ Substantial Energy Savings are possible◦ Light Quality can be matched◦ Day to day maintenance eliminated◦ Further substantial savings with controls◦ Hardware guaranteed 5 years 50,000hrs