Gradient HB
unit :mm
[ Indoor ]
TOKI CORPORATION2F JS Progre., 4-1-23, Heiwajima, Ota-ku, Tokyo 143-0006, Japan Tel.03-5763-6121 Fax.03-5763-6130 http://www.toki.co.jp/tokistar/ 2016.9.14
6/6 1/6
・ Please verify if the items and quantities received match with the products described in the invoice and packing list. ・ This product was checked and carefully packed in the factory. Please contact us if the item arrives damaged. ・ All wiring is to be performed by a qualified electrician. ・ Use only LED Drivers provided by Tokistar with the system. ・ Turn main supply to LED Driver on only after all connections have been made and tested. ・ Do not attempt to disassemble or modify the product, doing so will automatically nullify the warranty. ・ Each LEDs may not emit exact brightness or colour due to LED colour variation at normal operation. ・ Please do not use insulation resistance meter when testing the dimming signal line. It may cause failure to the fixture due to high voltage
CAUTION
This fixture is rated 700mA constant current. DO NOT plug in fixture directly to an AC power supply. This fixture is for INDOOR USE ONLY. Please DO NOT USE in the following conditions and environment ・ Ambient temperature exceeds 40˚C ・ If the relative humidity of room reaches 30%-80%RH, or when moist often occur. ・ locations prone to vibrations and too much dusts. ・ When fixture is subject to exposure to flammable gases or corrosive gases.
※If you want to use the fixture to places mentioned above, please contact us.
(200)
38
21
P/2
GRHB-_-_K-_
GRHB-_-_K-_
GRHB-_-_K-_
■ Parts Name and Dimensions
■PRECAUTIONS
End CapCover Lens
CableAWG20×2(Red +Black−)
L=240~2400
P= Pitch
With side attached adjustable bracket fixture dimensions
With bottom attached adjustablebracket fixture dimensions
Adjustable Mounting Bracket Wall-Mounting Adjustable Bracket
(88) (87) (54)(62) (62) (46)
(65)(51)
(27)
(59)
(42)
(87)
(95)
(119
)
(103
)
(45)
84° 90°
90°
90°90°
90°
55° 55°
Fixed Bracket
(45)
(26)
GRHB-FIXB
GRHB-WMB
・ Fixed Mounting Bracket ・ Adjustable Mounting Bracket ・ Combination with wall mounting adjustable bracket
・ How to attach Align the center of honey comb louvers to the center of lens.
(42)
(48)
● Honey Comb Louver GRHB-HLVR
Honey Comb Louver + Fixed Bracket Honey Comb Louver + Adjustable Bracket Honey Comb Louver + Wall-Mounting Adjustable Bracket
●Seamless Linear Installation
The fixture is designed with spaces that serves as a passage to allow cables to bend sideways or downwards in orderto place fixtures side by side.
GRHB-ADJB
(37)
(121)
(45)
(33)
Make sure to firmly align the lens and the honey comb louvers,not doing so may cause the louvers to slip and fall off.
INSTRUCTION MANUAL
Thank you for choosing TOKISTAR.For your safety, please ensure to observe the following guidelines written in this manual.
Base
With side attached adjustable bracket fixture dimensions
With bottom attached adjustablebracket fixture dimensions
5/6
■PRODUCT CODE■SPECIFICATION ■WIRING
■MOUNTING POSITION
■MOUNTING PROCEDURES
GRHB-75-3000K-SP
Spacing Color Temperature Beam Angle6075
100
60mm75mm100mm
:::
2700K3000K4000K2200K3500K5000K
270030004000220035005000
::::::
:::::
SP15D
8D25D35D
(40°×15°)15°8°25°35°
Rated Current Power
Material
Weight
700mA2.1W / LEDBaseCoverLensEnd cap
※Not for fixed bracket
Minimum Space Requirement
50
50
50
50
●Fixed Holder
GRHB-_-_K-_GRHB-_-_K-_
Please connect the LED constant current power supply, 700mA, +(plus)to red wire、-(minus) to black wirePrior to making the connection, make sure that the main supply is turned off.If you place the fixture too far from the power supply, it will not light up properly.The fixture will give a different output than normal if distance from the DC power supply to the fixture exceeds the recommended maximum length due to voltage drop.Note that One (1) is to (1) ratio of driver and fixture required.
WARNING
・ Turn off electricity before beginning installation or any wire connections. ・ After turning off the power supply please wait for not less than a minute before re-powering.
・ One LED Driver per fixture is required. ・ Parallel connection from power supply is not permissible. ・ Do not connect directly to AC power supply
Distance from power supply chart
:Aluminium(Black Anodized):Aluminium(Black Anodized)::
PC / PMMAPC(Black)
(Acrylic)
approx. 650~1250g / m(without the optional parts)
Bracket Guide
※ Optional parts are sold separately
LDCC-__W-700AWG200.5sq
AWG180.75sq
within 50m
within 100m
(with fixed bracket)
LDCC-_W-700***
AC
Fixtures are not to be wired in parallel
CAUTION
Before screwing the fixed bracket, make sure that the Bracket Guide sticker behind the fixture is aligned to where fixed bracket will be screwed.
Securely attach Mounting Brackets with screws, and then snap the Gradient Extrusion in place.
●LDCC-_W-700 Power Supply Maximum Load per fixture and Configuration
Using One (1) Channel , Fixture can handle 1 up to 15 pieces of LEDs.
Using Two (2) Channels , Fixture can handle up to 16-20 pieces of LEDs.
+ RED - BLACK
LED 2
LED 2
LED 1
LED 1
-
+
-
+
GREEN
WHITEBLACK
RED
●ADJUSTABLE BRACKET
Bracket Guide
・ Adjustable Brackets can be attached on either side of the fixture or at the bottom.
・ Adjust the fixture to its maximum pivotal range then secure one side with a screw. Hold the fixture tightly to its place then secure the other screw. For safety, please make sure to secure both ends with screws.
3/6
GRHB-_-_K-_
Slide in fixed brackets into T-Slots located atthe end of the fixture.
Attach the adjustable brackets in alignmentwith the bracket guide sticker.
Make sure the screwsare not protruding.
■ADJUSTABLE BRACKET WITH LOUVER
4/6
GRHB-_-_K-_
(42)
(32)
(53)
(41)
(123)
(121)
(37)
(74)
Glare Cut Louver + Adjustable Bracket Glare Cut Louver + Wall Mounting Adjustable BracketLouvers can be attached on either side.
Slide in the Louver at T-Slot Secure using the supplied screws.
●GLARE CUT LOUVER
●PARALLEL LOUVER
GRHB-GLVR
GRHB-PLVR
Louvers can be attached on either side. Snap one side first, then snapthe other side.
Make sure that the holes of the louver are aligned with the lenses.
To remove the louver, use a minus screw driver.
(65)
(70)
(45) (45)
(86)
Parallel Louver + Fixed Bracket Parallel Louver + Wall-mounting Adjustable Bracket
Parallel Louver + Adjustable Bracket